1. DNS This page gives detailed information for the various FRU dg SEa mare LDAP E Directory Mouse Mode Basic Information FRU Device ID Network FRI ice Ni U Device Name Network Bond Server Information Chassis Type Product Name Product Manufacturer Name Product Part Number System and Audit Log Product Version Users Product Serial Number Virtual Media ha Product Asset Tag lt gt Configuration menu is shown in picture above The following will introduce the commonly used menus Mouse Mode menu set mouse mode Set Mode to Absolute Recommended when server OS is Windows the absolute mode mouse can switch freely between remote picture and local picture Set Mode to Relative Recommended when server OS is Linux the relative mode mouse can switch between remote picture and local picture by selecting AIt M Network menu set network Please change IP address or select DHCP according to needs 3 NTP menu set date and time to be synchronous with time server or set at will If the remote management needs to choose time server to be synchronization please input address of time synchronization server Remote Session menu set KVM or data to be encrypted or not during the next redirection as well as the loading method of virtual media SMTP menu set SMTP server s IP address as well as user name and Chapter 6 Management Functions Introduction of Integrated management Card
2. Restart the software clear up system memory and restart the operating system Ctrl Alt Del Clear up system memory self check the POST again and restart the operating system Reset button Cold boot again switch off and restart the system power so that to clear up the system memory to self check the POST again to restart the operating system and Power button to power up all peripherals again 5 2 Problems When Starting the Machine Some problems often occur when the machine is started generally due to incorrect hardware installation and configuration You may find and solve the problems by the following methods 5 2 1 System Can Not Be Powered on After pressing the power button the power light is not on and the system stays in non electric state Please try the following steps 1 Check whether your power socket can supply power normally and the power cable is correctly connected 2 Repeatedly press the power button to start the machine pay attention not to exerting too much force 3 Disconnect the power cable from the system and open the chassis to check Chapter 5 Common Problems and Trouble shooting 4 Check the fastness of the cable connection and accessory plugging in the chassis 5 Remove other external components other than Inspur s 6 Pack the chassis connect the power cable correctly and start the machine 5 2 2 Monitor Has No Display The server can be powered on the host can start an
3. password User menu set user And be able to add edit and remove users The username should start with English letters and have a character size within 4 32 and a password of at least 8 characters size 5 Remote Control menu admin Admin J C Refresh Print Logout C WEFT HI Dashboard FRU Information Server Health Configuration Remote Control Maintenance ELP Console Redirection Console Redirection Server Power Control Press the button to launch the redirection console and manage the server remotely Java Console v This function menu allows you to perform various remote operations on the server including operating remote console system switch and other control operations Console Redirection menu log in console After choosing this menu and click Java Console button the system will log in remote desktop When using if prompted to install Jviewer browser please install according to the prompt Notes If external graphics card is used it is unable to use the Java Console button to log into the console A Remote desktop Video menu Keyboarc Mouse Options Media Keyboard Layo Video Recor Power Active User Help Zoom Size 110 octane DIGS oO aa Resume Redirection Refresh Video AILE Compression Mode DCT Quantization Table I Host Video Output O Full Screen Function Pause Redirection Pause remote desktop display Resume Redirection Resu
4. For more notices of our products please refer to the FAQ for server in the official website of Inspur http www inspur com support Channel_ Home support_sv asp 5 5 Technical Support Information During your using Inspur server if there s any doubt or problem please adopt the following solutions Chapter 5 Common Problems and Trouble shooting 1 If you have any doubt on product configuration and detailed specification please contact your supplier 2 If there s any system problem occurred during your using the machine please contact Inspur server customer service center directly Please record the product serial number on your host chasis Our technical support personnel will provide you solutions or carry out onsite repair after receiving your request 3 Contact information of Inspur server customer service center Email sv_str_pcs inspur com Inspur server dirvers and product information download link http www inspur com support Channel_Home support_sv asp Chapter 6 Management Functions Introduction of Integrated management Card This product integrates IPMI management card by which the user can remote log in the server The following will describe the application of management function that management controller integrates 6 1 Management Chip BMC IP Onboard IPMI management card IP can be checked and set in the menu of Server Mgmt BMC network configuration BMC Sharelink Management Channel
5. 2 Product Introduction SS Physical dimensions Package box outer size W Width 664mm H Height 443mm D Depth 963mm Main chassis size W Width 448mm H Height 177 mm D Depth 751mm Standard configuration 2 CPUs 4 DIMMs 4 SAS HDDs 3 power module Net weight 38Kg Gross weight 47Kg packaging guide rail Full configuration 4 CPUs 32 DIMMs 16 SAS HDDs 4 power modules Net weight 42Kg Gross weight 51Kg packaging guide rail Environment parameter Operating environment temperature pee Storage and transport temperature meee Operating humidity 35 80 relative humidity Storage and transport oZ 0 i idi humidity 20 93 40 C relative humidity 2 2 Front Panel View The pictures are for reference only please refer to your actual machines 4 5678910 11 12 13 14 15 16 1718 19 20 21 Front panel view Name Chapter 2 Product Introduction Introduction Network card 4 indicator light Integrated 1350 network card 4 indicator light Blinking network connected or transferring data green Off no network connection Network card 3 indicator light Integrated 1350 network card 3 indicator light Blinking network connected or transferring data green Off no network connection Network card 2 indicator light Network card 1 indicator light Fan module plane Integrated 1350 network card 2 indicator light Blinking network connected
6. BMC Dedicated Management Channel Station IP address in the BIOS Ai Notes BMC Sharelink Management Channel refers to the multiplex management network interface onboard Intel 1350 network card 3 BMC Dedicated Management Channel refers to IPMI management dedicated interface Please set or view IP address according to the actual use of the network card If you reset IP address of IPMI card only after saving and restarting the server or powering off disconnecting the power can you make it into normal use 6 2 Remote Login 1 Remote Client System Requirements The requirements of remote client system of GUI interface connecting to the server management chip through web browser are shown in the following table Requirements Remote web control panel client Support the operation system of Microsoft Internet Explorer ration system Oper tor syste browser Install Java SE Runtime Environment 6 Update 12 or higher Browser plug in module version TCP IP network protocol stack Support TCP IP network protocol stack The download address of browser plug in module Java SE Runtime Environment http www java com en download You can use Inspur driver CD to get and install browser plug in module enter Chapter 6 Management Functions Introduction of Integrated management Card the java directory in the CD root directory here is the Java SE Runtime Environment 6 Update 18 plug in module based on W
7. Postcode 250101 Contents Chapter One Safety Information 0 0cccccccccssceesseeeeeeseceeeeneeeeseneneeesseeeseeenes 1 Chapter Two Product Introduction 0 0 cc ececccesccesecenecneceseeeseeeaeeeeeeaeeeaeeeaeeeaees 6 2 1 Server Technical Specificatii ssvsvssevasvesasvustasssvsvdeseivavien vas cusedeavvaxesanevsnvesveene 6 22 Front Panel VICW shies ee a E I ERN E 8 2o Rew Panel VEW oponiunocu nnn Ranai SETE 10 Chapter 3 System Setup ccccccccesscessecesseeeseeesseeesseecseeceseeeseeeeseseneaeeseeeeneeenes 13 3 AS yStem BIOS Setup eicces eieren e aa E ae EE EE EN EES 13 3 2 Motherboard Jumper Settings 0 cccccccccsecesecesseeeeseeeseeceseeeeeeeseseeseeeeneeenes 23 Chapter 4 Install Operating System 0 ccccccccccceeseeseecseeeeseeeeeseeeseeeseeeseeenes 26 4 1 Application Instructions for Inspur Driver U disk ce eeeeseeseeereeeeeeeneees 26 4 2 Manually Install Windows Server 2008 R2 uu eeceeseseeeeeeeeeeeceeeeeeeeeeeeaeess 31 4 3 Manually Install Red Hat Enterprise Linux 6 1 0 eeceeceeeseeeteeeeeeeeeneeeneees 35 Chapter 5 Common Problems And Trouble Shooting cccecceseeseeneeeees 40 S ORGS tartin amp Servers se aeces coos a E E rare tnsa as 40 5 2 Problems When Starting the Machine escesseesceseeeeeeeeeeeeeeeeeeneeeneeeneeeaes 40 5 3 Problems about Attached Ruijie Server Suite oo eeeeeseeseeteeneeeseeeneeeaes 43 SA Additional N Ot6S wsiivscicdissivcsiags
8. RAID controller Oprom and EFI driver including Enabled enable or disable integrated SATA RAID controller Oprom and EFI driver Disabled disable integrated SATA RAID controller ROM and EFI driver Legacy Option ROM default setting set to traditional Option ROM e ME Subsystem This menu is used to set ME subsystem ME Subsystem This menu is used to enable or disable ME subsystem When set to Enabled default setting it can view ME related information 4 Server Mgmt menu e Wait For BMC This item is used to set up whether waiting for BMC startup or not including Enabled and Disabled default setting two items e System Event Log This menu is used to set the features of system event log Modification in this menu can take effect only after the computer restarts SEL Components This item is used to set whether the system shall record all the logs when the system starts including Enabled and Disabled default setting two items If it is set to be Enabled the user can also set the log clear method and other configurations Erasing SEL This item is used to configure the method of log erasing including No default setting not to erase log Chapter 3 System Setup Ll SS Yes On next reset erase log on next reset Yes On every reset erase log on every reset When SEL is Full This option is used to set the approach when event logs are full including two options Do Nothing d
9. continue 11 The system enters the interface of Where do you want to install Windows It will display the existing disk partitions and unallocated spaces on the computer You can conduct the following operations by clicking Drive options It can delete the existing partitions by selecting the existing partitions and then clicking Delete It can format the partitions by selecting the existing partitions and clicking Format It can create new partitions by selecting unallocated disk spaces and then clicking New to create new partitions You can operate according to the actual demands Here we d expound on the issue when there are no existing partitions in the disk 1 Select the unallocated space click New delete the number in the Size input box then input the one you want to create unit MB and click Apply to continue If the confirmation window pops up click OK to continue Notes We suggest the partition should be larger than 30GB 2 Select the newly created disk partition then click Format and click OK at the prompt confirmation interface GD Chapter 4 Install Operating System o 3 After formatting the partition click Next to continue 12 The system starts to install Windows and it will complete operations of Copying files Expanding Windows files Installing features Installing updates and Completing installation etc In this course the system may aut
10. from the CD 2 The system enters the interface of Welcome to Red Hat Enterprise Linux 6 11 This includes the following items Install or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local driver You can use up and down arrow key to select items Here we default that this is the first installation Select Install or upgrade an existing system and press Enter to GD Chapter 4 Install Operating System continue installation 3 The system prompts Disc Found To begin testing the media before installation press OK Choose Skip to skip the media test and start the installation Here select Skip to skip the disk detection and press Enter to continue the installation 4 The installation program goes to RED HAT ENTERPRISE LINUX 6 interface click Next to continue the installation 5 The installation program goes to What language would you like to use during the installation process interface Select to install language version of the operating system Here we select English English for installation and click Next to continue 6 The installation program enters Select the appropriate keyboard for the system interface Please select keyboard type according to actual situation Here we select U S English and click Next to continue the installation 7 The installation program goes to What type of devices will your installation
