Home
CN2600 Series Dual-LAN Terminal Server User`s Manual
Contents
1. Total Solution for Industrial Device Networking 3 Main Menu Restart Ports ram Overview E Basic Settings Restart the selected serial ports HA Network Settings BI Serial Port Settings Select Ports ES System Management ae Misc Network Settings Eg Auto Warning Settings E Maintenance H Certificate Select All Submit ES System Monitoring Eg Serial Status HE System Status ra Save Configuration Ey Restart c Restart System Y Restart Ports Die Ds O4 Os Ee Oz De Do O10 O11 012 013 014 Das 016 8 18 9 Software I nstallation Configuration The following topics are covered in this chapter O NPort Search Utility gt Installing NPort Search Utility gt Configuring NPort Search Utility O Windows Driver Manager gt Installing NPort Windows Driver Manager gt Using NPort Windows Driver Manager O Windows Monitor Utility gt Installing the NPort Monitor Utility gt Using the NPort Monitor Utility O Linux Real TTY Drivers gt Basic Procedures gt Hardware Setup gt Installing Linux Real TTY Driver Files gt Mapping TTY Ports gt Removing Mapped TTY Ports gt Removing Linux Driver Files O The UNIX Fixed TTY Driver gt Installing the UNIX Driver gt Configuring the UNIX Driver CN2600 Series Software I nstallation Configuration NPort Search Utility Installing NPort Search Utility l Click the INSTALL UTILITY button in the Installation CD auto run window to install NPort Search
2. Server name CN2650 8 2AC D cK Serial Port Settings ee E Porti Server location 9 Port 2 Time Settings E Port 3 Time zone 24 hour GMT Greenwich Mean Time Dublin Edinburgh Lisbon London v H Port 4 Local time 2000 y 1 pl2 4 59 15 Modify oR cole Time server Port 6 H Port 7 aE Porte Welcome Message Cd System Management Ed pa EH 2 System Monitoring CJ Save Configuration EC Restart Server name This is an optional free text field for your own use it does not affect operation of the CN2600 It can be used to help differentiate one CN2600 server from another Server location This is an optional free text field for your own use it does not affect operation of the CN2600 It is useful for assigning or describing the location of a CN2600 In a network environment of multiple servers this can be a valuable aid when performing maintenance Time Settings The CN2600 has a built in Real Time Clock for time calibration functions Functions such as Auto Warning Email or SNMP Trap can add real time information to messages Before making any adjustments to the time first select the correct time zone and submit the change The console will display the real time according to the time zone To modify the real time clock click on Modify next to the Local time field Once you submit the new time the CN2600 s firmware will modify the GMT time according to your time zone an
3. E Dynamic mode integrates PPPD SLIPD and Terminal dial in services Dynamic mode automatically detects which remote connection mode is being used and provides corresponding services You can individually enable disable PPP SLIP Terminal services by selecting Yes or No next to the corresponding option Yes will enable that type of service No will disable it Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description Local Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server None Authentication is not required Disabled Mode Total Solution for Industrial Device Networking 3 Main Menu CJ Overview Operation Modes Ner Basic Settings a Network Settings anm Bel Serial Port Settings Application Disable vj EHE Port 1 P1 Dr Ors Or Ors Ope Or Ops E m Operation Modes Apply the above settings to Call ports a Communication P Y Data Buffering Lo 3 Modem Settings A Port 2 B3 Port 3 B Port 4 BA Ports A Porte eg Port 7 EJ Porte d Welcome Message 63 System Management eg System Monitoring QJ save Configuration HA Restart ES v When the Application is set to Disable the relevant port will be disabled 6 26 7 Additional Serial Port Settings In this chapter we describe additional s
4. be disconnected when a DCD Off signal is received DCD On None A TCP connection will be established when a DCD On signal is received and will pow remain active indefinitely Packet length default 0 This field refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTI ON In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is rece
5. zi RJ45 Port RJ45 Connector CN 2600 8 pins TxD TxD Cable Wiring RxD GND w ma Cc 0 n3 Co RJ 45 8 pins to Male DB9 Male DB9 zi RJ45 Port RJ45 Connector CN 2600 8 pins TxD TxD Cable Wiring RxD GND w C a RJ 45 8 pins to Female DB25 RJ45 Port RJ45 Connector Female DB25 i CN 2600 8 pins E Cable Wiring TxD 2 5 TxD aj SCS RxD 6 lt _ _ ___Y _ 8 RxD 5 lt e 2 GND 3 7 Male DB9 RS 422 4 wire RS 485 Device 9 pins RxD RxD TxD TxD GND Female DB9 RS 422 4 wire RS 485 Device 9 pins RxD RxD TxD TxD GND Male DB25 RS 422 4 wire RS 485 Device i 25 pins RxD RxD TxD TxD GND CN2600 Series RJ 45 8 pins to Male DB25 RJ45 Port RJ45 Connector CN2600 8 pins TxD TxD RxD RxD GND waa nn Cable Wiring Male DB25 Female DB25 RS 422 i 4 wire RS 485 Device 25 pins NWOON 4 RxD RxD TxD TxD GND Serial Cables 2 Wire RS 485 RJ 45 8 pins to Female DB9 F a RJ45 Port RJ45 Connector CN2600 8 pins Data Data GND Cable Wiring Female DB9 Male DB9 2 wire RS 485 Device 9 pins RJ 45 8 pins to Male DB9 y a
6. RJ45 Port RJ45 Connector CN2600 8 pins Data Data GND Cable Wiring Male DB9 Data Data GND Female DB9 2 wire RS 485 Device 9 pins RJ 45 8 pins to Female DB25 RJ45 Port CN2600 8 pins Data Data GND RJ45 Connector Female DB25 Data Data GND Male DB25 2 wire RS 485 Device 25 pins Data Data GND Pinouts and Cable Wiring CN2600 Series RJ 45 8 pins to Male DB25 RJ45 Port RJ45 Connector CN2600 EE 8 pins Cable Wiring Data 5 Data 6 GND 3 Pinouts and Cable Wiring Male DB25 Female DB25 2 wire RS 485 Device 25 pins 3 Data 8 Data 7 GND Pin Assignments for DB9 and DB25 Connectors Pin Assignments for DB9 Male and Female Connectors DB9 Male Connector l 1 DCD in DSR in 6 2RxD dm RTS out 7 3 TxD out CTS in 8 E 4 DTR out 5 GND DB9 Female Connector O DCD in 1 6 DTR out TxD out 2 7 CTS in DH in 3 8 RTS out in 4 d GND 5 Pin Assignments for DB25 Male and Female Connectors DB25 Male Connector k rm 1 2 TxD out 3 RxD in 4 RTS out 5 CTS in 6 DSR in 7 GND DTR out 20 8 DCD in 25 13 gt DB25 Female Connector O 4 RxD in 2 TxD out 3 CTS in 4 RTS out 5 DTR out 6 GND 7 DCD in 8 20 DSR in 13 25
7. a O Terminal Applications gt Terminal ASCII Mode gt Terminal BIN Mode O Reverse Terminal Applications gt Reverse Telnet O Dial I n Out Modes O Disabled Mode CN2600 Series Serial Port Operation Modes Overview The CN2600 network enables traditional serial RS 232 422 485 devices The serial device server is a special purpose computer equipped with a CPU and TCP IP protocols that can bi directionally translate data between the serial and Ethernet formats Your own computer will be able to access manage and configure remote facilities and equipment over the Internet from anywhere in the world Traditional SCADA and data collection systems rely on serial ports to collect data from various kinds of instruments Since the CN2600 network enables instruments equipped with an RS 232 RS 422 or RS 485 communication port your SCADA and data collection system will be able to access all instruments connected to a standard TCP IP network regardless of whether the devices are used locally or at a remote site The CN2600 is an external IP based network device that allows you to expand the number of serial ports for a host computer on demand As long as your host computer supports the TCP IP protocol you will not be limited by the host computer s bus limitation such as ISA or PCI nor will you be limited by the absence of drivers for various operating systems In addition to providing socket access the CN2600 also comes with a Real
8. gj Operation Modes TCP alive check time 7 o 99 min 3 Communication P Inactivity time O0 0 99 min C Data Buffering Lo Auto link protocol None CJ Modem Settings Primary host address Hg Port 2 Secondary host address HE Port 3 HN Porta Telnet TCP port 23 GQ Port 5 Terminal Port 6 Terminal type lansi gt 3 E Hs Authentication type None v J Welcome Message E Automatic Login LQ System Management 9 EMI System Monitoring Auto login prompt ogin 9 Save Configuration lassword Password prompt c ed Restart Login user name Login password P1 Or2 P3 Or4 Ops P6 P7 Ors Apply the above settings to CIAll ports Terminal Binary mode can be used to transfer files with XMODEM or ZMODEM You are only allowed to open one terminal session at a time when in Terminal Binary mode TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive 6 19 CN260
9. 3 Initial IP Address Configuration When setting up the CN2600 for the first time the first thing you should do is configure its IP address This chapter introduces the different methods that can be used Please refer to Chapter 8 System Management Settings for more details about network settings The following topics are covered in this chapter O Static and Dynamic I P Addresses O Factory Default I P Address O Configuration Options Terminal Server Search Utility Web Console LCM Console Front Panel ARP Telnet Console Y Y ON ON Y Serial Console CN2600 Series Initial IP Address Configuration Static and Dynamic I P Addresses Determine whether your CN2600 needs to use a static IP or dynamic IP address either DHCP or BOOTP PPPoE application e If your CN2600 terminal server is used in a static IP environment you will assign a specific IP address using one of the tools described in this chapter e f your CN2600 terminal server is used in a dynamic IP environment the IP address will be assigned automatically from over the network In this case set the IP configuration mode to DHCP DHCP BOOTP BOOTP or PPPoE ATTENTI ON Consult your network administrator on how to reserve a fixed IP address for your CN2600 in the MAC IP mapping table when using a DHCP Server or BOOTP Server For most applications you should assign a fixed IP address to your CN2600 Factory Default I P Address The CN2600 is configured
10. W Fiera COM LAHI LAK jm Fiedurziant DUH LANI LARG i Rederi COM Lani Lan Fiechurgle COM LANI LAHA n Fiedurchani COH Lani LARGI VE Peded COH LANI LAN IE Fikri COH LANI LAHZ Linux Real TTY Drivers Basic Procedures Follow these instructions to map a CN2600 serial port to a Linux host s tty port 1 Set up the CN2600 After verifying that the IP configuration works and you can access the CN2600 by using ping telnet etc configure the desired serial port on the CN2600 to Real COM mode 2 Install the Linux Real tty driver files on the host Map the NPort serial port to the host s tty port Follow these steps to add additional servers as needed Step 1 Modify npreal2d cf file to add an additional server or to remove unused servers Users can use vi or any edit to modify it It s a text file For more configuration information take a look at the npreal2d cf file Step 2 Find the process id PID of program npreal2d ps ef grep npreal2d Step 3 Update configuration of moxattyd program kill USR1 PID ex if npreal2d PID 404 kill USR1 404 ATTENTI ON Please use the mxaddsvr to generate a temporary file for npreal2d cf and follow the temporary file to modify npreal2d cf if user don t know how to modify the npreal2d cf file 9 17 CN2600 Series Software I nstallation Configuration Hardware Setup Before proceeding with the software installation make sure you have
11. DTR RTS 2 8 CTS GND 3 5 GND TxD 4 2 RxD RxD 4 3 TxD DCD 6 1 DCD CTS 7 RTS DTR i 8 6 i DSR CN2600 Series RJ 45 8 pins to Male DB9 RJ45 Port CN2600 8 pins DSR RTS GND TxD RxD DCD CTS DTR RJ45 Connector Male DB9 i Cable Wiring _ ai MM M at aui KIO co C MA COP E 0 P CO m0 RJ 45 8 pins to Female DB25 RJ45 Port CN2600 8 pins DSR RTS GND TxD RxD DCD CTS DTR RJ45 Connector Female DB25 Cable Wiring RJ 45 8 pins to Male DB25 RJ45 Port RJ45 Connector CN2600 8 pins DSR RTS GND TxD RxD DCD GIS DTR Male DB25 Cable Wiring 6 4 _ ff ee 2 3 8 Cd 2 Female DB9 RS 232 Device 9 pins DTR CTS GND RxD TxD DCD RTS DSR Male DB25 RS 232 Device 25 pins DTR CTS GND RxD TxD DCD RTS DSR Female DB25 RS 232 Device 25 pins DTR CTS GND RxD TxD DCD RTS gt 20 DSR Pinouts and Cable Wiring CN2600 Series Pinouts and Cable Wiring Serial Cables RS 422 4 Wire RS 485 RJ 45 8 pins to Female DB9 Female DB9
12. EJ Port 16 E welcome Messag System Log A ae System Managemer aa System Monitoring Eg Serial Status EMEg System Status C3 Network Conne c Network Statis m Serial Data Loc Select all Clear log Refresh K 8 16 CN2600 Series System Management Settings Routing Go to Routing under System Status to display the routing information Total Solution for Industrial Device Networking Routing Current Routing E Iface Destination Gateway f HA Netmask Metric Flag Use Fi Port 10 eth 192 168 127 0 192 168 127 254 255 255 255 1 J 301 E Port 11 83 Port 13 Bg Port 14 EJ Port 16 0 Welcome Messag HL System Managemer ES System Monitoring Eg Serial Status e BG System Status i Network Conni 3 Network Statis E Serial Data Loc 1 system Log 4 Routing E Dout State Save Configuration Go to Save Configuration and then click Save to save the your submitted configuration changes to the CN2600 s flash memory The configuration changes will then be effective when the CN2600 is restarted If you do not save your changes before restarting they will be discarded Total Solution for Industrial Device Networking J Main Menu Save Configuration C Overview ram Basic Settings If vou have submitted any configuration changes you must save the changes and restart the server before they take effect Click Save to save the changes in the NPort 600
13. IP configuration default Static You can choose from four possible IP configuration modes Option Description User defined IP address netmask gateway DHCP DHCP server assigned IP address netmask gateway DNS and time server DHCP BOOTP DHCP server assigned IP address netmask gateway DNS and time server or BOOTP dll server assigned IP address if the DHCP server does not respond I P Address LAN1 default 192 168 127 254 LAN2 default 192 168 126 254 Enter the IP address that will be assigned to your CN2600 All ports on the CN2600 will share this IP address An IP address is a number assigned to a network device such as a computer as a permanent address on the network Computers use the IP address to identify and talk to each other over the network Choose a proper IP address that is unique and valid in your network environment Netmask default 255 255 255 0 Enter the subnet mask A subnet mask represents all of the network hosts at one geographic location in one building or on the same local area network When a packet is sent out over the network the CN2600 will use the subnet mask to check whether the desired TCP IP host specified in the packet is on the local network segment If the address is on the same network segment as the CN2600 a connection is established directly from the CN2600 Otherwise the connection is established through the given default gateway Gateway Enter the IP address of the gat
14. Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would lke Setup to perform while installing MPort Monitor Utility then click Next Additional icons 5 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen fs Setup NPort Monitor Utility Ready to Install Setup is now ready to begin installing MPart Monitor Utility on your computer Click Install to continue with the installation or click Back if you want ho review or change any settings Destination location C Program Files Porth onitor Completing the NPort Monitor Utility Setup Wizard Setup has finished installing NPort Monitor Utility on your computer The application may be launched by selecting the Installed icons Click Finish to exit Setup 9 15 CN2600 Series Software I nstallation Configuration Using the NPort Monitor Utility After you install the NPort Monitor Utility you can monitor the status of the IP address and MAC address for redundant LAN 1 and also for redundant LAN 2 l 2 4 Go to Start gt NPort Monitor Utility to start the monitor utility Click the Search icon PA NPort Monitor Utility Function Run Help yl E sit z Search Stark Stop MAC Address IP Address Click Rescan to se
15. Tatal COM Part 8 E 9 13 CN2600 Series Software I nstallation Configuration Windows Monitor Utility Installing the NPort Monitor Utility The NPort Monitor Utility is used to monitor the status of redundant COM mode connections The utility is designed for use with Windows 95 98 ME NT 2000 XP 2003 Vista l Click the INSTALL Monitor Utility button in the CN2600 Installation CD auto run window to install the NPort Monitor Utility Once the installation program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation iSl Setup NPort Monitor Utility Welcome to the NPort Monitor Utility Setup Wizard This will install MPart Monitor Utility Verl on por computer It is recommended that vou close all other applications before Continuing Click Nest to continue or Cancel to exit Setup Select Destination Location Where should MPart Monitor Utility be installed LJ Setup wall install Port Monitor Utility into the following folder To continue click Nest IF vou would like to select a different folder click Browse Monitor Browse At least 1 1 MB af free disk space is required Back Next gt Cancel 9 14 CN2600 Series Software I nstallation Configuration 4 Click Next to proceed with the installation The installer then displays a summary of the installation options El Setup NPort Monitor Utility
16. by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port Socket Applications TCP Server Mode MOXA Total Solution for Industrial Device Networking 3 Main Menu Er Operation Modes LJ Overview 3 Basic Settings Port 1 Network Settings Application Socket v 23 Serial Port Settings sada Q_ EY Port 1 Mode A Cg Operation Modes TCP alive ch
17. delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits l stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 m
18. link down E mail Alert Z NPort Web Console Microsoft Internet Explorer B x File Edit View Favorites Tools Help Av Y E O Back gt x B A pa P Search 5 2 Favorites 4 f F 2 Address amp http 192 168 127 254 E SE Links Total Solution for Industrial Device Networking 3 Main Menu QJ Overview E Mail Server Settings HJ Network Settings ps Mail server SMTP CO Serial Port Settings E mail Alert ES System Management My server requires authentication EQ Misc Network Settings User name EC Auto Warning Settings Password 7 gg Event Settings From e mail Serial Event Settings address c E mail Alert To e mail address 1 00 C3 SNMP Trap To e mail address 2 Eam Maintenance To e mail address 3 H Certificate H System Monitoring To e mail address 4 ran Save Configuration CJ Restart The E mail Alert settings configure how e mail warnings are sent for system and serial port events You may configure up to 4 e mail addresses to receive automatic warnings ATTENTI ON Consult your Network Administrator or ISP for the proper mail server settings The Auto warning function may not work properly if it is not configured correctly The CN2600 s SMTP AUTH supports LOGIN PLAIN and CRAM MD5 RFC 2554 Mail server This field is for your mail server s domain name or IP address
19. system is used you will always be able to use standard PPP dial up to establish a connection The CN2600 can also act as a router to connect serial ports to a WAN connection Routing protocols including static RIP and RIP 11 can be adjusted to route different WAN connections Please refer to Chapter 5 Configuration with Web Console for detailed information and configuration instructions Disabled Mode You can disable any port on the CN2600 by setting the operation mode to Disabled 4 8 gt Configuration with the Web Console The web console is the most user friendly method available to configure the CN2600 With a standard web browser you have easy and intuitive access to all settings and options In this chapter we introduce the web console and go through the basic configuration options The same configuration options are also available through the Telnet and serial console The following topics are covered in this chapter O Using Your Web Browser gt Browser Cookie Settings gt Trusted Site Settings gt Opening the Web Console O Web Console Navigation 0 Basic Settings gt Server Settings gt Time Settings O Network Settings gt Basic Network Settings gt Advanced Network Settings gt Configuring the Route Table CN2600 Series Configuration with the Web Console Using Your Web Browser Browser Cookie Settings Verify that cookies are enabled for your browser If the cookies are disabled you will not b
20. COM mode After logging in as a super user enter the directory usr lib npreal2 driver and then execute mxaddsvr to map the serial port on the target terminal server to the host tty ports The syntax of the mxaddsvr command is as follows mxaddsvr Terminal Server IP Address Total Ports EData port Cmd port The mxaddsvr command performs the following actions l Modifies npreal2d cf 2 Creates tty ports in directory dev with major amp minor number configured in npreal2d cf 3 Restarts the driver 9 18 CN2600 Series Software I nstallation Configuration Mapping TTY Ports Automatically To map tty ports automatically you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 950 to 965 and command ports from 966 to 981 Mapping TTY Ports Manually To map tty ports manually you may execute mxaddsvr and manually specify the data and command ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 4001 966 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 4001 to 4016 and command ports from 966 to 981 Redundant COM Mode Before mapping the tty ports you must set the operation mode of your NPORT to Redundant COM Mode for npreal2 1 17 Build 1101
21. Client Server Architecture 0 Setting up the CN2600 gt Setting up the RADIUS Server IP Address gt Serial Port Configuration Setting up UNIX Hosts Setting up Windows NT Hosts Setting up Windows 2000 Hosts Setting up Windows 2003 Hosts 0000 CN2600 Series RADIUS Server What is RADIUS Definition Remote Authentication Dial up User Service or RADIUS is the standard for centralizing the authentication authorization and accounting of remote access users Here is a brief description of how RADIUS works When a user dials in to a remote access device that device communicates with the central RADIUS server to determine if the user is authorized to connect to the LAN The RADIUS server performs the authentication and responds with the result either accept or reject If the user is accepted the remote access server routes the user onto the network if not the server will terminate the user s connection The RADIUS server also provides accounting services if supported by the remote access server With RADIUS a network manager or ISP only needs to maintain a single central database against which all remote user authentications take place This greatly eases the management burden associated with administering a large number of dial in users Client Server Architecture RADIUS is a type of client server software Communication servers such as the CN2600 play an active role whereas RADIUS servers are passive When a remote host is
22. E v E C e EE E318 A 6 RAS 8PM to Male DBZ eise bene ina dado on neon orae one one nb oso o on ee oa orc road A 7 Serial Cables 2 Wire RS 485 A a A E DARA R A aa A 7 RIAS COA OS tO Female DES oom oda rad ead dad quc aded dad a dudit A 7 RJ 4533 105 Xo Male DEI spas BAUER ARABI IATER dd dedi A RR iilo in d AR DRIN RR A 7 RI A5 fospis o Female DB25 mman tr eur GE GERE C SA AT RE NONE OMA E RT A 7 RIA5 8 pins to Male DB25 vcre EE eee eae EVE ECCE CE a i i ee A 8 Pir Assignments Tor DBS and DB25 Connect Sutil alaba sobs eta yobs bebe atu eg rats titio A 8 Pin Assignments for DBO Male and Female Connectors ssssssssessse een nnn A 8 Pin Assignments for DB25 Male and Female Connectors esses nnns A 8 B SNMP Agent WII A a dba B 1 C DYNAMIC Domain Name SeVeiiiicacccncdc asa C 1 A C C 1 CODBgUr GEO meme O EN C 2 D Wel Known Port NUmbDeFrs A a A AE D 1 E RADIUS Server cia AAA E 1 Wat IS RADIOS anote joidede E 2 Bde paraa E 2 Client Server cArchitectilf A a E EE PED ME E E 2 setuno Up the CN2Z600 DUE E 3 Setting up the RADIUS Server IP AdCreSS ccccccccc cece eee eee eee eese msan ed DEE aa anna anna nnn E 3 Serial POMC ONTMGUEALOIN atada debe ean eee teas eau dues dada tebe ieee ed eaa dae deen dada teas iene leer teas eae een valet E 3 A NER NM ED DD DN D pave uw bey NN DN N E 3 SEO UD WINdGOWS NT EE TEE TEC E 4 seteng up WINGOWwWS 2000 HOSES science ta rile Ro ino Na ANA v
23. Ethernet SSL Certifica e pm HE Certificate Key Delete E System Monitoring E Save Configuration Certificate Key Delete Total Solution for Industrial Device Networkin CX Main Menu LC Overview Basic Settings Certificate Key Delete SSL certificate Delete Keep Network Settings 3 Serial Port Settings EHES System Management _ Submit EHE Misc Network Settings EH Auto Warning Settings EHE Maintenance System Monitoring Serial to Network Connections Go to Serial to Network Connections under Serial Status to view the operation mode and status of each connection for each serial port All monitor functions will refresh automatically every 5 seconds Total Solution for Industrial Device Networking Y Main Menu Serial to Network Connections a Overview ram Basic Settings v Auto refresh EI Network Settings Port OP Mode Connections Bg Serial Port Settings i m i al Device Control RealCOM HA System Management EX System Monitoring 2 Device Control RealCOM EC Serial Status Nba Jean Wk Wy Wil 1 il JL EIE JL TIE WAI 1I JI s WAT Ne Le Wl a cara to MBEWEHEEL 3 Device Control RealCOM lI 5 TE A Serial Port Status 4 Device Control RealCOM 1I Vt t ra Serial Port Error CoL g Serial Port Settings 5 Device Control RealCOM m 1I yj E HM System Status IH Ii 1 EE J EE Fm Save Configuration B Device GonHelifsdal c oM 1 fI JL EIE J
