Home
MANU AL - Techgrow
Contents
1. SENSOR and the CO value will automatically be set to 9999 in order to keep the CO source deactivated 2 At night when the lights are off when the light sensor detects very little light or no light at all the CO source is ALWAYS deactivated That is why it is very important that the light sensor can directly see any light source Otherwise you would be unable to dose any CO during the day when the lights are on because the TechGrow T 1 controller would think it is night 3 The display backlight turns off automatically after 30 seconds Only when the button is pushed or turned will the display light up again TECHNICAL SPECIFICATIONS Power supply 110 or 230 Volt automatic Consumption 3 Watt with sensor without CO source Adjustment range CO set 300 to 2000 ppm Adjustment range CO 10to 200 ppm advice 50 ppm hysteresis bandwidth Measurement time 1 measurement per second Notes ore Ves want to feel safe Yes Want to sleep peacefu y Ves want to increase my growth CO Controller Min N u y F
2. WWW TECHGROW NL T CONTROLLER rl alco sensor light sensor and O calibration function gt z gt m TechGrow T 1 user manual CONGRATULATIONS You have purchased the TechGrow T 1 CO controller This controller is very easy to use and is by far the best in its class thanks to its fully digital technology and revolutionary Push amp Turn controls piola FEATURES Can be used in both small as well as very large rooms Plug amp Play e Adjustable from 300 to 2000 ppm e Extremely accurate external CO sensor manufactured by SenseAir Sweden the absolute market standard for CO measurements e The CO sensor has a built in light sensor that automatically switches between day and night settings e The sensor performs a new measurement every second e Turns the CO source CO generator CO cylinder on off via a 220V relay e Automatically detects whether the CO sensor is properly connected i e broken cable bad connection e Connection of the sensor via regular network cable UTP Comes equipped with 5 meters of cable The supplied cable can be replaced by a longer UTP cable maximum length 20 meters do not use repeaters e Modern blue and white display with automatic background lighting Display lighting turns off automatically after 30 seconds e Automatic 110V 230V detection e Power interruption memory for setpoint and hysteresis e LED indicator turns on when CO is dosed e B
3. djusted using the Push amp Turn Button PTB You enter the menu by briefly pushing the button An arrow appears on the left side of the display If you rotate the button now the arrow will alternately switch between CO set to CO and back again SETTING SETPOINT e Push the PTB once image 2 An arrow gt appears on the display of the value CO set e Push the PTB again image 3 A blinking square a appears in front of the CO value e You can set the desired CO level using the rotary button image 4 e Confirm this value by pushing the PTB or wait 5 seconds for automatic confirmation image 5 C02 ee COZ set DS net fond gt CUZ set LUZ 350 l a SOOD COZ 7 Min 8944 3959 Min 8949 gt C02 i Coz 0983 9 IAE A H0830 ae Se F c02 0058 Min 0949 Max 0960 Hin 0949 Max 8983 Lu wee PE lUZ set ee ee CO2 P Min 8949 Max 6966 TechGrow T 1 user manual ADJUSTING HYSTERESIS BANDWIDTH e Push the PTB once image 2 An arrow gt appears on the display next to CO set e Use the rotary button to move the arrow gt in front of CO image 3 e Push the PTB once for confirmation image 4 A blinking square a appears in front of the CO values e You can set the desired CO hysteresis by using the rotary button image 5 advised 0050 ppm e Confirm this value by pushing the PTB or wait a couple of seconds for automatic confirmation ima
4. ge 6 gt 9952 gt 02 set 5850 so Pees 02 0058 Max 0959 Min 0949 Max 0960 sae 2 MES meri EN zur sel u a i Y a k aa cel un was y Jo in Dais Aa ame er 0949 838 we l Min 0949 Max 0968 COZ 3983 0850 l T Cie set B a CU2 7 ooga PA oe COZ 2 Min 8949 Max 0963 Min 0949 ax 896 TechGrow T 1 user manual OPERATING THE TECHGROW T 1 CONTROLLER If the CO value of the room drops below the set value setpoint the CO source will be activated After a while the CO value will rise and when the CO set value has been reached the source will be deactivated again EXAMPLE The CO set is at 670 The CO is at 40 The current CO value in the room is for example 733 which is higher than the CO set so the CO source is deactivated The red light is turned off The CO gradually starts to drop to 670 still nothing happens Only when the value drops below the CO set minus the CO which in this case is 670 40 630 the CO source is activated and the light turns on The CO is now rising and as soon as the value of 670 has been reached the CO source is deactivated By adjusting the CO a quiet and stable atmosphere can be obtained The factory default for the CO set is 700 and the CO is set to 50 AUTOMATIC FUNCTIONS OF THE TECHGROW T 1 CONTROLLER 1 If no CO sensor is connected to the TechGrow T 1 controller the display will show NO CO
5. uilt in calibration function to adjust the CO sensor for outdoor Before using the calibration function please read the instructions carefully INSTALLATION 1 1 It is recommended to mount the CO sensor on a wall close to the CO source with a minimum distance of 50 cm It is not advisable to place the sensor directly over the CO source if that source can reach very high temperatures CO generator The sensor must be placed about 1 meter above the floor For this use the enclosed mounting bracket Sensor can Sensor left or right Fl CO source am ATTN please make sure the light sensor the milk colored cap on top of the CO sensor can absorb any light directly and is not obstructed by e g shelves or fixings as it will not be able to differentiate between night and day 2 Also mount the TechGrow T 1 controller on the wall with the enclosed bracket 3 Connect the sensor to the TechGrow T 1 controller with the supplied UTP cable 4 Plug the CO source into the socket of the TechGrow T 1 controller 5 Plug the TechGrow T 1 controller in to a 230V wall socket 6 Ready RESET MEMORY MIN MAX CO VALUES e If there is no arrow gt or blinking square a on the display please press the Push amp Turn button for 4 seconds Min max values will be replaced by the current CO level 7702 9952 A rE 0868 9058 Min 0949 Max 8968 OPERATING AND ADJUSTING THE TECHGROW T 1 CONTROLLER All the settings are a
Download Pdf Manuals
Related Search
Related Contents
Ryobi TS1143L Use and Care Manual Prioritization Tool User Manual - D&D KM-IT Samsung Galaxy S2 Plus Bruksanvisning mc-22 - MHM パワード・スピーカ 取扱説明書 ノートンのスポット溶接痕除去用 ノートンのスポット溶接痕除去用 取扱説明書 James Paquette 2005 KJ Powertrain Philips PowerPro Crevice nozzle CRP740 Copyright © All rights reserved.
Failed to retrieve file