11. involve Basic Storage Devices Installs or upgrades to typical type of storage devices If you re not sure which option is right for you This is probably it Specialized Storage Devices Installs or upgrades to enterprise devices such as Storage Area Networks SANs This option will allow you to add Foe Ischia Zech disks and to filter out devices the installer should ignore Here we select Basic Storage Device and click Next to continue the installation 8 The system enters Please name this computer The hostname identifies the computer on a network Please input the Hostname Here we also can select Configure Network on the left bottom of the window to configure the network You can add or delete the network card to configure the network IP address After finishing the network configuration click Next to continue the installation 9 The installation program goes to the time zone selection interface Please select the nearest city in your time zone Select Asia shanghai and then click Next to continue the installation Chapter 4 Install Operating System 10 The installation program enters Root Password setting interface set at least six figures as needed and click Next to continue the installation The root account is used for administering the system Enter a password for the root user 11 The installation program enters Which type of installation would you like This is the installation select
12. or transferring data green Off no network connection Integrated 1350 network card 1 indicator light Blinking network connected or transferring data green Off no network connection Open the fan module plane and there are 4 fan modules Every fan module contains 2 fans and it is Fan 1 which is close to the motherboard side Seen from chassis front view the fan module is 1 2 3 4 from left to right in turn There are FAN1 FAN2 indicator lights on each fan module when fan failure occurs the light is orange Fan failure indicator light Fan failure alert On fan fails orange color Off fan is working normally System failure indicator light System failure alert On system fails orange color Off system is working normally Reset button System restart button ID button and indicator light When server is connected to power press ID button on chassis front side or ID button on chassis back side and this light will turn blue for server identification repress the button and the light will turn off Power button and indicator light Power on off button and power up indicator light On the server is powered up Off the server is not powered up Left handle Chassis handle on the left HDD active state indicator light 1 8 2 5 HDD bays Turn green when the hard disk is reading and writing HDDs supported by SAS module 1 and HDD0 HDD7 from left to right in turn Chapter 2 Pr
13. slot PCIE bus type PCI Express bus supporting vertically inserted full height expansion card PCIE slot PCIE_0 CPU0O slot internal half length full height PCIE x8 slot CPU_0 supports PCIE_1 CPUO slot full length full height PCIE x8 x1 slot CPU_0 supports PCIE _2 CPUO slot full length full height PCIE x16 slot CPU_0 supports PCIE_0 CPU1 slot full length full height PCIE x8 hot swap slot CPU_1 supports PCIE_1 CPU1 slot full length full height PCIE x8 hot swap slot CPU_1 supports PCIE 2 CPUI slot full length full height PCIE x16 slot CPU_1 supports PCIE_0 CPU2 slot internal half length full height PCIE x8 slot CPU_2 supports PCIE_3 CPU slot 10Gigabit Ethernet expansion card installation slot CPU_1 supports Hard disk Hard disk type 2 5 SAS and SATA hard disk Number Different CPU numbers configured support different hard disk number 1 2 CPU support up to 8 pieces of 2 5 HDD 4 CPUs support up to 16 pieces of 2 5 HDD External storage drive Optical drive optional Optional standard SATA optical drive no standard SATA optical drive when the hard disks number is over 8 Inspur drive U disk Power supply Optional Inspur drive U disk Load HDD controller driver when install OS manually Specification 700W power module 2 1 redundancy or 2 2 redundancy is available Power input Please refer to the power input label on the host nameplate Chapter
14. 350 network card 2 interface Integrated 1350 network card 2 interface 1350 network card 1 interface Integrated 1350 network card 1 interface 1350 network card 4 interface Integrated 1350 network card 4 interface 1350 network card 3 port Integrated 1350 network card 3 interface can be used as multiplex management interface Each network card interface has two indicator lights Indicator light on the left network card activity indicator light when network card is active the yellow light blinks Indicator light on the right network card status indicator light it is green for 100 megabit while it is orange for Gigabit Chapter 3 System Setup USB port Connecting USB port device IPMI management interface Integrated IPMI management dedicated interface USB port Connecting USB port device PCIE_2 CPUO slot PCIE x16 slot CPU_0 supports PCIE_1 CPUO slot PCIE x8 x1 slot CPU_0 supports PSU 4 installation slot Installation position for the 4th power module PSU 3 installation slot Installation position for the 3rd power module PSU 2 installation slot Installation position for the 2nd power module ID button and indicator light When server is connected to power press this ID button or ID button on chassis front side and this light will turn blue for server identification repress the button and the light will turn off PSU 1 installation slot
15. Dear User of Inspur Yingxin Server Heartfelt thank you for your use of Inspur Yingxin Server This manual introduces the technical characteristics the system installation and setup of the server to help you to fully understand and expediently use this server Please deliver the package of our product to the waste recycling station for recycling in favor of pollution prevention and humankind s benefit This manual is the property of the Inspur This User Manual is not to be copied by any group or person in any manner without the consent of Inspur The Inspur reserves the right of revising this manual momentarily Any alteration about the content of this manual will not be informed Please contact Inspur if you have any questions or advice about this manual Inspur October 2013 Inspur and Yingxin are registered trademarks of Inspur Group Co Ltd Other trademarks belong to other corresponding registered companies Statement Please read the following statements before you use this server Only when you have read this statement hereinafter and agreed the following terms you can formally use this server If you have any questions about the following terms please contact our supplier or us directly If you have no questions about these terms and start to use this server it acquiesces that you have agreed the following terms 1 We must call your attention that you must not alter any other parameters in the motherboa
16. Installation position for the 1st power module Power input interface Connecting power supply cables Each power module has a power input interface Chapter 3 System Setup In this chapter the regular jumper of motherboard and BIOS function setup of this server are introduced Only operator or administrator with qualification of system maintenance can implement these operations described in this part 3 1 System BIOS Setup BIOS is a basic input and output system With some special setting programs it can adjust the system parameter and the hardware parameter As BIOS has great influence on the starting and running of the system setting parameters improperly may arise the conflict among hardware resources or affect the system s performance Hence understanding the BIOS setup is significant to server configuration If there is no especial requirement we suggest you use the default value and not alter the parameters Pn Notes 1 Before the server BIOS setup is altered please record the corresponding original setup Hence when there are operating problems in the system due to the alteration the setup can be restored 2 The factory default system setup is usually the optimized setup Don t try to alter the parameters before you understand their denotations 3 The common setup is introduced in detail in this chapter For items less used in the application this chapter only offers simple instruction or just omits the instr
17. OS setup progress Otherwise some administrator right will be limited e User Password This menu is used to set up user password After the setup of the user password you must input the password when booting and entering the BIOS setup progress In the setup interface of BIOS Setup you have the same authority with the administrator after entering the password 7 Save amp Exit menu The options in this menu can be used to save or discard the settings of the changes in the BIOS and exit the setting program e Save Changes and Exit Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be saved and the system will exit the BIOS setup The menu function can use F10 shortcut key to realize e Discard Changes and Exit Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will exit the BIOS setup e Save Changes and Reset Select this item and press Enter After you select Yes for confirmation the QD Chapter 3 System Setup O changes in the BIOS settings will be saved and then the server will be rebooted e Discard Changes and Reset Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and then the server will be rebooted e Saving Changes Select this item and press Enter After you select Yes for confirm
18. Power Cycle Server Select this option to power cycle server Chapter 6 Management Functions Introduction of Integrated management Card I Remote desktop Active User Click Active User menu to view the user name and IP address of the remote login currently J Remote desktop Help menu Click Help menu A drop down menu About JViewer appears Select this option and redirection browser version will display 2 Server Power Control Menu Select Server Power Control menu and enter the interface shown in the following figure Wadmin Administrato Dashboard FRU Information Server Health Configuration Remote Control Maintenance Power Control and Status A The current server power status is shown below To perform a power control operation select one ofthe options below and press Perform Action Host is currently on Reset Server O Power Off Server Immediate O Power Off Server Orderly Shutdown Power On Server O Power Cycle Server Perform Action v Server Power Control menu displays the current power state of server providing reset server power off server immediately power off server orderly power on server and power cycle server After selecting the option to execute click Perform Action to execute 6 Maintenance menu SadmiN Admin E Refresh 2 Print Cogout Sees Dashboard FRU Informat
19. ate problems according to the following methods 5 3 1 Prompt Unable to Get the Disk Size When Using Reijie to Guide System Installation Please check whether the local hard disk and RAID are normal 1 Onboard RAID configuration it s need to confirm whether RAID mode under BIOS is enabled 2 Offboard RAID configuration please confirm whether RAID array is configured Chapter 5 Common Problems and Trouble shooting 5 3 2 The Disk Size and Local Disk Capacity Are Inconsistent When Using Reijie to Guide System Installation Please check whether there are external mobile devices USB device external disk array tape library and so on If the server is connected with USB flash drive USB softdog mobile HDD or other USB devices please remove them first and then install the system if the server is connected with storage devices please disconnect the storage devices and then use Reijie to install otherwise it may cause storage array abnormity and data lost 5 3 3 The Machine Auto Reboots Repeatedly after Inserting System CD When Reijie Boot Configuration Is Finished 1 Reijie CD system installation is developed based on genuine system CD directory structure so if you use all in one system CD please change to use a single system CD to install 2 When Reijie boot configuration is finished please operate according to Reijie boot prompt If there is not prompt to insert system CD please don t insert the system CD into CD drive
20. ation Server Health Configuration Remote Control and Maintenance Chapter 6 Management Functions Introduction of Integrated management Card In the upper right corner of the interface are user login name and user group displayed where the login user is And the user can use shortcut menus such as Refresh Refresh page Print print page Logout cancellation simplified Chinese language switching etc 1 Dashboard menu In this menu the information of management chip Firmware version modification time and MAC address etc can be viewed Click Edit button behind Network Information to enter network settings interface And set IP address and gateway as well as other information Click Launch behind Remote Control to log in console When using if prompted to install Jviewer browser please install according to the prompt Notes If external graphics card is used it is unable to use the Launch button to log into the console 2 FRU Information menu This menu displays FRU Information including Basic Information and Server Information two parts Basic Information shows ID number and names of FRU device Server Information displays server whole machine s type name manufacturer and other information Following are the detailed information admin Administrat Refresh A Print Logout see Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP i z A Field Replaceab
