Storport Miniport Driver

image

Contents

1. Storport Miniport Driver User Manual Page 43
2. Install from a list or specific location Advanced Click Next 10 Select Don t search will choose the driver to install Click Next Note Using the OEMSETUP INF file to update Emulex s Storport Miniport driver overwrites customized driver settings If you are upgrading from a previous installation write down the settings Following installation use the HBAnyware utility to restore the pre upgrade settings 11 Click Have Disk Direct the Device Wizard to the location of oemsetup inf If you have downloaded the Storport Miniport files to the default directory the path will be C Program Files Emulex AutoPilot Installer Drivers Storport x86 for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport x64 for the x64 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport lA64 for the Itanium 64 bit driver version 12 Click OK Select Emulex LightPulse LPX000 PCI Slot X Storport Miniport Driver your HBA model will be displayed here 13 Click Next 14 Click Finish The driver installation is complete The driver should start automatically If the HBA is connected to a FC switch hub or data storage device a blinking yellow light on the back of the HBA will indicate a link up condition Manually Installing the Driver Utilities Running this executable installs the HBAnyware utility The Emulex Storport Miniport driver and the ElxPlus
3. Information level e DbgLvilnfo 0x00000008 excessive information level Note To view trace messages you must enable Event Tracing in the operating system See your Microsoft operating system documentation for more information Table 5 Event Tracing Summary Table a From To acter Verbose Description ELS 0100 0130 0199 ELS events Discovery 0202 0262 0299 Link discovery events Mailbox 0310 0326 0399 Mailbox events INIT 0400 0463 0499 Initialization events FCP 0701 0749 0799 FCP traffic history events Link 1300 1306 1399 Link events Tag 1400 1401 1499 NPIV 1800 1804 1800 N Port ID virtualization events Storport Miniport Driver User Manual Page 26 X EMULEX Event Trace Messages ELS Log Messages 0100 0130 lpfc_mes0100 0100 FLOGI failure ulpStatus x x ulpWord 4 x x DESCRIPTION An ELS FLOGI command that was sent to the fabric failed SEVERITY Error LOG LOG_ELS verbose ACTION Check fabric connection SEE ALSO Ipfc mes0110 Ipfc mes0101 0101 FLOGI completes successfully NPortld x x RaTov x x EdTov x x DESCRIPTION An ELS FLOGI command that was sent to the fabric succeeded SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational SEE ALSO Ipfc_mes0110 Ipfc mes0102 0102 PLOGI completes to NPortld x x DESCRIPTION The HBA performed a PLOGI into a remote NPort SEVERITY Information LOG LOG_ELS verb
4. 0737 SCSI check condition SenseKey x x ASC x x ASCQ x x SrbStatus X X DESCRIPTION The issued FCP command resulted in a Check Condition SEVERITY Warning LOG LOG FCP verbose ACTION Review SCSI error code values SEE ALSO Ipfc mes0730 0747 Target reset complete Pathld x x Targetld x x Did x x DESCRIPTION A target reset operation has completed SEVERITY Warning LOG LOG FCP verbose ACTION Review system configuration Possible side effect of cluster operations REMARK See also Message 0713 Storport Miniport Driver User Manual Page 34 X EMULEX 0748 Lun reset complete Pathld x x Targetld x x Lun x x DESCRIPTION A LUN reset operation has completed SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations REMARK See also Message 0703 0749 Abort task set complete Did x x SCSIId x x DESCRIPTION A task management has completed SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations REMARK See also Message 0701 Link Log Messages 1302 1306 Ipfc mes1302 1302 Invalid speed for this board d forced link speed to auto DESCRIPTION The driver is re initializing the link speed to auto detect SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION None required lpfc_mes1303 1303 Link Up event tag x x link speed dG topology 0 Pt2Pt 1 AL
5. AutoPilot Installer in unattended mode Important Considerations Changing Driver Types e Ifyou currently use a driver type different from the one you will install with AutoPilot Installer you will lose your customized driver parameters persistent bindings LUN masking and LUN mapping when you change driver types The AutoPilot Installer default parameters will usually be the best options for the new driver type You may want to note your current settings before you install the new driver type After you have installed the new driver type you can then update your customized driver parameters Microsoft Storport Driver Update e See the Emulex Web site for required updates to the Microsoft Storport driver Storport Miniport Driver User Manual Page 1 X EMULEX AutoPilot Installer Terminates with Legacy HBAs Installed e f any Emulex LP6000 or LP7000 HBAs are installed on the server the AutoPilot Installer installation will terminate It will be necessary to remove the LP6000 and LP7000 HBAs in order to complete the installation Updating the Storport Miniport Driver Using AutoPilot Installer e f you currently have an older version of the Storport Miniport driver version 1 11a3 or older use the hardware first installation method to update your driver Steps 1 and 2 involve installing a new HBA therefore begin at step 3 to update the driver e You can also update the Storport Miniport driver by the manual installation method If
