1. 18 0 138 1 Minutes 138 0 Minutes 29 30 APPENDIX SMS COMMANDS LIST APPENDIX SMS COMMANDS LIST Category Function Command Enable auto control time date 4128414 unction Timing Set the time period for the output 129 WorkDay StartTime Control control to switch ON OFF EndTime Disable auto control time date 128 0 unction Default Enable auto control temperature 159 1 unction Temperature Set the temperature period for the 159 Mode Lowlemp Control output control to switch ON OFF HighTemp a De 159 1 w ae la Notifications No SMS notification upon the socket 1104 output changing Check the socket s operating status 07 Check the socket s output status 20004 Checking the Check the socket s delayed output 41384 Status parameters Check the socket s time date 41284 parameters Check the sockets temperature 159 parameters Reset to Factory Reset the socket 08 Settings Sensor de temperatura Toma de corriente Led indicador funci n de control remoto Enchufe Puerto de datos Puerto sensor de temperatura Pulsador M interruptor de alimentaci n alojamiento tarjeta SIM Enchufe con Sonda de temperatura para calefacciones GSM EU Aire eee Acondicionado OM nl 16Amp a elinstaladorelectricista
2. The socket has power and the GSM LED light keeps flashing The socket is replying The master number already exists The socket is replying Invalid format please check and try again later The socket is replying No authorisation user Possible Reason The socket has no power supply The socket can t find or identify the SIM card There is no power available or the power socket is off There are insufficient funds on the SIM card Possible GSM socket fault The network signal is weak or the network is busy The SIM card is locked The SIM card is not active Another master user is already programmed The command you have entered is not in the right format or the command does not exist The user is not preset within the socket Solution Check that there is external power available The SIM card is not installed correctly power off the socket check the SIM card is inserted correctly then turn the power socket back on Check that there is external power available or turn the power socket on Top up the SIM card with credi Turn the power socket off check the SIM card or reset to factory settings Try the socket in an area where the signal is stronger Unlock the SIM card Check with the network provider that the SIM card is still active Send the command to change the master user Refer to the user manual Refer to the user manual 27 CHAPTER
3. 2 QUICK START 13 CHAPTER 2 QUICK START 2 1 INSTALLING THE SIM CARD AND TEMPERATURE SENSOR 1 The power switch should be in the OFF position See 7 on Figure 1 please make sure the power socket is off before inserting the SIM Card 2 1 INSTALL THE SIM CARD AND TEMPERATURE SENSOR 2 Open the socket s SIM cover you will see a SIM card holder See 8 on 2 2 TURNING THE SOCKET ON OFF Figure 1 2 3 USER AUTHORISATION LEVEL 3 Slide the metallic cover of the holder in the direction of OPEN then lift 2 4 SETTING THE MASTER NUMBER he metallic cover up and towards you 2 5 SETTING THE DATE TIME GMT 4 Put the SIM card with the gold contacts face down and the slight corner cut out of the SIM at the bottom left 28 CONTROLLING THE OUTPUT POWER 5 Slide back the metallic cover in the direction of LOCK and make sure 2 7 NOTIFICATION OF POWER SUPPLY LOSS he SIM card locks into place 6 The SIM card will be fixed in the holder N Insert the temperature sensor into the I O port see 3 Figure 1 2 2 TURNING THE SOCKET ON OFF 1 Turn the power switch to ON position see 7 on Figure 1 2 Plug the GSM power socket into a UK 13 Amp Schuko socket 3 The Green power light will illuminate and the Blue GSM light will flash for about 20 seconds before staying on constantly to confirm GSM signal is available PLEASE MAKE SURE THE SIGNAL IN THE AREA IS GOOD 4 The socket is now ready to be programmed for re