21. ation the changes in the BIOS settings will be saved and the system will not exit the BIOS setup e Discard Changes Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will not exit the BIOS setup e Restore Defaults Select this item and press Enter After you select Yes for confirmation the system will load system default optimization setup and the system will not exit the BIOS setup This menu function can use F9 shortcut key to realize e Save as User Defaults Select this item and press Enter After you select Yes for confirmation the system will save the current items setup values of the BIOS as the user default value e Restore User Defaults Select this item and press Enter After you select Yes for confirmation the system will load the already saved user defaults e Boot Override Select the device item of this menu After you select Enter for confirmation then it will boot system from the selected device 3 2 Motherboard Jumper Settings Motherboard jumper setting is the operation of shorting cut two pins of the jumper to change the interface functions Refer to the following figure and adjust the motherboard functions Chapter 3 System Setup ll Ce Connector ae n Jumper Cap 3 2 4 Setting Pin 1 2 short Figure of jumper settings 3 2 1 Open the Chassis Upper Panel If the following operations are nee
22. ces are not connected USB3 0 Support This item is used to set whether to support USB3 0 including Enabled default setting and Disabled two items 3 Chipset menu e CPU Advanced Settings This menu is used to set IOH and QPI related information as well as memory related items IOH Configuration This menu can set IOH related information and PCIE interface speed A Intel R 0AT This item is used to enable or disenable Intel I O acceleration technology including Enabled and Disabled default setting two items Chapter 3 System Setup E A VGA Priority This item is used to set priority order of onboard graphic card and external graphic card including Offboard default setting external graphic card has the priority for use Onboard onboard graphic card has the priority for use QPI Configuration The submenu of this menu is used to set QPI speed mode frequency and others If it is single CPU configured QPI Link Speed Mode item is set to Fast and Current QPI Link Speed item actually displays Slow state Memory Mode Memory mode setup includes four options Independent Mirroring Lock Step and Sparing If the system memory configuration supports Mirroring and Sparing the two function modes status displayed above this configuration item should be Supported otherwise the status should be Not Possible To realize Mirroring function it must be in the first chann
23. d run normally but the monitor doesn t work 1 Check the correctness and fastness of the signal cable and power cable connected to the monitor 2 Make sure to power on the display 3 Adjust the contrast and brightness of the monitor to confirm whether it can display or not 4 Shut down the system and disconnect the power cable to check whether there is curve in the pin at the connecting end of the monitor signal cable and the host 5 Find another monitor for test if possible 6 If the machine is installed with components other than Inspur ones please remove them first 7 With the permission of Inspur technical support personnel you may pull and plug RAM and clear CMOS for test 5 2 3 Installation System Can t Find Hard Disk 1 When installing the system directly booted with the system CD if it prompts that no hard disk can be found please check the normality of the disk state and power on self check hard disk state 2 If the power on self check can detect the hard disk but the hard disk can t be detected when installing the system it may be caused by the following conditions e If you are using the system CD to boot and install the operating system directly the hard disk drive is generally added through the floppy driver or Inspur driver U disk When using USB floppy driver to add the drive please set the BIOS first and close the onboard floppy driver controller When using Inspur driver U disk to add the drive plea
24. ded please get the authorization of Inspur according to the methods as follows to open the chassis upper panel 1 Power off the system turn off the AC power 2 Vertically press the PUSH button on the chassis upper panel with two thumbs and meanwhile push the chassis upper panel backwards 3 Remove the chassis upper panel Open the chassis upper panel Chapter 3 System Setup O Following is the layout of common motherboard jumper C les POES Motherboard common use jumper location picture Jumper name Function description Jumper function CLR_CMOS jumper CMOS jumper Short cutting pinl and 2 normal state default Short cutting pin2 and 3 clear CMOS J77 jumper Integrated 1350 network card 3 jumper Short cutting pinl and 2 enable network card default Short cutting pin2 and 3 disenable network card J78 jumper J79 jumper Integrated 1350 network card 4 jumper Integrated 1350 network card 1 jumper Short cutting pinl and 2 enable network card default Short cutting pin2 and 3 disenable network card Short cutting pinl and 2 enable network card default Short cutting pin2 and 3 disenable network card J80 jumper Notes Integrated 1350 network card 2 jumper Short cutting pinl and 2 enable network card default Short cutting pin2 and 3 disenable network card 1 When clearing CMOS the system mu
25. e keyboard Selecting this option will appear Hold down and Press and Release Right Windows Key It stands for press down or release Windows key on the right side of the keyboard Ctrl Alt Del Select this option equal to press Alt Ctrl Del Context Menu Shortcut menu Selecting this option can add hot keys based on actual need Notes When configuring RAID through remote console it requires the following three ways to enter the RAID configuration interface take combination keys Ctrl H for example Check Hold Left Ctrl Key option in remote desktop Keyboard menu and then click key H on the Keyboard Select key LCTRL at the lower right corner of remote desktop and then click key H on the keyboard 3 Through SoftKeyboard in remote desktop Keyboard Layout menu click CTRL H on the soft keyboard GD Chapter 6 Management Functions Introduction of Integrated management Card C Remote desktop Mouse menu Video KeyboardiMible Options Media Keyboard Layo Video Recor Power Active User Help Zoom Size 110 It reali ICI _ BE alibration Mouse Mode Menu Function Select this option to display local mouse and redirection mouse on remote Show Cursor desktop at the same time Mouse Mode Select this option to set mouse mode D Remote desktop Options menu Video Keyboarc Mous Media Keyboard Layo Video Recor Power Active User Hel
26. een It needs to follow the methods below before entering RAID card configuration interface firstly enter BIOS and then set Advanced Runtime Error Logging Runtime Error Logging Support option to Disabled After RAID card configuration is completed set this option to Enabled 5 Instruction for SATA Mode option settings when installing some operating systems When installing Suse Linux 11 1 operating systems and if using standard SATA optical drive for installing operating system it needs entering BIOS and setting Advanced SATA Configuration SATA Mode option to AHCI Mode so as to support optical drive to install operating system 6 Instructions of hot swap PCIE slots On the motherboard PCIE _0 CPU1 slot and PCIE_1 CPU1 slot are hot swappable which supports online replacement of expansion card When hot swappable slot is configured with expansion card and if the indicator light is normally on the expansion card in this slot works normally If it needs to online replace the expansion card in this slot press the switch of this hot swappable slot And then replace the expansion card in this slot after the indicator light is off After the replacement is completed again press the switch of the hot swappable slot After the indicator light is normally on the expansion card works normally Some PCIE expansion card cannot support hot swapping operation very well For details please consult Inspur customer service center 7
27. efault setting do nothing about log Erase Immediately erase log immediately e BMC network configuration This menu is used to set up the configuration information of BMC network interface Sharelink Network This item is used to set whether to enable multiplex management interface including Enabled default setting and Disabled two items BMC Sharelink Management Channel Related items of this menu can be used to setup the access method to network card IP address when Intel 1350 network card 3rd works as multiplex management interface When it is set to Static the user has to manually set the information such as IP address subnet mask and router IP address When it is set to Dynamic default setting the user does not need to set the previous items BMC Dedicated Management Channel Related items of this menu can be used to setup the IP address access method of IPMI management dedicated interface When it is set to Static the user has to manually set the information such as IP address subnet mask and router IP address When it is set to Dynamic default setting the user does not need to set the previous items User Configuration The options under this menu are used to set remote login IPMI management interface user name user permissions whether the user name can be used and whether user password can be changed etc A User ID set user group including five options Select Admin User1 User2 a
28. el and the second channel or the third channel and the fourth channel of the same CPU Besides the memory configuration in the two channels must be the same i e both the channels have been configured 1 memory chip or 2 memory chips To realize Sparing function when more than 1 memory chips are configured in the same channel it can realize this function DDR Speed This item is used to set DDR speed If the system is configured with 4Rank memory of DDR3 1066 1333MHz and it is full configuration for memory the system Memory Speed will be limited to 8300MHz and Force DDR3 1066 1333 will not function DIMM Information This menu can view system memory installation DIMMs and memory capacity e PCH Display and setup of PCH chip related information SMBus Controller This item is used to enable or disable system bus controller including Enabled default setting and Disabled two items Restore AC Power Loss Chapter 3 System Setup O Set status of power supply again after the system powers off abnormally including Power off default setting is shutdown status which needs to start up manually Last State is the status before power down Power on is the startup status Disable SCU devices This item is used to enable or disable integrated SCU controller including Enabled default setting and Disabled two items Onboard SATA RAID Oprom Driver This item is used to enable or disable integrated SATA
29. elcome to use Inspur driver CD window input the navigation code on the driver CD case or select machine type for the specific type please check the host nameplate tag and click OK to enter the installation interface automatically 2 In Select OS column select Windows 2008 R2 3 In Select Hardware column select Chipset patch 4 Click Next to start the installation 5 Enter the interface of Welcome to the Setup Program and click Next to continue the installation 6 Enter the interface of License Agreement and select Yes to continue the GD Chapter 4 Install Operating System installation 7 Enter the interface of Readme File Information and click Next to continue the installation 8 The installation program begins to install and click Next according to the prompts 9 Complete the installation click Finish according to the prompts take out the driver CD and restart the system 17 Install Network card driver 1 Insert Inspur system driver CD into the optical drive click the blue dolphin icon under the installation or operation procedure item in the automatically playing interface popped out after the disk s running Enter Welcome to use Inspur driver CD window input the navigation code on the driver CD case or select machine type for the specific type please check the host nameplate tag and click OK to enter the installation interface automatica
30. elect subfield and use keys to set field value e BIOS Information It displays the version of system BIOS and when the BIOS is altered e Memory Information It displays the system memory capacity e System Date Set the system date in format of week month day year e System Time Set the system time adopting 24 hour system in format of hour minute second e Acess Level Display user name of login BIOS Setup 2 Advanced menu This menu is mainly applied to set advanced characteristic items Improper setup can result in abnormal system operation Default configurations are recommended Following are the introductions for main and common used items e PCI Subsytem Settings This item displays PCI Bus driver version ROM priority setting enabled and disabled functions of hot plug PCIE slots 3 and 4 PCIE 0 CPU1 PCIE 3 Hotplug PCIE 0 CPU slot hot plug functions setting includes two options Enabled default setting and Disabled PCIE 1 CPU1 PCIE 4 Hotplug PCIE 1 CPUI slot hot plug functions setting includes two options Enabled default setting and Disabled e CPU Configuration Socket 0 1 2 3 CPU Configuration This menu is used to display detailed information of CPU currently installed Chapter 3 System Setup lL Se Hyper threading CPU hyper treading function setup includes Enabled default setting and Disabled two items Active Processor Cores It sets cores number of eac