6. Warning LOG LOG ELS verbose ACTION Review system configuration Ipfc mes0232 0232 Continue discovery at sequence number d PLOGIs remaining d DESCRIPTION NPort discovery sequence continuation SEVERITY Information LOG LOG ELS verbose AGTION No action needed informational lpfc_mes0235 0235 New RSCN being deferred due to RSCN in process DESCRIPTION An RSCN was received while processing a previous RSCN SEVERITY Information LOG LOG ELS verbose ACTION No action needed informational Ipfc mes0236 0236 Issuing command to name server type x x DESCRIPTION The driver is issuing a nameserver request to the fabric Also recorded if a GID_FT is sent SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational SEE ALSO Ipfc_mes0239 or Ipfc_mes0240 lpfc_mes0238 0238 NameServer response DID count d DESCRIPTION Received a response from fabric name server with N DIDs SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0239 0239 NameServer Response next DID value x x DESCRIPTION The driver received a nameserver response And this message is recorded for each DID included in the response data SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational SEE ALSO Ipfc_mes0236 lpfc_mes0240 0240 NameServer Response Error CmdRsp x x ReasonCode x x Expla nation x x DESCRIPTION Th
7. d DESCRIPTION A link up event was received It is also possible for multiple link events to be received together SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check physical connections to the FC network REMARKS Ipfc mes1304 is recorded if Map Entries gt 0 and corresponding mode and SEVERITY level is set Ipfc_mes1305 1305 Link down even tag x x DESCRIPTION A link down event was received SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check physical connections to the FC network Ipfc mes1306 1306 Link Down timeout DESCRIPTION The link was down for greater than the configuration parameter HLinkTimeOut seconds All I O associated with the devices on this link will be failed SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION Check HBA cable connection to FC network Storport Miniport Driver User Manual Page 35 X EMULEX Tag Messages 1400 1401 Ipfc mes1400 1400 Tag out of range ContextIndex x x MaxIndex x x ulpCommand x x DESCRIPTION Firmware has generated an invalid response SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION Review hardware configuration Contact Emulex Technical Support Ipfc mes1401 1401 Invalid tag ContextIndex x x ulpCommand x x DESCRIPTION Firmware has generated an invalid response SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION Review hardware configuration
8. goto badcfg echo Invalid configuration file parameters goto serverlok badcfg if not errorlevel 2 goto serverlok echo No appropriate driver found serverlok remd server2 g autopilot ApInstall g autopilot mysetup apinstall cfg if errorlevel 1 goto server2ok echo AutoPilot reported an error upgrading Server 2 if not errorlevel 2147483650 goto unsupported echo Configuration file missing goto server2ok unsupported if not errorlevel 2147483649 goto older echo Unsupported operating system detected older2 if not errorlevel 2001 goto none2 echo The driver found is the same or older than the existing driver goto server2ok none2 if not errorlevel 1248 goto noreport2 echo No HBA found goto server2ok noreport if not errorlevel 110 goto nocfg2 echo Could not open installation report file goto server2ok nocfg2 if not errorlevel 87 goto badcfg2 echo Invalid configuration file parameters goto server2ok badcfg2 if not errorlevel 2 goto server2ok echo No appropriate driver found server2ok Storport Miniport Driver User Manual Page 19 X EMULEX Manually Installing or Updating the Storport Miniport Driver Overview You can install or update the Storport Miniport driver and utilities manually without using AutoPilot Installer The Emulex PLUS ElxPlus driver supports the HBAnyware utility persistent binding and LUN mapping and masking The ElxPlus driver must be installed before you install the Storport Miniport driver R
