Home
Cobalt Release Note
Contents
1. exist when using Cobalt software on these products e Channel count for Congo family hardware remains capped at 3 072 for Congo jr Light Server hardware and at 512 for Congo Kid consoles e Output count for Congo family hardware remains capped at 6 144 for Congo jr Light Server hardware and at 1 024 for Congo Kid consoles e New Cobalt masters modes are not available on Congo family hardware this includes Expanded Masters Expanded Effects and Expanded Sequences and Device mode e Multi touch functions are not supported on Congo Family hardware with XPe images e Avab IPX protocol is not supported in Cobalt software CAUTION Cobalt Software v7 0 0 and newer requires I O Board firmware versions 1 6 0 9 0 5 Congo and 1 3 0 9 0 5 Congo jr Congo Kid Congo Light Server to allow DMX and RDM to function properly on the local DMX ports The installation of this firmware is included in the Cobalt software installer Please follow the installation instructions within the installer to ensure that the firmware is installed properly Important Network Changes for Congo jr and Congo Kid as of v6 0 3 Congo jr consoles shipped after 9 August 2009 may encounter problems connecting to other Congo jr consoles using Gigabit Ethernet connections for example when connecting two Congo jr consoles in server backup or server client configurations To avoid this problem the installer for Congo v6 0 3 will set the connection speed to
2. amp TAB TAB double tap TAB to restore to default screen layout Independents Pressing a momentary independent switch and pressing GO will cause the independent to latch on Workaround Use a master and its flash key instead of the independent switch Thru on Effect channels can give strange results if you have renamed normal channels to internal effect numbers Channel Layout Using effect channels in a layout and changing the channel count will not update the effect playback numbers in the layout Workaround If the channel count is changed effect channels in layout may need to be updated REFRESH doesn t work when preset is manually loaded into A Upgrading Congo Jr to v6 0 from Image 5 0 1 OS v 8 0 will cause unexpected master wing behavior Workaround Image console from build 5 1 OS v 8 1 or later Install Congo v6 This did not produce any of the behavior described above Wings had normal functionality Goto List isn t refreshed when recording new presets in Build mode CobaltSettings window can become hidden beneath main Cobalt welcome screen Devices with assigned Scroller Rolls like a Revolution shows up as a scroller not a device in the channel views Client doesn t allow a Sr console to be used together with lon Jr modules Workaround Connect Sr and lon Jr modules to the Server A device whose IP address has changed may be shown with the old address in the Net3 ACN Device List Swap 0 zero and C Alt button does not work for text
3. 100MB Only Congo jr consoles may experience this problem and only when two consoles with the same motherboard are used Consoles with this particular motherboard can be identified easily they have two non operational DVI connectors on Cobalt v7 1 1 Release Note Page 6 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 the rear panel of the console Customers using these consoles will need to ensure that their network switch is capable of 100MB Ethernet connections If the switch is only capable of 10MB connections either the old switch should be replaced with a 100MB capable switch recommended or the console s can be downgraded to 10MB connection speed less recommended If a downgrade is desired please download the Intel NIC Config Repair Tool from the ETC Website Show File Compatibility Using pre Congo v6 0 showfiles on consoles running Cobalt 1 For MIDI output to be routable to either the local MIDI port or a network MIDI port the syntax for the MIDI Action Macro has been changed The port number has to be specified in the Action Macro after the MIDI keyword like this MIDI x data x is O for the local MIDI port similar to the serial port or gt 0 for Net3 GW ports 2 When using Channel Times channel delays in are now derived from the In time of the step instead of the In Delay It now works in the same way as Attribute delays Pre v6 x show files that use percent on channel