24. Mail Trap CQ SNMP Trap Port 8 O mail rrap C mail O Trap 9 Maintenance All ports O Mail O Trap O Mail Trap Certificate 3 System Monitoring 1 Save Configuration Restart On the Serial Event Settings page you may configure how administrators are notified of each serial port s DCD and DSR changes Mail refers to sending an e mail to a specific address Trap refers to sending an SNMP Trap DCD changed A change in the DCD Data Carrier Detect signal indicates that the modem connection status has changed For example if the DCD signal changes to low it indicates that the connection line is down When the DCD signal changes to low the CN2600 will automatically send a warning to the administrator as configured on the Serial Event Settings page DSR changed A change in the DSR Data Set Ready signal indicates that the data communication equipment is powered off For example if the DSR signal changes to low it indicates that the data communication equipment is powered down When the DSR signal changes to low the CN2600 will automatically send a warning to the administrator as configured on the Serial Event Settings page 8 7 CN2600 Series System Management Settings ATTENTION SNMP indicates a change in DCD or DSR signals but does not differentiate between the two A change in either signal from to is indicated by link up and a change in either signal from to is indicated by
25. RFC2217 Mode Total Solution for Industrial Device Networking CX Main Menu CJ Overview CJ Basic Settings 43 Network Settings Operation Modes Port 1 1 Application Device Control v A Serial Port Settings pp cm 33 Port 1 Mode RFC2217 CJ Operation Modes TCP alive check time 7 0 99 min A Communication P TCP port 4001 2 Data Buffering Lo C3 Modem Settings Data Packing 3 Packet length o X to 1024 m Port 2 E Port 3 Delimiter 1 00 Hex Denable HG Port 4 Delimiter 2 00 Hex C Enable cg Ports Delimiter process Do Nothing v Processed only when Packing length is 0 9 Port 6 Force transmit 0 0 65535 ms EG Port 7 ra or P1 Or2 Ors Or4 Ors P6 Or OPs H Ports Apply the above settings to Dall ports Y Welcome Message 3 System Management 3 System Monitoring 2 Save Configuration H Restart a v lt gt TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after clos
26. SENS ias 8 7 E E MM T E ata eageneduuedercetenety sents 8 8 i PI ea io O 8 9 Mal tenacidad 8 9 GONSOleS CTU PPP0O0NEEOPEPBenn o o beeen 8 9 xigroner ep 8 10 PRP A WN Wea SAD GT ad Sc aaa aot Gate aaa cet ta at ee 5550115005505 Sem ea aaa aetna e 8 10 Conhguratircdmbokt ExXDOFE ios 8 11 Edad Factory DetrquilS 250 dendi aio ae e e a o e o ten 8 12 Chande PSSS WO li ERE M MUR M UM A AM UM DUM M t IUE 8 12 G guis i H D EE 8 13 Ethernet SSL Certifticale IMD ut uda da aaa de oda a 8 13 cercate Key Delete ida dd ada ada traida T4328 A dq qva dra idad adulta dada 1E Ta died E 8 13 SVS COMIC MON AG RE RETTULIT 8 13 Serial to NetWork CONMECHIONS sesssssubusa rea ire rua a is ro fere st ve oa so e rua ro fe epu set pu oe safe euntes 8 13 Sena lPROrE a CAC RR ETT M 8 14 Serial iPort Error GCOUIlE on o ene n En Uode fades dada dom dada dade fadadade cta dadadoc dada ade fudiadada dida dad tds EUREN E 8 14 wi ariueguelcimildje f m T 8 14 Network ConnhecLtiofis 552 p RR e ERR ERR RE Rene GR e O 8 15 NEEWONK SCAS LCS Ru NON NUN NON NM M o ve rales babe ves bane been eLo os 8 15 S151 M icc Eos ETAT 8 16 System LOG Mr 8 16 ROUTING mE ee ae ie ker kir ee ie i es 8 17 Save CONTIGU ATION esoo tarot ates ea ema een TS 8 17 RSS A EE S E E EE T E E E E O E A E E E RT 8 18 Restart SYSTE ee ee O OOR 8 18 ROSAS O O 8 18 9 Soft
27. SNMP Agent with MIB II Simple Network Management Protocol agent software is built into the CN2600 The software supports cold warm start trap line up down trap and RFC 1213 MIB II The following table lists the standard MI B 1I groups as well as the variable implementations for the CN2600 Supported SNMP variables System MIB Interfaces MIB iPMIB ICMPMB wAdmnstmus iimDiscerds O lempin amp hos O fOpestus iinbelvers icmpinhoReps iasthane iOutequests lempinTimestamps WnOdes iOuiscar s temprimestampReps WmucasthHs ipoutNoRoutes tempinaddrMasks imNucestPks bRessmTimeou rempowtMsgs inbiscads iRessmeq s impOMEmors memos ipRessmKs IempOuDesUnradhs ifl nUnknownProtos ipReasmFails IcmpOutTimeExcds routers bfreSKs iempOuPamProbs fou cestPks fresals rempowtsreQuenchs fouN csstPs bfreCreaes lempOuRedreds roupas AdEMAdd tempos iAdEneasmMaxSue IcmpOuAddrMasks PL NeoMedlindex IcmpOutAddrMaskReps o wNeToMedaPhysAddress Pf mNemoMedaNetddress a quwemMedaype Pd ewmgpsemds CN2600 Series SNMP Agent with MIB II UDP MIB TCP MI B SNMP MI B FS eeAtempals swmpimosuchNames FS iConmemAddress smmpinGetResponses 0 tecomRemPot smmpifraps O es swpouodgs eeu swmpOuNoSuhNames O C smwOutBadvaues sms Sidi uetRequest
28. Save Configuration All ports Restart lt lt m 0 65535 ms P1 P2 L P3 P4 Ops L P6 Or Dre lt TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to O the TCP connection will remain open and will not send any keep alive packets Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Primary IP address The primary host s IP address If left blank then every host on the network cannot access the serial port Backup 1 IP address Backup host s IP address Backup 2 IP address Backup ho
29. Utility Once the program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation Setup NPort Search Utility Welcome to the NPort Search Utility Setup Wizard This will install HPort Search Utility S eri 1 en pour computer It is recommended that you close all other applications before continuing Click Nest to continue or Cancel to exit Setup 3 Click Next to install program files to the default directory or click Browse to select an alternate location 9 Setup NPort Search Utility Select Destination Location Where should MPart Search Utility be installed Fx e Setup will install NPort Search Utility into the following folder To continue click Nest IF you would like to select a different folder click Browse C Program FilessM Ports earch Browse Atleast 1 0 MB of free disk space is required lt Back EC CN2600 Series Software I nstallation Configuration 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder 9 Setup NPort Search Utility Select Start Menu Folder Where should Setup place the program s shortcuts A FU Setup will create the program s shortcuts in the following Start Menu folder To continue click Next IF uou would like ta select a different folder click Browse IIMPart Search Utility Browse Back Cancel 5 Click Next to proceed with the i
30. You may need to refer to your serial device s user s manual to determine the appropriate serial communication parameters Baud rate default 115200 bps This field configures the port s baudrate Select one of the standard baudrates from the dropdown box or select Other and then type the desired baudrate in the input box ATTENTION If the port requires a special baudrate that is not listed such as 500000 bps you may can select the Other option and enter the desired baudrate into the text box The CN2600 will automatically calculate the closest Supported baudrate The margin for error will be less than 1 7 for all baudrates under 921600 bps Data bits default 8 This field configures the data bits parameter Note If data bits is set to 5 bits stop bits will automatically be set to 2 bits Stop bits default 1 This field configures the stop bits parameter Note If data bits is set to 5 bits stop bits will automatically be set to 1 5 bits Parity default None This field configures the parity parameter Flow control default RTS CTS This field configures the flow control type FIFO default Enable This field enables or disables the 128 byte FIFO buffer The CN2600 provides FIFO buffers for each serial port for both the Tx and Rx signals Note however that you should disable the port s FIFO setting if the attached serial device does not have a FIFO buffer of its own This is because a Serial device
31. and Modem Settings Total Solution for Industrial Device Networking 3 Main Menu Operation Modes Lg Overview 2 Basic Settings i Port 1 9 Network Settings gt Applicati Device Cont v J Serial Port Settings MUN Acid tiles EM Port 1 Mode RealCOM wj a Operation Modes TCP alive check time 7 ko 99 min UC Communication P Max connection 1 1 Data Buffering Lo Ignore jammed IP Enable Disable d Modem Settings Allow driver control Enable Disable de punc _ Connection goes down RTS O always low always high C Port 3 DTR Oalways low always high wu as Data Packing bela Packet length 0 d SR acket len a 10 Port 6 g D 1024 aE Port7 Delimiter 1 DO Hex C Enable HH Port 8 Delimiter 2 00 Hex C Enable Welcome Message Delimiter process Do Nothing v Processed only when Packing length is 0 LQ System Management Force transmit D l ko 65535 ms ae ES O P1 Or Ors Om Ors Dr Oper Ope 9 Save Configuration Apply the above settings to CI All ports HH Restart m Y v a 4 Select Operation Modes in the navigation panel to select and configure the mode for each serial port For CN2600 models with 2 or more serial ports you may use the checkboxes at the bottom of the window to apply the settings to one or more ports Application Select an application for the serial port from among the choices Your application will determine t
32. characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP b
33. completed the hardware installation Note that the default IP address for the CN2600 is 192 168 127 254 NOTE After installing the hardware you must configure the operation mode of the serial port on your CN2600 to Real COM mode NOTE Only CN2600 2AC V4 2 firmware version 4 2 or later supports Redundant COM Mode I nstalling Linux Real TTY Driver Files Obtain the driver file from the included CD ROM or the MOXA website at http www moxa com Log in to the console as a super user root Execute cd to go to the root directory Copy the driver file npreal2xx tgz to the directory Execute tar xvfz npreal2xx tgz to extract all files into the system Se o Execute tmp moxa mxinst For RedHat AS ES WS and Fedora Corel append an extra argument as follows tmp moxa mxinst SP1 The shell script will install the driver files automatically 7 After installing the driver you will be able to see several files in the usr lib npreal2 driver folder gt mxaddsvr Add Server mapping tty port gt mxdelsvr Delete Server un mapping tty port gt mxloadsvr Reload Server gt mxmknod Create device node tty port gt mxrmnod Remove device node tty port gt mxuninst Remove tty port and driver files At this point you will be ready to map the terminal server serial port to the system tty port Mapping TTY Ports Real COM Mode Make sure to set the operation mode of the desired CN2600 serial port to Real
34. does not have an LCM Display panel and push buttons The LCM description below applies only to standard temperature models 3 2 CN2600 Series Initial IP Address Configuration ATTENTION If a password has been enabled for the CN2600 console and the LCM console is configured for writeable status the LCM console will require you to enter the password before allowing you access The password will not be required if the LCM console is configured for read only access The MENU button activates the main menu It is also used to cancel a selection and return to a previous menu The UP and DOWN buttons navigate between available options The SEL button confirms a selection or enters a submenu The IP environment Static DHCP PPPoE etc is configured under Main Menu gt Network setting gt IP config The IP address is configured under Main Menu gt Network setting gt IP address After the address has been entered you will need to restart the CN2600 under Main Menu gt Save Restart The following instructions explain how to set the CN2600 s IP address through the LCM console 1 Press MENU to activate the Main Menu The first line of the display indicates the current menu and should read Main Menu The second line indicates the current selection and should read Server setting Use the UP and DOWN buttons to select Network setting Press SEL to enter the Network setting menu 3 In the Network setting menu select IP config Don
35. driver only provides a pure data tunnel no control ability The serial port parameters will use firmware settings instead of depending on your application program AP Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send data back to the driver on the host Data will be sent first in first out when data comes into the CN2600 from the Ethernet interface ATTENTI ON When Max connection is greater than 1 the CN2600 will use a multi connection application i e 2 to 8 hosts are allowed access to the port at the same time When using a multi connection application the CN2600 will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted properly Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Allow driver control defaul
36. gt Restart Ports CN2600 Series System Management Settings Misc Network Settings Accessible IP List Total Solution for Industrial Device Networking Port 9 Port 10 Port 11 Port 12 Enable the accessible IP list Disable will allow all IP s connection request Accessible IP List Port 13 No Active IP Address Netmask Port 14 1 Port 15 Port 16 Welcome Message EX3 System Management EXA Misc Network Settings a Accessible IP List SNMP Agent DDNS Host Table Route Table User Table Authentication Server Oo 0 C t A t N a System Log Settings ao Auto Warning Settings Eg Maintenance E 73 Certificate He System Monitoring Qd Save Configuration H Restart nnmnmnumumunmnmnuuumumh The CN2600 uses an IP address based filtering method to control access to its serial ports The Accessible IP list allows you restrict network access to the CN2600 Access is controlled by IP address When the accessible IP list is enabled a host s IP address must be listed in order to have access to the CN2600 You may add a specific address or range of addresses by using a combination of IP address and netmask as follows To allow access to a specific I P address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and netmask use O for the last digit e g 192 168 1 0 and 255 255 2
37. ian ie hae ewe Chua t eat tar age dd bas hus kerikan iria 9 19 Removing Emux Driver FileS riisiin EENES 9 20 TRS UNI o RA DEVO raaa es 9 20 FS Cabin ENEN DIVE srn T C 9 20 contgurno tne UNIX DE T A 9 21 Modify the CONTA QUESO AAA AAA AA E 9 21 Boreal en 9 21 Starting MO o AAA 9 21 Adding an additional Servera a 9 21 A PINOUES and Cable WIFI Oct d n a n A A A iaa A 1 POrE PINOUT DIGORAINS in Os A 2 RS 232 422 485 Male DBO PINOUTS aa lidia asi A 2 RS 232 Male DB9 Pinouts uunrbr aereas A 2 Rsazazi Male Ras PINOUT ancla allioli a aA A 3 RS 232142 2485 Male RJ45 PIO QUES ancora rt Gra ood ot oe rano oa ados Got cuo c o ar AAA A 3 Cable WIRING DIagEeltTiS ertsia tiaan nie er MM ette ep SE put babe utut tutt eS EO eb uates A 4 8 Wah GOs 0 pm C n P A 4 Serial Cables RSSZ392 c5 ote eacu de m IA NE RR PRON ORC weet an dae ede PD eee ae MUN NM C DECOR A 4 RI45 t6 DIbs to Female DBOS5 n vorcsdtievir catania a ce cl Era c c rd ccr rc d Ca dc vl a v d A 4 RIAS tospinsiito Male DBI cistitis s A 5 RI d5 495pils O Female DB Zi A 5 Bo fee Sem coe tO Male DBA 2 illa A 5 Serial Cables RS 422 4 Wire RS 485 0 0 0 000ccccooccccnncnnn eee e eee e eee e me hne ha ahh haa hn hn A 6 iE 5 3201S 60 Female DO eT O O nO EEA E ENEON A 6 RIAS tsspiniSiito Male DBI id AAA rni it fa ita ra AS A 6 RASS ks to Female DB 2 dit a ada E
38. in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer w
39. is the IP address of the RADIUS server RADI US key This is the password that is used to access the RADIUS server IUS server UDP port This is the RADIUS server s assigned UDP port RADIUS accounting This field enables or disables RADIUS accounting Serial Port Configuration RADIUS is an effective authentication method for dial up services In addition to dial up services PPP SLIP and Dynamic the CN2600 supports RADIUS settings for terminal applications and console management application You will see it as an option for Authentication type when configuring the port s operation mode Please refer to Chapter 7 Configuring Serial Port Operation Mode for detailed information and configuration instructions Setting up UNI X Hosts MOXA recommends the FreeRADIUS server for UNIX users FreeRADIUS is the premiere open source RADIUS server and is one of the top five RADIUS servers in use world wide It is effective for both embedded systems with small amounts of memory and for systems with millions of users It is fast flexible and configurable and it supports more authentication protocols than many commercial servers The server is released under the GNU General Public License GPL which means that it is free to download and install FreeRADIUS can be downloaded from the following website http www freeradius com E 3 CN2600 Series RADIUS Server Setting up Windows NT Hosts 1 2 Install Windows NT OPTION PA
40. mail warning Network Event Ethernet1 and Ethernet2 refer to the built in Ethernet ports These settings configure the CN2600 to change the status of the relay output and alarm LED if the specified connection goes down Console web text login auth fail This field refers to a failed attempt to log in to a password protected CN2600 console I P changed With this option selected the CN2600 will attempt to send an e mail warning before it reboots after an IP address change However the CN2600 will reboot with the new IP address regardless of whether or not the e mail transmission is successful Password changed With this option selected the CN2600 will attempt to send an e mail warning before it reboots with a new console password If the CN2600 is unable to send an e mail message to the mail server within 15 seconds it will still reboot without sending the e mail Serial Event Settings Total Solution for Industrial Device Networking 3 Main Menu Cg Overview d Basic Settings Port Event Settings m i Serial Port Event DCD changed DSR changed S ee ERECET GE Port 2 O Mail DOTrap DO mail DO Trap HE Misc Network Settings POTS C mail OTrap O mail OTrap 23 Auto Warning Settings Port 4 Mail Trap C mail OTrap CJ Event Settings Port 5 O Mail Trap O Mail Trap Serial Event Setting Port 6 O Mail L Trap Cl mail Trap 3 E mail Alert Port 7 O Mail DOTrap O
41. name NP6000 DHCP Acknowledge My fully qualified domain Domain name moxa com name FODN is NP6000 moxa com DNS Server CN2600 Series 8 DHCP Action view Tree El te root 594qk nd Se Scope 192 Dynamic Domain Name Server Scope 192 168 20 0 DN moxa com tw Properties General UNS Advanced ou can set up the DHCP server to automatically update name and address Information on DNS servers that support dynamic updates v Automatically update DHCP client information in DNS Update DNS only if DHCP client requests Always update DNS Discard forward name to address lookups when lease expires onfigured in T CPZIP properties For Server OF Cancel Apply The above screenshot shows how DHCP can be set up to update the DNS Currently the CN2600 supports DNS service as provided by DynDNS For detailed information on this option please visit https www dyndns com Configuration Port 9 Port 10 Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 pH MARTTI i NACOXKA Welcome Message 23 System Management EXA Misc Network Settings pa rum ram B run rui ul T ta Accessible IP List SNMP Agent DDNS Host Table Route Table User Table Authentication Server System Log Settings E Auto Warning Settings E Maintenance E Certificate Eg System Monitoring QJ Save Configuration HG Restart DDNS
42. of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Allow driver control default No This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control commands will be accepted with the most recent command received taking precedence TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 Command port default 966 The Command port is the TCP port for listening to SSDK commands from the host In order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer w
43. servers can be placed in different branch offices and used as both multi point routers and as remote access servers When hosts e g the Web FTP and E mail News servers shown in the figure send requests to hosts on another network such as 202 6 6 xxx or 201 2 2 xxx the corresponding CN2600 delivers the request to the another CN2600 on the remote end 202 6 6 254 or 201 2 2 254 as the next hop router For this example assume that Modem 1 is connected to serial port 1 Modem 2 is connected to serial port 2 and PPP source and destination IP addresses of modems 1 2 3 and 4 are as follows 203 67 6 250 202 6 6 250 202 6 6 250 203 67 6 250 203 67 6 249 201 2 2 249 201 2 2 249 203 67 6 249 In this case you will need to add two entries to the routing table as shown in the following figure Total Solution for Industrial Device Networking CX Main Menu 5 Route Table Overview a SEke o No Gateway Destination Netmask Metric Iface H Network Settings E ___ de E E E EII a ee spa i 1 203 67 6 254 210 48 96 8 255 255 255 255 1 porti Y 1 Serial Port Settings t 23 System Management 2 EN 1i port2 23 Misc Network Settings 3 1 lani C Accessible IP List 4 1 lani CQ SNMP Agent s f lai E j DDNS i 6 1 lani C Host Table 5 CJ Route Ta
44. that does not have its own buffer may not be able to keep up with data sent from the CN2600 s FIFO buffer Interface default RS 232 You may configure the serial interface to RS 232 RS 422 RS 485 2 wire or RS 485 4 wire 7 2 CN2600 Series Additional Serial Port Settings Port Data Buffering Log X Main Menu s E Overview m Basic Settings HA Network Settings Eg Serial Port Settings BG Port 1 Operation Modes Data Buffering Log Port 1 Port buffering 128K Serial data logging 128K Apply the above settings to Total Solution for Industrial Device Networking O Enable 9 Disable O Enable Disable P1 P2 P3 Opa Ps Or6 P7 Ors DJ All ports Communication P 2 Modem Settings B Port 2 EJ Port 3 B Port 4 Bg Ports Bg Port 6 EJ Port 7 B Port 8 EM Welcome Message ai System Management eg System Monitoring re Save Configuration HE Restart lt i ve The CN2600 supports port buffering to prevent the loss of serial data when the Ethernet connection is down Port buffering can be used in TCP Server mode TCP Client mode and Pair Connection mode For other modes the port buffering settings will have no effect Port buffering enable default No You may enable port buffering by setting this field to Yes Serial data logging enable default No If this field is set to Yes the CN2600 will store data lo
45. this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port Redundant COM Total Solution for Industrial Device Networking CX Main Menu CJ Overview 2 Basic Settings Operation Modes z j Port 1 ig Network Settings l EX Serial Port Settings Applcspan Redundant COM Y 3 Port 1 Max connection 1v 3 Operation Modes Ignore jammed IP Enable Disable d Communication P Allow driver control Enable Disable CJ Data Buffering Lo Connection goes down RTS Oalways low 9 always high 2 Modem Settings DTR O always low 9 always high EM Port 2 Data Packing H d Packet length lo X K0 1024 T dbusu Delimiter 1 00 Hex C Enable Ports Bl Port 6 Delimiter 2 00 Hex C Enable 23 Port 7 Delimiter process Do Nothing Processed only when Packing length is 0 13 Ports Force transmit 0 ko 65535 ms UU Welcome Message pi Or Or Or Oms Ore Or Ops 3 System Management Apply the above settings to misc 3 System Monitoring A Save Configuration Restart lt Max connection default 1 This field is used if you need to receive data from different hosts simul
46. to simultaneously collect data from the same serial device ILE e RS 232 422 485 Device One of the major conveniences of using Real COM mode is that it allows you to use software that was written for pure serial communication applications The Real COM driver intercepts data sent to the host s COM port packs it into a TCP IP packet then redirects it through the host s Ethernet card At the other end of the connection the CN2600 accepts the Ethernet frame unpacks the TCP IP packet and then transparently sends the data through the serial port to the attached serial device 4 2 CN2600 Series Serial Port Operation Modes ATTENTION Real COM mode allows several hosts to have access control over the same CN2600 The drivers that come with your CN2600 control host access by checking the host s IP address Please refer to the Accessible IP List section in Chapter 8 System Management Settings for more details RFC2217 Mode RFC 2217 mode is similar to Real COM mode That is a driver is used to establish a transparent connection between a host computer and a serial device by mapping the serial port on the CN2600 to a local COM port on the host computer RFC2217 defines general COM port control options based on the Telnet protocol Third party drivers supporting RFC 2217 are widely available on the Internet and can be used to implement Virtual COM mapping to your CN2600 serial port s Socket Applications For socket ap
47. transmit ny ko 65535 ms cto P1 Or2 P3 P4 Ces OP6 Or OPs OJAll ports v lt 3E vi TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the 6 8 CN2600 Series Configuring Serial Port Operation Modes CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to O the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to O the TCP connection is kept active until a connection close request is received ATTENTION Inactivity time should at least be set larger than that of Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enou
48. ystem Monitoring 3 E d Serial Status 4 0 0 0 D C Serial to Network Cc 5 o QO D 0 ra Serial Port Status 6 0 0 0 E Serial Port Error CoL Li a B d J Serial Port Settings Go to Serial Port Settings under Serial Status to view a summary of the settings for each serial port Total Solution for Industrial Device Networking X Main Menu Serial Port Settings Cd Overview ram Basic Settings Wi Auto refresh HM Network Settings 3 3 Flow Control Bg Serial Port Settings Port Baud Rate Data Bits Stop Bits Parity RTS CTS XON XOFF DTR DSR FIFO Interface mc System Management 1 115200 8 1 Mone ON OFF OFF Enable RS 232 cp anion 2 115200 8 1 None ON OFF OFF Enable RS 232 dre Sle loi Suelo 3 115200 8 1 None ON OFF OFF Enable RS 232 CENA Serial Status 4 115200 8 1 None ON OFF OFF Enable RS 232 v Serialto Network Cc 5 115200 8 1 None ON OFF OFF Enable RS 232 imd senal Pare status 6 115200 8 1 None ON OFF OFF Enable RS 232 GS oin 7 115200 8 1 None ON OFF OFF Enable RS 232 i Serial Port Error CoL 8 115200 8 1 None ON OFF OFF Enable RS 232 i E Serial Port Settings i HYG System Status 8 14 CN2600 Series System Management Settings Network Connections Go to Network Connections under System Status to view network connection information 3 Total Solution for Industrial Device Networking HA Port 6 Network Connections E Port AQ Port 8 Protocol Recv Q Send Q Local Address Foreign Address State E
