Home

USER MANUAL - Tanning Bed Parts

image

Contents

1. 12 Remote Connections 13 Operation enia sr ot 6 16 Befor YOU Tatts sek PREX Ea 1 tha 16 Exposure TIMES eser cu aia SW alert as Ga Ee oA 16 Using Your Sunbed 17 Care and Maintenance iiec ceed 6809 64 eee s 19 Cleaning After USS site s balan phe ean adn 19 Thorough Periodic Cleaning 19 Mechanical Inspection 19 Lamp and Acrylic Replacement 20 Troubleshooting 23 v Ae CC AP jet Information LABELING NOTICE Labels are affixed on all systems to inform the user of possible dangers Regulations are stated in 21 CFR Section 1040 20 and require that all products manufactured after September 8 1986 which use sunlamps must display the following D ANGE Ultraviolet radiation Follow instructions Avoid overexposure As with natural sunlight overexposure can cause eye and skin injury and allergic reactions Repeated exposure may cause premature aging of the skin and skin cancer WEAR PROTECTIVE EYEWEAR FAILURE TO MAY RESULT IN SEVERE BURNS OR LONGTERM INJURY TO THE EYES Medications or cosmetics may increase your sensitivity to the ultraviolet radiation Consult physician before using sunlamp if you are using medications or have a history of sk
2. lo N SCREWS RETAINING 22 Problem Sunbed not tanning Lamps fail to light and timer dis play is blank One or more lamps fail to light The canopy will not stay up The face tanners will not come on The last minute of tanning time does not count down from 59 sec onds but some time less than 59 seconds forgot what address or id set my sunbed to 23 av y ET roubleshooting Solution Clean sunbed see Thorough Periodic Cleaning Ensure supply voltage is between 208 and 230V AC Replace lamps if lamp hours are greater than 800hrs Replace acrylic Make sure the unit is connected to a power source Check source of AC power Reset circuit breaker or replace fuse Check that lamp is installed correctly Switch unlit lamp with a lamp that lights if new lamp lights and old lamp still does not replace old lamp NOTE Gas springs are manufactured to hold the canopy in its fully open position as well as allow it to rest fully closed If left open for an extended period of time some creep down may occur This is considered normal Keep the unit closed when not in use If the canopy will not stay fully open when raised Raise and lower the canopy a few times to lubricate gas spring internal seals Replace gas springs
3. X Installation Assembly Procedures 4 f DJ ES Ly X 286 Installation Assembly Procedures ma Install Gas Springs 3 Screw the upper clevis forks onto the Have a helper hold the canopy in its gas springs fully open position Do not lower the canopy yet Make sure the threaded holes in the lower clevis forks face up the large holes above the clevis forks allow fin ger access Slide the gas springs down into the stand uprights piston end up as shown and twist the gas springs into the lower clevis forks until they are snug V10 Z08SZ 25802 01A ue Installation Assembly Procedures A R ma Attach Gas Springs 1 With the canopy still raised slip the bronze bushings into the hole in the clevis brackets on the underside of the canopy arms 2 Line up both clevis forks and carefully lower the canopy to engage the clevis forks Pay special attention when low ering the canopy that the clevis forks do not damage the bronze bushings Bronze is excellent for smooth pivot ing applications such as this but tends to be soft compared to the steel clevis fork Clevis Bracket 3 Lock the clevis forks in place with the 10mm clevis pins 4 Secure the clevis pins with the retaining rings NOTE When this assembly is complete lift and lower the canopy a few times to lubricate the gas springs for optimum per forman
4. Limited Lifetime Warranty SUNVISION warrants your tanning unit to be free of structural defects in its material and workmanship under normal use for its lifetime SUNVISION will repair or replace at their discretion any defect to the structure which affects the performance of the unit For 6 months from the date of purchase SUNVISION will provide replacements for parts that prove to be defective in material or workmanship Acrylic shields fluorescent lamps and lamp starters are excluded from this warranty Labor will be covered for 30 days from purchase date Normal wear damage from misuse or abuse damage incurred in transit or damage done by unauthorized repairs or modifications are not covered by this warranty ETS Inc disclaims any implied warranty of merchantability or fitness for any period beyond the expressed warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you No one has authority to change or modify this Limited Lifetime Warranty in any respect To obtain service under the Limited Lifetime Warranty contact ETS Inc at 1 800 449 3605 and ask for the Technical Service Department ETS Inc shall not be liable for loss of use loss of time inconvenience rental or substitute products loss of business loss of income or any other incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or
