Home

PLPROFILE1 MKII LED Luminaire - User`s

image

Contents

1. Figure 4 PLPROFILE1 MKII LED Luminaires DMX512 Connections INSTALLATION AND SET UP PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual PHILIPS Selecon Mounting WARNING Before attempting any installation or service disconnect all power at power source Dimming the luminaire does not disconnect power Installation and service should only be performed by a trained and qualified professional Using Supplied C Clamp As illustrated in Figure 5 at yoke assembly thread clamp mounting bolt with washer installed through center clamp mounting hole at top of yoke through Top Box Assembly and thread bolt into C Clamp Securely tighten bolt by hand into clamp but do not over tighten Note Top box will be able to swivel once bolt is tightened by design DO NOT OVER TIGHTEN C Clamp Top Box Assembly Flat Washer Center Clamp Mounting Hole 13 mm Flat Washer WARNING When installing a C Clamp or hook or other type of clamp with the Top Box Assembly C Clamp Bolt as shown you MUST use C Clamp Bolt supplied with the fixture Failure to do so may result in damage to the Top Box Assembly or cause the luminaire to dislodge from the clamping device Yoke Assembly Top Box Assembly NOTE To allow for proper cooling make sure luminaire head is orientated as shown with cooling vents pointe
2. sees eene nennen nennen nennen en nennen 6 6 INSTALLATION AND SET UP Power Requirements Eee reso eto e ee EH e ti en ir des CE dabei 7 Connecting POWet o te EH RE re Ee e HERR C e 7 Connecting to the DMX512 8 MONNE A LE DUE D EN 9 Using Supplied C C lamp eei et E UAE MANI AREE ENTE as 9 Safety Cable Ue a dier diiit pete inet 10 and Tilt Adjustments uie ot REA LOIRE RE Ere ER ee 10 10 Tilt Adjustmerit incite 10 FOCUS AND BEAM ADJUSTMENTS Lens Tray Removal and Installation rte eerte eae a neti EHE eatin E HEN Nene 11 Zoom and Focus Adjustments cccceccesceeceseeecececseecseeseeceecsaeeseseeceseseeceseseeeeeecseecaeesaecaecaeeaeeaeeeseeeeeeseeseerseeeens 11 Beam Shutter Operation ccccccecccescessessesseescecsecseceaecseceseeeessssseseseeseseeecaessaecaassaecaecsaeeaeeseseseseseaeseaseseseecaeeeaeeaes 12 P 13 OPERATIO
3. 106 26 42 107 27 108 28 109 29 43 110 30 111 31 44 112 32 113 33 114 34 45 115 35 PHILIPS as PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail 27 Selecon Installation amp User s Manual PLPROFILE1 MKII LED Luminaires 28 DMX CONTROL Value DMX Seconds 116 36 46 117 37 118 38 119 39 47 120 40 121 41 48 122 42 123 43 124 44 49 125 45 126 46 127 47 50 128 48 129 49 51 130 50 131 51 132 52 52 133 53 134 54 53 135 55 136 56 137 57 54 138 58 139 59 55 140 60 141 61 142 62 56 143 63 144 64 57 145 65 146 66 147 67 58 148 68 149 69 59 150 70 151 71 152 72 60 153 73 154 74 155 75 61 156 76 157 77 62 158 78 159 79 160 80 63 161 81 162 82 64 163 83 164 84 165 85 65 166 86 167 87 66 168 88 169 89 PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Value DMX Seconds 170 90 67 171 91 172 92 68 173 93 174 94 175 95 69 176 96 177 97 178 98 70 179 99 180 100 71 181 101 182 102 183 103 72 184 104 185 105 73 186 106 187 107 188 108 74 189 109 190 110 75 191 111 192 112 193 113 76 194 114 195 115 77 196 116 197 117 198 118 78 199 119 200 120 79 201 121 202 122 203 123 80 204 124 205 125 81 206 126 207 127 208 128
4. 82 209 129 210 130 211 131 83 212 132 213 133 84 214 134 215 135 216 136 85 217 137 218 138 86 219 139 220 140 221 141 87 222 142 223 143 PHILIPS PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail 29 Selecon Installation amp User s Manual PLPROFILE1 MKII LED Luminaires 30 Value DMX Seconds 88 224 144 225 145 226 146 89 227 147 228 148 229 149 90 230 150 231 151 91 232 152 233 153 234 154 92 235 155 236 156 93 237 157 238 158 239 159 94 240 160 241 161 95 242 162 243 163 244 164 96 245 165 246 166 97 247 167 248 168 249 169 98 250 60mS 251 80mS 99 252 100mS 253 120mS 254 140mS 100 160mS Note DMX values 250 to 255 provide smoothing when using console fade timing DMX value 255 recommended default will provide the smoothest timing DMX CONTROL PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual 5 PLPROFILE1 MKII LED Luminaire RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with PLPROFILEI LED Luminaires Table 4 PLPROFILEI LED Luminaire RDM Product Parameters IDs Table 5 PLPROFILEI MKII LED Luminaire RDM UID Table 6 PLPROFILEI LED Luminaire RDM Parameters IDs Table 7 PLPROFILEI MKII LED Luminaire RDM Manufacturer Status IDs on page 33 Table 4 PLPROFILE1 MK
5. DMX 58 59 Preset 21 Store DMX 60 61 Preset 22 Store DMX 62 63 Preset 23 Store DMX 64 65 Preset 24 Store DMX 66 67 Preset 25 Store DMX 68 69 Preset 26 Store DMX 70 71 Preset 27 Store DMX 72 73 Preset 28 Store DMX 74 75 Preset 29 Store DMX 76 77 Preset 30 Store DMX 78 79 Preset 31 Store DMX 80 81 Preset 32 Store DMX 82 83 Color Normalization ON DMX 100 103 Color Normalization OFF DMX 104 107 Fixture Reset DMX 108 112 Red Correction ON DMX 113 115 Red Correction OFF DMX 116 118 NOTE Denotes default settings and return to default when performing control channel values 5 7 22 DMX CONTROL PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual 2 8 Bit Mode Table 2 1 provides DMX channel mapping of all DMX512 control values when the PLPROFILEI MKII LED Luminaire is in 8 bit DMX512 mode as set by the luminaire s menu system Table 2 1 PLPROFILE1 MKII LED Luminaire DMX Channel Mapping 8 Bit Mode Default DMX recommended Channel Parameter Range DMX Range console default values Description Intensity 0 255 0 100 0 8 bit control for Intensity of LED settings Red 0 255 0 100 8 bit control of Red LEDs from 0 to full Green 0 255 0 100 8 bit control of Green LEDs from 0 to full Blue 0 255 0 100 8 bit control of Blue LEDs from 0 to full White 0 255 0 100 8 bit control of White
6. Power Requirements 7 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Table 1 PLPROFILEI LED Luminaire AC Input Connections Wire Color Purpose Brown Main Line 100 to 240VAC Blue Neutral Green Yellow Ground Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple PLPROFILE1 LED Luminaires together up to 30 luminaires in daisy chain fashion A cable runs from the control console or DMX512 control source to the DMX connector on the first PLPROFILEI MKII LED Luminaire Another cable runs from the other DMX connector on the first unit to a DMX connector the next PLPROFILEI LED Luminaire or DMX512 device to be controlled Neutral AC Input Connector on back of unit Ground Earth Main Line Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For PLPROFILEI MKII LED Luminaire DMX Mapping refer to DMX CONTROL on page 21 PLPROFILE1 MKII LED Luminaires DMXS512 out from first to second luminaire DMXS12 out to the next luminaire or DMX512 controlled device DMX512 from console or control device d DMX512 Connections Data Thru Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Data In Cable Pinout Cable Pinout Common Data Data Not Used Not Used Drain 1 5 2 4 3 Male Conn Female Conn
