Home
IHS IHSa rev C user
Contents
1. pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE Sealed Lead Acid Battery Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling
2. H ADAM Adam Equipment IHS IHSa SERIES P N 700660189 Revision C November 2012 Software version 1 0 A1 0 Adam Equipment Company 2012 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place Adam Equipment Company 2012 1 0 CONTENTS 1 0 CONTENTS scstacsarccccseouccesaceudicccasusegans cevoncgssbucsenadaudusseabonseiecenecsesavuneenesieess 3 2 0 INTRODUCTION iiieso rei ae en tb ao E E PRX EROR SASUAY EE ra oaae EE T eante a i oe aTa 4 2 1 INTRODUCTION m 4 272 TECHNICAUSPEGIFICATIONS Jesse ere teer vate or iaaa o peu re d aot obe peo aat 5 2 9 SAFETY NOTICE 22 prod ERE REPE P ER SER HERR REPRE AERE NE MERI MA Apa PE DROP ERE EERS 6 2 4 KEY DESCRIPTION iie iere etapas ve redet din saree aaa Sa ah cee dedic peius 7 23 DISPLA P 7 3 0 OPERATION Hume atsara 9 3 SAFETY INSTRUCTIONS cestaasics cesscdedecnsecbtasntanadeilt ads docet adobe oc decode rz eqs che 9 3 2 BALTERY OPERATION osse iei pde n eph peg uana oles ey nn nav at eeu apu pd asi 10 3 3 CHARGING BATTER Yissccasdatniasaresvnsenantns eER x deo naui QE mice E Fe e EAR x cR ESNE B x RENE BERND US 11 spad ueeezies ome 11 S O CALIBRATION niies tana eo eara ee paa me Cru euge Na papse vuRTM He aE anaia e ndr dn dudes 13 5 0 PARAMETER ii ies ceno na hon ee RE
3. ZERO Zero indicator Adam Equipment Company 2012 2 4 KEY DESCRIPTION IHSA VERSION a max 20001b 1000kg x 0 51D 0 2kg EN foe A EMESADAM IHSa Series kg Cr uq o AX VEDO DX N Power Charge EA Hold Ib kg Y On Off Ib kg Hold Zero ON OFF Power switch use this key to turn on and turn off the scale LB KG Unit change key use this key to select the weighing unit of Ib or kg When in setting mode use this key to change parameter HOLD Hold function use this key to lock the display There is a LED indication light on the bottom of the display Press the HOLD key again to cancel HOLD function ZERO Re zero key use this key to return to zero reading 2 5 DISPLAY ZERO Zero indicator CHARGE Charging mode 8 Low battery HOLD Hold mode LB LB weighing mode KG KG weighing mode Adam Equipment Company 2012 3 0 OPERATION 3 1 SAFETY INSTRUCTIONS Read this manual carefully before you operate the IHS Crane Scale Unpack the Crane Scale carefully from the packing Attach it to your hoist or equivalent existing equipment securely at the ground level in the upright position Make sure that the equipment to which the scale is attached is in proper condition The operator should
4. has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2012 ADAM EQUIPMENT is an ISO 9001 2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Health and Fitness retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Adam Equipment Company 2012
5. weight of the calibration mass is measured by the scale Adam Equipment Company 2012 5 0 PARAMETER 5 1 ENTER SETTING MODE Turn off the power of the scale and then turn the power on again Press the CHANGE key during self checking display shows BeeO indicating the scale has entered the setting mode press the HOLD or CHANGE key to shift the parameter items Use ZERO key confirm and escape from setting the current item 5 2 PARAMETER SETTING TABLE FUNCTION DESCRIPTION DEFAULT Sets buzzer 0 Disable 0 1 Enable BEE Sets hold function HoD 0 Disable 0 1 Enable Sets zero function STD STDO zeroing allowed when unstable 0 STD1 zeroing not allowed when unstable Sets auto backlight Only applies when the scale has AUT an LCD display 0 AUTO manual AUTI auto Sets units CHT 0 lb 1 1 kg Sets save 0 not saved 1 save YES Adam Equipment Company 2012 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Equipment Co Ltd Maidstone Road Kingston Milton Keynes MK10 0BD United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device
6. CARENT o EF SF ea eon PAIR EAE EAS EN aena VAS NER iae aao Eta 14 Adam Equipment Company 2012 2 0 INTRODUCTION 2 1 INTRODUCTION The IHS IHSa Series is a range of heavy duty crane scales used to weigh very large masses The main features include Easy Operation amp Rugged construction 30mm super big amp bright red LED display with view angle 360 degree rotary safety hook design easy to use Hold feature Overload safety up to 200 One charge can last 150 hours Auto power off after 30 minutes of non use 7 2Vdc 2 amp battery charger Aluminum die casting housing Large remote control handset Adam Equipment Company 2012 2 2 TECHNICAL SPECIFICATIONS Model No Capacity Division Model No Capacity Division IHS 1 1000kg 0 2kg 0 5kg IHS 2a 20001b 1000kg 0 5Ib 0 2kg IHS 3 3000kg 0 5kg 1kg IHS 6a 6000Ib 3000kg 11b 0 5kg IHS 5 5000kg 1kg 2kg IHS 10a 10000lb 5000kg 2lb 1kg IHS 10 10000kg 2kg 5kg IHS 20a 20000lb 10000kg 5lb 2kg A E Model A B C D E F G Weight IHS 260 203 47 30 628 76 214 12kg 1 2a IHS 260 203 47 30 628 76 214 14kg 3 6a IHS 260 203 60 40 723 80 214 19kg 5 10a IHS 260 203 70 50 837 90 214 31kg 10 20a Adam Equipment Company 2012 2 3 SAFETY NOTICE The limit stated below is the Ultimate Overload Limits of the scales Adam Equipment Co Ltd Its directors owners and affiliated companies and organi