9. required section can specify driver parameters Parameters are read exactly as they are entered and are written to the registry SYSTEM PARAMS This section may be created to specify system parameters Mandatory Configuration File Changes Locate the Mandatory Configuration File Changes heading in the AUTOPILOT CONFIG section of the APInstall cfg file Enabling Silent Mode You may enable silent mode to run an unattended installation To enable silent mode remove the semicolon before SilentInstallEnable TRUE Setting Up Allowable Driver Types Two configuration file settings determine what driver types the AutoPilot Installer can install Remove the semicolon before win2003DriverPreference STORPORT win2003AllowableDrivers STORPORT Note These two settings must specify the same driver type Windows Vista and Windows Server 2008 systems automatically use the Storport for the win2003DriverPreference and win2003AllowedDrivers parameters Setting Up Driver Location In silent mode you need to specify the location of the driver to be installed Locate the following line in the APInstall cfg file LocalDriverLocation C Path toThe Storport Package Storport Miniport Driver User Manual Page 12 X EMULEX Remove the semicolon before this line and modify this path to reflect the location of the driver The driver location can be a local disk or a network shared drive It can also be a relative path
10. sent SEVERITY Information LOG LOG FCSP verbose ACTION No action needed informational 1902 Receives x x from x x in state x x DESCRIPTION Receives an ELS AUTH CMD SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1903 Receives ELS_AUTH_RUJT x x x x DESCRIPTION Receives an ELS AUTH REJECT SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1904 Authentication ends for x x with status x x d d DESCRIPTION Authentication is done SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1905 Authentication policy change for local x 08x x 08x remote x 08x 08x DESCRIPTION Authentication policy has been changed SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational Error Log Viewing the Error Log The system event log is a standard feature of Windows Server 2003 To view the error LOG 1 Open the Event Viewer window e Click Start gt Programs gt Administrative Tools gt Event Viewer or e Right click on My Computer Manage and Event Viewer in Computer Management Storport Miniport Driver User Manual Page 37 X EMULEX The Event Viewer window is displayed 2 Double click any event with the source name ELXSTOR 3 Examine the entry at offset 0x10 and Event ID 11 Severity Scheme When the Event Viewer is launched there are three branches Application Security and Sy
11. to the apinstall cfg file The location must be specific to the x86 x64 or IA64 folder to install the correct driver for the server platform Full path example for an x86 driver all on one line LocalDriverLocation C Program Files Emulex AutoPilot Installer Drivers Storport x86 Relative path example for x64 driver LocalDriverLocation Drivers Storport x64 Deleting Questions in the APinstall cfg File A STORPORT CONFIGURATION section may exist in the APInstall cfg file If this section does exist it may contain a QUESTIONS section with vendor specific installation questions You must remove the entire STORPORT CONFIGURATION section or comment it out for a silent installation Optional Configuration File Changes Locate the Optional Configuration File Changes heading in the AUTOPILOT CONFIG section of the APInstall cfg file This heading follows Mandatory Configuration File Changes Changing Utility Installation Location AutoPilot Installer normally installs utilities from a Utilities subdirectory located in the same directory as AutoPilot Installer To modify the location locate the following in the APInstall cfg file all in one line UtilitiesLocation C Program Files Emulex Autopilot Installer Windows Utilities Remove the semicolon before this line and modify this directory path to specify an alternate location such as a network shared drive Setting Up an Automatic System Restart During
12. z x Diagnostics Sv The Sel below shows the reat of Asc io Incl alen s dagnoses i When you hire firethed wenno the dagnesbe rants cekk Nest Tolen ihe dagrostes check fann Diagnostics Failure WS Assets Location JO Dever oF LE dO v00m sRPE Decet Paret Paned Orire A LPIOOID SHR SIPCLEU 3 Oerce 6 Fros Venn Uia Orie v LPUODND SRA IPCIGus 3 Device 7 Pased Paned User Dire ferda eoat an onu of UM PSOE DISABLED Ice thes HEA The cupaeited orion it The HEA wat harust dratied n the Device Mansour reenable the HEA Benn Cox Conc Figure 2 AutoPilot Installer Diagnostics window Perform the suggested corrective action and run APInstaller exe again Software First Installation The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive To perform a software first installation 1 If you have already extracted the driver and utility files run the APInstaller exe file If you have not extracted the driver and utility files run the distribution executable file see page 5 and leave the Start AutoPilot Installer box selected Click Finish The following message appears DE AutoPilot Installer Warning xj AutoPilot Installer cannot find any Emulex Fibre Channel HBAs in this system AutoPilot Installer can perform a driver pre installation allowing you to install your HBAs later Click OK to pre instal drivers or click Cancel