4. Information Key Enhancements in v7 1 1 e Bug fixes e Touch functions on the masters displays have been disabled and replaced with corresponding hard keys surrounding those displays e Additional translations of the help system Deutsch Francais Issues Corrected in v7 1 1 RND 0028579 Add Incandescent dimming curve for support of Desire S4 LED fixtures running v1 6 2 software RND 0028362 Decimal channels Changing channel count can cause additional channels to appear in the channel views RND 0028308 Multipart devices If channel downgrade is used devices with sub devices aren t saved correctly Can cause crash RND 0028280 Remove touch input from masters displays RND 0028279 Include the Latest Fixture Library RND 0028189 Attributes don t snap to the specified level when using the upper master encoder RND 0028160 Cobalt installer needs to include an executable to enable the second NIC on Cobalt 20s RND 0028142 Masters displays built in keyboard uses surrounding keys for input RND 0027557 Console Upgrade Utility doesn t work on ETCnomad Pucks in Cobalt mode or ETCnomad on PC RND 0027446 Changing monitor setup requires a user to go to open the Monitor Arrangement Tool and press Apply for Cobalt to recognize the change and give the user the ability to reconfigure it Cobalt v7 1 1 Release Note Page 3 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 Known Issues Remaining in v7 1 1 RND 002733
5. Version 7 1 1 and later software e Cobalt Offline Editor Version 7 1 1 and later software e Cobalt Offline Editor for Mac Version 7 1 1 and later software e Net3 Radio Focus Remote RFR Version 2 0 and later software e iRFR All versions e aRFR Version 1 0 2 and later e Net3 Gateway Configuration Editor GCE Version 1 2 1 and later e Concert Version 1 0 3 and later Additional Devices e Congo Radio Remote Focus Unit CRRFU Incompatibility Cobalt software is incompatible with hardware and software running ETCNet2 software prior to those listed above e ETCNet2 Video Node Any software version e TT Radio Remote Focus Unit Cobalt ETCnomad Mac and PC is incompatible with hardware and software running ETCNet2 protocol Cobalt software is incompatible with hardware and software running ETCNet1 Cobalt software does not support Avab IPX protocols on any hardware Congo family hardware included Cobalt v7 1 1 Release Note Page 2 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 Installation Instructions A CAUTION Owners of Congo family products Congo Congo jr Congo Kid consoles and Congo Light Servers running pre v6 0 0 software should read this important information Running Cobalt software on Congo Congo jr and Congo Kid consoles and Congo Light Servers on page 6 Step 1 Step 2 Step 3 Step 4 Step 5 Download the Cobalt Family Software install
6. delays need to be adjusted accordingly No automatic conversion can be made Updating to v7 1 1 from v4 x or v5 x Software WARNING IMPORTANT Congo jr consoles running v4 x or v5 x and the update to Cobalt software CHECK YOUR CONGO Jr Console HARD DISK IMAGE VERSION BEFORE PROCEEDING WITH THE UPDATE TO COBALT SOFTWARE Please read the full information directly below In some cases upgrading a Congo jr console to Cobalt software from version 4 x or 5 x of software may cause a connected Master Playback Wing to stop working If your console has OS_ Version r8 0 installed you will need to reimage your hard disk to get the wing working with Cobalt software Please note it is only this version of the image and the Congo jr console in combination with the Congo jr Master Playback Wing that is affected Congo consoles and Congo jr with Universal Wings 2x20 2x10 and 1x20 will work fine on the older OS version To verify which hard disk image is currently installed on your Congo jr console please go to the Welcome Screen gt System Settings or Exit to System Settings from the Browser The currently installed image version is shown at the bottom of the first tab in the format OS Version r If this displays OS Version r8 0 then you will need to re image your hard disk in order to update to Cobalt software Reimaging a hard disk will erase show files stored on that disk Before reimaging please back up show files you want to ke