49. 0 Series Configuring Serial Port Operation Modes check time is set to O the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 min This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to O the TCP connection is kept active until a connection close request is received ATTENTION Inactivity time should at least be set larger than that of Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Auto Link Protocol If this field is set to None the CN2600 will not connect to the host automatically If Auto Link Protocol is set to Telnet or Rlogin the CN2600 will connect to the host automatically using the specified protocol Primary and Secondary host address If specified the fields designate permanent hosts to which the terminal will always be connected Telnet TCP port default 23 By default the Telnet TCP port number is set to 23 which is the default TCP port number for Telnet Terminal type default ansi Some older terminal applications may require that the terminal type be
50. 0 s i QU Network Settings memory To restart the server go to Restart System in the navigation panel ae Serial Port Settings ae System Management ao Misc Network Settings eum EC Auto Warning Settings ae Maintenance HG Certificate aa System Monitoring ae Serial Status Hi System Status ram Save Configuration 8 17 CN2600 Series System Management Settings Restart Restart System Go to Restart System under Restart and then click Restart to restart the CN2600 Ensure that you save all your configuration changes before you restart the system or else these changes will be lost Total Solution for Industrial Device Networking 3 Main Menu i Restart System re Overview ra Basic Settings eg Network Settings Eg Serial Port Settings Clicking Restart will disconnect all serial and Ethernet connections and reboot the La NPort 6000 server EN System Management Ree NOTE Unsaved configuration changes will be discarded and data currently in the EX Misc Network Settings middle of transmission may be lost H Auto Warning Settings ae Maintenance Roctat E Certificate EHES System Monitoring a Serial Status HG System Status fa Save Configuration E Restart am Restart System Y Restart Ports 1 Warning Restart Ports Go to Restart Ports under Restart and then select the ports to be restarted Click Select All to select all the ports Click Submit to restart the selected ports
51. 00 N o fF t Nee The Host Table may be used to simplify IP address entry on the CN2600 console by assigning a Host Name to a Host IP Address When you assign a Host Name to a Host IP Address you may then use the Host Name for some fields on the console rather than entering the IP address Up to 16 entries can be stored on the Host Table 8 4 CN2600 Series System Management Settings User Table an NPort Web Console Microsoft Internet Explorer Edit View Favorites Tools Help o y ix al ON JO Search 5 Favorites S ca E E Lg X Address http 192 168 127 254 oo Total Solution for Industrial Device Networking 83 Porto 83 Port 10 41 Port 11 EA Port 12 EJ Port 13 8j Port 14 B Port 15 E Port 16 gg Welcome Message User Table User Name Password Phone Number zZ o Eg System Management 2a Misc Network Settings e QJ Accessible IP List CJ SNMP Agent 3 DDNS ra Host Table ra Route Table ra User Table ra Authentication Server Eg System Log Settings a Auto Warning Settings ae Maintenance Certificate ne System Monitoring m Save Configuration HA Restart oO C s Cc 0d fF C N e mm o The CN2600 User Table may be used for to authenticate users for terminal or reverse terminal access and is useful if you do not have an external RADIUS server for authentication The CN2600 User Table stores up to 64 entries with fields for User Name Password and Phone
52. 1413 tgz or later only The following is a new command for mapping tty ports to Redundant COM Mode Mapping TTY Ports mxaddsvr r NPort IP1 Address NPort IP2 Address Total Ports Example cd usr lib npreal2 driver mxaddsvr r 192 168 32 134 192 168 126 123 16 In this example 16 tty ports will be added all with IP1192 168 32 134 and I P2 192 168 32 126 but with data ports equal to 950 951 965 and command ports equal to 966 967 968 981 Removing Mapped TTY Ports There are two ways to remove mapped tty ports 1 Remove mapped tty ports automatically after logging in as root enter the directory usr lib npreal2 driver and then execute mxdelsvr to delete a server The syntax of mxdelsvr is mxdelsvr IP For Real COM mode mxdelsvr I P1 For Redundant COM mode Example cd usr lib npreal2 driver mxdelsvr 192 168 3 4 If you do not include the I P address in the command line a numbered list of IP addresses for servers currently installed along with the total number of ports for each server will be listed on the screen 9 19 CN2600 Series Software I nstallation Configuration To remove the tty ports for a particular server type the number next to the server s IP address and then hit Enter The following tasks will be performed Modify the npreal2d cf Remove the relevant tty ports in directory dev Stop and then restart the driver Re
53. 1r 2 MB Detaile Space available on disk 1314 3 MB B lt Back Cancel Help 3 Select Details and then select Internet Authentication Service Continue clicking OK until the installation is complete Networking Services x To add ar remove a component click the check box 4 shaded box means that only part of the component will be installed To see what s included in a component click Details Subcomponents of Networking Services a Domain Name System DNS a Dinamic Host Configuration Protocol DHCP Y E Intemet Auth entication Service DBMB gEIRPCoverHTTPProw DOMB a Simple TCP ZIP Services 0 0 MB O dal windows Internet Mame Service WINS 0 9 MB Description Enables authentication authorization and accounting of dial up and PH users amp 5 supports the RADIUS protocol Total disk space required 14 6 MB Details 1314 3 MB Space available on disk 4 After the installation is complete click Administrative Tools and run the Internet Authentication Service This will open the following window Internet Authentication Service File Action View Help e m e i2 0 9 Welcome to Internet Authentication Service Mew gt Use Internet Authentication Service 145 to authenticate authorize and account For dial up VPN wireless and Ethernet connections to your network You can also configure IAS to fo
54. 2 1 x SVR4 2 make svr42 9 20 CN2600 Series Software I nstallation Configuration Configuring the UNIX Driver Modify the configuration The configuration used by the moxattyd program is defined in the text file moxattyd cf which is in the same directory that contains the program moxattyd You may use vi or any text editor to modify the file as follows ttyp1 192 168 1 1 950 For more configuration information view the file moxattyd cf which contains detailed descriptions of the various configuration parameters NOTE The Device Name depends on the OS See the Device Naming Rule section in README TXT for more information To start the moxattyd daemon after system bootup add an entry into etc inittab with the tty name you configured in moxattyd cf as in the following example ts 2 respawn usr etc moxattyd moxattyd t 1 Device naming rule For UnixWare 7 UnixWare 2 1 x and SVR4 2 use pts n For all other UNIX operating systems use ttyp n Starting moxattyd Execute the command init q or reboot your UNIX operating system Adding an additional server 1 Modify the text file moxattyd cf to add an additional server The user can use vi or any text editor to modify the file For more configuration information look at the file moxattyd cf which contains detailed descriptions of the various configuration parameters 2 Find the process ID PID of the program moxattyd ps ef grep moxatty
55. 2 IP Address2 Status ae ees 00 90 E8 0E F4 0E 192 168 32 65 00 90 E8 0E F4 0F 192 168 34 65 jesse eem Windows Driver Manager Installing NPort Windows Driver Manager The NPort Windows Driver Manager can be used with CN2600 serial ports that are set to Real COM mode The Driver Manager manages the installation of drivers which allow you to map unused COM ports on your PC to serial ports on the CN2600 These drivers are designed for use with Windows 95 98 ME NT 2000 XP 2003 Vista When the drivers are installed and configured devices that are attached to serial ports on the CN2600 will be treated as if they were attached to your PC s own COM ports If you are using the older version named Async Server Windows 2000 XP 2003 driver please refer to Chapter 9 Setting up Hosts for installation information Note that you may also download the latest Windows Driver Manager from Moxa s website l Click the INSTALL COM Driver button in the CN2600 Installation CD auto run window to install NPort Windows Driver Manager Once the installation program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation 18 Setup NPort Windows Driver Manager dmi xj Welcome to the NPort Windows Driver Manager Setup Wizard This will install NPort Windows Driver Manager Ver1 2 on your computer It is recommended that you close all other applications before continuing Click Next to conti
56. 2600 User Table or a RADIUS server for identity verification purposes Please refer to the Misc Network Settings section in Chapter 8 System Management Settings for instructions on setting up the CN2600 User Table Reverse Telnet Reverse Telnet mode is widely used for device management in telecommunication control rooms The system waits for a host on the network to initiate a connection Since TCP Server mode does not assist with conversion of CR LF commands reverse terminal applications that require this conversion should use Reverse Telnet mode 4 7 CN2600 Series Serial Port Operation Modes Dial In Out Modes Web Server E mail Server TCP IP CN2600 uu EN l Series V Router Modem P A PPP SLIP PPP Dialout Dialin Dialin Internet Modem d A a YA UNIX Server PC Notebook The CN2600 provides dial in dial out access for ISPs and enterprises that need a remote access solution When a user at a remote site uses a PPP dial up connection to access the CN2600 the CN2600 plays the role of a dial up server but also ensures that the user has legal access to the network by verifying the user s identity with the CN2600 User Table or a RADIUS server Please refer to the Misc Network Settings section in Chapter 8 System Management Settings for instructions on setting up the CN2600 User Table The CN2600 supports PPP SLIP and Terminal modes for dial in dial out access Regardless of which operating
57. 55 0 To allow unrestricted access Deselect the Enable the accessible IP list option Refer to the following table for more configuration examples 192 168 0 0 255 255 0 0 192 168 1 0 255 255 255 128 192 168 1 128 255 255 255 128 8 2 CN2600 Series System Management Settings ATTENTION The Accessible IP List will not be used if you configure the serial port for DRDAS Real COM mode or DRDAS TCP Server mode In this case the Primary IP address three Backup IP addresses and filtering method from the DRDAS configuration will be used SNMP Agent Settings Total Solution for Industrial Device Networking Port 9 Port 10 Port 11 s A E Configuration Port 12 SNMP e C Di Port 13 Enable Disable Port 14 Read community string public Write community private Port 15 string private Port 16 Contact name welcome Message Location HA System Management Misc Network Settings SNMP agent version Myvi Mv2 lv v3 Accessible IP List Read only user name Read only SNMP Agent dy ad authentication mode c Isable e DDNS Read only password Host Table Read only privacy Route Table mode SNMP Agent Settings l RR R DEBEEDDEDE A F FE E User Table Read only privacy Authentication Server Read write user name 000 E System Log Settings Read write HE Auto Warning Settings authentication mode Te M
58. A E P E E at Cian 6 22 PPPD MOG NAO aa 6 23 A orem c Xn 6 24 SIT PD NO asl aoa a nl as tte alata No EE Ea ante nats ae ate east elena eae E Eos aatia oes aet Suo 6 25 DYNAMIC MOGE M TTE 6 26 Disasted O O camo MIDI MTM UM M NN CMM I MM MM M KM MN M IM er ie et 6 26 7 Additional Serial Port SONO cae sors ian aie niece eee ann cee sees sien een oe ue esas aslo wae Suen A KUNDE EE 7 1 Port Communication Parameters uscumsiosscunnti iii 7 2 Se ldo shale tens EE ni sesasoner eros eee NOE NONIS 7 2 PortiData Bulteritid Lodi 7 3 Port Moden Set dudo late dada dola todoo E a E iio icdcdo s 7 3 WelcomeMess ade bbs ce leat 7 4 8 System Management SettingS amis aa 8 1 MISC NCTWORK SOLBIIdS e eis coti onto fon don ord cef orent pudor don fopra otiosi ctio ifo onde in iu 8 2 AC CCESSIDIE Mc HET 8 2 SNEP A O e A ER ERR ICI MEIIOMEPIEP E 8 3 Readsonly and Read Write access Control s eae Ret b RR be pe Nu RN tmd Gu b iu td Ei Ui a d 8 3 DISCE t c duda M MM MI MM M MI MM MA LUE 8 4 vf UEM 8 4 DE Ta Es do Scent NC NN MCN cA CN A DN E TN E NN DN NND TN n DI NC DN CD C D NEAN NN 8 5 PUTIN EICALIOM 25 CY Cl E E ET LS cce 8 5 System Log Settings riada ic c siS 8 6 io les 0 AAA 8 6 EVENUSELLINGS M a eere eere e eee e eee e eee enik ere enir eene 8 6 Seral Event S
59. Bg Porti BG Port 2 BJ Port 3 83 Port4 EJ Ports eg Port 6 83 Port 7 83 Porte c Welcome Message egg System Management eg System Monitoring m Save Configuration HE Restart Welcome Message Welcome Message Message You can enable and enter a welcome message to greet dial in or terminal users For ports configured for other modes the welcome message will not apply 7 4 8 System Management Settings In this chapter we describe additional server settings on the CN2600 The same configuration options are also available through the telnet and serial console The following topics are covered in this chapter O Misc Network Settings V Y VW ON Y Accessible IP List SNMP Agent Settings DDNS Host Table User Table Authentication Server System Log Settings O Auto Warning Settings Event Settings Serial Event Settings E mail Alert SNMP Trap O Maintenance Y Y NV ON ON WV Console Setting Ping Firmware Upgrade Configurating Import Export Load Factory Defaults Change Password O Certificate Ethernet SSL Certificate mport Certificate Key Delete O System Monitoring Y yY ON VV VV ON WV Serial to Network Connections Serial Port Status Serial Port Error Count Serial Port Settings Network Connections Network Statistics Serial Data Log System Log Routing O Save Configuration O Restart gt Restart System
60. CI Port 9 TCP 0 O 192 168 127 254 8000 LISTEN BC3 Port 10 TCP O 0 192 158 127 254 4900 E LISTEN ae TCP n O 192 158 127 254 14900 LISTEN EE TCP 0 D 192 168 127 254 80 LISTEN Ef Port 12 TCP 0 D 192 168 127 254 443 LISTEN EME Port 13 TCP 0 19246812725423 LISTEN O ta TCP 0 d 192 168 127 254 22 LISTEN mp oie TCP O O 192 168 127 254 950 LISTEN P TCP 0 O 192 168 127 254 951 LISTEN Ei Port 16 TCP 0 0 192 168 127 254 952 LISTEN Qd Welcome Message TCP O 192188127254 0583 LISTEN E System Management TCP n O 192468 127 254 054 LISTEN Eq System Monitoring TCP n O 192 158 127 254 055 E LISTEN ee eae TCP n 0 192 168 127 254 956 LISTEN E TCP O O 192 168 127 254 957 LISTEN EXSY System Status TCP n O 192 168127 254 858 LISTEN M J Network Connecti TCP 0 192 168 127 254 959 LISTEN TE EE TOP p f 18924R68 31 27 254 n6n TATEM Network Statistics Go to Network Statistics under System Status to view network statistics Total Solution for Industrial Device Networking a pore g Network Statistics E Port E Part 8 ETHERNET Received 235 Sent 321 a a ad i i Errsum O ER E BJ Port 10 x Received 226 Sent 310 PB PO Qi Port 11 IP RDiscard 0 SNoRoute SDiscard 0 EQ Port 12 ErrHeader 0 ErrProto n ErrAddr 0 EN Part 13 Received D Sent 0 2 EC Port 14 ICMP a 0 e 0 e REcnoR D SEcnorR H Port 15 RUNS ply EE UDP Received 32 Sent g
61. CK 4 0 on the Windows NT server Open Start gt Programs gt Windows NT 4 0 Option Pack gt Microsoft I nternet I nformation Server gt Management Console Manger Ti Programs Accessories Internet Explorer x Favorites NPort Server Pro Startup CS Documents gt EBooks Online BS Command Prompt Eh Settings QJ Windows NT Explorer CN E 7 amp Administrative Tools Common x J amp HyperSnap DX e Help Dmm a 7 i i Midas A internet Connection Services for RAS gt Run service Manager fS Microsoft Internet Information Server gt rmm NNTP um 48 Microsoft Transaction Server fc Microsoft SMTP Service d Product Documentation Internet Service Manager HTML Release Notes S windows NT 4 0 Option Pack Setup 2 Log Off Administrator hy Shut Down Go to Console Root gt Internet Information Server in the left pane Your computer s name should be Windows NT Server visible Find your computer s name in the left panel and click on it after which you will see RADIUS in the right information window n Microsoft Management Console iis Console Root nternet Information Server rats Ma ES T Console Window Help l x 3 Console Root E bob Ite met iore Server E 7 Administration Web Site 288 Default SMTP Site amp E Default NNTP Site H E Microsoft Transaction Server Right click RADIUS in the left information window and
62. CN2600 Series Dual LAN Terminal Server User s Manual Seventh Edition January 2013 WWW moxa com pr t O 2013 Moxa Inc All rights reserved CN2600 Series Dual LAN Terminal Server User s Manual CN2600 Series Dual LAN Terminal Server User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2013 Moxa Inc Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorpo
63. COM TTY driver that transmits all serial signals intact This enables you to preserve your existing COM TTY based software without needing to invest in additional software Three different socket modes are available TCP Server TCP Client and UDP Server Client The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verification making it possible to offer faster delivery UDP also allows unicast or multi unicast of data to one IP or groups of IP addresses The CN2600 also supports console management applications including Reverse Telnet modes Reverse terminal modes enable you to connect to a server s console port through an IP network for remote control and or monitoring of that server Device Control Applications For device control applications the CN2600 offers the following modes Real COM and RFC2217 mode Real COM Mode The CN2600 comes bundled with Real COM drivers for E Windows 98 ME NT 2000 XP 2003 Vista systems and TTY COM3 IP Port drivers for Linux systems BE TCP IP Ethernet In Real COM mode the bundled drivers are able to establish a transparent connection between a host and a serial device by mapping the serial port on the CN2600 to a local COM TTY port on the host computer Real COM mode supports up to 8 simultaneous connections that enable multiple hosts
64. CP BOOTP PPPoE Get IP Renew NTP Mail Fail NTP Connect Fail IP Conflict Network Link Down Sd Misc Network Settings C Accessible IP List Config O Login Fail IP Changed Password Changed Config Changed Firmware Upgrade SSL Certificate Import Config Import Config Export CJ SNMP Agent C3 DDNS OpMode Connect Disconnect Authentication Fail Restart CJ Host Table CJ Route Table User Table Submit CJ Authentication Serve QJ System Log Settings 41 Auto Warning Settings 1 3 Maintenance 0 Certficate 3 System Monitoring QJ Save Configuration a Restart System Log Settings allows the administrator to customize which network events are logged by the CN2600 Events are grouped into four categories known as event groups and the administrator selects which groups to log under Local Log The actual system events that would be logged for each system group are listed under summary For example if System was enabled then System Cold Start events and Power Down events for 2AC model would be logged System System Cold Start System Warm Start Power Down Network DHCP BOOTP PPPoE Get IP Renew NTP Mail Fail NTP Connect Fail DHCP Fail IP Conflict Ethernet Link Down Config Login Fail IP Changed Password Changed Config Changed Firmware Upgrade SSL Key Import Config Import Config Export OpMode Connect Disconnect Authentication Fail Restart Auto Warning Settings Event Settings Total Solution for Indust
65. Configuration DDNS Server address Host name Username Password Total Solution for Industrial Device Networking C Enable Disable DynDns org y DDNS default Disable Use this field to enable or disable DDNS Server address default DynDns org Currently DynDns org is the only option available for Server address Host name In this field use the name that you created on www dyndns com The CN2600 will update the DynDNS server with this host name Username This is the user name used for update authentication Password This is the password used for update authentication C 2 D Well Known Port Numbers In this appendix we provide a list of well Known port numbers that may cause network problems if you set the CN2600 to one of these ports Refer to RFC 1700 for well Known port numbers or to the following introduction from the IANA The port numbers are divided into three ranges the Well Known Ports the Registered Ports and the Dynamic and or Private Ports The Well Known Ports range from O through 1023 The Registered Ports range from 1024 through 49151 The Dynamic and or Private Ports range from 49152 through 65535 The Well Known Ports are assigned by the IANA and on most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the listed well known port numbers For more details please visit the IANA websit
66. E Era Port 15 ErrHeader 0 ErrPorts 0 lj Welcome Message Received 169 Sent 299 Eg System Management TCP ErrHeader 0 ErrPorts 0 Resent E CurrEstab 1 Opens 10 ES System Monitoring EC Serial Status ENS system Status 8 Network Connect CJ Network Statistics i Serial Data Log 8 15 CN2600 Series System Management Settings Serial Data Log Data logs for each serial port can be viewed in ASCII or HEX format After selecting the serial port and format you may click Select all to select the entire log if you wish to copy and paste the contents into a text file Total Solution for Industrial Device Networking B Porte Serial Data Log BG Port 7 83 Porte Data Log ASCII Eg Porto a Select port Porti y ASCIT HEX E Port 10 P e Port 11 j Port 12 EC Port 13 E Port 14 j Port 15 EC Port 16 Welcome Messag Eier System Managemer EB System Monitoring Ela Serial Status ES System Status a Network Connt G Network Statis rl CJ Serial Data Loc 1 System Log Select all Clear log Refresh A mS System Log This option displays the system log You may click Select all to select the entire log if you wish to copy and paste the contents into a text file Total Solution for Industrial Device Networking E Porte 56 Port 7 He Port 8 System Log B Ports CJ Port 10 8 Port 11 BJ Port 12 amp C3 Port 13 BL Port 14 amp Port 15
67. Eront gla ee eee 3 2 ARP eee oe ee eee ee er ne eC RC ne ee en me mn Ee ome ee me mn nme MM os 3 3 lea ee een eee ene tne T 3 4 4 e REO q 10 AE e Po II O E 3 7 Serial Port Operation ModesS comicos esse swnnewsasssnnesesesenwneewdesennadeeadanins 4 1 OVE IC Wear caca 4 2 Device Control AD DIICATIONS camita 4 2 aire Nl cu ti aa 4 2 REC2Z2Z 17 om UMS 4 3 SOC ECAD ION CONDE aia 4 3 TEP o AEO O ETT 4 3 A a Tn ee ee eer 4 3 MESS PSN CN A cana A o 4 4 Redundant CON EM a ee nn er Em 4 4 Dual host Redundant Data Acquisition System DRDAS cccccc cece cece eee essen nnns 4 5 Ferminak Applications menre r r T E 4 6 Terminal AS Cl PMO E ada ao 4 6 Ei A ni 4 6 Reverse TE MINA A o 4 7 Reverse el 4 7 Dial ity Our MOJE S sius sace d det idu dieta MM t d MM EE MAE MM MM M EE 4 8 Disabled Mode ect tinas te Att Mm A MM MTM UM MM calada 4 8 Configuration with the Web Console seereeeeeseeee naa hnnnn enu a han nnnuuuua nnne ua auae u auae 5 1 Using YoUr WED BIOWSCR PDT m 5 2 a PP en ee nt 5 2 TS Da 5 3 Opening the Web COlsole s e eel el el et ed el bel su LIC el dee aa 5 4 Web Cohsole Navigator s tana On 5 5 BaSiG S CULING ft E TERRORIST 5 5 seners HH 5 5 a c m a O o O 5 5 Er SetHlHds ON 5 6 Basic Networks OTS dasotl tdi da tada tica da adora HUMUM alada duela da la MM M MM MSIE 5 6 Advanced NetWork Settings sodas Mebut
68. L ELE Eg Restart TREE Wall T esta 7 Device Control RealCOM ET 1f TEIL WAL WUT IAT 8 Device Control RealCOM n Ti T 8 13 CN2600 Series System Management Settings Serial Port Status Go to Serial Port Status under Serial Status to view the current status of each serial port Serial Port Status gt Buffering Total Solution for Industrial Device Networking S Main Menu Serial Port Status UC Overview ram Basic Settings v amp uto refresh eg Network Settings Port TxCnt RxCnt TxTotalCnt RxTotalCnt DSR EDIRS PRESO CTS DGD Buffering 9 Serial Port Settings 1 D o Y d O d d o ae System Management o o 0 0 gt gt 9 gt gt D E ea System Monitoring l n 5 gt gt gt gt ENS Serial Status 5 0 0 0 0 9 o gt gt 0 Serial to Network Cc 6 o o o 0 9 d J 0 Serial Port Status d 0 0 0 o Y d E 2 J 0 8 o o o o 9 gt E gt gt 0 CJ Serial Port Error Cou E Serial Port Settings Monitor port buffering usage bytes of each serial port Serial Port Error Count Go to Serial Port Error Count under Serial Status to view the error count for each serial port Total Solution for Industrial Device Networking SY Main Menu Serial Port Error Gount Od Overview a Basic Settings v Auto refresh H Network Settings Baw ErrCnt ae Serial Port Settings M Frame Parity Overrun Break HG System Management 1 0 0 0 0 Bey Syst Monitori 2 D D 0 0 UA