13. 0 0326 rurnrrvvrvrrrrrrrrrrrrrrrrrrrrrrrrrrrrnnsrrereenr 31 INIT Log Messages 0400 0463 rrnnnnnnnnnnnvnnvnvnnnnnnnnnnrrrrrrrrrrrrrrrrrrrrereenr 31 FCP Log Messages 0701 0749 arrrnnnnnnnnnnnnnnrrrnnnnnnnnrnnnnrrrrnnnennnrnnnnnrrnnnne 33 Link Log Messages 1302 1306 rrrnnnnnnnnnnnvvnnnnrrrrrrrrrrrrrrrrrrrrrrrsernnnnnn 35 Tag Messages 1400 1401 ceeeee cece eee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeas 36 NPIV Messages 1800 1899 aaa 36 ELS Messages 1900 1999 eceeeccceeeeeeeeeeeeeeeceeeeeeeeeeeeeeecaeeeeeeeeseaaaes 37 Error ao EE ER ee 37 Viewing the Error Log rnnnnnnnnnnnnnnnnnnnnrrrrrrrrrrrrrrrnrrnnnnnnnnnnnnnnnnnnnnnnnrrrrnnnn 37 Severity Scheme rnnnnnnnnnnnnnnnnnnrrnnnnnnnannnnnnrrnnnnnnnnnnnnnnnrrnnnnenssnnnnnnnrrnnnnnesenn 38 Related Driver Parameter LOQError ccccccecccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteees 38 Format of an Error Log Entry serere 39 Storport Miniport Driver User Manual Page iv X EMULEX Installation Introduction AutoPilot Installer for Emulex Storport Miniport drivers provides installation options that range from a simple installation with a few mouse clicks to custom unattended installations that use predefined script files AutoPilot Installer is included with Emulex drivers and utilities in Windows executable files that you can download from the Emulex Web site Run the distribution executable file to extract all of the software needed for an
14. 0x77 Mailbox context allocation failure Storport Miniport Driver User Manual Page 40 XEMULEX Table 6 Severe Errors Continued Bits 0 7 Interpretation Ox7A ELS receive LOGO context allocation failure 0x7D Mailbox context allocation failure Ox7E Mailbox context allocation failure Ox7F Mailbox context allocation failure 0x80 Mailbox context allocation failure 0x81 Mailbox context allocation failure 0x84 ELS FDISC context allocation failure 0x85 Mailbox context allocation failure 0x88 ELS PLOGI command context allocation failure 0x89 TELS RSCN registration command context allocation failure OxAO Port object construction failed OxA4 Unsupported command type command type in bits 8 31 OxCO Failed to allocate un cached extension OxC1 Port initialization failure OxC2 Utility mailbox command timeout OxC3 Fatal over temperature condition OxC4 Over temperature warning condition OxC5 Over temperature warning condition alleviated OxC6 Invalid response IOCB OxC7 Initialization failed due to exceeding max driver instances 256 OxC8 Initialization failed due to STORPORT SYS revision level too low OxXEC Failed to allocate authentication context Table 7 Malfunction Errors Bits 0 7 Interpretation 0x0C Set variable failed 0x26 Spurious mailbox attention 0x31 Unrecognized mailbox co
15. Contact Emulex Technical Support NPIV Messages 1800 1899 Ipfc mes1800 1800 NPIV FDISC failure VPI x x Error x x Reason x x DESCRIPTION Virtual Port fails on a FDISC to the switch with the error and reason listed SEVERITY Error LOG LOG_NPIV verbose ACTION Check to ensure the switch supports NPIV Ipfc_mes1801 1801 Memory allocation failure for NPIV port x x DESCRIPTION Fails to allocated the block of memory for the Virtual Port SEVERITY Error LOG LOG_NPIV verbose ACTION Check to ensure system has sufficient kernel memory Ipfc_mes1802 1802 Exceeded the MAX NPIV port x x DESCRIPTION Exceeded the number of Virtual Port allows on the HBA SEVERITY Error LOG LOG_NPIV verbose ACTION Reduce the number of Virtual Ports Ipfc_mes1803 1803 Virtual Port x x VPI x x successfully created DESCRIPTION Virtual Port ID is successfully created SEVERITY Information LOG LOG_NPIV verbose ACTION None required lpfc mes1804 1804 Removing Virtual Port x x VPI x x DESCRIPTION Removing Virtual Port ID SEVERITY Information LOG LOG_NPIV verbose ACTION None required Storport Miniport Driver User Manual Page 36 XEMULEX ELS Messages 1900 1999 1900 x x sends ELS AUTH CMD x x with TID x x DESCRIPTION An ELS AUTH CMD is sent SEVERITY Information LOG LOG FCSP verbose ACTION No action needed informational 1901 x x sends ELS AUTH REJECT x x x x to x x DESCRIPTION An ELS AUTH REJEGCT is
