Home

IntenZ CB-150 RGB COB LED Matrix bar User manual - Bax

image

Contents

1. 3 channel mode For advanced setup users may prefer to control each pixel in detail by using the 15 or 18 channel mode SLND When using the master slave function you need to connect 2 or more fixtures with XLR XLR cable The first fixture in line needs to be set as master the others as Slave 1 or 2 synchronized or mirrored performance This way the slaves will mimic the behavior of the master fixture for wonderful synchronized lighting shows SHND Auto mode Select one of the internal programs and set the speed correctly for the best effects SOUN Activate or disable the built in sound controlled mode This way the fixture will respond to the beat of the music SENE The sensitivity of the built in microphone is adjustable to optimize the built in sound controlled mode For example when your music source speakers are placed far away you might want to increase the sensitivity to make sure that the fixture responds to the sound accurately BALA When using several fixtures it might be possible that you want to optimize the colour temperature when using full output white created by RGB 100 output Some people prefer white with a slight blueish tone others prefer warm white to mimic traditional light bulbs Every separate colour can be changed dimmed to achieve perfect white balance when projecting full white in normal mode BLND Black out mode S L S The Signal Loss Setting provides the right action when the fixture s
2. The 3 head Color 000 255 The 4 head Color 000 255 The 5 head Color 7CH Mode The 1 head Color The 2 head Color The 4 head Color The 5 head Color 15CH Mode CH1 CH4 CH7 CH10 CH13 000 255 Red 1 2 3 4 5 CH2 GHS CH8 CH11 CH14_ 000 255 Green 1 2 3 4 5 CH3 CH6 CH9 CH12 CH15_ 000 255 Blue 1 2 3 4 5 18CH Mode CH1 CH4 CH7 CH10 CH13 000 255 Red 1 2 3 4 5 CH2 CH5 CH8 CH 11 CH14 000 255 Green 1 2 3 4 5 CH3 CH6 CH9 CH1T2 CH15 000 255 Blue 1 2 3 4 5 CH16 000 255 CH17 000 255 CH18 000 255 Technical specifications Powerful COB RGB LED technology Classic reflector look Modern LED technology Equipped with 5x 30 Watt COB RGB LED chips Perfect colour mixing thanks to close diode placement and optimized reflector technology Intense and colourful beams Fluent dimming 0 100 for each colour Individual pixel control 1 M S Intenz Matrix System ready Combine multiple devices for large scale matrix or array setups Built in microphone for music controlled operation Menu display and buttons for easy adjustment of settings Adjustable colour temperature L S Signal Loss Setting Blackout or sound controlled mode when no DMX signal is detected DMX operation 1 3 5 7 15 or 18 channels 1 T M Intelligent Temperature Monitoring reduces light output to prevent overheating and controls the fan speed Suitable for use as wall washer blinder stro
3. Six IntenZ CB 150 RGB COB LED Matrix bar User manual Safety instructions A WARNING A Always keep this device away from moisture and rain Hazardous electrical shocks may occur A WARNING A Only connect this device to a matching power outlet This device is intended to work on a specified AC currency Connecting this device to power outlets with other voltages may result in permanent damage and possible hazardous situations such as fire or electrical shocks A WARNING A Be careful with every operation of this device Touching live wires inside and outside the unit may cause hazardous electrical shocks This unit must be operated by or under the supervision of an adult This device is not suitable for children Every person involved with the installation operation and maintenance of this device has to Be qualified Follow the instructions of this manual Make sure there is no damage caused by transport If the device seems damaged from the outside do not use it and contact your dealer for more information and consultation To make sure the device maintains in perfect condition and for safe operation it is necessary for the user to follow the instructions and warning notes of this user manual Damage caused by improper use or modifications to the device are not covered by warranty This device does not have any user serviceable parts inside Servicing of this device needs to be done by qualified technici
4. ans Important notes regarding safety and health Never let the power cord come in contact with other cables Handle the power cord and all connectors with the mains with caution Never remove any warning or informative labels from the unit The ground contact always needs to be connected Do not cover or remove the ground contact Never leave cables lying around Do not open the device and do not modify any hard or software of this unit Do not insert this object into air vents Do not connect this device to a dimmerpack Do not switch the system on and off frequently as this will reduce the lifespan of the device Do not drive the inputs of the fixture with a signal larger than required to work at full performance Only use this device indoor avoid contact with water moist or other liquids Do not place items filled with liquids on top of the unit Avoid nearby flames or heat sources do not place this device near flammable liquids gas or flammable items Always disconnect the device when it is not in use for a longer period or time when servicing is needed or when the device needs cleaning Only handle the power cord by its connectors Never pull the cable to remove a connector from its socket as this could lead to damage and electrical shocks Always operate this device with a stable AC current Always operate this device with the AC ground wire connected to the electrical system s ground Never
