F & SC Serial Access Control Station

image

Contents

1. 19 3 3Fixing Access Control Station i 20 4 Fastening Access Control Station eee ce eeeeeeeceeeeeeeeees 21 ND o o e AAI ET EA EENIA A EE IA T E OTA TI 22 BT S A ERA OEE EAA E A cong bute 22 5 2 Anti dismantle button i 22 5 3 Cable doorbelli imitata aa nali 23 Access Control Station Installation Guide 1 Before Installing 1 1 Notice about installing Access Control Station is a mass produced product It strictly tested comply with the standard of China U S A and EU This file contains important information It is better for you to read it carefully prior to use If you ignore it the incorrect installation may cause the unit damage Although we could do our best to offer you service the neglect to the file could cause unwanted cost for you 1 Before installation please make sure the power is cut off because it is very dangerous if the power is on The short circuit of power cable may cause the core parts damage 2 All exposed part of connection wire end cannot be exceeded 5mm to prevent the bared wire accidental connection which leads to machine break down And also suggest using different color cable to connect 3 In the place where the static is strong or in winter please connect the grounding firstly in order to prevent the instant mass static damage the machine 4 Connect power supply with device in the last for the wiring connection If you find
2. Access Control Station Installation Guide 4 Fastening Access Control Station After all system installation finished make a test and examine prior to power on inspect whether the lock driver is OK or not for more details please see User Guide and Software Manual Othe green LED begins to glitter after power up enter menu Option Auto test enter menu User manage User Enroll Fingerprint Enroll Enroll a fingerprint and use the fingerprint to test access control system and door lock if there is no any problem Please delete this enrolled fingerprint 21 Access Control Station Installation Guide 5 Others 5 1 Reset Due to operation error or other accidence which leads the machine not to work you can restart machine through reset key take a small tool which diameter is no more than 2mm find reset mark of res on the left small hole on the bottom of device see following figure Use the tool plug into the hole refer to the picture on right then plug out The machine is able to restart 5 2 Anti dismantle button Anti dismantle button is on middle of device whose function is realized by back cover pressing the anti dismantle button When the device is being dismantled it will send an alarm signal through the terminal 22 Access Control Station Installation Guide 5 3 Cable doorbell There is a key which is remark as icon amp 4 on the keypad this key is
3. it up see figure 3 then take away the mounting plate 8 Determine the position of mounting plate on the wall The Access Control Station should be mounted on the external wall of the door approximately 1400mm from the ground to the unit bottom After the position is determined you could drill a hole 18mm 20mm for cable out see below figure shadowed part 4 Make the hole of mounting plate meet the drilled hole on the wall Use the screw to fix it on the wall for the details please see following figure after installation please make sure the mounting plate is reliable fasten not loosed Access Control Station Installation Guide 3 2Connect with peripheral equipment Caution Do not to connect peripheral equipment before the power of the device is cut down otherwise it is possible to damage the device badly Please follow instruction to connect peripheral equipment Door sensor connection sensor GND Exit button connection Button GND Alarm connection Alarm Alarm Door lock connection NC COM NO Ethernet connection RJ45 1 RJ45 2 RJ45 3 RJ45 4 RS232 connection 232RX 232TX GND RS485 connection 485A 485B Wiegand output connection WD0 WDI GND Cable Bell Bell Bell Power connection GND 12V 9000000000 Cable socket a Access Control Station Installation Guide il 4 0000 Ooooo0oo00000 HOoooooooF I J Ta a oooada0 li Ho
4. used for doorbell Door Bell Put the doorbell in the proper place press the doorbell key on the device please see circle marked after the doorbell receive a signal it will ring Note Because the terminal and key our provided is used for cable doorbell must join the power into the electric round 23
5. F amp SC Serial Access Control Station Installation Guide About this Guide The F amp SC Access Control Station User guide is designed to provide information to install the F amp SC serial Access Control Station for operation and configuration please refer to the corresponding user s manual e Not all function these guides introduce available in combination all is option e About your machine function please consult our company technical personnel or the sales personnel Information in this document is subject to change without notice Access Control Station Installation Guide Contents 1 PBefore MStAl a sts ett oa a ira a laga 1 1 1 Notice about installing ii 1 2SystemiContiguration iiua i snara at da et 4 2 1 The illustration of system construction in 4 2 2 The sketch map of communication i 5 3 Installationi rcaiia iaia 6 3 1 Fixing mounting plate cee cece ceeceeeeseeseeneeeeeaes 6 3 21 Door SONSOF essare aee reniei devas seats 9 3 2 2 RELEASE Buttons ii Hebe etan ra ag 9 3 23 Alamm oatel o AL LANIER A 9 3 2 4Conntion with LOCK eee ianiai 10 3 2 5 Ethernet connection e 14 3 2 6 Connection with RS232 ie 16 3 2 7 Connection with RS485 ii 17 3 2 8 Wiegand O tp t a essa 18 3 2 9 Power connection 19 3 2 9 Connect with external Weigend reader
