1. GROUP OF COMPANIES Wy DRUID Electric Fence Energizer USER MANUAL DRUID ENERGIZER ERVIcE SERVI NEMTEK Revision 1 1 www nemtek com 26 09 2006 DRUID USER MANUAL Table of Contents INTRODUCTION cines xnl du abo uec nda ati uu 3 COMPANY PROP IEE dota rhe Sae ELE este ees 3 GUARANTEE 4 STANDARD OPERATING PROCEDURES eee 5 STANDARD OPERATING PROCEDURES 6 STANDARD OPERATING PROCEDURES 5 7 5 amp 5 dios ideo tp ovt a ino Mt 8 9 Introduction amp Company Profile INTRODUCTION Thank you for choosing our product NEMTEK Electric Fence Energizers are designed and manufactured to provide many years of reliable use if installed and maintained correctly The guidelines provided in this manual will assist you with the basic operation and maintenance of your DRUID The DRUID is designed and manufactured in South Africa for the international market More information on our products and general information is available on our web site at http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry
2. Only if the alarm condition is resolved will the energizer operate without alarm activation Standard Operating Procedures Notes SERVICE INDICATION The service indicator should remain off during normal operation If it is lit due to an obvious condition such as prolonged mains failure simply turn the unit off and on again Should the condition persist refer to your installer FENCE INDICATION The fence lights indicates the condition of the fence in a bar graph type of display under normal conditions the graph will go all the way to the top and indicate that the fence is good If it does not reach the top the fence requires checking and clearing of vegetation If non of the lights come on there is a fault on the fence and the alarm will sound NOTES 1 The energizer will under normal conditions provide the fence with a pulse at the rated energy level Should a mains failure occur the energizer will automatically switch to a reduced energy level However should loading be detected on the fence the unit will revert to the rated energy level battery permitting until the load is removed or mains is restored This enables the unit to operate without mains for extended periods of time ie without loading and with good battery the unit should be able to operate for in excess of twenty hours Batteries should be checked on a bi annual basis 2 A functional energizer will only turn itself off with a prolonged mains failure or
3. if battery failure has occurred 3 There are no user serviceable parts within the energizer Please refer all problems to qualified service personnel 4 It is possible that under mains failure conditions the energizer will operate at reduced energy levels and the fence display will not be fully lit The mains should be restored first before checking the physical fence condition 5 Keep the fence clear of vegetation and do a periodical check for any slack fence strands etc Standard Operating Procedures LED s The status of the energizer and the fence is displayed on the front panel of the energizer as follows dh d o care Under normal operating conditions PASI Gi Power Mains present battery charging o Fence energized FENCE fence alarm cate No gate alarm service O No service condition If all flash fence is operating correctly Conditions that if ignored will sound the alarm POWER Restore mains see Note 1 on O Turn energizer on see Note 2 rence Q Alarm condition care Alarm condition Possible installer intervention required see Note 3 SERVICE Q Check later see Note 4 Concern see Note 4 Service fence see Note 4 Service fence Alarm Fence faulty 7 Q LED OFF Q LED PERMANENTLY LIT Q LED FLASHING Fault still present Fault occurred but is now gone Features amp Functi
4. is lit permanently the gate opening time exceeded the entry delay period but is now closed If the gate indication LED is flashing the gate is still open If the mains supply is present the power LED is lit and it will go out with a mains failure The On LED will be lit when the unit is switched on and it will be off when it is switched off The On LED will flash when the unit is switched to the Low Voltage mode ALARM INDICATION The fence and gate inputs are configured to trigger external alarms siren and strobe light and the internal buzzer Be aware that should there be a prolonged power failure the battery may run low and cause the service light to flash If the mains interruption is sufficiently long the unit will shut down and there will be no indication of mains failure RESETTING THE ALARM Switch the unit off with the Nemtek tab or remote key switch This will silence the siren if it has not already timed out internal buzzer and will switch the strobe off One of the alarm lights will be flashing or will remain lit to indicate the source of the alarm A permanently lit indicator notifies the user that the fault no longer exist In the latter case simply turning the energizer On again will clear the memory condition A flashing alarm light illustrates that the fault condition persist In this case rectify the condition which caused the alarm To reset and clear the memory condition turn the energizer On and Off and On again