5. be low res visual screen allround club lighting system etc Low power consumption High output Long lifespan Connectors DMX 3p XLR male and female Power Twist lock connector power cable to Schuko included and Twist lock output link Power Voltage AC100 240V 50 60Hz Power consumption 150W Physical Dimensions 620 x 160 x 150 mm without bracket Weight 3 5 kg Connectors and wiring schematics DMX connections Electrical wiring DMX output DMX input ALR mounting socket XLR mounting plug Cable International Brown 1 Ground Blue Neutral 2 Signal i 3 Signal 4 Allows Green 1 Ground 2 Signal 3 Signal
6. ent Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to a power source When you suspect that your unit is broken or damaged contact your local dealer or a certified technician to inspect the unit Beam output Adjustable bracket Bracket tightening knob Rigging hardware Menu display with buttons On board microphone Safety eye DMX input DMX output 10 Ventilation slot 11 Fuse 12 Twist lock Power input 13 Twist lock Power output SONO POD Device overview nr TCAE 7 _ guen N HS a m En Special features The IntenZ CB 150 is equipped with special features which enhance the performance of the fixture and also provide more user convenience I T M Intelligent Temperature Monitoring Temperature controlled fan cooling The internal fan of the unit is temperature controlled which means that the fan will only turn on if needed For theatrical and other applications where fixtures need to be as silent as possible this provides lots of convenience When the fixture is not used in blackout mode or used with low output the fan will not turn on The internal fan will turn on when the temperature sensor detects a temperature between 40 and 60 degrees Celsius At first the fan will turn on in low power mode thus being very silent but still cooling When the unit detects that the temperature has not cha
7. h the value set on 001 The display shows several settings each with the possibility to set several values Use the display and the menu buttons to set preferences change settings and scroll through the menu Enter is used to save a certain setting or preset press Menu for at least 2 seconds to discard the change and return to the main menu The table below shows an explanation for every feature and value display _ Mode O o ADDR DMX address setting A001 A512 CHND Channel mode 1CH 3CH 5CH 7CH 15CH 18CH SLND Master slave mode Master default Slave 1 Slave 2 SOUN Sound controlled mode Sound controlled mode on off SHND Auomode 1 Auto speed 1 9 Show 0 16 SENE Sound sensitivit Sound sensitivity 0 100 BALA White Balance Red 000 255 Green 000 255 Blue 000 255 DISP___ Display inversion __ Display Inversion Idsp dsp _ Hour Using time oflight_ Fixture hours 0 9999 ADDR DMX address setting used to determine the DMX starting channel From this channel on the fixture will respond to values corresponding with the amount of channels that the fixture is occupying For example when you turn the fixture in 3CH mode and set the starting address to value 003 the fixture will respond to channels 3 4 and 5 CHND The channel mode of the fixture makes it possible to use the correct channel mode setting for every application For simple and basic setups users may prefer to use the 1 or
8. hnician when corrosion is found on the fixture Every power or signal chassis connector should be mounted tightly Do not use the device when connectors are loose Do not use the power cord when the cores are visible Contact your dealer for a replacement if needed Avoid the buildup of dust and dirt Clean the exterior of the fixture every month with a dry or damp cloth When using the device intensively the cleaning frequency needs to be increased Fuses The main fuse of this device is to be found on the rear of the device In most cases directly next to the power inlet Only replace a fuse for a new one with the same type and rating Do not use a fuse with a higher or lower rating Do not bridge the fuse with electrical wires aluminum foil as the fuse is used for protection against electrical shocks and short circuit Always mount the fuse cover back to the fuse compartiment Box contents Box contents 1x IntenZ CB 150 fixture 1x power cable 1x XLR XLR signal cable 1x installing bracket 1x metal coupler vertical single use 2x small coupling pin with safety clip 2x large coupling pin with safety clip Unit and accessory inspection Always use the supplied power cable to connect the unit to a power supply If the cable appears broken or has visible damage do not use it If the unit is not going to be used for a longer period of time disconnect it from the power supply and store it in a dust free environm