7. minutes click Exit to close the I O updater dialog The installer will continue to run but you will need to update the I O firmware manually After completing the installation of Cobalt please go into the Systems Settings then click the UPDATE tab and use the I O Firmware Update utility to update the I O board Ensure that you choose the correct firmware file for the console you are updating When the firmware has been updated please restart your console to ensure proper output of DMX Step 9 Click the FINISH button at the end of the installation process The console will restart twice Step 10 Optional Download and run the Congo Movies installer using the installation instructions for consoles running v5 0 0 or newer to place the Congo Training Tutorials on your console See nstallation Instructions on page 3 Congo Facepanel Firmware Update Instructions A new version of Congo console not Congo jr or Congo Kid consoles facepanel firmware was made available with the Congo v6 0 4 release This version solves a rare master fader flicker problem and includes English German and French keyboards on the Master keys It is recommended that all Congo consoles not Congo jr or Congo Kid consoles be updated with this firmware as soon as production schedules allow Required Files Before starting the firmware update procedure make sure the following files are located on a USB memory stick Firmware_Downloader exe This applicat
8. 0 RND 0025959 RND 0025948 RND 0025429 RND 0020606 RND 0019283 RND 0015525 RND 0012083 RND 0010809 RND 0010622 RND 0010381 RND 0010352 RND 0010340 RND 0010312 RND 0010222 RND 0010221 RND 0002019 RND 0002017 RND 0002013 RND 0002012 RND 0002007 RND 0002001 RND 0001992 RND 0001990 RND 0001983 RND 0001977 RND 0001974 RND 0001972 RND 0001971 RND 0001970 RND 0001965 RND 0001930 RND 0001928 Cobalt v7 1 1 Release Note OSC Could crash on exit if specified OSC address doesn t exist Cobalt Settings should display the full six digit version number for firmware Cobalt Offline for Mac Cobalt Settings will not store properly on Macs where Eos Offline was installed previously Workaround If you encounter this problem please see our support article containing the steps to fix this on your Mac http Awww etcconnect com Support Articles Cobalt Offline for Mac Installed after Eos Offline for Mac aspx Import Organizer Importing For Each Device type palettes doesn t set dependencies Importing palettes that are referencing a specific template isn t recommended Mac Qt4 8 TAB doesn t work to step through tabs after dragging and dropping tabs between the screen Possibly after having an empty screen with no tabs Drag and Drop tabs to empty screens is not supported If the system gets into a state were all tabs and docks are closed it appears you can not get out of that state easily Workaround PRESS C ALT
9. ETC Release Note Cobalt Lighting Control System Software Product Line Cobalt Lighting Control System Description Version 7 1 1 software Engineering Change Master ECM 500012952 Effective Date 2014 10 10 Purpose This version includes bug fixes and new translations of the help system Due to customer feedback we are also disabling the touch function of the masters displays in this version supporting all of those functions on the corresponding master keys surrounding those displays All users are recommended to update to this release as production schedules allow For any questions relating to the contents of this release or the behavior of this software please contact ETC Technical Services at the office nearest you A list of ETC offices is given at the bottom of this page Availability You may obtain this release of software by downloading it from the Downloads section of the ETC Web site www etcconnect com Once downloaded the installer must be placed on a USB flash drive with enough space approximately 210 MB Documentation The current documentation is the Cobalt v7 1 User Manual The online help system within the Cobalt family software has been updated with new content for the v7 1 1 release Items are followed by 7 1 1 in the table of contents ETC manuals can be downloaded free of charge from ETC s website at www etcconnect com They are available in portable document format pdf and viewable with the free A
