Home
ConnexLink User`s Manual
Contents
1. Multiple Networks Of ConnexLink Units Chient Client Chent Client Example Channel Number 13 Example Channel Number 25 System ID 001002003004005006007008 System ID 012023034045056067078089 1 1 ConnexLink Definitions k Pwr Red LED indicates power is connected to the unit Link Green LED indicates the Client unit s and Server unit are in range of one another Rx Red LED indicates when a ConnexLink unit is receiving data Tx Green LED indicates when a ConnexLink unit is sending data a gt oO N Reset Button Push button switch located closest to the power connector and serial cable on the bottom of the unit See Figure 2 below 6 Program Button Push button switch located next to the Reset Button on the bottom of the unit See Figure 2 below Figure 2 ConnexLink Bottom View P O O TEA AF O 3 9 9 13514 ra Tak r Sa a 6 3 2002 5 ConnexLink User s Manual 1 2 ConnexLink Configuration Utility Software The software CD included with your ConnexLink units provides a utility for changing the settings on each unit The software is compatible with Microsoft Windows 95 98 2000 Me and NT 1 21 Installation Follow the procedure below to install the ConnexLink Configuration Utility software Insert the CD into the desired CD ROM drive on your computer Click on the Windows Start menu and select Run Select Browse and then select th
2. compliance operations at closer than this distance is not recommended The preceding statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF Exposure compliance 6 3 2002 Table of Contents 1 OUT Wi ConnexLink 2 ConnexLink Configuration Utility Software 1 2 1 A ende 1 2 2 Software Definitions 1 2 3 Programming es Aaaa E 1 3 AS A 1 4 Figures Figure 1 Multiple Networks Of ConnexLink Figure 2 ConnexLink Bottom View uuunnsssensnnnssennnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnenn nenn 6 3 2002 ConnexLink User s Manual 1 Overview The ConnexLink products provide a wireless RS232 connection between different devices Each ConnexLink unit can be programmed as a Server or a Client allowing for the creation of a two device or multiple device wireless network In addition multiple networks can be created by programming each network of ConnexLink units with unique Channel Number and System ID combinations See Figure 1 below To create a wireless network simply program one of the units as a Server and the other units as Clients Figure 1
3. ConnexLink unit to a serial communications port on your computer Connect the power supply to the ConnexLink unit Make sure the Pwr LED is on Start the ConnexLink Configuration Utility Select Settings to display the Computer Settings window a Select the COM Port that is connected to the ConnexLink unit b Select the baud rate of the ConnexLink unit All ConnexLink units are shipped with a default baud rate of 57600 If the baud rate of the ConnexLink unit is changed as described below in Section 1 2 3 1 Changing ConnexLink Settings then this setting must be set to the same baud rate to allow proper programming of the units Select system configuration for the ConnexLink network Point to Point one Server and one Client or Point to Multipoint one Server and multiple Clients d Select OK Press and hold the Program Button located on the bottom the unit While holding the Program Button press the Reset Button also located on the bottom of the unit Release the Reset Button first followed by releasing the Program Button The ConnexLink unit is now in program mode See Figure 2 ConnexLink Bottom View for location of buttons 1 2 3 1 Changing ConnexLink Settings After the ConnexLink unit has been set up in Program Mode any settings can be changed and saved in the unit This is accomplished with the following procedure Select Read Radio to display the current settings of the ConnexLink unit Change desired settings A
4. DAEROCOMM ConnexLink User s Manual Version 1 0 Document Information Copyright Copyright 2001 Inc All rights reserved Inf ti The information contained in this manual and the accompanying nrormation software programs are copyrighted and all rights are reserved by AEROCOMM Inc AEROCOMM Inc reserves the right to make periodic modifications of this product without obligation to notify any person or entity of such revision Copying duplicating selling or otherwise distributing any part of this product without the prior consent of an authorized representative of AEROComM Inc is prohibited All brands and product names in this publication are registered trademarks or trademarks of their respective holders This material is preliminary Information furnished by AEROCOMM in this specification is believed to be accurate Devices sold by AEROCOMM are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only AEROCOMM makes no warranty express statutory and implied or by description regarding the information set forth herein AEROCOMM reserves the right to change specifications at any time and without notice AEROCOMM s products are intended for use in normal commercial applications Applications requiring extended temperature range or unusual environmental requirements such as military medical life support or life sustaining equipment are specifically not recommende
