Home
astec user manual - altor security systems
Contents
1. SET DISARM Enter the premises by the entry exit route The entry buzzer will start Press and enter your code The buzzer will stop and DISARMED will be displayed oJ DISARMED PART SET Ensure that all perimeter zones are closed Press Enter your code if requested PARTSET will flash 22 38 no PARTSET KC Xx When PARTSET stops flashing the system will be Part Set Instant FULL SET To set the system silently and without exit time 1 Press CLEAR SET FULL FULL 2 Enter your code if requested SET will flash on the display When SET stops flashing the system will be Set PART SET with exit time no buzzer To part set the system and leave the premises without disturbing the other occupants 1 Press CLEAR SET FART PART 2 Enter your code if requested PARTSET will flash on the display When PARTSET stops flashing the system will be Part Set BELL TEST 1 Press CLEAR Fn 9 2 Enter your code This turns on the strobe light activates the internal sounder for about five seconds activates the external sounder for 5 seconds and finally switches off the strobe BYPASS ZONES 1 Start arming the system and when SET or PARTSET is flashing 2 Press Display prompts for zone number 3 Press zone number Zones that can be bypassed flash on the
2. 4 Press zone type button to focus test on a particular zone e g 5 Test zone 6 Press Buzzer will sound when contacts on zone 2 are opened and closed to terminate the test ZONE INFRARED CONTACT SENSOR TEST gt CHANGE TIME AND DATE 1 Press CLEAR Fn 1 2 Enter your code N 12 06 First digit of time flashes indicating au that it may be changed Nesi 3 Enter all digits of correct time e g 09 22 Digits appear as they are typed 09 22 4 Press BEN l x First digit of date flashes indicating that it may be changed If the date is correct just press DATE 5 Enter all digits of correct date e g 25 12 225 12 s 4 SET 6 Press TX First digit of year flashes indicating that it may be changed If the year is correct just press 19 BB 7 Enter all digits of correct year EH 8 Press CALL CENTRAL STATION 49D amp 63D When the system is disarmed after an alarm the buzzer will sound cA and CALL CENTRAL STATION will be displayed ioi 1 43 Silence the buzzer by pressing Telephone your central station or monitoring company TEST CALL 49D amp 63D 1 Press CLEAR Fn 7 CENTRAL STATION 2 Enter your code 3D ou ns When the test call has been completed the display will show Central Station Contacted Test calls should only be made
3. Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on off 4 Bypass 24 hour zones when system is unset 5 Testing zones chime 5 Change time and date 6 Call Central Station 6 Test Call for digital communicators 49D amp 63D 6 Adding or removing user codes 7 Changing your user code T Smoke Detector Operation 8 Mains failure 8 Alarm memory 8 User Commands 9 Changing telephone numbers for voice diallers 11 Test call for voice diallers 12 Installation Details 14 Copyright 1997 ASTEC LTD All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of ASTEC LTD ASTEC LTD reserves the right to change the contents of this document and the products mentioned herein without notice ASTEC LTD makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose There are patents pending to protect the design of the ASTEC system KEYPAD Four indicators on the keypad communicate information about the alarm system be er POWER Ea POWER 12 55 aur EH Green normally on flashes when the mains
4. To remove a code press now Enter new code OOOO 4 to 6 digits Press i Enter new code 999999 Set Time 8 Date Press ELEAR C Fn J O Enter 00098 Enter the time HAMM Enter the date DOMM Enter the year 0000000 Programme telephone Press CLEAR Fn 8 numbers Enter code no 1 9908 Select phone no D or 4 Press To remove the number press now Enter new number up to 16 digits Press GI Programme follow Press CLEAR Fn 2 Voice dialler me number Enter code no 1 CO OOE Press To remove the number press now Enter new number E to 16 digits Press SEE Make test call Press CLEAR Fn 7 Enter code no 1 OOO Voice dialler Choose number D to 5 is follow me number 10 CHANGING TELEPHONE NUMBERS 49DV amp 63DV The 49DV and 63DV have four main telephone numbers which may be changed as shown below If the dialler has to make a call it will try telephone number 1 first and then numbers 2 3 and 4 until the call is acknowledged or six attempts have been made to each number 1 Press CLEAR Fn 8 4 2 Enter operator code 1 EEL Display flashes centre bar to ask which AO telephone number you want to change 3 Select the telephone number that you wish to programme 1 2 3 or 4 EEL If the telephone number has been programmed it will be displayed 4 Press to enter a new telephone number SET flashes on display indicating that i
