Home

SCM Viewer User Manual

image

Contents

1. 497 MuFlo NuFlo SCM Viewer User Manual I NuFlo Measurement Systems A Nu o Feshnvtegi s Company Manual No 30165020 Rev A Revision History The following table shows the revision history for this document Description Approved by 2 6 2006 Initial release of SCM Viewer 2006 NuFlo Technologies Inc All information contained in this publication is confidential and proprietary property of NuFlo Technologies Inc Any reproduction or use of these instructions drawings or photographs without the express written permission of an officer of NuFlo Technologies Inc is forbidden Barton MVX ScanBase Scanner and ScanWin are registered trademarks of NuFlo Technologies Inc in the U S A and other countries Acrobat Reader is a registered trademark of Adobe Systems Incorporated Daniel is a registered trademark of Daniel Measurement amp Control Inc ISaGRAF is a registered trademark of C J International Annubar and Rosemount are registered trademarks of Rosemount Inc V Cone is a registered trademark of McCrometer Inc Windows is a registered trademark of Microsoft Corporation in the U S A and other countries All Rights Reserved Printed in the United States of America Manual No 30165020 Rev A February 2006 Table of Contents TABLE OF CONTENTS AS ga S 5 CHAPTER 1 INSTALLING SCM VIEWER quinto o pel atrae 7 IIA E ic EERE REA ATR o A pa Dao a SS Phe Hem ree Orient ame ttre
2. As above plus detailed tracking 80 As above plus extensive tracking 100 As above plus internal details 16 February 2006 Chapter 2 Using SCM Viewer 110 As above plus extensive details Window The Window menu allows the user to either select an open SCM file or automatically arrange the open files as shown below The Window options are available for selection only when an SCM file is open B SCM Viewer Node PL DEMO File PL DEMOO SCM Eh Elle Settings window Help we Beant F Cascade Tile Horizontally Poll Date 12 20 201 T Tile vertically erp E Minimize All Hourly History Da Sanne al Ttime w 1 Node PL DEMO File PL DEMOO SCM Help About Through the About selection a user can determine the version of SCM Viewer and view the end user license agreement to which he or she agreed when installing the application d File to NuFlo Manual Click on Manual to access an electronic copy of this document Send File to NuFlo Attention Scanner Software Product Team Leader Message Plain Text File Edit View Insert Format Tools Actions Help The Send File to NuFlo option is send did 0 0 A ie Aj Boz ou Sei es a shortcut for seeking technical sup p ort and 1S active only when bec iuFlo Helpdesk lt helpdesk nuflotech com gt a file is open When this menu Em S item IS selected the default e Subject attention Scanner S
3. To install into a different folder click Browse and select another folder You can choose not to install SCM Viewer by clicking Cancel to exit Setup Destination Folder CABARTONEDMS PROGRAM SCMVIEWER Browse Wise Installation Wizard Cancel 7 To install the program in a different location click on the Browse button The window shown at right will appear Navigate to the folder MEET in which you wish to install the files and lick OK If the directory an Cancel does not already exist you must create 1t before you perform this step E E backupdir O scanwin E semviewer E swlite 8 February 2006 Chapter 1 Installing SCM Viewer 8 The SCM Viewer installation program gives you the option of choosing a program manager group or creating sa ae ast your own program manager group Enter the name of the Program Manager group to add SCM Viewer icons to Click Next to continue NuFlo Measurement Systems Barton SCM Viewer Accessories Administrative Tools Barton Business Explorer Canon Printer Uninstaller Canvas 5 Dell El Wise Installation Wizard Cancel 9 The Start Installation dialog window will appear Click 2 SCM Viewer on the Next button to install SCM Viewer Start Installation You are now ready to install SCM Viewer Click the Next button to begin the installation or the Back button to reenter the installation information Wise Installation Wizard Can
4. 14 2005 08 16 2005 08 18 graph dialog open and selecting a different i ils A cel Na Es s E Y Total Volume Y Total Ener Y Differential Pressure flowr un tab fr om the Main SCT een gt Flow Extension Flowing pee Live Temperature vV Real Gas Relative density V Volumetric Heating value V Meter factor Y Flowtime The parameter represented by the y axis scale on the left is determined by the Right cick sole te Bric Bem ficos selection in the Scale to use dropdown menu above the graph The user selects the types of data to be displayed in the graph by checking or unchecking the checkboxes in the legend below the graph The range of data viewed on the screen can be changed by specifying a Start date and an End date at the top of the screen or by using the zoom buttons Regardless of the view displayed the Reset button at the top of the screen will restore the default range view Export from Graph Window The Export button at the bottom of the screen allows the user to copy save or email the graph in a variety of formats To export Picture the graph click Export select the format desired select a color Options size setting and press the appropriate button Copy Save or Send Colors Default od at the bottom of the dialog screen Click Close to return to the E Monochrome Graph screen Print from Gra