5. 9 Your skin should be free of cosmetics tanning oils or other body lotions prior to tanning except for those specifically made for use with tanning devices However do not remove nat ural body oils by bathing or showering immediately before tanning Your hair should be free of gels mousses sprays or other hair products prior to tanning These products can cause damage to the sunbed acrylic As an alternative a shower cap or towel can be worn to keep treated hair away from the sunbed surfaces This unit intended for individual use Only one pair of eyewear is included RECOMMENDED EXPOSURE TIMES IN MINUTES Level 1 Week 1 1st 3rd Sessions Skin Type I Sensitive Skin Burns easily and severely and does not tan Light A DANGER Some medication may increase your sensi tivity to ultraviolet light It is recommended that you consult a physician before using this sunbed if taking any medication or if you suspect that your skin might be especially sensitive to sunlight DANGER Shock hazard Do not operate this device near water or while you are wet Exposure Times Follow the guidelines for skin type and exposure times as shown in the table below Untanned persons should not tan on consecutive days during their first week of tanning Never tan more than once a day Tanning normally appears after the first few sessions and maximizes after approxi mately four weeks Tan once or twice per week
6. 2E h INS ZE 63 A OS d Q lt gt CAPACITOR CONNECTION PCB CONTACTOR CURRENT SENSOR REMOTE REMOTE PCB TO TIMER LAMPHOLDER W STARTER WIRING HARNESS STARTER 2 LAMPHOLDER MOUNTING ARM W O STARTER CANOPY u 88 2 g P ES 2 gt 25 Dui E Ww 2 A SE M 7 og m ZN Mpa A DY i JA N y mo LAS VR 5 22 Z W O ur 5 nes Qu Y C 2 Ms N 30 ANA E c Y SAN p i cz SN N R Es 2 SIA 22 z NIS ou 23 lt Nov 77e O qg N i E W ET cx 2 Oo 59 9 406 W f MN lt lt ro MN j 5 LES NOMEN L LANE NWO ID Li E x e KI A a 5 282 E BUIN Y Va WY a zi j amp z pg U 3 7 xo y gum O Z Y ur zv O lt Al S TRE ox ue 8 zz V10 Z08SZ 25802 01A Parts List This is a list of parts which may be replaced by the consumer Care should be taken when replacing anything related to electrical wiring We recom mend contacting a professional electrician When calling for parts first state your bed model as N ZX30 or N ZX30 3F Then refer to this list and pre ceding illustrations for proper part identification Acrylic Bench Acrylic Canopy Ballast 100W Ballast Face Tanner 400W Bushing Bronze 10mm Body Fan Kit optional Canopy Mounting Arm Capacitor 75uF Contactor Relay Contactor for Face Tanner Cover Bench Cove
7. room temperature should be 80 F sional electrician Place your sunbed no closer than 6 from any wall Make sure nothing e IMPORTANT Voltage must be obstructs the airflow into the sunbed s endcaps or out of the fan Buck Booster openings A poorly ventilated room may cause the unit to become hot and cause discomfort to the user below 230V AC or may require a A CAUTION Proper assembly of your sunbed requires three people Plan to have a couple of helpers assist you ay w a va A R Installation Hardware Inventory Hardware Inventory Use the utility knife to cut open the hard ware bag Remove the hardware Make sure you have the following items Clevis Pin 3 8 x 2 1 64 Quantity 2 Bridge Pin Quantity 4 Clevis Fork M10 Long N Quantity 4 Centering Spring Quantity 4 1 4 20 x 1 2 Machine Screw Quantity 8 e 1 4 20 Locknut Quantity 8 Nylon Floating Bearing Quantity 4 0 Clevis Pin 5 16 x 2 1 32 Quantity 2 Retaining Ring Quantity 2 10mm Clevis Pin Quantity 2 Bronze Bushing Quantity 2 10 x 1 2 Screw Blue Head Quantity 8 gt gt 10 x 1 Screw Quantity 3 Safety Goggles Quantity 1 V10 20857 25802 01A ay Installation Assembly Procedures MS 2 Assembly Procedures Lower Clevis Fork Assembly NES 1 Insert the larger clevis pin 3 8 x 2 1 64 through the hole directly below v
8. thereafter to maintain appearance Persons already having a base tan may begin at advanced levels corresponding to the extent of their base tan MAXIMUM EXPOSURE TIME IS 20 MINUTES Subsequent Level 4 Maximum Level 2 Level 3 NOT RECOMMENDED FOR TANNING Burns easily and severely and tans minimally 4 8 12 16 20 III Normal Burns moderately and tans average IV Dark 6 10 15 20 20 Burns minimally tans easily and above average 8 12 16 20 20 16 ay M Operation Using Your Sunbed Using Your Sunbed When connected to the T Max Manager or T Max 1A or 3A AN 38 em 0 A B C D E F G Face tanner control Turns face tanners on and off during use Face tanner lamps reguire one minute to relight Units eguipped with face tanner only Body tanner control Turns body lamps on and off during use Units eguipped with face tanner only Body fan control Controls the speed of the body fan during use Body fan speed indicator ndicates speed of fan OFF LOW MED HI Timer display Displays remaining time Stop button nterrupts tanning session Timer button Turns bed on Timer dis play shows remaining time If a lesser time is desired press timer button until desired time is displayed A WARNING Wear protective eyewear Failure to may result in severe burns or longterm injury to the eyes Lift the canopy lie down on the bench face up lower the ca