6. al by Access control station NC lock connection Access Control Station and lock powered by independent adapters jump 1 2 closed o000000000 l lt sj HETET 4 the output relay signal by Access control station NO lock connection 13 Access Control Station Installation Guide Access Control station and lock powered by independent adapter Hawn ail O O O O O O O O a 3 25 Ethernet connection 1 Access Control Station connects with PC through cross cable IP 192 168 1 201 Mask 255 255 255 0 IP 192 168 1 101 Mask 255 255 255 0 2 Access Control Station connects with PC through network and HUB to create a local network 14 Access Control Station Installation Guide Switch 3 RJ45 plug wiring diagrams for Ethernet a RJ45 plug standard 1 8 CI TOP FRONT 1 8 b Ethernet 10 100Base T Crossover Cable mostly apply to HUB and Switch or directly connect two Ethernet terminals not through HUB fully support 10Base T and 100Base TX Plug Pin Pin Plug 2 TX 1 lt gt 3 RX TX 2 lt gt 6 RX RX 3 lt gt I TX 15 Access Control Station Installation Guide RX 6 lt gt 2 TX c Ethernet 10 100Base T Straight Thru Cable Support 10Base T and 100Base TX apply to connect with network card and HUB or network outlet sometime it is called whips Wiring standard Pin Color Pin Wiring standard TX 1 lt white
7. any unusual thing occur please firstly cut off the power then go to examine Keep in mind wiring operation under power on will lead to machine sudden damage we are not liable for damages and trouble due to such operation 5 The height to mount device is about 1 4 1 5 meter oe Access Control Station Installation Guide After installation please take off protection film on the fingerprint sensor to get best recognize result 6 After installation finish when go to test the exit door button please keep a personal in the outside because sometimes the accidental issue can bring on you are not able to go outside 7 Our equipment offer an automatically function please after the installing finish Run the auto test function to confirm the installation finish 8 We recommend using above the 12V 3A direct current supply for ZK software s access control device electricity lock better to powered by 12VDC and no more than 1 5 A electric current At this time the electric current of supply should be abovelA than lock power If the parameter of lock power surpasses this scope please connect technical personnel If the power had not met above requests it possibly causes to be unable normally to drive the electricity lock even damage the device 9 Before device to be connected please read and always follow Quick connect Guide closely Because the wrong wiring will cause the core block and sensor to burn out insult in device
8. go out the input equipment such as action detector press sensitivity floor board or exit door button all serve as source to send signal if nobody send out request to want to go out the input keep disconnection if somebody want to go out they trigger release door button the circuit is closed Produce state change the controller responded to the request unlock and permit door serve as passage mode Note the process of performance to unlock door is control by relay when you install door lock there are two thing you must think about safety and security in other words do you want which result that is if lose control of this door the door is still in safety lost control but safety or if lose control of this door the door still is security lost control but security Lost control but safety is that the power supply cut off maybe the power supply is cut or the controller lose control of itself the door will be open automatically and permit everybody freely to pass in and out the door is not ability to be closed until the system power on these type of doors are installed in the protective area which ensure everybody is able to pass in and out One cc representative application of lost control but safety is to use electromagnetism lock under normal power supply the door is controlled by the controller once the power supply break off the electromagnetism lock will lose magnetism and does
9. m long distance transfer should be taken into consideration when selecting the cable of electric power The door lock should be installed reliable and stable Ensure the wiring is correct For the strike lock and electromagnetic lock you should pay attention to positive and negative terminal connection The unused bare end of wire should be cut off and use insulating tape to wrap it The delay time of strike lock is adjustable according to different conditions Normally close NC under normal state the equipment keeps up closed if force the equipment open the circuit cut off brings out the state change Normally Open NO under normally state the circuit is cut off if force the equipment open the circuit will be closed and produce a state change Power Ground GND Current loop ground Input terminal of door sensor Sensor GND the input port of door sensor 10 Access Control Station Installation Guide accepts the signal which come from normally closed contact to detect the door opening and closing state when the door is in closed the contact keep in closed state if the door is opened by someone the circuit break thus bring out state change If unauthorized user opens this door or opening time is too long the controller will send alarm Input terminal of release door button Button GND The input port of release door button accepts the signal which come from normally opened contact to indicate that somebody want to
10. nl WD0 Green Output Wiegand data 0 signal Pin2 WD1 White Output Wiegand data 1 signal Pin3 GND Black Ground 18 Access Control Station Installation Guide 3 2 9 Power connection This device is powered by 12VDC Its current is approximately 50mA in the ready work status and 400mA in the work status The power is conducted along with the terminal you can use the 12V 4A supply adapter that is provided along with the device The detail about connection is as follow Terminal Function Pinl PWR Red Power positive Pin2 GND Black Power negative The following figure is an example which takes a provided power adapter to connect 3 2 9 Connect with external Weigend reader Access control device whit the Weigand input function is able to connect with card reader which is located in outdoor or indoor control the door by the controller together the cable which between access controller and external card reader is no more than 90 meter 19 Access Control Station Installation Guide a Welcome 12 00 07 05 28 Mon 3 3Fixing Access Control Station Confirm all connection plugs correctly Align back iron plate of Access Control Station body to mounting plate properly and push it up see figurel then push device backward see figure 2 Turn and tie up the screw bottom After finishing installation make ensure the body of device is fixed tightly 20