5. 5CM AO IAS e Number of records within the file Places CNES File name fi 131DE07 SCM Files of type Scanwin SCM files v Cancel e The date and time the data was downloaded from a Scanner e The name of the node related to the data collected e Data A summary of data types contained in the file and the number of flowruns or dataloggers represented An S indicates data that is specific to the entire system e Range The beginning and ending date time of all data collections within the file Not all data will have the same beginning and ending date time but all data will fall on the beginning or ending date or somewhere in between To open the file push the Open button The screen shown on page 13 will appear See Chapter 3 for a detailed explanation of parameters displayed To close the dialog without opening a file click the Cancel button 12 February 2006 SCM Viewer Node PL_DEMO File PL_D Fie Settings Window Help Poll Date 2005 12 20 11 26 23 Configuration gt Events Status Flags 2005 08 24 22 00 00 005 05 24 23 00 00 005 05 25 00 00 00 005 05 25 01 00 00 2005 08 25 02 00 00 2005 08 25 03 00 00 2005 08 25 04 00 00 2005 08 25 05 00 00 2005 08 25 06 00 00 Gia 46 5 5 5 40 6 na a RR Status Flag Current selected date time p partial H H out of range e estimate E flowrun alarma bl memory Faulk check alarm E events occured status 1
6. File 1131DE07 SCM Version SCM 1 2 No of flowruns 3 No of records 23 Date collected 2005 09 13 13 05 38 Node 1131DEM3 Data Cfg 5123 Hist 123 Evts S UCs 5123 DLs 1 Range 2005 09 12 15 47 11 to 2005 09 13 13 04 35 13 SCM Viewer Close Pressing the Close button will close the active open SCM file Recent Files List The Recent Files List contains the four most recently opened SCM files Any of these files can be opened simply by clicking on it Exit Pressing the Exit button will close the application Settings l SCM Viewer The Settings menu options Options Unit Type and Logging Level allow the user to change settings Ele Settings Window Help affecting the application Changes will not affect Options currently open SCM files but will apply to any files Unit Type opened after the settings are changed d Logging Level gt Options The Options menu is the general dialog that specifies how data will be represented within the application Changes made to this dialog become effective only after the OK button is pressed To exit the dialog without making changes press Cancel History Tab The History tab allows the user to specify how specific data will be displayed within the application The settings are categorized under four main groupings General Spreadsheet Graph and Graph Settings The user can change the following data as shown in
7. Input Default mode 0x081B0801 Old Value On New Value Auto Change Number 845 Change Type ScanWin DatalD value change with category Change Occurred on September 16 2005 13 27 26 logged in Manager via network Resource 127 RTD Input Input mode 0x081B0601 Old Value DIN Shift New Value Calibrated System 4 RUNOO1 1 4 RUNOO2 2 y RUNDOS 3 Export All Print All Tabs ENTER Y C Print Current Tab Ey Print A February 2006 Export All Export Clicking on the Export All button at the bottom of the main SCM Viewer screen saves all events and user changes in a single file ordered by number Clicking on the Export buttons saves only user changes to the Chapter 3 Viewing an SCM File SCM file ordered by number The data is saved in a Word document format Print Clicking on the Print button at the bottom of the main SCM Viewer screen prints the data to a selected printer Radio buttons located immediately to the left of the Print button give the user the option of printing from only the selected flowrun Print Current Tab or all the flowruns included in the SCM file Print All Tabs ScanPLC If ScanPLC data exists in the SCM file a ScanPLC tab will be displayed The format for these events takes the information from a plc_evt fmt initialization file Buttons at the bottom of the screen allow the user to export data to generate a report in Word format or to print one or all ta
8. U user changes occurred status He Send to Mail Recipient The Send to Mail Recipient option allows a user to send an SCM file as an email attachment To send a file select the SCM file then choose File gt Send to Mail Recipient A message 1s composed in the default e mail program and the SCM file will appear as an attachment Simply enter the recipient s email address in the To field and press Send to transmit the file via email The Send to Mail Recipient option is active only when an SCM file is open February 2006 Firmware NFlo P43 2Fb2 Gr AHot default Y Hv default Chapter 2 Using SCM Viewer B HK EMOO SCM File C Barton bdmes DATAESPORTSSASCMSPL_ODE MOD SCM Meter Flowtime factor Live Temperat ure Flowing Pressure Flow Extension Differenti al Pressure Yolume kPa kPaa 19 161 06 023 19 161 206 023 13 161 206 023 19 161 06 023 19 161 706 023 19 161 206 023 19 161 206 023 19 161 206 023 Rir r r r r ir r r 19 161 206 023 Print Selection f All Tabs C Current Tab Print DE default SP default Temp default a Please review this file 1131DE07 SCM Node 1131DEM3 Message Plain Text File Edit Send dis Tools Actions Help ER ERA su View Insert Format Y Wy Subject Please review this file 1131DE07 5CM Node 1131DEM3 Attach E 1131DE07 5CM 29 KB Attachment Options A
9. datalogger depend upon the data contained within the SCM file Buttons at the bottom of the screen allow the user to view the data in a graph to export the data to a file or to print one or all tabs Right clicking in a cell within the table displays a dropdown list with similar options plus options to copy a Selection or an entire sheet to the clipboard for pasting in another application Graph To view data from the active datalogger as a graph click on the Graph button at the bottom of the main SCM Viewer screen The data shown is dependent upon the data within the spreadsheet and any user configurable options selected Since the graph appears in a window that is separate from the main SCM Viewer screen users can tab through graphs of associated dataloggers by keeping the graph dialog open and selecting a different datalogger tab from the Main screen The parameter represented by the y axis E scale on the left is determined by the Node KOCH File KOCHO0 SCM 2005 08 05 y 04 00 H Start Date 0 x Rese Q Zoom In QA Zoom Due 2005 08 18 y End Date Scale to use ANGGUN CESE 4 00 i gt 1 selection in the Scale to use dropdown menu above the graph Differential Pressure kPa 2005 08 06 00 00 Y Total Volume Y Flow Extension V Real Gas Relative density V Volumetric Heating value V Meter factor V Flowtime Right click scale t