4. Delay Control Function OFF Check socket output status 000 After receiving the SMS command the GSM power socket will send an SMS message confirming the sockets output status LE Status ON Temp 20 Check delayed switch on off the socket parameters 138 After receiving the SMS command the GSM power socket will send an SMS message confirming the sockets delay output status I E Status ON Output will cut off after 5 minutes I E Status ON Delay Control function OFF Check Control output by time date function parameters 128 After receiving the SMS command the GSM power socket will send an SMS message confirming the Time Date control parameters I E Schedule control function ON Monday 12 00 15 00 I E Schedule control function OFF Monday 12 00 15 00 Check temperature range control of parameters 159 After receiving the SMS command the GSM power socket will send an SMS message confirming the temperature control parameters I E Status OFF Temp Control OFF Temp 24 Mode Heating Range 20 30 If No temperature sensor connected is received it means the GSM power socket cannot detect the temperature sensor please check if the temperature sensor is inserted to the I O port CHAPTER 3 ADVANCED SETTINGS 3 8 RESETTING THE SOCKET This function resets all programmed settings to their original parameters including deleting all additional users numbers ti
5. INSTRUCTIONS Auto operation by pre set time times days 1 4 TEMPERATURE SENSOR INSTRUCTION The GSM power socket is supplied with a plug in external temperature sensor 1 5 LIGHT INDICATORS Automatic operation by pre set upper lower temperature thresholds on off Receive temperature reading in the location via a simple SMS command Supports 1 master and 4 additional numbers users Automatic time date synchronization Receive SMS message on external power failure 1 2 LIST OF CONTENTS e 1x GSM power socket e 1 x External plug in temperature sensor e 1 x User manual 10 CHAPTER 1 FEATURES AND ACCESSORIES 1 3 SCHEMATIC DRAWINGS Data port Temperature sensor port Om button O Electrical outlet Indicator light Power GSM Output O Socket plugs O Power switch 6 SIM card holder Figure 1 GSM socket instructions CHAPTER 1 FEATURES AND ACCESSORIES 1 4 TEMPERATURE SENSOR DRAWING Temperature sensor Standard 3 5mm interface Figure 2 Temperature Sensor Drawing 1 5 LED LIGHT INDICATORS KEY Indicator Action Status No Light No Mains Power Available Power Light Green LED Constant Light Mains Power Available No Light ae GSM Signal Socket Switched GSM Blue Light Flashing Light ae GSM Network Sending Socket Power to Connected Device No Light Output Light OFF Red LED c Socket Power to Connected Device onstant ON 11 CHAPTER 2 QUICK START CHAPTER
6. e in the winter when the temperature is low and the device might be used to turn a heater on to keep the environment warm the mode is heating command code is 0 When the environment temperature goes below than the minimum set value it will turn on the output power on Then when it has reached the maximum set value the output will be cut off Cooling Description When connecting a cooling device to the GSM power socket i e in the summer when the temperature is high and the device might be used to turn on an air conditioning unit to keep the environment cool the mode is cooling command code is 1 When the environment temperature goes above the maximum set value it will turn the output power on Then when it has reached the minimum set value the output will be cut off Heating To set the temperature control parameters the master user sends the following SMS command 159 0 MinimumTempValue MaximumTempValue LE 15940 10 20 When the room temperature is lower than 10 degrees the output power to the device will automatically turn on but when it has reached 20 degrees then the output will be turned off automatically If temperature drops below 10 degrees again the output will be switched on CHAPTER 3 ADVANCED SETTINGS Cooling To set the temperature control parameters the master user sends the following SMS command 159 1 MinimumTempValue MaximumTempValue LE 1594 1 20 30 When the temperature i
