Home

Component Manager 2.2 Installation Guide

image

Contents

1. list d Click Stop 2 Add host name to the file a Change to the install path etc opt SUNWesm SUNWencc etc directory as indicated If you used the default directory the path would be as follows C cd Program Files Sun Microsystems StorEdge etc opt SUNWesm SUNWencc etc b Edit the file enclMgr_rs_message_formats cf to contain the following line mailHost hostname where hostname is the host for the mail transport agent 3 Add the email address See To Enable Remote Reporting in Configuring With Component Manager in the Sun StorEdge Component Manager 2 2 User s Guide 12 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Configuring Component Manager for a Sun StorEdge T3 Array This section contains the procedures to configure Component Manager to operate with the Sun StorEdge T3 arrays m Configuring the hosts File on page 13 Configuring the hosts File You must add the IP address and the component name of the Sun StorEdge T3 arrays to the your_installation_directory etc opt SUNWesm mo hosts file so that Component Manager can communicate with them To Configure the hosts File Use an editor to make an entry in your installation directory et c opt SUNWesm mo hosts The default for your installation directory is C ProgramFiles Sun Microsystems StorEdge The entry format is shown below Component Manager 2 2 Component table Each compon
2. 5 To Restart the Software 16 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Preface The Sun StorEdge Component Manager Installation Guide for the Microsoft NT Operating Environment provides instructions for installing the Sun StorEdge Component Manager 2 2 software verifying the installation starting the software and uninstalling the software Before You Read This Book For the latest Component Manager information please see the Sun StorEdge Component Manager 2 2 Release Notes Typographic Conventions TABLE P 1 Typeface Meaning Examples AaBbCc123 AaBbCc123 AaBbCc123 The names of commands files and directories on screen computer output What you type when contrasted with on screen computer output Book titles new words or terms words to be emphasized Command line variable replace with a real name or value Edit your login file Use 1s a to list all files 2 You have mail o s su Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filename Related Documentation TABLE P 2 Application Install User Release Help Install Us er User Title Sun StorEdge Component Manager2 2 Installation Guide For the Solaris Operating Environment Sun StorEdge Component Manager 2 2 User s Guide Sun StorEdge Component Manager 2 2 Rel
3. Component Manager for a Sun StorEdge T3 Array on page 13 Starting Component Manager on page 14 Note You should read this chapter before attempting to install or operate Sun StorEdge Component Manager on a Sun StorEdge T3 array Introduction to Sun StorEdge Component Manager Sun StorEdge Component Manager is a graphical interface that enables you to monitor and manage subsystem storage enclosures Component Manager 2 2 supports Sun StorEdge T3 components and operates under the Solaris 2 6 Solaris 7 and Solaris 8 operating environments as well as the Windows NT operating environment Specifically Component Manager provides status monitoring alarm notification email and remote service support functionality and control capability for a single enclosure or multiple enclosures where management information is accessible by a single host via ethernet Component Manager 2 2 Requirements This section describes the following Component Manager 2 2 requirements m Disk Space on page 2 m Browser on page 2 m Memory on page 3 m Operating Environment on page 3 m Patches and Firmware on page 3 Disk Space Component Manager reguires a minimum of 1300 Mbytes of disk space Browser If using Microsoft Internet Explorer you must have version 5 5 installed for the browser version of Component Manager 2 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Me
4. Manager in one of the following ways m Select the No I will restart my computer later radio button click Finish and proceed with To Enable Microsoft NT Email Notification on page 12 and To Start the Sun StorEdge Management Console GUI Version on page 15 Caution Selecting the Yes I want to restart my computer now radio button as directed below will not allow you to configure StorEdge T3 disk arrays without 1 exiting Component Manager 2 Stop any currently running Component Manager daemon on page 16 3 Configuring Component Manager on page 12 4 Configuring Component Manager for a Sun StorEdge T3 Array on page 13 5 To Manually Starting the Component Manager Daemons on page 14 and 6 To Start the Sun StorEdge Management Console GUI Version on page 15 m Select Yes I want to restart my computer now radio button and click Finish Continue with Configuring Component Manager on page 12 Installing Sun StorEdge Component Manager 11 Configuring Component Manager Configuring Component Manager on Microsoft NT consists of m To Enable Microsoft NT Email Notification on page 12 v To Enable Microsoft NT Email Notification 1 Stop the ESMService if it is running If running you must stop the ESMService a Open the Start menu and select Start gt Settings gt Control Panel b Double click on Services c Select ESMService from the
