Home
USER MANUAL FOR PUSH BUTTON PANEL ELS01DG WITH
Contents
1. so the user has to type for example 03 if he wishes to change the value of the third user code Page 2 Furthermore the value 00 is reserved to the master code and this code will never activate the output After the selection of the code the user has to introduce the old value after the introduction of the exact value a medium length beep is output now it is possible to enter the new code 5 digit long after the 5th digit a beep signals the code has been entered If the selected code was not already used a double beep and it is possible to intoduce immediately the value It is possible to clear a code simply selecting the value 00000 as the new code THE SYSTEM WILL NOT ACCEPT 00000 AS THE MASTER CODE B 3 END OF PROGRAMMING The end of the learning phase is obtained by pressing 0 and keys the keypad will go back to the working condition with all the codes updated NOTE In case of wrong selection it is possible to clear ALL the operation from the beginning of the last sequence pressing the key the system will come back to the condition of just entering the learning phase end of phase B Once entered the learning condition it is possible to perform several operations such as program ming many codes without exiting the learning phase but simply performing the required setting operations described above in sequence Sec B 1 and B 2 MASTER CODE CLEARING It
2. 21809 21809ke Speaker Amplifier 21323 230Vac 12Vac 22510B TO T P 6 OF HANDSET T1 BR O 4 ep j x J A iS oA YNVN N ooga 1 DC out max 500mA 3 Common in 4DCin 5 Battery RL1 RELAY 1 5A combination 4 5 and 6 RL2 RELAY 2 1A combination 1 2 and 3 combination 7 RL1 RL2 acet 5KPx1001 27 09 2005 N O normally open SW switch N C normally closed Page 1 acet around the world USER MANUAL FOR PUSH BUTTON PANEL ELSO1DG WITH SPEAKER AMPLIFIER 21323 AND KEYPAD 104602 Here are to be described installation and use of the digital keypads ACET mod 104602 The keypad is capable to store up to 1 7 codes the first code is the MASTER and it is used to enter the pro grammin mode while the remaining 7 are user codes _3 codes 01 02 03 for relay RL2 Max 1A _3 codes 04 05 06 for relay RL1 Max 5A _1 code 07 for both relay it is possible to activate only the required number of codes each code NEEDS to be 5 digit long Please note that _ 01 code has been setted as 01234 _ 04 code has been setted as 12345 _ 07 code has been setted as 11111 always is possible to change or unvalidate the codes following the below instruction The keypad is usually delivered with only onr code inserted i e the master code stated at 00123
3. The codes can be changed by the user with the following procedures The keypad includes a membrane 12 key keyboard a green LED indicator lamp a red LED indica tor lamp and a buzzer all these devices concurr during operation or programming operations the programming of the system is done from the keyboard with no need to move switches or jumpers so with no need to open the enclosure The green LED shows that the sistem is in stand by Each keypress is confirmed by a short beep sound while a missed code causes a long beep the LED lamp will indicate a correct code the LED will remain on for all the time the output relay is activated The codes are stored in a maintenence free non volatile memory with 10 years data retention no battery or backup supply is necessary Terminal description NO1 Normaly open for RL1 SW1 Switch for RL1 NC1 Normaly closed RL1 1 Out for DC low current 2 In for AC segnal 3 In for common segnal 4 In for DC segnal 5 In Out from to Battery NO2 Normaly open for RL2 SW2 Switch for RL2 NC2 Normaly closed for RL2 A INSTALLATION HINTS and REQUIREMENTS The maximum voltage appliable to the relay contact is 24 V a service pushbutton BS which will activate the output for all the time it is hold pressed can be connected to the connection header The connection diagram is shown on the last page it shows how to connect the optional backup battery and the clock PE that can be used to enable the servic
4. e pushbutton only within specified time slots the battery is charged from the keypad when the mains power is present B LEARNING MODE ENTERING The first operation requested to allow programming operation is to enter the learning phase instead of the working condition to obtain this the user has to introduce the master code stated in factory as 00123 after this operation the red LED will blink to confirm the instruction phase has been entered Now it is possible change either the codes or the length of the ON time of the output relay B 1 OUTPUT LENGTH SETTING It is possible to choose between several active output times depending on the kind of lock the selected time is choosen by pressing ONE key from 1 to 8 and followed by A to confirm the selec tion The times allowed are Key 1 gt 1 second Key 2 gt 2 seconds Key 3 gt 4 seconds Key 4 gt 8 seconds Key 5 gt 10 seconds Key 6 gt 15 seconds Key 7 gt 20 seconds Key 8 gt 25 seconds Key 9 gt 28 seconds The selected value is stored as soon as the key is pressed B 2 CODE SETTING The first operation requested is the selection of the code to be changed this is obtained by pressing TWO keys an confirming them with key this number can range from 00 to 07 please note that it is required a TWO digit number before the confirm key
5. is possible if needed to restore the master code to the default factory value the procedure is the following a Remove power supply either mains and or battery b Wait about 10 seconds to ensure proper power off c Hold down at both 0 and keys d Reconnect power while the previous keys are hold presed the LED will blink at a speed rate to confirm the proper execution of the operation e Remove power wait 10 seconds and reconnect it the keypad will work with the default master code Please be informed that this procedure will work ONLY when the system is powered on and this combination of 0 and keys will be considered as an error during normal operation all the tenant s codes are unaffected
Download Pdf Manuals
Related Search
Related Contents
TP820 User`s Manual (V1.4) Opérateur portail coulissant Apollo Nice Studio d´animation HUE A-107PS Importing AEMC Model 3950 Power Analyzer Data into your PC はじめにお読みください * O Livro Negro do Açúcar Aston SEN975-SS-48-10 Instructions / Assembly Bedienungsanleitung/User manual - guenther-tore Samsung S22A300H Benutzerhandbuch Copyright © All rights reserved.
Failed to retrieve file