Home

User Manual - GC-SAT

image

Contents

1. 9601 to developer PCB configuration Figure 4 Assembly Item Number Identification Item Numbers in Figure 4 are described in Table 3 Not to scale Dimensions in millimeters Table 3 Item Number Description for Figure 4 Item Type Description Quantity Part M3 Shake proof washer zinc plated steel 4 supplied with item 1 8 M3 Threaded standoff 6 0 A F HEX x 12 00 mm M3 x 8 Pan head screw pozidrive zinc plated steel Solution developer PCB fitted with Samtec connector ESQT 113 02 L D 425 4 y This item is the same item as Item 1 in Figure 5 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Figure 5 Mechanical mounting foot print for use when stacking the 9601 ISU with a developer provided PCB Dimensions in milli meters not to scale Notes for Figure 5 1 Item 1 is a generic developer provided PCB design and shown for illustrative purposes This item is the same as Item 6 in Figure 4 2 Item 2 is available from Samtec in a variety of heights This example shows a 0 425 version The part number for this connector is ESQT 113 02 L D 425 3 Compatible heights of stand offs and variants on Item 2 are as follows a 0 425 height shown fits with 12mm high spacers b 0 327 height is minimum that can be used Fits with 9 50mm spacers c 0 800 height is the maximum height available fits with 21 50mm spacers d Anything else in between should work if Samtec height S
2. controls how the 9601 SBD Transceiver uses DTR e 6If set to AT amp DO DTR is always ignored e Otherwise DTR set to OFF places the data port into UART test mode after 10 seconds or immediately on boot up A subsequent transition of DTR to ON returns the data port to DCE mode and resets it to its power on state Active low handshaking output The 9601 SBD Transceiver drives DSR ON when the data port is in DCE mode and OFF when the data port is in test mode The DTE may use this signal as an indication that the 9601 SBD Transceiver is powered up and ready to receive AT commands Active low ring indicator output The 9601 SBD Transceiver drives RI ON when it receives a ring alert from the network and drives RI OFF after 5 seconds or when the DTE initiates an SBD session whichever occurs first Active low handshaking output DCD is driven ON at all times Note that the Ring Indicator RI pin is used by the 9601 SBD Transceiver to indicate that a Mobile Terminated SBD MT SBD message is queued at the Gateway The Field Application will need to monitor this pin and use appropriate AT Commands to command the Transceiver to retrieve the MT SBD message RX TX CTS DTR DSR DCD The serial interface may be operated with a 3 wire connection where only transmit receive and ground signals are used However the 9 wire interface offers better control and is the recommended implementation Iridium is only able to provide limited 3
3. pins 4 5 amp 6 are tied together at the connector as well as the three Supply pins pins 1 2 amp 3 Multiple signal grounds are provided to reduce cross talk The signal grounds on pins 10 13 20 amp 23 are all tied together at the connector and can be joined with any of the signal wires e g RS232 Network Available etc However each signal requires its own signal ground in order to limit current on any one pin Table 7 Multi Interface Connector Pin Allocation Signal Signal Name direction Signal function Signal level WRT 9601 3 EXT GND Supplyretun OV 5 EXT GND _ Suppyretum OV EXT GND Supplyretun OV On 2 0V to Vsupply 120 pA max Reserved Reserved of G OS 10 SIG GND Signalground DF S TX Data port ga data into 9601 SBD RS 239 ransceiver DF S RX Data port a 9601 SBD RS 990 13 SIGGND SSignalground OV 14 15 16 RS 232 20 SIGGND Signalground O _ ___ 21 Reserved S O 22 Reserved S O 23 SIG GND Signalground O _ ___ NETWORK_ oe eas AVAILABLE Output Set to logic 1 when network is visible 2 9 V CMOS ay ae 12 adl Edo es ee Figure 9 provides a reference for the pin designation Note that this designation is when looking into the multi interface connector from above It is not to scale and not representative of the actual connector mechanical layout 11 Iridium Satellite LLC 9601 Short Burst Data Only Transc
