Home
HIGH POWER LED Pro Wash User Manual
Contents
1. 3 enter Don t 8 Signal signal button change Select DMX display iie Up enter Adjust the 9 brightness bright p brightness of button change z di the display isplay Press Adust the Display Flip enter Up enter display to be 10 Or Not DSPREI button change obverse or display reverse _ Set the time that the unit Press should keep 11 Dmx delay Dmxdl enter Up enter for the latest button change working display mode when there s no DMX signal YEAR M D Press Enter Set the Pro 12 Time time key for 2 3 Wash s inside H M seconds time WEEK Return to the 13 Factory FACT value that has Parameters just been setted Return to the Previous value that has 14 Parameters RREY been setted previously Red Test Pro G Wash s R GB ule CTC press Enter eee 15 Test test key for 2 3 p All seconds frequency Running shutt normal situation Dimer To display the Press temperature o f the light enter Up enter x 16 Temperature temper head via button change f display Centigrade or Fahrenheit P Set the ress running mode enter Up enter 17 Master as a master button change display unit or a slave unit Press Set the slave 18 Saver SlaviD enter Up enter No when button change working as a display slave unit Select whether it will Fress run as the way 19 Schedule Sched enter Up enter ot the tim Enable or not button change
2. HIGH POWER LED Pro Wash User Manual IRDW 7049126 00D 11 1 Introduction Thank you for purchasing IRDW 7049126 00D 11 high power LED washer This product is featured with LED It will provide you splendid vision enjoyment Configuration 49 PCS 3IN1 high power LED RGB module Angle x PAN adjustable 15 75 x TILT adjustable 50 50 x Optical Angle 25 2 Safety Information Read this manual before powering or installing the fixture Follow the safety information listed below and observe all warnings in this manual If you have any question about how to operate the fixture safely please contact the dealer or Neo Neon after service Always ground earth electrically And use only the power supply compliance with electrical code Replace the fuse and the bulbs with the same specified type Page 1 of 7 No spare parts are available If needed please contact the factory Do not operate if the ambient temperature exceed 40 C If any problem please contact the professionals or the technicians Under the circumstances that the mains power is not grounded earthed it is strongly recommended that the base housing should be grounded earthed in case of the potential damage caused by the electrostatic or electricity accumulation 3 Installation and Setting 3 1 Mounting Vile liN 3 2 PAN amp TILT Adjustment For PAN or TILT Movement adjustment please use the 6mm hex key TIL
3. 7 displ trigger event isplay that setted inside Page 4 of 7 Select the 20 Program Run Pgrun running programe Prog SCENE FIXT shutt dimer R G 2 Press Enter Set the units running 21 Program Set Pgset V mac key for 2 3 programe tmh seconds tm_m tm_s fd_h fd_m fd_s SCNRUN event program day Press Enter Set the time key for 2 3 trigger event start seconds gg 22 Schedule Schedl y end enable 1 Addr Setthe DMX s start and end channel 2 Balance Set the value of the balance white light Press Enter key for 2 3 seconds to go to the next menu Enabling selection ON or OFF 3 vr h G_h B_h Separately display the LED running time of R G B 4 _ bright Adjust the brightness of the display 5 Dspflip Adust the display to be obverse or reverse 6 Dmxdly Set the time that the unit should keep for the latest working mode when there s no DMX signal 7 Time Set the unit s inside time Press the Enter key for 2 3 seconds to go to the next menu Then it can set the Year month day hour minute week 8 FACT Return to the value that has just been setted 9 PREV Return to the value that has been s
4. Page 7 of 7
5. T and 3mm hex key PAN Page 2 of 7 4 Operation Instruction Panel On 4 LED Screen Enter UP DOWN 5 Function Introduction 5 editing available programes at most 10 modes per programe 36 editing available time trigger event It can be setted the start and the end time of the programe via per event 1 2 3 Temperature Sensor inside Ensure the temperature of the light head is below 60 degrees 5 1 Menu Introduction Main Main How is enter serial Display menu menu Submenu i Name Submenu into funtion number matter matter matter option submenu display change Press enter Up enter Set ale ea 1 Address A001 start and end button change f channel display Rblac Gblac Press Enter Set the R G B 2 Balance balanc N key for 2 3 of the balance Bblac seconds parameter Enable Press Default enter Default 3 Boost boost button OFF Boost off display Press 4 White Led RH enter Up enter Red LED Run Hour button change running time display Press 5 Green Led G H enter Up enter Green LED Run Hour button change running time display Press 6 Bule BH enter Up enter Blue LED Run Hour button change running time display Press enter Up enter R GB LED 7 L_H button change running time display Page 3 of 7 Press