10. provides all software as is THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY FITNESS OR OTHERWISE WHICH EXTEND BEYOND THOSE STATED IN THE IMMEDIATELY PRECEDING SENTENCE Seller s liability and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or materials is expressly limited to the replacement of such products software supplies or materials on their return to Seller or at Seller s option to the allowance to the customer of credit for the cost of such items In no event shall Seller be liable for special incidental indirect punitive or consequential damages Seller does not warrant in any way products software supplies and materials not manufactured by Seller and such will be sold only with the warranties that are given by the manufacturer thereof Seller will pass only through to its purchaser of such items the warranty granted to it by the manufacturer AY MuFlo Measurement Systems A NuFlo Technologies Company NuFlo Measurement Systems 14450 John F Kennedy Blvd Houston TX 77032 281 582 9500 www nuflotech com For technical support in North America 1 800 654 3760 nuflotechOnuflotech com Copyright 2006 NuFlo Technologies Inc All rights reserved Canada 877 891 6540 helpdesk nuflotech com Singapore 65 6737 0444 singapore nuflotech com Bognor Regis UK 44 1243 826741
11. uk nuflotech com
12. 0 29 16 00 00 2005 10 29 17 00 00 2005 10 29 18 00 00 2005 10 29 19 00 00 2005 10 29 20 00 00 2005 10 29 21 00 00 2005 10 29 22 00 00 2005 10 29 23 00 00 PTGY 4786368 PTGV 4786368 PTGV 4786751 PTGV 4785985 PTGV 4786751 PTGY 4785985 PTGY 4787698 PTGV 4785038 PTGV 4786751 4382095 4382095 4882486 4881705 4882486 4881705 4883451 4880739 4882486 2358313 2358313 2358502 2358125 2358502 2358125 2358969 2357658 2358502 PR PR PR RR RR nin RUNOO 1 y RUNOO2 2 Status Flag Current selected date time pe partial A Ai cto range e estimate Re fowror ales Me memory fault check alanis Ee Events occured estatus H l User changes occured Z statis H2 in the first column and the status flags for the associated date in the second column To view what status flags are associated with each date time click on a cell within that row Explanations of associated status flags are highlighted at the bottom of the screen Print Selection All Tabs Current Tab B Print DE default P SP default T Temp default G Gr RHof default W Hy default Ez Graph EB Export SCM Viewer Node PL DEMO File PL_DEMOO SCM El Ele settings Window Help asm Buttons at the bottom of the screen Poll Date 12 20 2005 11 26 23 AM allow the user to view the data in a graph to export the data to a file or to print one or all tabs Right clicking in a cell within the table displays a dropdown list with sim
13. Ponit ron GP E edia aiaa a al TUI AO UI ii i n 21 a 27 EXPO TEME O See een ani 27 PA ss capi ieee eos eee eens 27 E A A A A STEI ETN ETT 28 A A E A E E A 28 P EA AE AA A 28 A A ens 28 CHAPTER 4 TROUBLESHOOTING INFORMA TION 0 0000ccceesesocooooo000 ZO oa a e AMM 29 Problem Unaple to TE SCM VER ads 29 T iv February 2006 Introduction Introduction SCM Viewer is an offline viewer for SCM formatted binary files downloaded from Scanner Measurement RTUs The 32 bit SCM Viewer application supports viewing exporting and graphing of data contained within SCM files SCM Viewer is required for viewing data files downloaded with ScanWin Lite ScanWin PRO users have the option of viewing downloaded files within ScanWin or within SCM Viewer ScanWin Lite or PRO can be configured to automatically initiate SCM Viewer after a data download See the ScanWin Lite or ScanWin PRO manual for details SCM Viewer s easy to use interface offers a level of functionality that is equal to or greater than that available within ScanWin PRO About This Manual The SCM Viewer User Manual provides the information and procedures required to install uninstall and use SCM Viewer This manual is intended for field technicians and managers who have a basic understanding of Microsoft Windows Prior knowledge of SCM Viewer is not required February 2006 SCM Viewer 6 February 2006 Chapter 1 Installing SCM Viewer Chapt
14. UFCLPO0 AA E tie click Print in the graph window specify the printer choose file C Port setup options orientation margins etc and click Print in the E TeeChart Print Preview window Click Close to return to the ea i Graph screen e Reset Marans Cl OS e ee Margins More Normal The Close button at the bottom of the graph screen closes the graph dialog Bs Export from DataLogger Tab tx Saen O Data El MS HE Clicking on the Export button at the bottom of the a main SCM Viewer screen exports all the data from the dataloggers in a variety of file formats 5 including Excel comma delimited text HTML and Word document ii e My Documents My Recent Documents SE My Computer Excel File XLS Y Comma Delimited File CSY a ASCII File TXT E Internet File f HTM e gos EE Word Document DOC Save as type Excel File XLS Print from DataLoggers Tab Clicking on the Print button at the bottom of the RUNOO1 1 4 RUNOO2 2 4 RUNOOS 3 main SCM Viewer screen sends data to a selected Staus Flag Current selected datetime E partial AA cubo range D DR deranit 7 e printer Radio buttons located immediately above aes F fowum chamo P SP detal ria oe E E Maneno fault check alarmes emp default the Print button give the user the option of Lanta status 1 Ej RH deu EX Export E Print E User changes occured 2 statws HZ ve Ay default prin
15. ad is complete the loading progress bar will read 100 and the Main screen will open with the left tab displayed for viewing Only tabs that reflect data contained within the SCM file will be displayed Above the tab the following information is displayed e Poll Date the date time the data was collected from the Scanner Poll Data 2005 12 20 11 26 23 Time Status Flags Total Volume EBM3 kPa e 19 161 2005 08 25 06 00 00 PL DEMO 1 y PL 121 Look in E SCM 1 En Fe 4 1131DE00 SCM 2 1131DE15 SCM 1131DM06 5CM a 1131DE16 5CM 2 DEM1UNDO SCM My Recent a 1131DE17 SCM Documents a 1131DE18 5CM e a 1131DE19 5CM gt 1131DE20 5CM a 1131DE21 5CM Eanes 113108225CM e a 1131DE23 50M a 1131DM00 5CM a 1131DM01 SCM a 1131DM02 SCM a 1131DM03 SCM a 1131DM04 SCM a 1131DMOS SCM Desktop My Documents er My Computer a y My Network Places File name f1131DE07 SCM Scarwin SCM files y Files of type SCM Viewer Node PL DEMO File PL_DEMOO SCM Firmware NFla P43 2Fb2 Houi Hiiop Hourly History Daily History Configuration n Events ScanPLC Log Differential Flow Pressure a 2005 08 24 2200 00 2005 08 24 23 00 00 y 2005 08 25 00 00 00 2005 06 25 01 00 00 2005 08 25 02 00 00 2005 08 25 03 00 00 2005 08 25 04 00 00 2005 08 25 05 00 00 d d ddd ddd Sta