9. imum of 5 IntenZ CB 150 fixtures can be installed as a vertical array Attach fixtures as shown below Note The small U shaped bracket contains a hole for a clamp or coupler The top fixture must be installed with the U bracket attached the other units can be installed below the first fixture Horizontal array vertical fixtures To make a horizontal array of several IntenZ CB 150 fixtures in vertical mode use the included hardware The small couplers are needed for a vertical array An unlimited amount of fixtures can be attached only if there is a new coupler attachement point available every 4 fixtures 1 fixture with attachement point 3 fixtures without 1 fixture with attachement point Ayra recommends to supply every used fixture with an attachement point for safety reasons Every fixture must be provided with a safety cable regardless of the amount of attachement points are used j J j N j we ee seo EN or Lo EN w w lt so TIIT NOTE Always check the maximum load capacity of the construction you wish to mount the CB 150 fixtures to The maximum load of your construction the maximal spread amount of fixtures you can install Setting up the unit To activate the unit connect the included power supply to the unit and a suitable 230V 50 Hz power outlet The fixture will start up and show the last chosen setting on the display Usually with a new product this is the DMX mode wit
10. nged or even increased the speed of the fan will increase to its maximum level when the temperature reaches 60 degrees Celsius Temperature controlled power limit protection When working in extreme environments especially high temperature environments such as clubs or sunny outdoor festivals it is important for the drivers and LED modules to stay intact and be reliable Therefore the IntenZ CB 150 is equipped with a power drop protection which decreases the LED output when the temperature of the fixture exceeds 60 degrees Celsius For every degree above the 60 degrees limit the output power will be decreased with 5 Temperature controlled protect mode When the temperature of the fixture exceeds 68 degrees Celsius the critical maximum temperature limit is reached and the LED output of the fixture will be shut down automatically A cool down time is applied until the temperature decreases back to 60 degrees Celsius When the temperature of the fixture does not decrease after several shut down actions check the following Is the fan still working Is the fan blocked Is the environment temperature too high Is the fan sucking hot air into its ventilation system Is the fixture too close to other hot objects If you are unable to solve temperature problems shut down the fixture completely and check if the fixture still works when you connect it in a colder area If you have any problems with the functionality of the fixtu
11. re after this check contact your local dealer or a skilled technician to inspect the unit S L S Signal Loss Setting The Signal Loss Setting system can be used to program a secondary working mode when the DMX mode fails for example due to a loose cable The secondary mode is set to Black out mode in default which shuts down the output of the fixture until a proper DMX signal is detected By switching off the Black out mode the fixture will turn to sound controlled operation when DMX signal is lost In most situations the Black out mode is used for professional environments which prevents mismatching colours and chases and Sound controlled operation is selected for more small scaled applications which prevents total black out I M S IntenZ Matrix System The IntenZ CB 150 is equipped with the special IntenZ Matrix System which makes it possible to mount several fixtures in a matrix setup Vertical coupling of the fixtures is possible to make large setups with 5 CB 150 fixtures 25 pixels in a row Horizontal coupling when the fixture is in vertical position is also possible which creates a 5x5 matrix panel made from 5 CB 150 fixtures NOTE Always attach the included safety pins If lost contact your local dealer for replacements Vertical array vertical fixtures To make a vertical array of several IntenZ CB 150 fixtures in vertical mode use the included hardware The large couplers are needed for a vertical array A max