5. display ZONE ieRaRen SENSOR 4 Press zone type button 4 or Conte or Sensor Bypassed zones stop flashing BYPASS ZONE ii 5 To bypass more zones go to step 2 p Otherwise do nothing and the system will continue to set SWITCH LIGHTS Lights connected to the alarm system may be switched on and off from the keypad To switch the lights on Press CLEAR VIEW 3 To switch the lights off Press CLEAR VIEW 3 If you switch the lights on and then arm the system the lights will be turned off when the exit buzzer stops BYPASS 24 hour ZONES WHEN SYSTEM IS UNSET 1 Press GEAR En es 2 Enter your code 3 Press zone number Display prompts for zone number Display flashes zones that can be bypassed Zones that are already bypassed appear steady 4 Press Cko or Comme or sexsor Bypassed zones stop flashing 5 To bypass more zones press and go to step 3 BYPASS will flash as a reminder that zones are bypassed To unbypass zones repeat steps 1 to 4 zones that are not bypassed will flash on the display BYPASS ZONE 1 pate vi BYPASS ZONE 9 INFRARED nV CONTACT D SENSOR m BYPASS mal TESTING ZONES CHIME 1 Press LEAR Fn 6 2 Enter your code All alarm zones are in test 3 Press zone number e g Zone 2 Contacts Zone 2 Sensors and Zone 2 Infrared are now in test
6. on the instructions of your alarm installer or monitoring centre ADDING OR REMOVING USER CODES The user who has code no 1 factory set to 4711 may change or remove codes 2 3 and 4 1 Press CLEAR Fn 4 2 Enter user code 1 oe Display prompts for user number 1 3 Press user number 2 3 or 4 e g 3 I in DI CODE flashes to indicate that a new xd Pn code for user 3 may be entered ti To remove a code press now 4 Enter the new code 4 I A bar is displayed for each digit entered cone al 7 SET flashes when the minimum number Set of digits 4 has been entered YN 5 Press SET when the new code has been entered i E TEST flashes T al 6 Verify new code by entering it again viu a II When the new code has been verified MEMORY is displayed briefly A to confirm that the new code for user 3 has been saved CHANGING YOUR USER CODE 4 different user codes may be used to set and disarm the system Each user may change their own code 1 Press CLEAR Fn 3 2 Enter your code CODE L Display prompts for new code 3 Enter your new code JAKI A bar is displayed for each digit entered SET flashes when the minimum number of digits 4 has been entered set 4 Press SET when you have entered your new code n TEST flashes Je D 5 Verify your new code by entering it again MEMORY When you have
7. panel requests it enter your code The first event in memory Time and date This example display shows that the ALARM nemorv G i are displayed here alarm was triggered by a door or ZONE 7 P a window contact on zone 2 at 23 57 al contact g3 571 ra SET i The system was SET USER COMMANDS Disarm Press i Enter OOG Full Set Press Enter OOOE if requested Instant Press CLEAR CSET FULL FULL Full Set Enter OO if requested Part Set Press Enter OO if requested Part Set Press CLEAR SET PART PART with exit time Enter OOOE if requested Bypass zones Start arming system 5 or part set and BYPASS Press zone number Press CED Comor Eso Bypass zones Press CLEAR Fn orrass when disarmed Enter 00DE zone number Press CED Eme or on Show open Press CLEAR VIEW 1 zones Enter OO if requested Show alarm Press CLEAR VIEW 2 memory Enter OOS if requested Test zone Press CLEAR _Fn_ Enter 0998 Test zones Press Bell Test Press ELEAR Fn 9 Enter OOO Switch Lights Press CLEAR VIEW 3 Change own code Press CLEAR C Fn 3 Enter 0000 _ Enter new code D9D9D9DOO 4 to 6 digits Press Enter new code 999999 Change Codes 2 4 Press CLEAR Fn 4 Enter main 0998 Select code D
8. verified your new code MEMORY will be displayed to confirm that your old code has been replaced with the new one Note the system will display no and reject new codes that clash with existing codes 7 SMOKE DETECTOR OPERATION If a smoke detector alarm activation occurs when the system is disarmed the alarm keypad will display the smoke detector s zone number and generate a warning tone ALARM RE If the CLEAR key is pressed within 30 seconds the buzzer will ZONE Tq 10 47 stop and the system will not activate the alarm sounders M If the CLEAR key is NOT pressed within 30 seconds the alarm sounders will be switched on and off at approximately 2 second intervals This feature is intended to reduce the incidence of nuisance alarms caused by cooking fumes Smoke alarms occurring when the system is full set or part set will generate an immediate full alarm MAINS FAILURE Your system may be programmed to sound a warning buzzer if its mains supply is disconnected 23 06 MAINS Silence the buzzer by pressing ALARM MEMORY The alarm memory is a 16 event log used to record alarm events and the time and date at which they occurred The alarm memory is displayed automatically when the system is disarmed after an activation Events are shown in the order in which they occurred To review the alarm memory when the panel is unset press CLEAR VIEW 2 and if the