9. wish to save them for future use As you unpack your boxes you should find the following e Canopy unit e Bench unit e Pair of gas springs e Front skirt panel Bag containing necessary assembly hardware safety goggles opening handle and pillow e Gas spring cover panel Inspect these items including the canopy and bench and make sure they are free from any visible damage Report the extent of any damage to the transportation company Record the serial numbers of the canopy and bench in the area provided at the back of this manual This information will be required whenever you call customer service Tools Required You will need the following tools to assemble your sunbed Utility Knife 2 Phillips Screwdriver a 7 16 Wrench V10 Z08SZ 25802 01A Installation Pre Installation Planning A R ma Pre Installation Planning Before you begin to assemble your sunbed you should observe the following consid erations A WARNING CAUTION Shock hazard Use of a voltage source above 230V Disconnect power before AC may prevent proper operation of servicing the sunbed and could cause damage and void the warranty e The SUNVISION ZX30 series reguires a dedicated circuit capable of providing 30 Amp service at A CAUTION 220VAC This unit must be hard Air from the room is used to cool wired directly to a junction box We the sunbed Maximum ambient recommend connection by a profes
10. Face tanner operation is initially delayed by 5 seconds Face tanners will not relight for 1 minute if turned off Replace face tanner lamp see Removing Replacing Face Tanner Lamp on F Models If the timer button has been pressed to decrease tanning time during the session the time expired in the current minute is subtracted from the last minute By holding the body fan button for 3 seconds the timer display will briefly display three numbers the installed timer software version a factory set timer code and then the sunbed s id number VLO cO8SZ 25802 01A ue Troubleshooting 72 A Problem Solution Timer display is indicating Er 91 Timer software error Disconnect and reapply power to the unit Timer display is indicating Er 92 Current sensor indicating unit is off when it should be on Contact servicer Timer display is indicating Er 93 Current sensor indicating unit is on when it should be off Contact servicer Timer display is indicating Er 94 Requested session time exceeds maximum time allowed Timer display changes to indicate 1 Bypass plug is not installed see Electrical Connections a tanning time after the timer but 2 non SunStar bypass has been used See Electrical ton is pressed but lamps do not Connections come on 3 If remote is being used other than T Max amp Manager the exter nal timer may not be activated 4 Remote wiring is incorrect see the instructions provided with
11. NOTE Your sunbed is designed to accept an input from a remote control device The remote control is optional If you plan on using a remote system refer to Remote Connections ATTENTION Although the Remote Control Bypass plug provided with your sunbed will work wherever a T Max ter minator is called for in the series the T Max terminator will not work as a bypass plug A bypass plug is needed only when your sunbed is operated without a remote system connected Remote Control Ports Remote Control Bypass plug 12 NY 200 AN A Installation Remote Connections Remote Connections Your sunbed incorporates advanced circuitry allowing it to connect and communicate with most remote control systems If a remote sys tem is to be used first determine whether the remote system is a T Max amp System or a stan dard remote system operating with a control relay Follow the appropriate instructions for your system type CAUTION The remote connection is not designed to supply or accept high voltage nor can it provide power to an external timer The sunbed s remote inter face circuitry operates on 5 volts attempting to connect it to any higher voltages will damage the sunbed as well as void your warranty T Max Manager incorporated units figure 1 13 T Max Products The T Max remote systems offer the ultimate in sunbed control while allowing the tanner easy strai
12. UIPMENT Velocity Wolff Model VEL 71 T12 100W Heraeus E400 HPT Philips Model HPA 400 30s or CosmoTech Model 23045 SolarMax IFT facial unit in ZX30 3F 21 10 085 25802 01A Care and Maintenance Lamp and Acrylic Replacement A N Removing Replacing Face Tanner Lamp on F Models After removing the canopy acrylic shield replace the face tanner lamp as follows Step 1 Support the face tanner assembly with your hand while unscrew ing the two retaining screws The face tanner glass casing will swing downward Step2 The lamp can now be exchanged The lamp holders are equipped with spring con tacts which enable the lamp to be removed easily Remove the old lamp and discard Install the new lamp using a clean cloth or paper towel Ensure that the lamp is firmly seated in the lamp holders W ES KUSI Note Never take hold of the lamp such that your fingers are in contact with the lamp glass Finger oils will greatly reduce the lamp s operational life Step 3 Gently close the face tanner glass casing and lock it closed with the screws Ensure that the screws firmly secure the glass casing DANGER Unfiltered light from face tanner can cause severe burns Never turn sunbed on while face tanner is disassembled or when glass filters are removed Immediately discontinue use of this equipment if face tanner glass is broken or any unfiltered light can be seen escaping face tanner assembly
