Use these programming instructions only if the factory

image

Contents

1. PortO settings Port settings Port2 settings Web to Serial Miscellaneous settings Notes Baud Rate can only be set to 9600 or 19200 These are the only two speeds that 1830 Series boards will run at Leave all other settings as shown when the converter is used in the Server Mode Port 0 Settings The current settings for port 0 may be changed using the form below To make the new settings apply each time the S2E module is reset ensure that Save these as next reset default settings is checked before pressing the Submit button If this control is not checked the changes applied to the port but the existing defaults are used whenever the module is next reset a 0 E bits character Stop Bits bit s DOO Ene SESH Hardwarefe ee 1040 Bind local port when TCP Client e TCP Server None Modbus TCP RICERCA 192 168 0 201 N A Timeout seconds lt 256 0 for no timeout reser EE UART packet length EXE chars lt 1024 0 for no use Sine saree FZ olan A Submit Save these as next startup default settings E a G a a Aga cy a a es J ETE E E E ee ee S E E E E E E E E E E IP Address Selection i PROCS CAE Stati
2. Default gateway Use the following DNS server address 10 43 76 198 10 43 76 158 Preferred DNS server Alternate DNS server Ethernet 10M 100M z x gt O 00 E W a LO Z O Q Reload Defaults You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings O Obtain IP address automatically Use the following IP address IP address 192 168 1 5 255 255 255 0 10 43 76 211 Subnet mask Default gateway RS 232 amp 485 To Ethernet DOORKIWN G O Obtain DNS address automatically Use the following DNS server address 10 43 76 198 10 43 76 158 Preferred DNS server Alternate DNS server Accessing the 1830 188 Menus 5 1 Open any browser and type in the address of the CONVERTER http 192 168 1 40 The user Log In window for the CONVERTER will appear Mozilla Firefox File Edit View KOC X Please login User name admin Pass word Histo Bookmarks Tools Help http 192 168 1 40 KKKKEK User name Pass word admin admin The Status and Configuration window will appear on wD You can access settings of the CONVERTER by using the menu at the left in the Status and Configuration screen Only Current config and status PortO settings Port1 settings
3. you must set the IP Address back to the original settings in order to get access back to your network Local Area Connection Properties Unplug the network cable from your PC Using the network cable supplied with the 1830 185 kit plug one end into your PC and the other into the CONVERTER Connect using Intel R 82566DM Gigabit Network C This connection uses the following items Power the CONVERTER with the supplied power supply M cient for Microsoft Networks File and Printer Sharing for Microsoft Networks Macs Packet Scheduler Internet Protocol TCP IP Install Uninstall Properties Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks When completed don t forget to plug the network cable back into the PC and the 1830 188 cable back into the router show icon in notification area when connected Notify me when this connection has limited or no connectivity 0K Cancel Internet protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings O Obtain IP address automatically Use the following IP address IP address 10 43 76 171 255 255 255 0 10 43 76 211 O Obtain DNS address automatically Subnet mask
4. 232 amp 485 To Ethernet RS 232 RS 232 Cable 5 P N 1818 040 6 Ft Cable JE RS232 wire runs limited to 100 Ft Maximum See note above Note RS 232 wire runs are limited to 100 feet maximum If greater distance _ is needed use RS232 to RS422 Extender Kit P N 1830 190 4000 Feet maximum distance ee e ees o E pe Shield n Red Black Green 3 2 5 1 8 7 Brown White RS 232 wire terminal on telephone entry access control system circuit board OORA ODN SKS DOORKIN G system IP Address L Network onnection via LAN Communication Modem RS232 Diagnostics DK IM Server Modem DK IM Server Cellular DK IM Server Client Wait DK IM Server Client Poll Model Number Area Codes Dial First then Network selected in Remote Account Manager Software V6 3 g or later Network Interface Device Hut Ethernet 10M 100M Reload Defaults RS 232 amp 485 To Ethernet