69. Ld To import a configuration go to System Management gt Maintenance gt Configuration I mport Enter the configuration file path name and click Submit The CN2600 s configuration settings will be updated according to the configuration file If you also wish to import the IP configuration i e the CN2600 s IP address netmask gateway etc make sure that I mport all configurations including IP configurations is checked off Total Solution for Industrial Device Networking 2 Main Menu ra Overview ram Basic Settings egg Network Settings egg Serial Port Settings EN System Management Download eg Misc Network Settings eg Auto Warning Settings ES Maintenance ram Console Settings ram Firmware Upgrade Configuration Export Configuration Export Gu Configuration Import Gu Configuration Export ram Load Factory Default 33 Change Password 4 Certificate egg System Monitoring To export a configuration go to System Management gt Maintenance gt Configuration Export and click Download A standard download window will appear and you will be able to download the configuration into a file name and location of your choice 8 11 CN2600 Series System Management Settings Load Factory Defaults Main Menu 2 Overview C3 Basic Settings HC Network Settings 9 Serial Port Settings ES System Management ae Misc Network Settings ae Auto Warning Settings 53 Main
70. N2600 Series Serial Port Operation Modes Reverse Terminal Applications Unix Windows NT TCP IP CN2600 Series joujaL Router Server Server Reverse terminal applications are similar to terminal applications in that they involve using the CN2600 to manage the connection between a terminal and a server The difference is that with reverse terminal applications the terminal is connected through the network and the server is connected through the serial port rather than the other way around In practice a reverse terminal session typically involves a network administrator telnetting to a device that has a dedicated serial console port used specifically for configuration purposes For example many routers switches UPS units and other devices including the CN2600 have Console AUX or COM ports to which a terminal can be physically connected for console management With the CN2600 the device s console port can be connected to a serial port on the CN2600 allowing a network administrator to telnet to the device remotely through the network Although modern network equipment generally allows other options for remote configuration through the network there are situations in which it is necessary or desirable to configure a device by serial console e g for security reasons when using older generation equipment or as a backup configuration method when the network is down CN2600 reverse terminal modes allow the use of the CN
71. Number Authentication Server 3 NPort Web Console Microsoft Internet Explorer File Edit View Favorites Tools Help sek x ix al A j Search f Favorites E LJ 3 OE O 15 x Total Solution for Industrial Device Networking Bg Porto E ur ney Port 10 Authentication Server um LE Configuration Hg Port 12 B3 Port 13 RADIUS server IP SY Bs Port 14 RADIUS key rT B Port 15 UDP port 1645 y Bg Port 16 RADIUS accounting C Enable Disable g Welcome Message SUN System Management Ta Misc Network Settings d Accessible IP List C3 SNMP Agent C3 DDNS uu Host Table Gu Route Table Gu User Table ram Authentication Server 33 System Log Settings a Auto Warning Settings RADI US server IP If you are using a RADIUS server for user authentication enter its IP address here 8 5 CN2600 Series System Management Settings RADI US key If you are using a RADIUS server for user authentication enter its password here UDP port default 1645 If you are using a RADIUS server enter its UDP port assignment here RADIUS accounting Use this field to enable or disable RADIUS accounting System Log Settings Main Menu CJ Overview CJ Basic Settings BC Network Settings System Log Settings Event Group Local Log Summary 1 x System E System Cold Start System Warm Start Power Down Serial Port Settings im M il Fai i O nE Network O DH
72. P address will be reconfigured ATTENTION In order to use the ARP setup method both your computer and the CN2600 must be connected to the same LAN Alternatively you may use a cross over Ethernet cable to connect the CN2600 directly to your computer s Ethernet card Before executing the ARP command your CN2600 must be configured with the factory default IP address 192 168 127 254 and your computer and the CN2600 must be on the same subnet To use ARP to configure the IP address complete the following 9 Obtain a valid IP address for your CN2600 from your network administrator 10 Obtain your CN2600 s MAC address from the label on the bottom panel 3 3 CN2600 Series Initial IP Address Configuration 11 Execute the arp s command from your computer s MS DOS prompt as follows arp s IP address gt MAC address gt For example C gt arp s 192 168 200 100 00 90 E8 04 00 11 12 Next execute a special Telnet command by entering the following exactly telnet 192 168 200 100 6000 When you enter this command a Connect failed message will appear as shown below c Command Prompt AE D ix gt arp s 192 168 200 100 88 980 e8 62 580 89 D x gt telnet 192 168 200 100 6888 Connecting To 192 168 268 188 Could not open connection to the host on port 6 AAA Connect failed 13 After the CN2600 reboots its IP address will assigned to the new address and you can reconnect using Telnet to verify that the upda
73. Ports Outgoing PAP ID ud Port 6 PAP password La E LI E T iid Incoming PAP check None H Port8 f l Disconnect by None bal LJ Welcome Message MM P1 P2 L P3 L P4 Ces OP6 Or7 Ors Ho System Management Apply the above settings to CJ All ports 3 System Monitoring 2 Save Configuration Restart A gt A PPP provides standard PPP service for both dial in and dial out Destination IP address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port I P netmask The IP netmask defines the netmask also known as the subnet mask for the PPP connection TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Link quality report default No Setting this field to Yes allows the CN2600 to disconnect a connection if the link noise exceeds a certain threshold Outgoing PAP ID This is the dial out user ID account PAP password This is the dial out user password Incoming PAP check default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description Local Verify the ID against t
74. User name This field is for your mail server s user name if required Password This field is for your mail server s password if required From e mail address This is the e mail address from which automatic e mail warnings will be sent To e mail address 1 to 4 This is the e mail address or addresses to which the automatic e mail warnings will be sent 8 8 CN2600 Series System Management Settings SNMP Trap NPort Web Console Microsoft Internet Explorer OS Web Console Microsoft Internet NPort Web Console Microsoft Internet Explorer OS B x File Edit View Favorites Tools Help sack X M x E TN JO Search ST Favorites E S ca l a E L4 X anes O TEES Total Solution for Industrial Device Networking m PA RTN SNMP Trap QJ Overview T Basic Settings SNMP Trap 4 Network Settings ac Serial Port Settings SNMP trap receiver IP System Management Trap version y1 C y2c Eg Misc Network Settings Trap community public ES Auto Warning Settings Eg Event Settings Submit C Serial Event Settings ram E mail Alert EJ SNMP Trap Maintenance SNMP trap server IP Use this field to indicate the IP address to use for receiving SNMP traps Trap version default v2 Use this field to select the SNMP trap version Trap community default public Use this field to designate the SNMP trap community Maintenance Console Setting A NPort Web Console Microsoft Interne
75. aintenance Read write password CJ Certificate Read write privacy mode 7 c m und Pom 7 und gm und Pom e 7 c pa C Disable y System Monitoring i Read write privacy Save Configuration Restart ba Submit l SNMP To enable the SNMP Agent function select the Enable option and enter a community name e g public Read community string default public This is a text password mechanism that is used to weakly authenticate queries to agents of managed network devices Write community string default private This is a text password mechanism that is used to weakly authenticate changes to agents of managed network devices Contact name The optional SNMP contact information usually includes an emergency contact name and telephone or pager number Location Use this optional field to specify the location string for SNMP agents such as the CN2600 This string is usually set to the street address where the CN2600 is physically located SNMP agent version The CN2600 supports SNMP V1 V2 and V3 Read only and Read write access control The following fields allow you to define user names passwords and authentication parameters for two levels of access read only and read write The name of the field will indicate which level of access it refers to For example Read only authentication mode allows you to configure the authentication mode for read only access wherea
76. an advanced remote access server and click Next to continue B Routing and Remote Access la x A Im E E SE Aa Ce l ST Action Routing and Remote Access Server Setup Wizard Remote Access Server Setup You can use a basic configuration or more advanced options to set up this remote access server Select a configuration type based on the complexity of your network Setup a basic remote access server Select this option to create a standalone server that will have simplified administrative control Setup an advanced remote access server Select this option to create a server that will have advanced administrative Features such as remote access policies or if you plan to add this server to a domain amp Back Cancel Start e 5 Routing and Remote A KE 1 56 PM 5 Select TCP I P protocol then click Next to continue B Routing and Remote Access Action Ir lA e as lo Routing and Remote Access Server Setup Wizard Tree Remote Client Protocols Routing The protocols required Far remote client access must be available an this server Verify that the protocols required on this server for remote clients are listed below Protocols Yes all of the required protocols are on this list C No need to add protocols start e a Si Routing and Remote A Ee 2 01 PM 6 Specify your IP address as shown on the following screens amp Routing and Remote Acces
77. arch for CN2600 terminal servers From the list that is generated select the server that you will monitor and then click OK Searching MPart s Searching Found 1 MPort s remaming 4 seconds Hescan Select Ail Clear Al Model X MAC address 1 IPaddress1 M Caddress2 IP address2 CN2610 16 00 90 ES 0E F4D0E 192 168 324 188 UD SUEESUEFF4DF 132158 36 188 The monitoring information will appear on the Monitoring page Select the IP address from the left hand side that you would like to monitor and then click the Start icon E Monitor Miley Sinis idi Model CM ERIE IPadders P52 165032 MER 152 168 36 108 MAD Addere DAAA REE Pade GSE a OE FA OE 9 16 CN2600 Series Software I nstallation Configuration 5 The status will be listed as On Line which means that all of the port numbers with LAN 1 and LAN 2 IP addresses will appear on the page If your maximum connections is 2 the monitor s connection 2 will show the LAN IP address E Monitor Mile Sisa iha Lint Montel CHIOT E IP adden 158 158 32 188 182 168 36 1083 MAD Addorrr OD SEERDE FADE SPEAR OE FA DE Per paaxnbioie LAM Correct temen Cormeen Come 1 Fleurs COM LANI LANA Fiedurchani CH LAN LARG Fiedursbas COM Lak LAN la Fadura COM LANI LAK Fedeari COM unm LARG 6 Redurdara COM LAKI LAM Fisdurciss COM LAHI LAK Fiedurciant CH LANI LAN Fieduradara COM LANI LAN
78. ata can be transmitted in Proceed with A both directions between the host and the CN2600 data transmission RE 4 3 CN2600 Series Serial Port Operation Modes UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can unicast or multi unicast data A from a serial device to one or multiple host computers and the N gt Directly proceed with data transmission no connection required serial device can receive data from one or multiple host computers These traits make UDP mode especially suited for message display applications m nia RS 232 422 485 Device E gt Redundant COM LAN A Ethernet LAN B Data A Serial p RTU The Redundant COM operation mode can be used to set up a redundant LAN between the serial devices connected to the CN2600 s serial ports and the host computer The redundant structure involves using the CN2600 s two LAN ports to set up two independent LANs that connect the CN2600 to the host computer If either of the two LANs fails the other LAN will continue transmitting packets between the serial devices and the host with the packets passing through the CN2600 In fact one of the biggest advantages of the CN2600 s Redundant COM mode is that the switching time is zero ATTENTI ON If either LAN gets disconnected it will take at least 1 minute for the LAN to recover after reconnecting If both LANs get disconnected you will need
79. ble d l lanl WN Cg User Table 8 1 lani Y z CJ Authentication Serve 9 P lani System Log Settings 10 1 lani B T 2 s A TA Auto Warning Settings 11 1 lant Wi Maintenance Lp E 12 1 lani 13 Certificate 3 System Monitoring 13 d lani 3 Save Configuration 14 1 lani 0 Restart 15 1 lani 5 12 6 Configuring Serial Port Operation Modes In this chapter we explain how to configure the individual serial port modes The following topics are covered in this chapter O Port Setting Basics O Device Control Applications gt Real COM Mode gt RFC2217 Mode O Socket Applications gt TCP Server Mode gt TCP Client Mode gt UDP Mode O Redundant COM O DRDAS gt DRDAS Real COM gt DRDAS TCP Server O Terminal Applications gt Terminal ASCII TERM_ASC gt Terminal BIN TERM_BIN O Reverse Terminal O Dial In Out Applications PPP Mode PPPD Mode SLIP Mode SLIPD Mode Y Y ON V WV Dynamic Mode O Disabled Mode CN2600 Series Configuring Serial Port Operation Modes Port Setting Basics Each serial port on the CN2600 can be configured independently To configure the operation mode and settings for a port expand Serial Port Settings in the navigation panel then expand the port that you would like to configure Individual port settings are grouped into four categories in the navigation panel Operation Modes Communication Parameters Data Buffering Log
80. board and monitor that is used to configure settings and monitor the status of your system The console port can be used if a network is unavailable or you do not know the CN2600 s IP address To connect to the console port use a PC running UNIX or a PC with terminal emulation software e g HyperTerminal or PComm by Moxa parameter settings are baudrate 115200 bps parity check None data bits 8 stop bits 1 terminal type VT100 Use an RJ 45 to DB25 or RJ 45 to DB9 cable to connect the terminal to the console port 2 3 CN2600 Series Hardware Installation Adjustable Pull High Low Resistors for the RS 485 Port In some critical environments you may need to add termination resistors to prevent the reflection of serial signals When using termination resistors it is important to set the pull high low resistors correctly so that the electrical signal is not corrupted The CN2600 uses jumper settings or DIP switches to set the pull high low resistor values for each serial port To set the pull high low resistors to 150 KQ make sure both of the assigned DIP switches are in the OFF position This is the default setting To set the pull high low resistors to 1 KQ make sure both of the assigned DIP switches are in the ON position ATTENTION Do not use the 1 KQ setting on the CN2610 when using the RS 232 interface Doing so will degrade the RS 232 signals and shorten the maximum allowed communication distance 2 4
81. cable is disconnected Rear Panel Power Input 10 100 BaseT Ethernet Ports RJ45 Serial Ports RS 232 Console Port See Power Input 10 100 BaseT Ethernet Ports DB9 Serial Ports Emp eu ge RS 232 Console Port mm ras o gom lla Automatic detection of 100 240V 47 63 Hz AC power supply indicates power on O indicates power off AC models only 8 pin RJ 45 RS 232 port for console terminal connection 8 pin RJ 45 auto detectable 10 100 Mbps UTP port 8 pin RJ 45 auto detectable 10 100 Mbps UTP port 8 or 16 8 pin RJ 45 or DB9 ports for DCE modem type connections Ej lt gt lt a lt a 1 4 CN2600 Series Introduction Bottom Label The server s serial number and MAC address are printed on a label fixed to the bottom of the server The CN2600 has 2 LAN ports each with its own MAC address The MAC address is the unique hardware Ethernet address used to identify a network hardware product Write each of the two MAC addresses in the space provided below for future reference LAN 1 MAC address LAN 2 MAC address 1 5 2 Hardware Installation This chapter includes instructions on where and how to install the CN2600 dual LAN terminal server Both basic and advanced software configuration instructions are given The following topics are covered in this chapter Desktop Rackmount Wiring Requirements Connecting the CN2600 8 16 s Power Connecting to the Network Connec
82. connected to the CN2600 the host is prompted to enter a user ID and password After receiving the user ID and password the CN2600 sends the information to a defined RADIUS server Up to this point the remote user is still unable to access the network The RADIUS server compares the user ID and password with its internal database and responds through the network either accepting or rejecting the connection attempt If the CN2600 receives the accept message from the RADIUS server the remote user is allowed to access the network Otherwise the CN2600 will either terminate the connection or attempt to connect again after a specified duration of time E 2 CN2600 Series Setting up the CN2600 Setting up the RADI US Server IP Address RADI US Server Port 9 Port 10 Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 Welcome Message poe EE Ee BB EE EH 03 System Management ES Misc Network Settings Accessible IP List SNMP Agent DDNS Host Table Route Table User Table Authentication Server i System Log Settings 119 Auto Warning Settings 1 Maintenance Y Certificate System Monitoring a 3 Save Configuration QJ Restart Total Solution for Industrial Device Networking Authentication Server Configuration RADIUS server IP RADIUS key UDP port RADIUS accounting OT ee 1645 y C Enable Disable Submit RADIUS server IP This
83. d 3 Update configuration of moxattyd program kill USR1 PID e g if moxattyd PID 404 kill USR1 404 This completes the process of adding an additional server 9 21 A Pinouts and Cable Wiring The following topics are covered in this appendix O Port Pinout Diagrams gt RS 232 422 485 Male DB9 Pinouts gt RS 232 Male DB9 Pinouts gt RS 232 Male RJ45 Pinouts gt RS 232 422 485 Male RJ 45 Pinouts O Cable Wiring Diagrams Ethernet Cables Serial Cables RS 232 Serial Cables RS 422 4 Wire RS 485 Serial Cables 2 Wire RS 485 Pin Assignments for DB9 and DB25 Connectors V Y V WV CN2600 Series Port Pinout Diagrams RS 232 422 485 Male DB9 Pinouts 12345 RS 232 Male DB9 Pinouts 12345 Pinouts and Cable Wiring CN2600 Series Pinouts and Cable Wiring RS 232 Male RJ 45 Pinouts DSR in 2 GND 3 4 T5 so Cn ao omo RS 232 422 485 Male RJ 45 Pinouts RS 422 RS 485 2W RS 485 4W 1 sR AA TxD B GND CN2600 Series Pinouts and Cable Wiring Cable Wiring Diagrams Ethernet Cables Straight Through Cable RJ45 Plug Pin 1 Cable Wiring Fi Cross Over Cable ME Ti RJ45 Plug Pin 1 IE M amp M amp CO Cable Wiring 3 1 6 2 1 3 2 6 Serial Cables RS 232 RJ 45 8 pins to Female DB9 RJ45 Port RJ45 Connector Female DB9 Male DB9 EJ 3 RS 232 CN2600 Device 8 pins Cable Wiring 9 pins DSR 1 4
84. d baudrate For example assume that the serial port is set to 1200 bps 8 data bits l stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms 6 10 CN2600 Series Configuring Serial Port Operation Modes If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port UDP Mode Total Solution for Industrial Device Networking 3 Main Menu Operation Modes 4 CJ Overview 9 Basic Settings Port 1 E Network Settings Application Socket Ly HE Serial Port Settings Mod UDP J y wi Porti Destination address 1 Begin i End Port 4001 LJ Operation Modes mM z Put Destination address 2 Begin End Port 4001 J Communication P 5 nt Data Buffering Lo Destination address 3 Begin End Port 4001 Modem Settings Destination address 4 Begin End Port 4001 43 Port 2 Local listen port 4001 0 Port 3 Data Pack
85. d local time settings 5 5 CN2600 Series ATTENTION Configuration with the Web Console There is a risk of explosion if the real time clock battery is replaced with the wrong type The CN2600 s real time clock is powered by a lithium battery We strongly recommend that you do not attempt replacement of the lithium battery without help from a qualified Moxa support engineer If you need to change the battery please contact the Moxa RMA service team Time zone default GMT Greenwich Mean Time This field shows the currently selected time zone and allows you to select a different time zone Local time This field shows the time that you last opened or refreshed the browser To set the local time for the CN2600 click on the Modify button then submit your changes in the screen as shown below 3 Time Settings Modify time settings Date yy mm dd Time hh mm ss 2006 s Ro s fis fas Submit Close Time server The CN2600 uses SNTP RFC 1769 for auto time calibration You may enter a time server IP address or domain name in this optional field Once the CN2600 is configured with the correct time server address it will request time information from the time server every 10 minutes Network Settings Basic Network Settings MOXA Main Menu E CJ Overview CJ Basic Settings Network Settings Basic Network Settings 9 Advanced Network Set 3 Serial Port Settin
86. destination Netmask This is the destination network s netmask Metric Enter the number of hops from the source to the destinationto allow the CN2600 to prioritize the routing of data packets if more than one router is available Iface This is the network interface to which the packet must be sent ATTENTION When a serial port is configured for PPP SLIP the Iface field must be set to that serial port for proper communication 5 9 CN2600 Series Configuration with the Web Console Configuring Routes to the I nternet Ethernet 203 67 6 TCP IP ieee Router Series 203 67 6 254 Internet In this example the Notebook PC dials into the CN2600 to request a connection to the Internet host at 210 48 96 9 which is not on the local network 203 67 6 xxx This causes the CN2600 to act as a router and send the datagram to the default next hop router 203 67 6 254 In this case we should add the gateway IP address of 203 67 6 254 to the routing table to handle hops to 210 48 96 9 Total Solution for Industrial Device Networking 3 Main Menu amp E Route Table QJ Overview a E No Gateway Destination Netmask Metric Iface EC Network Settings i F y 1 203 67 6 254 210 48 96 9 255 255 255 255 1 lani HE Serial Port Settings 3 System Manageme
87. e Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for netw
88. e able to use the web console Cookies are only used for password transmission 1 For Internet Explorer enable cookies by selecting Internet Options from the Tools menu General Security Privacy Content Connections Programs Advanced r Home page LA You can change which page to use for your home page Address nfisapifredir dll prd iespyer 68 ar msnhome Use Current Use Default Use Blank M Temporary Internet files F Pages you view on the Internet are stored in a special folder for quick viewing later Delete Cookies Delete Files Settings M History The History folder contains links to pages you ve visited for 4 quick access to recently viewed pages Days to keep pages in history 20 ES Clear History Colors Fonts Languages Accessibility Cancel Apply 2 Select the Privacy tab There are six levels of privacy setting Block All Cookies High Medium High Medium Low and Accept All Cookies Users must select Medium High as the image shows or below to access the CN2600 web console General Security Privacy Content Connections Programs Advanced M Settings Move the slider to select a privacy setting for the Internet Lg zone A Medium High Blocks third party cookies that do not have a compact i privacy policy Blocks third party cookies that use personally identifiable i infor
89. e at http www iana org assignments port numbers TCP Socket Application Service Reserved TCP Port Service Multiplexer 1 9 Discard Time Time Server Network News Transfer Protocol NNTP aa w CN2600 Series Well Known Port Numbers UDP Socket Application Service o i Reevd SSCS eo CN Active Users systat Host name server names server Whois nickname 49 Login Host Protocol login Domain Name Server domain ENS Trivial Transfer Protocol TETP 80 World Wide Web HTTP 111 Sun Remote Procedure Call Sunrpc 119 Network News Transfer Protocol NNTP 123 Network Time Protocol NTP 161 SNMP Simple Network Mail Protocol 162 SNMP Traps 213 I PX used for IP Tunneling RADIUS Server Managing diverse serial lines and modem pools for large numbers of users creates the need for significant administrative support Since modem pools are links to the outside world careful attention must be paid to security authorization and accounting This can best be achieved by managing a single database of users allowing authentication verifying user names and passwords as well as configuration of information that details the type of service to deliver to the user e g SLIP PPP Telnet and rlogin The CN2600 supports the RADIUS protocol which requires only one database for remote user management The following topics are covered in this appendix O What is RADIUS gt Definition gt
90. e sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by
91. eck time 0 99 min 3 Communication P Inactivity time 0 0 65535 ms a Data Buffering Lo Max connection 1 v C Modem Settings Ignore jammed IP Enable Disable tud Port 2 Allow driver control Enable Disable BC Port 3 ES mu TCP port 4001 4 EJ Ports Cmd port 966 HG Port 6 Connection goes down RTS Oalways low always high Hg Port 7 DTR O always low 9 always high HH Ports Data Packing d Welcome Message Packet length 0 0 1024 H System Are Delimiter 1 00 Hex Cl Enable eros Delimiter 2 oo KH L Enabl i Hex nable J Save Configuration ima Restart Delimiter process BB A v Processed only when Packing length is 0 Force transmit 0 0 65535 ms i P1 P2 P3 P4 Ops OP6 Or OPs Apply the above settings to DJAll ports v gt hna lt TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to O the TCP connection will remain open even if there is no response to the keep alive packet
