Home
SLP PIPE LAYING LASER USER`S MANUAL
Contents
1. Follow the advise issued by your national occupational safety agency WARNING Do not stare directly into the laser beam The external power cable can be connected to a 12 V battery for long uninterrupted operation Please note that this does not charge the AC 1 5 TECHNICAL DATA Laser SOUFCE ceeeeeeeeeeeeeeeeteteteeeeees Laser diode Wavelength 635 nm Laser safety class sccesceeeeeeeeees Class 3R max output 3 5 mW Beam diameter at 100 m 0005 14mm RANJE ooieoe 200m Power source Built in Ni Mh 8Ah Battery life full charge 01 0 12 100h normal 20h worst conditions External power cable 0 000 Built in polarity protection use 12V battery Operating temperature 20 C to 50 C Sealing cccccceeee Waterproof sealed purged with nitrogen LON GWM acs sti ces ceearencnrecedethocn in ensanctes 295mm DIGMOHEN coionnan 142mm Weight Levelling range in beam direction 10 Cross axis tilt range ccceeeeeeree 3 Grade range ceeeeeeeeeeeeeees 10 to 40 Grade increment 0 002 per step Side alignment range 00 20m at 100m Accuracy at grade 0 ccceees 5mm at 100m Automatic tilt compensation Compensated to full grade accuracy within cross axis tilt range Vertical beam travel 0 eeeee Alignment error lt 5
2. figure 10 starts blinking on the display As long as it blinks you can select the next figure using the side alignment buttons 3 and change its value with the and buttons 7 After a few seconds of inactivity the blinking stops Side alignment Press the side alignment buttons 3 on the laser key pad to move the beam sideways By holding the button down the beam accelerates One press will move the beam 2 mm sideways on 100 m Press both side alignment buttons simultaneously and the laser automatically centres the side alignment Backlight By pressing the backlight button 9 on the laser key pad the light behind the display is lit for better visibility It stays on for a few seconds The backlight is also lit when any other button is pressed Self levelling When the laser has not completed levelling the laser beam has not reached its correct height This is indicated by a blinking laser beam and laser symbol on the display If the working position of the laser is tilted nose up or nose down more than app 10 degrees it will not be able to self level Correct this by repositioning the laser Cross axis tilt The cross axis indicator 6 on the display shows if the laser is tilted more than 3 degrees in the cross axis roll by blinking and showing with the level vial bubble in which direction it is tilted Readjust the position of the laser to correct this The remote control The remote control enable
3. 0mm at 100m over 10 grade travel within cross axis tilt range Remote control cceeeeeeeeeeeeees Waterproof metal housing Remote control functionality Side alignment display backlight stand by on off grade set Remote control range 100m normal conditions 40 m in bad conditions Remote control power source Built in battery 2x3 6V Lithium R life 1 year normal usage Stand by function ccccccceseeeceeeeeees From remote control power usage 50 of operating FIGURE 2 REMOTE CONTROL 1 Function indicator 2 Backlight button 3 Side alignment buttons 4 Stand by button 5 Grade setting buttons 2 OPERATION Turning the laser on Place the SLP in working position Turn the laser on with the on off button 1 on the laser key pad Code lock If the code lock function is enabled by your dealer you will be prompted to dial in your user code when the instrument is turned on Dial it in by selecting the digit with the side arrow buttons and setting the digit with the buttons If you lose your user code you have ten tries then the laser is permanently locked and must be returned to your AMA dealer for unlocking Grade setting Set the desired grade with the grade setting buttons 7 on the laser key pad Press once and the grade changes by 0 002 0 02 o By pressing the key a longer while the grade accelerates If you press or once the lowest
4. 6 WARRANTY Products sold by AMA Laser AB are warranted by the company in the following manner to the following extent Subject to the succeeding provision hereof AMA Laser warrants products sold by AMA twenty four 24 months after date for delivery from AMA Laser AB The manufacturer s liability under this warranty is limited to repairing or replacing any product returned to the factory or authorised service centre and judged upon inspection to have been defective in material or workmanship This warranty covers the cost of labour as well as parts but does not cover the cost of transportation to and from the factory or authorised service centre The forgoing states the entire liability of AMA Laser AB to the owner of a registered AMA product AMA Laser AB shall not be held responsible for any consequential damages of any kind The forgoing is in lieu of all other warranties expressed or implied In case of malfunction contact your AMA Dealer for shipping instructions Important Your warranty card must be completed and mailed to manufacturer upon purchase to validate warranty AMA Laser AB Fr sarv gen 7 SE 142 50 SKOGAS SWEDEN Tel 46 0 8 981098 Fax 46 0 8981099 E mail info amalaser com LASER RADIATION AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT MA LASER SLP PIPE LAYING LASER USER S MANUAL CONTENTS 1 What s what 2 Operation 3 Calibration 4 Battery power 5 Technical data 6 Warranty