16. ayed the next time the application 1s run PL DEMO 8 4 PL 42 p partial H jul of range D DP default All Tabs Seine i r Hen ibs aia y SP default Ez Graph E Curent Tab nye dizam i AET i GRO defaut Bh boot TRT Flowing Live Extension Pressure Temperat ure d d ddd dddid U user changes occured 2 stalu 2 Y Ay defaut 20 February 2006 Chapter 3 Viewing an SCM File Hourly Daily History Tabs The Hourly History and Daily History tabs show historical data from the SCM file Sub tabs allow the user to select the flowrun to be viewed The sub tabs are labeled SCM Viewer Node 1131DEM3 File 1131DE23 SCM LA File Settings Window Help ice Bam Poll Date 2005 11 08 13 13 32 Hourly History Daily History Firmware NFlo M4 3 4Ra b File C barton bdms DATASEXPORTS 4SCM41131DE23 SCM Configuration Events User Changes Log Status Flags Total Yolume Total Energy fiocorerte Flowing Live mees Hawiy Pulse Pressure Temperature ctor Flowtime with the flowrun name and O a a ES number for example MCF MMBTU MCF psia 2005 10 29 13 00 00 PTGV 4785985 4881705 2358125 RUNOO l 1 2005 10 29 14 00 00 PTCV 4786368 4882095 2358313 The columns shown for each flowrun depend upon the data contained within the SCM file and the columns that the user has selected for display All spreadsheets show the date time 2005 10 29 15 00 00 2005 1
17. bs Right clicking offers the user the same options as the buttons plus the ability to copy a selection to the clipboard Export Clicking on the Export button at the B SCM Viewer Node EQT Plunger File EQT PI00 SCM ba File Settings Window Help ici Ban Poll Date 2005 11 15 09 12 16 Firmware NFlo P4 3 1F File C barton bdms DATASEXPORTS SCMSEQT PIOO SCM Hourly History Daily History Configuration Events V User Changes ScanPLC Log User Change Number 692 User Change Type ScanPLC program generated User Change Occurred on November 24 2004 19 16 57 User logged in None Record Type 150 Event Shutin Length 24 String 90 0 80 0 65 0 6 1 68 0 Casing psig 90 0 Tubing psig 80 0 Line psig 65 0 DP iwe Flow MCF d User Change Number 693 User Change Type ScanPLC program generated User Change Occurred on November 24 2004 19 16 59 User logged in None Record Type 150 Export Report bottom of the main SCM Viewer screen saves all data in a in comma delimited format Report Clicking on the Report button at the bottom of the main SCM Viewer screen saves all data in Word document format Print Clicking on the Print button at the bottom of the main SCM Viewer screen prints all data to a selected printer February 2006 25 SCM Viewer DataLoggers Tab Data logs can be used to log variables that are not included in the flowrun hourly log
18. cel 10 When the installation is completed the dialog window at right appears and a shortcut icon will appear on the SCM Viewer has been successfull installed desktop of your computer Click Finish Click the Finish button to exit this installation Dance Uninstalling SCM Viewer To uninstall SCM Viewer select the application within the Control Panel gt Add Remove Program menu or optionally run the file Unwise exe within the install directory C BARTON BDMS PROGRAM SCMVIEWER Only application files will be deleted when the application is uninstalled all data files and directories will remain on your hard drive February 2006 SCM Viewer 10 February 2006 Chapter 2 Using SCM Viewer Chapter 2 Using SCM Viewer About SCM Files An SCM file can contain up to five different types of data e Configuration data of selected flowruns and or system S data e Historical data daily and hourly of selected flowruns e Event data of selected flowruns noted and or system S data e User change data of selected flowruns and or system S data e Data logger data of selected data loggers By default SCM files are saved to the following directory c Barton BDMS Data Reports This destination directory is user configurable however See the ScanWin PRO or ScanWin Lite manual for information on customizing the destination directory Opening SCM Viewer To open SCM Viewer click on the short
19. changes in a single file ordered by number Clicking on the Export buttons saves only events to the SCM file ordered by number The data is saved in a Word document format Print Clicking on the Print button at the bottom of the main SCM Viewer screen prints the data to a selected printer Radio buttons located immediately to the left of the Print button give the user the option of printing from only the selected flowrun Print Current Tab or all the flowruns included in the SCM file Print All Tabs User Changes The User Changes tab shows the user changes data from the SCM file Sub tabs allow the user to select the flowrun to be viewed and a System sub tab shows user change data specific to the Scanner as a whole Buttons at the bottom of the screen allow the user to export data to a file or to print one or all tabs Right clicking offers the user the same options as the buttons plus the ability to copy a selection to the clipboard 24 B SCM Viewer Node 1131DEM3 File 1131DE23 SCM t File Settings Window Help BEM Poll Date 2005 11 08 13 13 32 Firmware NFlo M4 3 4Ra b File C barton bdms DATASEXPORTS SCM4 1131DE23 SCM Hourly History Daily History Configuration Events User Changes Log User Change Number 544 User Change Type ScanWin DataID value change with category User Change Occurred on September 16 2005 13 27 01 User logged in Manager via network Resource 1427 RTD