7. use the UP ARROW or DOWN ARROW keys to move the highlight to the settings value you wish to change Press OK to begin editing that value Use the UP ARROW DOWN ARROW LEFT ARROW or RIGHT ARROW keys to make changes to the value Press OK when complete to save changes or ESC to cancel changes to that value When done making changes on the Settings Screen press ESC to re boot fixture and implement changes Fixture will not re boot if nothing was changed PHILIPS Sel econ Presets 19 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Table 2 Settings Menu User Settable Parameters Parameter Values Default Description General Normal Mode 120W Sets the luminaire s output mode Normal Power Fan Studio Mode 80W or Normal Mode Mode 120W Studio Mode 80W or Quiet Mode 60W Quiet Mode 60W Users can set what the default preset is Power Up All presets Cool White when the unit is powered up Factory default is Cool White Red Correct No Yes No Turns on or off red correction Reset Hours No Yes No Resets luminaire s operational hours Set PIN Hb 0000 four zeros A four digit user settable PIN code to lock the fixture Presets Determines if the factory Presets Color Protected No 5 25 5 25 Mix is protected from changes Load Factory No Yes No Reload Factory Presets Intensity changes will also be reloaded DMX DMX512 address
8. 5 Chan Mode Default values 1 Intensity 0 255 0 100 0 8 bit control for Intensity of LED settings 2 Red 0 255 0 10096 0 8 bit control Red LEDs 3 Green 0 255 0 100 0 8 bit control Green LEDs 4 Blue 0 255 0 100 0 8 bit control Blue LEDs 5 White 0 255 0 100 0 8 bit control White LEDs 4 PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail Timing channel control improves the timed moves of certain groups of parameters The PLPROFILEI MKII LED Luminaire provides two timing channels in 16 bit mode one for intensity time and one for color time and one timing channel in 8 bit color and intensity timing combined The luminaire uses its timing channel value to calculate a smooth continuous operation for a given time and transition Guidelines Timing channels support time values from zero to 169 seconds Tousea timing channel instead of console timing it is recommended to set the timing channel to the desired value and set cue and or console cue fade time to zero A combination of time controls can produce unexpected results The default value setting in the profile should be 255 proportional control to allow smooth operation when using console timing The timing channel data should change as a snap A zero value will give the fastest operation however without any smoothing this can appear steppy in console timed moves Table 3 PLPROFILE1 MKII LED Luminaire Timin
9. LEDs from 0 to full Used to access presets stored in fixture firmware such as CCT presets defined gel presets etc oa ft w nN ojoj o o No Preset Activated DMX 0 3 default Color Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Color Preset 3 Cool White DMX 16 19 Color Preset 4 Daylight DMX 20 23 Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Color Preset 8 Daylight Blue DMX 36 39 Color Preset 9 Magenta DMX 40 43 Color Preset 10 Aqua DMX 44 47 Color Preset 11 Medium Amber DMX 48 51 Color Preset 12 Lavender DMX 52 55 Color Preset 13 Blue DMX 56 59 Color Preset 14 Light Pink DMX 60 63 Color Preset 15 Green DMX 64 67 Color Preset 16 Pink DMX 68 71 Color Preset 17 Amber White DMX 72 75 Color Preset 18 Dark Fuchsia DMX 76 79 Color Preset 19 Light Amber DMX 80 83 Color Preset 20 Steel Blue DMX 84 87 Color Preset 21 Lt Green Blue DMX 88 91 Color Preset 22 Orange DMX 92 95 Color Preset 23 Medium Pink DMX 96 99 Color Preset 24 Cyan DMX 100 103 Color Preset 25 Purple DMX 104 107 Color Preset 26 Custom DMX 108 111 Color Preset 27 Custom DMX 112 115 Color Preset 28 Custom DMX 116 119 Color Preset 29 Custom DMX 120 123 Color Preset 30 Custom D
10. Note it can be set if Address 001 to 512 001 displayed Defines size precision of DMX map Color Map 8 bit 16 bit or 5 Chan 16 bit Mixing Intensity in 16 bit provides higher resolution for precision control 5 Chan provides minimal channel usage If DMX is detected and then goes away Off Hold Hold 8Hr 8 this defines what will happen to the output When po DMX hours or No Output At end of 8Hr hold Fixture goes to No Output setting Display Flip Display No Yes No Flips inverts Display and Keypad Arrows Use left or right arrow keys to adjust 9 0 Adj Contrast 0 100 209 display contrast as desired Fixture Fixture ID Shows Fixture Type Profile Cyc or Fresnel Shows luminaire type Note To Exit the Settings screen use the ESC key ESC and OK can be used to cancel or save changes to an individual parameter However once a parameter has been accepted by pressing OK that change cannot be undone canceled by pressing the ESC key PHILIPS Selecon 20 OPERATION AND PROGRAMMING PLPROFILE1 MKII LED Luminaires Installation amp User s Manual DMX CONTROL This section contains information for operating the luminaire using DMX control in 16 Bit 8 Bit or 3 Channel 3 Chan modes For Menu options and detailed information see Settings on page 19 Note These tables assume a DMX start address of 1 When a different starting address is used this address becomes channe
11. User s Manual PLPROFILE1 MKII LED Luminaires TROUBLESHOOTING 36 1 AN Troubleshooting Guide The chart below provides possible causes and remedies for various error messages and or symptoms WARNING Any service and maintenance including troubleshooting other than described herein should be performed by an Authorized Philips Selecon Dealer or Service Center Description Symptom Possible Cause Remedy No light output Fixture will not produce or output light Unit is set to Preset Off Make sure unit is set to proper Preset DMX command to 0 intensity Adjust intensity to higher level No power at luminaire DMX Data Control Luminaire does not power up Fixture will not respond to DMX commands Circuit not energized verify circuit breaker is turned on Not plugged in ensure A C cable is connected to power source Power cable wired incorrectly verify power cable and connector are wired correctly See Connecting Power on page 7 for more information Not detecting DMX data Disconnect and reconnect DMX input cable Unit is not set to be controlled by DMX check menu settings Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See Connecting to the DMX512 Network on page 8 for more information LED light is getting dimmer Fix
12. changed Three Presets 5 through 25 are Locked Preset 0 the off preset is also Locked to the OFF value fthe fixture is unlocked User Presets can have their Color Mix and Intensity changed without restriction Note Ifthe Color Mix of a Factory Calibrated Preset is changed by turning protection Off an is appended to the end of the Preset s Name to indicate that the Calibrated values have been changed Note DMX will take priority over any menu selected preset Editing Preset Names On the Edit Preset screen the option is available to edit the name of a preset via Screen button However the names of Presets 0 2 3 and 4 cannot be edited Scratch Pad preset 1 can be changed but retains its original functionality Use the LEFT ARROW and RIGHT ARROW keys to select the character to be changed and use the UP ARROW and DOWN ARROW keys to change that character The Character Scroll order is A Z space 0 9 If you are scrolling up the Alpha character displays as Upper Case if you are scrolling down the Alpha character displays as Lower Case Stop on the character you want ignoring case then press the opposite UP ARROW or DOWN ARROW key if you want to change the case OK to save changes ESC to cancel changes 6 Settings Table 2 Settings Menu User Settable Parameters on page 20 shows the user settable parameters available in the Settings menu section To edit a value on the Setting Screen
