Home
Quick Start Guide
Contents
1. Equipments with communication RF radio frequency might affect the monitor performance Do not stretch twist or kink the cables Follow the specific legislation with regard to the monitor use in aircrafts as It works via handy network Remove the battery if monitor shall not be used for more than 15 days Do remove or exchange the GSM chip SIM delivered with the instrument The monitor is not recommended for the use in sport activities or which require intense physical efforts The use of the monitor in case of artificial pacemaker users should be prescribed and accompanied my medical professionals As the Nexcor monitor operates via the use of the handy network in case of the concomitant use with a pacemaker the restrictions determined by the pacemaker manufacturer should be duly observed The USB monitor entry located at the higher level is for manufacturer s use only and should not be used for another purpose POSSIBLE WORKING PROBLEMS AND SOLUTIONS Problem Monitor does not turn on Blue Led remains on for more than 10 seconds Possible Solution Verify if the battery is correctly inserted Verify if the battery 15 loaded Verify if the electrode plugs are correctly connected to the electrodes Verify the electrodes and perform the exchange if they are peeling away Verify if the cable or plugs show some average and request the exchange Discon
2. QUICK GUIDE nexcor NEXCOR Cardiac Monitor Model NX3L List of Sym 02 Precautions Site ee ese N NTE __ 03 RESUIiICTIONS 67 OM 04 Possible working problems and 5 1 06 ane ee ee re er eee eee 07 Battery load indication deans Seereddinadnaesapesahebd and ts 08 batery Wadih 09 Battery insertion 09 eeeipcatdone decece sree acy ete 10 ONC Sea 12 The 13 Cable connection to the electrodes 15 LIST OF SYMBOL Manual Equipment Symbology ATTENTION IDENTIFIES CONDITIONS OR ACTIONS ie WHICH NEED HIGHER ATTENTION ON THE PART OF TRE USER WARNING IDENTIFIES CONDITIONS OR PRACTICES WHICH MIGHT PUT EQUIPMENT AT RISK NOT PROTECTED CLASS AGAINST DEFIBRILLATOR EQUIPMENT ELECTROMAGNETIC RADIATION LOW BATTERY MONITOR ON OR ELECTRODE NOT OFF CONNECTED MONITORING HANDY SIGNAL CENTRAL CALLING INTENSITY BUTTON D MICROPHONE VOLUME CONTROL PROTECT AGAINST RAIN AND HUMIDITY HUMIDITY LEVEL TEMPERATURE yo LIMITS NOT EXPOSE TO SUN 2 o T PRECAUTIONS CUIDADO Whenever using the monitor verify the proper operation form follo
3. are essential to allow the NEXCOR to capture the heart electrical impulses The electrodes should be substituted every day or whenever the user takes a bath Before the bath remove the electrodes and after the bath insert new electrodes careful to substitute the electrodes when they show low adherence to the skin The low adherence might be caused by transpiration or by the natural skin oiliness IMPORTANT It is normal that men have hair on the thorax on the places where the electrodes should be positioned The hair generates interference in the electric impulse capturing and this fact impairs or even prevents the generation of electrocardiograms Thus if this is your case shave the hair at the places where the electrodes shall be placed on CABLE CONNECTION THE ELECTRODES Install an electrode in each one of the four cable connectors as shown in the image above Position the electrode pin into the central hole of the connector until hearing the electrode locking into the connector IMPORTANT The NEXCOR 15 a monitoring device The diagnosis on the health condition of the user should always be provided by a specialized physician and with the use of all means and equipment which are appropriate for mentioned purpose CO RCAM 2 NEXCOR Manufactured and Distributed 3 Tecnologia under the license of Corcam Tecnologia S A www nexcor com br Rua Sampaio Viana 202 conjs 104 105 Parai