5. R amp SUN microsystems SUN StorEdge Component Manager 2 2 Installation Guide For the Microsoft NT Operating Environment Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 U S A 650 960 1300 Part No 806 6646 10 April 2001 Revision A Send comments about this document to docfeedback sun com Copyright 2001 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 U S A All rights reserved This product or document is distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Solaris Sun StorEdge Jiro Jini Java2 JDK and Sun Enterprise SYMON are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are base
6. To remove the Sun StorEdge Component Manager software perform the following 1 Stop the Component Manager daemon a Open the Control Panel b Double click Services c Select ESMService in the list d Click Stop 2 Open the Menu and select Start gt Settings gt Control Panel a Click on Add Remove Programs 3 Remove Component Manager a Select Sun StorEdge Component Manager from the list b Click Remove c Click OK to confirm removal d Click Finish to acknowledge removal 4 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Remove the Management Console a Select Sun StorEdge Management Console from the list b Click Remove c Select the Remove radio button then click Next d Click OK to confirm removal e Click Finish to acknowledge removal Remove the Jiro Runtime Environment Component Manager 2 2 only a Select Jiro Runtime Environment Standard Edition 1 0 1 from the list b Click Remove c Click Yes to confirm removal d Click OK to acknowledge removal Remove the Java 2 Runtime Environment a Select Java 2 Runtime Environment Standard Edition v1 2 1 from the list b Click Remove c Click Yes to confirm removal d Click OK to acknowledge removal Remove Cygwin a Select Cygwin B20 from the list b Click Remove c Click Yes to confirm removal d Click OK to acknowledge removal Exit the Control Panel Reboot Note Note the uni
7. art the installation script a Navigate to the following executable file lt cdrom gt Component_Mgr WinNT_4 0 StorEdgeComponentManager exe b Double click StorEdgeComponentManager exe c Click Next at the Sun StorEdge Component Manager Setup window to continue To install Component Manager the Sun StorEdge Management Console must be installed which in turn requires the installation of Cygwin the Java 2 Runtime Environment and Jiro The installation script checks for all of this software and will prompt for approval before installing any software that is missing Installing Sun StorEdge Component Manager 7 v To Install the Sun StorEdge Management Console If the Sun StorEdge Management Console is not installed you will be prompted whether to install it 1 Click Yes to continue 2 Click Next at the Sun StorEdge Management Console Setup window 3 Click Yes to accept the License Agreement 4 Click Yes after reading the Read Me 5 Choose the destination folder in one of the following ways m Click Next to accept the default folder m Click Browse to navigate to another location 6 Choose the type of installation a Select Typical from the list b Click Next 7 Choose the destination name in one of the following ways m Click Next to accept the default name m Enter another name navigate to another location and click Next 8 Configure Web Server a Select the radio button of t
8. d upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements Federal Acquisitions Commercial Software Government Users Subject to Standard License Terms and Conditions DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2001 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des ti
9. ease Notes Part Number 806 6645 806 6647 806 6648 Sun StorEdge Component Manager Online Help Switch Management Installer s User s Manual SANbox 8 Fibre Channel Switch Installer s User s Manual 875 1890 875 1881 vi Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Accessing Sun Documentation Online The docs sun com web site enables you to access Sun technical documentation on the Web You can browse the docs sun com archive or search for a specific book title or subject at http docs sun com http www sun com products n solutions Ordering Sun Documentation Fatbrain com an Internet professional bookstore stocks select product documentation from Sun Microsystems Inc For a list of documents and how to order them visit the Sun Documentation Center on Fatbrain com at http www fatbrain com documentation sun Preface vii viii Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Installing Sun StorEdge Component Manager This chapter contains the following topics for installing the Sun StorEdge Component Manager 2 2 software in the Microsoft NT operating environment Introduction to Sun StorEdge Component Manager on page 2 Component Manager 2 2 Requirements on page 2 Upgrading to Component Manager 2 2 on page 4 Installing the Software on page 7 Configuring Component Manager on page 12 Configuring
10. ent entry is specified by its IP address and name IP address Name 123 45 67 890 cafe japan 1 23 45 67 890 ada48 If you will be installing Component Manager on more than one system do not allow any Sun StorEdge T3 array to be configured more than once in any your installation directory etc opt SUNWesm mo hosts file Multiple Component Manager sessions using identical host file entries might cause arrays to hang under certain operations Installing Sun StorEdge Component Manager 13 Starting Component Manager For Component Manager to start the Component Manager daemons must be running If you rebooted your system after installing Component Manager the daemons will run automatically and you can start Component Manager with the instructions appropriate for your installation However there may be situations when you will want to manually stop and start the Component Manager daemons without rebooting your system Under such circumstances see To Manually Starting the Component Manager Daemons on page 14 This section contains the following topics To Manually Starting the Component Manager Daemons on page 14 To Start the Sun StorEdge Management Console GUI Version on page 15 To Start the Sun StorEdge Management Console Browser Version on page 15 To Restart the Software on page 16 v To Manually Starting the Component Manager Daemons This procedure describes how to start the Componen