13. depending on which arrow button is pressed status screens may appear in reverse order a DMX Address note if fixture is UNLOCKED hit OK to change DMX address b Fixture Hours displays fixture operating hours since last reset c Fixture Power displays Max Power Limit setting in Watts Present Power consumed by fixture in Watts and Hours of Use d Fixture Status displays current operational temperature LED status and fan speed setting Step 2 Press LEFT or RIGHT arrow buttons to scroll through status screens Step 3 Press ESC at anytime to access Main Menu PHILIPS Selecon LCD Menu System 15 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires 3 Menu Structure Note See To navigate and access menu settings selections on page 15 to learn how to access menus To save changes hit OK Press ESC to cancel any changes you made LCD Display Menu System MAIN MENU Save a Preset Sub Menu Options Comments Users Save the current settings look to a specific recallable Preset in the Select Preset to Save Option Scratch Pad fixture s memory Edit the levels values for Red Scrolls and sets current user defined Warm White Green Blue White and Intensity color mix to various recallable presets values in percent by using the in
14. 6 PLPROFILE1 MKII LED Luminaire RDM Parameters IDs mom nam RDM Parameter IDs Value Comment Implemented MANUFACTURER LABEL 0x0081 n H m DEVICE LABEL 0x0082 H H H FACTORY_DEFAULTS 0x0090 LANGUAGE CAPABILITIES 0 00 0 LANGUAGE 0 00 0 H SOFTWARE_VERSION_LABEL 0 00 0 H H BOOT_SOFTWARE_VERSION_ID 0x00C1 BOOT SOFTWARE VERSION LABEL 0x00C2 Category DMX512 Setup H H DMX_PERSONALITY 0 00 0 H PERSONALITY DESCRIPTION 0 00 1 n DMX START ADDRESS 0 00 0 2 device uses SLOT INFO 0x0120 H n SLOT DESCRIPTION 0x0121 B DEFAULT SLOT VALUE 0x0122 Category Sensors 0x02xx SENSOR DEFINITION 0x0200 n H SENSOR VALUE 0x0201 Bl RECORD SENSORS 0x0202 Category Dimmer Settings 0x03xx FUTURE USE Category Power Lamp Settings 0x04xx m DEVICE HOURS 0x0400 LAMP HOURS 0x0401 n H LAMP_STRIKES 0x0402 n LAMP STATE 0x0403 El LAMP ON MODE 0x0404 DEVICE POWER CYCLES 0x0405 Category Display Settings 0x05xx DISPLAY INVERT 0x0500 H DISPLAY_LEVEL 0x0501 Category Configuration 0x06xx gm PAN INVERT 0x0600 INVERT 0x0601 PAN TILT SWAP 0x0602 m H REAL_TIME_CLOCK 0x0603 Category Control 0x10xx H H IDENTIFY_DEVICE 0x1000 H H RESET_DEVICE 0x1001 H POWER STATE 0x1010 H PERFORM_SELF
15. AC input cable or accessories Compliance cETLus Listed CE and C Tick Marked Note Common model specifications shown For specific model specifications features and accessories refer to the product specification sheet or visit the Philips Selecon web site at www seleconlight com for more details 2 PLPROFILE1 MKII LED Luminaire Dimensions 310 0 mm 12 2 in 664 9 mm 26 2 in 173 0 mm 6 8 in T T E O 8 all Intertek PHILIPS Selecon PLPROFILE1 MKII LED Luminaire Operational Specifications 37 PHILIPS Selecon Philips Selecon Dallas 10911 Petal Street Dallas TX 75238 Tel 1 214 647 7880 Fax 1 214 647 8031 Philips Selecon Hong Kong Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Philips Selecon Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Philips Selecon Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel 31 0 543 542516 www seleconlight com
16. II LED Luminaire RDM Product Parameters IDs Model ID Model Description Product Category 0X008C Philips Selecon PL ZoomSpot MK2 0X0101 Table 5 PLPROFILE1 MKII LED Luminaire RDM UID MSB of ESTA LSB of ESTA 1st of 2nd of 3rd of 4th of 50H 41H Unique Seq Unique Seq Unique Seq Unique Seq Table 6 PLPROFILE1 MKII LED Luminaire RDM Parameters IDs Get Set Allowed Allowed RDM Parameter IDs Value Comment Implemented Category Network Management DISC UNIQUE BRANCH 0x0001 DISC MUTE 0x0002 DISC UN MUTE 0x0003 PROXIED_DEVICES 0x0010 DEVICES COUNT 0x0011 5 STATUS 0 0015 Category Status Collection QUEUED MESSAGE 0x0020 STATUS MESSAGES 0x0030 STATUS ID DESCRIPTION 0x0031 CLEAR STATUS ID 0x0032 H SUB_DEVICE_STATUS_REPORT_THRESHOLD 0x0033 Category RDM Information Support required only if supporting Parameters SUPPORTED PARAMETERS 0x0050 beyond the minimum required set Support required for Manufacturer Specific PIDs n PARAMETER DESCRIPTION 0x0051 exposed in SUPPORTED PARAMETERS message Category Product Information DEVICE INFO 0x0060 m PRODUCT DETAIL ID LIST 0x0070 n DEVICE MODEL DESCRIPTION 0x0080 PHILIPS PLPROFILE1 MKII LED Luminaire RDM Parameter IDs 31 Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Table
17. MX 124 127 Color Preset 31 Custom DMX 128 131 No Preset Activated DMX 253 255 6 Preset Color Selection 0 255 0 100 0 7 Not used for future use Allows for timing control of both the intensity and color parameters Channel should default to 255 for smoothest actions using console and or 0 3 Timing 15258 299 manual fades Refer to PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail on page 25 for more information PHILIPS Selecon 8 Bit Mode 23 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Table 2 1 PLPROFILE1 MKII LED Luminaire DMX Channel Mapping 8 Bit Mode Control 0 255 0 100 Used to set different modes parameters and functions of the luminaire Set control channel value for desired action Hold value for at least 3 seconds Set control channel value to 0 without any scaling Default Setting on Console DMX 0 Display On Off DMX 3 4 Reset All Settings to Defaults DMX 5 7 Quiet Mode DMX 8 10 Studio Mode DMX 11 13 Normal Mode DMX 14 15 Preset 1 Store DMX 20 21 Preset 2 Store Intensity Only DMX 22 23 Preset Store Intensity Only DMX 24 25 Preset 4 Store Intensity Only DMX 26 27 Preset 5 Store DMX 28 29 Preset Store DMX 30 31 Preset 7 Store DMX 32 33 Preset 8 Store DMX 34 35 Preset 9 Store DMX 36 37 Preset 10 Store DMX 38 39 Preset 11 Sto
18. Manual L ers a UJ e t tallation ins Selecon PLPROFILE1 MKII LED Luminaires For 251 1834 03 amp PLZSIMKII 2444 03 Philips Selecon Offices Philips Selecon Dallas 10911 Petal Street Dallas TX 75238 Tel 1 214 647 7880 Fax 1 214 647 8030 Philips Selecon Asia Limited Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Philips Selecon Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Philips Selecon Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel 852 2796 9786 Tel 31 0 543 542516 Fax 852 2798 6545 Website www seleconlight com The material in this manual is for information purposes only and is subject to change without notice Philips Selecon assumes no responsibility for any errors or omissions which may appear in this manual For comments and suggestions regarding corrections and or updates to this manual please visit the Philips Selecon web site at www seleconlight com or contact your nearest Philips Selecon office El contenido de este manual es solamente para informaci n y est sujeto a cambios sin previo aviso Philips Selecon no asume responsabilidad por errores o omisiones que puedan aparecer Cualquier comentario sugerencia o correcci n con respecto a este manual favor de dirijirlo a la oficina de Philips Selecon