92. ecu dete ieaa tea Doce lace teas iene dete Bed Presb tu Diete Le Pret Deb ek Pee Ieee dean ida Velada 5 8 VES IRIE ote PN RM NR CN 5 8 elairreisigiareBEnr ur rel E uEsol aE 5 9 Configuring Routes to the Internet soie tot ta ut ada a t o iet eit dada dated do edet dada aat 5 10 Conhguring Routes to the Intranet a Oper epus pax ener Good Oper Eres aw NEE GE EE Gen 5 11 Configuring Multiple Point ROUteS ocooccccccccccccccnccnnnnnnncca senes enses snas 5 12 Configuring Serial Port Operation Modes coccion nn 6 1 POL E SetbIng Base S E necessitate le enc av me RM MEUM RN TRCN UE 6 2 DEVICE CONTO ADICIONA stb een lwan dude EEE OEE een EEE 6 3 Real COM Modena AE M MEE EM EM EM ME EET EAE E EU 6 3 a Av a OS Al A ete ene E b MM Md 6 5 SOCKEL 24 8 PICO A 6 6 PEP Server MOJE rio EA A A A A E Masala A A A Naame 6 6 TERCIO e tu ee 6 8 UDPRIM OO Ganea a a a a e ta a r a a a e a a do a a E eee 6 11 REGUNC O A O O O AA 6 12 A E ee ree 6 14 ORDA ARCA eO aras rana oa 6 14 DRDAS TCR A O 6 16 TerminalA ICA UON Saeimai ik sen i525 ers ita cdta acacia daa adiacdiddta capita ia adapta cdiaddta rere Pe ibid 6 18 Terminal ASCII TERM ASC rinane Iii 6 18 Terminal Bh TERN BEN ryote vals hate iota pele poete te voe pope Eo So oto poti obo a utate betebete efc ota Soo uoo to teeta res 6 19 REVESS EEA erosen cert mes exe ata ein arene ob cate nave cents OUO NICO NONOUI O OU OMNCO DIDI EN ME 6 21 Dial In QUEA DICO S iaaea a E 6 22 del 11 Lolo PA E A Ghar E E
93. ed the driver will not return any error even when a connection cannot be established to the CN2600 With this option enabled calling the Win32 Comm function will result in the error return code STATUS NETWORK UNREACHABLE when a connection cannot be established to the CN2600 This usually means that your host s network connection is down perhaps due to a cable being disconnected However if you can reach other network devices it may be that the CN2600 is not powered on or is disconnected Note that Auto Network Re Connection must be enabled in order to use this function Fast Flush only flushes the local buffer For some applications the user s program will use the Win32 PurgeComm function before it reads or writes data After a program uses this PurgeComm function the CN2600 driver will continue to query the CN2600 firmware several times to make sure no data is queued in the CN2600 firmware buffer rather than just flushing the local buffer This design is used to satisfy some special considerations However it may take more time on the order of several hundred milliseconds than a native COMI due to the additional time spent communicating across the Ethernet This is why PurgeComm works significantly faster with native COM ports on the PC than with mapped COM ports on the CN2600 In order to accommodate other applications that require a faster response time the new CN2600 driver implements a new Fast Flush option By default this
94. ed Parts COM Number COM3 current in use COM settin W Enable Redundant COM C Mapping P address 192 168 394 111 C Mapping IP address2 172180112 x Cancel 9 10 CN2600 Series Software I nstallation Configuration 7 On the Basic Settings page use the COM Number drop down list to select a COM number to be assigned to the CN2600 serial port that is being configured Select the Auto Enumerating COM Number for Selected Ports option to assign available COM numbers automatically in sequence to selected serial ports Note that ports that are in use will be labeled accordingly compone setng o Part Number 2 Fortis are Selected Basic Settings Advanced Settings Serial Parameters Security V Auto Enumerating COM Number for Selected Parts COM Number coma current in use COM gettin Enable Redundant COM C Mapping IP address 1921 68 324 111 Mapping lF sddress2 17216 0 11 2 E x Cancel 8 Enable Redundant COM which enables the 2 LANs automatically is the default If Disable Redundant COM is selected Real COM mode will be used and either LAN can be selected for mapping the IP address NOTE Before configuring the driver for Redundant COM mode you must first configure the corresponding port of the CN2600 s firmware for Redundant COM mode 9 Click the Advanced Settings tab to modify Tx Mode FIFO and Flash Flush ETZITTTOCENENNESSS o Part Number 1 Pa
95. equipment Temperature Caution Be careful when handling the CN2600 When plugged in the CN2600 s internal components generate heat and consequently the board may feel hot to the touch You should also observe the following common wiring rules e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point Do not run signal or communication wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately 2 2 CN2600 Series Hardware Installation e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separate e Where necessary it is strongly advised that you label wiring to all devices in the system Connecting the CN2600 8 16 s Power Connect the CN2600 s 100 240 VAC power line to its AC connector If the power is properly supplied the Ready LED will show a solid red color until the system is ready at which time the color changes to green WARNING CL 1 7 9 Isolation of multiple power sources amp CL 3 4 11 Multiple power sources Where there is more than one connection supplying HAZARDOUS VOLTAGES or HAZARDOUS ENERGY LEVELS to e
96. erial port settings on the CN2600 The same configuration options are also available through the telnet and serial console The following topics are covered in this chapter O Port Communication Parameters O Serial Parameters O Port Data Buffering Log O Port Modem Settings O Welcome Message CN2600 Series Additional Serial Port Settings Port Communication Parameters Main Menu Cd Overview 2 Basic Settings 0 Network Settings 243 Serial Port Settings EHE Porti 9 Operation Modes 9 Data Buffering Lo C3 Modem Settings CJ Port 2 CJ Port 3 CJ Port 4 CJ Ports CJ Port 6 CJ Port7 CJ Ports CJ welcome Message E E E E 2 System Management Es 3 System Monitoring Save Configuration Restart Communication Parameters Port 1 Port alias Serial Parameters Baud rate Hint Data bits Stop bits Parity Flow control FIFO Interface Apply the above settings to Total Solution for Industrial Device Networking 115200 tr a wj None k RTS CTS M Enable O Disable RS 232 v P1 P2 P3 P4 Ps L P6 P7 Ops CI All ports Port alias This optional field allows you to assign an alias to a port for easier identification Serial Parameters ATTENTION The serial parameters for the each serial port on the CN2600 should match the parameters used by the connected serial device
97. ers can issue commands across the network to set the line s configuration parameters such as baudrate data bits flow control condition etc Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link 6 16 CN2600 Series Configuring Serial Port Operation Modes status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both
98. ert RS 232 signals to RS 485 signals The connectors on the two CN2600 terminal servers will also need to use converters such as the Moxa TCC 100l In this way users can take advantage of RS 485 s multi drop feature to share data with the secondary CN2600 4 5 CN2600 Series Serial Port Operation Modes Terminal Applications Windows NT TCP IP CN2600 Telnet gt matt unu a5 Series e QD I RS 232 N Ze e MS Terminal Terminal Terminal Terminal applications involve connecting terminals to UNIX or Windows servers over a network A terminal connects to the appropriately configured serial port the CN2600 and the CN2600 transmits information to and from a UNIX or Windows server over the network through its Ethernet port You may need to check with your network administrator to determine the appropriate terminal mode All terminal modes support fast keys as used in many terminal applications Please refer to Chapter 4 Introducing Serial Port Operation Modes for detailed information and configuration instructions Terminal ASCII Mode Terminal ASCII mode can handle up to 8 sessions per port with the ability to switch between sessions on the same terminal This mode is used for text based terminals with no file transfer capability or encryption Terminal BIN Mode Terminal BIN mode allows one session per port and is used for terminal applications that include file transfer features 4 6 C
99. eway if applicable A gateway is a network computer that acts as an entrance to another network Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes The CN2600 needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the local network environment For correct gateway IP address information consult the network administrator ATTENTI ON In dynamic IP environments the firmware will try to get the network settings from the DHCP or BOOTP server 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server The first try times out after 1 second the second after 3 seconds and the third after 5 seconds If the DHCP BOOTP server is unavailable the firmware will use the default IP address 192 168 127 254 netmask and gateway settings DNS server 1 This is an optional field If your network has access to a DNS server you may enter the DNS server s IP address in this field This allows the CN2600 to use domain names instead of IP addresses to access hosts Domain Name System DNS is the way that Internet domain names are identified and translated into IP addresses A domain name is an alphanumeric name such as www moxa com that it is usually easier to remember than the numeric IP address A DNS server is a host that translates this kind of text based domain name into the actual I P address used
100. f a WINS Server is connected to the network enter the WINS Server s IP address in this field TCP IP uses IP addresses to identify hosts but users often use symbolic names such as computer names The WINS Server which uses NetBIOS over TCP IP contains a dynamic database to map computer names to IP addresses LAN speed default Auto You may configure the network speed for the built in Ethernet connection on the CN2600 I EEE802 3 Ethernet supports auto negotiation of transfer speed However some switches hubs require that the communication speed be fixed at 100Mbps or 10Mbps Advanced Network Settings You can access Advanced Network Settings by expanding the Network Settings item in the navigation panel Advanced Network Settings is where the routing protocol and gratuitous ARP are configured Total Solution for Industrial Device Networking 3 Main Menu CJ Overview 9 Basic Settings EMEN Network Settings 1 Basic Network Settings 2 Advanced Network Set EU Serial Port Settings HY System Management Network Settings Advanced Routing protocol None El Gratuitous ARP Denabled Send period soo 10 1000 sec HE System Monitoring CJ Save Configuration HY Restart What is RI P RIP Routing Information Protocol is a protocol used to manage routing information within a self contained network such as a corporate LAN Local Area Network or an interconnected group of such LANs By using RIP a gateway host wi
101. function is enabled If you have disabled Fast Flush and find that COM ports mapped to the CN2600 perform markedly slower than when using a native COM port try to verify if PurgeComm functions are used in your application If so try enabling the Fast Flush function and see if there is a significant improvement in performance 10 The Serial Parameters page shown in the following figure shows the default settings when the CN2600 is powered on However the program can redefine the serial parameters to different values after the program opens the port via Win 32 API AE Port Number 1 Fortis are Selected Basic Settings Advanced Settings Se al Parameters Security Sool All Selected Ports FT hese options will be saved on registry and used on few applications such as serial printer driver In general case you can ignore these settings Baud Fate sg y Parity Moe y Data Bits fa H Stop Bits h sz Flow Control None E x Cancel 9 12 CN2600 Series Software I nstallation Configuration 11 Click the Security tab to configure security settings Select the Enable Data Encryption option to enable data to be encrypted when transmitted over the COM ports After selecting the encryption option select the Keep connection option to start encrypting COM port communications immediately without restarting the COM ports If your application will open close a COM port frequently and the CN2600 is only used for one hos
102. gh so that the intended data transfer is completed ATTENTION Inactivity time is ONLY active when Connection Control see below is set to Any character lnactivity time Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Destination address 1 through 4 default None Specifying an IP address allows the CN2600 to connect actively to the remote host At least one destination must be provided TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 ATTENTION Up to 4 connections can be established between the CN2600 and hosts The connection speed or throughput may be low if any one of the four connections is slow since the one slow connection will slow down the other 3 connections ATTENTION The Destination IP address parameter can be the IP address domain name or the name defined
103. gs EHE Port 1 2 Operation Modes 3 Communication P Operation Modes Port 1 Application Mode TCP alive check time Inactivity time Total Solution for Industrial Device Networking Terminal v Terminal TERM ASC v 7 ko 99 min lo 0 99 min CJ Data Buffering Lo Auto link protocol None de 3 Modem Settings Primary host address TN bare Secondary host address OO HA Port 3 H Eere Telnet TCP port 23 EXA Ports Terminal HY Port 6 Terminal type lansi Ea Port 7 Max sessions 4v 1 4 Port g Change session AT LJ Welcome Message H System Management Vn E E System Monitoring Break 9 Save Configuration Interrupt HH Restart Authentication tyne None v Automatic Login Auto login prompt login Password prompt assword Login user name Login password P1 Or2 P3 L P4 Ops L P6 Or Lips Apply the above settings to Call ports TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check
104. gs G Porti Port 2 CJ Port 3 C Port 4 Ports CJ Port 6 3 Port7 Ports AU Welcome Message E REB vee EE EE amp System Management CJ System Monitoring CJ Save Configuration 1 Restart gt Network Settings Basic LAN1 IP configuration LAN1 IP address LAN1 Netmask LAN1 Gateway LAN1 speed LAN1 PPPoE user account LAN1 PPPoE password LAN2 IP configuration LAN2 IP address LAN2 Netmask LAN2 Gateway LAN2 speed LAN2 PPPoE user account LAN2 PPPoE password DNS server 1 DNS server 2 WINS function WINS server Total Solution for Industrial Device Networking DHCP v Auto v a Static v 192 168 126 254 299 299 999 _ 9Enable QO Disable v You can access Basic Network Settings by expanding the Network Settings item in the navigation panel Basic Network Settings is where you assign the CN2600 s IP address netmask Gateway and other IP parameters NOTE You must assign a valid IP address to your CN2600 before it will work in your network environment Your network system administrator should provide you with a unique IP address and related settings for your network First time users can refer to Chapter 3 Initial IP Address Configuration for more information 5 6 CN2600 Series Configuration with the Web Console
105. gs on the system RAM for all serial ports Note that this data is not saved when the CN2600 is powered off Each serial port is allotted 128 KB to store that port s log file Port Modem Settings Total Solution for Industrial Device Networking 3 Main Menu Modem Settings ran Overview 3 ram Basic Settings SE Network Settings ES Serial Port Settings BEI Port 1 FG Operation Modes Port 1 Enable modem O Enable Disable Initial string E Dial up ar A Communication P O Data Buffering Lo d Modem Settings Phone number P1 P2 P3 Or4 Ops OP6 P7 OPs Apply the above settings to E Eg Port 2 CI All ports EQ Port3 iu Submit ms Modem settings are used for the Dial In Out modes These settings will have no effect on ports configured for other modes Enable modem default Disable Initial string Use this field to configure the initial string that the modem will use to establish the connection For example AT amp SO 1 for auto answer Dial up Use this field to configure the modem s Dial up AT command string Phone number Use this field to configure the number that the user uses to dial out 7 3 CN2600 Series Additional Serial Port Settings Welcome Message Total Solution for Industrial Device Networking amp Main Menu m Overview ram Basic Settings Af Network Settings cre ganal Port SENGE Enable welcome message O Enable Disable
106. he CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off None 6 22 CN2600 Series PPPD Mode Configuring Serial Port Operation Modes Total Solution for Industrial Device Networking J Main Menu CJ Overview CJ Basic Settings 0 Network Settings 23 Serial Port Settings EMEN Port 1 3 Operation Modes 3 Communication P CJ Data Buffering Lo C3 Modem Settings Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Welcome Message eR m Bem gt Bm E iD ED m m p VOR 4 System Management H System Monitoring 2 Save Configuration AE Restart i gt Operation Modes Port 1 Application Mode Destination IP address Source IP address IP netmask TCP IP compression Inactivity time Link quality report Outgoing PAP ID PAP password Incoming PAP check Disconnect by Apply the above settings to Dial infout v PPPD O Enable Disable 0 0 65535 ms O Enable 9 Disable i None None v P1 P2 P3 CI All ports PPPD PPP on demand is used for dial in service
107. he factory defaults within the first 60 seconds that the CN2600 is powered on Remember to back up your configuration by exporting it to a file Your configuration can be easily restored by importing the file to the CN2600 This will save time if you have forgotten the password and need to reload the factory defaults 4 The CN2600 s web console will appear Total Solution for Industrial Device Networking 23 Main Menu ft welcome to Terminal Server CN2600 Series C Overview QU Basic Settings Model name CN2650 8 2AC S Network Settings Serial No 0 3 Serial Port Settings Firmware version 1 0 Build 07091017 HE Port 1 LAN1 IP address N A Ga Port 2 LAN1 MAC address 00 90 E8 12 69 87 LAN1 speed No link H Port 3 LAN2 IP address 192 168 126 254 23 Port 4 LAN2 MAC address 00 90 E8 12 69 88 H Ports LAN2 speed 100M Link 6 Porte Up time 0 days 00h 24m 08s Serial port 1 115200 None 8 1 Port 7 Serial port 2 115200 None 8 1 H Pots Serial port 3 115200 None 8 1 C3 Welcome Message Serial port 4 115200 None 8 1 S System Management Serial port 5 115200 None 8 1 H ME Serial port 6 115200 None 8 1 CJ System Monitoring Serial port 7 115200 None 8 1 Save Configuration Serial port 8 115200 None 8 1 9 Restart 5 4 CN2600 Series Configuration with the Web Console Web Console Navigation In the CN2600 web console the left panel is the navigat
108. he modes that are available Mode Once you have chosen an application select the mode The available configuration settings will vary depending on the mode that you have selected 6 2 CN2600 Series Configuring Serial Port Operation Modes Device Control Applications Real COM Mode MOXA Total Solution for Industrial Device Networking 3 Main Menu Operation Modes LJ Overview 2 Basic Settings Ee E Port 1 HI Network Settings i i i j Application Device Contro v EM Serial Port Settings PP S Port 1 Mode ESE M CJ Operation Modes TCP alive check time 7 0 99 min 3 Communication P Max connection 1 3 Data Buffering Lo Ignore jammed IP Enable Disable CJ Modem Settings Allow driver control Enable Disable i ut Port2 Connection goes down RTS O always low 9 always high Tum Port 3 DTR O always low always high E Port 4 Data Packing ee Packet length o m acket len DO 1024 HE Port 6 9 p K GJ Port 7 Delimiter 1 00 Hex L Enable E Porte Delimiter 2 00 Hex CI Enable CJ Welcome Message Delimiter process Do Nothing v Processed only when Packing length is 0 0 System Management Force transmit Oto 65535 ms rm nie ee aan P1 Dr Ops Om Oms Ore Orm Ops CJ Save Configuration Apply the above settings to 3 L AII ports BHL Restart v v a a a multiple hosts Real COM drivers open the port at the same time the COM
109. ill be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received 6 7 CN2600 Series Configuring Serial Port Operation Modes e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the
110. ill be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission 6 13 CN2600 Series DRDAS DRDAS Real COM Configuring Serial Port Operation Modes Total Solution for Industrial Device Networking YJ Main Menu CJ Overview 2 Basic Settings 0 Network Settings 243 Serial Port Settings 23 Porti 3 Operation Modes CJ Communication P Data Buffering Lo C3 Modem Settings Application Mode TCP alive check time Ignore jammed IP Primary IP address Backup 1 IP address Backup 2 IP address Backup 3 IP address Connection goes down DRDAS v DRDASRealCOM Y 7 K0 99 min O Enable Disable RTS Oalways law always high v Processed only when Packing length is Q zzii DTR Glways law O always high le al Data Packing HE Port 4 NEN Port5 Packet length Do 0 1024 HG Port6 Delimiter 1 00 Hex C Enable H Port 7 Delimiter 2 loo Hex C Enable j El Porte Delimiter process Do Nothing CJ welcome Message Force transmit i0 3 System Management 3 System Monitoring Apply the above settings to CJ
111. in the host table For some applications the user may need to send the data actively to the remote destination domain name Designated local port 1 through 4 default 5010 through 5013 Use these fields to specify the designated local ports Connection control default Startup None This setting determines the parameters under which a TCP connection is established or disconnected The different options are given in the following table In general both the Connect condition and Disconnect conditions are given Option Description Startup None default A TCP connection will be established on startup and will remain active indefinitely Any Character None A TCP connection will be established when any character is received from the serial interface and will remain active indefinitely 6 9 CN2600 Series Configuring Serial Port Operation Modes Option Description Any Character A TCP connection will be established when any character is received from the serial interface and will be disconnected when Inactivity time is reached DSR On DSR Off A TCP connection will be established when a DSR On signal is received and will be disconnected when a DSR Off signal is received DSR On None A TCP connection will be established when a DSR signal of NPort is On and will LN remain active indefinitely DCD On DCD Off A TCP connection will be established when a DCD On signal is received and will
112. ing HE Port 4 Packet length 0 1024 Hg Port5 HE Port 6 Delimiter 1 00 Hex C Enable HE Port 7 Delimiter 2 oo Hex CJ Enable 3 Ports Delimiter process Do Nothing Y Processed only when Packing length is 0 CJ Welcome Message Force transmit 0 0 65535 ms System Management n aud P1 P2 P3 P4 Opes OP6 P7 OPs H System Monitoring Apply the above settings to DAI port orts J Save Configuration P 0 Restart E v a i Destination address 1 through 4 default None In UDP mode you may specify up to 4 ranges of IP addresses for the serial port to connect to At least one destination range must be provided ATTENTI ON The maximum selectable IP address range is 64 addresses However when using multi unicast you may enter IP addresses of the form xxx xxx xxx 255 in the Begin field For example enter 192 127 168 255 to allow the CN2600 to broadcast UDP packets to all hosts with IP addresses between 192 127 168 1 and 192 127 168 254 Local listen port default 4001 This is the UDP port that the CN2600 listens to and that other devices must use to contact the CN2600 To avoid conflicts with well known UDP ports the default is set to 4001 Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sen
113. ing the connection If TCP alive check time is set to O the TCP connection will remain open even if there is no response to the keep alive packets TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its
114. ion panel and contains an expandable menu tree for navigating among the various settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the main window For example if you click on Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You must click on the Submit button to keep your configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your settings will not be retained Changes will not take effect until they are saved and the NPort is restarted You may complete this in one step by clicking on the Save Restart option after you submit a change If you need to make several changes before restarting you may save your changes without restarting by selecting Save Configuration in the navigation panel If you restart the CN2600 without saving your configuration the CN2600 will discard all submitted changes Basic Settings You may access Basic Settings in the navigation panel Server Settings Total Solution for Industrial Device Networking 2 Main Menu CJ Overview O Basic Settings Network Settings Basic Settings Server Settings
