1. The Balancing port shall not be used for the standard use in the model device Only use the power wires incl plugs to power your model device For perfect conditioning of your LRP VTEC LiPo batteries we recommend the use of our LRP LiPo Parallel Precision Balancer No 45200 For best possible performance and safety always use this balancer when charging your LiPo battery We recommend the use of the LRP LiPo Hardcase balancing wire No 65832 when you are using a LRP Competition Car Line battery The balancing wire allows to plug in the balancer directly without the need of additional soldering work BALANCING PORT PIN ASSIGNMENT Balancing port 3 pole 7 4V packs Power wires incl plugs Black Battery Negative Cell 1 Red Battery Positive _ Brown cell connection Cell 1 Cell 2 Battery Negative Red Battery Positive Cell 2 Balancing port 4 pole 11 1V packs Balancing port 5 pole 14 8V packs e g balancing port 4 pole Balancing port Competition Car Line 7 4V packs 4mm gold plug socket battery Cell 1 2mm gold plug socket cell conn Cell 1 Cell 2 4mm gold plug socket battery Cell 2 e g balancing port 3 pole 2 CHARGING All LRP VTEC LiPo batteries can be charged with a maximum current of 1C For charging only use char gers which are specially designed and developed for LiPo batteries These chargers charge the battery with the max current till the battery reaches the max charg
2. 2 60V LRP VTEC LiPo 14 8V 4S all types 16 80V Nominal capacity of the battery E g with a nominal capacity of 2300mAh 2 3Ah the battery can be charged with a max current of 2 3A PLEASE NOTE You can use your LRP VTEC LiPo battery several times a day However be sure that the battery has completely cooled down to ambient temperature before re charging it again LRP VTEC LiPo batteries do not have a memory effect and only a very low self discharge rate Therefore you can also charge batteries with a partial charge in them without the need of discharging the pack before Partially charged packs can be stored over a long period of time without getting damaged Please also see the Storage section for further reference 256 LitHiUMPOLYMER POWER HIGH CAPACITY HIGH POWER Dear Customer thank you for your trust in this LRP product By purchasing a LRP VTEC Lithium Polymer Ultra Performance 25C battery you have chosen a high performance LiPo battery for your RC model LiPo batteries need special treatment and care Please read the following instructions carefully before you start using your LRP VTEC LiPo battery for the first time and to ensure that your LRP VTEC LiPo battery always works up to your full satisfaction This user guide contains important notes for the installation the safety the use and the maintenance of this product Thus protecting yourself and avoid damages of the product Proceed according to the use
3. AAD03566 IRP electronic GmbH 2009 Y TEC LIPO GAR FLIGHT POWERPAGKS USER GUIDE LRP electronic GmbH Wilhelm Enssle Str 132 134 73630 Remshalden Germany 1 7 E E BLUE IS BETTER info LRP cc www LRP cc f CONNECTION All LRP VTEC LiPo batteries come with properly sized power wires incl plugs The special Competition Car Line Hardcase packs already have 4mm gold plug socket built into the battery pack These power connections have to be used for standard charging and for all applications in the model device Be sure to always take care of the wire colors and the right polarity of the battery as a wrong connection will damage your battery and your speedo While soldering take care that you don t do any short circuits and that all wires are well insulated NOTE Only use a reverse polarity protected plug system for the power wires Additionally to the power connections all LRP VTEC LiPo batteries are equipped with a so called EHR Balancing port This EHR Balancing port can be used to condition and equalize the individual cells inside a battery pack The Competition Car Line Hardcase packs use a 2mm gold plug socket which acts as a cell connection between the two cells in the pack Special balancers or certain chargers use this balancing port to perfectly condition and equalize the indi vidual cells inside the pack Please check the user manual of the balancer charger in order to know how the battery needs to be hooked up NOTE
4. NG Avoid short circuits Short circuiting the battery results in very high currents which damage the inter nal structure of a LiPo battery This leads to a loss of power and capacity Never charge LiPo batteries without a balancer Charging without a balancer can damage the battery Please note that your limited warranty will void if you charge without balancer Be sure not to damage the outside of the LiPo battery The battery inside the hardcase is only protected by a heatshrink The actual Lipo cell is directly under this heatshrink If the outer skin of the cell gets damaged the battery can no longer be used Therefore take special care that no sharp objects like knifes tools carbon fibre edges or similar items can damage the hardcase and or the cells within it When securing the LiPo battery inside your model device you have to take care that the LiPo battery does not get damaged or warped in case of acrash LiPo batteries with a hardcase are less mechanical resistant then NiMH batteries in a metal can Therfore pay special attention that the LiPo battery does not get damaged or warped by letting it fall down hitting it bending it or by similar actions If you want to change the plug system of your LiPo battery take care that you only attach the new plugs to the power wires directly Under no circumstances your allowed to solder directly on the tabs of the LiPo cells Please note that there s the possibility to void your limited warr