11. not take effect the door become a passage mode Lost control but security is that the power supply cut off the door will be 11 Access Control Station Installation Guide locked automatically do not permit external personal to come in but permit internal personal go out the door is not to be unlocked until the system power supply is in gear Make sure that the door of lost control but security will be installed in the area which needs to be protected through fair and foul One representative application of lost control but security is to use electrical lock if the power supply break off the external personal is not able to open the door but the internal person can open the by manual operation In the following three cases we recommend that fingerprint machine and lock be powered separately 1 The working voltage of the lock is DC12V but the current difference of the fingerprint machine and the lock doesn t exceed 1A 2 The lock voltage is not DC12V 3 The distance between lock and fingerprint machine is too far 1 NC lock connection Access Control Station and lock power by one adapter together Jump 2 3 pin closed a o O O O O O O O 2 NO lock connection Access control Station and lock powered by one 12 Access Control Station Installation Guide adapter together Jump 2 3 pin closed Hati nm al o o O O O o D O m O 3 the output relay sign
12. ooooooon I Access Control Station Installation Guide 3 2 1 Door Sensor The door sensor is used to detect the door open close status Access Control Station can monitor if the door has been unauthorized open through the door sensor at this time it can output a alarm signal moreover Access Control Station can trigger prompt warning if after surpassing a timed period the door still open 3 2 2 Release Button The exit button is installed for in door operation When the switch of the button is close the door will open The distance is approximately 1400mm from ground to exit button bottom Make sure that the exit button position is to align correct upright and the connection is accurate and reliable Unused exposed end of cable should be cut off and use insulating tape to wrap it Pay attention to electromagnetic disturbance For example The light switch the computer and so on 3 2 3 Alarm Access Control Station alarm output is a switch signal it is able to connect with simple alarm by serial circuit it also apply to top grade alarm and monitor system as a trigger signal this machine alarm function only support 12 VDC Warner Access Control Station Installation Guide AL reen No White BUT purpl e Release Button GND Black Door Sensor SEN Yellow 3 2 4Conntion with lock The way of installing door lock depends on the type of lock and local condition Internal resistor which comes fro
13. orange gt 1 TX TX 2 lt Orange gt 2 TX RX 3 lt white green gt 3 RX 4 lt Blue gt 4 5 lt Blue white gt 5 RX 6 lt Green gt 6 RX 7 lt White brown gt 7 8 lt Brown gt 8 3 2 6 Connection with RS232 The definition of PC connection with Access Control Station PC Serial Port Access Control Station serial port Pin2 Rxd Pin1 Txd Purple Pin3 Txd Pin2 Txd Yellow Pin5 Gnd Pin3 Gnd Black 16 Access Control Station Installation Guide 3 2 7 Connection with RS485 The definition of terminal connection Terminal Function Pin1 485A Green RS 485 communication Pin2 485B White RS 485 communication sa b ui si i A 485A 4858 a RS485 Bus X Access Control Station Installation Guide 3 2 8 Wiegand output Access Control Station provide standard Wiegand 26 output which can be connected to most of access controllers like the way of connecting with a ID reader or password keyboard The distance from the controller to device cannot be more than 15 meter if the signal must be transferred much further or there is a strong interference around please adopt a Wiegand signal amplifier Mote no matter the device is powered by access controller or not the ground ports of them have to be properly together to ensure the Wiegand transfer reliable Terminal Function Pi
14. to break down at this cause ZK Software is not liable for any damages and trouble 10 If the space between power adapters and device is too long please do not use the twisted pair or other type ferrules for the power wire When the power wire is choused you should consider attenuation of voltage which has passed long distance transfer 11 Please use specialized RS485 cable and the RS232 485 converter with power to hookup the network the bus structure apply to connect with each device When a long cable is used to transfer signal it is need to connect a matching resistance to receiver and its value is Dia Access Control Station Installation Guide 120Q 12 Other more details items please see also the user manual the operating instructions and the appendix and so on Access Control Station Installation Guide 2System Configuration 2 1 The illustration of system construction RS6 85 TOPP RS232RS489 Convertor Card Release reader button Access Control Station Installation Guide 2 2 The sketch map of communication Access Control Station directly connects with PC through RS232 or TCP IP TCP IP or RS232 Access Control Station Installation Guide 3 Installation 3 1 Fixing mounting plate Take out a Access Control Station dismantle the screw between machine body and mounting plate until it is out see figure 1 Carefully take up the bottom of mounting plate see figure 2 push