istruzioni oh/gsm inglese
Contents
1. Fig 4 OH A 01 OH RI MS pr sail LA f LAS ala 5 M1 nm f n OH MA OH GSM Dia l M1 Bus LA S Bus B2 S Ie OH T 01 M2 f pa A ol IS IS OH AS M4 2ov g M1 a flo l M2 LA Ng LAOUT K M3 BATT 1 2 BATT 2 OH B065 J OH BO65 J 230Vac N f the Hoasis home automation system contains an OH AS emergency power supply the output 20 V DC of the power supplier will simply have to be connected to the input of the OH GSM mod ule Fig 4 With this setup the OH B008 battery is not necessary as the runtime of the OH GSM module is guaranteed by the 0H B065 emergency batteries S Note The maximum connection distance from the OH A 01 or OH AS power supply on the BPT BUS must not be higher than 100m For BPT Bus electrical characteristics see single module instructions 12 bpt OH GSM connection to Bpt series TH programmable thermostats OH B008 OH GSM si CNI aay ma w osi 5 o amp Sd aoe SO STO 230V TRANSFORMER 230Vac Bpt TH 450 TH 350 TH 125 programmable thermostats can be connected to this contact or any other device remotely controlled thro
2. DELETION OF A TELEPHONE NUMBER IN THE ADDRESS BOOK If a telephone number in the address book needs to be deleted proceed as follows Example The message shown in the example allows to delete the number in position 5 of the address book leaving the same position in the address book empty the message has the following syntax M O D IN UM T E L 5 _ SPECIAL TELEPHONE NUMBERS IN THE ADDRESS BOOK It is possible to allow the messages from a specific telephone number to be sent to the first number in the address book This function can be used to allow the informational messages from the specific mobile telephone operator for example information on the credit to be sent to the first number in the address book o do this it is necessary to know the number for Service Center of the specific mobile telephone operator This number can be obtained by contacting Customer Service The programming message will have the following syntax P RIO GIN U M G E S number for telephone operator service centre n order to deactivate the function enter P RIO GIN U M G E ST 0 FIND OUT YOUR REMAINING SIM CREDIT n order to find out your remaining SIM credit a specifically structured SMS needs to be sent de pending on the specific telephone operator preceded by the word CREDIT Some operators for examp
3. seventh telephone number eighth telephone number ninth telephone number tenth telephone number Example he GSM dialler must send or receive messages to from only two numbers the address book programming message will have the follolwing structure P R O GIN U M T E L 1 3 9 3 4 7 1 2 3 4 5 6 7 1 3 9 3 3 3 3 4 5 6 7 8 9 A A Important The address book that is created via SMS will totally overwrite any pre existing address book ADD A TELEPHONE NUMBER TO THE ADDRESS BOOK a telephone number needs to be added to the address book proceed as follows Example the address book contains 5 numbers in order to add a sixth number send the following mes sage to the dialler M O D N UM T E L 6 3 9 3 3 3 8 8 8 8 8 8 8 This message overwrites a number in position 6 in the address book MODIFY A TELEPHONE NUMBER IN THE ADDRESS BOOK f a telephone number in the address book needs to be modified proceed as follows Example The message shown in the example allows to overwrite the number in position 2 of the address book with a new one that will have to be written after the text MODNUMTEL 2 MjO D N UM T E L 2 319 3 3 3 5 5 5 5 5 5 5
4. zona name q zona name zona name AUTO MANUAL OFF 20 8C HOASIS Network status ON System status request Stato impianto 4 lt Comment gt alarms OK zona MAN temp 20 5C Request for activation de ASA Check 12 24 5 lt Comment gt activation of SMS on system ON OFF 12 24 ON OFF Check 12 24 ON OFF status every 12 or 24 hours In SMS containing zona name or scenario name write the name of the thermal zone or scenario in exactly the same way as indicated in the programming software S Note In the event of a text message requesting the system status or heating zone status the controller will give a system or zone temperature between 10 0 C and 35 0 C even when the system or zone temperature is lower or higher than this interval For example if the temperature in the heating zone is 8 5 C the controller will respond with a zone temperature of 10 0 C 23 The device is equipped with a relay contact that can be used to activate TH Bpt thermal control systems designed for remote control TH 125 TH 350 TH 450 or any other device designed for the same purpose controlled through the opening or closing of a contact Reply SMS to the User Closing ofthe dialler auxiliary contact relay LJE JOIN RELE ON Function SMS sent by the User Opening of the dialler auxiliary contact relay LIE JO F F RELE OFF Closing of the dialler auxiliary contact relay for 3 seconds