7. power on or off according to the environment temperature It is suitable for power control of heating or cooling equipment by keeping the environmental temperature within a pre set range or at a fixed temperature value All services and functions need to be supported by the GSM network and a SIM card This instruction manual provides both a quick start set up and also more advanced settings if the user wishes to programme the GSM power socket by temperature or time date CONTENTS Imponan TATOMMATOM casada li calcio Safety Recommendations xa Disclaimer NOICE maras CHAPTER 1 FEATURES AND ACCESSORIES LA Mai AA on AP A TS GOMA DMWINGS sac croctaaisctasesnceradeensharcatsludessssmrargabadaccsameasieass 1 4 Temperature Sensor Drawing i 1SM ED Light Indicators KEY conoci ica coco E pe CHAPTER 2 QUICK START 214 Installing the SIM Card and Temperature Sensor iinnnnnnnnnaciiccinoo 13 22 Tumming the Socket ON OM aver irc incre declaraci n 13 23 User Authorisation Levels sies ceroesioirrohgoie nasip heide 14 2 4 Setting the Master Number 2 5 Setting the Date Time GMT 2 6 Controlling the Output Power sa 2 7 Notification of Power Supply Loss ssssssesresiesierieereereerrerreereere 16 CHAPTER 3 ADVANCED SETTINGS Sit Defining THE USES renies ene aee veneer REA SEER TEENETE 3 1 1 Changing the Master Number accen 3 1 2 Adding an Additional User Number ocnnnncioiiccccccccni
8. 6 MAIN TECHNICAL CHAPTER 6 MAIN TECHNICAL Input Power Socket Output Power Socket Relay Operating Temperature Store Temperature Relative Humidity Communication Protocols Data Interface External Temperature Sensor GSM Working Band Category 110 250v 50hZ Time Max 13 Amp 10 C to 50 C Define the Users 20 C to 60 C 10 90 Without Condensation GSM Phase 2 2 including data operation Switching on off output GSM SIM 1 8V 3 0V Socket manually 10 C to 50 C Delay EGSM900 DCS1800 Control APPENDIX SMS COMMANDS LIST Function Set the socket time Add a master number Change the master number Add an additional number Add several numbers Delete an additional number Delete several additional numbers Delete all additional numbers Switch the socket output ON master Switch the socket output OFF master Switch the socket output ON additional users Switch the socket output OFF additional users Enable the output to switch ON OFF by calling Disable the output to switch ON OFF by calling Default Delay switching ON the output Delay switching OFF the output APPENDIX SMS COMMANDS LIST Command 152 00 14 NewMasterNumber 06 AdditionalNumber 06 AdditionalNumber1 AdditionalNumber4 113 AdditionalNumber 113 AdditionalNumber1 AdditionalNumber4 113 01 02 01 Password 02 Password 18 1
9. Kit Enchufe GSM Caracter sticas e Toma de corriente controlada por mensajes de texto e Env a autom ticamente textos hasta cinco usuarios e Monitores de temperatura y env a texto en valor de preselecci n T e Env a Texto fallo de encendido Restaurada ho e F cil configuraci n de usuario e Tiempo autom tico y fecha de sincronizaci n e Capacidad consumo 16A e Cumple con EMC para Europa Aplicaciones e Control de calefacci n e Reinicio PC servidores etc e Control de Aire Acondicionado e Activar aparatos desactivar por mensaje de texto e Visi n de la temperatura a Distancia e informes CONTENTS Thank you for purchasing the GSM power socket The GSM power socket is a remotely controlled power socket using any 2G Pay as you Go SIM Not Three as they are purely a 3G Network The power supply output of the socket can be turned on or off remotely by SMS Short Message System command or locally controlled by its function buttons It is an intelligent power socket that can be controlled anytime and anywhere by a mobile phone The GSM power socket is designed for any electrical appliance for business or domestic use up to 13 Amp for the UK version and 16 Amp for the Schuko version with a power consumption of up to 3 Kw It can be used for any type of device and IEC13 conversion cables for PCs and Servers are available When used with the plug in temperature sensor the GSM power socket can switch
10. MS command to turn the socket off after 2 minutes the delayed output function will be cancelled This is the same if you set the power socket output to turn on at 9am and turn off at 5pm Monday to Friday and the send an SMS to turn the power socket off at 3pm or by pressing the M button to turn the socket off To reset these functions they need to be turned on again i e by sending 128 1 again the formula does not need to be re entered Sending an SMS command also cancels the temperature range function in the same way as the other examples To delay the output switching ON after a set number of minutes the master user sends the following SMS command 138 1 Minutes To delay the output switching OFF after a set number of minutes the master user sends the following SMS command 138 0 Minutes Minutes are time parameters its range is 0 720 If the minutes are set to 0 the function will be invalid and the current output status of the socket won t be changed 19 20 CHAPTER 3 ADVANCED SETTINGS Successful SMS reply The socket power output is cut off now will switch on after minutes The socket power output is switeh on now will cut off after minutes 3 4 CONTROLLING THE OUTPUT BY TIME DATE 3 4 1 TURNING ON THE CONTROL OUTPUT BY TIME DATE FUNCTION The output of the GSM power socket can be set to switch on for a period To enable the control by date time function the master user must send the fol