19. N AND PROGRAMMING LED Men Operationen secie iiaii e Fee 14 LCD Syste te dioere Heer 15 lupe 16 Nes 18 ETT 18 19 Editing Preset Names 19 NODUIPIPRMC m 19 PHILIPS 2 Maca aaO Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual DMX CONTROL E Mod un tarum tro meruerat oed ee teritur ALTE n eee ate a ee PUE 21 8 Bit EM 23 DMX 5 Channel 5 Chan Mode essit nennen rne nn enne 25 PLPROFILEI LED Luminaire DMX Timing Channel Detail sese 25 PLPROFILEI LED Luminaire RDM Parameter 5 31 CLEANING AND CARE Special Cleaning and Care Instr ctiorns 34 Lens Tray Assembly Cleaning secin ne e anean nE E Era rE EE EE SaR E ERE TEN 34 Service and Maintenance eiie a a ere EU AA E E EL E P EHE 35 550 8 pee E E A 35 TROUBLESHOOTING Troubleshooting Guide etie iet teils voe dso 36 TECHNICAL SPECIFICATIONS PLPROFILEI LED Luminaire Operational Specifications eese 37 PLPROFILEI LED Luminaire Dimensions sessssseeee
20. TEST 0x1020 SELF TEST DESCRIPTION 0x1021 CAPTURE PRESET 0x1030 PHILIPS 32 DMX CONTROL Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Table 6 PLPROFILE1 MKII LED Luminaire RDM Parameters IDs Get Set Table 7 PLPROFILE1 MKII LED Luminaire RDM Manufacturer Status IDs Manufacturer Specific messages are in the range of 0x8000 OXFFDF Each Manufacturer specific Status ID shall have a unique meaning which shall be consistent across all products having a given Manufacturer ID See Table B 2 ANSI E1 20 2010 Status ID Message Value Data Value 1 Data Value 2 Status ID Description 8100H 00H 00H ALL OK PHILIPS Selecon PLPROFILE1 MKII LED Luminaire RDM Parameter IDs 33 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires CLEANING AND CARE 34 WARNING cleaning should be performed with power completely removed from luminaire Never remove protective covers when luminaire is powered Wear appropriate protective eye wear and gloves when cleaning the fixture All service and maintenance other than described herein should be performed by a qualified technician or Authorized Service Center Special Cleaning and Care Instructions Being a solid state fixture and unlike most fixtures the PLPROFILEI MKII LED Luminaire requires very little routine maintenance by the user This section covers portions of the luminaire that can be remo
21. anual PLPROFILE1 MKII LED LUMINAIRE OVERVIEW 1 PLPROFILE1 MKII LED Luminaire Components Major Luminaire Components Top Box Assembly PLICB AC Input Thru and DMX In Out Connections Accessory Holder with latching door Yoke Locking Handle Front of Unit Beam Shutter 4 each Beam Angle Adjustment Beam Focus Adjustment Lens Tube Assembly Multi Conductor Fixture Connection Safety Cable Anchor Point LCD Display Menu System Rear of Unit For the LCD Display Menu System refer to LCD Display Menu System on page 6 for more information Figure 1 PLPROFILE1 MKII LED Luminaire Components PHILIPS PLPROFILE1 MKII LED Luminaire Components 5 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Top Box PLICB Luminaire Connections DMX512 Input Multi Conductor Top Box to Luminaire Connection DMX512 Output Thru Side View 1 AC Power Input Multi Conductor Top Box to Luminaire Connection Side View 2 AC Power Output Figure 2 Top Box PLICB Connections LCD Display Menu System PHILIPS Selecon O INTENSITY MENU 1 LCD Display Menu System 2 Preset Intensity Menu Access Buttons 3 Function Menu System Select Push Buttons Note For Menu operation and programming details re
22. d upwards Figure 5 Luminaire Mounting To mount on a telescopic stand reverse the yoke under the luminaire and bolt to stand Please note luminaire orientation see note in Figure 5 for proper cooling Note After installing Clamp and Top Box assembly connect luminaire cable assembly to Top Box Assembly before mounting luminaire Please note that the cable connector is keyed Mounting 9 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Safety Cable Use The supplied safety cable MUST always be used when rigging luminaires on bars truss etc as shown in Figure 6 The supplied safety cable is recommended for all hanging installation and may be required by national and local codes Loop or attach safety cable to luminaire safety cable anchor point as shown and attach to structure You should always consult and follow all local and national codes and regulations for mounting and installation of luminaire Pan and Tilt Adjustments Pan Adjustment The pan adjustment of a PLPROFILEI LED Luminaire is achieved by loosening the yoke bolt of the securing clamp attached to the luminaire s yoke assembly Loosen the bolt set the luminaire to the desired position and re tighten Tilt Adjustment PLPROFILEI LED Luminaires offer variable tilt settings The unit can be set at a specific angle in relation to its mounting position or at an angle between 0 to 90 degrees When the yoke is in the pos
23. e to the lens tray on a PLPROFILEI MKII LED Luminaire Zoomspot lens trays as shown in PLPROFILE1 LED Luminaire Zoomspot Lenses on page 4 are interchangeable To remove and install lens tubes Step 1 Before proceeding it is recommended to move the zoom and focus lenses towards the center of the lens tray assembly away from the front and back edges Step 2 Unlatch lens tray as illustrated Figure 7 Be careful as the lens tray assembly will swing open if not properly supported PLPROFILE1 MKII LED Luminaire Lens Tray Assembly Lens Tray Latch Figure 7 Lens Tray Assembly Removal Step 3 With lens tray assembly open hanging down lift lens tray assembly up and out of its hinged position to free it from luminaire Step 4 To install perform process in reverse CAUTION Ensure the lens tray assembly locking catch is fully engaged before putting fixture into use 2 Zoom and Focus Adjustments To adjust zoom beam angle and focus Step 1 Make sure all frame shutters are open out of beam path See Beam Shutter Operation on page 12 for more information Step 2 Asshown in Figure 8 loosen Zoom Adjustment Knob and set beam angle as desired Step 3 Hand tighten Zoom Adjustment Knob to lock position Step 4 Loosen Focus Adjustment Knob Step 5 Move Focus Adjustment Knob along forward or back until beam focus is set as desired PHILIPS Selecon Lens Tray Removal and Installation 11 Installatio
24. een 37 PHILIPS Es Selecon 3 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires PREFACE 1 About this Manual The document provides installation and operation instructions for the following products LED Luminaire 18 34 Degree Zoomspot PLZS1MKII 1834 03 LED Luminaire 24 44 Degree Zoomspot PLZSIMKII 2444 03 Please read all instructions before installing or using this product Retain this manual for future reference Additional product information and descriptions may be downloaded at www seleconlight com Note PLPROFILEI LED Luminaires are universal voltage 100VAC to 240VAC Auto ranging 2 Accessories Contact your Authorized Philips Selecon Dealer for price and availability of all accessories for PLPROFILE1 LED Luminaires Additional information can be found on the Philips Selecon web site at www seleconlight com PLPROFILE1 MKII LED Luminaire Power Input Cables Part Number Description PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon without PC1BE Connector user to supply AC connector PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with PC1GP Stagepin Connector PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with PC1GTL i Twistlock Connector PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 mete