31. elect the hard disk to install the system in Allowable Drives window input the size MB of the swap partition set according to the size of memory if the memory is smaller than 512MB set as twice of it If the memory exceeds 512MB you can set it as 2GB and click OK to finish the creating of swap partition You can also create other partitions as needed and click Next to continue the GD installation after the creation Chapter 4 Install Operating System 14 The system prompts window Writing storage configuration to disk The partitioning options you have selected will now be written to disk Any data on deleted or reformatted partitions will be lost Select Write changes to disk to continue installation and the system begins to format hard disk partition 15 The installation program enters Boot Loader setting interface set as needed and click Next to continue the installation 16 The system prompts The default installation of Red Hat Enterprise Linux is a basic server install You can optionally select different sets of software now Please select the type to install and the software package that needs customization according to actual demand so select Customize now and click Next to continue the installation 17 The installation program enters program package selection interface Please select according to the actual demand After confirming the selected software package to install click N
32. er is used please set this item to IDE Mode If you do not use RAID and want to connect 1 6 SATA devices when onboard Chapter 3 System Setup o D SATA controller is used please set this item to AHCI Mode Notes When installing Suse Linux 11 1 operating systems and if using standard SATA optical drive for installing operating system it needs entering BIOS and setting Advanced SATA Configuration SATA Mode option to AHCI Mode so as to support optical drive to install operating system If you want to create Intel SATA HostRAID when onboard SATA controller is used please set this item to RAID Mode This server s onboard SATA controller is only used for connecting SATA optical drive the default setting IDE Mode adopted Serial ATA Controller 0 This item can be sued only when SATA Mode option is set to IDE Mode When set to Enhanced it can support 4 SATA 3 0Gb s devices at most Serial ATA Controller 1 This item can be sued only when SATA Mode option is set to IDE Mode When set to Enhanced it can support 2 SATA 3 0Gb s devices at most e USB Configuration This menu is used to set some configuration related to USB and displays the USB devices that the system automatically examines Legacy USB Support The traditional USB devices support function setup and there are three options Enabled Disabled and Auto If set it to Auto the default does not support traditional USB devices when USB devi
33. essity Temperature if installed in the cabinet the operation and working temperature of the server can t be lower than 5 C and higher than 35 C Ventilation the cabinet used by server cluster must provide enough wind current for the front of the server to ventilate and must ensure 4100Btu heat discharge per hour The cabinet selected by the cluster and ventilation condition must correspond with requirements of the server Front and back angle rail spacing before the rails installation please adjust the space between cabinet front and back angle rail mobile rail according to the depth of the server GD Chapter 6 Management Functions Introduction of Integrated management Card 7 2 Components Needed in Server Installation Accompanying slide rail suit of 4U server includes the following objects 1 Slide rail 1 suite one for left and one for right rail 2 Fixing screw 1 wrap The rail consists of inner rail outer rail and fixed frame just as shown in picture 1 inner rail outer rail front fixed frame back fixed frame Picture 1 7 3 Installation of Inner Rail Please install the inner rail to the chassis according to the following description 1 Firstly take out the inner rail from the slide rail hold the front fixed frame of the whole slide rail and pull outward the inner rail just as shown in picture 2 Picture 2 2 When the inner rail can t be pulled any more stir the bayonet lock show
34. ext to continue the installation Here we select the Desktop and X Windows System in Desktops and Development tools software package in Development 18 The installation program begins to build file system and copy files 19 Entering Congratulations your Red Hat Enterprise Linux installation is complete interface indicates the success of installation Then click Reboot and take out the installation CD The system would reboot automatically 20 The system reboots to enter Welcome interface click Forward to continue the installation 21 The installation program enters License Agreement interface Select Yes I agree to the License Agreement and click Forward to continue the installation 22 The installation program enters Set Up Software Updates interface and click Forward to continue the installation 23 The installation program enters Create User interface Set user name and password to add user click Forward to continue the installation 24 The installation program enters Date and time interface please set the right time and date and click Forward to continue the installation 25 The installation program enters Kdump setting interface please set as needed and click Finish to finish the installation 26 Input Username and Password to log in the system Chapter 4 Install Operating System O 27 After the operating system installation it will automatically load o
35. f cabinet installation and application please pay attention to the following matters After the installation of cabinet is finished please ensure that the supporting feet have been fixed to the rack and supported to the ground and all weight of the rack have been fell onto the ground It shall install into the cabinet according to the sequences from the bottom to the top and first install the heaviest component When pulling out the components from the cabinet it shall apply force slightly to ensure the cabinet to keep balance and stabilization When pressing down the release latch of the sliding rail of components and sliding in or out please be careful as the sliding rail may hurt your figures Never make the AC power branch circuit in the cabinet overload The sum of cabinet load shall not exceed 80 of the ratings of branch circuits Ensure that components in the cabinet have good ventilation When repairing components in the cabinet never step on any other components Chapter 2 Product Introduction 2 1 Server Technical Specification Processor Processor type Intel 4 way Xeon E5 4600 series CPU Processor number 1 4 CPU Interface Socket 2011 Chipset Chipset type Intel C600 chipset Memory Memory type DDR3 ECC Registered memory Memory slot number Up to 32 DIMMs Memory capacity Support up to 256GB using single 8G memory Maximum memory capacity will i
36. frame must be guaranteed at the same level Chapter 6 Management Functions Introduction of Integrated management Card Picture 6 In picture 6 1 refers to the first hole location bearing stud 2 refers to the second hole location fixed rail screw 3 refers to the third hole location fixed rail screw 4 refers to the fourth hole location bearing stud 2 Find out the screw accompanied with slide rail picture 7 fix well the second hole picture 6 on the front and back frame corresponding to angle rail Fix well the third hole picture 6 on the back frame corresponding to angle rail Picture 7 Chapter 6 Management Functions Introduction of Integrated management Card 3 Repeat the above operation install the other slide rail to the cabinet 7 5 Install the Server to Cabinet 1 Raise the server and carry it close to the cabinet and align the back of the server with the front of the cabinet 2 Clamp the inner rail at both sides of the server into the outer rail groove of the cabinet the sliding bead of the outer rail must be moved to the front end of the outer rail 3 Refer to picture 8 keep the server horizontal and push it steadily into the cabinet If it is blocked during the pushing pull forward the bayonet lock at the front of the inner rail and at the same time push it into the cabinet Picture 8 4 Use the attached screws on left and right handles of the chassis to fix the server into the cabinet thro
37. h CPU currently installed Intel Virtualization Technology CPU virtualization tech supports function setup including Disabled and Enabled two items It is defaulted to Enabled CPU Power Management Configuration This menu enables the user to enter the CPU power management e Onboard LAN Configuration Launch PXE Oprom This item can enable or disable PXE functions of integrated network card including Enabled default setting and Disabled two items Onboard NIC1 2 3 4 Control This item can enable or disable integrated network card including Enabled default setting and Disabled two items Onboard NIC1 2 3 4 ROM This item can enable or disable the ROM of integrated network card 1 2 3 4 including Enabled and Disabled two items If the network card is set to Disabled the ROM item of corresponding network card will autohide e Intel R VT D Configuration Intel R VT D Directed IO virtualization technology supports two options including Disabled default setting and Enabled e SATA Configuration This item can view the status of all the SATA devices connected to each SATA interface and set SATA controller mode and all SATA interfaces SATA Mode This item is used to set SATA controller modes including Disabled IDE Mode AHCI Mode and RAID Mode four items This server only integrates 2 SATA ports If you want to use serial devices as parallel IDE storage devices when onboard SATA controll
38. he chassis please check whether a redundant power supply is configured or not and whether there is an abnormal status light of the power supply module or a module without power cable when power alarm goes on the shield switch can be pressed to stop it e If the alarm sound is in the chassis the alarm may be from motherboard RAID card or hard disk back plane If it is also accompanied by no display on the monitor or power on faults there is high possibility of something wrong with motherboard You can try to pull or plug RAM or clear CMOS if the starting self check is normal and the alarm starts when the RAID card is under test and there is abnormal array information then it is likely that the RAID card has set off the alarm There may be array abnormality when the hard disk back plane alarms there is always abnormal status light of the hard disk on the front panel which can be used to help analysis 3 After having collected the basic information please feedback the detailed alarm information to Inspur technical support personnel in a timely manner We will make further analysis and judgment and help you solve the problem as soon as possible 5 3 Problems about Attached Ruijie Server Suite When using attached Reijie server suite to conduct server management and system auto installation configuration change factory settings change BIOS settings change and other reasons may cause abnormity during using process You can find and elimin
39. indows system and directly install browser plug in module Please install the browser plug in module on the user end before log into the remote desktop 2 Remote Login Method Input IP address of BMC in the IP address bar of client browser and then click Enter The management log in interface will appear just as shown in the following picture Username Password Forgot Password Login Please input default Username and Password Username admin Password admin Notice default Username and Password can conduct all module configurations and setting of permission So for security reasons it is recommended changing login password in time when you login 6 3 Function Menu Introduction The default display interface after logging in is as follows Dashboard FRU Information Server Health Configuration Remote Control Maintenance Dashboard Dashboard gives tha avarii information about the status of the device and ramat server Device Information Sensor Monitoring Firware Revision 1215 Firmware Buld Time Oct 18 2013 14 41 57 CST Stems Sensor Roading CPU_Status 10K Network information bd Stan WAC Address SC O2BROO7ACI WENORY_Suus 10K TaNsivuk ivir CHUP Powerl_Status NotAssiaie Prs aacrasa 1051 13 16 VO Network Mode DHCP Pvt Access Power2_Staua 10K tbtt Powerd Staus 10K 2 The following function menus can be found on the upper left corner of the interface Dashboard FRU Inform