20. cured status H Oense changes occurred 2 status H2 Tab or all the flowruns included in the SCM file All Tabs Configuration Tab The Configuration tab shows the configuration data from the SCM file Sub tabs allow the user to select the flowrun to be viewed and a System sub tab shows configuration data specific to the Scanner as a whole Buttons at the bottom of the screen allow the user to export the data to a file or to print one or all tabs Right clicking in a cell within the table displays a dropdown list with similar options plus options to copy a selection or an entire sheet to the clipboard for pasting in another application Export B SCH Viewer Node 1131DEM3 File 1131DE23 SCM EA File Settings Window Help PE Poll Date 2005 11 08 13 13 32 Firmware NFlo M4 3 4Radb Print Selection e All Tabs Current Tab Print DE DE default PSP default emp default 7 r R Gf default Ay default Export File C barton bdms DATASEXPORTS SSCM41131DE23 SCM Hourly History Y Daily History Configuration i Events User Changes Log Item Board ID Number Station number Gas Day Hour Number of flowruns Input battery voltage Battery charging voltage Low battery level Low battery deadband Low battery alarm status Low battery alarm output ATOD System Yoltage Reference NYRAM backup battery voltage RUNOOT 1 RUNOO2 2 ARUNOOS 3 Ex
21. cut icon on the desktop of your computer or click on the Start menu navigate to the SCM Viewer application NuFlo Measurement Systems gt Barton SCM Viewer gt SCM Viewer and click to open the application The Main Menu screen will appear The main menu has four headings File Settings Window and Help E Fille Settings Window Help File Menu The file menu consists of five menu options Open Send to Mail Recipient Close Recent Files and Exit SCM Viewer File Settings Window Help 1 i rc Tim 1 PL_DEMOO ScM 2 sWinl scm Exit February 2006 11 SCM Viewer Open Select File gt Open to view a list of SCM files Click on an SCM file to display a summary of file contents in the right column of the screen The SCM File contents can He contain the following Look in E SCM ES ej EJ SEM E EE information Fe 1131DE00 5CM 1131DE15 SCM 1131DM06 5CM File 1131DE0 SCH a 1131DE16 5CM_ 3 DEMIUNDO SCM Version SCM 1 2 My Recent l 3 1131DE17 SCM oi File name Documents 3 1131DE18 SCM Data solari 12 1131DE19 5CM 2005 09 13 13 05 38 8 1131DE20 5CM Desktop i 1131DE21 5CM Node 1131DEMS e SCM file format version EN a 11210E22 CM DS 2 1131DE23 50M ee l 12 1131DM00 5CM Number of flowruns within My Documents i 2 1131DMO1 SCM 1131DM02 SCM the file ar SCM a 1131DM03 5CM y 12 1131DM04 5CM 2005 09 12 15 47 11 A 5 m1310E14scm 5 11310M05
22. er 1 Installing SCM Viewer Installing SCM Viewer To install SCM Viewer perform the following steps 1 Open the ScanWin installation CD and click on SCMViewer_B100N_Setup exe 2 Follow the on screen instructions 3 The Welcome Screen will appear Close all Windows pro grams a then click the N ext button Pe e Welcome to SCM Viewer Setup program This program will install SCM Viewer on your computer It is strongly recommended that you exit all Windows programs gt before running this Setup Program Click Cancel to quit Setup and close any programs you have running Click Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Cancel 4 The License Agreement dialog is displayed Use the ZE SCM Viewer scroll bar to read the entire message Click the Yes button E aca if you agree to the terms of the agreement and wish to continue the installation purchased the right to use this software on one piece of hardware at a time This right is a license and not an ownership right Clicking the No button at this time or the Cancel button in pla ho saai a i ab gondii a later di alog S wall Cause the following S etup 1S not NuFlo Measurement Systems will no
23. hen the decimal places will be identical to Graph S ettinas Initial range shown on graph a a Days Background color on graph the decimal places used within the SCM file 2 Spreadsheet e Show This checkbox determines whether or not the data is shown on the spreadsheet If the checkbox is checked the data is shown on the spreadsheet if the checkbox is not checked the data will not be shown on the spreadsheet If the data is not shown on the spreadsheet it cannot be shown on the graph either e Column Width This value is the width this data takes up on the spreadsheet The column width can be changed on the fly by positioning the cursor on the right boundary of a column and dragging it to the right or left 3 Graph e Show This checkbox determines whether or not the data is shown on the graph If the checkbox is checked the data is shown on the graph if the checkbox is not checked the data will not be shown on the graph If the data is not shown on the spreadsheet it cannot be shown on the graph either e Color The color used to draw the line of data on a graph To change the color click on the color displayed and then select a new color Press OK to select the color Click Cancel to revert to the original color e Min Range Theminimum valueto beshown on the graph This number is ignored if Auto Min is selected e Auto Min Automatically determines the minimum value to allow the bottom most
24. ilar options plus options to copy a selection or an entire sheet to the clipboard for pasting in another application Feras Flo P4 3 2Fb2 Fie CABatoribdmsDATANEXPORTSASCMAPL_DEMOO SCM Hourly History Dady History Configuration Events ScanPLC Log E Time Status Flags Total Differenti Volume al Pressure Pp lee RE Ri Por h e H i a k i 4 H EL DeMo jan 4 PL 82 A Status Flag Curent selected date time Print Current Tab Print Selection EZ Graph E AlTabs C Curent Tab BR Eo Bem P 5P default ente occured G Gr RHof default U user changes occurred February 2006 21 SCM Viewer Graph B Node KOCH File KOCHOO SCM ij 0 x To view data from the active flowrun as a 2005 08 05 y id Reset 0 Zoomin O Zoom Out 2005 0818 y P Start Date End Date graph click on the Graph button at the oso lt Scale to use MEE 0400 bottom of the main SCM Viewer screen The data shown 1s dependent upon the data within the spreadsheet and any user configurable options selected Since the graph appears in a window that is separate from the main SCM Viewer screen users can tab through graphs of associated flowruns by keeping the Flowrun 9516116071 1 o b ho D Flowing Pressure 2005 08 10 09 00 5 872 93 kPaa D o T a mm a a 0 06 E E D E a o 2005 08 06 2005 08 08 2005 08 10 2005 08 12 2005 08