25. es our guarantee against premature failure of the LED engine PHILIPS Selecon Installation amp User s Manual PLPROFILE1 MKII LED Luminaires TABLE OF CONTENTS Philips Selecon Offices irr cst tied derit Inside Front Cover IMPORTANT INFORMATION Warnings and NOt IC 1 Additional Resources for DMX S 12 1 Philips Selecon Limited Three Year Warranty 1 TABLE OF CONTENTS PREFACE About this Manual scccnciiissceesants 4 ACCESSO S orto d ene LM ELLE DAI eter eer te cere tay E 4 PLPROFILE1 LED Luminaire Power Input 1 4 PLPROFILEI LED Luminaire Zoomspot Lenses 4 4 PLPROFILE1 MKII LED Luminaire Imaging Accessories 4 PLPROFILEI LED Luminaire Clamps 4 PLPROFILEI LED Luminaire USB Luminaire Software Cable 2 4 PLPROFILEI LED Luminaire Top Box Assembly esee 4 PLPROFILE1 MKII LED Luminaire OVERVIEW PLPROFILEI LED Luminaire 5 Major Luminaire 5 Top Box PLICB Luminaire Connections
26. fer to LCD Menu Operation on page 14 Figure 3 PLPROFILE1 MKII LED Luminaire LCD Display amp Menu System PHILIPS Selecon PLPROFILE1 MKII LED Luminaire OVERVIEW PLPROFILE1 MKII LED Luminaires Installation amp User s Manual INSTALLATION AND SET UP 1 Power Requirements WARNING The PLPROFILEI LED Luminaire should be connected to a constant circuit or a relay device It should never be connected to a dimmer or circuit controlled by a dimmer PLPROFILE1 LED Luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Depending on supply voltage each luminaire can draw up to 140 Watts The maximum through current should not exceed 20 Amps WARNING The Maximum Allowable Input Current of 20 Amps and the maximum power supply limit of 140 Watts Do not overload circuits Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector Doit tre aliment par un circuit de d rivation prot g par un maximum de 20 amperes circuit protecteur Do not overload circuits IMPORTANT AC POWER CONNECTION NOTES PHILIPS Selecon 100 240 50 60 Hz AC Only PHILIPS q 0 3m V 140 Watts Max 3 1 2A 115VAC 0 6 2 Selecon 7899 Intertek 20A Max Thru Current PLZS1MKII 1834 03 AUS Conforms to UL1573 PLZS1MKII 2444 03 Not for Residential use Dr
27. g Channel Detail Value DMX Seconds 0 0 Full Speed 1 0 2 2 0 4 1 3 0 6 4 0 8 2 5 1 6 1 2 7 14 3 8 1 6 9 1 8 4 10 2 11 22 PHILIPS Selecon DMX 5 Channel 5 Chan Mode 25 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires 26 DMX CONTROL Value DMX Seconds 12 24 5 13 2 6 14 2 8 6 15 3 16 32 17 34 7 18 3 6 19 3 8 8 20 4 21 4 2 22 44 9 23 4 6 24 4 8 10 25 5 26 5 2 27 54 11 28 5 6 29 5 8 30 6 12 31 6 2 32 6 4 13 33 6 6 34 6 8 35 7 0 14 36 72 37 74 15 38 7 6 39 7 8 40 8 16 41 82 42 84 17 43 8 6 44 8 8 45 9 18 46 9 2 47 9 4 19 48 9 6 49 9 8 50 10 20 51 10 2 52 10 4 53 10 6 21 54 10 8 55 11 22 56 11 2 57 11 4 58 11 6 23 59 11 8 60 12 24 61 12 2 PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Value DMX Seconds 62 124 63 12 6 25 64 12 8 65 13 26 66 13 2 67 134 68 13 6 27 69 13 8 70 14 28 71 14 2 72 144 73 14 6 29 74 14 8 75 15 30 76 15 2 77 154 78 15 6 31 79 15 8 80 16 81 16 2 32 82 16 4 83 16 6 33 84 16 8 85 17 86 17 2 34 87 174 88 17 6 35 89 17 8 90 18 91 18 2 36 92 18 4 93 18 6 37 94 18 8 95 19 96 19 2 38 97 19 4 98 19 6 39 99 19 8 100 20 101 21 40 102 22 103 23 104 24 41 105 25
28. imes Refer to PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail on page 25 for more information on timing values 14 Color Time 0 255 0 100 255 Allows for luminaire timing of LEDs Profile should default to DMX 255 for smoothest console fade times Refer to PLPROFILE1 MKII LED Luminaire DMX Timing Channel Detail on page 25 for more information on timing values 15 Control 0 255 0 100 Used to set different modes parameters and functions of the luminaire Set control channel value for desired action Hold value for at least 3 seconds Set control channel value to 0 without any scaling Default Setting on Console DMX 0 Display On Off DMX 3 4 Reset All Settings to Defaults DMX 5 7 Quiet Mode DMX 8 10 Studio Mode DMX 11 13 Normal Mode DMX 14 15 Preset 1 Store DMX 20 21 Preset 2 Store Intensity Only DMX 22 23 Preset 3 Store Intensity Only DMX 24 25 Preset 4 Store Intensity Only DMX 26 27 Preset 5 Store DMX 28 29 Preset 6 Store DMX 30 31 Preset 7 Store DMX 32 33 Preset 8 Store DMX 34 35 Preset 9 Store DMX 36 37 Preset 10 Store DMX 38 39 Preset 11 Store DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 Preset 15 Store DMX 48 49 Preset 16 Store DMX 50 51 Preset 17 Store DMX 52 53 Preset 18 Store DMX 54 55 Preset 19 Store DMX 56 57 Preset 20 Store
29. is powered down the fixture will remain in the locked state when powered up Locking Fixture To lock the fixture Step 1 At Main Menu press MENU and scroll to Lock Fixture Note default PIN is 0000 four zeros Step 2 Press OK Step 3 Enter four digit user selectable PIN code Step 4 Use LEFT ARROW or RIGHT ARROW keys to highlight YES press OK or ESC twice to cancel action Step 5 Fixture is now locked if locking process was not canceled as described in previous step PHILIPS Selecon 18 OPERATION AND PROGRAMMING PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Note When the Fixture is Locked only the ESC MENU key is functional Pressing this key will display a request for a password When a valid PIN code is entered the fixture is unlocked 5 Presets Presets are Color Mixes that are stored in the Fixture they can be recalled to reproduce a specific output from the fixture Presets are made up of a Color Mix Red Green Blue and White They also have Intensity associated with them Presets can be recalled via the User interface or by a DMX channel when under DMX control The Preset s Intensity is applied if the User Interface is used if DMX the DMX Intensity channel is used for Intensity If the fixture is locked Presets cannot be changed at the menu Locked Presets are factory Calibrated and their Color Mix cannot be changed by the user Their Intensity can be
30. ition shown in Figure 6 you have full range access to shutters the gate etc If you flip the yoke over some access is reduced but the over all volume the luminaire takes up is reduced This is particularly useful in tightly hung lighting positions or in theatres with low grids SAFETY CABLE FOR LUMINAIRE the supplied safety cable is recommended for all hanging installation and may be required by national and local codes Loop attach safety cable to safety cable anchor point as shown and attach to structure Safety Cable supplied with luminaire Cooling Vents see note below Yoke Assembly Safety Cable Anchor Point T Handle Tilt Lock P NOTE To allow for proper cooling make sure luminaire head is orientated as shown q Sliding Yoke Assembly with cooling vents pointed upwards Figure 6 Luminaire Tilt Adjustment To adjust and set tilt angle of the luminaire Step 1 Mount luminaire in desired location see Mounting on page 9 for more information Step 2 Loosen but do not remove T Handle Tilt Lock at base of yoke assembly as shown in Figure 6 Step 3 Position luminaire to desired tilt position Step 4 Hand tighten T Handle Tilt Lock to set position PHILIPS 10 mstauamonanoseruP Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual FOCUS AND BEAM ADJUSTMENTS 1 Lens Tray Removal and Installation It is easy and quick to chang