5. 01 20 Through the dialler it is possible to manage up to 20 ther mal zones to do this associate the thermal zones created i through programming software to the specific boxes con aww LX cea val tained in the programming window of the GSM Module Fig 11 By simply clicking in the appropriate boxes it will be pos sible to choose one of the available Thermal Zones from a drop down menu Fig 11 TECHNICAL ALARMS Alarm 01 06 The GSM module can send a warning SMS in the event of an Technical Alarm this alarm must be programmed first through programming software as follows Display the system structure by pressing the menu Plant structure select the entry Security on the left hand side of the screen and click on the icon Alarms choose the icon of the alarm that E PCHoasis Smith House 215 xi File Utility Language For program guide press F1 Smith House Living E Living Room E Living components E Se A Gy Kitchen components E Network components NC Device not connected Id Idnot assigned Modiy Cancel Y ok DESIGN 16 07 2007 9 30 54 Fig 12 needs to be inserted from the list of alarms displayed on the right hand side of the screen drag it inside the de sired Space fig 12 and associate the created alarm to one of the inputs of the system Press Plant structure to return to the window di
6. If sononananana 106 rr TEC 45 70 64 5 Transformer on DIN 35 module 45 IL I Weight Dialler technical specifications 160 grams Container material PPOX Polypropylene oxide Degree of protection IP 30 Power supply 15V AC or from the 12 V DC supply line Standby consumption 310 mA with 15 VAC 110 mA with 12 V DC Communication consumption 360 mA with 15 VAC 180 mA with 12 V DC GSM module type Modem GSM GPRS Dual Band 900 1800 MHz Operating temperature from 0 C to 40 C Storage temperature 10 C to 60 C Relative Humidity lt 90 without condensation Transformer technical sp ecifications 230VA 15Vac Weight 340 grams Container material encapsulated in epoxy resin Degree of protection IP 00 Power supply 230 Vac 50Hz Secondar 15VAC 10VA 50 Hz bpt In order to operate the device must be equipped with a SIM card not included in the package to be inserted in the appropriate housing To do this unscrew the two fastening screws and remove the dialler cover Do this making sure that you do pull out the antenna wire SIM card not included SIM card housing A ATTENTION If the SIM card is new prior to inserting
7. OIN you wish to receive information on the system status every 24 hours the programming message will have the following syntax C H E C K 2 4 JOIN n order to deactivate this function the programming message will have the following syntax C H E C K 1 2 O F F or C H E C K 2 4 JO F F amp Note BPT declines all liability in case of transmission of SMS sent by the mobile telephone operator that decrease the remaining credit on the dialler SIM The User can take note of the main programmed parameters for his own benefit and as a written reminder in case of future work on the system 20 User instructions Commands performed by the User via SMS The Users whose numbers have been inserted in the address book can through SMS messages remotely control their Hoasis home automation system or request information on the status ofthe system INSERT A SCENARIO for example during programming through programming software a scenario identified as IGHT has been created in order to activate that scenario an SMS with the following syntax will have to be sent to the dialler S CTE NJA R 1 O N 1 G H T 23 Once the command has been performed the dialler will send a confirmation message to the user that has activated the scenario HOASIS NIGHT on CUSTOMISATION OF COMMAN
8. it into the dialler make a call by inserting it into a mobile phone thus allowing the mobile telephone operator to register the card The device requires that the SIM cards are activated only vocally and by SMS No SIM Data Before carrying out the programming operation deactivate the SIM card PIN code A ATTENTION The electronic cards can be seriously damaged by discharges of static electricity If they are to be handled wear suitable clothing and anti static footwear or at least ensure static electricity has been discharged by touching with the fingertip a metallic surface connected to the earth system e g the chassis of a household appliance bpt Assembly of the antenna On the shell of the module there is a seat for the insertion of the antenna included in the package If the module is installed inside a DIN box move the seat of the antenna into the appro priate additional hole on the shell thus allow ing its correct closure NL u_u s OD Module assembly on DIN rail The module can be wall mounted with or without terminal covers using the DIN rail pro vided as shown in figure 1 l Alternatevely it can be installed with or without terminal covers in metal containers equipped Fig 1 si with DIN rail EN 50022 A ATTENTION If the module is installed inside metal con tainers use the optional antenna OH ANT by placing it outside the container as