5. anty when using a non reverse polarity protected plug system Never charge several LiPo battery packs at once with one charger The different capacities and charge levels can lead to serious overcharging of the battery even if you are using a charger with LiPo capabilities Damaged packs cannot be used any longer If the packs show signs of damage are bent or similar do not use the packs anymore The chemical reaction during charging and discharging a LiPo battery is not fully reversible Due to that LiPo batteries loose capacity during their life span This is normal and not a manufacturing nor production fault DISPOSAL NOTE Damaged packs or packs which can no longer be used are hazardous waste and have to be disposed accordingly Do not dispose the batteries in your household waste Completely discharge the batteries and hand them over to a designated collection point STORAGE LRP VTEC LiPo batteries do not have a memory effect and only a very low self discharge rate Therefore these batteries can be stored over a longer period of time without special treatment You only have to take care that the batteries do not get stored completely empty For a storage over a longer period of time we recommend to charge the battery up to 50 of the nominal capacity Therefore fully discharge the battery pack and then partially charge it with a charge current of 1C for 30 minutes In this condition the battery can be stored at least half a ye
6. ar at 25 C room temperature without the need of recharging it For a storage over a short period of time you also have to pay attention that the battery is partially char ged Never store the battery completely empty Even if you are using your battery regularly every week always pay attention that the battery is partially charged with at least 30 of the nominal capacity during storage A partial charge with 1C charge current for 20 minutes is sufficient in this case if the battery was competely empty before If you pay attention to the above mentioned notes you can enjoy your LRP VTEC LiPo battery for a very long time 6 INTERESTING FACTS ABOUT LIPO BATTERIES LiPo batteries shall only be charged at a temperature between 0 45 C If this will not be observed the cycle life of the battery will be reduced drastically The single cell open voltage of a fully charged LiPo battery is 4 2V The single cell open voltage of a 50 partial charged LiPo battery is approx 3 85V The single cell open voltage of an empty LiPo battery is approx 3 3V A voltage below 3 3V per cell without load is in either case harmful for a LiPo battery Therefore always avoid voltages below 3 3V per cell It is not visible from the outside when a LiPo battery gets overcharged The only way to find this out is to measure the voltage of the LiPo battery The battery does not heat up nor does it swell when it gets overcharged Therefore always check the battery v
7. ars Warranty products the warranty terms on the LRP 25 Years Warranty card do also apply The legal warranty claims which arose originally when the product was purchased shall remain unaffected LRP DISTRIBUTOR SERVICE e Package your product carefully and include sales receipt and detailed description of malfunction e Send parcel to your national LRP distributor e Distributor repairs or exchanges the product e Shipment back to you usually by COD cash on delivery but this is subject to your national LRP distributor s general policy
8. ing voltage The charger then reduces the charging current until the battery is fully charged This charging method is called CC CV Constant Cur rent Constant Voltage ATTENTION Under no circumstances use NiMH NiCd chargers for charging LiPo batteries These char gers do not reduce the charging current and therefore ultimately lead to overcharging the battery LRP VTEC LiPo batteries do not heat up during charging It is normal that the battery still has ambient temperature when it is fully charged If the battery heats up during charging or warps immediately stop charging it A Balancer which monitors the voltage of each single cell is mandatory during the charge of LiPo batteries ATTENTION Never charge your LiPo battery without a balancer directly connected to the balancing port of your battery unless your charger is already equipped with a balancer The maximum charging voltage for each single LiPo cell is 4 20V If the battery reaches this voltage the charge current has to be lowered This is automatically done by the charger If the charge current reaches 0 05 0 1C the battery is fully charged All LRP VTEC LiPo batteries consist of multiple LiPo cells You can see the max charging voltage in the table below We advise the following settings for charging our LRP VTEC LiPo batteries Cell configuration max charge current max charging voltage LRP VTEC LiPo 7 4V 2S all types 8 40V LRP VTEC LiPo 11 1V 3S all types 1