115. is installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP Installation 9 9 CN2600 Series Software I nstallation Configuration 6 Ports that have been activated will appear in black amp NPort Windows Driver Manager File COM Mapping View Help p u um o Rm E wit Add Remove c Inda Setting No COMP ES 2 COM4 192 168 354 111 351 357 Port os m 3 COMS 192 168 354 111 ghz 858 Port3 4 COM 22 132 158 34 111 953 969 Port4 5 COMe23 192 168 354 111 964 970 Pot5 b COMZA 132 158 34 111 955 971 Porth ni COM25 132 158 34 111 S56 972 Port B COM 26 192 168 354 111 957 973 Porte pl 3 COMe 192 168 354 111 958 974 Port3 10 COM 28 192 168 354 111 959 975 Port 0 d 11 COMe29 192 168 354 111 960 976 Port11 12 COM 30 192 168 354 111 961 977 Port 2 ES 13 COM31 132 158 34 111 962 978 Port 3 14 COM 32 132 158 34 111 963 979 Port 4 d 15 COM 33 132 158 34 111 964 980 Port 5 x 16 COM 34 192 168 354 111 965 981 Port 6 eux Total COM Part 16 E To re configure the settings for a particular serial port on the CN2600 select the row corresponding to the desired port and then click the Settings icon alo xj Port Number 2 Fortis are Selected Basic Settings Advanced Settings Serial Parameters Security V Auto Enumerating COM Humber for Select
116. ived Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specifie
117. l 5 8 CN2600 Series Configuration with the Web Console Configuring the Route Table You can access the Route Table by expanding System Management and then Misc Network Settings in the navigation panel The route table is where you configure how the CN2600 will connect to an outside network MOXA ee agile Route Table P J Overview C Basic Settings aC Network Settings CJ senal Port Satungs No Gateway Destination Netmask Metric Iface 1 lani j System Management Sy Misc Network Settings 3 CJ Accessible IP List 2 SNMP Agent 5 C DONS CJ Host Table Route Table CJ User Table 8 eJ Authenocguon Serv g J System Log Settings O Auto Warning Settings SC Maritenance Certificate lan lani lant lani lani lanl lant lani lani lant HC System Moritonng a Restart lant lani lant lanl 1 1 1 1 1 1 l 1 1 1 1 l 1 Save Configuration 14 1 lani 1 1 1 1 1 1 lani 1 lant 1 lant 1 lani 1 lant 1 lani 1 lani lanl lani lani AS uS D EU DSi ES SN IS 150 DA S5 250 NE 0 Iu EL eee EL 1 5 amp 1 2S AU 000 1 E S RA o 1 241 EL 56 1 1 1 lani 1 1 lant t gt Subm wa You are allowed up to 32 entries in the route table For each entry you must provide information on the gateway destination netmask metric hops and interface Gateway This is the IP address of the next hop router Destination This is the host s IP address or the network address of the route s
118. l be disconnected when the DSR signal is off 6 23 CN2600 Series Configuring Serial Port Operation Modes SLIP Mode Total Solution for Industrial Device Networking 3 Main Menu Q3 Overview jg Basic Settings Operation Modes HQ Network Settings Port 1 EI Serial Port Settings Application Dial infout v EMEN Port 1 Mode SLIP v 3 Operation Modes Cg Communication P CJ Data Buffering Lo 3 Modem Settings Destination IP address Source IP address IP netmask TCP IP compression O Enable Disable EX Port 2 HO Port 3 Inactivity time 0 0 65535 ms GS Port 4 Disconnect by None v Ports P1 Dra P3 D P4 Ops Ops Or7 Ops EG Port 6 Apply the above settings to Fall ports Eg Port 7 EC Porte d Welcome Message 3 System Management 9 System Monitoring Y Save Configuration E Restart ES lA lv SLIP provides standard SLIP service for both dial in and dial out Destination IP address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port I P netmask The IP netmask defines the netmask also known as the subnet mask for the SLIP connection TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for a
119. lect ESC previous menu 5 Use the arrow keys to move the cursor to IP address Use the DELETE BACKSPACE or SPACE keys to erase the current IP address and then type in the new IP address and press ENTER Note that if you are using a dynamic IP configuration BOOTP SHCP etc you will need to go to the IP configuration field and press ENTER to select the appropriate configuration 01 x CN2658 8 2AC_A 1 8 Basic 1 Advanced Quit Examine modify basic network settings ESC back to menu Enter select LANL IP configuration LANI IP address 192 168 060 102 LANI Netmask 255 255 255 0 LAHI Gateway L LAN1 speed Auto LANL PPPoE user account LANi PPPoE password LAN2 IP configuration Static LAN2 IP address C192 168 126 254 LAN2 Hetmask 255 255 255 0 J LANZ Gateway LANZ speed Auto LAN2 PPPoE user account LANZ PPPoE password DHS server 1 DNS server 2 WINS function Enable 1 WINS server 6 Press ESC twice to return to the previous page Press Y to confirm the modification ol x N2658 8 2AC CN2658 8 2AC_A 1 8 ETWORK MENU Basic 1 Advanced Quit Examine modify basic network settings Enter select ESC previous menu Warning ttt You have modified the configuration without saving Would you save it now 7 7 gt yes 7 Press ESC to return to the previous page 3 5 CN2600 Series Initial IP Address Configuration 8 Press A or use the arrow keys to select Save and
120. lesNPort Orv Manager Start Menu folder NPort Windows Driver Manager ris lt Back Cance 9 6 CN2600 Series Software I nstallation Configuration 6 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen In Windows XP a message will appear indicating that the software has not passed Windows Logo testing Click Continue Anyway to finish the installation ig Setup NPort Windows Driver Manager ioj xj A The software you are installing has not passed Windows Logo pd iS Tall me wh this testing is important E Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation 7 Click Finish to complete the installation of the CN2600 Windows Driver Manager Completing the NPort Windows Driver Manager Setup Wizard Setup has finished installing NPort Windows Driver Manager on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Launch NPort Windows Driver Manager Using NPort Windows Driver Manager After you install the NPort Windows Driver Manager
121. mation without your explicit consent i i Blocks first party cookies that use personally identifiable information without implicit consent Sites Import Advanced Default Pop up Blocker 9 Prevent most pop up windows from appearing v Block pop ups Settings ATTENTI ON If you are not using Internet Explorer cookies are usually enabled through a web browser setting such as allow cookies that are stored on your computer or allow per session cookies 5 2 CN2600 Series Configuration with the Web Console Trusted Site Settings For Windows 2003 users you may need to add the CN2600 s IP address to your browser s list of trusted sites 1 If you see the following window while attempting to view the web console click on Add to modify the list of trusted sites xi Content from the Web site listed below is being O blocked by the Internet Explorer Enhanced Security Configuration http 192 168 127 254 AAA AAA AAA Learn more about Internet Explorer s Enhanced Security Configuration IF you trust this Web site you can lower security settings for Add the site by adding it to the Trusted sites zone If you know this Web site is on your local intranet review help for instructions on adding the site to the local intranet zone instead Important adding this web site to the Trusted sites zone will lower the security settings for all content from
122. may need to refer to the server s documentation to 6 18 CN2600 Series Configuring Serial Port Operation Modes determine the appropriate terminal type For most applications this setting will be unnecessary and will have no effect Max Sessions default 4 This setting allows you to configure the maximum number of sessions allowed for the serial port Change Session default T 0x14 This field defines the quick key to change a session Quit defaultz E 0x05 This field defines the quick key to quit a session Break This field defines the quick key to send a break signal Interrupt This field defines the quick key for program termination Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description OO Local Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Auto login prompt default ogin Password prompt default assword Login user name Enter the terminal login ID here Login password Enter the password for the terminal login here Terminal BIN TERM_ BIN Total Solution for Industrial Device Networking 3 Main Menu Operation Modes QJ Overview CJ Basic Settings m Port 1 HL Network Settings 543 Serial Port Settings Appl PABon Meus uj _ EX Port 1 Mode Terminal TERM BIN v
123. minal Server CN2650 9 ZAC Console terminal type il ansi wrloo wtb5z 1 3 7 CN2600 Series Initial IP Address Configuration 7 The main menu should come up Once you are in the console you may configure the IP address through the Network menu item just as with the Telnet console Please refer to steps 4 to 11 in the Telnet Console section to complete the initial IP configuration E COM4 115200 Hone 8 1 A HSI CH2650 5 ZAC CN2650 3 ZA4C 0 1 0 d a DTR Overview Basic Mw Port System Monitor s ve Festart Exit RTS Examine modify the ethernet LAN port settings Enter select ESC previous menu State OPEN 1 m cT m Ready 3 8 4 Serial Port Operation Modes In this chapter we describe the various operation modes of the CN2600 CN2600 modes are grouped by type of application such as Device Control or Reverse Terminal The options include an operation mode that relies on a driver installed on the host computer and operation modes that rely on TCP IP socket programming concepts After selecting the proper operation mode please refer to Chapter 5 Configuration with the Web Console for detailed information on configuration parameters The following topics are covered in this chapter O Overview O Device Control Applications gt Real COM Mode gt RFC2217 Mode O Socket Applications gt TCP Server Mode gt TCP Client Mode gt UDP Mode O Redundant COM Dual host Redundant Data Acquisition System DRDAS
124. more information on passwords Finally you may also enable or disable the reset button 8 9 CN2600 Series System Management Settings Ping 2 NPort Web Console Microsoft Internet Explorer File Edit View Favorites Tools Help Q sxx X 7 ix a FN JO search 52 Favorites E L Lj 33 Address http 192 168 127 254 hd Go Total Solution for Industrial Device Networking Main Menu c Overview FIRE IE Gu Basic Settings HE Network Settings ae Serial Port Settings EESHIIESH Eo EE System Management Ae Misc Network Settings eg Auto Warning Settings ES Maintenance ra Console Settings La Ping ra Firmware Upgrade Ping Destination You can ping an IP address from the CN2600 web console in order to test the Ethernet connection Enter the IP address or domain name in the Destination field to make sure that the connection is OK Firmware Upgrade A NPort Web Console Microsoft Internet Explorer File Edit View Favorites Tools Help Q ese M M x B ON JO search 5 2 Favorites E L Lj 3 Address http 192 168 127 254 Go Total Solution for Industrial Device Networking 3 Main Menu Firmware Upgrade Q3 Overview p3 ram Basic Settings HE Network Settings i Note Upgrade firmware will discard your un saved configuration changes and restart e Serial Port Settings the system Select firmware file Browse 1 Warning ES System Management O Misc Netw
125. move mapped tty ports manually after entering the directory usr lib npreal2 driver you can modify npreal2d cf to delete servers and ports manually and then execute mxloadsvr to activate the modifications Removing Linux Driver Files A utility is included that will remove all driver files mapped tty ports and unload the driver To do this you only need to enter the directory usr lib npreal2 driver then execute mxuninst to uninstall the driver This program will perform the following actions Unload the driver Delete all files and directories in usr lib npreal2 Delete directory usr lib npreal2 e W N e Modify the system initializing script file The UNI X Fixed TTY Driver Installing the UNI X Driver 1 Log in to UNIX and create a directory for the MOXA TTY To create a directory named usr etc execute the command mkdir p usr etc 2 Copy moxattyd tar to the directory you created If you created the usr etc directory above then execute the following commands cp moxattyd tar usr etc cd usr etc 3 Extract the source files from the tar file by executing the command tar xvf moxattyd tar The following files will be extracted README TXT moxattyd c source code moxattyd cf an empty configuration file Makefile makefile VERSION TXT fixed tty driver version FAQ TXT 4 Compile and Link For SCO UNI X make sco For UnixWare 7 make svr5 For UnixWare
126. ngs l A icati DRDAS 23 Serial Port Settings Pp eann mnan E a3 Port 1 Mode _DRDAS TCP Server v CJ Operation Modes TCP alive check time 7 D 99 min Cd Communication P Inactivity time D ko 65535 ms A Data Buffering Lo Ignore jammed IP O Enable O Disable J Modem Settings Primary IP address HG Port 2 Backup 1 IP address Hm Port 3 G9 Port 4 Backup 2 IP address HG Ports Backup 3 IP address HE Port 6 TCP port 4001 E Port 7 Cmd port 966 oip caus Connection goes down RTS O always low 9 always high E LJ Welcome Message DTR O always low always high 3 System Management E T Data Packing H System Monitoring 9 Save Configuration Packet length 0 0 1024 H Restart Delimiter 1 00 Hex C Enable Delimiter 2 O0 Hex C Enable Delimiter process Do Nothing Y Processed only when Packing length is 0 Force transmit 0 0 65535 ms P1 Or2 P3 P4 Ops P6 Cp Ors Apply the above settings to DJAll ports v ES TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP co
127. nnection from another host after closing the connection If TCP alive check time is set to O the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified I nactivity time If this field is set to O the TCP connection is kept active until a connection close request is received Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Primary IP address The primary host s IP address If left blank then every host on the network cannot access the serial port Backup 1 IP address Backup host s IP address Backup 2 IP address Backup host s IP address Backup 3 IP address Backup host s IP address TCP Port TCP data port number Via the data port users can retrieve data through the async line TCP port command port number Via the command port us
128. nstallation The installer then displays a summary of the installation options B Setup NPort Search Utility Ready to Install Setup is now ready to begin installing MP or Search Ublity on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program FilessMNPartS earch Start Menu folder MPor Search Utility zu Cancel 6 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen CN2600 Series Software I nstallation Configuration 7 Click Finish to complete the installation of Terminal Server Search Utility a setup MPort Search Utility Completing the NPort Search Utility Setup Wizard Setup has finished installing MP art Search Utility on pour computer The application may be launched by selecting the Installed icons Click Finish to exit Setup Configuring NPort Search Utility The Broadcast Search function is used to locate all CN2600 servers that are connected to the same LAN as your computer After locating a CN2600 you will be able to change its IP address Since the Broadcast Search function searches by MAC address and not IP address all CN2600 servers connected to the LAN will be located regardless of whether or not they are part of the same subnet as the ho
129. nstructions Use a serial cable to connect the CN2600 s serial console port to your computer s male RS 232 serial port From the Windows desktop select Start gt All Programs gt PComm Lite gt Terminal Emulator The PComm Terminal Emulator window should appear From the Port Manager menu select Open or simply click the Open icon as shown below ES PComm Terminal Emulator Profile Port Manager Help ojal alejas sl 4 The Property window opens automatically Select the Communication Parameter tab and then select the appropriate COM port for the connection COMI in this example Configure the baudrate for either 460800 230400 115200 57600 38400 19200 or 9600 and then press OK x Communication Parameter Terminal File Transfer Capturing r COM Options Pat z Baud Rate 19200 y Data Bits a Parity None Stop Bits ji Flow Control Dutput State RTS CTS DTR ON C OFF XONAXOFF RTS ON C OFF 5 From the Property window s Terminal page select ANSI or VT100 for Terminal Type and click OK 6 Press lt Enter gt key to bring out the console screen If the CN2600 has been set up for password protection you will be prompted to enter the password After you enter the password or if password protection was not enabled you will be prompted to select the terminal mode Press 1 for ansi vt100 and then press ENTER E COM4 115200 None 8 1 Dumb Terminal Ter
130. nt 2 i lani v EXSY Misc Network Settings 3 1 lani C3 Accessible IP List 4 1 lani Wi E a SNMP Agent 5 1 lani Wi iie DDNS PO a 6 1 lanl r3 Host Table Route Table d lani m r User Table 8 1 lani v 3 l ra Authentication Serve 9 1 lani 7C System Log Settings 10 1 lani B j 2 Auto Warning Settings 11 1 lani mi EC Maintenance a a id in ani Y H Certificate HE System Monitoring 13 1 lani d Save Configuration 14 1 lanl HG Restart 15 1 lani 16 1 lani si 17 1 lani v Generally connections to the Internet are handled by assigning a gateway server in the network settings rather than through the route table 5 10 CN2600 Series Configuration with the Web Console Configuring Routes to the Intranet Ethernet TCP IP 203 67 6 252 ROUGE P Router 203 67 6 253 GRADON 203 67 6 254 202 65 66 2 P Router Ethernet T 202 65 66 Internet Modem Modem 202 65 66 4 202 65 66 5 PC Notebook In this example dial in users can make requests to Intranet hosts 202 65 66 4 or 202 65 66 5 which are on network 202 65 66 xxx located outside network 203 67 6 xxx You will need to add a route entry for the next hop router 203 67 6 252 that delivers requests to network 202 65 66 xxx The metric hop in this case is 2 route hops Total Solution for Industrial Device Networking Main Menu s Route Table C Overvie
131. nty Statement Rackmount Kit includes 2 brackets and 8 screws Desktop Kit includes 4 pads 1 2 CN2600 Series Front Panel CN2610 8 V4 CN2610 16 V4 CN2610 8 2AC CN2610 16 2AC CN2650 8 CN2650 16 CN2650 8 2AC CN2650 16 2AC CN26501 8 CN26501 16 CN26501 8 2AC CN26501 16 2AC Introduction LCM Display Panel Push Buttons LED Indicators LAN Indicators CM2650 8 2AC rerminar Res sar mer AA i OGITITTTT E coe 088 CHZ650 18 ZAC rarminal Ferrer a i i AEREA i FID M dence a ELA SN AAA CA2650 16 neminai Jerar 1 a p Fa m AAE IELEEISETEESE E zl ae thee CNZ610 8 2AC memas irra i i oy ar a e EEEE EES a AAA CNZE10 16 2AC terete Bene gt A UTTTTTT P AS Tesisi iare A SPECT CCFC S ff eee CNZ650I B 2 AC rece Serre 1 3 CN2600 Series Introduction Buttons and LEDs Description Reset Button Press the Reset button for 5 seconds to load factory defaults The CN2600 will beep twice when the configuration has been reset Push Buttons LEDs Ready Red Indicates that the CN2600 is receiving power Green Indicates that the CN2600 s OS is ready Green Indicates serial port transmission Used for configuring the IP address and other parameters Yellow Indicates serial port reception LAN 1 LAN 2 Green Ethernet link connection Off Ethernet cable is disconnected PWR 1 PWR 2 Red Power connection Off Power
132. nue or Cancel to exit Setup Les omes 9 5 CN2600 Series Software I nstallation Configuration 3 Click Next to install program files to the default directory or click Browse to select an alternate location a Setup NPort Windows Driver Manager Select Destination Location Where should NPort Windows Driver Manager be installed d Setup will install NPort Windows Driver Manager into the following folder To continue click Next If you would like to select a different folder click Browse C Program Files MPort Orv Manager Browse At least 1 4 MB of free disk space is required lt Back Sea 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder i Setup NPort Windows Driver Mat Where should Setup place the program s shortcuts E Setup will create the program s shortcuts in the following Start Menu folder To continue click Next F you would like to select a different folder click Browse NPort Windows Driver Manager Browse 5 Click Next to proceed with the installation The installer then displays a summary of the installation options a Setup NPort Windows Driver Manager Ready to Install Setup is now ready to begin installing NPort Windows Driver Manager on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Fi
133. ork Settings EJ Auto Warning Settings Es Submit EXSY Maintenance Submit r Console Settings Ping m Firmware Upgrade CJ Configuration Import A Confinuratinn Fennrt The CN2600 s firmware can be upgraded though the web console serial console or through NPort Search Utility If you have made any changes to your configuration remember to save the configuration first before upgrading the firmware Please refer to Save Configuration later in this chapter for more information Any unsaved changes will be discarded when the firmware is upgraded To upgrade the firmware simply enter the file name and click Submit The latest firmware can be downloaded at www moxa com 8 10 CN2600 Series System Management Settings Configurating I mport Export The CN2600 can share or back up its configuration by exporting all settings to a file which can then be imported into another CN2600 Total Solution for Industrial Device Networking J Main Menu i Overview f Basic Settings Ey Network Settings Configuration Import Configuration Import i i i Select configuration file Browse H Serial Port Settings g Browse Beg System Management IP configuration Import all configurations including IP configurations ie Misc Network Settings 83 Auto Warning Settings Submit EA Maintenance A Console Settings m Ping a Firmware Upgrade a Configuration Import a Configuration Export i Ma imm
134. ork transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits l stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If itis necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 4 CN2600 Series Configuring Serial Port Operation Modes
135. own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted 6 5 CN2600 Series Configuring Serial Port Operation Modes Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely
136. plications the CN2600 offers the following modes TCP Server TCP Client and UDP TCP Server Mode In TCP Server mode the serial port on the CN2600 is assigned a port number which must not conflict with any other serial 1 port on the CN2600 The host computer initiates contact with N TZ the CN2600 establishes the connection and receives data from the serial device This operation mode also supports up to 8 simultaneous connections enabling multiple hosts to collect data from the same serial device at the same time 2 As illustrated in the figure data transmission proceeds as follows med The host requests a connection from the CN2600 which is 1 Request a q connection RS 232 422 485 configured for TCP Server mode Proceed with Tne AM Device Once the connection is established data can be transmitted in data transmission M9 both directions between the host and the CN2600 TCP Client Mode In TCP Client mode the CN2600 can actively establish a TCP m connection to a pre defined host computer when serial data y arrives pra After the data has been transferred the CN2600 can automatically disconnect from the host computer by using the Inactivity time settings As illustrated in the figure data transmission proceeds as 2 follows The CN2600 configured for TCP Client mode requests a b oe connection from the host Qo Request a 2 l l connection RS 232 422 485 Once the connection is established d
137. port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Allow driver control default No This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control commands will be accepted with the most recent command received taking precedence Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data
138. quipment a prominent marking located close to the entry point provided for a SERVICE PERSON to gain access to the hazardous parts shall be provided to indicate which disconnect device or devices isolate the equipment completely and which disconnect devices can be used to isolate each section of the equipment At CAUTION This server may be shipped with multiple power supplies that require more than one connector to AC mains The AC power cords are considered to be the mains disconnect device for the server always disconnect power supply cords before opening up or servicing the server Connecting to the Network Connect one end of the Ethernet cable to the CN2600 s 10 100M Ethernet port and the other end of the cable to the Ethernet network There are 2 LED indicators located on the top left and right corners of the Ethernet connector If the cable is properly connected the CN2600 will indicate a valid connection to the Ethernet in the following ways Ma The top right corner LED indicator maintains a solid green color when the cable is properly connected to a 100 Mbps Ethernet network 1 8 The top left corner LED indicator maintains a solid orange color when the cable is properly xis connected to a 10 Mbps Ethernet network 1 8 Connecting to a Serial Device Use appropriately wired serial data cables to connect serial devices to the CN2600 s serial ports Connecting to the Console Port A console is a combination of key
139. r select RADIUS server IP 132 168 205 107 RADIUS key 1234 UDP port 1 1645 21812 1 Enable RADIUS accounting yes SHHP community name public SHHP trap server IP address Ethernet IP forwarding na Routing protocol None TEP retransmission timeout FIO data transfer tineaut 8 Click Apply 9 Right click RADIUS in the left information window and select Start You will now see that RADIUS is running Setting up Windows 2000 Hosts Open Start gt Programs gt Administrative Tools gt Routing and Remote Access Right click Server Local and select Configure and Enable Routing and Remote Access Click Next to continue 3 Select Remote access server and click Next to continue B Routing and Remote Access Me Xx i 5 s mE ae E s Routing and Remote Access Server Setup Wizard E Common Configurations fou can select from several common configurations Internet connection server Enable all of the computers on this network ta connect to the Internet Remote access server Enable remote computers to dial in to this network es Virtual private network VPH server Enable remote computers ta connect to this network through the Internet Network router Enable this network to communicate with other networks Manually configured server Start the server with default settings start e t Si Routing and Remote A fe 1ISPH E 5 CN2600 Series 4 Select Set up