11. cket will notify the master Main Electricity Supply Lost together with a temperature reading External power supply restored If the power socket is reconnected with external AC power or the external AC power is restored and the power socket is available again the SMS notification will be sent to the master Main Electricity Supply Restored together with a temperature reading When the external power supply is resumed the output of the GSM socket will keep the same status as that of before the external power supply failure if the power switch of the GSM socket is not turned off For example if the device connected to the GSM power socket was ON before the external power supply was cut off the device will turn back ON when power is restored If the power supply is switched on and off quickly the GSM power socket will send the outstanding SMS messages The GSM power socket will notify the master user when there are any external power changes CHAPTER 3 ADVANCED SETTINGS CHAPTER 3 ADVANCED SETTINGS 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 DEFINING THE USERS 3 1 1 Changing the Master Number 3 1 2 Adding an Additional User Number 3 1 3 Checking Additional User s Number s 3 1 4 Deleting an Additional User Number CONTROLLING THE OUTPUT BY CALLING CONTROLLING THE OUTPUT BY A TIME DELAY CONTROLLING THE OUTPUT BY TIME DATE 3 4 1 Turning ON the Control Output by Time Date Function 3 4 2 Settin
12. e sure it is strong Be sure to keep the password and mobile number safe we recommend you change the pre set password of 1234 and do not disclose this information to anyone other than the authorised users in order to ensure there is no misuse A PAYG SIM Card is required for use in this product please make sure he that SIM Card has credit at all times for this product to be effective Master user s SMS command format code content Additional user s number s command format code content password The password must be a four digit number The original password is 1234 The maximum digits that are allowed for the phone number is sixteen The GSM power socket will reply to the user after it receives an SMS command The symbol must not be ignored when typing an SMS command Do not include any spaces within the commands Although we recommend PAYG SIMS to be used with the GSM power socket contract SIMS can also be used however PAYG SIM s are much more cost effective as the GSM power socket can only send SMS messages 5 SAFETY RECOMMENDATIONS SAFETY RECOMMENDATIONS This socket is designed for business or domestic use for any appliance not exceeding 13 Amps for UK version and 16 Amps for Schuko version or 3 Kw output This socket was designed for indoor use do not use it in a wet chemically aggressive dusty environment o not open up the GSM power socket there are no serviceable parts inside D This socke
13. g the Time Date to Control the Output 3 4 3 Turning OFF the Control Output by Time Date Function CONTROLLING THE OUTPUT BY TEMPERATURE 3 5 1 Turning ON the Control Output by Temperature Function 3 5 2 Setting the Temperature Range to Control the Output 3 5 3 Turning OFF the Control Output by Temperature Function SMS NOTIFICATION UPON THE SOCKET OUTPUT CHANGING CHECKING THE SOCKET STATUS RESETTING THE SOCKET 17 18 CHAPTER 3 ADVANCED SETTINGS 3 1 DEFINING THE USERS 3 1 1 CHANGING THE MASTER NUMBER To change the master number please send the following SMS command to the socket 14 NewMasterNumber 3 1 2 ADDING AN ADDITIONAL USER NUMBER Up to 4 additional user s number s can control this socket Additional users have the authority to turn the socket s output on off To add additional users the master must send the following SMS command 06 AdditionalNumber To add several users at the same time the master must send the following SMS command 06 AdditionalNumber1 AdditionalNumber4 The number required is the additional user s mobile number Successful SMS reply 4 The additional number has been set successfully 3 1 3 CHECKING ADDITIONAL USER S NUMBER S Refer to Chapter 3 7 Check status 3 1 4 DELETING AN ADDITIONAL USER NUMBER To delete an additional user number please send the following SMS command to the socket 113 AdditionalNumber To delete several additional users n