9. oltage during charging If it exceeds the max charging voltage stop the charging process immediately and check all settings We recommend to stop discharging a Lipo battery if the remaining capacity reaches 30 of the nomi nal capacity With this LiPo batteries will have the max possible cycle life Real Life application sho wed that the cycle life of LiPo batteries is reduced if the battery always gets completely discharged This phenomenon can be seen with all types of LiPo batteries 7 USE OF RX ONLY PACKS Due to the nominal voltage of 7 4V of all RX only packs these battery packs cannot be connected directly to the receiver Standard receivers and servos work with a voltage of 6V and therefore will not work properly or get damaged You need our LRP LiPo RX Regulator 6V 5A No 45000 or our LRP Heavy Duty BEC 6V 10A No 45010 to connect a RX only pack to your receiver These regulators reduce the voltage to a safe level of 6V and will be connected directly between the LRP VTEC LiPo RX only battery and the receiver Please see the instruction manual of the regulators for further reference REPAIR PROCEDURES LIMITED WARRANTY All products from LRP electronic GmbH hereinafter called LRP are manufactured according to the highest quality standards LRP guarantees this product to be free from defects in materials or workman ship for 90 days non european countris only from the original date of purchase verified by sales recei
10. pt This limited warranty doesn t cover defects which are a result of misuse improper maintenance outside interference or mechanical damage This especially applies on already used batteries or batteries which show signs of heavy usage Damages or output losses due to improper handling and or overload are not a product fault Signs of wear loss of capacity after intensive usage are also no product fault The following points do also result in a service fee e Original power plugs replaced with a NON reverse polarity protected power plug system e Use of anon reverse polarity protected power plug system e Send in the battery without power plugs e Removed or damaged original heatshrink To eliminate all other possibilities or improper handling first check all other components in your model and the trouble shooting guide if available before you send in this product for repair If products are sent in for repair which do operate perfectly we have to charge a service fee according to our pricelist If LRP no longer manufactures a returned defective product and we are unable to service it we shall provi de you with a product that has at least the same value from one of the successor series The specifications like weight size and others should be seen as guide values Due to ongoing technical improvements which are done in the interest of the product LRP does not take any responsibility for the accuracy of these specs With LRP 25 Ye
11. r guide in order to understand your LRP VTEC LiPo battery better Please take your time as you will have much more joy with your LRP VTEC LiPo battery if you know it exactly This user manual shall be kept in a safe place If another customer is using this product this manual has to be handed out together with it 3 DISCHARGING All LRP VTEC LiPo batteries are capable of amaximum peak discharge current of 25C The continous discharge current for all LRP VTEC LiPo batteries is 15C The continous discharge current for the RX TX only types is 3C PLEASE NOTE Always take care that the battery gets enough cooling when discharging it with high discharge currents You have to take care that the batteries do not get deep discharged As soon as the battery voltage falls below 3 00V per single cell the battery pack gets damaged irrevocably With 2S packs the discharge cut off voltage under load is 6 0V with 3S packs it is 9 0V and with 4S packs the discharge cut off voltage under load is 12 0V The battery voltage should never fall below these discharge cut off voltages If your speed control does not have a special undervoltage protection for LiPo batteries you have to stop your model early enough in order not to deep discharge the battery pack Therefore stop immediately as soon as you feel a rapid loss in power IMPORTANT The max temperature of the LiPo battery during discharge must never exceed 65 C 150 F 4 SPECIAL NOTES FOR HANDLI
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manual timesheet manual transmission manuale digitale manually meaning manual wheelchair manual arts high school manually update your device drivers windows manual labor manual definition manual for courts martial manual muscle testing manual muscle testing grades manually register devices with autopilot manual keyboard manual blood pressure cuff manualidades manual lawn mower manual transfer switch manual transmission cars for sale manual therapy cpt code manual libs manual autopilot enrollment