13. ada call 1 800 661 6292 or 519 469 3166
14. ans les panneaux de plastique transparents La premi re semaine de bronzage les personnes qui n ont pas un h le initial ne doivent pas se faire bronzer tous les jours Ne vous faites jamais bronzer plus d une fois par jour Le bronzage commence normalement appara tre apr s les premi res s ances il atteint son apog e au bout d environ quatre semaines Les personnes qui ont d j un teint h l peuvent commencer des niveaux plus lev s selon l importance de leur h le initial TEMPS D EXPOSITION RECOMMAND EN MINUTES LE TEMPS D EXPOSITION MAXIMAL EST DE 20 MINUTES lev 1 Semaine 1 Sem suivantes 1 lev 2 lev 3 lev 4 Temps maximal Type de peau Peau sensible br le facilement et ne bronze pas NON Ecoma II Peau claire br le facilement et bronze tr s peu III Peau normale br le et bronze de fa on mod r e Peau fonc e br le tr s peu bronze plus facilement que la moyenne Les neuves mettent approximativement 10 de Tp de rayons ultraviolets au cours des 50 premi res heures de fonction nement Le temps de bronzage doit donc atre r duit d environ 10 pendant cette p riode AVERTISSEMENT Lisez le livret d instructions avant d utiliser cette lampe solaire Les autres personnes pr sentes dans la pi ce doivent aussi porter des lunettes protectrices lorsque les lampes sont allum es Coquilles de protection pour les yeux recommand es Les coquilles de protection fournies ou l quival
15. ce ay Ly A cai Installation Assembly Procedures fq Attach Cover Panels 1 Putthe gas spring cover panel in place and secure with two blue headed 10 x 1 2 screws in each end The skirt installs in the same way 10 089 25802 01A ay Installation Assembly Procedures A ma Attaching Handle to Canopy Install the handle by inserting the three 10 x 1 Phillips head screws through the handle and into the predrilled holes on the canopy w A Installation Assembly Procedures ma Body Fan Assembly body fan sold separately A WARNING Shock hazard Be sure power is disconnected before installing body fan Your sunbed is designed to accept a body cooling fan on the canopy endcap at the foot end Follow the instructions that come with the body fan for installation V10 Z08SZ 25802 01A Electrical Connections At the rear of the bed insert canopy plug A into bench socket B Connect power cord C as described in Pre Installation Planning Again a professional electrician is recommended The Remote Control Bypass plug is already installed in one of the remote control ports as shown Your sunbed will not operate without the Remote Control Bypass plug or a remote system connected Remove the protective film from the acrylic shields Your equip ment is now ready for use Y Installation Electrical Connections S CS
16. consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state All warranty service must be performed by an authorized service person If your tanning unit must be returned for service all freight charges must be at your expense Contact your place of purchase for the address of the SUNVISION Service Center nearest you Proof of purchase is required to obtain warranty service This warranty covers the original purchaser only This warranty is void if the unit is modi fied in any manner from its original design VLO cO8SZ 25802 01A Me AN Congratulations on your purchase of this technologically advanced sun tanning unit It has been SU Some designed to provide years of dependable service Please read all the instructions in this booklet before installing and using the unit Always be sure to observe all s afety precautions D A Moe ts ve D Safety Information iii nstallanOn 2 2 Sue perea a aa ete E ae es 1 Unpacking and Inspection 1 Tools Required nus esere iia 1 Pre Installation Planning 2 Hardware Inventory 3 Assembly Procedures 4 Electrical Connections
17. e exposition excessive peut causer des blessures aux yeux et a la peau et provoquer des r actions allergiques Une exposition r p t e peut causer le vieillissement pr matur de la peau et provoquer le cancer de la peau PORTEZ DES LUNETTES PROTECTRICES LE NON RESPECT DE CETTE CONSIGNE DE SECURITE PEUT ENTRAINER DE GRAVES BRULURES OU DES LESIONS OCULAIRES A LONG TERME Les m dicaments ou les produits cosm tiques peuvent aug menter votre sensibilit au rayonnement ultraviolet Consultez un m decin avant d utiliser la lampe solaire si vous prenez des m dica ments si vous souffrez d une maladie cutan e ou si vous croyez tre particuli rement sensible aux rayons du soleil Si vous ne bronzez pas au soleil il est peu probable que vous bronzerez sous une lampe solaire Les enfants les personnes g es et les personnes qui ont une peau claire qui br le facilement ne bronze jamais ou alors tr s peu ne devraient pas utiliser cette lampe Etendez vous sous la partie sup rieure puis abaissez celle ci aussi bas que possible en veillant cependant conserver un espace d au moins 1 pouce 2 5 centim tres entre le corps et le panneau de plastique transparent de la partie sup rieure afin d viter une exposi tion excessive La distance minimale d usage de l appareil de bronzage pour le visage si muni est de 4 pouces 10 2 centim tres Les autres parties du corps peuvent toucher les panneaux de plastique transparents N utilisez pas la lampe s