10. b Workaround Move tab from one screen to the other to refresh contents Highlight on a client does not highlight the output Page Up Page Down does not work in List editors Independent Keys enabled via console mimic on Client are not matched on Server DMX In universe cannot be mapped to the same universe number for output Workaround Map incoming levels to a different universe Congo will not enter channels only mode if activated before starting the application Patching outside of a console s Universe space gives unclear warning Parked List Delete jumps to the beginning of the list Layout Editor Wizard objects list shows content that do no work in Wizard REC amp PRESET with empty Seq in MainPB activates Record All Attributes flag Direct Selects do not update PARAM data type correctly when the param depends on range tables for data Using Master Key Wheel to raise lower masters also sets Pause Play flag on Chase Sequences Workaround Use START command to raise master playback without changing pause play status In some situations client consoles refresh slowly when used as clients Workaround This can be highly dependent upon the specific network configuration of the site Please contact ETC Technical Services With Channels Only mode active at startup Congo jr starts in Ch Only but displays as if in Masters Mode Workaround Start in Masters Mode and then switch to Channels Only Pressing an independent switch with another independent switc
11. cation A CAUTION This application has to be started within 30 seconds after the completion of the above step In the upload application a status line will be visible e Wait until the USB connection is established This might take up to 30 seconds e After successful connection the file button will be enabled e select the correct version of the src file and press the download button After successful completion of the download process restart the console to resume normal operation A CAUTION Do not turn off power to the console during the firmware operation If power is lost in the middle of firmware upload it is usually possible to re start the upload from step 4 again If this is not possible for some reason the board has to be sent back to ETC for service If the firmware upload is initiated by accident simply wait for a couple of minutes The old firmware will still be present if the actual download process hasn t been started Restart the Console Hold CTRL ALT DEL on the external or built in keyboard Click the Shutdown button in the dialog and select Shutdown or Restart Then confirm the dialog to restart Congo Cobalt v7 1 1 Release Note Page 10 of 10 Electronic Theatre Controls Inc
12. cluded with the Congo v5 0 0 Image If an older console is updated and Net3 Services are required please download the installer from the ETC Web site directions for finding the installer are given below and run the installer on your Congo console Net3 Services is installed as part of ETC Net3 Gateway Configuration Editor GCE To download this go to www etcconnect com downloads aspx type GCE into the Keyword field select Download Type Software then click Search All available versions of Net3 Gateway Configuration Editor GCE software will be listed below Select the latest version from the available list Download and install this using the installation instructions for Congo v5 0 0 or newer to add Net3 Services to your console See nstallation Instructions on page 3 for more information Installation Instructions from v4 x Software See nstallation Instructions on page 3 for installation instructions from v 5x or newer Congo Congo jr Console amp Congo Light Server and Net3 RVI running v4 3 4 soft ware or older Step 1 Download the Cobalt Family installer file from the Services section of www etcconnect com Step 2 Unzip the software find the Cobalt Family installer file ETC_Cobalt_ 4 4 4 4 exe and rename it to Congo exe and place the renamed software file on your USB flash drive in a folder named SOFTWARE not case sensitive Step 3 Connect the USB memory stick to the console Step 4 Start the
13. console and arrow over to the System Settings option and press MODIFY Step 5 Using the trackball or an attached mouse click the SOFTWARE UPDATE button in the Settings dialog This will run the installer Step 6 In the installer accept the software license agreement and then follow the instructions in the installer Note If you are reinstalling Congo click the Repair option at the beginning of the installation process Step 7 In this version the installer will automatically update your IO firmware Please answer the question about which type of hardware you are currently updating to 7 1 1 The installer will then run a number of programs and display a number of dialogs with buttons in them DO NOT CLICK ANY BUTTONS as this will stop the automatic installation of the firmware Step 8 Let the installer run until you see a dialog asking you to acknowledge that the system will need to reboot twice click OK in this dialog The installer will continue to update your console automatically Let it run on its own until you see the Cobalt Cobalt v7 1 1 Release Note Page 8 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 welcome screen displaying in the middle At this point your system has been updated and you can continue working as usual Note In some cases the installer may not automatically find the I O Board causing the installer to hang If it appears that the installer has hung wait 3
