Home

Brightfield LED LDB100/LDB101

image

Contents

1. 3 Connect a BNC BNC cable to the TTL port on the LED Head and the other end to the TTL socket on the LDBUSBTTL Connect the USB Type B cable to the LDBUSBTTL and the other to a free USB slot on your PC The LDBUSBTTL may need to have drivers installed for it to be recognised b y the PC See section 3 6 Connecting a LDBUSBTLL to a PC Turn on mains switch to give power to the LED Head and Intensity Control Pot On Off button on the Intensity Control Pot Assembly maintains the on or off condition before and after the cycling of mains power The Power Indicator LED see fig 5 will be lit if the toggle switch is in the ON position If the mains power is on and the Power Indicator LED is not illuminated please press the ON OFF toggle switch make the control pot active Use the Intensity Control Pot to set the light levels required Power Indicator Intensity Control Wheel ON OFF Toggle Switch 10 LDB100 LDB101 Fig 5 Intensity Control Pot T Micro p e e e e e 5 24V Power Supply Microscope Adapter LED Head BNC to BNC ies Intensity Control Pot To Mains power supply TTL to USB USB Cable type B BNC to BNC cable System Diagram 3 LDB101 incl Prior LDBUSBTIL Brightfield LED powered directly from mains supply with software Intensity Control Pot control via LDBUSBTLL The Prior LDB100 101 will fit Nikon Ti 80i 90i microscopes without the need for a microscope adapter
2. On Off button on the Intensity Control Pot Assembly maintains the on or off condition before and after the cycling of mains power The Power Indicator LED see fig 4 will be lit if the toggle switch is in the ON position If the mains power is on and the Power Indicator LED is not illuminated please press the ON OFF toggle switch make the control pot active e Use the Intensity Control Pot to set the light levels required Fig 4 Intensity Control Pot 8 LDB100 LDB101 Microscope Adapter LED Head Microscope Intensity Control Pot USB Cable type B or RS2332 Prior Shutter Cable a gps Prior Controller System Diagram 2 LDB 100 Brightfield LED powered from the Prior controller Software control via shutter commands of Prior controller The Prior LDB100 101 will fit Nikon Ti 80i 90i microscopes without the need for a microscope adapter LDB100 LDB101 3 3 The Brightfield LED with a Prior LDBUSBTTL converter Using this set up allows for either manual control of the LED via the intensity control pot or via software control through the LDB USBTTL converter The LDBUSBTTL emulates a Prior Proscan controller with 1 shutter port Through software control the LED can be turned on and off via the standard Prior shutter commands LED illumination intensity can not be adjusted via software control 3 3 1 Installation Connect Intensity Control Pot to the socket on the LED Head See system Diag
3. Prior office SECTION 7 TECHNICAL SPECIFICATIONS Relative Spectral Distribution T T T T T T T 450 500 550 600 650 700 750 800 Wavelength TTL Switching time for Brightfield LED 100usec lolx Ag File Edit Settings view Window Help 18 x HOC ENEN x1 vlalssv peza vlelzev fpei gt a v y a 5 2 0 4 1 6 3 1 2 2 0 8 1 0 4 0 i 0 0 i 0 4 2 0 8 3 le A 16 2o0 150 100 50 0 50 100 150 200 250 300 is 30Nov2011 16 20 Running Trigger Auto f chA Rising v 1353 j 20 LDB100 LDB101 SECTION 8 RETURNS AND REPAIRS Should you experience problems with your LumenLED System and want to send it back for service warranty or otherwise a Return Material Authorisation RMA number must be obtained from the appropriate Prior Scientific office before returning any equipment For North and South America contact Prior Scientific Inc for Japan contact Prior KK for Germany Austria and Switzerland contact Prior GmbH and for the all other countries contact Prior Scientific Instruments Limited on the telephone numbers shown below Prior Scientific Instruments Ltd Prior Scientific Inc Prior Scientific GmbH Unit 4 80 Reservoir Park Drive Wildenbruchstr 15 Wilbraham Road Rockland D 07745 Fulbourn MA 02370 1062 Jena Cambridge USA GERMANY ENGLAND Tel 781 878 8442 Tel 49 0 3641 675 650 CB1 5ET Fax 781 878 8736 Fax 44 0 3641 675 651 Tel 01223 881711 e