4. wire interface support When operating with a 3 wire connection the following rules apply e AT amp Dn must be set to AT amp DO to ignore the DTR input e AT amp Kn must be set to AT amp KO to disable RTS CTS flow control e The other output signals may be connected and operate as follows e CTS driven ON low e DSR operates as normal e Rl operates as normal e DCD driven ON low The UART test mode is provided for factory testing of the data port UART An FA should never activate test mode if it does the 9601 SBD Transceiver will stop responding to AT commands until the data port is returned to DCE mode 14 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Note RTS CTS flow control when enabled is only used when the data port is in SBD data mode In AT command mode RTS is ignored and CTS is driven ON low 5 3 2 Configuration Settings The 9601 SBD Transceiver allows the DTE to configure the data port communication parameters The three configuration types are active factory default and stored The active configuration is the set of parameters currently in use They can be changed by the DTE individually via specific AT commands The factory default configuration is stored in permanent memory This configuration can be recalled at any time through use of the AT amp Fn command Two groups of settings or profiles can be stored as user defined configurations The DTE first creates desire
5. Note This document is designed to meet the requirements for documentation to be shipped with a product for products shipped to the European Union and other countries It does not replace the 9601 SBD Transceiver Developers Guide Developers should only rely on the Developers Guide for detailed technical information IRIDIUM 9601 Short Burst Data Only Transceiver User s Guide O FO sicbaicom Unit 11 33 Riley Road Woodmead sales gc sat com Iridium Satellite LLC 27 11 612 3660 www gc sat com 6701 Democracy Blvd Suite 500 Bethesda MD 20817 USA Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide Contents O Product QV Ct V6 Wi sostraria sincere teres E O 3 2 0 SANG ALAS Compl ance errre tet aad ae brates rn hata talaWads eae bos caulidln sh apo maaan de omebe aatieds 3 2 1 PCC COMPUN Onera R EEA E SEE aichanteont agin 3 22 CE COmplanCe oeiee ea a n 4 23 Canadian Compliant sacigascee seeds txxin deleted a a ae teed teeta 4 320 PINYSICal SPeCib CAUlOMS nn SE 4 3 1 Dno ON aee e mtn ture eae E E seat Tete rere meter erate erate seat rear nce ter 4 3 2 Mechanical Dimensions MOUNUNG ccice wenden a a a hue oad 5 aa Momniine Stackable Desi monesi A E EA 5 io PAO Mounting to a Panel Surface For use with cable connections cccccseeeeeees 8 4O Eoy Tone Tal lis te choc dich dan daneeee leas usaansls tone ten tune anuetsceraaaineatasensastan dined nasich sen eaaneangende
6. are summarized in Table 11 below Table 11 General RF Parameters 16 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide Vi 1 Parameter Value Frequency Range 1616 MHz to 1626 5 MHz Duplexing Method TDD Time Domain Duplex Oscillator Stability 1 5 ppm Input Output Impedance 500 Multiplexing Method TDMA FDMA 6 3 Radio Characteristics The tables within this section contain radio characteristics of the 9601 SBD Transceiver Table 12 In Band Characteristics Parameter Average Power during a transmit slot max 1 6 W Table 13 Link Margin Configuration Cable Loss Link Margin 9601 SBD Transceiver antennas Note 1 2 dB Note 2 13 1 dB Note 3 Note that the total implementation loss for an antenna connectors cable lightening arrestor and any other RF component between the transceiver and the antenna shall not exceed 3dB Implementation loss higher than this will affect link performance and quality of service Note 1 This Transceiver has a different antenna connector to other Iridium transceivers Note 2 Cable losses should be minimized Note 3 Link Margin given for free space 7 0 Instructions for the safe Installation and use of the 9601 The 9601 is intended for integration into a finished product The integrator of the 9601 is required to connect a power supply antenna and user interface to the 9601 To ensure that the 9601 is correctly installed the fo