14. lowing SMS command 128 1 Successful SMS reply Schedule control function ON Sunday 00 00 00 00 3 4 2 SETTING THE TIME DATE TO CONTROL THE OUTPUT When the time date has been set successfully the scheduled parameters will be saved in the socket These settings are saved in the GSM power socket and will remain until the socket is reset to factory settings If the socket loses external power or the power switch is turned off these parameters are still saved within the socket To set the time date control parameters the master user sends following SMS command 129 WorkDay StartTime EndTime WorkDay One digit the values lie in the range of 0 to 8 The following table contains the descriptions of each value Value Corresponding Day Value Corresponding Day Value Corresponding Day 7 Everyday 3 Wednesday 6 Saturday 1 Monday 4 Thursday 0 Sunday 2 Tuesday 5 Friday 8 Monday Friday CHAPTER 3 ADVANCED SETTINGS StartTime and EndTime Consists of 4 digits hh mm and works on a 24 hour clock the StartTime and EndTime should be in the same day and the EndTime must be later than StartTime during the period The socket output will switch on at the StartTime and cut off at the EndTime For example 129 1 0000 2130 0000 is 00 00 AM hh mm 2130 is 9 30PM Successful SMS reply The schedule is set successfully WorkDay StartTime EndTime Timing control
15. ming parameters and temperature parameters If the setting status is wrong and you have tried re entering the commands the socket can be reset to it s factory settings Note This function needs to be used carefully as it also erases all setting values To reset the GSM power socket to factory settings the master user sends following SMS command 08 Successful SMS reply Reset the socket to factory setting successfully 25 CHAPTER 4 MAINTENANCE CHAPTER 4 MAINTENANCE a Store and use the remote socket responsibly To maintain the integrity of the GSM power socket do not store or use in areas where there is very high humidity and do not allow water or other liquids into the socket otherwise it might cause a malfunction Do not store or use the socket in a dusty environment Do not use alcohol acetone and other similar solvents to clean it simply wipe with a soft wet cloth Do not attempt to programme it except as instructed if there is a problem please try to resolve it through the general troubleshooting section if the problem cannot be solved contact your supplier CHAPTER 5 GENERAL TROUBLESHOOTING CHAPTER 5 GENERAL TROUBLESHOOTING No 1 General Trouble The power LED has turned off The GSM LED light has turned off The M button is not turning the output on off The GSM power socket won t respond to any commands LED indicators are working The socket is not responding at all
16. mote use Note The unit can be turned off by the switch see 7 Figure 1 when not required for a period of time CHAPTER 2 QUICK START 2 3 USER AUTHORISATION LEVEL All settings can be adjusted via SMS command s The GSM power socket has two levels of control Master User Only the master user has authorisation to use all the features of the GSM power socket Only one master number can be programmed per socket The master number can be changed to another number by sending an SMS command Additional users Four additional users have authorisation to use two commands to switch on or cut off the socket output The other mobile phone users have no authorisation to use the GSM power socket If there are any changes made to the GSM power socket the master user always gets the notifications 2 4 SETTING THE MASTER NUMBER The user must send the following SMS to the socket from their mobile phone they will then become the master Please send the following command to add a master number 00 Successful SMS reply Welcome to the GSM socket Your password is 1234 Failed SMS reply If a user tries to add another master user the GSM power socket will send an SMS stating The master user already exists to change the master number please refer to Chapter 3 1 4 Please note unless otherwise stated SMS commands to the socket can only be sent by the master user CHAPTER 2 QUICK START 2 5 SETTING THE DATE TIME GMT Impo