7. NTROLLER A Determine increments in which the weight display B Hold the settled values C Zero the scale D Backlight only used on scales with LCD display Adam Equipment Company 2012 4 0 CALIBRATION Pressing ZERO when scale is power on The display on the scale will show SPAN Make sure the hook is empty Depress the ZERO button the display on the scale will show 00000 after stable After few seconds zero calibration is now complete After zero calibration display shows a value of mass for span calibration you can change the weight by using the CHANGE key to move the active digit flashing and the HOLD key to increment a digit Press the CHANGE to confirm For example the display on the IHS will display 3000 0 3000 0 is the number you have entered using the keys as above Add the calibrated mass that is the same as the value displayed on the hook it the best that the mass is close to the capacity where possible When the scale is stable press the ZERO The display shows HOLD After a few seconds the calibration is complete To calibrate in Lbs make sure that the scale is Lbs mode before commencing to calibrate in Kg make sure the scale is in Kg mode before commencing When using slings chains or other material to support the calibration mass these items should be hung from the scale before setting the zero point so that when the calibration mass is added only the
8. atically power down after 30 minutes of non use to further protect the battery Note More frequent charging of the battery prolongs its life Adam Equipment Company 2012 3 3 CHARGING BATTERY e Plug the power supply into the mains power then into the back of the IHS scale e The red indicator lamp will illuminate to indicate that the battery charger is functioning properly e The green indicator lamp will illuminate to indicate that the battery fully charged 3 4 BASIC OPERATIONS Power on and off Press ON OFF key to turn on the scale Then the display on the scale will show 88888 Press again to turn off the scale Zero the scale Depress the Zero to re zero the reading Change division you can use the CHANGE key to change division Lb kg you use this to select either Ib or kg weighing units HOLD when required such as when the reading is not stable or you cannot pause to record a reading you can use the HOLD key to lock the reading so that you can read it easily later after you finish reading press HOLD again to return to normal weighing mode Note The HOLD key has no affect if the Hold parameter has been disabled See section 5 1 Adam Equipment Company 2012 Overload Warning please do not add any item that exceeds the maximum capacity of the scale When the buzzer is sounded and the display shows remove the item to avoid damage to the load cell and scale 3 5 REMOTE CO
9. be trained for its safe operation Carry out regular visual inspection for any damage or wear and teat on parts Particularly the split pins at the hook and eyebolts and the inner wall of the hook and all joints should be checked regularly If any damage or wear has taken place replace the parts Do all inspection and maintenance work when the scale is not in use Do not expose the scale to extreme temperatures The operating temperature range is 0 C to 40 C Secure the sample to be weighed in the hook of the scale Ensure that the sprung Safety Lever returns to its resting position which prevents the sample from slipping out of the hook Do not exceed the maximum capacity of the Scale Clean and protect your scale after use Adam Equipment Company 2012 3 2 BATTERY OPERATION e The battery will operate continuously for 150 hours before requiring recharging The scale will alert you when the battery is within 10 hours of requiring recharging by the indicator lamp above the low battery symbol to indicate that the battery is low voltage e When the battery requires charging the scale will turn off to prevent battery damage If the button is depressed at this point the indicator lamp will reappear and then the scale will again deactivate automatically e Charging time for a completely discharged battery is approximately 16 hours A full battery pack is recommended to keep the scale continuously operational e The scale will autom
10. sations cannot be held liable for any resulting damage or injury sustained as a result of the machines being used in excess of their stated capacities or ultimate overload limits Model NO IHS 1 IHS 2a IHS 3 IHS 6a IHS 5 IHS 10a IHS 10 IHS 20a Max 1000kg 2000Ib 3000kg 6000lb 5000kg 10000lb 10000kg 20000Ib capacity Overload 1500kg 3000lb 4500kg 9000lb 7500kg 15000lb 15000kg 30000lb capacity NOTICE Do not use the scales if any parts are bent or loose or show signs of damage or wear Refer to the user manual Adam Equipment Company 2012 2 4 KEY DESCRIPTION IHS VERSION Ae Max 5000kg dz1kg 2kg E S EEZADAM IHS Series kg MEC Q Q Q Power Charge EA Hold zero _ On Off Change Hold Zero ON OFF Power switch use this key to turn on and turn off the scale CHANGE Division change key use this key to change division When in setting mode use this key to change parameter HOLD Hold function use this key to lock the display There is a LED indication light on the bottom of the display Press the HOLD key again to cancel HOLD function ZERO Re zero key use this key to return to zero reading 2 5 DISPLAY POWER Power on mode CHARGE Charging mode 8 Low battery HOLD Hold mode