7. ccccccssssssseeccceeceeeeeeeeeeecceeeeeeeeseseeeeeeeeaeas 18 90 Export Compliance n ormat ON ssa EEE 18 100 Contacte Indiim sate lite LEC eici a nA 18 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 1 0 Product Overview The Iridium 9601 is a single board transceiver and is essentially provided as a black box transceiver with all device interfaces provided by a single multi pin interface connector in addition to the antenna connector The product only provides the core transceiver All other end user application functions such as GPS microprocessor based logic control digital and analog inputs digital and analog outputs power supply and antenna must be provided by the solution developer The device interface consists of the serial interface power input network available output and power on off control line The Iridium 9601 Short Burst Data Only Transceiver 9601 is designed to be integrated into a wireless data application with other hardware and software to produce a full solution designed for a specific application or vertical market Examples of these solutions include tracking a maritime vessel or automatic vehicle location The 9601 only supports Iridium s Short Burst Data SBD capability It does not support voice circuit switched data or short message service SMS This is a new product and has no functional predecessor The 9601 meets specific regulatory requirements for FCC Canada a
8. cluding this logic output in the application decision logic 5 6 DC Power Output A limited power output can be provided by the 9601 which could be used for driving an LED to provide a visible indication that the transceiver is on or the output could be used in application logic to determine if the transceiver is on 6 0 RF Interface This section describes the physical connector and RF specifications of the RF Interface 6 1 Antenna Connector The 9601 will have the following antenna connector characteristics as described in Table 10 Table 10 Antenna Characteristics Parameter Value Impedance 50 Ohms nominal Gain 3dBi Polarization RHCP VSWR maximum operational 1 5 1 Note e Existing qualified Iridium antennas may be used i e antennas designed for the 9522 and 9601 e Existing antennas will require different RF connector types to those for the 9522 and 9601 6 1 1 Antenna Connector Type The antenna connector on the 9601 is a female SMA type The connector is manufactured by Johnson Components and has a part number 142 0701 871 Additional information can be found at htto www johnsoncomponents com webapp wcs stores servlet ENPProductDetailView itemid 20525 amp st oreld 10010 amp catalogld 10010 amp langld 1 A data sheet may be downloaded from htto www johnsoncomponents com webapp wcs stores Johnson pdfs 1420701871 pdf 6 2 RF Interface Specifications The RF interface requirements for the 9601
9. cnden tusenaauels 9 4 1 iter aCe Conner sites aye anet eat t ce nea ae a E tesae whe eau aaeaan aoe 10 50 electrical Interlace Saena ica aoa iiieet en eect eineeaus 10 5 1 Mult Inter fae CONN CClOk purp den nau ucsieneiecidinadunsatadons denna necenebenctnntuesesasans 10 Sl Connector TYPE E a E nce eae ee eee 10 I2 Connector Pim AIGA OI aia a a he aaereutwetals 11 5 2 1B Ga Bron ol MEIC Cees einer eee eee ram Mee ea RE anaemia ee ee 12 Jl Power ONON COMU ON nse a auaaeeeietel 13 5 3 Deal Data Mer AC e serie e EE E Ee 13 oo Wre and 35 Wire Operatlonnaneien in Na 13 5 32 Configuration Seting Sonesson E E E txoralbalasenetiaxt 15 2s eo Modes OF Oper atl OW ennea E eacceatb eaten e EN teenie 15 34 Hardware Palme REPOND O ocre a E aN niaed theese uae te 15 59 NeMWOK A vada be QUMI a E a nam 16 SO DC POW Ci OUUTE 16 6 0 RETEA CC eai a tan daibstcautcaleeaadalcwaadvaus an Acliceenuna lana salaueaceaus tana 16 6 1 AMEME CONHECO i 8acndc on dhatoesatanetsotdidcntssdanedatrdtatiaantanetsccdidsniasdauedaardiatineatanetsedidcniesaasa 16 6 1 1 Anema Connector PV Pe restra o a aaa ths 16 O2 RPF Interlace Speciet ons eiee hoc sotusu eed 16 6 3 Radio CAPRA C TCT SIC Seriene R NEE 17 7 0 Instructions for the safe Installation and use of the 9601 nnnoosssssnnnnssssssssserrssssssssseeeees 17 7 1 Mastrociions Tortie MEO en ER 17 7 2 Instructions from the integrator to the USE accensis E E 18 8 0 Modem Commands and Configuration cccccc
10. d active configurations and then writes them to memory using the AT amp Wn command These profiles can be designated to be loaded as the active configuration upon 9601 SBD Transceiver power up through use of the AT amp Yn command The 9601 SBD Transceiver can be reset without loss of power to these profiles through use of the ATZn command The configuration settings are stored in S register locations 5 3 3 Modes of Operation The serial interface is always in one of three modes command mode SBD data mode or SBD session mode When the data port is in command mode AT commands can be entered to control the 9601 SBD Transceiver In command mode flow control has no effect with the