140. rated into new editions of the publication Technical Support Contact I nformation Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 WWW moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents PREFOGUCUION PREMIT ooo ooo Ann 1 1 Product AA RO nn 1 2 an GLO O 1 2 AA PP eeaneie eee enien re reeiaen teenies ee reenter eee ree MTM CON UA OU NUM TROU NEU eee erate eer 1 2 Package Checklist E 1 2 Front Pane m IET 1 3 Rear PRONE ER een UU ee 1 4 Bottom RR tates 1 5 Hardware InstallaHo h incas aca cnica 2 1 DESC Daiichi iam ieee EE ere 2 2 ROCKO gj uc air as stent ECT TOt 2 2 WIN Re qUe ES id 2 2 Connecting the CN2600 8 160 S POWBF vacias 2 3 Connecting tothe NeW A UU M M PIN M MUNI dd 2 3 CONNECUNG toa Sera Di IC E sisena a 2 3 Connecting to the Console PU aa 2 3 Adjustable Pull High Low Resistors for the RS 485 Port ccccccceecceee ee ee cnn cnn cnn rn rr rr 2 4 Initial EP Address Configuration a 3 1 Static and Dynamic IP Addresses idad dada 3 2 Factory Default IP Add PES tt A A A ab 3 2 Contiguracion OPHION resas reiner 3 2 Terminal Server Search UNY lt a aia tau 3 2 al leg CONS M O OO E eer ne ree ere rrr rte 3 2 EG Consoler
141. rial Device Networking 3 Main Menu QJ Overview 3 Basic Settings Event Settings System Event i adu des Cold start O Mail Trap Serial Port Settings 2 Eysen Management Warm start O mail ClTrap HE Misc Network Settings Power 1 doen C mail EMEg Auto Warning Settings Power 2 down Mail C3 Event Settings Network Event Serial Event Setting Ethernet 1 link down O Mail DO Trap CJ E mail Alert Ethernet 2 link down DO mail Trap 1 SNMP Trap Config Event E Mainten i al A aS Console web text login auth fail O mail L Trap HL Certificate M ae IP changed O mail H System Monitoring m P m Password change i ll Save Configuration d O mail 3 Restart 8 6 CN2600 Series System Management Settings On the Event Settings page you may configure how administrators are notified of certain system network and configuration events Depending on the event different options for automatic notification are available as shown above Mail refers to sending an e mail to a specified address Trap refers to sending an SNMP Trap Cold start This refers to starting the system from a power off state or after upgrading your firmware Warm start This refers to restarting the CN2600 without turning the power off Power down Powerl and Power2 refer to the built in power jacks If either power fails the CN2600 will attempt to send an e
142. rosoft cam http msdn micresaft com hd Require server verification https For all sites in this zone Close 5 3 CN2600 Series Configuration with the Web Console After adding the CN2600 s IP address as a trusted site you should be able to view the web console by entering the CN2600 s IP address in your browser s address bar Opening the Web Console Open your web browser and enter 192 168 127 254 in the website address line This is the default IP address for the CN2600 if a new address has been assigned enter the new address instead Press ENTER to load the page ATTENTION The examples and figures in this chapter use the CN2600 factory default IP address of 192 168 127 254 If you have assigned a different IP address to your CN2600 be sure to adjust accordingly when following these directions Please refer to Chapter 3 Initial IP Address Configuration for details on how to configure the IP address 3 Enter the console password if prompted This will not apply if you did not enable password protection for your CN2600 The password will be transmitted with MD5 encryption over the Ethernet Web Console Login Username admir Password ATTENTION If you forget your password the ONLY way to configure the CN2600 is by using the reset button to reset all settings and load the factory defaults If you have disabled the reset button in your CN2600 configuration you may still use it to load t
143. rt s are Selected Basic Settings Advanced Settings Serial Parameters Security F ppp All Selected Ports The FIFO settings will overnite the firmware setting Tx Mode HiPertomance FIFO Ene Network Timeout 5000 ms 500 20000 M Auto Network Re Connection Return error if network is unavailable v Fast Flush Only flush local buffer Tx Mode Hi Performance is the default for Tx mode After the driver sends data to the CN2600 the driver immediately issues a Tx Empty response to the program Under Classical mode the driver will not send the Tx Empty response until after confirmation is received from the CN2600 s serial port This causes lower throughput Classical mode is recommended if you want to ensure that all data is sent out before further processing FIFO If FIFO is Disabled the CN2600 will transmit one byte each time the Tx FIFO becomes empty and an Rx interrupt will be generated for each incoming byte This will result in a faster response and lower throughput Network Timeout You can use this option to prevent blocking if the target CN2600 is unavailable 9 11 CN2600 Series Software I nstallation Configuration Auto Network Re Connection With this option enabled the driver will repeatedly attempt to re establish the TCP connection if the CN2600 does not respond to background check alive packets Return error if network is unavailable If this option is disabl
144. rward authentication requests to any access server that is compatible with Remote Authentication Dial In User Service RADIUS a Conr Refresh Help To configure 145 to read the remote access properties of user accounts in Active Directory on the Action menu click Register Server in Active Directory For more information about setting up 145 deployment scenarios and troubleshooting see Help New Client 5 Select New RADIUS Client to add a new RADIUS client You will then be able to begin using this function E 8 F CN 2600 Series Comparison Table meg PO AN iwer RAW RN y E Piwerip P y Wurpex Rr wer Wuipex TERw Bh WurmosTv Hxmy O NTRealcom aspp S we conse mepes ssHconsole 2 Ducreoore O SS ratos ARPA WINS Funeti n E SISIS X WINS Function DDNS iHe p Mime zone Setting A LocalTime Setting apos E S E dS X Mail Alert SIS
145. s 6 6 CN2600 Series Configuring Serial Port Operation Modes Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to O the TCP connection is kept active until a connection close request is received ATTENTION If used the Inactivity time setting should be greater than the Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Max connection default 1 This field is used if you need to receive data from different hosts simultaneously When set to 1 only a single host may open the TCP connection to the serial port When set to 2 or greater up to the specified number of hosts may open this port at the same time When multiple hosts establish a TCP connection to the serial port at the same time the CN2600 will duplicate the serial data and transmit it to all the hosts Ethernet data is sent on a first in first out basis to the serial port when data comes into the CN2600 from the Ethernet interface Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more
146. s since it provides PPP services only when receiving a request from a remote PC Destination I P address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port I P netmask The IP netmask defines the netmask also known as the subnet mask for the PPP connection TCP I P compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Link quality report default No Setting this field to Yes allows the CN2600 to disconnect a connection if the link noise exceeds a certain threshold Outgoing PAP ID This is the dial out user ID account PAP password This is the dial out user password Incoming PAP check default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description Local None RADIUS Verify the ID against the CN2600 User Table Verify the ID against the external RADIUS server Authentication is not required Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection wil
147. s snmpOutGetNexts SCs utsetRequests CS smmutGetespomses a swmwowfras Coo swmnableAuthenraps O B 2 C Dynamic Domain Name Server This appendix explains how to use the CN2600 with DDNS When the CN2600 receive its IP address from a DHCP Dynamic Host Configuration Protocol server remote servers will be unable to access it using a fixed IP address With DDNS Dynamic Domain Name Server a remote server can access the CN2600 using its domain name instead of its IP address Overview The following is a summary of the process 1 The CN2600 sends a request for an IP address to the DHCP server At the same time it notifies the DHCP server of its desired server name CN2600 in the illustration according to the option 12 standard The DHCP server replies with the IP address that is assigned to the CN2600 along with the domain name moxa com in the illustration and the IP addresses for the DNS server and gateway If the CN2600 has authorization to update the DNS server it will register its FQDN Fully Qualified Domain Name with the DNS server The CN2600 s FODN will be in the format server name domain name CN2600 moxa com in the illustration If the CN2600 is not authorized to update the DNS server the DHCP server can be used to update the DNS server The DHCP server will register the DNS server with the PTR RR the record of request for a domain name with IP address DHCP Server DHCP Request CN2600 Series Host
148. s so in this case it must be greater than or equal to 10 ms If itis necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port TCP Client Mode MOXA Total Solution for Industrial Device Networking C Main Menu p F Operation Modes LJ Overview 2 Basic Settings z i Port 1 H Network Settings EMS Serial Port Settings id Ei X 52 Port 1 Mode TCP Client Y Operation Modes TCP alive check time 0 99 min 3 Communication P Inactivity time 0 0 65535 ms UC Data Buffering Lo Ignore jammed IP O Enable 9 Disable d A CQ Modem Settings Destination address 1 Port 4001 i ids Destination address 2 Port 4001 ini Destination address 3 Port 4001 Bg Ports Destination address 4 Lo Port 4001 3 Port 6 Designated local port 1 5010 B Port7 Designated local port 2 5011 T m Port B Designated local port 3 5012 EU emeret Bern aq System Monitoring Connection control Startup None Mj 1 Save Configuration Data Packing AA Restart Packet length 0 0 1024 Delimiter 1 00 Hex C Enable Delimiter 2 00 Hex O Enable Delimiter process Do Nothing vj Processed only when Packing length is 0 Force
149. s the default is set to 4001 Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Map keys lt CR LF gt default CR LF This specifies how the ENTER key is mapped from the Ethernet port through the serial port lt CR LF gt carriage return line feed i e the cursor will jump to the next line and return to the first character of the line carriage return i e the cursor will return to the first character of the line line feed i e the cursor will jump to the next line but not move horizontally 6 21 CN2600 Series Configuring Serial Port Operation Modes Dial I n Out Applications PPP Mode Total Solution for Industrial Device Networking 3 Main Menu 9 Overview 2 Basic Settings 2 Operation Modes 2 Communication P CJ Data Buffering Lo C3 Modem Settings Operation Modes Destination IP address Source IP address IP netmask TCP IP compression 4 Network Settings Port 1 9 Serial Port Settings Application Dial in out Mj EMEN Porti Mode PPP v O Enable 9 Disable Bg Port 2 4 Port 3 Inactivity time 0 O 65535 ms 23 Port 4 Link quality report O Enable 9 Disable
150. s IP address assigned to this serial port I P netmask The IP netmask defines the netmask also known as the subnet mask for the SLIP connection TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off 6 25 CN2600 Series Configuring Serial Port Operation Modes Dynamic Mode Total Solution for Industrial Device Networking icy Main Menu A E Overview Operation Modes Cu Basic Settings Cr Network Settings Port 1 E Serial Port Settings Application Dial in out vj E Port 1 Mode Dynamic CM Operation Modes TERM BIN mode Enable O Disable a cammunicanon P PPPD mode Enable O Disable 1 E a pata BH ED SLIPD mode O Enable Disable rad peus Authentication type None e cia Port 3 Pi P2 P3 P4 Ops OP6 P7 Lips Hg Port 4 CJ all ports 8C3 Ports 3 Port 6 Bg Port 7 8C3 Porte g Welcome Message ae System Management Eg System Monitoring A Save Configuration HA Restart ES
151. s JON X a Ir lA o ss lo Routing and Remote Access Server Setup Wizard IP Address Assignment a You can select the method for assigning IP addresses to remote clients y How do vou want IP addresses to be assigned to remote clients C Automatically IF you use a DHCP server to assign addresses confirm that it i configured properly IF veu do not use a DHCP server this server will generate the addresses start ar Si Routing and Remote A fe 2 03 PM E 6 RADI US Server CN2600 Series RADIUS Server B Routing and Remote Access 15 4 MEE a CAJA Action Routing and Remote Access Server Setup Wizard Address Range Assignment ou can specify the address ranges that this server will use to assign addresses to remote clients the Type a starting IP address and either an ending IP address or the number of Ad addresses in the range F Start IP address End IP address Number of addresses Cancel Back Hents Cancel Astart e t S Routing and Remote A qE 2 05 PM 7 Select Yes want to use a RADIUS server and click Next B Routing and Remote Access lel Ei Zz A ZEN a Fh A Action Routing and Remote Access Server Setup Wizard Managing Multiple Remote Access Servers You can manage all of your remote access servers centrally A Remote Authentication Dial In User Service RADIUS server provides a central authentication database for multiple remote access ser
152. s Read write authentication mode allows you to configure the authentication mode for read write access For each level of access you may configure the following User name Use this optional field to identify the user name for the specified level of access 8 3 CN2600 Series System Management Settings Authentication mode default Disable Use this field to select MD5 or SHA as the method of password encryption for the specified level of access or to disable authentication Privacy mode default Disable Use this field to enable to disable DES CBC data encryption for the specified level of access Password Use this field to set the password for the specified level of access Privacy Use this field to define the encryption key for the specified level of access DDNS Please refer t to Appendix C Dynamic Domain Name Server for information on setting up DDNS on your CN2600 Host Table Total Solution for Industrial Device Networking amp J Porto BJ Port 10 BA Port 11 GQ Port 12 B3 Port 13 BA Port 14 BHEJ Port 15 EA Port 16 gp welcome Message Host Table Zz o Host Name Host IP Address EHES System Management EXSY Misc Network Settings i ra Accessible IP List SNMP Agent DDNS Host Table Route Table P User Table rm Authentication Server E System Log Settings E Auto Warning Settings 2 Eg Maintenance E Certificate Bg System Monitoring Gu Save Configuration EJ Restart 0
153. se The host computer will not be able to use the COM ports until the COM ports are activated Click Yes to activate the COM ports at this time or click No to activate the COM ports later Ki Exil is Add Remove El Ez Unda Setting m LUMTS 168 34 219 950 966 Pont fa 2 COM19 192 166 34 219 951 96 Port 2 i 3 COM O 192168 34219 952 968 Port3 E 4 COM 1 192 168 34219 853 383 Port 4 5 COM22 192 168 34219 954 970 Parth Ed 5 COM 23 132 158 34 218 855371 Port L1 T COM24 192 166 34 219 956 972 Port Ed B8 CUM 25 132 158 34 218 857373 Fort 4 g COM E 132 158 34 218 958 974 Port3 Lcd 1 COM 192 166 34 219 959 975 Port 0 11 COM 28 132 158 34 213 960 976 Partl 1 E sd 12 COM 8 132 158 34 213 S8B1 37 Part1 2 4 13 COM30 132 158 34 213 9623978 Port 3 IM 14 Ch a 1021En 324 10 002 070 Do fn m 15 Information X L T 16 4 Total COM Port 5 n Windows XP a message is displayed during activation of each port indicating that the software has not passed Windows Logo certification Click Continue Anyway to proceed Hardware Installation B NPort Communication Port 1 has not passed Windows Logo testing to verify its compatibility ell me why this testin with Windows XP is impor Continuing your installation of this software may impair either immediately or in the future Micros oft strongly recommends that you stop th
154. solation models Software ASCII Binary terminal modes with up to 8 Telnet and Rlogin sessions Point to Point Protocol PPP and PPPD Serial Line Internet Protocols SLIP and SLIPD Dynamic auto recognition of Terminal SLIP or PPP Dial on demand Dial out CN2600 series Terminal Server Proprietary Protocol ASPP for TCP IP socket programming RAW mode for transparent data transmission Reverse Telnet SNMP Agent for network management Network protocols TCP IP UDP ICMP NetBEUI DHCP Application protocols Telnet Rlogin Rtelnet RAW TCP RAW UDP WINS DRDAS DNS Multi Host Security protocols RADIUS Dial back PAP CHAP Local user password Real COM port drivers Windows 95 98 ME NT 2000 Windows XP 2003 Vista 2008 7 8 x86 x64 2012 x64 Real TTY drivers Linux kernel 2 4 x 2 6 x 3 x Fixed TTY Drivers SCO Unix SCO OpenServer UnixWare 7 UnixWare 2 1 SVR 4 2 QNX 4 25 QNX 6 Solaris 10 FreeBSD AIX 5 x Static Routing RIP I II protocols Windows like administrative CONSOLE utility from a fixed console port or by Telnet from a networked host Password protection and extensive user verification functions Easy firmware upgrade via Flash ROM Package Checklist All CN2600 dual LAN terminal servers are shipped with the following items CN2600 dual LAN terminal server ac power cord Document and Software CD ROM Quick Installation Guide English and Simplified Chinese versions RJ45 Loopback Tester Product Warra
155. st 1 Open NPort Search Utility and then click the Search icon I NPort Search Utility Seles Elle Function View Help 2 a x B Lo Exit Search Search IP Locate Console issia F parade No 2 Mode MAC Address IP Address MAC Address2 IP Address2 The Searching window indicates the progress of the search Searching for NPort Found 1 NPort s 5 second s left MAC Address IP Address MAC Address2 IP Address2 CN2610 16 00 90 E8 0E F 4 0 192 168 32 65 00 90 E8 0E F4 0F 192 168 34 65 9 4 CN2600 Series Software I nstallation Configuration 2 When the search is complete all CN2600 servers that were located will be displayed in the NPort Search Utility window lS NPort Search Utility File Function View Help F 2 a ai EB an a Exit Search Search IP No Model MACAddress IP Address1 MAC Address2 IP Address2 Status 1 CN2610 16 00 90 E8 0E F4 0E 192 168 32 65 00 90 E8 0E F4 0F 192 168 34 65 To modify the configuration of the highlighted CN2600 click on the Console icon to open the web console This will take you to the web console where you can make all configuration changes Please refer to Chapter 5 Configuration with the Web Console for information on how to use the web console 8 NPort Search Utility File Function View Help ri a Zi l n Exit Search Search IP Console Assign IP Uparade o Model MAC Address1 IP Address MAC Address
156. st need to enter the old password Leave this blank if you are setting up password protection for the first time To set up a new password or change the existing password enter your desired password under both New password and Confirm password To remove password protection leave the New password and Confirm password boxes blank ATTENTI ON If you forget the password the ONLY way to configure the CN2600 is by using the reset button on the CN2600 s casing to load the factory defaults Before you set a password for the first time it is a good idea to export the configuration to a file when you have finished setting up your CN2600 Your configuration can then be easily imported back into the CN2600 if you need to reset the CN2600 due to a forgotten password or for other reasons Please refer to the section on Configuration Import Export earlier in this chapter for more details 8 12 CN2600 Series System Management Settings Certificate Ethernet SSL Certificate I mport 3 Total Solution for Industrial Device Networkin CX Main Menu E Overview i Basic Settings Eg Network Settings Ethernet SSL Certificate Import Installed Certificate Issued to 192 168 127 254 HI Serial Port Settings Issued by 192 168 127 254 A System Management Valid from 2027 4 3 to 2037 4 2 YO Misc Network Settings B0 Auto Warning Settings ae Select SSL OWT Toa HH Maintenance certificate key file Browse EMEg Certificate Gl
157. st s IP address Backup 3 IP address Backup host s IP address Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second 6 14 CN2600 Series Configuring Serial Port Operation Modes delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should b
158. t you can enable this option to speed up the opening closing time However this will result in your host tying up the COM port so that other hosts cannot use it Select the Apply All Selected Ports option to enable the security settings to be applied to all COM ports AE Port Number 1 Ports are Selected Basic Settings Advanced Settings Serial Parameters Security F Sool All Selected Ports Enable Data Encryption Keep connection Redundant COM does not support security function x Cancel 12 To save the configuration to a text file select Export from the COM Mapping menu You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host amp NPort Windows Driver Manager B nml x File CM Mapping view Help Ft add Ctrl a m E Ex fie Remove Ctrl O App Undo Setting a YP Address 1 IP Address 2 tpm Ef Setting Ctrl C 192 169 127 254 950 966 Porti 192 168 126 254 950 966 2 E ams 192168127254 951 967 Porte 192 168 126 254 951 967 3 PA z 192 766 127 254 982 968 Ports 192 168 126 254 95 958 4 Undo rte 192158127254 S5x969 Pot4 192 168 126 254 953 969 F HE Export 132158127254 354370 Parth 132 158 125 254 954 970 b x SEDI 192 168 127 254 855971 Porth 192 168 126 254 355 371 T am Import 192 168 127 254 956 972 Port 192 168 126 254 855 877 B TIT 132158127 254 3857373 Porte 132 158 125 254 957973
159. t 3 TCP port 4001 ame panas Terminal m Ports IE port 6 Authentication type None y A Port 7 Map keys lt CR LF gt CRLF y 3 Port 8 MpriMDr Fra Drs Pers Dro Cer Mrs p Apply the above a Port 9 settings to po fF pio pii p12 pi3 pi4 pis P16 m Port 10 FT All ports HE Port 11 HE Port 12 Bg Port 13 Submit Aaa Meek 1A TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to O the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 min This field specifies the idle time setting for auto disconnection A setting of O min will cause the port to remain connected even if idle TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP port
160. t Explorer OS NPort Web Console Microsoft Internet A NPort Web Console Microsoft Internet Explorer OS File Edit View Favorites Tools Help Q ak X x B OD J Search 52 Favorites al SE ca A EZ Ly i Address http 192 168 127 254 Go Total Solution for Industrial Device Networking E Main Menu NA onsole settings QJ Overview g uu Basic Settings HTTP console Enable Disable RH Network Settings l i 4 HTTPS console Enable C Disable BC Serial Port Settings Telnet console Enable C Disable HS System Management r SSH console i e Misc Network Settings En DA e Auto Warning Settings Reset button Always Enable C Disable after 60 sec 0 EG Mintsn3nES LCM read only protection writable C Read only Console Settings eee _ Submit QJ Firmware Upgrade ran Configuration Import On this screen access to different CN2600 configuration console options HTTP HTTPS Telnet SSH can be enabled or disabled The CN2600 front panel known as the LCM Liquid Crystal Module may be configured for read only or writeable access In other words you can use the front panel to check console settings only read only access or to actually make changes to the settings writeable access Note that if the console is password protected and LCM is configured for writeable access you will need to enter the password to submit any console setting changes Please refer to Change Password later in this chapter for
161. t No This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control commands will be accepted with the most recent command received taking precedence Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals 6 3 CN2600 Series Configuring Serial Port Operation Modes Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to th
162. t as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTI ON In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received 6 11 CN2600 Series Configuring Serial Port Operation Modes e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimi
163. t forget to press SEL to confirm your selection In the IP config menu use the UP and DOWN buttons to select the option that matches your IP environment static DHCP etc Press SEL to confirm your choice You may also press MENU to cancel your selection and return to the previous submenu 5 You should be back in the Network setting menu From the Network setting menu select I P address 6 Use the UP and DOWN buttons to modify the digit currently selected by the blinking cursor Press SEL to move to the next digit Continue modifying the IP address until all digits have been entered If you make a mistake press MENU to cancel all changes and return to the Network setting menu You cannot go back one digit 7 Once you have finished modifying the I P address your changes are saved but not in effect In order for your changes to take effect you will need to restart the CN2600 You may view and modify your changes by selecting IP address at the Network setting menu again 8 Press the menu button to exit out of the Network setting menu and return to the Main Menu Use the UP and DOWN buttons to select Save Restart and press SEL Use the UP and DOWN buttons to select Yes and press SEL to restart ARP You may use the ARP Address Resolution Protocol command to set up an IP address for your CN2600 The ARP command tells your computer to associate the CN2600 s MAC address with an IP address Afterwards use Telnet to access the CN2600 and its I