18. ed s bench and canopy after each use Use a non abrasive disinfectant cleaner that does not contain ammonia or ammonia deriva tives Ammonia may damage the acrylic shield Spray the acrylic lightly with disin fectant and wipe dry with a clean soft cloth We recommend SunQuest disinfectant and SunQuest acrylic cleaner Thorough Periodic Cleaning Introduction The cooling fans draw air through the bed and over time will cause a dust buildup on the lamps and reflectors This will reduce the tanning effectiveness of the bed When a dust buildup is observed it is necessary to thoroughly clean the inside of the bench and canopy WARNING Shock hazard Disconnect power before removing any protective covers Cleaning the Canopy and Bench Step 1 Remove the acrylic shields and lamps as described in Lamp and Acrylic Replacement 19 Step 2 With a soft cloth wipe the entire length of each lamp to remove any film buildup Clean both sides of the acrylic shields with a non ammonia dis infectant cleaner Wipe the reflectors with a clean damp cloth Re install the lamps and acrylic shields Step 3 Step 4 Step 5 Mechanical Inspection Your tanning bed has been built for years of service To ensure trouble free operation throughout its life inspect the unit s mechanical integrity every 400 500 hours of use Inspect the units fasteners verifying that all are firmly in place Inspect gas springs for s
19. ent tel que le stipule le document 21 CFR 1040 20 Les autres types de lunettes pro tectrices peuvent ne pas assurer une protection ad quate Utilis sans lunettes protectrices ce produit peut causer des br lures ou l sions oculaires graves Si vous souffrez d un malaise arr tez l utilisation et consultez un m decin SEULES LES LAMPES SUIVANTES ONT T HOMOLOGU ES POUR CET QUIPEMENT Velocity Wolff amp Mod le VEL 71 T12 100W Heraeus E400 HPT Philips Mod le HPA 400 30s ou CosmoTech Mod le 23045 unit faciale ZX30 3F D brancher l alimentation lectrique avant de nettoyer l appareil d en faire l entretien ou de changer les lampes 4 Cet quipement doit tre mis la terre Ce produit est conforme aux normes de rendement pour les lampes solaires dans le documents 21 CFR partie U Cll 1040 20 ANSI UL 482 CAN CSA C22 2 N 224 88465 WM sts ae Bq nstallation Unpacking and Inspection Your sunbed comes in two cardboard car tons one for the bench and one for the canopy Open the cartons and remove the bench and canopy as follows The bench and canopy are each wrapped in plastic Pull back the plastic and with a helper grasp the bench and pull it from the carton bottom leaving the plastic wrap and the carton packaging Do the same for the canopy Do not attempt to lift either unit with the plastic still on as it may slip Note The cartons are reusable You may
20. ghtforward operation Your sunbed is configured to directly connect to this system The circuitry inside your sunbed eliminates the need for the T Max 1A or 3A when connect ing to the T Max Manager series Your sunbed supports the auto addressing feature of the latest T Max Manager models and the fol lowing parameters 2 5 6 7 8 9 10 14 15 and 23 See your T Max manual for descrip tions of these parameters and how they func tion See Troubleshooting My salon suf fers for information about parameter 23 T Max amp Manager Remote System This system is ideal for multiple sunbed instal lations Simply connect the RJ 22 modular cable s described in the T Max amp Manager manual into the remote port s located on the back of your sunbed and follow the instruc tions that came with your remote system not ing figure 1 If you have an older T Max Manager that doesn t support auto addressing set the address or id of each sunbed manually as described in Setting the address manually You can place your sunbed at any location in the series NOTE A T Max 1A can be substituted for the 3A in figure 1 V10 Z08SZ 25802 01A T Max 1A and 3A Remote Systems In single sunbed installations the T Max 1A and 3A can offer the same control as the T Max Manager eliminating the need for a Manager If you re using a 1A in this manner it must have a chip labelled master installed on its circ
21. igns of wear Gas springs that will not hold the canopy in the full open position when raised should be immediately replaced See Troubleshooting Inspect the AC power cord and its connections Inspect the acrylic Broken cracked or badly scratched acrylics should be immediately replaced V10 Z08SZ 25802 01A Care and Maintenance Lamp and Acrylic Replacement N Lamp and Acrylic Replacement Introduction To be assured of maximum tanning effec tiveness change lamps after approximate ly 800 1000 hours of use Tanning will continue after this time but at a slower rate To ensure trouble free operation of your sunbed replace the lamp starters whenever the lamps are replaced A WARNING Shock hazard Disconnect power before servicing 1 Removing Replacing Acrylic Shield The acrylic shield in the bench and canopy are secured in place by hinged profiles which run the length of the bed both front and back Simply pry up on the inside edge of the profile starting at the center of the bed until it releases its latch ing action see figure at right Continue to pry up the profile across its entire length until it swings back freely Repeat for the other profile The long edges of the acrylic shields are now exposed D KUSI Standing at the front of the unit lift the exposed edge of the acrylic slightly and carefully begin sliding it toward you until it is removed from the sunbed This