9. DS PERFORMED VIA SMS The SMS messages that are sent to the GSM module can be customised allowing them to be memorised and subsequently transmitted more easily or written in a different language from the default one Italian The customisation can be carried out using the SMS messages described in the coloumn high ighted in the table customised SMS sent by the User where in place of the word Comment a customised text can be added For instance in order to activate the scenario NIGHT previously created through programming software the following SMS can be used 1 lt I IWANNIT _ To A C T I V A T E T H E _ SIC EINJA R 1 O gt N I G H T that will receive the confirmation HOASIS NIGHT on Or in order to find out the status of the system the following SMS can be sent 4 lt W HIA T _ I S ITTH E SITTA T U S OIF TJH E _ S I SIT EM gt hat will receive the reply Hoasis Network status ON alarms OK zone AUTO temp 22 6C REQUEST INFORMATION ON THE STATUS OF THE SYSTEM n order to find out the general status of the system send an SMS with the following syntax SITIAIT O I M P I AIN T O A reply message will be received describin
10. EDIT In order to find out the remaining credit of your SIM it is necessary to send an SMS specifically struc tured depending on your telephone operator preceded by the word CREDIT Some operators for example Telecom Italia Mobile require a message consisting of text number the message will have the following syntax CIRIE D I T P RIE CIRIE ISTIIN 4 9 1 6 Other Operators Vodafone Italia for example require a simple number to be sent The message will have the following syntax CIR E D 1 T 1 C A L L 4 0 4 SD Note Through SMS messages it is possible to perform only one command for each message activate only one scenario change the status of the thermal zone The confirmation message depending on the telephone operator could take a few minutes BPT declines all liability in case of transmission of SMS by the mobile telephone operator that decrease the dialler remaining SIM credit Ifa message is sent by a number not present in the address book in order to activate one of the services the following reply will be received Telephone number does not correspond to user The messages sent and received by the GSM will be automatically deleted to prevent the SIM card memory from running out 25 ber Reminder of the Dialler settings Reminder of the numbers saved in the address book and their loc
11. ation Position Number User name Mobile Telephone Operator Service Center Reminder Thermal zone Reminder Scenarios I Ne Zone name Ne Scenario Name 27 BPT S p A Via Cornia 1 33079 Sesto al Reghena PN Italy info bpt it www bpt t CE
12. bet GSM Dialler OH GSM Installer and User manual bpt OH GSM telephone dialler is a device connected to the BPT bus line through a Hoasis home automation system which remotely allows only via SMS to Activate scenarios up to 16 Query and modify the status and temperature of the thermal zones up to 20 Be advised in the event of technical alarms in the home automation system up to 6 Be advised in case of damage outage and reset of home electrical power Carry out a system check every 12 24 hours The device is also equipped with a normally open relay contact which can be used to activate TH Bpt heat regulators designed for remote control or any other device set up for this purpose controlled through the opening or closing of a contact The device must be programmed through the programming software A Important The updated version of the programming software can be downloaded from the website www bpt it section Download gt Software The download password is OHSW2K7GSM Use and Applications Pag 2 Safety warnings Pag 4 Installer instructions User instructions General technical characteristics Pag 6 Commands performed Contents of package 6 by the User via SMS Pag 22 SIM Card assembly Pag 7 Insert a scenario recare 22 Comma