14. deo on monitor 1 Page 4 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 Known Issues Remaining in v7 1 1 Continued RND 0001922 RND 0001920 RND 0001914 RND 0001911 RND 0001907 RND 0001906 RND 0001904 RND 0001903 RND 0001901 RND 0001899 RND 0001898 RND 0001897 RND 0001892 RND 0001891 RND 0001890 RND 0001884 RND 0001874 RND 0001868 RND 0001861 RND 0001858 RND 0001830 RND 0001828 RND 0001816 RND 0001811 RND 0001806 RND 0001800 RND 0001793 RND 0001790 RND 0001107 RND 0001104 RND 0001102 RND 0001101 RND 0001087 RND 0001084 RND 0001076 Cobalt v7 1 1 Release Note Devices with reversed intensity profiles go out when returning from freeze until things are refreshed Congo Jr will sometimes show a memory error at shutdown Console mimic does not remember format in recorded screen layouts cRRFU USB receiver unit cannot be configured from Congo Settings UPDATE amp ATTRIB updates correctly but displays wrong quantity of presets updated Ranges are not displayed in Preset Attrib Editor tab in Absolute mode Recording to next available preset number sometimes offers wrong number Workaround Type desired number before recording Changing patch data with multiple patch views open does not refresh data in those other tabs Workaround Edit patch with only one patch view open at a time Text changes to palettes in list view do not update in open channel layout ta
15. dobe Acrobat Reader v8 x and later Please keep this release note with your user manual Compatibility ACN This software is compatible with all Net3 products that meet or exceed ESTA ratified standard ANSI E1 17 2006 Architecture for Control Networks ACN and ANSI E1 31 Streaming ACN sACN e Net3 DMX RDM Gateway Version 1 0 x and later software for RDM communication v5 and later software e Net3 IO Gateway Version 1 0 x and later software e Net3 Show Control Gateway Version 1 0 x and later software e Net3 Remote Video Interface RVI Version 7 1 1 and later software e CEM Version 3 0 and later software e CEM3 Version 1 2 and later software ETCNet2 This release is compatible for the exchange of EDMX and or configuration information with the following ETC hardware and software e Eos Lighting Control System Version 1 2 x and later software Corporate Headquarters m 3031 Pleasant View Road P O Box 620979 Middleton Wisconsin 53562 0979 USA m Tel 608 831 4116 m Fax 608 836 1736 lt London UK m Unit 26 28 Victoria Industrial Estate Victoria Road London W3 BUU UK m Tel Ae MA nap 1000 m Fax 44 0 20 8896 2000 _ Rome IT m Via Pieve Torina 48 00156 Rome Italy m Tel 39 06 32 111 683 m Fax 44 0 20 8 ar Holzkirchen DE m Ohmstrasse 3 83607 Holzkirchen Germany m Tel 49 80 24 47 00 0 m Fax ng io s 47 00 3 00 Hong Kong a Rm a 18 F Tower Phase 1 Enterprise Square 9 Sheu
16. entry IO Gateway Group ID change not dynamically updated in Congo Net3 ACN Device List Gateway Name change not dynamically updated in List Mark intensity should not be scaled Button Macros containing master keys do not transfer from Congo jr to Congo correctly Workaround Rerecord the Macro on the Congo console Client unable to sign on when file server is not on Closing a template editor for any template in play will make Live attributes go blank Workaround Select a channel or Reopen Preset List Illegal Midi Channel 0 Available Workaround Only set legal MIDI channels 1 16 Congo consoles with older video cards may enable only monitor 1 until rebooted Congo v5 0 0 Installer may not run on Light Server using v4 3 x Update Software button Workaround Run installer directly from Windows DispList button in console mimic dock adjusts Congo jr LCD contrast and brightness Workaround Use console settings to adjust contrast and brightness back to normal Using ESC to close Delete Data Wizard may leave previous selections intact Workaround Check all options in this Wizard before executing it after closing it with ESC Learned Macros created in v4 3 x plays may not work in v5 0 0 or later Workaround Re learn Macros using v5 or later software FCB delay not shown correctly in timeline in main playback when not set to absolute values Mac version Import Template Wizard causes hang Video on Congo Sr may not play on monitors 2 and 3 Workaround Play vi