5. DK IM Server Modem DK IM Server Cellular DK IM Server Client Wait DK IM Server Client Poll _ Network Model Number Area Codes Dial First then Network selected in Remote Account Manager Software V6 3 g or higher Network LAN Interface Network Modem Router Interface N I D 1 2 3 4 p Ee ee ee r SJ a Cr lua Ethernet 10M 100M Reload Defaults D ZC p D tu O LO 00 wz o N ae Ba op am P N 1830 181 Rev A 11 14 General Information m _ _ _ _ _ _ _ _ _ _ _ _ ee ee ee M M M M M M M M M ee M 1M M 1M M 1M MM M 1 M Use these instructions when you are using the TCP IP adapter in SERVER MODE If you want to use the TCP IP adapter in CLIENT MODE you must use adapter part number 1830 186 and refer to instruction sheet 1830 182 You can use the 1830 185 Converter Kit with the following DKS Systems 1830 Series Telephone Entry and Access Control Systems 1833 1834 1835 1837 1838 Refer to these instruction manuals for additional information P N 1835 065 Telephone Entry Systems Installation Manual P N 1838 065 Access Controller Installation Manual P N 1835 066 Remote Account Manager Software User Manual i a ae ee Connect Converter to 1830 Series Circuit Board RS 232 Terminals Ethernet 10M 100M Reload Defaults RS
6. Port2 settings Web to Serial Miscellaneous settings 2 Enter the User name and pass word Status and Configuration USR TCP232 E45 192 168 1 40 d8 b0 4c 00 2d f6 selections 1 2 and 6 apply to this module here It is highly recommended that you DO NOT change the password on the authentication screen DoorKing will not be able to assist you if you don t know your ID or password This system status window is informational and there s no need to change anything 1 Remove power from module 2 Press the Reload button and apply power 3 Hold the reload button for 3 seconds then release Module is now reset TCP IP address will be 192 168 1 40 User name and password will be admin All other settings will need to be configured IMPORTANT When you are finished configuring the CONVERTER you must set the Internet Protocol TCP IP Properties screen on your PC back to its original settings in order to get access back to your network Don t forget to plug the netowrk cable back into the PC B m and the CONVERTER cable back into the router FEF E gt Follow the instructions A A get to the Internet Protocol TCP IP Properties screen and then put your old settings pack AY A D J Changing 1830 188 Settings Ooo fr W Current config and status
7. Use these programming instructions only if the factory defaults in the converter need to be changed A B J Connect 1830 188 for Programming The following defaults in the CONVERTER are factory set If they are satisfactory to your system there is no need to change them IP Address 192 168 1 40 Gateway 192 168 1 1 Port 1040 Baud 19200 A If these defaults are not satisfactory navigate to Local Area Connections in Windows Start Control Panel Network Connections Properties Then click Properties to show the Internet Protocol TCP IP Properties Window Highlight Internet Protocal TCP IP Before proceeding write down the numbers or take a screen print in this window You are only going to change the IP Address and you will need to put the same IP Address number back when complete A programming of the CONVERTER is Ex write down the numbers these numbers will not be the same in your computer IP Address 10 43 76 171 Subnet mask 255 255 255 0 Default gateway 10 43 76 211 Preferred DNS server 10 43 76 198 Alternate DNS server 10 43 76 158 A settings Change IP Address to 192 168 1 5 This will allow your PC to connect to the CONVERTER so that you can change its IMPORTANT When you are finished configuring the CONVERTER
8. c IP M 1 Current config and ScWemimaceitcssm 192 168 1 40 status iene 255 255 255 o 2 PortO settings He Peon em 192 168 f 1 3 Port1 settings Update Settings 4 Port2 settings Notes These are the default settings and should be left alone If the static IP address is changed the 5 Web to Serial module will lose communication with the PC You will need to log into the module at the new IP 6 Miscellaneous address using the browser SN a settings Password Settings admin admin Change Password Notes Enter a new user name and password if desired The default user name and password admin admin will restore after the module is reset with the reset button Se tae tess ipa Fee ae el ee E ae a ee General Configuration Settings VOEM USR TCP232 E45 T E 6432 HTTP server port number 80 Module Id use for indentify module Il 1 65535 Module Id type 0 no use 1 send id when connect 2 send id when send data 3 both 0 0 1 2 3 VANIS d8 b04c 00 2d f6 Update Settings Notes All of these settings should be left in the default mode including the HTTP port setting of 80 ay a a E E E E EAN N ya ca rey ees Se J INSTRUCTIONS FOR 1830 185 TCP IP SERVER MODE to RS 232 CONVERTER KIT Connection via INTERNET Communication Modem RS232 Diagnostics