40. ion Server Health Configuration Remote Control Maintenance HELP a Firmware Update A Preserve Configuration z Preserve Configuration This page allows the user to configure the preserve configuration items which will be used by the Reqs EmA Ennan SE rve the existing configuration without overwriting with default configuration Click here to go to Firmware Update or Restore Factory Defaults Number of Preserved Items 0 Preserve Configuration Item Preserve Status 1 SDR 2 FRU 3 SEL 4 IPMI 5 Network 6 NTP 7 SSH 8 KVM 9 Authentication Check All Uncheck All Save Reset G5 Chapter 6 Management Functions Introduction of Integrated management Card This function menu can realize remote update of BMC firmware and restart of IPMI card Firmware Update menu This menu can realize remote update of IPMI management card Firmware We recommend users not updating it by themselves If it really needs to be updated the update file must have been approved by us Preserve Configuration This menu can realize that the option values in the drop down box can be selected to remain unchanged before loading factory default values The selected option values will not be changed because of loading factory default values 3 Restore Factory Defaults This menu is used to load factory default values of IPMI management card Chapter 7 Server Installation Guide The Guide will help you to understand how to insta
41. ion interface including Use All Space Replace Existing Linux System s Shrink Current System Use Free Space Create Custom Layout This installation takes custom manual partition as an example so select Create Custom layout and click Next to continue the installation 12 The installation program enters the interface of selecting the hard disk to install In the Data Storage Devices to be mounted only list the system shows the detected storage device Please select hard disk to install the system according to the actual demand and add this hard disk to Install Target Devices Then select a hard disk as Boot Loader and click Next to continue the installation 13 When the installation program enters Please Select A Device partition creating interface if partition has been created on the hard disk it will be displayed and you can delete it if you do not need it Double click the Free partition or other existing partitions in the hard disk or click Create button at the lower right corner and the system will pops up Add Partition Create root partition and boot partition Select root partition in Mount point select the hard disk to install the system in Allowable Drives window input the Size MB of partition and click OK to finish the creating of root partition Create the boot partition in the same way boot 2 Create a swap partition Swap Select Swap in File system Type s
42. ith external RAID card or SAS sub card please refer to the electronic version of User Manual in the CD of external RAID card or SAS sub card to load the driver of the hard disk controller If it uses onboard SATA controller please make the driver of controller according to the attached driver CD For network card driver video driver and system patch program the guidance in the chapter can also be referred for setup This installation instruction states the manual installation of operating system Taking configuring 2108 SAS RAID as example if your server is configured with other external RAID card please load the HDD controller drive by referring to the user manual in the attached CD As for the network drive video driver and system patch program you can still refer to this chapter It is suggested that you confirm in advance that whether the purchased machine configuration supports the version of the operating system to be installed 4 1 Application Instructions for Inspur Driver U disk Under Windows system and Linux system Inspur driver U disk can be identified Chapter 4 Install Operating System o as two parts virtual floppy driver 3 5 floppy disk A and normal partition of U disk UDISK PRO When you install some operating systems manually you can use Inspur driver U disk to load the drive of hard disk controller at present the operating systems that use Inspur driver U disk to load the hard disk controller support Window
43. lation description attached with the cabinet products and get known about the special warning notices and installation process you must abide by the following preventive measures to guarantee the cabinet to be stable and safe Warning 10 Before installing equipment in the chassis please install front and side supporting feet on the independent chassis for cabinet connecting with other chassis it shall install the front supporting foot first If you fail to install correspondingly the supporting foot before installing equipment in the chassis it may cause the cabinet to turn over in some cases and thus may cause personal injury Therefore it is necessary to install supporting feet before installing equipment in the chassis After installing the equipment and other components in the chassis it can only pull out one component from the cabinet through its sliding component at one time Pulling out several components at the same time may lead the cabinet to turn over and cause serious personal injury Warning 11 Please do not move the chassis Considering the height and weight of the chassis at least two people are needed to complete its movement Warning 12 Declaration The product is Grade A product and in the living environment it may cause Chapter Safety Information o radio interference In such case it may need the user to take feasible measures for the interference Notes In order to help you use the equipment the followi
44. le Unit FRU This page gives detailed information for the various FRU devices presentin this system Basic Information FRU Device ID 0 v FRU Device Name BMC_FRU Server Information Chassis Type Rack Mount Chassis Product Name NF8420M3 Product Manufacturer Name Product Part Number Product Version Product Serial Number Product Asset Tag Board Manufacturer Manufacture Date Time lt Inspur 00001 00001 00001 Inspur0001 Inspur Sun Sep 30 09 27 00 2012 3 Server Health menu In this menu data information relating to server health including Sensor Readings Event Log and System and Audit Log can be checked Sensor Readings menu shows all Sensor values which are mainly Chapter 6 Management Functions Introduction of Integrated management Card temperature voltage and fan speed It can refresh and display according to category 2 Event Log menu displays sensor events BIOS events system management software events OEM events and remote console software event logs It can display according to category or display uniformly The user can view logs anytime and also can clear logs 3 System and Audit Log menu displays system log and check Log System log needs displaying according to category 4 Configuration menu Print Logout EET admin Administrator Refresh Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP Active Directory Field Replaceable Unit FRU
45. ll Inspur Yingxin NF8420M3 server in Inspur server cabinet or compatible standard industrial cabinet 7 1 Cabinet Preparation Angle rail adjustment in order to guarantee the server can be installed in the cabinet normally the clearance between the front and rear part of the angle rail should be adjusted to be at least larger than 750mm inner width between left angle rail and right angle rail should be larger than 480mm the space between cabinet door and front angle rail larger than 60mm Leveling cabinet the cabinet must be installed in a stable place Adjust the four support feet at the bottom of the cabinet to make the cabinet stable on the ground Meanwhile dismount the cabinet door for convenience of guide rail installation Cabinet grounding to avoid electric shock a grounding device must be installed in the cabinet If the server power line is installed in the power socket which constitutes a portion of the cabinet grounding should be properly provided for the cabinet If the server power line is inserted into the power socket in the wall the grounding device in the power socket just provides grounding for the server and then proper grounding protection for cabinet and other internal devices should be provided We recommend you to use the cabinet specially designed by Inspur for the server If so the internal of the cabinet should be already grounded Please don t change the ground joint in the cabinet unless it is of absolute nec
46. lly 2 In the Select OS column select Windows 2008 R2 3 In the Select Hardware column select Network card driver 4 Click Next to start the installation 5 Enter the interface of Intel Network Connections and double click Install Drivers and Software 6 Enter the interface of Welcome to the InstallShield Wizard for Intel R Network Connections and click Next to continue 7 Enter the interface of License Agreement select I accept the terms in the license agreement and then click Next to continue 8 Enter the interface of Setup Options and click Next to continue 9 Enter the interface of Ready to Install the Program and click Install to continue 10 The installation program starts to install when the installation is completed click Finish according to the prompt 18 Install Video driver After installing the network card drive please do not exit the installation interface of driver CD but continue the installation of video driver installation 1 In the Select OS column select Windows 2008 R2 2 In the Select Hardware column select Video driver 3 Click Next to start the installation Chapter 4 Install Operating System o 4 Enter the interface of Welcome to the InstallShield Wizard and click Next to continue 5 Enter the interface of License Agreement select I accept the terms in the license agree
47. me remote desktop display Refresh Video Refresh remote desktop display Compression Mode Compression mode setting Dct Quantization Table Remote desktop display quantization setting Host Video Output Open or close host video output display Full Screen Full screen display of remote desktop Exit Exit remote desktop Chapter 6 Management Functions Introduction of Integrated management Card B Remote desktop Keyboard menu Video Keyboari Mouse Options Media Keyboard Layo Video Recor Power Active User Help Hold Right Ctr Key NIE J C Hold Right Alt Key L Ed A C Hold Left Ctri Key Hold Left Alt Key Zoom Size 110 Left Windows Key gt Right Windows Key gt Ctri Alt Del Context Menu Hot Keys Menu Function Select this option equal to click the Ctrl key on the right side of the Hold Right Ctrl Key keyboard when operating Select this option equal to click the Alt key on the right side of the Hold Right Alt Key keyboard when operating Select this option equal to click the Ctrl key on the left side of the Hold Let C ELK EY keyboard when operating Select this option equal to click the Alt key on the left side of the Holl LER AE KEY keyboard when operating Selecting this option will appear Hold down and Press and Release Left Windows Key It stands for press down or release Windows key on the left side of th
48. ment and then click Next to continue 6 Enter the interface of Customer Information please input User Name and Organization and the click Next to continue 7 Enter the interface of Setup Type please select installation type in these two choices Complete and Custom Here select Custom click Next to continue 8 Enter the interface of Custom Setup and click Next to continue 9 Enter the interface of Ready to Install the Program and click Install to start the installation of video driver 10 The installation program starts to install when the installation is completed click Finish in the interface of InstallShield Wizard Completed and the system pops up a prompt that you need to restart the server so that the settings can take effect Take all the disks out of the drive and select Yes to restart the server Notes In the above Video driver installation some installation steps may be different because of the different Windows 2008 system versions to install so please follow the actual installation steps 4 3 Manually Install Red Hat Enterprise Linux 6 1 4 3 1 Preparation Prior to the Installation e Installation CD for Red Hat Enterprise Linux 6 1 1 piece of DVD 4 3 2 Installation Steps 1 Power up and start the system put the installation CD into the optical drive here taking using DVD installation disk as example enter BIOS to set and make the server boot
49. n board please power off the system and wait for 5 seconds and then dismount the components from the main board or disconnect the connection of peripheral equipment of the system 5 If there are modulator demodulator telecommunication or local area network options in the equipment please pay attention to the following matters In case of thunder and lightning weather please do not connect or use the modulator demodulator Otherwise it may be subject to lightning strike Never connect or use modulator demodulator in moist environment lt gt Chapter Safety Information Never insert the modulator demodulator or telephone cables to the socket of network interface controller NIC Before unpacking the product package contacting or installing internal components or contacting un insulated cables or jacks of the modulator demodulator please disconnect the modulator demodulator cables 6 In order to prevent the electrostatic discharge from damaging the electronic components in the equipment please pay attention to the following matters You shall conduct off the static electricity on the body before dismounting or contacting any electronic component in the equipment You can conduct off the static electricity on the body by contacting the metal earthing objects such as the unpainted metal surface on the chassis to prevent the static electricity on the body from conducting itself to the sensitive components For electr