11. ers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun AnswerBook2 docs sun com Solaris Sun StorEdge Jiro Jini Java2 JDK et Sun Enterprise SYMON sont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d uti
12. es c Select ESMService in the list d Click Stop Note After ESMService has stopped it may take a few moments before various background processes have shut down You can monitor the shut down process with with the Performance tab of Task Manager 2 Perform these procedures a To Manually Starting the Component Manager Daemons on page 14 b To Start the Sun StorEdge Management Console GUI Version on page 15 16 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001
13. he installation you desire and click Next Note You will need the values from the following two steps in order to start the browser version of Component Manager see To Start the Sun StorEdge Management Console Browser Version on page 15 b Enter the Web Server Administrator password confirm the password by entering it again and click Next Note Do not use a in the password c Configure ports in one of the following ways m Accept the default entries and click Next m Over ride the default settings by typing over themwith a value between 2 and 65535 and clicking Next 8 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 To Install Cygwin If Cygwin is not installed you will be prompted to install it Click Yes to proceed with the installation Clicking No will abort the installation of Cygwin the Sun StorEdge Management Console the Java 2 Runtime Environment Jiro and Component Manager Click Next at the Welcome window Click Yes to accept the License Agreement Click Next at the About Cygnus Solutions Welcome Box Choose the destination folder in one of the following ways m Click Next to accept the default folder m Click Browse to navigate to another location Choose the folder name in one of the following ways m Click Next to accept the default folder name m Enter the name of the folder Click Finish to proceed with the supplemental installati
14. igured in the etc directory esm detached is completely configured in the package contents database esm embedded is not configured in the etc directory esm embedded is not configured in the package contents database etc opt SUNWesm www conf server xml is configured with non secure port ID 8180 etc opt SUNWesm www conf server xml is configured with secure port ID 8443 2 After the Component Manager daemons have been started either manually using the procedure on page 14 or automatically if you rebooted your system browse Component Manager by one of the two methods below o For a secure web server enter a URL with the following format in a browser https nodename domain port number login An example using the default port number would be https happy japan 8180 login Installing Sun StorEdge Component Manager 15 For a non secure web server enter a URL with the following format in a browser http nodename domain port number login An example using the default port number would be http happy japan 8180 login See the Sun StorEdge Component Manager 2 2 User s Guide for more information about using Component Manager v To Restart the Software Use the following steps to stop and restart the management stations if the software fails to start automatically 1 Stop any currently running Component Manager daemon a Open the Control Panel b Double click Servic
15. lisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A UAPTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON Od a GA Adobe PostScript Contents Preface v Installing Sun StorEdge Component Manager 1 Introduction to Sun StorEdge Component Manager 2 Component Manager 2 2 Requirements 2 Disk Space 2 Browser 2 Memory 3 Operating Environment 3 Patches and Firmware 3 Upgrading to Component Manager 2 2 4 v To Uninstall the Software 4 v ToRemove persistence files 6 Installing the Software 7 v ToStartthe Installation Script 7 v To Install the Sun StorEdge Management Console 8 v To Complete the Installation of the Management Console 10 v To Install Component Manager 11 Configuring Component Manager 12 iv v To Enable Microsoft NT Email Notification 12 Configuring Component Manager for a Sun StorEdge T3 Array 13 Vv Configuring the hosts File 13 To Configure the hosts File 13 Starting Component Manager 14 v Y Y Y To Manually Starting the Component Manager Daemons 14 To Start the Sun StorEdge Management Console GUI Version 15 To Start the Sun StorEdge Management Console Browser Version 1