4. Brightfield LED LDB100 LDB 101 Manual Version 1 01 Table of Contents SECTION 1 IMPORTANT SAFETY INFORMATION 1 1 IMPORTANT SAFETY INFORMATION SECTION 2 IDENTIFYING YOUR SYSTEM 21 Identifying the parts of the LDB100 System 2 3 Identifying the parts of the LDBIOI System SECTION 3 WORKING YOUR SYSTEM 3 1 The Brightfield LED as a Stand alone lightsource 311 Installation 3 2 Identifying the parts of the LDBI O1 System 3 2 1 Installation 3 3 The Brightfield LED with a Prior LDBUSBTTL converter 3 3 1 Installation 3 4 Adjustments to the Brightfield LED 3 5 Changing the Microscope Adapter 3 6 Connecting a LDBUSBTTL to a PC 3 6 1 Installing the LDBUSBTTL in Windows 7 3 6 2 Installing the LDBUSBTTL in Windows XP SECTION 4 SOFTWARE COMMANDS SECTION 5 REPLACEMENT amp SPARE PARTS SECTION 6 SERVICING SECTION 7 TECHNICAL SPECIFICATIONS SECTION 8 RETURNS AND REPAIRS MH AK 17 19 20 20 21 LDB100 LDB101 SECTION 1 IMPORTANT SAFETY INFORMATION SAFETY WARNINGS Always observe the following safety precautions e Before using the illumination system please follow and adhere to all warnings safety and operating instructions located on the product and in this User Manual e Use only as specified by these operating instructions or the intrinsic protection provided by the unit may be impaired e It is safe for use in an ambient temperature from 5 to 40 C with relative humidity to 80 up to 31 C decreasing l
5. LDB100 LDB101 11 3 4 Adjustments to Brightfield LED The Brightfield LED can be adjusted to obtain an even illumination Direction of Adjustment Fig 6 Intensity Control Pot 1 Turnon LED 2 Loosen the Locking Screw 3 Move the lead head back and forth along the direction of travel as indicated in Fig 6 Until you achieve an even illumination 4 Tighten the Locking Screw 12 LDB100 LDB101 35 Changing the Microscope Adapter Fig 7 Intensity Control Pot 1 Loosen the 3 fixing screw 2 Remove adapter and replace with new adapter 3 Tighten the 3 fixing screws 3 6 Connecting a LDBUSBTTL to a PC 13 LDB100 LDB101 The LDBUSBTTL will emulate a Prior Proscan controller with one shutter connected and can be set up in 3 party software this way LDBUSBTTL may require a driver to be installed if so then please go the following section on the Prior Scientific website and download PL200 ES10ZE USB Drivers http ww w prior com do wnloadcentre dc_softw are html 3 6 1 Installing the LDBUSBTTL in Windows 7 Plug in the USB cable to the LDBUSBTTL and the computer Windows 7 should automatically recognize the device and install the appropriate drivers 3 6 2 Installing the LDBUSBTTL in Windows XP Plug in the USB cable to the LDBUSB TTL and the computer When prompted select No not at this time then click NEXT Found New Hardware Wizard Welcome to the Found New Hardw
6. are Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only OY w and every time connect a device Click Next to continue Fig 8 14 LDB100 LDB101 Select Install from a list or specific location advanced Found New Hardware Wizard This wizard helps you install software for USB Serial Converter If your hardware came with an installation CD ZE or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Click Next to continue Fig 9 Browse to the location of Eval232R click NEXT Browse For Folder Select the folder that contains drivers For your hardware My Documents 5 4 My Computer Se VAIO C Documentation Search removable media floppy CD ROM B O Documents and Settings Include this location in the search Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed bb j ml Drivers i C Documents and Settings v C Audio Bluetooth Camera 5 Chipset Choose this option to select the device driver from a list Windows does not guarantee that z pse the driver yo
7. e control pot active e Use the Intensity Control Pot to set the light levels required Power Indicator ON OFF Toggle Switch Intensity Control Wheel Fig 3 Intensity Control Pot 6 LDB100 LDB101 Microscope Adapter LED Head pam an SS 0 24V Power Supply Microscope dm m To Mains Intensity Control Pot power supply e nnn 24V Power Supply System Diagram 1 LDB101 Brightfield LED powered directly from mains supply Use this set up for manual control only Intensity Control Pot The Prior LDB100 101 will fit Nikon Ti 80i 90i microscopes without the need for a microscope adapter LDB100 LDB101 3 2 The Brightfield LED witha Prior controller Proscan or Optiscan Using this set up allows for either manual control of the LED via the intensity control pot or via software control through the Prior controller Through software control the LED can be turned on and off via the standard Prior shutter commands LED illumination intensity can not be adjusted via software control 3 2 1 Installation e Connect Intensity Control Pot to the socket on the LED Head See system Diag 2 e Connect one end the Prior shutter cable the socket on the LED Head and the other end to and available Shutter port on the back of the controller Make a note of the shutter port for use in any software control of the system e Turn on Prior controller to give power to the LED Head and Intensity Control Pot