50. n in picture 3 along the direction of arrow and then pull outward the inner rail completely with even strength Picture 3 Chapter 6 Management Functions Introduction of Integrated management Card 3 Fix the inner rail on the five screws on the chassis the fix position shown in picture 4 Picture 4 4 Make the smooth side of the inner rail confront the side of chassis get the holes on the inner rail and screws on chassis corresponding with each other well let the inner rail cling to the chassis closely then push the inner rail in the direction rear of the machine of red arrows shown in picture 5 and clamp tightly the inner rail with studs A Special notice when push the inner rail in the direction of red arrows if the inner rail can t be clamped into the stud slightly loose the five screws and then push the inner rail again After the inner rail is clamped tightly screw down Picture 5 5 Repeat step 1 4 install the other inner rail in the corresponding position at the other side of the cabinet 7 4 Install Slide Rail into Cabinet 1 Make sure the installation location of the slide rail on the cabinet firstly let the bearing studs of the front frame pass through the fixed hole of the cabinet s angle rail picture 6 Based on the depth of the cabinet properly adjust the back frame and fix the bearing studs of the back frame to the angle rail at the back of the cabinet Notice the front and back
51. nboard network card driver You can use the driver CD attached with the machine to update the network card manually 1 Insert Inspur driver CD into the optical drive click the Terminal menu in Applications System Tools input the following in the windows mount dev cdrom mnt cd mnt cd driver nic linux sv cp igb 4 3 0 tar gz tmp cd tmp tar zxvf igb 4 3 0 tar gz cd igb 4 3 0 sre make install cd umount mnt reboot Notes igb 4 3 0 tar gz is network card driver and its version will be updated When being installed the actual version name in the attached driver CD shall prevail 2 The system will automatically restart please take out the driver CD 3 Log in the system connect the network wires and configure the network Chapter 5 Common Problems and Trouble shooting This chapter focuses on the common problems and trouble shooting of the server If you are not sure about the cause of a failure and its removal method please contact our customer service center for solution Notes When replacing or installing hardware device for the server you should disconnect the power cable from the server completely It is recommended to use the anti static wrist strap and to earth connect the other end to provide electrostatic protection in dismounting the server 5 1 Restarting Server When a failure occurs please try to restart the machine according to the following methods first How to operate
52. ncrease with the increase of single memory capacity Memory advanced characteristics 4 channel access support memory mirroring and memory hot standby T O Interface USB interface 4 rear USB interfaces 2 front USB interfaces 3 internal USB interface Serial interface 1 rear serial interface 2 internal serial interface Network interface 4 RJ45 network interface 1 management interface Display interface 1 front VGA interface 1 rear VGA interface ID button and LED ID button and LED 1 ID button and LED in the front of the chassis 1 ID button and LED in the rear of the chassis Display controller Controller type Video memory Onboard AST2300 display controller 16MB Video memory HDD controller SAS controller Optional SAS RAID card or SAS card SATA controller Chapter 2 Product Introduction iE South bridge integrated SATA controller 2 SATA 3 0 interfaces on the mother board one SATA interface is used for connecting SATA optical drive Management card Management card chip Integrated A speed 2300 chip support IPM12 0 IK VM Management card interface IPMI management dedicated interface or multiplex onboard Intel I350 network card 3 is available Network card Network card controller Onboard 2 Intel I350 Gigabit network chips total 4 RJ45 interfaces Optional 10Gigabit Ethernet expansion card 2 RJ45 interfaces PCI expansion
53. nd User3 After set to admin user group user privilege and whether the user is available options can t be modified but only password can be set Chapter 3 System Setup o A Privilege set the privilege of user group including three options USER OPERATOR and ADMIN A User Status set whether the user is available including two options DISABLE default settings and ENABLE A User Name set the user name of user group The user name s length is at least 4 bytes but no more than 15 bytes A PASSWORD set the password of user name of user group The password s length is at least 4 bytes but no more than 15 bytes After this setting modification is completed it needs to restart the system Please wait for a while The operation can t take effect until BMC status light blinks and BMC works normally e System Health Information This menu enables user to check CPU temperature memory slot temperature PCH temperature fan speed voltage and other information System Temperature Information Entering this menu can view CPU temperature memory slot temperature system temperature and PCH temperature System Fan Speed Entering this menu can view 8 hot plug fans speed in front part of chassis There are altogether from left to right 8 fans in 4 groups displayed in BIOS corresponding to chassis front part In each group the fan which is close to the motherboard is the first fan System Voltage Information Ente
54. ng considerations can help avoid the occurrence of problems that may damage the components or cause data loss 1 In case of the following cases please unplug the power line plug of products from the power socket and contact the customer service department of Inspur The power cables extended cables or power plugs are damaged The products get wet by water The products have fallen off or been damaged Objects fall into the products When operating according to the operation instructions the products cannot function normally 2 If the system becomes damp please treat it according to the following steps Switch off the power supplies of the system and the equipment disconnect them with the power socket wait for 10 to 20 minutes and then open the cover of the host Move the equipment to the ventilation place to dry the system at least for 24 hours and make sure that the system is fully dried Close the cover of the host re connect the system to the power socket and then start the equipment In case of operation failure or abnormal situation please contact Inspur and get technical support 3 Pay attention to the position of the system cables and power cables wire them in places not to be stepped on or knocked down and ensure not to place other objectives on the cables 4 Before dismounting the cover of host or contacting the internal components you shall cool down the equipment first to avoid damaging the mai
55. ocess you can refer to the user manual 4 If all above operations failed to solve the problem it is suggested that you backup the file winnt minidump in disk C and call the service center for support from professional technical engineers who may ask you to provide minidump file for further analysis on the cause for blue screen and halt If there is no minidump folder in disk C please refer to the following steps right click on My Computer select Property advanced J startup and recovery then select settings change write debugging information in the next page to small RAM dump and restart the machine The system will produce minidump file automatically in the next blue screen 5 2 6 Machine Alarm If there s machine alarm in startup or utilization process please refer to the following measures 1 If this happens after you plugged in some external board you may need to pull off this device and to do another test If the alarm goes off it shows that your external board is incompatible with the machine It is suggested not to use it any more if the Chapter 5 Common Problems and Trouble shooting alarm is still on please go on referring to the following steps 2 Locate the alarm sound e When the alarm sound is from the front of the chassis usually we notice abnormal changes of the fault indicating light There is the possibility of abnormal fans or hard disk module e If the alarm sound is from the rear of t
56. oduct Introduction HDD failure alert indicator light When the hard disk fails it will turn red When the hard disk is under RAID card rebuilding it will turn purple When the hard disk is operating Locate it will turn blue Label mylar bar Pull mylar bar out and view product information from the label pasted on it Front VGA port Connecting VGA port display device USB port Connecting USB device USB port Connecting USB device 9 16 2 5 HDD bays HDDs supported by SAS module 2 and HDD8 HDD15 from left to right in turn Only the configuration with 4 CPUs supports more than 8 HDDs The configuration with SAS module 2 can t support standard SATA optical drive Optical drive optional SATA standard optical drive The configuration with SAS module 2 can t support standard SATA optical drive Right handle 2 3 Rear Panel View 7 8 Chassis handle on the right 9 5 11 R i 14 15 16 o Rear panel view Name Chapter 2 Product Introduction J Function and introduction PCIE 2 CPU 1 slot PCIE x16 slot CPU_1 supports PCIE_1 CPU1 hot plug slot PCIE x8 hot plug slot CPU_1 supports This slot supports hot plug function PCIE _0 CPU1 hot plug slot PCIE x8 hot plug slot CPU_1 supports This slot supports hot plug function PCIE_1 CPU1 hot plug slot on off switch and working status indicator light When PCIE _1 CPU1 hot plug slo
57. omatically reboot for several times 13 After the installation is completed the system would boot to the interface of The user s password must be changed before logging on the first time Take out the installation CD and then click OK to continue Notes As for the above Windows Server 2008 operating system installation steps because the used system CD version is different there may be some differences Please install it according to the actual display interface 14 Follow the prompt to set the Administrator password and then click the arrow button at the right of the password input box to continue If the password meets the requirements it will prompt Your password has been changed and then click OK to confirm that the password has been changed Windows Server 2008 has strict requirement for the password so it must contain letters numbers and special characters or the setting cannot be successful 15 After logging in the system select Do not show this window at logon at the bottom of the Initial Configuration Tasks interface and then click Close In the new interface of Server Manager select Do not show this console at logon and close the interface 16 Install Chipset patch 1 Insert Inspur driver CD into the optical drive click the blue dolphin icon under the installation or operation procedure item in the automatically playing interface popped out after the disk s running Enter W
58. ootable CD or system installation disk in optical drive of synchronous client set client CD drive as the first startup sequence in server BIOS settings Installation of ISO file is the same with remote CDROM installation which needs to set startup sequence in server BIOS F Remote desktop Keyboard Layout menu Menu Function Auto Detect Select this option and it will automatically detect the keyboard type SoftKeyboard Use soft keyboard There are keyboard types of many kinds of languages for choice G Remote desktop VideoRecord menu Select VideoRecord menu to set options related with video record Menu Function Start Record Select this option and start video record Stop Record Select this option and stop video record This option is used to set video record duration and storage directory Only after Settings the directory is set can the video record begin H Remote desktop Power menu Video Keyboarc Mouse Options Media Keyboard Layo Video Recor Poiia Active User Help T G oOee PJE d B Reset Server Immediate Shutdown Zoom Size 110 TiO Orderly Shutdown wer On Server Power Cycle Server Menu Function Reset Server Select this option to reset server Immediate Shutdown Select this option to shutdown server immediately Orderly Shutdown Select this option to shutdown server orderly Power On Server Select this option to power on server
59. ostatic sensitive components not ready to be installed for application please do not take them out from the antistatic package materials During the work please touch the earthing conductor or the unpainted metal surface on the cabinet regularly to conduct off the static electricity on the body that may damage the internal components 7 When dismounting the internal components with the approval of Inspur please pay attention to the following matters Switch off the system power supply and disconnect the cables including disconnecting any connection of the system When disconnecting the cables please grab the connector of cables and plug it out and never pull the cables Before dismounting the cover of cabinet or touching the internal components the products need to be cooled down Before dismounting and touching any electronic component in the equipment you shall conduct off the static electricity on the body by touching the metal earthing objectives During the dismounting process the operation shall not be too big so as to prevent damage to the components or scratching of the arms Carefully deal with the components and plug in cards and please never touch the components or connection points on the plug in cards When taking the plug in cards or components you should grab the edges of the plug in cards or components or their metal fixed supports lt gt Chapter Safety Information J 8 During the process o