22. in problems or believe yourself especially sensitive to sunlight If you do not tan in the sun you are unlikely to tan from the use of this product Children the elderly or fair skinned people who always burn easily and either never tan or tan minimally should not use this equipment To use lie down under canopy and pull down as far as adjustment will allow maintaining at least 1 inch 2 5 centimeters between your body and canopy clear plastic panel otherwise overexposure may occur Minimum use distance from face tanner if equipped is 4 inch es 10 2 centimeters Minimum use distance elsewhere is touching the clear plastic panels Do not use without clear plastic panels in place Untanned persons should not tan on consecutive days during their first week of tanning Never tan more than once a day Tanning normally appears after the first few sessions and maximizes after approximately four weeks Tan once or twice per week thereafter to maintain appearance Persons already having a base tan may begin at advanced levels corresponding to the extent of their base tan RECOMMENDED EXPOSURE TIMES IN MINUTES MAXIMUM EXPOSURE TIME IS 20 MINUTES Level 1 Week 1 Subsequent Level 2 Level 3 Level 4 Skin Type 1st 3rd Sessions Maximum I Sensitive Skin Burns easily and severely and does not tan NOT RECOMMENDED FOR TANNING II Light Burns easily and severely and tans minimally 4 8 III Normal Burns moderately and tans average 10 15 IV Dark Burns m
23. inimally tans easily and above average 12 16 New lamps emit approximately 10 more ultraviolet radiation during the first 50 hours of operation Recommended tanning times should therefore be reduced by approximately 1096 during that period WARNING Read the instructions booklet before using this sunlamp product All persons in the room should wear protective eyewear when lamps are on Recommended eyewear provided eyeshields or equivalent eyewear as defined under 21 CFR 1040 20 Other types of eyewear may not provide adequate protection Failure to use protective eyewear may result in severe burns or other eye injury If dis comfort develops discontinue use and consult a physician ONLY THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE IN THE ZX30 SERIES Velocity amp Wolff amp Model VEL 71 T12 100W Heraeus E400 HPT Philips Model HPA 400 30s or CosmoTech Model 23045 SolarMax IFT facial unit ZX30 3F DISCONNECT POWER BEFORE ATTEMPTING TO CLEAN RELAMP OR ENGAGE IN THE MAINTENANCE OF THIS PRODUCT THIS EQUIPMENT MUST BE EARTH GROUNDED This product is in conformity with performance standards for sun lamp products under 21 CFR PART 1040 20 and ANSI UL Standard 482 Certified to CAN CSA Standard C22 2 NO 224 c us LISTED i 88465 V10 Z08SZ 25802 01A Safety Information D AN GE Rayonnement ultraviolet Veuillez suivre les instructions Evitez une exposition excessive Tout comme pour les rayons du soleil un
24. l Controls the speed of the body fan during use Body fan speed indicator ndicates speed of fan OFF LOW MED HI Timer display Displays remaining time Stop button Stops tanning session Timer button Turns bed on Timer dis play shows remaining time If a lesser time is desired press timer button until desired time is displayed A WARNING Wear protective eyewear Failure to may result in severe burns or longterm injury to the eyes 1 Lift the canopy lie down on the bench face up lower the canopy toward your body using the canopy handle See Safety Information for positioning instructions Put on your safety goggles Press the timer button G to begin the tan ning session The lamps will turn on and the timer will begin to count down If a tanning time less than the displayed time is desired repeatedly press the timer button G to decrease the remaining time When the timer reaches O the lamps turn off If you want to stop your session before time expires press the stop button F You will have ten seconds to restart with the remaining time otherwise the timer will reset to 0 Raise the canopy by using the outer edge of the canopy do not push up on the acrylic shield The cooling fans run for a period of time after the lamps shut off to aid in cooling the sunbed 18 M w e CA and Maintenance Cleaning After Use Clean and disinfect your tanning b