17. nnns 3 1 3 Checking Additional User s Number s j 3 1 4 Deleting an Additional User Number ocn 3 2 Controlling the Output by Calig oi nnnnnnnnnnnnaciiccnaniinni 3 3 Controlling the Output by a Time Delay e 3 4 Controlling the Output by Time Date aeee 3 4 1 Turning ON the Control Output by Time Date Function 3 4 2 Setting the Time Date to Control the Output 3 43 Turning OFF the Control Output by Time Date Function CONTENTS CONTINUED CONTENTS 3 5 Controlling the Output by Temperature cece eeeeteeeee eens 3 5 1 Turning ON the Control Output by Temperature Function 3 5 2 Setting the Temperature Range to Control the Output 3 5 3 Turning OFF the Control Output by Temperature Function 23 3 6 SMS Notification Upon the Socket Output Changing ve 3 7 Checking the Socket Statys scerna iinei iii eii 3 8 Resetting the SOCKEt niiin direnenen ann En ss CHAPTER 4 MAINTENANCE 26 CHAPTER 5 GENERAL TROUBLESHOOTING cc 27 CHAPTER 6 MAIN TECHNICAL cion 28 APPENDIX SMS COMMANDS LIST occ 29 INFORMATION IMPORTANT INFORMATION Y PLEASE READ THIS IMPORTANT INFORMATION The SIM card mobile number is referred to as the GSM socket number in this manual Before using this socket check if mobile phones can be used in the area We recommend before choosing your network provider you check the signal strength of where the socket is to be located and mak
18. rtant note If the power socket is being used for the first time or it has been reset the master user must set the socket time according to the current time of the SMS centre If the time is not set the power socket will use the original pre set start date time from 00 00 00 1st June 2004 Please send the following command to set the time 152 Successful SMS reply The time of the device has been regulated automatically 2 6 CONTROLLING THE OUTPUT POWER Method 1 Master Please send the following command to turn the power socket output ON 01 Additional User Please send the following command to turn the power socket output ON 01 password Master Please send the following command to turn the power socket output OFF 02 Additional User Please send the following command to turn the power socket output OFF 02 password Successful SMS reply The socket power output has been switched on The socket power output has been switched off Method 2 Press the M button See 3 on Figure 1 on the side of the socket for Ye a second until the output light goes on off and then again to turn the output back on off 15 CHAPTER 2 QUICK START 2 7 NOTIFICATION OF POWER SUPPLY LOSS External power supply lost If the GSM power socket is disconnected from external AC power or a loss of the AC power occurs all functions of the socket are deactivated including the M button and the GSM power so
19. s higher than 30 degrees the output power to the device will automatically turn on but when it has reached 20 degrees then the output will be turned off automatically If the temperature goes above 30 degrees again the output will be switched on 3 5 3 TURNING OFF THE CONTROL OUTPUT BY TEMPERATURE FUNCTION To disable the control by temperature function the master user must send the following SMS command 159 0 Successful SMS reply Auto controlled by external temperature sensor de activated 3 6 SMS NOTIFICATION UPON THE SOCKET OUTPUT CHANGING The GSM power socket will by default notify the master when the socket output has changed The master user can enable disable this SMS notification To disable the SMS notifications the master user must send the following SMS command Turn ON SMS notification s upon the socket output changing Default 11 1 Turn OFF SMS notification s upon the socket output changing 11 0 Successful SMS reply Set no SMS notification when socket output changed Set SMS notification once socket output changed 23 24 CHAPTER 3 ADVANCED SETTINGS 3 7 CHECKING THE SOCKET STATUS To check the socket s operating status the master user sends following SMS command 07 After receiving the SMS command the GSM power socket will send an SMS message confirming the status of the socket LE Number Master Number Status ON Temp 20 Temp Control Function OFF Schedule Control Function OFF