4. Close the cap as shown below BELT USE The belt should be used as follows 1 INTRODUCE THE RIGHT ARM AND THE HEAD IN THE CLOSED STRAP 2 ADJUST THE WAISTBAND AND TIE THE FASTENERS 3 PUT THE MONITOR INTO THE POCKET WITH THE BUTTON IN THE FORWARD AND THE CABLES IN THE UPWARD POSITION 4 PASS 3 OF THE 4 ELECTRODES THROUGH THE WAIST ELASTIC BELTS 5 PASS 2 OF THE 4 ELECTRODES THROUGH THE STRAP BELTS OF THE HOLDER MONITOR USE Your NEXCOR should be used as follows To turn on the NEXCOR press the turn on button until the orange light gets on see the images indicating that the NEXCOR 15 Orange Led THE ELECTRODES The electrodes should always keep a direct contact to the skin and should be positioned as follows RIGHT SIDE RED YELLOW RED The electrode should be positioned on the Superior RIGHT part of the thorax just below the clavicle bone YELLOW To be connected to the electrode which should be positioned on the superior LEFT side of the thorax just below the clavicle bone BLACK To be connected to the electrode which should be positioned on the inferior RIGHT side of the thorax just below the last rib GREEN To be connected to the electrode which should be positioned in the inferior LEFT side of the thorax just below the last rib 13 The correct electrode positioning as well as the direct contact of the electrodes to the skin
5. nect and reconnect the monitor with connected cable and plugs Problem Possible Solution Nexcor vibrates and the yellow Led remains on Substitute the battery for another fully charged battery Green Led 15 off Verify its location and look for and monitor issues the place that presents the a sonorous signal best GSM Handy from time to time Network connection Calling signal Use the volume control Speaking tone bottoms for a more is too low proper volume BATTERY LOADING The battery type is of NEXCOR BPAL The external loader MODEL is 3J NX3LC 7 BATTERY LOAD INDICATION The NEXCOR has a battery level indicator which alerts user whenever the battery should be reloaded Yellow Led When the battery reaches 30 of the load the NEXCOR vibrates and the yellow led shall blink When the load is 10 or less the yellow led shall remain on to alert user on the battery exchange need The user should stay alert to be sure that the battery 15 always loaded and that a loaded exchange battery Is always ready to perform the substitution BATTERY LOADING To load the battery insert it the external loader as shown in the image below Connection Entry BATTERY INSERTION IN MONITOR To insert the battery into the instrument press the button that opens the battery cap and remove it Install the battery following the battery and monitor indication arrows
6. so Sao Paulo SP CEP 04004 000 11 3294 7667 3294 7671
7. wing all user manual determinations The monitor cannot operate properly stored or used under circumstances beyond the ambit declared in the manual or if it is submitted to shocks or falls Make sure that the battery 15 correctly inserted into the equipment Check the cable and electrode connectors before use and If some evident damage 15 stated contact the manufacturer Use the monitor preferably with the support belt To send the data and information collected during the monitoring the monitor needs access to the GSM Handy Network To guarantee a precise performance and avoid device failure do not let the monitor enter in contact with liquids or be exposed to extreme humidity he device might not be used in contact with water as for example rain bath swimming pool or seawater The monitor cleaning should be performed daily after its use with a clean and dry cloth oWith the use of safety belts in vehicles take care to avoid that any pressure 15 exercised on the monitor or on the electrodes WARNING The monitor cabinet should only be removed by a qualified service staff Except to the battery there are no Internal parts to be selected by user RESTRICTIONS Attention Equipment is not compatible for the use together with a defibrillator The device should not be used close to equipment that issues electromagnetic or high frequency signals for instance chirurgical equipments 4
Download Pdf Manuals
Related Search
Related Contents
Builders Edge 130110008048 Installation Guide 707 Tablet Pump troubleshooting river pumps and bore pumps W28 Mode d`emploi de DynamiCompta Bedienungsanleitung Lasermikrometer TLSM Oregon Scientific DS6300 User's Manual SI5010 MANUAL DE INSTALACION SMS alarm controller User manual Copyright © All rights reserved.