8. id the warranty This product does not contain consumer serviceable components Service should be performed by Authorised Service Centres 2 LDB100 LDB101 e Only the exterior of this product should be cleaned using a damp lint free cloth A This warning symbol indicates that the surface may be hot Save this manual as it contains important safety information and operating Instructions 3 LDB100 LDB101 SECTION 2 IDENTIFYING YOUR SYSTEM There are two variants to the Prior Brightfield LED system The LDB100 system is powered directly froma Prior controller OptiScan or ProScan with active shutter connectors The power and control are provided by the shutter cable from the Prior controller to the LED Body You must have a Prior controller to use this version of the Brightfield LED The LDB101 comes witha stand alone power supply this allows the unit to be operated with out the need of a Prior controller The unit is powered directly from the mains supply This version can be used without the need for a Prior controller NOTE It is important to connect all parts before powering on the units 2 1 Identifying the parts of the LDB100 System The LDB100 consists of 1 off Main LED body 1 off Microscope Adapter 1 off Intensity Control Pot 1 off Prior Shutter cable Fig 1 LDB100 Microscope Adapter Shutter Cable L SS LED Body Intensity Control Pot 4 LDB100 LDB101 2 2 Identifying the parts of the LDB101 Sys
9. inearly to 50 rH at 40 C e Do not expose the product to water or moisture while energised e Do not allow moisture to penetrate openings in the case If this occurs allow the unit to dry out unpowered before switching on again e Do not expose the product to extreme hot or cold temperatures e Do not expose the product to open flames e Do not allow objects to fall on or liquids to spill on the product e Do not replace detachable mains supply cords by inadequately rated cords e Do not cover or impede ventilation to this system e Do not stare into the light output of the LED units e Connect the AC power cord only to designated power sources as marked on the product e Make sure the electrical cord is located so that it will not be subject to damage e Make sure the system in installed so that the reaer panel power switch is easily accessible e For use ina manner not specified in this manual contact Prior before any work is done e To reduce the risk of damage unplug the product from the power source before connecting the components to gether e DANGER never alter the AC cord or plug If the plug will not fit into the outlet have a proper outlet installed by a qualified electrician e Only suitably rated and approved mains cord sets should be used as per the country of use e Use only the proper type of power supply cord set provided with the system for this unit e Do not attempt to disassemble the product Doing so will vo
10. mail info prior com email jena prior com Fax 01223 881710 email uksales prior com Prior Scientific KK Kayabacho 3 Nagaoka Bldg 10F 2 7 10 Nihonbashi Kayabacho Chuo Ku Tokyo 103 0025 JAPAN Tel 81 0 35652 8831 Fax 81 0 3 5652 8832 email info japan prior com 21 LDB100 LDB101
11. oller e g DRIVE CHIPS 10011 means Z and 4th axis chips missing SHUTTERS 110 means shutter 1 not connected The final line of information is always a line saying END This allows for the addition of extra fields of information without effecting application software Users should always read lines in until the END is seen A typical response is shown below PROSCAN INFORMATION DSP_1 IS 4 AXIS STEPPER VERSION 2 7 DSP_2 IS 2 AXIS STEPPER VERSION 2 7 DRIVE CHIPS 010111 F2 Fl AZ Y X 0 Not Fitted JOYSTICK ACTIVE STAGE H101 2 FOCUS NORMAL FILTER 1 NONE FILTER_2 HF110 10 SHUTTERS 001 S3 S2 S1 0 Not Fitted AUTOFOCUS FITTED VIDEO NONE END Turns on or off the LED s value 1 2 or 3 LED is not Ifc 0 the LED is on fitted E 20 will If c 1 the LED is off be returned Cc Returned the status c of the LED s If LED is not fitted E 20 will be returned Shutter s Prints information about LED s The information end is always a line saying END This allows for the addition of extra fields of information without effecting application software Users should always read lines until the END is seen in order to maintain compatibility Example SHUTTER_1 NORMAL DEFAULT_STATE CLOSED END 17 LDB100 LDB101 You can use the following commands if connected via the Prior LDBUSBTTL None Text String Text String R If LED is not fitted E 20 will be returned c If LED is not fit
