1.   After the patient has removed their feet from  the turntable  manoeuvre the Secure Turn  away from the patient     
2. WELLAND    EDICA    drive       ORBITAL SEATER  USER MANUAL        PRODUCT CODE 800    NAME Orbital Seater       DESCRIPTION    High tensile steel revolving transfer platform  Two  revolving laser cut steel discs with a top frame bolted   to the discs and support handles welded to the top frame   2 x 100mm Dia rubber tyres allow manoeuvrability        TECHNICAL SPECIFICATIONS    Width between arms  17     43cm   Height of front handles from platform base  30     76cm   Height of top bar from platform base  39     99cm   Width  26     66cm   Depth  27     68 5cm   Disc diameter  18     45cm   Product weight  17kg  Recommended user weight  222kg  35st     USAGE REQUIREMENTS    1  Check castors are securely fitted before during and after use  This is important since  the lock nuts holding the two castors in place also secure the axle  tilt bar    2  The unit is designed to be used on LEVEL SURFACES only    3  Please ensure that the locking device is fully located before transferring a user from  one sitting position to another    4  Periodically check that the top frame is always fully secured to the revolving base  plate    5  Always ensure that the edges of the non slip surface  on top of the turning disc are  fully flush with the surface of the disc    6  Frames require an occasional wipe over with a soft cloth use general purpose neutral  detergent and warm water  Do not use harsh abrasive materials  To disinfect  clean  as above and wipe over with a solution of 1000 parts p
3. er million chlorine disinfectant   haztabs precept  rinse and dry     Do not attempt to move the unit from one position to another with a user  actually standing on it   INSTRUCTIONS FOR USE    INTENDED PURPOSE     The Secure Turn Patient Turner has been  designed to rotate a standing patient during a  transfer from e g  wheelchair to a chair     PRECAUTIONS     Ensure these instructions are fully read and  understood before use and please keep in a safe  place for future reference     Please note the patient must not be transported  using the device     Do not exceed the maximum user weight limit  of 30st  190Kg      Ensure the handle is facing the wheel and that  the brake is locked before manoeuvring  the Secure Turn     Never assist a patient to alight from the  wheeled side of the Secure Turn     Transfers should only be carried out to the left  or right through 45   or 90       Patient alighting should only be performed  when the brake is engaged and the Secure Turn  is stabilised by a carer     The Secure Turn should be inspected on a  regular basis for signs of damage or wear that  might affect safe use     Do not clean this device using an industrial  cleaner or high pressure hose as this may affect  the smooth operation of the turntable     CARE AND CLEANING    Wipe clean with a soft cloth  moistened with  disinfectant solution     INSTRUCTIONS     10     Familiarise yourself with the operation of the  Secure Turn before attempting to transfer a  patient  in particu
4. lar the brake locking  mechanism   To manoeuvre the Secure Turn into position   with the handle facing the wheels and brake  locked in position  tilt the device back onto  the wheels and move into position    Place the seat chair that the patient is  transferring to into position at 45   or 90   to  the patient s current position    Place the turntable up to the patient s feet  with the wheels facing the carer    The patient should position their feet  evenly  spaced  on the turntable mat  The patient may  need to move to the edge of the seat before  rising to reduce the effort required    When the patient needs to raise themselves  from a sitting position  e g  from below the  height of the handles of the secure turn  then  the carer must stabilize the unit by placing  their foot on the axle  midway between the 2  wheels  to prevent tilt  Alternatively  if the  patient needs to lower themselves onto the  secure turn e g  from a bed  then the carer  should stabilize the unit by placing one foot on  either of the lateral stabilizing lugs to prevent  tilt    With the Carer stabilising the Secure Turn  the  patient raises themselves into a standing  position    When the patient is standing and stable   holding on to one of the pairs of handles on  the frame   the carer releases the brake and  rotates the turntable to the required position  allowing the brake to lock into position    The carer stabilises the Secure Turn whilst the  patient lowers themselves onto the  seat chair  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Philips DLP2249/27 Data Sheet  Manuale  SUNNY HOME MANAGER in SUNNY PORTAL  P arceiros  Dominique Martin  Magit User Manual  l`environnement - Rivedoux  Autonics KRN50 Recorder Datasheet PDF  Measure Serial Control User Manual    Copyright © All rights reserved. 
   Failed to retrieve file