60. p Zoom Size 110 Bandwidth rl ls Keyboard Mouse Encryption Zoom b Function Bandwidth Select this item to set displayed bandwidth Keyboard Mouse Encryption Encryption configuration for keyboard and mouse Zoom Select this item to magnify or minify the window of remote desktop Zoom In for magnifying and Zoom out for minifying E Remote desktop Media menu Click Media menu It will appear Virtual Media Wizard window In this window the user can load client side floppy disk image CD image and CD drive as is shown in figure below C Virtual Media s e e o al Floppy Key Media1 Floppy Image v Browse connect Hopes CDIDVD Media1 ISO Image Browse Connect CD DVD L DG Hard disk USB Key Media1 HD USB Image ee Connect Hard disk USB Key D PhysicalDrive0 Z C D E F Fixed Drive Status Target Drive Connected To Read Bytes Virtual Floppy 1 Not connected nla Virtual CD 1 Not connected nla Virtual HardDisk 1 Not connected nla ns Close Gd Chapter 6 Management Functions Introduction of Integrated management Card Select image type to load If to load floppy disk image please select Floppy Image And if to load CD image please select ISO Image then click Browse to select image location and click the corresponding Connect to complete loading image If it is b
61. pointer which means if you select this item and press Enter cascading menu that is submenu will be displayed on the screen Introduction of operational keys Button Description T up For selecting the upper menu or value down For selecting the next menu or value left For selecting the left menu or value right For selecting the right menu or value Esc For returning to the superior menu or the main menu For changing the item value For changing the current menu item into the previous item value The key only displays the item values relevant to the item itself rather than all the item values For changing the item value For changing the current menu item into the next item value The key only displays the item values relevant to the item itself rather than all the item values The help key for displaying the relevant introduction of current menu For recovering the previous default configuration For recovering the optimized performance configuration Chapter 3 System Setup EE F10 For saving CMOS settings and exiting Enter For executing current command or entering the submenu 1 Main menu In BIOS setup utility Main menu first displays In this menu BIOS version and memory capacity can be viewed System time date etc also can be set up in this menu To set system date and time use the arrow key to choose one of the options Press Enter to s
62. r once system prompts to insert system CD please don t intervene manually system installation will complete automatically otherwise it may cause system installation abnormity 5 3 4 Lose the Attached Reijie Server Suite CD or System Driver CD Please login Inspur official website and download the right version according to your machine model 1 Reijie server suite download link http www inspur com downloads channel_home Downloads_sv_1l asp 2 System drivers download link http www inspur com downloads channel_home Downloads_sv asp 5 4 Additional Notes 1 In order to guarantee the reliability of the system it is suggested that you use the component of the relevant Model tested and authenticated by us when expanding and equipping components 2 Please guarantee the fine electricity utilization environment of the server normal voltage input and earth connecting condition and temperature and humidity and so on within the normal range Chapter 5 Common Problems and Trouble shooting 3 For special needs when transferring the server pay attention to avoiding the vibration and carry out in power off condition 4 Solution for blurred screen when entering RAID card configuration interface In this server for some RAID card configuration such as 2008 RAID card 2108 RAID card 9261 RAID card 9211 SAS card configuration when entering RAID card configuration interface sometimes there is problem of blurred scr
63. r 4 Install Operating System aeeoe nw ae OT E Two methods to enter drive making software main interface as follows e Inthe text box below Please input navigation No input navigation No check navigation No on CD cover to log in the drive making software main interface Click Exit to exit the log in e In the drop down menu below Please select the machine type select this server s type As for specific type please refer to host nameplate label 2 After inputting the navigation No or selecting machine type to log in enter the main interface of driver making software The main interface is shown in the following picture rem RVERT J EXPECT Common Tools Introduction Chapter 4 Install Operating System 3 After you select the corresponding operating system and the controller driver to be made according to the actual need click Next button and make corresponding driver Different operating systems correspond to different making interfaces and methods of the driver e Driver making of Windows system When the driver of Windows operating system is made copy the driver directly into the virtual floppy drive A of Inspur driver U disk Select the Windows version to be installed and driver to be made and then click Next The system will display a prompt as shown in the following picture Please confirm that Inspur driver U disk is well connected Format the virtual floppy drive A of In
64. rd BIOS of this server at any time except for the parameters which we promote that you can alter 2 If there are any hardware problems when you use this server or you wish to upgrade the hardware please feed back the detailed hardware configuration of your server to our Customer Service Don t disassemble the server case or any hardware components in the case by yourself 3 In this server the MEMORY CPU CPU Fan Fan and so on are all in given standard Please don t use them together with the corresponding components of any other machines 4 When you have any software problems during the application of this server we hope that you firstly contact the corresponding software supplier and then he will contact us in favor of communication so as to solve your problem together especially for the software problems about the installation and operation of the database network management software or other networking products 5 The figures in the pressworks attached to the server are just for your reference The server that you purchase prevails 6 Please read carefully our user manual before you install this server If you have any questions about the usage please contact our Customer Service 7 We must call your attention that in the application process you should pay attention to doing necessary backup of your file 8 This is a Grade A product and this product may cause radio jamming In this case users need to adopt feasible mea
65. ring this menu can view system power module information as well as whether BIOS normally gets voltage information e View System Information This menu enables user to check detailed information of the system such as system manufacturer product name SDR version BMC version and other information 5 Boot menu Boot menu is mainly used to the configuration of system boot process and system boot devices priority e Boot Devices Seeking This item is used to open or close the function of retrying to seek boot devices during system starting procedure including Enabled default setting and Disabled Chapter 3 System Setup ES two items e Quiet Boot This menu is used to set the display status in system boot process If the system is set to Disabled it shows self check process and information If the system is set to Enabled default setting it shows manufacturer LOGO e Boot Option 1 2 3 Select certain boot order device item and press Enter button The system will display optional boot device table Then select a device through arrow key in the table and press Enter to finish the setting of the boot order item e Hard Drive BBS Priorities Press Enter to enter the sub items of this menu and set up the boot order of the HDDs 6 Security menu e Administrator Password This menu is used to set up system administrator password After the setup of the administrator password you must input the password when entering the BI
66. s XP or above versions Red Hat Linux 4 5 or above versions and Suse Linux 9 0 SP2 or above versions Warning During the installation of the operating system by using Inspur driver it may detect Inspur driver U disk on the disk partition interface At this moment the user must distinguish U disk from hard disk and never delete or format U disk During the installation of the operating system if it needs to boot the system from hard disk after reboot it must enter the server BIOS for setting to ensure the starting sequence of hard disk is prior to the starting sequence of U disk and the system can boot from the disk If the starting sequence of U disk is prior to the starting sequence of hard disk the system will fail to boot from hard disk The following introduces the making method for the driver of onboard hard disk controller when using Inspur driver U disk to install the operating system For driver making of external RAID card or SAS card please refer to the corresponding contents in the driver CD of external board card Make Driver 1 Prepare a set of computer installed with Windows system and connect the Inspur driver U disk to the USB interface of the computer as is shown in the picture below Inspur driver U disk will be identified as two parts virtual floppy driver 3 2 Floppy A and normal partition of U disk Removable Disk E Among of them the disk character E in Removable Disk E will be different according to
67. se connect Inspur driver U disk when starting the server e Please check whether the driver having been made is correct or not the drive for external RAID card should be made directly from the attached RAID card driver CD and whether there is fault in the floppy disk or Inspur driver U disk Chapter 5 Common Problems and Trouble shooting 5 2 4 Keyboard and Mouse Do Not Work 1 Check whether the cable joint of the mouse and keyboard is plugged and connected correctly Make sure the joint pin has no curve 2 Check whether the mouse setting in the control panel of the operating system is correct or not 3 Clean the scrolling and drive shaft of the mouse 4 It is suggested that you use the keyboard and mouse tested for compatibility by Inspur group or replace with other keyboard and mouse for testing 5 2 5 System Blue Screen Halt or Restart For blue screen restart or halt of the machine in the utilization of the system you may refer to the following measures 1 If other external non Inspur components or some application program software are installed before the fault it is suggested removing it and going on to test your server 2 Use the latest antivirus software for antivirus test 3 It is suggested that you record the displayed information code for blue screen such as stop c000000218 stop 0x0000007b This kind of information reveals problems in the system It is suggested that you reinstall it For the installation pr
68. smount and replace the internal components Warning 2 Please connect the equipment to appropriate power supply and the power should be supplied by external power supply which is indicated on the rated input label To prevent your equipment from damages caused by momentary spike or plunge of the voltage please use relevant voltage stabilizing equipment or uninterruptible power supply equipment Warning 3 If extended cables are needed please use the three core cables matched with correct earthed plug and check the ratings of the extended cables to make sure that the sum of rated current of all products inserted into the extended cables do not exceed 80 of the limits of the rated currents of the extended cables Warning 4 Please be sure to use the supplied power supply component such as power lines power socket if supplied with the equipment etc For the safety of equipment and the user do not replace randomly power cables or plugs Warning 5 To prevent electric shock dangers caused by leakage in the system please make sure that the power cables of the system and peripheral equipment are correctly connected to the earthed power socket Please connect the three core power line plug to the three core AC power socket that is well earthed and easy to access be sure to use the earthing pin of power lines and do not use the patch plug or the earthing pin unplugged with cables In case of the earthing conductors not installed and it is uncertain
69. snesieseasentectusdaavdesdunevialanstdeara died ninle duende dues 44 5 5 Technical Support Informatio sssrin ie nr EE 45 Chapter 6 Management Functions Introduction Of Integrated Management Card E E E E E E T 47 6 1 Manasement Chip BMC IPs ars senanesmnennn n R neeauiac 47 A REMOTE LO CIM EE EE E E A A OE OA A OO A EET 47 6 3 Function Menu troduction seeiis nee anr Raa R r REE A 48 Chapter 7 Server Installation Guide 0 00eeeeseeeeeeeeeeneersrssererssensenersrsnensresenesee 57 Ti Cabinet Preparations nase nnnan anann ERE E E R 57 7 2 Components Needed in Server Installation cccceccscesseesseeseteeeeteeeeeeeaes 58 T3 Tnstallatiom of Inner Rail ij c sseisseeiseeiocench ineuanvedeevievancsqnedandectsabeeanssanvdeavaaysannee 58 7 4 Install Slide Rail into Cabinet sassis e p 59 7 5 Install the Server to Cabinet ecesccesceeseceseceeeeneeeneeeeeeeeeneeeeeeneeeeeneeenees 61 Chapter 1 Safety Information A Warning The following warnings show that there are potential dangers that may cause property loss personal injury or death Warning 1 The power supply equipment in the system may generate high voltage and dangerous electrical energy and thus cause personal injury Please do not dismount the cover of the host or to dismount and replace any component in the system by yourself unless otherwise informed by Inspur only maintenance technicians trained by Inspur have the right to disassemble the cover of the host di