6. etted previously 10 TEST Press the Enter key for 2 3 seconds to go to the next menu Then test the working state of the R G B LED of the unit 11 TEMPER To display the temperature of the light head via Centigrade or Fahrenheit 12 Master Set the running mode as a master unit or a slave unit 13 SLAVEID Set the slave No when working as a slave unit 14 SCHEDL Select whether it will run as the way of the time trigger event that setted inside 15 Pgrun Select the running programe 16 Pgset Press the Enter key for 2 3 seconds to go to the next menu Set the unit s running programe Each programe has the below setting Page 5 of 7 1 SCEN Select the mode 1 10 that you would like to set 2 FIXT When the unit runs as the master one it can set the slave No that the current mode includes The below selections are available all No odd No even No or any one of the slave units 3 shutter Set the strobe state of current mode Quick strobe strobe with quick lighting up and slow crushing out strobe with slow lighting up and quick crushing out random strobe etc Each state can be setted the speed 4 dimmer Set the brightness of current mode 5 R G B The brightness of each LED 6 mac Select the unit s effect of inside programe 7 tm_h tm_m tm_s The running time of current mode Hour Minute Second 8 fd_h fd_m fd_s The running FADE time of current mode Hour Minute Second 9 SCNRUN E
7. fading effect No waiting 48 55 high speed fading effect No waiting Page 6 of 7 56 63 very low speed fading effect No waiting 64 70 seven colors low speed changing chase 71 backup 72 79 seven colors middle speed changing chase 80 87 seven colors high speed changing chase 6 Maintenance and Cleansing 6 1 Troubleshooting Trouble Cause Shooting Check the mains power switch and the No power supply cabl s p Fixtures a not Disconnect the power and replace the fuse respond with the same specification If the fuse is Fuse burned burned again the problem should be cause by the circuit Please consult the technician Check whether the Resetting is normal but temperature of the Take the broken unit out and ask the special the menu no affecting surrounding or housing technician to maintain it has exceeded 80 degrees 6 2 Cleansing IRDW 7049126 00D 11 requires simple routine maintenance to secure its long life span and best performance 1 Maintain the cleaning of the fan and the air vents Dust should be removed from the fan and the vents periodically to secure the cooling and heat dissipation 2 Maintain the cleaning of the optical components 3 Check the wires such as the wire connection or the earthed wire periodically to secure the safety 7 Technical Specification Master Dimmer 0 100 Power 210W power input AC100 240V 60 50Hz Size L376mmXW232 mmXH432 mm Weight 13 5kg
8. nable this mode or not When the above setting is over please press Enter key for 2 3 seconds to save the setting and exit the menu 17 SCHEDU Set the time trigger event Press the Enter key for 2 3 seconds to go to the next menu for the setting There re below settings for each event 1 event Select the event that you would like to set 2 program Select the program that the event includes 3 day Set the day on which the event should run Monday to Sunday is available 4 start Set the time at which the event should start to run 5 end Set the time at which the event should stop 6 enable Enable the event or not DMX Function 1 Function Channel 0 3 All crush out 4 6 Manual Dimmer Mode 7 59 Changing Strobe 7 the fastest 59 the slowest 60 78 Fading Strobe 60 the fastest 78 the slowest 79 87 Random Strobe 79 the fastest 87 the slowest 89 255 Manual Dimmer Mode 2 Master Manual Dimmer Control 0 255 3 Red Manual Dimmer 0 255 4 Green Manual Dimmer 0 255 5 Bule Manual Dimmer 0 255 6 Color Temperature Adjusting 0 19 color termperature adjusting closed 20 255 From cold 2000 K to warm 2000 k 7 Function Channel Can control several connected units 0 7 backup 8 15 low speed fading effect Wait for 5 seconds 16 23 middle speed fading effect Wait for 5 seconds 24 31 high speed fading effect Wait for 5 seconds 32 39 low speed fading effect No waiting 40 47 middle speed
Download Pdf Manuals
Related Search
Related Contents
Jenn-Air Cooktop CCE9300 User's Manual TABLET PC - Ega Master 2. DESCRIPTION 3. INSTALLATION PACK COMBINE NC-6000 - Masterwork Automodules Tech Corp. S-7000 - Golmar VERSO Hi-PoE IPM Sony Headphones MDR-RF975RK User's Manual Sommaire Paragon Switch Operated Ceramic Kiln Instruction Copyright © All rights reserved.
Failed to retrieve file