13. for activation of Bpt programmable thermostats RELE TH ON RELE ON RELE OFF Relay status request amp Note The RELE TH command sent to Bpt programmable thermostats activates a specific programme For more details refer to the programmable thermostats manuals SMS MESSAGES FROM OH GSM DIALLER The dialler sends informational messages on the control unit status to the numbers contained in the address book For instance in the event of a technical alarm the dialler sends a message indicating the type of technical alarm occurred followed by the date and time of the event Messages on technical alarms and network outage and reset will be sent to all numbers contained in the address book max 10 Informational SMS messages on control unit status sent by the dialler to the User Event SMS Message received Technical Alarm Technical alarm alarm name lt 25 05 07 gt lt 18 35 gt Electrical power outage Network Fault lt 28 05 07 gt lt 19 35 gt Electrical power reset Reset Network lt 28 05 07 gt lt 20 35 gt HOASIS Network status ON alarms OK zone AUTO temp 20 0C System status every 12 24 hours Furthermore the dialler if correctly programmed will also send all messages from the telephone operator service centre to the first valid number in the address book indicating the credit dead line 24 FIND OUT YOUR REMAINING SIM CR
14. g the status of the system for example HOASIS Network status ON alarms OK zone MAN temp 20 5C 22 Or it is possible to request information on the status of a specific Thermal zone previously created through programming software In the following example information is requested on a zone identified as living room SITTAIT O CTLTIIMIA TL I V I NJG _ R O O M A reply message will be received describing the status of the specific zone for example Climate living room AUTO 20 8C The following table shows a list of all possible messages that can be sent to the dialler in order to perform operations remotely or to receive information on the status of the system SMS sent customised SMS He epy ui by the User sent by the User APE Scenario 1 lt Comment gt HOASIS Scenario activation A x n 7 amp scenario name scenario name scenario name on Setting of thermal Clima zona name 2 lt Comment gt Climate zona name zone in AUTO mode AUTO Zona name AUTO AUTO 23 5C Setting of thermal zone in ae i i i Manual mode for example at Clima zona name 2 lt Comment gt Climate zona name MAN 20 zona name MAN 20 MANUAL 20 0C 20 C temperature Setting of thermal zone Clima zona name 2 lt Comment gt Climate zona name in OFF mode OFF zona name OFF OFF 23 2C Therra vonesatusraquast Stato clima 3 lt Comment gt Climate
15. he yellow LED switches off the operation was successful If on the con trary the yellow LED remains on this may indicate that there are GSM communication problems related to reception failure or SIM registration see chapter Montaggio della SIM Card Once the installation has been completed the yellow LED will flash only in case of data transmis sion reception on the GSM network S Note In Hoasis systems the red LED blinks OH GSM connection in a HOASIS system OH A 01 OHIRI 5 Ma fem LAS Tl ls olta 3 M1 a o l 4 OH MA OH B008 SS gt Il OH GSM CN1 dear E is Bus LA SI inant S F Buse Q fe M2 o OH T 01 T J IS O isv B a 280 V B TRANSFORMER 230Vac Fig 3 The OH GSM module is designed for connection to a 12V OH B008 battery that allows the tran smission and reception of SMS messages in the event of an electrical power outage Fig 3 With an OH B008 battery a runtime of a few hours in reception and the transmission of approxima tely ten messages is guaranteed A ATTENTION Connect the BPT home automation BUS to the terminals LA not to the terminals B2 bpt OH GSM connection in a HOASIS system with OH AS
16. is an adequate radio receiving signal from the device in the area where the device needs to be installed To do this simply insert the SIM in a mobile phone and check reception If reception is poor the device will have to be installed in another location with a better signal BPT S p A declines all liability in the event of failed transmission failed reception delayed transmission or delayed reception of SMS mes sages by the dialler when these are due to the quality of the reception signal or to any other problem related to the mobile telephone operator s activities charging cost on the dialler reamining SIM credit resulting from messages sent by the mobile telephone operator or from other services carried out by the mobile telephone operator Once the module has been placed in the appropriate containers as described in the previous pages proceed as follows Ensure voltage has been removed to the system Connect the terminal of the GSM module to the transformer Connect the dialler to the BPT HOASIS home automation system through the BUS LA terminal Connect the OH B008 auxiliary battery to the appropriate connector CN1 Connect the transformer to the electrical mains Now restore voltage to the system The lighting of the green LED indicates that the module is powered The yellow LED will remain on for a few seconds during which the GSM device will verify mobile reception If after a few seconds t