25. might be easier with the help of another person After changing the lamps replace the acrylic shield by carefully aligning it with the channels on the ends of the sunbed and sliding it into place Close the hinged profile by pushing it back into place until it snaps tight A CAUTION Be careful The edges of the acrylic shield may be sharp uie 2 RE Removing Replacing Lamps After removing the acrylic shield replace lamps as follows Step 1 Grasp the lamp at one end and at the middle and turn the lamp one quarter turn Gently remove the lamp from its holders Step 2 Reinstall the lamp by inserting the pins located on the ends of the lamp into the slots on top of the lamp holders and turn the lamp a quarter turn It should click in place La Care and Maintenance Lamp and Acrylic Replacement Recommended Replacement Lamps We recommend using the lamps specified below Use of uncertified lamps is a viola tion of Federal regulations and will void your warranty These lamps have an aver age life of 800 1000 hours of effective tanning use Lamps used longer than that begin to lose their effectiveness even though they continue to light Recommended Replacement Acrylics Acrylics vary greatly over time in their ability to effectively transmit UV light Acrylics sold by ETS have been life tested to ensure proper transmission throughout their useful life ONLY THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE INTHIS EQ
26. nnect the remote plug s from the ports at the back of the sunbed wait 90 seconds and try again Remote device has not been set The sunbed has not been connected to the remote system see Remote Connections Delay time of TMax Manager has not been set Delay time has expired and session has begun Auto start function of T Max Manager has been turned off Press the timer button to turn on lamps When using the auto address feature of the T Max Manager you must wait 10 seconds from the time you start the auto address function before addressing the first bed SunStar Bypass plugs or terminator plugs may be needed if the T Max 1A and the sunbed are over 100 feet apart Install the plugs in the open remote port in the sunbed and the T Max 1A If you have a T Max Manager changing parameter 23 from 0 to 1 will allow the tanning bed to remember how much time was left when power goes out and resume its session after power is restored Consult your T Max amp Manager manu al for information on setting parameters V10 Z08SZ 25802 01A ue Notes S ue Ly RE La Notes V10 Z08SZ 25802 01A E Ww 1 2 lt ar ji ax d mu Z 0 9 lt N gt Su i I Am xa E S O lt E IL d an i 1 SILK SCREENED PROFILE FRENCH WIRING HARNESS KEYPAD TO TIMER Ww EE OCT N NN NY VIN FA LD ANNA TS 0 IN Y
27. nopy toward your body using the canopy handle See Safety Information for positioning instructions Put on your safety goggles 3 Assuming the remote system has been set to allow a pre tanning delay time the timer display E will repeatedly flash the delay symbol dL and then the remaining delay time Press the timer button G or wait until the delay time has expired to begin the tanning session The lamps will turn on and the timer will begin to count down When the timer reaches O the lamps turn off If you want to stop your session before time expires press the stop button F Raise the canopy by using the outer edge do not push up on the acrylic shield The cooling fans run for a period of time after the lamps shut off to aid in cooling the sunbed The timer will indicate as a reminder to clean the sunbed After the sunbed is cleaned press the timer button and the display will return to 0 VLO cO8SZ 25802 01A Using Your Sunbed When used as a stand alone unit or when connected to a remote system using a control relay wee Operation Using Your Sunbed A a oe ep 8 C E F G Face tanner control Turns face tanners on and off during use Face tanner lamps require one minute to relight Units equipped with face tanner only Body tanner control Turns body lamps on and off during use Units equipped 3 with face tanner only Body fan contro
28. r Canopy Endcap Kit with inserts Fan Gas Spring Cover Panel Gas Springs Handle Hardware Kit Hour Counter Keypad Assy Kit Lamp Holder w Starter Lamp Holder w o Starter Lamp Holder Face Tanner Lamps Manual Pillow Profile blank Remote Connection PCB Remote Control Bypass Plug Schematic Packet Silk screened Profile English Silk screened Profile French Skirt Starter K 12 main lamps Starter Face Tanner ignitor Thermostat for face tanner Timer Trim Profile grey Wiring Harness Keypad to Timer Wiring Harness Remote PCB to Timer Not shown Record this information for ease of service Date of purchase Bench serial number Canopy serial number ZX30 ZX30 3F Size 53 ik a Weight Pounds 476 Minimum Room Size XI Electrical Voltage AC 220 220 Amperage 17 22 Circuit Breaker Amps 30 30 Outlet Hardwire Hardwire Main Lamps Velocity 100W Velocity 100W Ballasts 100W 100W Face Tanner NA SolarMax IFT FT Ballasts NA 400W Cooling System 230cfm Turbo optiona 230cfm Turbo optional Timer System Digital Digital Max Exposure Time 20minutes 20minutes Back up Timer On board Watchdog On board Watchdog Remote Capability ze E T Max compatible T Max compatible CALL FOR SERVICE OR QUESTIONS 1 800 449 3605 6270 Corporate Drive Indianapolis IN 46278 2900 In Can