RTS input ignored and the CTS output driven ON low When in SBD data mode the 9601 SBD Transceiver is transferring binary or text SBD message data to or from the DTE In SBD data mode e All characters from the DTE not forming part of the message data are ignored i e no AT commands may be entered e No unsolicited result codes are issued e RTIS CTS flow control if enabled is active When RTS is OFF high the 9601 SBD Transceiver suspends transfer of data to the DIE when CTS is OFF high the 9601 SBD Transceiver expects the DTE to suspend transfer of data to the 9601 SBD Transceiver When in SBD session mode the 9601 SBD Transceiver is attempting to conduct an SBD session with the network In SBD session mode e The DTE must wait for the SBDI sessio
11. eiver User s Guide V1 1 02 26 01 03 25 Connector notch Figure 9 Multi Interface Connector Pin Number Designation Notes for figure 9 View looking into connector from above Numbers indicate pin designations Not to scale for illustrative purposes only Note location of connector notch Connector notch faces towards opposite end to the antenna connector as shown in Figure 10 On the physical connector Pin 1 is indicated by an arrow mark ae a Notch on connector is on this side Figure 10 Multi Interface Connector Notch Location 5 2 DC Power Interface The DC power interface is comprised of the DC power inputs and a control signal as summarized in Table 7 The three 5V Inputs and three OV supply returns are used to supply DC power to the 9601 and ensure that enough current can be drawn across the connector without the 9601 malfunctioning during transmit due to lack of current supply Note that all six pins should be connected The DC power supply requirements for the 9601 are summarized in Table 8 below Note that these requirements apply to DC power measured at the 9601 multi interface connector input and not at the output of the power supply Long power supply cables can cause a voltage drop sufficient to cause the voltage to be out of specification at the physical power supply input to the 9601 12 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Table 8 DC Power Input Spec
12. ifications Parameter Value Main Input Voltage Range 4 5 VDC to 5 5 VDC Main Input Voltage Nominal 5 0VDC Main Input Voltage Ripple 40 mV pp Input Standby Current average 100mA Peak Transient Current Transmit lt 2 0A Current Average when SBD message transfer in process lt 350 mA Average Power consumption when SBD message transfer in process lt 1 75 W Note The average power consumption depends on the view of the satellite constellation from the antenna The external power supply needs to guarantee the following e The supply voltage droop over an 8 3mS burst should not be more than 0 2 Volts e The power supply should limit the in rush current to 4 Amps maximum e The supply noise should be less than that in the following profile linear interpolation between these points 100 mV pk pk OHz to 50 kHz 5 mV pk pk in 50 kHz bandwidth at 1 MHz 10 mV pk pk in 1 MHz bandwidth at 1 MHz J 5 mV pk pk in 1 MHz bandwidth above 5 MHZ 5 2 1 Power On Off Control An external on off input is provided on a pin of the multi interface connector The 9601 starts up when power is applied and the power on off input is high As long as the input voltage is applied logic high on this line turns the transceiver on and a logic low turns it off If this line is not required then it must be connected directly to the 5 V supply The input logic high threshold is 2 0 V and the logic
13. ium Satellite LLC Iridium Satellite LLC Headquarters 6701 Democracy Blvd Suite 500 Bethesda MD 20817 USA Phone 1 301 571 6200 Fax 1 301 571 6250 Iridium Satellite LLC 8440 S River Parkway Tempe AZ 85284 Toll Free 1 866 947 4348 Local or International 1 480 752 5155 Fax 1 480 752 1105 email info iridium com www iridium com 18