17. le Telecom Italia Mobile require a message consisting of text number in this case the message will have the following syntax CIRIE D I T P RIE CIRIE STI N 4 9 1 6 dpr Other operators for example Vodafone Italia require a simple number to be sent in this case the message will have the following syntax CIRIE D 1 T 1 C AIL L 4 0 4 DEACTIVATE SMS RECEPTION BY A NUMBER IN THE ADDRESS BOOK The default settings allow an event to be reported to all users through an SMS However it is pos sible to prevent some numbers from receiving these messages Example f you wish to prevent the fifth number in the address book from receiving SMS the programming message will have the following syntax P R O G S M S 5 O F F n order to reactivate SMS reception by the number the programming message will have the fol owing syntax P R O G S M S 5 ONN amp Note It is possible to deactivate SMS reception by a certain number only through programming via SMS ACTIVATE DEACTIVATE INFORMATION ON THE SYSTEM STATUS is possible to receive information on the system status on your mobile phone every 12 or 24 hours Example you wish to receive information on the system status every 12 hours the programming message will have the following syntax CIH E C K 1 2
18. nd customisation Positioning of the device Pag 8 that can be performed via SMS 22 Assembly of the antenna 8 Request information Module assembly on DIN rail 8 on the system status ee 22 Terminal boards and connectors Pag 9 le O nom I Qia en NA 2 Find out your remaining SIM credit 25 Commissioning Pag 10 Reminder of the Connection diagrams Pag 11 Dialler settings Pag 27 Programming of the dialler through programming software Pag 14 Activate deactivate System status information 5 Create an address book 5 Special telephone numbers in the address book 5 Thermal zones ici ita 6 Technical alarms 0 0 0 e cece eens 6 SCENANOS carino E 7 Programming of the dialler through SMS 8 Create an address book 8 Add a telephone number to the address book 9 Modify a telephone number in the address book 9 Delete a telephone number in the address book 9 Special telephone numbers in the address book sneen evnen 9 Find out your remaining SIM credit 9 Deactivate SMS reception by a number in the address book 20 Activate Deactivate information on the sy
19. ne numbers contained in the address book saved on the internal memory of the dialler itself S Note All the following settings can be programmed simply and intuitevely through the use of programming software by connecting the system to a PC through the OH SW interface without SMS A Important Before starting programming the address book via SMS make sure that the jumper SW2 LCK is connected With a disconnected jumper the programming of the address book can only be performed through programming software It is important to enter the appropriate international dialling code before the numbers that are being saved in the address book 39 for Italy The dialler when purchased can receive programming messages sent by any telephone number It is therefore advisable once the programming of the address book has been com pleted to disconnect the jumper SW2 CREATE AN ADDRESS BOOK The address book can be easily created via SMS messages structured in such a way that they carry the information necessary for programming the module The address book can contain up to10 telephone numbers Every programming SMS can send up to 5 numbers to the address book These SMS messages must have the following structure SMS n 1 P R O GIN U M T E L 1 first telephone number second telephone number third telephone number fourth telephone number _fifth telephone number SMS n 2 P R O GIN U M T E L 2 sixth telephone number