5. d without additional testing for such application Limited Warranty For a period of one 1 year from the date of purchase AEROCOMM warrants the transceiver against defects in materials and workmanship AEROCOMM will not honor this warranty and this warranty will be automatically void if there has been any 1 Tampering signs of tampering or opening the tranceiver s case 2 Use of AC power adapters and cables other than those originally supplied with the transceivers 3 Repair or attempt to repair by anyone other than an AEROCOMM authorized technician This warranty does not cover and AEROCOMM will not be liable for any damage or failure caused by misuse abuse acts of God accidents electrical irregularity or other causes beyond AEROCOMM s control or claim by other than the original purchaser 6 3 2002 2 FCC Information FCC Notice A WARNING This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation RF Exposure For 200mW units only Part Numbers CL200 amp CL200A A WARNING To satisfy FCC RF exposure requirements for mobile and base station transmitting devices a separation distance of 32cm or more should be maintained between the antenna of this device and persons during operation To ensure
6. e appropriate CD ROM drive letter Select the file named Setup exe and then select Open Select OK to begin the installation When prompted accept the default directory or change to the desired directory where the program files will be installed 7 Select Installation to begin copying files 8 When finished a window will be displayed indicating a successful installation Select OK DARAN 1 2 2 Software Definitions 1 2 2 1 ConnexLink Settings Window 1 Client Server Designates ConnexLink type In each network there must be only one Server All other ConnexLink units must be programmed as Clients The number of Clients in the network is not limited however if performance diminishes consider additional RF Networks 2 Baud Rate This defines the Serial baud rate between the ConnexLink unit and the host device such as a PC The RF transmission rate is fixed 3 Maximum Transmit Attempts For Point to Point networks only This value represents the maximum number of times a data packet can be sent by the ConnexLink units The default value is 10 attempts If communication is lost and the Client s Link LED is on try increasing this value in small increments until communication is reestablished The valid range of values for this field is 1 to 255 4 Broadcast Attempts For Point to Multipoint networks only This value represents the number of times a data packet will be sent by the Server ConnexLink unit The default value is 4 a
7. ents until communication is established If these troubleshooting tips do not resolve the problem please call our toll free technical support number at 800 492 2320 extension 201 Technical support hours are Monday through Friday 8 00 am to 5 00 pm Central Standard Time 6 3 2002
8. fter all changes have been made select Write Radio to save the changes a message window will be displayed Press and hold the Program Button b While holding the Program Button select OK Wait for a message window to be displayed confirming the saved changes d Release the Program Button and select OK Press the Reset Button located on the bottom of the unit after all changes have been saved This will set the ConnexLink unit to its normal mode of operation 6 3 2002 ConnexLink User s Manual 13 Troubleshooting Problem Read Radio displays error message Radio not responding Write Radio displays error message Radio not responding Client s Link LED does not come on Link LED is on but data does not get transmitted or received Make sure the ConnexLink unit is in Program Mode See Section 1 2 3 Programming Make sure the ConnexLink unit is in Program Mode and the Program button is depressed until message is displayed to release the button See Section 1 2 3 Programming Make sure Server ConnexLink unit is connected to power Press the Reset button or disconnect and reconnect power Make sure the ConnexLink unit s is connected to the correct COM Port Make sure the baud rate of the ConnexLink unit s is equal to the baud rate of the device it is connected to Try increasing the Maximum Transmit Attempts for Clients and or Broadcast Attempts for Servers values in small increm
9. ttempts If communication is lost and the Clients Link LED is on try increasing this value in small increments until communication is reestablished The valid range of values for this field is 1 to 255 5 Channel Number A number that designates an independent network of ConnexLink units Up to 77 independent networks can created The valid range of values for this field is O to 76 6 System Identification A sequence of eight numbers that provide added security to each independent network of ConnexLink units The valid range of values for each of the eight numbers is 0 10 255 Important Note For a network of ConnexLink units to communicate with each other all ConnexLink units must have identical Channel Numbers and System IDs If additional networks are created each network must use different Channel Numbers and System IDs so that existing networks are not interfered with 6 3 2002 6 ConnexLink User s Manual 1 2 2 2 Computer Settings Window 1 1 2 3 Port Serial communications port connected to the ConnexLink unit Baud Rate Serial baud rate of the PC COM Port System Config Type of ConnexLink network to be configured Valid choices are Point to Point one Server and one Client or Point to Multipoint one Server and multiple Clients Programming Each ConnexLink unit must be set up in Program Mode before any settings can be changed This is accomplished with the following procedure 1 N Connect a
Download Pdf Manuals
Related Search
Related Contents
Samsung 720NA User Manual Technical Zoom Manuale d`uso e manutenzione SIR Rev.03 2013 Copyright © All rights reserved.
Failed to retrieve file