16. mory TABLE 0 1 Component Manager Memory Requirements Additional Required per Disk Memory Type Basic Requirement Array or Enclosure Virtual Memory 174 Mbytes 0 5 MBytes CPU Capacity Available 8 As a guideline you should have approximately 50 Mbytes of available physical memory If Component Manager performance is an issue due to system resource requirements move the Component Manager application to another server with less load and monitor the disk arrays from that server Sun StorEdge T3 disk arrays are monitored through an ethernet so Component Manager does not have to run on the same host to which the Sun StorEdge T3 disk arrays are attached Operating Environment m Component Manager 2 2 supports the Microsoft Windows NT 4 0 service pack 6 Patches and Firmware Use the Advanced Search link on the following web site for the latest patches or Sun StorEdge Sun StorEdge T3 firmware http sunsolve sun com Installing Sun StorEdge Component Manager 3 Upgrading to Component Manager 2 2 If you are installing Component Manager software for the first time go to Installing the Software on page 7 otherwise uninstall Component Manager if you are upgrading from Component Manager 2 0 or 2 1 In addition if you are upgrading from Component Manager 2 0 you must remove the persistence files m To Uninstall the Software on page 4 m To Remove persistence files on page 6 v To Uninstall the Software
17. nstallation procedure will remove the etc opt SUNWesm mo hosts file See Configuring the hosts File on page 13 Installing Sun StorEdge Component Manager 5 v To Remove persistence files When upgrading from Component Manager 2 0 you must remove the persistence files Remove the persistence files with Windows NT Explorer or by typing cd Program Files Sun Microsystems STOREDGE var opt SUNWESM mc persistence del grf cd Program Files Sun Microsystems STOREDGE var opt SUNWESM mo persistence del grf 6 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 Installing the Software Installing the software is a simple process taking up to 15 minutes to complete You must have Administrator privileges to correctly install the software m To Start the Installation Script on page 7 m To Install the Sun StorEdge Management Console on page 8 To Install Cygwin on page 9 To Install the Java 2 Runtime Environment on page 10 To Install Jiro on page 10 m To Complete the Installation of the Management Console on page 10 m To Install Component Manager on page 11 To Start the Installation Script Load the Component Manager 2 2 CD with the label side facing up into the CD ROM drive Start Windows NT Explorer by selecting from the Start menu gt Programs gt Windows NT Explorer Select the CD ROM drive in the left panel St
18. ons Installing Sun StorEdge Component Manager 9 V To Install the Java 2 Runtime Environment If the Java 2 Runtime Environment JRE is not installed you will be prompted to install it 1 Click Yes to proceed with the installation Clicking No will abort the installation of the JRE Jiro and Component Manager 2 Click Yes to accept the License Agreement 3 Choose the destination folder in one of the following ways m Click Next to accept the default folder m Click Browse to navigate to another location V To Install Jiro If Jiro is not installed you will be prompted to install it 1 Click Yes to proceed with the installation 2 Click Next to continue 3 Accept the License Agreement a Select the Yes radio button b Click Next 4 Click Next after reading the Readme 5 Choose destination folder in one of the following ways m Click Install to accept the default folder m Click Choose to navigate to the desired location 6 Click Next after acknowledging the need to reboot 7 Click Done v To Complete the Installation of the Management Console o Click Finish to complete setup and continue with the installation of Component Manager 10 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 v 1 2 To Install Component Manager Click Yes to accept the License Agreement Click Next to begin copying files Start Component Manager At this point start Component
19. t Manager software without rebooting the system If you have already rebooted the system see To Start the Sun StorEdge Management Console GUI Version on page 15 1 Open the Control Panel 2 Double click on Services 3 Select ESMService in the list 4 Click Start Note After ESMService has started it may take a few moments before various background processes to complete You can monitor the startup process with the Performance tab of Task Manager You are now ready to start the Sun StorEdge Management Console 14 Sun StorEdge Component Manager 2 2 Installation Guide NT Version April 2001 v To Start the Sun StorEdge Management Console GUI Version After the Component Manager daemons have been started either manually using the proceeding procedure or automatically if you restarted your system start Component Manager by opening the menu Start gt Programs gt StorEdge gt Start Management Console See the Sun StorEdge Component Manager 2 2 User s Guide for more information about using Component Manager v To Start the Sun StorEdge Management Console Browser Version 1 Determine port number You will need the port number you entered during the installation process You can determine this with the following C ed ProgramFiles Sun Microsystems StorEdge usr opt SUNWesm sbin C esm configweb s esm configweb Status for th sm detached or esm embedded web server esm detached is completely conf

Download Pdf Manuals

image

Related Search

Related Contents

Samsung GT-P3110 Užívateľská príručka (Jellybean)  Zoomax Capture Video Magnifier User Manual  Practice Resource  Neevia docuPrinter SDK v6.7 user manual  2N EntryCom IP Safety  User`s manual - Pdfstream.manualsonline.com  Contrôle des pratiques commerciales, de la conformité et de la    TP-Link TL-WN722NC Declaration of Conformity  USER`S MANUAL S. & A.S.  