20. t uses wireless signal transmissions please keep it away from electronic equipment that may be likely to cause interference K S eep the socket and its accessories out of reach of children hould the GSM socket not function as detailed in this instruction book please contact your supplier for technical support Ifthe GSM power socket is faulty or the issue cannot be resolved after technical support please contact your supplier DISCLAIMER NOTICE DISCLAIMER NOTICE We operate a policy of continuous development and therefore we reserve the right to make changes and improvements to the design functionally or any part of the socket as described in this document without prior notice For the latest information please contact your supplier We cannot be held responsible in any way should this product be used other than for the intended purpose We accept no responsibility for any loss of income or any damages whether consequential or indirectly and however caused due to the use of this socket CHAPTER 1 FEATURES AND ACCESSORIES CHAPTER 1 FEATURES AND ACCESSORIES 9 CHAPTER 1 FEATURES AND ACCESSORIES 1 1 MAIN FUNCTIONS The GSM power socket uses a PAYG SIM card The GSM power socket is operated remotely by SMS command 1 1 MAIN FUNCTIONALITY Output Max 13 Amp for UK version and 16 Amp for Schuko version 1 2 LISTOF CONTENTS M button To manually control output power on off Time delayed control of output power on off 1 3 SOCKET
21. the socket activated de activated 3 4 3 TURNING OFF THE CONTROL OUTPUT BY TIME DATE FUNCTION To disable the control by date time function the master user must send the following SMS command 128 0 Successful SMS reply Timing control the socket de activated 3 5 CONTROLLING THE OUTPUT BY TEMPERATURE 3 5 1 TURNING ON THE CONTROL OUTPUT BY TEMPERATURE FUNCTION The external temperature sensor must be inserted into the I O port of the GSM socket The output status of the socket can then be controlled by the environment temperature automatically If the GSM power socket is being controlled by the delay function or the time date function the temperature control will only be valid when the socket output is on To enable the control by temperature function the master user must send the following SMS command 159 1 21 22 CHAPTER 3 ADVANCED SETTINGS Successful SMS reply Auto controlled by external temperature sensor activated 3 5 2 SETTING THE TEMPERATURE RANGE TO CONTROL THE OUTPUT When the temperature function has been set successfully the scheduled parameters will be saved in the socket These settings are saved in the GSM power socket and will remain until the socket is reset to factory settings If the socket loses external power or the power switch is turned off these parameters are still saved within the socket Heating Description When connected a heating device to the GSM power socket i
22. umbers please send the following SMS command to the socket 113 AdditionalNumber1 AdditionalNumber4 To delete all users additional numbers please send the following SMS command to the socket 113 Successful SMS reply Additional numbers have been deleted Failed SMS reply 4 The additional number does not exist CHAPTER 3 ADVANCED SETTINGS 3 2 CONTROLLING THE OUTPUT BY CALLING If the master user calls the GSM power socket the socket output will be switched on off automatically when the user hears the ring tone in the phone The call will end automatically if the user doesn t hang up the call By default this function is de activated first the function needs to be enabled To enable this function please send the following SMS command 18 1 To disable this function the master user sends the following SMS command 18 0 Successful SMS reply Control the socket power output status by calling de activated Control the socket power output status by calling activated 3 3 CONTROLLING THE OUTPUT BY A TIME DELAY The GSM power socket can be set by SMS command so there is a delay in turning on or turning off the output of the socket NOTE When the Delayed output function is applied the pre set timed switching of the socket output function will be overridden When any functions of the socket are over ridden i e if the socket output is delayed to turn off after 10 minutes and then you send an S