20. ns Network Select the GSM Module icon from the window con taining the module list and drag it to the desired switch board fig 7 At this point the identification code previously ac quired must be assigned to the module to do this se lect the module icon press Modify and associate ID to the module from the appropriate menu fig 8 w OH RP 0H 2RP modules E OHA module REI urent module BE oHm modue BS NH DiM modue E OHA module E 0H 401 mode Kitchen components ACTIVATE DEACTIVATE INFORMATION ON SYSTEM STATUS Check 12 24 In order to receive information on the system status every 12 or 24 hours on your mobile phone proceed as follows 391234567890 Click on the drop down menu Check 12 24 fig 9 and 392345678901 choose to activate the system check every 12 24 hours or select Off to deactivate this option then choose the day on which the check is to be performed and the time in which the message is to be received Fig 9 By selecting 12 or 24 the GSM module will send a de scriptive SMS on the system status to the first number in the address book every 12 or 24 hours for example HOASIS Network status ON alarms OK zone AUTO temp 20 0C 391234567890 392345678901 4 S Note z The information on the heat regulation refers to the first Gi rs STE one in the list of the dialler thermal zones Fig 10 CREATE AN ADDRESS BOOK Ph
21. one number 01 10 The following boxes are designed to contain the numbers maximum 10 of the users that will use the GSM module services By simply clicking in the appropriate boxes it will be possible to enter the telephone numbers that will make up the address book fig 10 A ATTENTION Always enter the appropriate international dialling code before the numbers that are being added to the address book 39 for Italy The telephone numbers can contain up to 19 digits In case of numbers containing more than19 digits and up to 24 it will be possible to programme the telephone numbers in the address book via SMS as described in the following chapters SPECIAL TELEPHONE NUMBERS IN THE ADDRESS BOOK Phone number 11 Messages sent by a specific telephone number can be sent to the first number in the address book To do this enter the number from which the messages are sent in box 11 of the address book This function can be used to allow the informational messages from the specific mobile telephone operator for example information on the low credit status to be sent to the first number in the ad dress book to do this it is necessary to know the number for Centro Servizi of the specific mobile telephone operator This number can be obtained by contacting Customer Service dpr For example Telecom Italia Mobile 393359609600 393359608000 393059609600 Vodafone Italia 393492000200 THERMAL ZONES Thermal zone
22. orrect operation of the unit and the system as a whole Do not install the device outdoors or in areas where it is exposed to seepage or splashes of water Handle the device with care It contains electronic parts that are fragile and sensitive to humidity The electronic cards can be seriously damaged by discharges of static electricity If they are to be handled wear suitable clothing and anti static footwear or at least ensure static electricity has been discharged by touching with the fingertip a metallic surface connected to the earth system e g the chassis of a household appliance Weld the joints between wires to prevent false alarms caused by oxidation of the wires The electrical system must comply with current standards in the country of installation Failure to comply with the above instructions may compromise the unit s safety The installer must make sure that the information for the user where applicable is present on the devices Dispose of the unit in accordance with current standards Installer instructions dpr General technical characteristics The OH GSM dialler is contained inside a DIN70 module and is powered by a DIN35 transformer The components can be attached to the spaces provided inside any electrical box equipped with DIN rail Contents of package GSM Module Transformer Instruction booklet DIN Rail Antenna Dialler on DIN 70 module TITITUTITONI NF
23. shown in figure 2 bpt Terminal boards and connections Connection for antenna N Optional auxiliary RS 232 connector to battery connector interface the module with a PC Green LED Voltage present i Yellow LED GSM transmission reception in progress Red LED On HOASIS systems the LED is always on SIM Card SIM Card housing Jumper SW1 TAMPER disabled Jumper SW2 address book protection Jumper SW4 boot loader BUS BUS C NO TAMP LA B2 Jumper SW3 default reset Terminal board for Bpt BUS Hoasis connection BUS B2 Terminal board for BUS B2 BRAHMS connection terminals not to be used in Hoasis systems Mi C NO Relay contact 12V 1A normally open TAMP Terminal board for TAMPER contact connection terminals not to be used in Hoasis systems M Terminal board for earth connection i VW Terminal board for connection to power supply from power supplier SW1 TMP When the jumper is connected the tamper contact is disconnected SW2 LCK When the jumper is disconnected the address book cannot be modified via SMS SW3 DFT By powering the module without jumper the default configuration is reset SW4 BTL Boot loader jumper reserved for the Technical Service not to be removed A ATTENTION Before installing the module it is important to verify that there