12. ted E 20 will be returned Reports information about the peripherals currently connected to the controller The information end is always a line saying END This allows for the addition of extra fields of information without effecting application software Users should always read lines in until the END is seen A typical response from LDBUSBTTL is shown below PROSCAN INFORMATION DSP_1 IS NOT FITTED DSP_2 IS 3 AXIS STEPPER VERSION 0 0 DRIVE CHIPS 111000 JOYSTICK NOT FITTED STAGE NONE FOCUS NONE FOURTH NONE FILTER_1 NONE FILTER_2 NONE SHUTTERS 001 LED 0000 AUTOFOCUS NONE VIDEO NONE HARDWARE REV A END Returns the version of the code fitted to the unit Eg USBTTLinterface V 1 3 Turns on or off the LED s value 1 If c 0 the LED is on If c 1 the LED is off Returned the status c of the LED s 18 LDB100 LDB101 SECTION 5 REPLACEMENT amp SPARE PARTS W2288 Shutter Cable W4114 24Volt Power Supply LM317 Intensity Control Pot Microscope Adapters LM685 Olympus Microscope Adapter LM686 Leica Microscope Adapter LM687 Zeiss Microscope Adapter The Prior LDB100 101 will fit Nikon Ti 80i 90i microscopes without the need for an additional adapter 19 LDB100 LDB101 SECTION 6 SERVICING This equipment contains no user serviceable parts Refer all repairs to qualified service personnel Opening the product voids the warranty For approved service outlets contact your nearest
13. tem The LDB101 consists of 1 off Main LED body 1 off Microscope Adapter 1 off Intensity Control Pot 1 off 24Volt Power supply amp mains cable Fig 2 LDB101 24V Power Suppl TET Microscope Adapter Intensity Control Pot 5 LDB100 LDB101 SECTION 3 WORKING WITH YOUR SYSTEM The Brightfield LED can be controlled either manually or under software control using 3 party software Both the LDB100 and LDB101 are supplied with a manual intensity control pot Intensity is regulated by turning the dial clock wise to increase intensity and anticlockwise to decrease intensity The LED light can also be turned on and off via and integrated toggle switch on the intensity control pot 3 1 The Brightfield LED as a Stand alone Lightsource This option only allows for manual control of the LED via the Intensity control pot 3 1 1 Installation e Connect Intensity Control Pot to the socket on the LED Head See system Diag 1 e Connect the 24V power supply to the socket on the LED Head and plug in mains cable e Turnon mains switch to give power to the LED Head and Intensity Control Pot On Off button on the Intensity Control Pot Assembly maintains the on or off condition before and after the cycling of mains power The Power Indicator LED see fig 3 will be lit if the toggle switch is in the ON position If the mains power is on and the Power Indicator LED is not illuminated please press the ON OFF toggle switch make th
14. u choose will be the best match for your hardware Don t search will choose the driver to install D e To view any subfolders click a plus sign above mm MED Fig 10 Fig 11 15 LDB100 LDB101 The Eval232R folder can be found in the SDK This can be downloaded from ww w prior com Em 8 04 0020 zip File Edit View Favorites Tools Help Q 22 ed Bs JO search gt gt Folders El Address E C Documents and Settings dhenderson Desktop 8 04 0020 zip Folder Tasks S 2 p oe Extract all files Documents Eval232r Headers PlxDriverS 1 3 PriorIcon ICO PriorIntro exe Readme txt setup exe File and Folder Tasks Move this Folder D Copy this folder X Delete this folder Other Places Desktop My Documents My Network Places Details Eval232r File Folder Date Modified 20 March 2008 10 01 Fig 12 Contents of SDK Found New Hardware Wizard 2 VB Source Autorun inf Fig 13 Click Finish Completing the Found New Hardware Wizard The wizard has finished installing the software for USB Serial Converter Click Finish to close the wizard 16 Cancel LDB100 LDB101 SECTION 4 SOFTWARE COMMANDS You can use the following commands if connected via the Prior controller ProScan or Optiscan The Brightfield LED uses the same command set as the Prior Shutter None Text String Reports information about the peripherals currently connected to the contr

Download Pdf Manuals

image

Related Search

Related Contents

交通安全施設工事成績評定書 - 大阪府電子調達(電子入札)  Series 5 Weld Head User`s Manual (SWS-MANUAL-5HC  Dossier - Collectif Solidarité Contre l`Exclusion  Samsung HT-DS140 Manuel de l'utilisateur  User`s Manual - produktinfo.conrad.com  Topcom SMC-3000 User's Manual  Fujitsu B line B20T-6  Asko D3731 Dishwasher User Manual    GEOHM C Medidor de resistencia contra tierra  