14. iver User s Guide V1 1 Table 4 Item Number Description for Figure 7 Item Type Description 9601 SBD Transceiver Mounting Plate or Surface developer provided Figure 8 Mechanical mounting foot print for use when panel mounting 9601 Dimensions in milli meters not to scale 4 0 Environmental The environmental specifications of the 9601 are summarized in Table 5 below Table 5 Environmental Specifications Parameter Value Operating Temperature Range 30 C to 60 C Operating Humidity Range lt 75 RH Storage Temperature Range 40 C to 85 C Storage Humidity Range lt 93 RH The 9601 has been tested to the specifications listed in Table 6 Quantity Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Table 6 Environmental Tests Test Name Test Reference Test Description Change of Temperature Thermal Shock EN60068 2 14 2000 25C to 70C 5 cycles of 1 hour each Damp heat steady state 40C 93 RH for 4 days Humidity IEC60068 2 3 1969 Shock EN60068 2 27 1993 NF c20 727 Shock J1455 Society of Automotive Engineers Vibration EN 60068 2 36 1996 Sinusoidal Vibration 0 96 m2 s3 from 5Hz to 20Hz Sinusoidal Vibration Vibration IEC 60068 2 36 1996 21Hz to 500Hz 3dB per octave Vibration J1455 Society of Automotive Engineers 4 1 Interface Connectors The 9601 SBD Transceiver incorporates two connectors e A
15. ld void the user s authority to operate the equipment IMPORTANT To comply with FCC RF exposure requirements a minimum separation of 20 cm is required between the antenna and all persons Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 2 2 CE Compliance This product when marked with the CE symbol complies with the European Community Council Directive for R amp TTE 99 5 EC provided that the integrator user adheres to the instructions detailed in this Interface Specification This product is in compliance with applicable ETSI standards Compliance with the requirements of ETSI EN 301 489 requires the use of a shielded digital data interface cable 2 3 Canadian Compliance The 9601 is certified under RSS 170 of the Canadian Radio standards as IC 4629A 9601 Operation is subject to the condition that this device does not cause harmful interference Any changes or modifications including the use of a non standard antenna not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 3 0 Physical Specifications For illustrative purposes a rendering of the 9601 ISU is shown in Figure 1 with a ribbon cable connector inserted Note that 9601 this ribbon cable connector is to be provided by the developer and is not supplied as part of the product Figure 1 The 9601 SBD Transceiver 3 1 Dimensions The overall dimensions of the 9601 and its
16. llowing general instructions sub section 5 1 are provided for the installer The integrator will be required to supply the end user of the integrated product incorporating the 9601 with operating instructions and any other information relating to the maintenance and safety of the equipment sub section 5 2 7 1 Instructions for the Integrator e The 9601 must be installed by an appropriately qualified installer and mounted securely as described in section 3 4 of this document e he power supply used to power the 9601 must be checked to ensure it meets the requirements of sub section 4 1 2 of this document e Electrical connections to the 9601 multi interface connector shall be as designated in Table 3 of sub section 3 3 1 of this document e The current and voltage rating of the multi interface connector cable shall meet the requirements of the DC power input e The electrical characteristics of the multi interface connector cable shall not degrade the 9601 digital communications and analog audio signals e The multi interface connector cable will provide adequate screening from external electromagnetic 17 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 interference e The 9601 shall not be located in close proximity to sources of extreme temperature which will cause it to be operated outside of its temperature specification e The 9601 shall not be operated without an appropriate antenna connected
17. low threshold is 0 5 V Note that this on off control is not the same as the 9522A SBD Modem 5 3 Serial Data Interface The Serial data interface is used to both command the 9601 and transfer user data to and from the Transceiver The 9601 presents a 9 wire data port to the FA Field Application where the interface is at RS232 levels With respect to this interface the 9601 SBD Transceiver behaves as a DCE Data Communication Equipment and the FA behaves as a DTE Data Terminal Equipment The terms FA and DTE are used interchangeably throughout this document similarly for the terms 9601 SBD Transceiver and DCE Autobaud is not supported in 9601 SBD Transceiver The baud rate can be set via the AT IPR command The default rate is 19200 bps 5 3 1 9 Wire and 3 Wire Operation By default the serial interface operates as a 9 wire connection Table 9 describes each of the signals where input means an input to the 9601 SBD Transceiver and output means an output from the 9601 SBD Transceiver 13 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Table 9 Serial Interface Signals Signal Description RX Active high data input TX Active high data output OV Active low flow control input Active low flow control output RTS and CTS are used together to implement hardware flow control when enabled with AT amp K3 Active low handshaking input AT amp Dn