17. ep by copying them to a USB memory stick You can use the Backup Show Archive or File Manager tools on the Utilities tab of the System Settings to quickly copy all shows onto a USB stick If you need to re image your Congo jr hard disk please contact your regional ETC Technical Service office shown at the bottom of the first page to order an upgrade kit These kits are free of charge and contain installation instructions and a USB stick prepared for reimaging your console Please be prepared to provide your console serial number a contact name phone number and shipping address when you call or please include them in your email Once re imaged the hard disk will be updated to the latest image and will already have Cobalt software installed No further updates or installations will be necessary for this version Cobalt v7 1 1 Release Note Page 7 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 Notes About Updating Your Console Running v4 x or v5 x Congo Console Video Issue It is possible for older Congo consoles to experience a video settings problem immediately after reimaging the hard disk to a software version of Congo v6 x or Cobalt version 7 x If you re image an older Congo console and find afterwards that only one monitor is working please power that console down and restart it The video problem should clear itself after rebooting Net3 Services A portion of the Net3 Services was not in
18. er file from the Support section of www etcconnect com Unzip the software and place the Cobalt Family installer file ETC_Cobalt_ 4 4 4 4 4 exe on your USB flash drive in the root directory or a folder named SOFTWARE not case sensitive Please make sure the software file is not inside any other folder or subdirectory as this will hide it from Cobalt s update function Connect the USB memory stick to the console Start the console and touch or click the System Settings option Touch or using the trackball or an attached mouse click the UPDATE tab Using the drop down menu find and touch or click to select the current software installer file Touch or click the INSTALL button This will run the selected installer In the installer accept the software license agreement and then follow the instructions in the installer If you are reinstalling Cobalt click the Repair option at the beginning of the installation process Installation Instructions Cobalt ETCnomad Cobalt Offline Editor and Cobalt Cli ent Step 1 Step 2 Step 3 Download and unzip the Cobalt Family Software installer file from the Support section of www etcconnect com Double click the Cobalt installer file In the Installer click the NEXT button at each step Note If you are reinstalling Cobalt click the Repair option at the beginning of the installation process Click the FINISH button at the end of the installation process Version 7 1 1
19. h latches the first switch on and does not trigger the second independent Workaround Press independent switches one at a time to avoid this behavior Press the first independent switch again to toggle it off Renamed channels appear in Park list using the patched channel number not the Name Congo Console as backup to Light Server with Bypass Startup Screen enabled causes crash Workaround Do not use Bypass Startup Screen when using a Congo console as a backup to a Light Server Returning to On from Freeze sometimes causes channels to turn on Fade w Intensity does not work properly for 16bit RGB Attributes Workaround Control 16 bit RGB without the Fade With Intensity function flagged in the template In some situations Backup consoles can spontaneously activate and take control of the system Congo JR display occasionally goes blank Independent Fade knobs on client do not open in the editor Setup Fader Knob Devices using the Fade With Intensity feature such as RGB LED fixtures will respond correctly to the Grand Master and Intensity wheel but will not be affected by the Blackout switch Using the REFRESH amp CH syntax with selected channels will clear the changed flags from all channels not just the selected channels LEDs on master keys on clients do not update when new content is recorded on server Congo jr as a client will not offer built in alpha numeric keyboard Congo jr Dynamic Effects encoders do not display labe