31. l function and other functions follow in sequence 1 16 Mode Table 3 provides DMX channel mapping of all DMX512 control values when the PLPROFILEI LED Luminaire is in 16 bit DMX512 mode as set by the luminaire s menu system Table 3 PLPROFILE1 MKII LED Luminaire DMX Channel Mapping 16 Bit Mode Default DMX recommended Chann l Parameter Range DMX Range coris le default values Description Intensity High 0 65535 0 100 0 16 bit control for Intensity of LED settings Intensity Low Red High Byte Red Low Byte Green High Byte 0 65535 0 100 0 16 bit control of Red LEDs from 0 to full 0 65535 0 100 0 16 bit control of Green LEDs from 0 to full Green Low Byte Blue High Byte Blue Low Byte White High Byte White Low Byte 0 65535 0 100 0 16 bit control of Blue LEDs from 0 to full 0 65535 0 100 0 16 bit control of White LEDs from 0 to full oj jo o j o 5 o m Used to access presets stored in fixture firmware such as CCT presets defined gel presets etc No Preset Activated DMX 0 3 default Color Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Color Preset 3 Cool White DMX 16 19 Color Preset 4 Daylight DMX 20 23 Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Color Prese
32. m s cercana Der Inhalt dieses Handbuches ist nur f r Informationszwecke gedacht Aenderungen sind vorbehalten Philips Selecon uebernimmt keine Verantwortung f r Fehler oder Irrtuemer die in diesem Handbuch auftreten F r Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und oder Aktualisierungen in diesem Handbuch moechten wir Sie bitten Kontakt mit der naechsten Philips Selecon Niederlassung aufzunehmen Le mat riel d crit dans ce manuel est pour information seulement et est sujet changements sans pr avis La compagnie Philips Selecon n assume aucune responsibilit sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises jour de ce manuel veuillez s il vous plait contacter le bureau de Philips Selecon le plus proche Note Information contained in this document may not be duplicated in full or in part by any person without prior written approval of Philips Selecon Its sole purpose is to provide the user with conceptual information on the equipment mentioned The use of this document for all other purposes is specifically prohibited Document Number 02 9691 2001 Version as of 01 September 2015 MKII LED Luminaire Installation amp User s Manual 2015 Philips Group All rights reserved PLPROFILE1 MKII LED Luminaires Installation amp User s Manual IMPORTANT INFORMATION War
33. n amp User s Manual PLPROFILE1 MKII LED Luminaires Step 6 Hand tighten Focus Adjustment Knob to lock position Shutter 4 ea Zoom Adjustment Knob Lens Tray Assembly Focus Adjustment Knob Figure 8 Zoom and Focus Adjustment Knobs 3 Beam Shutter Operation Each PLPROFILE1 LED Luminaire is equipped with four independent shutters as shown in Figure 9 to block or shape light as desired After the luminaire is installed and positioned move the shutters in or out as desired Move beam shutters in and out as desired Beam Shutter 4 each Front View Figure 9 PLPROFILE1 MKII LED Luminaire Beam Shutters ZEE PHILIPS 12 FOCUS AND BEAM ADJUSTMENTS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual 4 PHILIPS Selecon Gobo Iris Access Panel Each PLPROFILEI LED Luminaire is capable of holding one gobo holder containing one M size glass steel gobo LED Luminaires are not supplied gobo holders an iris These items can be purchased from your local Authorized Dealer For more information refer to PLPROFILE1 LED Luminaire Imaging Accessories on page 4 To install or change a gobo Step 1 As shown in Figure 10 locate gobo iris access slot Step 2 Install gobo into gobo holder in desired orientation Step 3 Slide gobo holder into luminaire g
34. nings and Notices When using electrical equipment basic safety precautions should always be followed including the following a READ AND FOLLOW ALL SAFETY INSTRUCTIONS A Do not use outdoors Do not mount near gas or electric heaters Roc Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use This equipment is not for residential installation or use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disc
35. nnel individually and change their intensity using the UP and DOWN arrows Escape ESC Menu Button Enters menu options Navigates backs up one menu level Figure 11 LCD Display and Menu System 14 OPERATION AND PROGRAMMING PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual 2 LCD Menu System The LCD Display Menu system consists of several categories Use the four arrow buttons as required refer to Figure 11 on page 14 to access and make changes to the menu items When the desired menu item is reached press OK to display the menu options Use navigation and OK buttons to view status and configure the LCD Menu as required Note Refer to Menu Structure on page 16 for complete structure and settings To navigate and access menu settings selections Step 1 At Main Menu press ESC MENU button once Another window will appear with sub menu categories Save as Preset Edit a Preset Color Mixer Settings Lock Fixture Fixture Status Normalize Colors Step 2 Press OK at desired menu item to access and make changes Step 3 Make changes as desired Note When DMX512 signal is present Edit Preset and Color Mixer options will not appear in menu structure To navigate fixture status menus Step 1 At default screen press LEFT or RIGHT arrow button once The default menu screen will change to allow for quick reference to the following items note
36. obo slot making sure to catch slots in interior of gobo slot closest to shutters Gobo Iris Access Slot Gobo Holder Figure 10 PLPROFILE1 LED Luminaire Gobo Holder and Gobo Installation Gobo Iris Access Panel 13 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires OPERATION AND PROGRAMMING 1 LCD Menu Operation The PLPROFILE LED Luminaire s LCD Display and Menu System provides local control for accessing all the fixture s status information menu options and settings Note If there are multiple luminaires in a system changes would need to be made at each LCD Menu as desired Upon power up the LCD will display the main screen showing the product type name If DMX is enabled the programmed address will appear after power up OK Enter Button Accesses details activates a field or enters a setting depending on the current menu item LCD Display Displays all menu parameters and option settings Also displays DMX512 address DMX models only Up Down Left Right Arrow Buttons Navigates menu system and used for selecting and setting options PHILIPS Selecon PRESET INTENSITY PRESET Button Allows the recall of stored presets INTENSITY Button Allows the customization of current intensity light output Note using the LEFT and RIGHT arrow buttons you can select each RGBW cha
37. onnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Additional Resources for DMX512 For more information on installing DMX512 control systems the following publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suite 200 Syracuse NY 13210 1844 Phone 1 800 938 7488 or 1 315 463 6463 www usitt org Philips Selecon Limited Three Year Warranty Philips Selecon offers a three year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery A copy of the Philips Selecon three year limited warranty containing specific terms and conditions can be obtained from the Philips Selecon web site at www seleconlight com or by contacting your local Philips Selecon office LED Luminaire powerful LED engine offers exceptional performance and life Under normal operating conditions our LED engine has a life expectancy in excess of 50 000 hours however under worst case operating conditions with the luminaire set to continuous full output it is possible that a small percentage of LED s may require replacement sooner The Philips Selecon three year limited warranty includ
38. ough 31 changed 5 thru 25 an asterisk is appended to the end of the name to indicate that it has been modified This only happens if the name matches the original calibrated name stored in EEPROM This does not happen if the Intensity is changed only the color mix Note When DMX512 signal is present Edit a Preset option will not appear in menu structure Color Mixer Sub Menu Options Comments Red Users can Green Edit Red Green Blue White and Intensity values in percent by Select Color or Intensity to Adjust Blue using the arrow buttons Option Once the values are adjusted White press OK to save the edits to scratch pad Intensity Note When DMX512 signal is present Color Mix option will not appear in menu structure Settings Sub Menu Options Comments SETTINGS Option Scrolls and sets the various fixture settings using arrow buttons See Settings on page 19 for details Continued next page Menu Structure 17 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Menu Structure continued Continued from previous page Lock Fixture Sub Menu Options Comments Use arrow buttons to make selection Press OK to accept Note a PIN code must be established set in Enter PIN Lock Are you sure order to lock a fixture Locking the fixture will disable acce
39. r Powercon with PC1GR Edison Connector PLPROFILE1 MKII LED Luminaire PowerCon Male to PowerCon Female 2 5 Meter Cable for PC3PC interconnection between units PLPROFILE1 MKII LED Luminaire Zoomspot Lenses Part Number Description 15ACAX1834LT Acclaim Axial Zoomspot 18 34 Degrees Lens Tray Black 15ACAX2444LT Acclaim Axial Zoomspot 24 44 Degrees Lens Tray Black PLPROFILE1 MKII LED Luminaire Imaging Accessories Part Number Description 15ACGH Acclaim Axial Zoomspot Rotatable Gobo Holder Black Handle Steel M Sized Gobos 15ACGHGL Acclaim Axial Zoomspot Rotatable Gobo Holder Black Handle Glass M Sized Gobos 15ACIRIS Acclaim Axial Zoomspot Iris 15ACSM Acclaim Axial Zoomspot Lens Safety Mesh ACCDONUT Acclaim Axial Zoomspot Donut 20CFMF Acclaim Axial Zoomspot Replacement Color Frame 4 7 8 Inch Square Black PLPROFILE1 MKII LED Luminaire Clamps Part Number Description SC Selecon Molded Yoke Rated C Clamp MC Mega Claw Black Anodized PLPROFILE1 MKII LED Luminaire USB Luminaire Software Cable Part Number Description PEGASUS USB Luminaire Software Programming Kit for updating luminaire firmware includes USB Upload Cable QuickStart Guide and Carry Bag PLPROFILE1 MKII LED Luminaire Top Box Assembly Part Number Description PLICB Spare Top Box Interconnect Assembly PHILIPS dune Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s M
40. re DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 Preset 15 Store DMX 48 49 Preset 16 Store DMX 50 51 Preset 17 Store DMX 52 53 Preset 18 Store DMX 54 55 Preset 19 Store DMX 56 57 Preset 20 Store DMX 58 59 Preset 21 Store DMX 60 61 Preset 22 Store DMX 62 63 Preset 23 Store DMX 64 65 Preset 24 Store DMX 66 67 Preset 25 Store DMX 68 69 Preset 26 Store DMX 70 71 Preset 27 Store DMX 72 73 Preset 28 Store DMX 74 75 Preset 29 Store DMX 76 77 Preset 30 Store DMX 78 79 Preset 31 Store DMX 80 81 Preset 32 Store DMX 82 83 Color Normalization ON DMX 100 103 Color Normalization OFF DMX 104 107 Fixture Reset DMX 108 112 Red Correction ON DMX 113 115 Red Correction OFF DMX 116 118 NOTE Denotes default settings and return to default when performing control channel values 5 7 24 DMX CONTROL PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual 3 DMX 5 Channel 5 Chan Mode Table 2 2 provides DMX channel mapping of all DMX512 control values when the PLPROFILEI LED Luminaire is in 5 Channel 5 Chan DMX512 mode as set by the luminaire s menu system Note This mode is for the simplest control of the luminaire s LEDs and intensity for limited control consoles and controllers Table 2 2 PLPROFILE1 LED Luminaire DMX Channel Mapping
41. s illustrated in Figure 12 on page 35 unlatch the lens tray assembly Be careful as the lens tray assembly will swing open if not properly supported PHILIPS CLEANING AND CARE Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Lens Tube Assembly Lens Tray Assembly Lens Tray Latch Lenses Figure 12 Lens Cleaning Step 3 Apply a small amount of reagent grade isopropyl alcohol to lint free lens tissue Step 4 Wipe all debris dirt fingerprints etc from inside lens tube assembly and lenses Step 5 Using a second lint free lens tissue wipe off any alcohol residue Step 6 Re latch lens tray assembly 3 Service and Maintenance For all other service and maintenance issues please contact your local Philips Selecon office or an Authorized Service Center WARNING Disassembly other than as described herein alterations unauthorized service etc will void the product warranty Contact your local Philips Selecon office or an Authorized Service Center for technical support and service 4 Accessories Only Philips Selecon approved accessories should be used with your LED Luminaire For a list of available accessories from Philips Selecon please see Accessories on page 4 For questions regarding accessories please contact your local Authorized Philips Selecon Dealer or Philips Selecon office PHILIPS Selecon Service and Maintenance 35 Installation amp
42. ss to changing menu settings For details refer to Security on page 18 Fixture Status Sub Menu Options Comments Displays LED s current status in LED Status Information percentage of Intensity Red LED 1 Green Blue and White elements of Scrolls through the various levels the LED Fan Speed operational Depending on the arrow button LED junction temperature power pressed the screens may appear in a settings different order that shown in Displays DMX levels for each LED Options Levels element Red Green Blue and White and total power Normalize Colors Sub Menu Options Comments Allows for fine adjustments to color intensities for near perfect color matching Normalize Colors Adjustment of RGBW Intensities 4 Security Unwanted changes to the Fixture s Configuration or Setting can be controlled by locking the fixture s menu PLPROFILE1 LED Luminaires are shipped with a default numeric PIN code of 0000 four zeros Users may set their own PIN code four digit number via Settings gt General gt Set PIN When setting a PIN code write it down and keep it in a secure location Note Philips Selecon does not have records of PIN codes established by users or owners Note Contact Philips Selecon technical support if a unit is locked and the PIN code is lost for instructions on how to reset luminaire Note If the Fixture is locked when it