18. multi interface connector e An antenna connector These interfaces are described in more detail in Sections 5 and 6 respectively 5 0 Electrical Interfaces The subsections to follow contain information for the electrical interfaces of the 9601 SBD Transceiver 5 1 Multi lnterface Connector The multi interface connector includes six interfaces DC power supply input Power on off control RS 232 Serial data Network available output 5 1 1 Connector Type The connector on the 9601 is a Samtec EHT series This connector provides the ability for both a cable connector as well as a stackable board to board connection For cable connected applications use the Samtec TCSD series For PCB stacking use the Samtec ESQT series Data sheets on these connectors can be found at EHT Series http Wwww samtec com technical_specifications overview asp series EH 1 TCSD Series http www samtec com technical_ specifications overview asp series tcsd ESQT Series http Wwww samtec com technical_specifications overview asp series esat 10 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 5 1 2 Connector Pin Allocation The user connector is a 2 row 26 way latching header Individual pin assignments are shown in Table 7 Multiple supply grounds are provided and all supply and supply grounds pins 1 6 are required to be connected to the power supply in order to limit the current on any one pin The three Supply Returns
19. n result code e All characters from the DTE are ignored e Unsolicited result codes are issued where those codes have been enabled Transitions between the modes of operation are performed automatically by the 9601 SBD Transceiver in response to the SBD AT Commands the DTE has no other control over the mode 5 4 Hardware Failure Reporting lf the 9601 SBD Transceiver detects a hardware problem during initialisation the 9601 SBD Transceiver may be unable to function correctly The 9601 SBD Transceiver notifies the DTE of this situation by issuing an unsolicited result code at the end of initialisation HARDWARE FAILURE lt subsys gt lt error gt where lt subsys gt identifies the software subsystem that detected the error and lt error gt is the subsystem specific error code Any AT commands that cannot be handled in the failure condition will terminate with result code 4 ERROR 15 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 5 5 Network Available Output This is a digital output that can be used by an application to know when the Transceiver has visibility to the satellite network This is useful in applications where the Transceiver may move around terrain that reduces the amount of time that clear line of sight to the satellite constellation is available The application developer can use this output to preserve battery life by reducing the number of attempted transmissions by in
20. nd CE assuming an antenna with a gain of 3 dBi This allows the 9601 to be integrated into a variety of wireless data applications or retrofitted into existing SBD only applications that utilize SBD with the Iridium 9601 or 9522 L Band Transceiver based products Such finished products when integrated together require regulatory testing to be conducted by the integrator The 9601 does not incorporate nor require a Subscriber Identity Module also Know as a SIM Card to be inserted into the transceiver 1 1 Key Features Single board transceiver Small form factor No SIM card Designed to be incorporated into an OEM solution Maximum mobile originated message size 205 bytes Maximum mobile terminated message size 135 bytes Uses small omni directional antenna Global operating capability FCC Industry Canada CE certified 2 0 Standards Compliance The 9601 is designed to comply with the standards for Radio Emissions Compliance Electromagnetic Compatibility and AC Safety in the United States European Union and Canada 2 1 FCC Compliance The 9601 is certified under 47 CFR Part 25 as FCC ID Q639601 It also complies with Part 15 of the FCC Regulations Operation is subject to the condition that this device does not cause harmful interference Any changes or modifications including the use of a non standard antenna not expressly approved by the party responsible for compliance cou