29. the large hole in one of the stand sb uprights as shown N v N 2 Slide a centering spring a clevis fork and then another centering spring onto the clevis pin and insert the pin the rest of the way through the upright CLEVIS PIN 3 Secure the clevis pin by inserting the straight portion of a bridge pin through the small hole in the end of the clevis pin 4 Repeat for the other stand upright Make sure the clevis forks point upwards as shown BRIDGE PIN CLEVIS FORK CENTERING SPRING E 2 Installation Assembly Procedures ma Stand Upright Assembly 1 Place the bench approximately where it will remain leaving room to work behind it 2 Make sure the clevis forks are pointed up and secure each stand upright to the rear of the bench pedestals using four 1 4 20 x 1 2 machine screws and four locknuts LOCKNUT others hidden STAND UPRIGHT N JN MACHINE SCREWS i V10 Z08SZ 25802 01A Canopy Installation Place two nylon floating bearings into each canopy arm Holding the canopy over the bench with the canopy arms inside the stand uprights insert clevis pins 5 16 x 2 1 32 through the uprights and nylon floating bearings to attach the canopy Secure the clevis pins by inserting the straight portion of a bridge pin through the small hole in the end of the clevis
30. the remote interface kit My bed is connected to the T The auto start feature of the remote system is disabled see the Max Manager remote system instructions provided with your remote system and when the delay time has expired the timer display starts counting down but the bed lights do not come on My bed won t work with the T 1 The sunbed must first be set to a unique address see Remote Max Manager remote system Connections 2 The bypass or terminator plug may be installed in the series in an inappropriate location Plug the bypass plug only into the bed at the end of the series Timer display continues to show a 1 T Max amp Manager remote system has not yet been set O after the timer button is pressed 12 Sunbed address is not set correctly see Remote Connections 24 ay Ly EDS Troubleshootin Problem My bed is connected to a T Max amp remote system but am having trouble getting into id mode My bed connected to a T Max amp Manager did not display dL but does indicate 0 a tanning time and the lamps have come on a tanning time but the lamps have not come on When auto addressing the first bed does not register an id When using a T Max 1A my sunbed won t function properly My salon suffers frequent short power outages and clients com plain about losing session time Solution You have probably attempted to connect your sunbed to the remote system already Disco
31. ton to count up or the body fan control button to count down until the desired number is achieved 1 99 5 Press the stop button to return to the normal display mode 14 Ja 200 AN A Installation Remote Connections Remote systems using a Control Relay Most non T Max remote systems control the sunbed by the use of a relay The relay oper ates the sunbed by connecting and discon necting a pair of wires leading from the sunbed Refer to the user s manual provided with your remote system to determine if it operates in this way To connect your sunbed to this type of system a remote interface kit is required Contact your place of purchase to obtain the kit Figure 3 details a typical con nection Follow the instructions provided with the kit and from the remote s manual to make the necessary connections CAUTION The remote connection is not designed to supply or accept high voltage nor can it provide power to an external timer The sunbed s remote inter face circuitry operates on 5 volts attempting to connect it to any higher voltages will damage the sunbed as well as void your warranty 15 Non T Max Remote System using control relay boo Remote Interface Kit figure 3 V10 20857 25802 01A we Po m N peration TR D Before You Tan Before using your sunbed please note the following important precautions
32. uit board The remote control bypass plug must not be used in this configu ration The 3A may be used as a master with no modification After you have set the T Max amp 1A s or 3A s address to 0 refer to your T Max user s guide and the sunbed s address to 1 see right simply connect the RJ 22 modular cables described in the T Max user s guide directly into either port located on the back of the sunbed and either port on the back of the T Max 1A or 3A See figure 2 figure 2 NOTE A T Max 1A with a master chip can be substituted for a 3A in figure 2 RUP E 1 8 SB Installation Remote Connections ANN ma Setting the sunbed address manually Before connecting your sunbed to the T Max amp Manager or T Max 1A or 3A the address of your sunbed must first be set Set the id man ually as described below Setting the id 1 Make sure no cables are plugged into your sunbed s remote ports 2 Remove and reapply power to the unit 3 Press and hold the stop button located on the sunbed display for three seconds and release The display should indicate an id number from oF to 252 39 100 199 1199 200252 IGE 4 If you are using a T Max amp 1A or 3A asa master remote the id of the sunbed must be set to 1 If you are using a T Max Manager each sunbed must be assigned a different id To set the id press the timer but