16. HBAs can manage those HBAs The Emulex driver and the HBAnyware utilities must be installed before you can install the HBAnyware Security Configurator To install the HBAnyware Security Configurator 1 Locate the SSCsetup exe file The default path for this file is C Program Files HBAnyware Double click the SSCsetup exe file A welcome window appears Click Next The Setup Status window is displayed After setup completes the Emulex HBAnyware Security Setup Completed window appears 4 Click Finish Installing the HBAnyware Utility Web Launch Feature In addition to the driver and HBAnyware utilities the following must be installed before you can install the Web Launch feature e Microsoft Internet Information Services IIS Server is installed See the Microsoft Web site for information on downloads and installation e Java Runtime Environment JRE is installed See the www java com Web site for information on downloads and installation To install the HBAnyware Utility Web launch feature Click Programs gt Emulex gt HBAnyware WebLaunch Install Web Launch installation begins Storport Miniport Driver User Manual Page 10 X EMULEX Updating the HBAnyware Utility Web Launch URL The driver HBAnyware utilities and HBAnyware Web Launch must be installed before you can update the URL To change the IP address for HBAnyware Web Launch 1 Copy WebLaunch related files to a sub directory called WebLaunch in the HBAnyware
17. Installation continues Select a management mode See Figure 1 for three types of host HBA management Storport Miniport Driver User Manual Page 7 X EMULEX 5 To prevent the management mode from being changed after installation clear the Allow users to change management mode after installing the utility check box BE AutoPilot Installer v7 3 1 7 EI Utilities Installation AatoP ol nitaller is prepanng lo risial managemert Villas on this host Select management type and check Net FK A C Strictly Local Management The utility only manages the HBAs on the host No remote management of HBAs is alowed C Local Management Phat The utility only manages the HBAs on thes host Management of HBAs on this host from other hosts is slowed Full Management The utiity manages the HBAs on thes host and other hosts that allow Managemert of HBAs om this host from other hosts amp allowed F Allow users to change management mode alter installing the utility Figure 1 AutoPilot Installer Management Mode Setup Note The display of the AutoPilot Installer Setup window is optional and based on settings in the APInstall cfg file See Setting Up Management Mode for Attended and Unattended Installations on page 15 for more information 6 Click Next Installation automatically completes except in the following situations If you are changing driver types the Available Drivers window appears This window allows yo
18. Pilot Installer Features Command line functionality Invokes AutoPilot Installer from the command line using customized installation scripts e Driver and utility updates Installs and updates drivers and utilities e Multiple HBA installation capability Installs drivers on multiple HBAs alleviates the need to manually install the same driver on all HBAs in the system e Driver diagnostics Determines whether the driver is properly operating e Silent installation mode Suppresses all screen output necessary for unattended installation e Management Mode Setup Parameters in the APInstall cfg file determine if you can manage HBAs remotely local and others and if you change the remote management options once the utility is installed Note See Setting Up Management Mode for Attended and Unattended Installations on page 15 in the Unattended Installation topic for more information Management mode parameters govern both attended and unattended installations Configuration Questions Vendor specific versions of the Emulex driver installation program may include one or more windows with questions that you must answer before continuing the installation process Storport Miniport Driver User Manual Page 6 Installation Planning X EMULEX Table 2 describes the types of installations that you can perform under certain conditions Use this information to determine which method to use for your situation Table 2 Type
19. Storport x64 for the x64 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport lA64 for the Itanium 64 bit driver version Click OK 8 Select Emulex PLUS Click Next and click Next again to install the driver 9 Click Finish The initial ElxPlus driver installation is complete Continue with manual installation of the Storport Miniport Driver See page 21 for this procedure Storport Miniport Driver User Manual Page 20 X EMULEX Manually Updating the Emulex PLUS ElxPlus Driver The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive Note Only one instance of the Emulex PLUS driver should be installed even if you have multiple HBAs or HBA ports installed in your system To update an existing ElxPlus driver from the desktop 1 Select Start gt Administrative Tools gt Computer Management 2 Click Device Manager left pane 3 Click the plus sign next to the Emulex PLUS class right pane to show the ElxPlus driver entry Right click the ElxPlus driver entry and select Update Driver from the menu Select No not this time Click Next on the Welcome to the Hardware Update Wizard window Click Next 6 Select Install from a list or specific location Advanced Click Next Select Don t Search will choose the driver to install 8 Click Have Disk Direct the Device Wizard
