Home

User Manual Optimal Extension

image

Contents

1. Care of sweden Supporting Life User Manual 2015 03 10 Optimal Extension Item no user manual 95 001292 NI CE 331345 Contents Important safety instructions 2 Introduction 3 Instruction for use 3 Cleaning 4 Other information 5 Own notes 7 IMPORTANT SAFETY INSTRUCTIONS Read all instructions prior to use WARNING 1 The product must only be used for its intended purpose as described in this manual The product may not be combined fitted or repaired with other parts accessories or spare parts other than those described in this manual or other documentation published by Care of Sweden 2 Do not use in the vicinity of or in contact with fire sources hot surfaces such as fire burning cigarettes or hot lamps Although the product has undergone fire testing it could become damaged if it comes into contact with naked flames 3 The product does not allow liquid or air to penetrate but is vapour permeable Make sure that the patient is positioned correctly to avoid the risk of suffocation 4 Please try to avoid the simultaneous use of multiple hygiene covers with this product Because of the risk that the vapour permeability can be destroyed 1 Introduction Always read the user manual prior to use 1 1 General information This product is a medical device in accordance to MDD 93 42 EEC According to statutory regulations made by the authorities
2. short mattress to fit the bed If the mattress cover is equipped with handles or straps at the head or foot end the extension can be attached to these using the Velcro straps If the cover has nothing to attach to place the extension so that it is held in place between the mattress and headboard Make up the bed with sheets to increase user comfort 3 Cleaning It is important to follow the instructions below before the product is re used for another user Consult the hygiene responsible or the supplier for help and instructions when unsure HYGIENE COVER 357 Q ll Bet RY The cover can be machine washed at max 95 C and tumble dried or drip dried Covers can be wiped off with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Excrements and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner AN Chlorine and phenol based cleaners could adversely affect the PU surface and should be avoided If chlorine is used we recommend a mixture of max 1 lt 1 FOAM CORE Clean the affected area with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Gently squeeze out water NB Don t wring or roll the foam core to extract water Let the core dry in a warm ventilated a
3. he complaint has been reported Damages due to the transport should be reported to the transportation agent 4 9 Symbol Definitions ma XXXX XX XX Article No Manufacturer Year Month Day Read the user manual CE a lt CE marked acc to Recycling Machine wash at 95 C 7 Chlorine MDD 93 42 EEC Q m Bi Tumble dry Drip dry Do not iron Do not dry clean Wipe off 5 Own notes E Manufactured by Care of sweden Supporting Life Contact Phone 46 771 106600 Fax 46 325 12840 Email info careofsweden se Internet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns vag 4A SE 514 33 Tranemo SWEDEN Supplied by Care of Sweden is a trademark of Care of Sweden AB Care of Sweden AB 2015
4. rea not in direct sunlight The foam core must be completely dry before it is used again NOTE Check the hygiene cover each time the product is cleaned If damaged it must be replaced or repaired 4 Other information 4 1 Storage Store the extension on a flat surface with the zipper closed Always store at room temperature in a dry area Make sure the extension is stored where it will not be exposed to thrusts hits or other things that can damage it Avoid direct exposure of sunlight 4 2 Labelling The extension is labelled with product name production date article number size EAN bar code as well as space for own labelling 4 3 Warranty This product is covered by a 2 year warranty The warranty is valid for production errors It is not valid for normal wear or deterioration of the product or damages that occur because of careless handling or care of the product 4 4 Service and maintenance The extension part needs no other service or maintenance than cleaning as described in this user manual 4 5 Life expectancy This product s expected life is estimated to be 3 years 4 6 Repairs For instructions contact the supplier 4 7 Recycling All bed products are fully recyclable and should be recycled as combustible waste No dismantling needed 4 8 Returns and complaints Complaints are to be reported to the supplier Return of a product shall follow the supplier s instructions and can only be done after t
5. regarding medical devices the manufacturer is required to report all accidents or incidents involving our products We would be very grateful for all information involving accidents or incidents relating to our products by reporting them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards SS 876 00 01 SS 876 00 02 SS 876 00 04 EN ISO 12182 EN ISO 14971 EN ISO 10993 1 EN ISO 12952 EN 14126 1 2 Intended use This product is a functional extension for mattresses 1 3 Product description Core HR foam Cover Polyurethane coated polyester fabric 1 4 Other information Action plan Pressure ulcers To achieve the best possible result for this product it is recommended that a well planned and well structured working environment be used In our guideline Action plan you will find examples which can be applied and put into practice when using our products Mattress guide This practical guide gives you as a care giver help in choosing the correct mattress from the Care of Swedens range This information can be found on our website www careofsweden com or you can order a copy from our Customer services by sending your details to info careofsweden se 1 5 Unpacking When unpacking check that no parts are damaged If damages are detected contact Care of Sweden or your local dealer before using the product 2 Instruction for use Optimal Extension is used to extend a