5. rechargeable battery OPTIONS The energizer can be configured for different applications However there is only one external input so only one of the options can be selected The options should be discussed with the installer so that the energizer can be configured to suit the requirements Option 1 Gate delay entry of four minutes Option 2 Gate delay entry of one minute Option 3 Panic Alarm Option 4 Remote On Off Option 5 Remote On Off indication no alarm strobe light available and delay entry of four minutes Option 6 The energizer can be switched between High and Low Voltage mode
6. since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to international standards in order to ensure the highest quality products and continuous customer satisfaction Guarantee GUARANTEE The DRUID energizer manufactured by IO Tech Manufacturing Pty Ltd is guaranteed for a period of one year from date of sale against defects due to faulty workmanship or materials IO Tech Manufacturing Pty Ltd will at its discretion either repair or replace a product that proves to be defective IO Tech Manufacturing Pty Ltd guarantees that the product when properly installed and used in line with the specification as determined by IO Tech Manufacturing Pty Ltd from time to time will execute its function of generating a suitable potential IO Tech Manufacturing Pty Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free Faulty units must be returned to Nemtek Units 4 amp 5 64 Vervoer Street Kya Sand Randburg Gauteng South Africa OR Nemtek Security Warehouse Unit 4 Meadowdale Park Cnr Herman amp Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The
7. guarantee does NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are IO Tech Manufacturing Pty Ltd s sole liability and the buyer s sole and exclusive remedies for breach of guarantee IO Tech Manufacturing Pty Ltd shall not be liable for any special incidental consequential direct or indirect damages whether based on contact tort or any other legal theory The foregoing guarantee is in lieu of any and all other guarantees whether expressed implied or statutory including but not limited to warranties of merchantability and suitability for a particular purpose Standard Operating Procedure STANDARD OPERATION TURNING YOUR UNIT ON OFF In the default state the energizer can be turned on or off by holding the plastic tab over the corresponding logo on the fascia of the unit The unit will beep four times when turned on and three times when turned off STATUS INDICATION The unit will indicate that a condition is currently active fence fault gate open or service condition if the corresponding LED is flashing eg if the fence LED is flashing the fence voltage is currently not satisfactory If the fence alarm indication LED is lit continuously there was a fence alarm condition previously but the fence voltage is now satisfactory Similarly if the gate alarm indication LED
8. ons FEATURES amp FUNCTIONS INTEGRATED UNIT For energizers designed from a security perspective the fence monitoring is an integral part of the product The energizer is an integrated energizer battery charger and fence monitor with a siren and strobe light output LIGHTNING PROTECTION The mains and high voltage outputs are protected against lightning and power surges It also protects the unit against abnormally high potential differences between the high voltage and mains ground INTERFERENCE SUPPRESSION LOW EMI RADIATION The unit has been tested to comply with the latest international requirements CISPR14 2 1997 EARTH LOOP MONITORING For additional security the facility to use earth loop monitoring is provided for EXTENDED OPERATION DURING MAINS FAILURE The unit detects the mains failure and reduces the fence output energy However should the fence loading increase the unit will automatically provide additional energy to the fence within the limitations of the battery and energy rating of the unit SIREN OUTPUT 12VDC output for siren available STROBE LIGHT OUTPUT 12VDC output for strobe light available WEATHER PROOF HOUSING The unit enclosure is made of high quality weather resistant material Features amp Functions Cont d ARMED RESPONSE RADIO CONNECTABLE The system has the facility to be connected to an armed response radio BATTERY BACKUP The unit is supplied standard with a 12V 7AH
Download Pdf Manuals
Related Search
Related Contents
Ultrabook/Macbook用 トラベルドッキングステーション Pure Siesta DAB/FM Clock Radio 1328D-Manual-Fantec MR-35HDC_ Your guide to services and facilities 2012/13 Document N°1 78.6 ko - Conseil d`orientation des retraites 据付工事説明書 Cooper Lighting NEO-RAY Series 75 User's Manual König INK3-C9532CO ink cartridge Copyright © All rights reserved.