20. X EMULEX Storport Miniport Driver Version 2 00 for Windows Server 2003 Windows Vista User Manual Last updated November 29 2007 X EMULEX Copyright 2007 Emulex Corporation All rights reserved worldwide No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex Corporation Information furnished by Emulex Corporation is believed to be accurate and reliable However no responsibility is assumed by Emulex Corporation for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of Emulex Corporation Emulex AutoPilot Installer BlockGuard cLAN FabricStream FibreSpy Giganet HBAnyware InSpeed IntraLink LightPulse MultiPulse SAN Insite SBOD and Vixel are registered trademarks and AutoPilot Manager EZPilot SLI and VMPilot are trademarks of Emulex Corporation All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose Emulex Corporation may make improvements and changes to the product described in this manual at any time and without any
21. an Unattended Installation AutoPilot Installer does not automatically perform system restarts for the following reasons e Restarts often require a login as part of Windows start up process If the system is restarted the installation process stops until a login is performed e AutoPilot Installer does not know if it is safe to restart the system Restarts while applications are active can result in the loss of data To configure Windows to start up without requiring a login remove the semicolon from this line SilentRebootEnable FALSE Change this parameter to true SilentRebootEnable TRUE Storport Miniport Driver User Manual Page 13 X EMULEX Setting Up Installation Report Title and Location You can change the Installation report name and the location to which it is written This information must be specified in one command In the following example x is the system drive Remove the semicolon before ReportLocation x autopilot reports installs October16 06 txt Default File Name This default file name format is report_mm dd yy txt and uses mm for the month dd for the date and yy for the year Default Report Location By default the report is written to the system drive In the following example x is the system drive Your system drive may be different You can modify this line to change the report location and or file name ReportLocation x autopilot reports installs Octob
22. driver must be installed before you can manually install the driver utilities The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive If you have downloaded the Storport Miniport files to the default directory the path will be C Program Files Emulex AutoPilot Installer Utilities To install the utility 1 Run setup exe 2 Follow the instructions on the setup windows 3 Click Finish in the last console window to exit setup The utility installation has completed The HBAnyware utility automatically starts running Uninstalling the Utility Package To uninstall the HBAnyware utility and HBAnyware Web Launch if it is installed 1 Select Start gt Settings gt Control Panel The Add Remove Programs window appears Select the Install Uninstall tab 2 Select the Emulex Fibre Channel item and click Change Remove Click Next The utilities are removed from the system 3 Click Finish Uninstallation is complete Storport Miniport Driver User Manual Page 22 XEMULEX Uninstalling HBAnyware Web Launch To uninstall HBAnyware Web Launch but leave the HBAnyware utility installed 1 Select Start gt Programs gt Emulex gt HBAnyware WebLaunch Uninstall The following dialog screen appears 56 HBAnyware WebLaunch Uninstall ATT EMULEX HBANYVARE WEBLAUNCH UNINSTALLAT ION EE I I IGG DD Uninstalling VebLaunchSrv service DONE Deleting hbanyware jnlp f