43. t 8 Daylight Blue DMX 36 39 Color Preset 9 Magenta DMX 40 43 Color Preset 10 Aqua DMX 44 47 Color Preset 11 Medium Amber DMX 48 51 Color Preset 12 Lavender DMX 52 55 Color Preset 13 Blue DMX 56 59 Color Preset 14 Light Pink DMX 60 63 Color Preset 15 Green DMX 64 67 Color Preset 16 Pink DMX 68 71 Color Preset 17 Amber White DMX 72 75 Color Preset 18 Dark Fuchsia DMX 76 79 Color Preset 19 Light Amber DMX 80 83 Color Preset 20 Steel Blue DMX 84 87 Color Preset 21 Lt Green Blue DMX 88 91 Color Preset 22 Orange DMX 92 95 Color Preset 23 Medium Pink DMX 96 99 Color Preset 24 Cyan DMX 100 103 Color Preset 25 Purple DMX 104 107 Color Preset 26 Custom DMX 108 111 Color Preset 27 Custom DMX 112 115 Color Preset 28 Custom DMX 116 119 Color Preset 29 Custom DMX 120 123 Color Preset 30 Custom DMX 124 127 Color Preset 31 Custom DMX 128 131 No Preset Activated DMX 253 255 11 Preset Color Selection 0 255 0 100 0 PHILIPS Selecon 16 Bit Mode 21 Installation amp User s Manual PLPROFILE1 MKII LED Luminaires Table 3 PLPROFILE1 MKII LED Luminaire DMX Channel Mapping 16 Bit Mode 12 Not used for future use 13 Intensity Time 0 255 0 100 255 Allows for luminaire timing of intensity Profile should default to DMX 255 for smoothest console fade t
44. the fixture using arrow buttons arrow buttons Once the values Cool White are adjusted the preset is saved Note To edit a current set preset as desired see Edit Presets Day Light Only intensities may be stored on White Color Temperature presets RGBW in these presets cannot be P t X 5 th h 31 reset edited or changed Continued next page RU PHILIPS 16 OPERATION AND PROGRAMMING Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual Menu Structure continued Continued from previous page PHILIPS Selecon Edit a Preset Sub Menu Options Comments Users can Off Edit the current settings look to a Select Preset to Edit Option Selects a current preset and outputs the preset so preset can be edited Note To save a specific look of the fixture see Save Presets For additional information refer to Presets on page 19 specific recallable Preset in the fix ture s memory Scratch Pad Edit the values for Red Green Blue White and Intensity values in percent by using the arrow Warm White buttons the values are adjusted the Save Preset menu option appears to save the edits Cool White NOTES Only intensities may be stored on White Color Temperature presets Day Light RGBW in these presets cannot be edited or changed Calibrated Preset s Color Mix is Preset X 5 thr
45. ture appears not to be operating at full brightness Luminaire has detected an over temperature condition The luminaire will reduce power to its LED if it senses that the LED is operating over the specified temperature LED temperature is read and recorded through a thermistor imbedded in the LED chip Fan is not operating Listen for fan operation or adjust settings to increase fan speed On luminaires with a display check system status menu for status of fans and LED operation Local programming Unit will not allow local programming or changes Password protection is on locked Input proper password to allow local programming and or adjustments Unit is controlled by DMX Disconnect input cables to check issue TROUBLESHOOTING PHILIPS Selecon PLPROFILE1 MKII LED Luminaires Installation amp User s Manual TECHNICAL SPECIFICATIONS 1 PLPROFILE1 MKII LED Luminaire Operational Specifications Source True RGBW 120 Watt LED chip Light Output gt 2000 lumens Beam Angle 18 34 Degrees or 24 44 Degrees depends on lens option purchased Power Consumption 140 Watts max RGBW at 100 Input Voltage 100VAC to 240VAC 10 auto ranging Current 1 2 Amps 115VAC 0 6 Amps 230VAC Frequency 50 60Hz Ambient Temperature 0 to 40 degrees C 32 to 104 degrees F Humidity 596 9596 Non condensing Cooling Forced Air Weight 17 2 lbs 7 8 kg Luminaire and topbox only no mount
46. ved for cleaning The LED Luminaire special care when it comes to cleaning front lens assembly Additional care needs to be taken with the plastic components because they are much easier to scratch or damage than glass The following is a list of cleaning materials required to care for your PLPROFILE1 MKII LED Luminaire Lint free lens tissue Lint or powder free gloves Reagent grade isopropyl alcohol A mild soap solution Note Reagent grade isopropyl alcohol is good to use on the PLPROFILE1 LED Luminaire optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optics then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the PLPROFILEI LED Luminaire These types of cleaners or solvents can permanently damage the optics or housings of the fixture If you have any questions regarding the use or care of your PLPROFILEI MKII LED Luminaire please contact Philips Selecon technical support or your local Authorized Dealer Lens Tray Assembly Cleaning To clean the front lens Step 1 Turn off luminaire and allow to cool completely Step 2 A
47. y Locations Only Certified to CSA E598 2 17 Made in U S A Impropre A L usage Domestique Pour Emplacements Secs Tc 60 C e Ta 40 C e IP20 www seleconlight com Seulement No User Serviceable Parts 04 9691 0203 a Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector Doit tre aliment par un circuit de d rivation prot g par un maximum de 20 amp res circuit protecteur b When using the daisy chain connection method ONLY connect PLPROFILEI MKII LED Luminaires to AC Output Connection of PLPROFILEI LED Luminaires DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES Use only approved cable types Do not overload circuits Do not connect PLPROFILE1 LED Luminaires to dimmed circuits The MAXIMUM allowable number of PLPROFILE LED Luminaires which can be daisy chained on one power feed should not exceed ratings DO NOT EXCEED 00 Connecting Power Units can be powered in one of two ways Direct connection to a AC power source using an AC input cable Daisy chain connection using a interconnect AC cable If the unit is supplied with an AC input cable but you did not order an AC input connector Table 1 on page 8 describes how to connect power to your PLPROFILEI LED Luminaire Field wiring of the PLPROFILEI MKII LED Luminaire is straight forward A total of 3 wires conductors need to be brought to the unit The following wiring scheme is required

Download Pdf Manuals

image

Related Search

Related Contents

ADR Guide - Merging Technologies  取扱説明書  System and method for context-sensitive help in a design environment  Mellanox OFED Linux User`s Manual    PNY 16GB Micro Attache    液面計の不具合に起因した危険物流出事故調査について 危険物保安  TP-Link TD-W8951NB User's Manual  PDFファイル  

Copyright © All rights reserved.
Failed to retrieve file