20. ion actually downloads the firmware This is the actual firmware file Facepanel Preparation Step 1 Begin with the console powered down Step 2 Plug in an external USB Keyboard and mouse Step 3 Hold down the button on the face panel Step 4 Power up the console Step 5 Wait until CONGO logo disappears from the ML screen and gets replaced with a entering diagnostics mode or the diagnostics mode itself appears Step 6 Release the button Keep watching the console monitors Upload Preparation In order to prepare the console for the firmware download a windows file explorer session has to be started Step 7 When the Congo desktop image appears on the monitor immediately press and hold the ESC key on the external keyboard not on the facepanel until a Windows Explorer window appears on screen Step 8 Insert a USB drive containing the unzipped firmware files Step 9 Navigate to the proper directory on your memory stick an attached memory stick usually shows up as drive E Cobalt v7 1 1 Release Note Page 9 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 Firmware upload Step 10 Press the button on the face panel repeatedly until the message Update Firmware NO appears in the ML display Step 11 Press the Setup button in order to change NO to YES Step 12 Press the button again in order to accept this Step 13 Start the Firmware_Downloader exe appli
21. ls for Offset and Delay Relationship however turning the encoder with the wheel key engaged applies these settings Page 5 of 10 Electronic Theatre Controls Inc ETC Release Note A Software Components Cobalt Lighting Control System Software Components Cobalt 7 1 1 9 0 35 Cobalt Settings 1 1 0 9 0 16 Extended Library Version 10 5 3 Wes7 Cobalt 20 1 0 0 9 0 1 Wes7 Cobalt 20 UCB 2 0 0 9 0 3 Wes7 Cobalt 10 1 0 0 9 0 3 Cobalt 10 20 Keyboard Master 1 0 2 9 Cobalt 10 20 Fader Display Unit 1 0 2 9 0 12 Cobalt 10 20 Independent Master 1 0 1 9 0 5 Cobalt 10 20 Playback Master 1 0 1 9 0 6 Cobalt 10 201 0 1 3 0 9 0 5 Wes7 Cobalt Light Server 1 0 0 9 0 1 Cobalt Light Server 10x2 Button 1 1 0 9 0 1 Cobalt Light Server I O 1 3 0 9 0 5 Congo facepanel Software 1 3 01 9 0 001 Congo I O firmware 1 6 0 9 0 5 Congo jr facepanel firmware 1 9 Congo jr I O firmware 1 3 0 9 0 5 Congo Light Server firmware 1 9 Congo Light Server I O firmware 1 3 0 9 0 5 Congo Kid firmware 1 9 Congo Kid I O firmware 1 3 0 9 0 5 Wes7 Congo jr Aaeon 7 0 0 9 0 2 Wes7 Congo Kid Aaeon 7 0 0 9 0 2 Wes7 Congo Light Server Aaeon 7 0 0 9 0 2 Wes7 Puck 1 0 0 9 0 1 Cobalt Software v7 1 1 Running Cobalt software on Congo Congo jr and Congo Kid consoles and Congo Light Servers Cobalt version 7 1 1 software is compatible with Congo family products The following limitations
22. ng Yuet Road Kowloon Bay Kowloon Hong Kong m Tel 852 2799 1220 m Fax 852 2799 9325 Service Americas service etcconnect com m UK service etceurope com m DE techserv hoki etcetcconnect com com m Asia service etcasia com Web www etcconnect com m QSF 4 1 9 1 m Copyright 2015 ETC All Rights Reserved m Product information and specifications subject to change 4370M1100 7 1 1 m Rev B m Released 2015 04 m ETC intends this document to be provided in its entirety Cobalt v7 1 1 Release Note Page 1 of 10 Electronic Theatre Controls Inc ETC Release Note Cobalt Software v7 1 1 e Net3 Four Port Gateway ETCNet2 mode Version 4 0 x and later software e Net3 Two Port Gateway ETCNet2 mode Version 4 0 x and later software e Obsession II Control System Version 5 1 x software e Emphasis Control System Version 1 4 0 and later software e Network Configuration Editor NCE Version 4 0 x and later software e ETCNet2 DMX Node Version 4 0 x software e ETCNet2 Two Port Node Version 4 0 0 thru 4 1 x software Unison Version 1 9 x software For ETCNet2 compatibility e CEM Version 1 x x and later software For ETCNet2 compatibility e DimStat Version 3 1 and later software A CAUTION Cobalt ETCnomad Mac and PC does not support the use of the ETCNet2 protocol See the Incompatibility section General Network Cobalt ETCnomad Version 7 1 1 and later software e Cobalt Client