9. accepting a call Description of call for keyholder When you answer the phone you may hear one or two beeps before the message The message will be followed by a tone When the tone stops press the star key on your phone twice The dialler will give a double beep to indicate that it heard the star keys and hang up Note If your system has been set up with two messages the test call will play the second message after the first one has been acknowledged To make a test call 1 Press CLEAR Fn 7 s e CALI 2 Enter user code 1 LN bic The centre bar will flash requesting which number to call 4 Type a number from 1 to 5 5 is the follow me number ba CALL UN The number will be displayed and es the dialler will make the call The progress and result codes that the dialler displays during and after a test call are listed overleaf 12 TEST CALL 49DV amp 63DV As the test call proceeds the progress codes below will be displayed E Checking that the telephone line is present and that there is no incoming ringing a The dialler has gone offhook and is trying to detect dial tone te Dial tone detected now dialler dials the telephone number t3 Number dialled now waiting for telephone to be answered t4 Telephone answered dialler now plays the message and the tone and waits for the person who answered the phone to press the star key twice t5 The star key has been pressed twic
10. ad the new number may be entered EEL J ser 5 Enter the new number i Digits appear on display as they are ressed i Li KEL 6 Press To save the number wa SET The telephone number will be displayed Press to display the number again Press to leave this Remember to make a test call to a new telephone number To delete a telephone number press at step 4 PROGRAMMING THE FOLLOW ME NUMBER The follow me number is a temporary number which is cleared the next time the system is disarmed When the follow me number is programmed the dialler will try it first To programme the follow me number Press CLEAR Fn 2 enter your user code and continue from step 4 above 11 PABX If you have a PABX system it may require a pause between the access number and the telephone number A three second pause may be inserted in the number with the button Example To programme 9 lt pause gt 6704202 press Cser 9 PART 89 0 4 2 00 2 The programmed telephone number will be displayed as 9 P 6 7 0 4 2 0 2 Note If the 3 second pause is entered as the first digit of the telephone number the dialler will dial without waiting for a dial tone which may be necessary on some PABX systems TEST CALL If you do change a telephone number you should make a test call to it to check that the number is correct and to familiarise the keyholder with the message and the procedure for
11. e The call is complete and the dialler hangs up If the test call does not succeed then one of these failure codes will be displayed Fi No dial tone detected The telephone line may be disconnected F2 The call was not answered Check the telephone number F3 The person who answered the phone did not press star button twice after the tone Make sure that the keyholder understands what to do FY Telephone line not detected The telephone line has been disconnected or there is problem with the line F5 Ringing detected on the line Wait until ringing stops or answer the phone F amp Busy tone detected Check the number ring it manually to ensure that it is correct Fi Telephone number number not programmed F8 Dialler is already making a call CALL FAIL 49DV amp 63DV If none of its call attempts is acknowledged by someone pressing the star key twice when they hear the tone the voice dialler will display CALL CALLFAIL when the system is disarmed Note 1 Pressing twice removes CALL FAIL from the display Note 2 The system continues to operate normally 13 INSTALLATION DETAILS Zone Type 14 Installation company Telephone
12. supply is off ALARM ae FAULT ET MM Yellow normally off switched on when De uss the system requires the we attention of an alarm engineer ALARM contact M Red normally off switched on when system is in alarm condition SENSOR CLEAR 006 ET Green switched on when all alarm aenn eas zones are closed and the M lt system is ready to be set DEFINITIONS Full Set Part Set Disarmed Bypass 24hr zone User code When the system is Full Set all the alarm zones are armed and the building is unoccupied When the system is Part Set certain zones are automatically bypassed this allows the building to be occupied with perimeter zones armed When the system is Disarmed alarm zones are switched off but panic buttons fire and tamper zones remain armed Bypassing a zone temporarily removes it from the system the alarm will not activate if a bypassed zone trips Zones may be bypassed when arming the system 24hr zones are always armed safe protection etc Bypassing a 24hr zone gives access to the protected area A4 to 6 digit code used to disarm the system FULL SET Ensure that all zones are closed Press Enter your code if requested SET will flash and the exit buzzer will start Leave the premises by the designated exit route and close the door When the buzzer stops the system will be SET