5. er a few seconds of inactivity the quick blinking stops and you can no longer change the grade from the remote The SLP now works with a temporary grade but still remembers the old grade that you set on the laser keypad Both grades will alternatively show on the display As an additional warning the laser beam will flash once every 10 seconds To go back to the stored grade press Stand by 2 twice to put the laser to sleep and back to life The laser has now forgotten the temporary grade setting from the Remote Control To store this temporary grade as the new working grade hold down the backlight button on the laser keypad for 10 seconds The temporary grade has now become the stored grade The display shows dry briefly to confirm 3 CALIBRATION Calibration checks should be done regularly to ensure good results Checks can be done in the field using a measuring distance of approx 50 meters Mark two points at the distance From behind one of the points aim a level beam from the SLP over the two points and measure the distance between each point and the beam Move the laser behind the second point and repeat the procedure aiming the beam now in the opposite direction If the beam is indeed level the difference between the first and second measurements should be the same If this is not the case the SLP is in need of calibration by your AMA dealer 4 BATTERY POWER The SLP is powered by an in built battery pack The batter
6. gnment position indicator Close range remote control detector Cross axis angle indicator Grade setting buttons Warning indicator for laser radiation Display backlight button 10 Grade setting figures 11 Percent Promille indicator OONOaARWN
7. s you to work the laser from a distance The SLP has two main detectors pointing in the direction of the laser beam with high amplification for long working range and a single detector 5 pointing upwards from the laser keypad for limited working range Remote backlight Press the backlight button 2 for remote backlight This enables better visibility when the laser is in a manhole Stand by Press the stand by button 4 on the remote to bring the laser to stand by In stand by mode the laser draws approx 50 of the normal operating current and saves battery life It also enables you to avoid irritation when the laser beam is not needed Press Stand by again to bring the laser back to life Remote side alignment You can also use the remote control for side alignment The arrows 3 are set to work in the right direction if you stand where the beam hits and point the remote control towards the laser Flashing By pressing the remote control backlight button 2 for 5 seconds the beam starts flashing for better visibility The flashing is interrupted if the laser is outside of its cross axis levelling range Grade setting from the remote control To avoid mistakes do not use this feature before you understand how it works and have practised To enable remote grade set hold down the or button 5 on the remote for 5 seconds The laser beam now starts flashing quickly and starts moving in the desired direction at an accelerating pace Aft
8. y life during operation is more than 100 hours under normal conditions with a fresh battery pack With a worn battery pack and in cold temperatures the laser can still operate some 20 hours Frequent use of the Stand by function prolongs the working life The battery indicator 2 on the display gives an indication of remaining battery life simulating remaining charge When the battery is low and close to power down the laser beam will flash three times every 10 seconds and the display will show blinking battery indicator If the SLPshuts down due to low battery the display will show bA Lo In this case shut the laser off and charge Charge the battery for 7 hours for full charge The first 4 hours will charge fast The laser can be operated when charging In emergency situations as little as 15 minutes of charging will give several hours of battery life A full charge over the week end should give you more than a week s operation If possible stick to this charging scheme If you charge more often it will shorten the life of the battery 1 WHAT S WHAT 8 8 8 8 FIGURE 1 CONTROL PANEL On Off Button Battery indicator Side alignment buttons Side ali