70. spur driver U disk and then click OK to start the driver making Make Driver Inspur driver U disk a xj Please insert Inspur driver U disk or Floppy Disk and quick format lt a gt disk firstly After the driver making is completed the system will pop up the window prompting Driver has been completed Click OK to complete the making of driver e Notices for using Inspur driver U disk to load driver under windows system During the installation of Windows operating system if the driver of hard disk controller is loaded by using Inspur driver U disk entering the interface of disk partition Inspur driver U disk will occupy a disk letter If the disk is not partitioned U disk will occupy disk C If the disk has other partitions U disk will occupy other disk letter please distinguish according to the actual hard disk partition If there are other partitions on the disk at this moment it needs to delete all of them and then create new partitions on the hard disk The U disk will not occupy disk letter any more Chapter 4 Install Operating System zm If the disk is not partitioned it needs to create one disk partition on the unallocated space and then delete this newly created disk partition And at this time the U disk will not occupy any disk letter any more Then create disk partition based on actual need and complete the installation of operating system according to the instructions Notes Be sure to disting
71. ssing If you have a driver floppy disk CD DVD or USB flash driver please insert it now Notes If the Windows installation media is in the CD DVD drive you can safely remove it for this step If USB floppy drive is used please put the ready made driver floppy disk into GD floppy drive Chapter 4 Install Operating System If Inspur driver U disk or general U disk is used please confirm that there is no problem for U disk s connection And then click Browse button select the path of the driver and click OK The system will automatically search the driver 6 In Select the driver to be installed interface select the driver to be installed and then click Next to start loading driver 7 In Type your product key for activation interface input your product key 25 character and then click Next to continue 8 In Select the edition of Windows that you purchased interface select the operating system version to be installed then select I have selected the edition of Windows that I purchased and click Next to continue 9 The Microsoft software license clauses will be shown in the interface of Please read the license terms Select I accept the license terms and after reading click Next to continue 10 In the interface of Which type of installation do you want select the installation type and here the default set by us is the first installation Select Custom model to
72. st be shut down and power supply cut off Short cut pin2 3 for 5 seconds And then reuse jumper cap to short cut Pin and Pin2 default state and restore to the original state 2 After the jumper operation please install the upper panel of the chassis QD Chapter 4 Install Operating System This chapter primarily focuses on the method for manually installing the prevailing operating system to the server Ruijie Server Kit supports the intelligent and automatic installation of mainstream Windows operating system and Linux operating system As for the actual operating system supported the optional operating system versions in the drop down menu of Select the Operating System in the software prevail What s more some configuration of the server may not support the automatic installation of these operating systems such as onboard SATA HostRAID configuration you need to install other version of the operating system manually according to the actual demands During manual setup of the operating system some operating system may need the floppy drive or Inspur driver U disk to load the driver of hard disk controller Refer to the readme pdf file under the root directory in Inspur driver CD for the making method of the driver floppy disk If the configuration you purchased is configured with Inspur driver U disk you may refer to relevant contents of this chapter for the making method of Inspur driver U disk If your server is configured w
73. sures to the interference 9 The copyright of the marks and names of all the software and hardware products involved in this manual is reserved by the relevant companies 10 In the statements above us indicates Inspur Inspur holds the right of final explanation about the above statements Regarding the Manual e Chapter One Safety Information In this chapter safety information regarding server usage is introduced e Chapter Two Product Introduction In this chapter the technical characteristics appearance features I O interface technical specification of this server are introduced e Chapter Three System Setup In this chapter the setup of the main board BIOS of this server and the usage of some common jumpers is introduced e Chapter Four Install Operating System In this chapter how to install the main operating system to this server is introduced e Chapter Five Common Problems and Trouble shooting In this chapter solutions to some common problems are introduced e Chapter Six Management Functions Introduction of Integrated management card In this chapter the usage of integrated management card of this server is introduced e Chapter Seven Sever Installation Guide In this chapter how to install server to the cabinet by rail is introduced We suggest you read this manual carefully before you use this server for fear of the unnecessary faults in your operation Address No 1036 Langchao Road Jinan City China Inspur
74. t is configured with expansion card and if the indicator light is normally on the expansion card in this slot works normally If it needs to online replace the expansion card in this slot press the switch of this hot plug slot And then online replace the expansion card in this slot after the indicator light is off After the replacement is completed again press the switch of the hot plug slot After the indicator light is normally on the expansion card works normally PCIE_0 CPU1 hot plug slot on off switch and working status indicator light When PCIE _0 CPU1 hot plug slot is configured with expansion card and if the indicator light is normally on the expansion card in this slot works normally If it needs to online replace the expansion card in this slot press the switch of this hot plug slot And then online replace the expansion card in this slot after the indicator light is off After the replacement is completed again press the switch of the hot plug slot After the indicator light is normally on the expansion card works normally 10Gigabit network port B optional This port is available only when PCIE 3 CPU1 slot is configured with 10Gigabit Ethernet expansion card 10Gigabit network port A optional This port is available only when PCIE 3 CPU1 slot is configured with 10Gigabit Ethernet expansion card VGA port Connecting VGA port display device Serial port Connecting serial port device 1
75. the actual partitions of your computer Chapter 4 Install Operating System Pryce eee RAE f file gdt Yew Favortes Took tep r Ous OT Psewh Oroes gt X19 address 3 My Conanter ENE Nave te Total Sus Free Space Comments Hard Disk Drives Local Disk C Local Disk 19 568 15 78 Devices with Removable Storage Pis Foppy A 314 Inch Floppy Disk lt Wh 20080818 H CD Drive Removable Disk E Removable Disk lt Notes Before connecting the Inspur driver U disk to the computer if your computer is configured with standard floppy please enter BIOS and close this standard floppy if your computer is connected with USB floppy please first disconnect USB floppy It must guarantee that when the Inspur driver U disk is connected to your computer the disk character of virtual floppy driver under Windows system shall be identified to be A and only by this can the subsequent normal driver making be guaranteed 2 Put the driver CD Inspur driver CD and RAID card driver CD into optical drive and the driver making software will operate automatically If the system forbids the automatic operation of CD please enter CD directory and operate dolphin bat Inspur driver CD in CD or setup exe RAID card driver CD in CD directory 3 Methods for making drivers by using Inspur driver CD 1 After operating dolphin bat documents the system will enter the interface of Welcome to Inspur driver CD Chapte
76. uction 4 The contents of the BIOS may differ due to the different configurations of products no detailed introduction will be provided here 3 1 1 How to Enter the BIOS Setup Power up and start the server When the prompt Press DEL to SETUP or TAB to POST displays on screen below press DEL and wait for a while And then the system enters BIOS setup If the system does not enter BIOS setup after previous steps please press Ctrl Alt Del at the same time to reset the system and repeat operations above If the lt gt Chapter 3 System Setup prompt displays to press DEL again please press it quickly 3 1 2 BIOS System Menu Introduction Next the Menu Name following main function menus of BIOS are introduced Menu Function Main Configuring the basic system settings such as system time system date displaying BIOS information system memory capacity etc Advanced Configuring CPU integrated SATA controller and other advanced characteristics Chipset Configuring memory mode CPU characteristics etc Server Mgmt Configuring server management functions Boot Configuring boot priority of system devices Security Configuring the system super user and password Save amp Exit Saving or exiting BIOS setup etc Some items in BIOS cannot be configured for example information of system detecting and configuration For some items there is a right
77. ugh the third hole picture 9 in the front of slide rail corresponding to angle rail Chapter 6 Management Functions Introduction of Integrated management Card NSDur ine Picture 9
78. uish U disk from hard disk and never delete or format U disk 4 2 Manually Install Windows Server 2008 R2 4 2 1 Preparation Prior to the Installation e Windows Server 2008 Installation disk DVD e Inspur driver CD e HDD controller driver floppy disk the configuration with external LSI 2108 RAID card does not need driver for Windows Server 2008 R2 installation e As for the above mentioned drivers if USB floppy drive is used please make the driver into floppy disk if Inspur driver U disk is used please make the driver into Inspur driver U disk if general driver U disk is used input the disk letter occupied by general U disk and the directory for saving the driver to make the driver into general U disk 4 2 2 Installation Steps 1 Connect well USB floppy drive or Inspur driver U disk or general U disk power up to start the server put the installation CD of Windows Server 2008 into optical drive and then enter BIOS to configure so that the server can boot from CD 2 Press any key when the system presents Press any key to boot from CD or DVD and the system will start Windows installation program from CD 3 According to actual needs set Language to install Time and currency format Keyboard or input method And then click Next to continue 4 In the interface of installation confirmation click Install now to continue 5 The system pops up Load Driver window prompting A Required CD DVD drive device driver is mi
79. whether there are appropriate earthing protections please do not operate or use the equipment Contact and consult with the electrician please Warning 6 To avoid short circuit of internal components and fire or electric CD Chapter Safety Information shock hazards please do not fill any object into the open pores of the system Warning 7 Please place the system far away from the cooling plate and at the place with heat sources and be sure not to block the air vents Warning 8 Be sure not to scatter food or liquid in the system or on other components and do not use the product in humid and dusty environment Warning 9 The replacement of batteries with those of another model may cause explosion When replacement of batteries is required please consult first the manufacturer and choose batteries of the same or a similar model recommended by the manufacturer Do not dismount extrude and pink the batteries or make the external connection point short circuit and do not expose them in the environment over 60 C Never throw them into fire or water Please do not try to open or repair the batteries and be sure to reasonably deal with the flat batteries and do not put the flat batteries the circuit boards that may include the batteries and other components with other wastes For relevant battery recovery please contact the local waste recovery and treatment mechanism If what you bought is the chassis besides carefully read the instal