24. splay ing the system structure select the icon for the GSM module and access the module programming window A again by pressing Modify By clicking on one of the 6 ce sca A the Li the HET i alarms aww _ cea aa will now be displayed in the list and it will be possible to Fig 13 associate them to the available 6 alarm boxes fig 13 SCENARIOS Scene 01 16 It is possible to activate through the dialler up to 16 scenarios to do this associate the scenarios created through programming software to the appropriate box es contained in the GSM Module programming window By clicking on one of the 16 Scenarios boxes on the programming window choose one of the available sce narios from the drop down menu fig 14 E Modify M Cancel v ok Fig 14 SD Note It is highly recommended in order to make the use of the module easier for the User to follow the sequence of Thermal zone and Scene that have been inserted on OH T terminal BPT declines all liability in case of transmission of SMS from the mobile telephone operator that decrease the dialler remaining SIM credit The User can take note of the main programmed parameters for his own benefit and as a written reminder in case of future work on the system Programming of the dialler via SMS The OH GSM dialler allows remote control and signalling functions via the receipt and sending of SMS messages from and to the telepho
25. stem status eee cece 20 bpt A ATTENTION After removing the packaging check the condition of the unit The packaging items plastic bags expanded polystyrene etc must not be handled by children as they may be dangerous Carefully read the instructions before starting installation Perform work as specified by the manu facturer Before connecting the equipment make sure that the rating plate data corresponds to that of the distribution network An omnipolar switch with contacts separated by at least 3mm must be installed upstream on the equipment on the electric system of the building The manufacturer declines all liability for any damage as a result of improper incorrect or unreason able use Before performing any cleaning or maintenance operation disconnect the equipment from the power supply network by opening the system switch In case of failure and or malfunction of the device detach it from the power supply and do not tamper with it Use original spare parts Installation programming commissioning and maintenance of the product must only be per formed by qualified technicians who have been properly trained in compliance with current standards including compliance with accident prevention Operate in sufficiently lighted areas that are conducive to health and use tools utensils and equip ment that are in good working order Upon completion of installation always check for c
26. ugh the opening closing of a relay Fig 7 The device is equipped with terminals C NO of terminal board M1 a normally open relay con tact which can be used to activate TH Bpt thermal control systems designed for remote contro TH 125 TH 350 TH 450 or any other device designed for this purpose controlled through the opening and closing of a contact Function SMS sent Reply SMS by the User to the User Closing of the dialler auxiliary relay contact R E L E JOIN RELE ON Opening of the dialler auxiliary relay contact RIE L E JO F F RELE OFF Closing of the dialler auxiliary relay contact for three seconds for activation of Bpt programmable thermostats EILJE TH RELE THON RELE ON Relay status request SITIA T O _IR E L E REE OFF amp Note The RELE TH command sent to Bpt programmable thermostats activates a specific programme Refer to the programmable thermostats manuals for more details Programming of the dialler through programming software In order to programme the module create the system structure through the programming soft ware acquire the GSM module identification code and proceed as follows Display the system structure by pressing the Plant structure menu is Smith House fg 04 401 module 1 REG ORA node 1 FR orem FE Living Room In order to add the GSM dialler to the system press Connectio
Download Pdf Manuals
Related Search
Related Contents
3 - HOW TO CREATE A USER FOR THE FRONTDESK APPLICATION TP-LINK MA180 3G UMTS wireless network equipment BOLETIM OFICIAL - Banco de Portugal Service Manual – ALPGT Fresh-Trac 1 - Brother Operating Instructions Type 8835 Matrix Method and apparatus for modeling using a hardware Manual de Instruções Copyright © All rights reserved.