12. rophone which senses the beat of the music and will change a step every time a beat is detected Slave In master slave mode it is possible to link several IntenZ CB 150 fixtures together to create synchronized lightshows in the Auto or Sound mode The first fixture in the chain needs to be set in the Auto or Music mode All the next fixtures need to be set to Slave and will mimic the behavior of the first fixture The master slave function requires XLR XLR cables not included DMX The Intenz CB 150 can be connected to a DMX controller with standard XLR XLR cable While doing so a DMX terminator must be connected to the last fixture at the end of the DMX chain This prevents reflections in the DMx signal which could cause flickering and unwanted behavior from your intelligent fixtures A DMX terminator is a XLR connector with a resistor of 120 Ohm placed between pin 2 and 3 as a bridge With the following channel assignment it is possible to control the IntenZ CB 150 1CH mode 000 007 Blackout 008 022 Show 1 023 037 Show 2 038 052 Show 3 053 067 Show 4 068 082 Show 5 083 097 Show 6 098 112 Show 7 113 127 Show 8 128 142 Show 9 143 157 Show 10 158 172 Show 11 173 187 Show 12 188 202 Show 13 203 217 Show 14 218 232 Show 15 233 247 Show 16 248 255 Sound active running show 1 to 16 3CH mode 000 255 Red ooo OO 000 255 000 255 5CH Mode 000 255 The 1 head Color 000 255 The 2 head Color 000 255
13. uddenly loses DMX signal By activating the function the fixture goes in blackout mode By deactivation the mode the fixture goes in sound controlled mode Led The LED display will shut off automatically after a few seconds when this function is activated When pressing any button the display will activate again When deactivating the feature the display will be lit permanently DISP Display invert version When using the fixture in a hanging setup it is possible to flip the display so the characters will be shown upside down This makes reading the several statuses much easier TEST Self test mode to control all segments and LEDs TEMP Current temperature displayed in degrees Celsius Hour The fixture shows how much hours it has been active This is very practical for rental companies which need to perform service intervals on all fixtures after several hours of performing to maintain optimal shape The IntenZ CB 150 is equipped with several working modes each with its own advantages For simple events there are stand alone modes for advanced situations there are options to create synchronized lightshows and the fixture is able to be controlled with a DMX 512 controller A short description for each mode can be found below Auto Automatic lightshow with a pre programmed internal show on a pre defined speed Sound Automatic lightshow with a pre programmed internal show on the beat of the music thanks to an internal mic
14. use other types of cables than specified in the manual do not use defective or bad functioning cables Contact your dealer when the included or required cables do not work properly with this device When the device has been exposed to large temperature differences for example transport from outdoor to indoor do not connect the device immediately Do not activate the unit until it has reached room temperature as moist might build up inside the unit which may cause shortcuts and or electrical shocks Guidelines and types of use This device is intented to be used by professionals on stage in theatres clubs and other equal venues This device is not suitable for children and always needs to be operated by an adult Only use the device when the environment is suitable and will not cause any damage Do not use the product in moist or dusty environments or where long term damage may occur such as indoor swimming pools where chlorine is used Beaches where sand and salt are present Outdoor without roof protection Indoor areas where intense heat sources are present or where the temperature exceeds levels which are comfortable for humans Only use the included power adapter and only connect the device to a suitable power outlet with the correct output voltage Connecting the device to a power outlet with the wrong type of voltage or using the prodcut with a wrong type of power supply may cause permanent damage to the device A
15. void shocks and collission during use and transport Do not transport the device while in use Avoid brute force during the installation and operation of this device Familiarise yourself with the functions of the device before use Do not allow operation of the device by unskilled or unqualified people Use of the device in other ways than described in this user manual may cause damage and injury Ayra does not take responsibility for any damage or injury caused by improper use Storage and transport This device is intended for mobile use When transported use the original packaging of the product or a fitting flightcase preferably filled with foam This device is not intended for permanent use Operation breaks will ensure that the lifespan of the device remains unchanged If the device is not used for a longer period of time disconnect it from its power source and store it in its original packaging or in a fitting flightcase Store the device indoor dry and do not expose the device to extreme temperature differences Housing Inspect the housing of the device frequently Severe dents cracks and missing screws should be avoided at all costs Do not use the device when the housing is not in optimal condition Contact your dealer or a skilled technician when in doubt about the state of the device Check the fixture and screws for corrosion Corrosion should not be present on the fixture Contact your dealer or a skilled tec