21. pacer height minus 1 20mm 4 Suggested examples of spacer types and compatible fasteners a M3 threaded thru hole 6 0 A F Hex x 12mm re use M3 x 20 shipping screws and washers add M3 x 8 screws and washers b Plain thru hole diameter 3 2 3 5 diameter 6 0 x 9 50mm replace M3 x 20 shipping screws with M3 x 30 screws same nuts and washers c Plain thru hole diameter 3 2 3 5 diameter 6 0 x 21 50mm replace M3 x 20 shipping screws with M3 x 35 screws same nuts and washers Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 3 2 2 Mounting to a Panel Surface For use with cable connections An example of mounting to a panel or other surface design is shown in Figure 6 Figure 6 9601 SBD Transceiver mounted to a plate or surface The figures and tables below provide mechanical information design information for a mounting a 9601 to a plate or surface configuration 13 0 5 Figure 7 Assembly Item Number Identification ltem Numbers in Figure 7 are described in Table 4 Not to scale Dimensions in millimeters Notes for Figure 7 1 Item 1 includes 4 off M3 x 20 shipping screws shake proof washers and nuts 2 Shipping screws can be used to attach Transceiver to panel of 2 00 mm maximum thickness 3 Panels thicker than 2 00mm require longer screws to be e g M3 x 25mm 4 See Figure 8 for mounting hole dimensions Iridium Satellite LLC 9601 Short Burst Data Only Transce
22. to its Antenna connector This antenna shall be sited at least 20cm away from any person 7 2 Instructions from the integrator to the user To comply with the requirements of sub clause 1 7 2 Safety instructions of the European Information technology equipment safety standard EN60950 1 2002 the integrator must ensure that Sufficient information shall be provided to the USER concerning any condition necessary to ensure that when used as prescribed by the manufacturer the equipment is unlikely to present a hazard within the meaning of this standard If it is necessary to take special precautions to avoid the introduction of hazards when operating installing servicing transporting or storing equipment the necessary instructions shall be made available As part of these instructions the installer should inform the user that they should not service the 9601 8 0 Modem Commands and Configuration The 9601 is configured through the use of AT commands A full listing of the supported AT commands can be found in the 9601 AT Command Reference document 9 0 Export Compliance Information This product is controlled by the export laws and regulations of the United States of America The U S Government may restrict the export or re export of this product to certain individuals and or destinations For further information contact the U S Department of Commerce Bureau of Industry and Security or visit www bis doc gov 10 0 Contacting Irid
23. weight are summarized in Table 2 and represented graphically in Figure 2 Table 2 9601 Mechanical Dimensions Parameter Value Length 106 mm Width 56 2 mm Depth 13 mm Weight approximate 117g Note that these dimensions are for the enclosure and do not take into account the connectors or mounting hardware Additionally developers should plan for additional space for the reciprocal connectors for the Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 antenna and user connector 106 Figure 2 Dimensions of the 9601 SBD Transceiver Notes e The SMA Antenna connector is 10mm long e The Samtec user connector rises 6 mm above the enclosure 3 2 Mechanical Dimensions Mounting The 9601 SBD Transceiver is provided with four mounting holes one at each corner During manufacture four screws are inserted for shipping purposes These screws need to be removed for mounting There are two basic options for mounting stackable and mounting to a surface such as a mounting plate or enclosure wall The following sections provide further information 3 2 1 Mounting Stackable Design An example stackable design is shown in Figure 3 Iridium Satellite LLC 9601 Short Burst Data Only Transceiver User s Guide V1 1 Figure 3 9601 SBD Transceiver mounted to a unpopulated PCB The figures below provides mechanical information design information for a suitable stackable

Download Pdf Manuals