25. lows the user to search for specified text within the logged information Find what End Hest Match whole word only Direction Cancel Match case C Up amp Down 28 February 2006 Chapter 4 Troubleshooting Information Chapter 4 Troubleshooting Information Troubleshooting Information This chapter is dedicated to identifying common errors and problems encountered through normal use of this product This information is constantly being updated as new items are found if your problem is not listed contact the NuFlo Scanner HelpDesk at 1 877 805 7226 or 403 291 4814 Problem Unable to Install SCM Viewer Symptom The operating system should provide a message similar to the following Installation Aborted Internal Error Cause Attempting the installation on a NT 2000 XP machine as a user without administrator rights This error commonly occurs when the machine is part of a Novell network Solution Log into the computer as a user with Administrator rights and re run the install February 2006 29 SCM Viewer 30 February 2006 WARRANTY LIMITATION OF LIABILITY Seller warrants only title to the products software supplies and materials and that except as to software the same are free from defects in workmanship and materials for a period of one 1 year from the date of delivery Seller does not warranty that software is free from error or that software will run in an uninterrupted fashion Seller
26. o manually adjust values Flowrun 9516116071 1 2005 08 10 09 00 5 872 93 kPaa Flowing Pressure 2005 08 08 2005 08 10 2005 08 12 2005 08 14 2005 08 16 2005 08 18 00 00 00 00 00 00 00 00 00 00 00 00 Date Time V Total Energy Y Flowing Pressure Y Differential Pressure V Live Temperature EX Export E Print fl Close The user selects the types of data to be displayed in the graph by checking or unchecking the checkboxes in the legend below the graph The range of data viewed on the screen can be changed by specifying a Start date and an End date at the top of the screen or by using the zoom buttons Regardless of the view displayed the Reset button at the top of the screen will restore the default range view 26 February 2006 Chapter 3 Viewing an SCM File Export from Graph Window The Export button at the bottom of the screen allows the user to copy save or email the graph in a variety of formats To export the graph click Export select the format desired select a color setting and press the appropriate button Copy Save or Send Colors Default at the bottom of the dialog screen Click Close to return to the E Monochrome Graph screen Print from Graph Window The Print button at the bottom of the screen allows the user to RARE preview the graphical display before it is printed To print a graph LS rufopeTNN
27. oftware Product Team Leader mail program composes a Attach 1131DE07 5CM 29 KB ES 1131DEO7 log 4 KB Attachment Options message to to the NuFlo Product Version SCM Viewer B1 0 0Nb19 HelpDesk Attached to this Operating System Windows XP Build 2800 SP2 f gt Computer CPU Intel R Pentium R 4 CPU 2 80GHz message will be the SCM file Available Memory 509 98 MB Used 54 you have open as well as the log file that is associated with it Please enter the problems you have encountered with this SCM file To aid technical support staff in solving the problem add an explanation of the problem at the end of the message February 2006 17 SCM Viewer 18 February 2006 Chapter 3 Viewing an SCM File Chapter 3 Viewing an SCM File Opening an SCM File From the Main screen select File gt Open to view the SCM files available for viewing Click on an SCM file to display a summary of file contents in the right column of the screen Click the Open button to fully display the contents of the file The file contents 1s categorized by data type with each data type stored under a separate tab for example Hourly History Daily History Configuration etc When an SCM file is opened the data is read from the file and populated under the appropriate tab As the file loads the progress is shown on the log tab and entries are added to the log depending upon the log level When the file lo
28. ph Window IB preview of raph AA Printer Snufclgps01 NUFCLGPOO Setup Print e The Print button at the bottom of the screen allows the user to iento A E do S z A C Portrait preview the graphical display before it is printed To print a graph mec click Print in the graph window specify the printer choose file A setup options orientation margins etc and click Print in the mary Preview of Graph window Click Close to return to the Graph al screen ue JV View Margins F Detail More Normal lv Proportional Smooth Close The Close button at the bottom of the graph screen closes the graph dialog 22 February 2006 Export from Hourly Daily History Tab Chapter 3 Viewing an SCM File Clicking on the Export button at the bottom of the main SCM Viewer screen exports all the data from the flowruns in a variety of file formats including Excel comma delimited text HTML and Microsoft Word Print from Hourly Daily History Tab Clicking on the Print button at the bottom of the main SCM Viewer screen sends data to a selected printer Radio buttons located immediately above the Print button give the user the option of printing from only the selected flowrun Current RUNOOT 1 4 RUNOO2 2 4 RUNOOS 63 Status Flag Current selected date time pe partial HE Ai Gut of range Hovsrun alarme check alarms e estimate e memory fault C E events oc