164. taneously When set to 1 only one specific host can access this port of the CN2600 and the Redundant COM driver on that host will have full control over the port When set to 2 or greater up to the specified number of hosts Redundant COM drivers may open this port at the same time When multiple hosts Redundant COM drivers open the port at the same time the COM driver only provides a pure data tunnel no control ability The serial port parameters will use firmware settings instead of depending on your application program AP Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send data back to the driver on the host Data will be sent first in first out when data comes into the CN2600 from the Ethernet interface 6 12 CN2600 Series Configuring Serial Port Operation Modes ATTENTION When Max connection is greater than 1 the CN2600 will use a multi connection application i e 2 to 4 hosts are allowed access to the port at the same time When using a multi connection application the CN2600 will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted properly Ignore jammed IP default No This option determines how the
165. te was successful Telnet Console Depending on how your computer and network are configured you may find it convenient to use network access to set up your CN2600 s IP address This can be done using Telnet ATTENTI ON Figures in this section were taken from the CN2600 s Telnet console l From the Windows desktop select Start Run and then type telnet 192 168 127 254 in the Run window for LAN 1 or telnet 192 168 126 254 for LAN 2 If your IP address is different from the default setting use your IP address instead Click OK Hun EA Ei Type the name of a program folder document ar Internet 3 resource and Windows will open it For you Oper telnet 192 168 127 254 Cancel Browse 2 The console terminal type selection is displayed as shown Enter 1 for ansi vt100 and press ENTER to continue 5 Telnet 192 168 0 102 Terminal Server CH265B 8 2RhC Console terminal type 1 ansirutiBB 2 ut5z2 gt 1 3 Press N or use the arrow keys to select Network and then press ENTER H265H 8 2nC GHz658 8 2n6c B 1 8 Overview Basic Dieta e Port System Monitor save Kestart Exit Examine modify the ethernet LAN port settings Enter select ESC previous menu 3 4 CN2600 Series Initial IP Address Configuration 4 Press B or use the arrow keys to select Basic and then press ENTER Es E CN265 8 2AC_ 1 8 a Basic 1 fiduanced Quit p Examiners modify basic network settings Enter se
166. tenance A Console Settings m Ping CJ Firmware Upgrade Configuration Import m Configuration Export i Load Factory Default y 3 Change Password E Certificate a TN A AN Y A Total Solution for Industrial Device Networking Load Factory Default Click on Submit to reset all settings including the console password to the factory default values To leave the IP address netmask gateway and WLAN profile settings unchanged make sure that Keep IP Settings is enabled Reset to Factory Default Iv Keep IP settings Submit This function will reset all of CN2600 s settings to the factory default values All previous settings including the console password will be lost If you wish to keep the CN2600 IP address netmask and other IP settings make sure Keep IP settings is checked off before loading the factory defaults Change Password Total Solution for Industrial Device Networking E Main Menu a Overview 2 Basic Settings E ag Network Settings Change Password Password ils i Old password Po H Serial Port Settings P cim System Management dc dl JE BJ Misc Network Settings Confirm password EC Auto Warning Settings H Maintenance Console Settings Submit Ping Firmware Upgrade Configuration Import Configuration Export Load Factory Default Change Password EC Certificate E Swetem Mnnitnrina For all changes to the CN2600 s password protection settings you will fir
167. ter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to 0 the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in
168. teu NN duobus e I icd I Mrd C DENAN E 5 SEL NO UNICOS 2003 Ss m E 7 F CN 2600 Series Comparison Table cooonccccccccnnnnccononnnnnconnnnnnn cnn F 1 1 Introduction NOTE NOTE Moxa s CN2600 series of dual LAN terminal servers is available in models with 8 or 16 RS 232 or RS 232 422 485 ports and all models come with two 10 100 Mbps Ethernet LAN ports The CN2600 dual LAN terminal servers are used to connect terminals modems printers and other asynchronous serial devices to LAN hosts The CN2600 dual LAN terminal servers comply with TCP IP and IEEE 802 3 specifications using standard Ethernet 10 100BaseT and twisted pair 10 100BaseTX cable as the data transmission medium In this manual we often refer to all terminal servers in the CN2600 series collectively as the CN2600 The wide temperature model does not have an LCM Display panel and push buttons The LCM description in this manual applies only to standard temperature models The following topics are covered in this chapter O Product Features gt Hardware gt Software Package Checklist Front Panel Rear Panel Bottom Label 000 0 CN2600 Series Introduction Product Features Hardware Dual LAN ports auto detecting 10 100 Mbps Ethernet 8 MB RAM 16 MB Flash ROM Tx Rx LEDs for each serial port System Status LEDs Ethernet Status LEDs 8 or 16 RJ 45 RS 232 serial ports with up to 921 6 Kbps transmission speed 2 kV Serial Line Protection for i
169. th a router can send its entire routing table which lists all the other hosts it knows about to its closest neighbor host every 30 seconds The neighbor host in turn will pass this information on to its closest neighbor and so on until all hosts within the network have the same routing path information This state is known as network convergence RIP uses a hop count as a way of determining network distance Other protocols use more sophisticated algorithms that also include timing After receiving a packet headed for a specific destination a network host with a router uses the routing table information to determine the next host to route the packet to RIP is considered an effective solution for small homogeneous networks For larger more complicated networks transmitting the entire routing table every 30 seconds can bog down the network with a lot of extra traffic RIP 2 is an extension of RIP Its purpose is to expand the amount of useful information contained in RIP packets and to add security elements RIP 2 has become the standard version of RIP and the original RIP is no longer used Routing Protocol You may select which routing protocol if any your network will employ Gratuitous ARP n some applications you may need the CN2600 to send broadcast packets to update the ARP table on the server If you enable this function and set the send period the CN2600 will send periodically send broadcast packets at the specified time interva
170. the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits l stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If itis necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 15 CN2600 Series Configuring Serial Port Operation Modes DRDAS TCP Server Total Solution for Industrial Device Networking E Main Menu 4 Operation Modes LJ Overview 9 Basic Settings e Port 1 H Network Setti
171. then press ENTER Press ENTER again to confirm the Save command x CN2658 8 2AC_ 1 8 ueruiew Basic Metwork Port System Monitor Esfwe 1 Restart Exit Save current configuration to flash ROM ESC back to menu Enter select 9 Press R or use the arrow keys to select Restart and then press ENTER oj x CN2658 8 2AC_ 1 0 ASI EE AO SA A A Restart MR Restart the vhole system or selected serial ports Enter select ESC previous menu 10 Press S or use the arrow keys to select System and then press ENTER to restart the CN2600 CH265H 8 2nC B 1 8 Sustem IB PO NE iba Restart the server ESC back to menu Enter select Warning ttt Restart system will disconnect all ports and clear all status value Enter continue ESC cancel 3 6 CN2600 Series Initial IP Address Configuration Serial Console The CN2600 supports configuration through the serial console which is the same as the Telnet console but accessed through the RS 232 console port rather than through the network Once you have entered the serial console the configuration options and instructions are the same as if you were using the Telnet console The following instructions and screenshots show how to enter the serial console using PComm Terminal Emulator which is available free of charge as part of the PComm Lite suite You may use a different terminal emulator utility although your actual screens and procedures may vary slightly from the following i
172. then select Properties m Microsoft Management Console iis Console Rootynternet Information Server rats Al ES f Console Window Help amp x ae gt Action View xean 2 panse E Console Root Nam J Pah zi e Internet Information Server ratsnt4 E SD enun als Site 3 Default Web Site Start sS Administration W Gr i Default SMTP Sit Pause 263 Default NNTP Sit 4 9 Microsoft Transaction S E Task y New window from here Refresh v Scope Pane Description Bar Properties for the selected ite SS E 4 CN2600 Series RADIUS Server 6 Select Service Verify that the RADIUS ports assignments match your configuration Authentication 1645 or 1812 Accounting 1646 or 1813 7 Select Client and then click Add Enter the CN2600 s IP address in the IP address field Enter the CN2600 s RADIUS key in the password field This must match the RADIUS key that you set in the CN2600 console GO Internet Authentication Service Properties ratsnt4 Serice Lagging Clients Froliles Chents are network access devi Gece iN password shared secret wit e d aeaa US Authentication requests can be ri Client Location Donne El Y B Tpiact it a nid Haxaseruer Ue Info ETE Host table Route table User table Quit Exanine mnadif asyhe eeruer advance configuration EXSL D ck to menu Ente
173. this web site for all applications including Internet Explorer You may also directly access the list of trusted sites through Internet Options in the Tools menu of Internet Explorer Select the Security tab then click on the Trusted Sites icon and on the Sites button General Security Privacy Content Connections Programs Advanced Select a Web content zone to specify its security settings e amp Oo o Internet Local intranet 3E CRESCE Restricted sites Trusted sites This zone contains Web sites that you Gites trust not to damage your computer or data Security level for this zone Custom Custom settings To change the settings click Custom Level To use the recommended settings click Default Level Custom Level Default Level Cancel Apply 2 In either case the window below should appear showing the list of sites that you have configured Internet Explorer to trust Add the IP address of your CN2600 here the factory default LAN1 IP address is 192 168 127 254 and default LAN2 IP address is 192 168 126 254 You can add and remove web sites From this zone All web sites in this zone will use Ehe zone s security settings Add this Web site to the zone http 1192 168 127 254 Web sites http 10 update microsoft corm https i update microsoft com http windowsupdate microsoft com https windowsupdate microsoft com http jigo mic
174. time is set to O the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 min This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to O the TCP connection is kept active until a connection close request is received ATTENTI ON Inactivity time should at least be set larger than that of Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough such that the intended data transfer is completed Auto Link Protocol If this field is set to None the CN2600 will not connect to the host automatically If Auto Link Protocol is set to Telnet or Rlogin the CN2600 will connect to the host automatically using the specified protocol Primary and Secondary host address If specified the fields designate permanent hosts to which the terminal will always be connected Telnet TCP port default 23 By default the Telnet TCP port number is set to 23 which is the default TCP port number for Telnet Terminal type default ansi Some older terminal applications may require that the terminal type be transmitted before the connection can be established You
175. ting to a Serial Device Connecting to the Console Port Adjustable Pull High Low Resistors for the RS 485 Port O 00 00 0000 CN2600 Series Hardware Installation Desktop Place your CN2600 on a clean flat well ventilated desktop For better ventilation attach the 4 pads from the desktop kit to the bottom of the unit and leave some space between the CN2600 and other equipment Do not place equipment or objects on top of the unit as this might damage the server Bottom of CN2610 lo A Rackmount The CN2600 is designed to be mounted on a standard 19 inch rack Use the enclosed pair of L shaped metal brackets and screws to fasten your CN2600 to the rack cabinet Each L shaped bracket has 6 holes leaving two outer or inner holes available for other uses You have two options You can lock either the front or rear panel of the CN2600 to the front of the rack Locking the front panel is shown in the following figure L Shaped Metal Bracket A mer here NT O ZZ 2 SU m L AXLLIITIITITTIMSEUE Wiring Requirements NOTE ATTENTI ON Safety First Be sure to disconnect the power cord before installing and or wiring your CN2600 Wiring Caution Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your
176. to establish a TCP IP connection When the user wants to visit a particular website the user s computer sends the domain name e g www moxa com to a DNS server to request that website s numeric IP address When the IP address is received from the DNS server the user s computer uses that information to connect to the website s web server The CN2600 will play the role of a DNS client in the sense that it will actively query the DNS server for the IP address associated with a particular domain name The following functions on the CN2600 web console support the use of domain names in place of IP addresses Time Server Destination IP Address in TCP Client mode Mail Server SNMP Trap Server Destination Address in Pair Connection mode Primary Secondary Host Address in Terminal mode RADIUS Server and SMTP Server DNS server 2 This is an optional field The IP address of another DNS server may be entered in this field for times when DNS server 1 is unavailable 5 7 CN2600 Series Configuration with the Web Console PPPoE user account and PPPoE password For dynamic broadband networks such as xDSL or cable modem users must enter the username and password that they received from their ISP to establish network connection If a serial port on the CN2600 will be using PPPoE enter the account name and password in these fields WINS function default enable Enable or disable the WINS Windows Internet Naming Service server WI NS server I
177. to re open your application software s COM port for data to transmit properly 4 4 CN2600 Series Serial Port Operation Modes Dual host Redundant Data Acquisition System DRDAS NOTE Primary PC Backup PC LANA ri LAN B Primary ilies RS 232 422 485 Data A ota Eb xe Remote Terminal Unit RTU The DRDAS operation mode provides a highly redundant network structure that takes advantage of the CN2600 s dual LAN ports dual IP addresses and dual MAC addresses DRDAS uses a backup PC that is set up to take over when the primary PC fails The CN2600 s dual host redundant configuration sends serial data to 4 IP addresses on the network Users select a Primary IP and 3 Secondary IPs When the Primary IP fails the backup IPs take over by using the DRDAS library The DRDAS library is used to configure the DRDAS of the CN series You must use the DRDAS library to designate the primary and secondary hosts If you need this library please contact conn support moxa com With this kind of redundant setup if one of the secondary IPs tries to send commands to the serial device the commands are discarded by the CN2600 since only the Primary IP is allowed to conduct bi directional transmission The backup IPs are only allowed to receive data from the CN2600 The RS 232 connector on the Remote Terminal Unit RTU shown above must be set up with an RS 232 to RS 422 485 converter such as the Moxa TCC 100I to conv
178. transmitted before the connection can be established You may need to refer to the server s documentation to determine the appropriate terminal type For most applications this setting will be unnecessary and will have no effect Quit defaultz E 0x05 This field configures the quick key used to disconnect the link between the current terminal session and the remote host It is not necessary for binary communication Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description Local Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Auto login prompt default ogin Password prompt default assword Login user name Enter the terminal login ID here Login password Enter the password for the terminal login here 6 20 CN2600 Series Configuring Serial Port Operation Modes Reverse Terminal Total Solution for Industrial Device Networking 243 Serial Port Settings B operation Meadas 33 Porti 1 Operation Modes Horus gj Communication Parameters m 403 Burana eG Application Reverse Terminal y Hall Modem Settings Mode Reverse Telnet y CJ Cipher Settings TCP alive check time 7 0 99 min HE Port 2 Inactivity time lo 0 99 min Sl Por
179. ut only when the internal buffer is full or as specified by the force transmit time When set to 0 the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a Series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 17 CN2600 Series Configuring Serial Port Operation Modes Terminal Applications Terminal ASCII TERM_ ASC MOXA J Main Menu E 1 CJ Overview Basic Settings 9 Network Settings 3 Serial Port Settin
180. uto disconnection A setting of O ms will cause the port to remain connected even if idle Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off 6 24 CN2600 Series SLIPD Mode Configuring Serial Port Operation Modes Total Solution for Industrial Device Networking 3 Main Menu Q3 Overview 2 Basic Settings Operation Modes HQ Network Settings Port 1 EI Serial Port Settings Application Dial infout v EMEN Port 1 Mode SLIPD vw 3 Operation Modes 3 Communication P 2 Data Buffering Lo C3 Modem Settings CJ System Management 9 System Monitoring 2 Save Configuration CJ Restart H A lt lv ES Destination IP address Source IP address IP netmask TCP IP compression O Enable Disable Hg Port 2 HG Port 3 Inactivity time o ko 65535 ms E Port 4 Disconnect by None Hg Ports P1 P2 Op3 Op4 Ops Dre Or Firs HG Port6 Apply the above settings to DAI ports Eg Port 7 EC Ports CJ welcome Message SLIPD SLIP on demand is used for dial in services since it provides SLIP services only when receiving a request from a remote PC Destination I P address This is the IP address of the remote dial in dial out server Source IP address The Source IP address i
181. vers and collects accounting information about remote connections Do you want to set up this remate access server to use an existing RADIUS server C Mo don t want to set up this server to use RADIUS now Yes want to use a RADIUS server Windows provides a RADIUS solution called Internet Authentication Service 145 as an optional component that you can install through Add Remove Programs z Back L ancel Start e 5 i Routing and Remote A EE 2 12 PM Setting up Windows 2003 Hosts Windows 2003 uses the IAS service instead of the RADIUS service For this reason you need to install the IAS service to use RADIUS with Windows 2003 The IAS service will not be installed by default 1 Open Start gt Add or Remove Programs gt Add Remove Windows Components 2 With Windows Components selected choose Networking Services CN2600 Series RADIUS Server Windows Components Wizard Windows Components You can add or remove components of Windows To add or remove a component click the checkbox A shaded box means that only part of the component will be installed To see what s included in a component click Details Components O 9 Management and M onitoring Tools Wi ES SEPA a Remote Installation Services 2 0 MB 1 E Remte Storane 34h MB hd p Description Contains a variety of specialised nebwark related services and protocols Total disk space required
182. w ra Basic Settings i No Gateway Destination Netmask Metric Iface Network Settings i E 1 203 67 6 254 210 48 96 9 ret 2 lanl EC Serial Port Settings ES System Management 1 lani Y ES Misc Network Settings 3 1 lani Y E E ra Accessible IP List 4 1 lanl GI SNMP Agent E i cm a aue 6 1 lani Host Table a Route Table 7 1 lani i i ra User Table 8 1 lani Y i fa Authentication Serve 9 1 lani E i d System Log Settings 10 1 lanl Y m Auto Warning Settings rr F nz g HH Maintenance 0 a Certificate s i lani o ne System Monitoring 13 1 lani Y ra Save Configuration 14 1 lani H Restart 15 1 lani Y 16 1 lani T a 17 1 lani M 5 11 CN2600 Series Configuration with the Web Console Configuring Multiple Point Routes A Web FTP A E mail News A P Server A Server Ethernet 203 67 6 TCP IP CN2600 203 67 6 253 das 9 Router 203 67 6 254 Modem 1 gt 5 Modem 2 Internet Modem3 Modem 4 202 6 8 254 AA aan 201 2 2 254 Series ri Printer L f MRP Printer f MRP EL Server h i Server 202 6 6 3 2 201 2 2 1 Phone Line Phone Line Ethernet Ethernet 20266 E 201 2 2 PC PC PC PC For multi location enterprises CN2600
183. ware Installation Configuration eeeeeiieseeeeeuuannne eu ua aane rn nana ran uan rreuu uua u uua 9 1 NPORESSGareh WC Vesscelelils Oli A leet A A A TA lou 00 9 2 Installing NPort Search UCI sr RR ERR EE ER RIEN ED RE Y ERU Re ye v eee E RR EE Ha ee Eee 9 2 Cohtiguand NPOIGS earem UTY aroaro re ata seen Fue aho eee ehe euh rates vee alee sales Fe va habs eater attese tava tester hentia 9 4 WINdoOWs Driver Mana der cia igo fee tritt tec fatto at ftc E e cR M Mu taa 9 5 Installing NPort Windows Driver Manager ssssssssssssssseee nme nme nsns heme 9 5 Using NPort Windows Driver Manager ssssssssssssss nee hme EEE ed DDE EEE ES rr 9 7 Wirndows Mohltor U EIE es amma ea URDU RD MD DEDERE DM MM DRM DEDE EM REDI RD RUD SUE 9 14 I astalling thedNPoOFE Monitor UTM e oo ooo Ope o OE O ERO A ENE 9 14 Using the NPorte Monitor UEITID eas oi iste to tetti otii e e de base 9 16 Eau REA EE ORIVE E E T MTM 9 17 Basic Phocedul CS ataud sete iron P3 PO duty 8 308 2 2n d Indu 93 bedded D 38 08 2 iia dela ivan dite Dura nou Dno d dn Me Mr aere f 9 17 Bice ic goths ciu io HERRERA E 9 18 Iaseallirigebimuxieal nh PE DINE PIS taa 9 18 Mapping TIY POES EE IUIUS 9 18 Disce M le e mE ea 9 18 Mapping TTY Ports Automatically cccccccc cece eee eee eee ehem mens 9 19 Mapping Many Pores MS 9 19 REGUN Mme O note tara 9 19 MADD EPON Sasain ae E 9 19 Removing Mapped TEY POr Estancia cee a ee ries Coen
184. with the following default private IP addresses 192 168 126 254 and 192 168 127 254 Note that IP addresses that begin with 192 168 are referred to as private IP addresses Devices configured with a private IP address are not directly accessible from a public network For example you would not be able to ping a device with a private IP address from an outside Internet connection If your application requires sending data over a public network such as the Internet your CN2600 will need a valid public IP address which can be leased from a local ISP Configuration Options Terminal Server Search Utility You may configure your CN2600 with the bundled NPort Search Utility for Windows Please refer to Chapter 9 Software Installation Configuration for details on how to install and use Terminal Server Search Utility Web Console You may configure your CN2600 using a standard web browser Please refer to Chapter 5 Configuration with the Web console for details on how to access and use the CN2600 web console LCM Console Front Panel The CN2600 only gives you the option to configure some settings through the front panel also known as the LCM Liquid Crystal Module console The LCM console can be configured for read only or writeable access Read only access allows settings to be viewed but not changed Factory default settings are for writeable access where configuration is allowed through the LCM console NOTE The wide temperature model
185. you can set up the CN2600 s serial ports as remote COM ports for your PC host Be sure the Serial port s on your CN2600 are set to Redundant COM mode when using NPort Windows Driver Manager to map COM ports 1 Goto Start gt CN2600 series Windows Driver Manager gt CN2600 series Windows Driver Manager to start the COM mapping utility 2 Click the Add icon e NPort Windows Driver Manager O x File COM Mapping View Help Bu gh amp El E Add Remove Apply Linda Setting Exit COM Pat IP Address 1 IP Address 2 CN2600 Series Software I nstallation Configuration Click Rescan to search for CN2600 terminal servers From the list that is generated select the server that COM ports will be mapped to and then click OK Add Nort E appina Redundant COM Alternatively you can select Input Manually and then manually enter the CN2600 s IP Address 1st Data Port 1st Command Port and Total Ports for the COM ports that will be mapped to Click OK to proceed to the next step Note that the Add NPort page supports FQDN Fully Qualified Domain Name in which case the IP address will be filled in automatically Add NPort 192 168 127 254 182 168 128254 1 9 8 CN2600 Series Software I nstallation Configuration 4 COM ports and their mappings will appear in blue until they are activated Activating the COM ports saves the information in the host system registry and makes the COM port available for u
Download Pdf Manuals
Related Search
Related Contents
HP Officejet Pro X476dw (CN461A) – Especificaciones Smithco Vacuum Cleaner 48-000 User's Manual Jet Tools JWCS-10 User's Manual Brochure - Geomesure MAM MAP1 Anleitung Page 1 Leggere il presente manuale di istruzioni prima di usare la 新製品のご案内 取扱説明書(PDF : 1.5MB) Samsung HT-D330 Benutzerhandbuch プロトコール Copyright © All rights reserved.