29. port Yalue 00080866 1131 3 3 14 8331 28 8882 11 5 0 25 0 Unassigned 4 99729 Y 3 13725 Y Print All Tabs BS C Print Current Tab Ey Print A Clicking on the Export button at the bottom of the main SCM Viewer screen exports all the data from the flowruns in a variety of file formats including Excel comma delimited text HTML and Microsoft Word Print Clicking on the Print button at the bottom of the main SCM Viewer screen sends data to a selected printer Radio buttons located immediately above the Print button give the user the option of printing from only the selected flowrun Current Tab or all the flowruns included in the SCM file All Tabs February 2006 System ARUNOOT 1 ARUNDOZ 82 4 Print All Tabs BS C Print Current Tab ES Print 23 SCM Viewer Events The Events tab shows the events data from the SCM file Sub tabs allow the user to select the flowrun to be viewed and a System sub tab shows event data specific to the Scanner as a whole Buttons at the bottom of the screen allow the user to export data to a file or to print one or all tabs Right clicking in a cell within the table displays a dropdown list with similar options plus options to copy a selection or an entire sheet to the clipboard for pasting in another application Export All Export Clicking on the Export All button at the bottom of the main SCM Viewer screen saves all events and user
30. range data to be shown on the graph e Max Range The maximum value to be shown on the graph This number is ignored if Auto Max is selected e Auto Max Automatically determines the maximum value to allow the bottom most range data to be shown on the graph February 2006 15 SCM Viewer 4 Graph Settings The Graph Settings box near the bottom of the screen allows the user to establish the number of days of data that are visible at one timeon the graph and to specify the background color of the graph All data is loaded into the graph The range refers to how many days are visible in the default graph view The user can use the scroll bars to view additional data Units Tab The Unit tab allows the user to specify the ERES History Units unit to use with each item of data For historical data the user can select History Configuration Name Gas Liquid Category different units depending upon the type of Total Yoke Base m Temperaire E E otal Mass Lbm Yolume MCF flowrun gas liquid or monitor Units for Total Energy Distance n fi ti d t b d Uncorrected Pulse Total MCF Static Pressure kPaa con 1gufa 10N a a are ase upon Average Input frequency Hz Differential Pressure IWC categories and any changes here will A C meny m low Extension sqr ass Lbm affect all data within that categor
31. s or to log data at intervals other than hourly and daily Data logs are useful as trouble shooting tools The DataLoggers tab is very similar to the Hourly and Daily History tabs Sub tabs allow the user to select the datalogger to be viewed The sub tabs are labeled with the datalogger number for example DL 1 Clicking on a sub tab allows the user to view the associated historical data for that datalogger eaan SCM Viewer Node Ltest31 File VLtest01 5CM zy File Settings Window Help Poll Date 2005 11 23 09 23 08 Firmware NFlo M4 3 4RbC File CABARTONABDMSADATAE xports SCM VLtest01 SCM Time Hourly History Y Daily History Y Configuration Y Events Y User Changes DataLoggers Flowrun 1 Single Live Differential Pressure kPa Flowrun 1 Gauge Pressure kPag 2005 11 18 09 20 00 2005 11 18 09 25 00 2005 11 18 09 30 00 2005 11 18 09 35 00 2005 11 18 09 40 00 2005 11 18 09 45 00 2005 11 18 09 50 00 2005 11 18 09 55 00 2005 11 18 10 00 00 2005 11 18 10 05 00 o 2005 11 18 10 10 00 2005 11 18 10 15 00 snapshot 3102 600 3102 600 snapshot 3102 600 3102 600 3102 600 3102 600 3102 600 3102 600 3102 600 3102 600 3102 600 3102 600 Print All Tabs ts EA pri Ez Graph ER Export C Print Current Tab Print The columns shown for each
32. t be responsible for any consequential or indirect is damages arising from the use of the software whatsoever NuFlo does not provide a CO mplete mess age to be di spl ay ed warrant of merchantability or fitness for a particular purpose nor that the software will meet your particular requirements NuFlo Measurement Systems liability shall be limited to the value of the software regardless of the source of the liability Do you accept all the terms of the preceding license agreement IF so click on the Yes push button If you select No Setup will close Wise Installation Wizard You may continue the installation by clicking Resume or terminate the Install x installation by clicking Exit Setup gt Setup is not complete If you quit the setup bh y program now the program will not be installed ou may run the setup program at a later time to complete the installation To continue installing click Resume To quit the Setup program click Exit Setup February 2006 7 SCM Viewer 5 Choose your default unit of measurement SCM Viewer Options This unit can later be changed using the program s options settings Select unit of measurement to use re ane Imperial Wise Installation Wizard Cancel 6 By default the program files will be saved to your C BARTON BDMS PROGRAM SCMVIEWER If this AS location is acceptable click Next to continue Setup will install SCM Viewer in the following folder
33. the column headings of the screen capture on page 15 14 February 2006 Chapter 2 Using SCM Viewer Pale E B Options 1 General Name The name NuFlo applications use internally History Units General Spreadsheet Graph to describe the da ta User Text Decimal fShow O Show Color Min ato Total Volume Base 03060010 Total Volume a e ID The hex number Total Mass DED40010 Total Mass a r E Total Energy 11040010 Total Energy a NuFlo applications use Uncorrected Pulse Total 06020010 Uncorrected Pulse Total a internally for this data erage Input frequency O Differential Pressure 04020010 Ferential Pressure a o U ser T ext Th e name th e Hom pisco sqrt DP 02020010 pata 0 Flowing Pressure 01030010 Flowing Pressure a user Can set to describe Liwe Temperature 01020010 Live Temperature a Real Gas Relative density 07010010 Real Gas Relative density a the data Ad cd Fluid Density at flowing 06010010 Fluid Density at Flowing a Yolumetric Heating value 10010010 volumetric Heating value a s Decimal Places The Meter factor interpolated 04110010 Meter Factor a number of decimal places Base Solids and Water 2D010010 Base Solids and Water 0 Peak Pressure hourly 45010010 Peak Pressure di splayed in the values Peak Yolume Flow Rate 45030010 Peak Volume Flow Rate a shown within the application If the Decimal Places setting is set at 1 t
34. ting from only the selected datalogger Current Tab or all the dataloggers included in the SCM file All Tabs February 2006 27 SCM Viewer Log The Log tab shows the information that is logged as the file is loaded The amount of information depends upon the log level If the file could not be loaded successfully an explanation will appear within the log Right clicking the log data pulls up a menu that has the same options as the buttons on this page and the ability to copy any selected text to the clipboard to be pasted in another application Export B SCH Viewer Node 1131DEM3 File 1131DE23 SCHM La File Settings Window Help BED Poll Date 2005 11 08 13 13 32 Firmware NFlo M4 3 4Ra b File C barton bdms DATASEXPORTS SCM41131DE23 SCM Hourly History W Daily History Configuration Events ser Changes Log LeodngProgess 100 Message Summary Poll Time Messages Flowrun List Messages Flowrun Config Messages Event Messages User Change Messages Flowrun Parameter Messages Flowrun History Messages Convert Time 2 seconds EX Export Es Print 15 Find Do Clicking on the Export button at the bottom of the mam SCM Viewer screen exports the contents of the log into an HTML file Print Clicking on the Print button at the bottom of the mam SCM Viewer screen sends log data to a selected printer Find Clicking this button al
35. trees 9 CHAPTER 2 USING SCM VIEWER us nai nad edi cds tada A AMAIA 11 CI A it 11 aN T e i REEE EE VEE EE ETE OENE E EAA EIEE ISE EE VE A AEE EATE eee 11 ri 12 Be ee AM AAA E E cress 13 BLE A EE EE a 14 A AAA PA A 14 o A A 14 A 14 o A A A 14 o E Reece eee eee eT eee ye rene Terre r ome erre arnt re 14 E A AA AAA MMe nN AS ETO el nN A 16 E hac een nner eueRE Te ee eRe Ets PO TOPE ONC A eee eter TCT Tren 16 E AP Pi O A RR 16 o AAA 17 A eM A A Teme rT Neer eee er ere veer IOE I IE A nee er rete TEIA 17 IMA II AIEEE ENEN A A ren Teter 17 A ema eee A ee eae Tee A A ee NT eee nnT et Reenter ee mente a cree eer ree 17 O PAI IO PAPAA A EEOAE A A IAE ca 17 IA A O ria S 19 CAI AO WA aiii iria ii 20 ES RO A is ais iia acts Al Dq A 22 February 2006 T ill SCM Viewer Eont EtG VE iia de PA AO rt sai 22 A A A eee rT nee pH Export Trom Hourly Daily History DEDO A aca 23 ata li e a AAA A 23 AMOS TARA 23 AAA PA 23 Piola 23 A eee eee eee ew EAE AOE AOLE Taree nea ee neat me eT eve eee oe are rere 24 Jokes O ONE een ee meee Te eee a eee Ave EN Sere dd EEE 24 I ses th ee eg i ee a ee ee 24 o pesei EPE EEE AEE E O A des EEEE EEES E A rei 24 CO E PE epi eaaa ia 2 An 25 A A A A A A ame erent eat me ere 2 VESES site coche apse ns hvac A eee be ease eel dee eee 25 A A fee errr a PEAS metry ey 2 aa Seat ee URS RR RR AR RN RR AA 25 DO E sapos da di 26 CU cant A O PAE T AAT O E A ES PIPA AEE E A RO P PIA RARE NENE RREO RR DR 26
36. tus Flag Curent selected date time Print Selection p par H FAW out O gt DIP default e All Tabs SP default ES E Cent Tab Br RHoi default ER Export Ll gt usert changes occurred Hy default e Firmware the firmware version of the Scanner from which data was collected e File the file path of the file being viewed February 2006 ee Flowing Live Extension Pressure Temperat By Bint RIES SCM File Contents 1131DE0 SCM Version SCM 1 2 No of flowruns No of records 23 Date collected 2005 09 13 13 05 38 Node 1131DEM3 2005 09 12 15 47 11 to 2005 09 13 13 04 35 File CiBartonbdmrs DA TANEXPORTSASCMAPL_DEMOD S CM Meter Factor Flowtime i FF e e e e PPP a 19 SCM Viewer Changing Column Width SCM Viewer Node PL DEMO File PL_DEMOO SCM mee Hep RED Poll Date 2005 12 20 11 26 23 Firmware NFlo P43 2Fb2 File C BartonVbdie OA TAESPORT S45CM PL_DEMOOSCM Hourly History Daily History and Configuration data are presented in tabular format It may be necessary to adjust the default column width to properly view the data in table cells To change the width of a column position the cursor on the right border of the header cell in the column you want to change When the cursor aligns with the border and changes shape hold down the left mouse button and drag to widen the column These changes will be saved and will be a displ
37. y Flowing Pressure psia psia psia Density Lbm CF Live Temperature F F F Time Real Gas Relative density RDg RDg RDg Current T O change a unit simply select the cell Fluid Density at flowing Lbm CF LbmjCF Lbm CF voltage E Yolumetric Heating value BTU CF BTU CF BTU CF Absolute Yiscosity with the old unit to vlewa dropdown Meter factor Percent N2 menu Then choose a new unit from the eae emer o dropdown options If no dropdown menu Peak Yohmve Fem Rate sins Rate verte E Hourly Flowtime Yo Fo Yo Mass Rate Lbm appears units are not applicable for the rm EnergyRate MMBTUJA selected type of data or the unit cannot ae _ be changed from this screen and must be METE ta nar Static Setas edited manually within the related X Cancel scmviewer ini file Unit Type The Unit Type menu allows the user to select which unit format the application will use either metric or Imperial The default 1s set when the application 1s installed see Chapter 1 Installing SCM Viewer Log Level The Log Level menu sets the level of messages that will be written to the log file while loading an SCM file into the viewer The following list contains the common settings Level 20 is the default 1 Only error messages 10 As above plus warning messages and summary 20 As above plus basic conversion tracking 40 As above plus more conversion tracking 50 As above plus conversion processing details 60

Download Pdf Manuals

image

Related Search

Related Contents

OWNER`S MANUAL SINGLE CAT5E/6 3D EXTENDER  Manual de Instalación  Manual de Usuario – TWISTER 400 L  Journal Alès Agglo n°17 - Octobre 2014  Descarga el manual  manuale uso e manutenzione aeroevaporatori a  PDFファイル - 医薬品医療機器総合機構  Gigaset R410H PRO  Varian NMR Probes Installation  libretto istruzioni notice d`instructions instruction booklet  