23. driver registry settings 1 Browse to the Storport Miniport driver version 1 20 or later driver kit that you downloaded and extracted 2 Double click on the deladjct reg file A Registry Editor window appears to confirm that you want to execute deladjct reg 3 Click Yes The elxadjct key is removed from the registry Storport Miniport Driver User Manual Page 23 S EMULEX Configuration Introduction The Emulex Storport Miniport driver has many options that you can modify to provide for different behavior You can set Storport Miniport driver parameters using the HBAnyware configuration utility See the HBAnyware User Manual for more information Server Performance I O Coalescing I O Coalescing is enabled and controlled by two driver parameters CoalesceMsCnt and CoalesceRspCnt The effect of I O Coalescing will depend on the CPU resources available on the server With I O Coalescing turned on interrupts are batched reducing the number of interrupts and maximizing the number of commands processed with each interrupt For heavily loaded systems this will provide better throughput With I O Coalescing turned off the default each I O processes immediately one CPU interrupt per I O For systems not heavily loaded the default will provide better throughput The following table shows recommendations based upon the number of I Os per HBA Table 4 Recommended Settings for I O Coalescing Vos per Second a
24. e driver received a nameserver response containing a status error SEVERITY Error LOG LOG_DISCOVERY verbose ACTION Check Fabric configuration The driver recovers from this and continues with device discovery SEE ALSO Ipfc_mes0236 Storport Miniport Driver User Manual Page 30 X EMULEX lpfc_mes0256 0256 Start node timer on NPortld x x timeout value d DESCRIPTION Starting timer for disconnected target with NPort ID and timeout value SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0260 0260 Stop node timer on NPortld x x SCSIId x x DESCRIPTION Discontinuing timer for reconnected target with NPort ID and SCSI ID SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0262 0262 Node timeout on NPortld x x SCSIId x x DESCRIPTION Disconnected NPort ID SCSI ID has failed to reconnect within timeout limit SEVERITY Error LOG LOG_ELS verbose ACTION Review system configuration Mailbox Log Messages 0310 0326 lpfc mes0310 0310 Mailbox command timeout HBA unresponsive DESCRIPTION A Mailbox command was posted to the adapter and did not complete within 30 seconds sync 0 asynchronous mailbox command is issued 1 synchronous mailbox command is issued SEVERITY Error LOG LOG MBOX verbose ACTION This error could indicate a software driver or firmware problem If no I O is going through the adapter reboot the sys
25. emoving the Adjunct Driver Registry Key The ElxPlus driver replaces the adjunct driver that was used with Storport Miniport 11 a3 or earlier If currently installed the adjunct driver registry key must be removed using the deladjct reg file before you install the ElxPlus driver The deladjct reg file was extracted when you ran the Distribution Executable File Manually Installing the Emulex PLUS ElxPlus Driver for the First Time The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive Note Only one instance of the Emulex PLUS driver should be installed even if you have multiple HBAs or HBA ports installed in your system To install the ElxPlus driver from the desktop 1 Select Start gt Control Panel gt Add Hardware The Add Hardware Wizard window appears Click Next Select Yes have already connected the hardware Click Next Select Add a new hardware device Click Next Select Install the hardware that manually select from a list Advanced Click Next Select Show All Devices Click Next Click Have Disk Direct the Device Wizard to the location of elxplus inf If you have downloaded the Storport Miniport files to the default directory the path will be le a a C Program Files Emulex AutoPilot Installer Drivers Storport x86 for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers
26. en I Os lt 10000 0 8 10000 lt I Os lt 18000 1 8 18000 lt I Os lt 26000 1 16 l Os gt 26000 1 24 CoalesceMsCnt The CoalesceMsCnt parameter controls the maximum elapsed time in milliseconds that the HBA waits before it generates a CPU interrupt The value range is 0 63 decimal or 0x0 Ox3F hex The default is 0 and disables I O Coalescing CoalesceRspCnt The CoalesceRspCnt parameter controls the maximum number of responses to batch before an interrupt generates If CoalesceRspCnt expires an interrupt generates for all responses collected up to that point With CoalesceRspCnt set to less than 2 response coalescing is disabled and an interrupt triggers for each response The value range for CoalesceRspCnt is 1 255 decimal or 0x1 OxFF hex The default value is 8 Note A system restart is required to make changes to CoalesceMsCnt and or CoalesceRspCnt Storport Miniport Driver User Manual Page 24 X EMULEX Performance Testing There are four driver parameters that need to be considered and perhaps changed from the default for better performance testing QueueDepth NumFcpContext CoalesceMsCnt and CoalesceRspCnt Note Parameter values recommended in this topic are for performance testing only and not for general operation QueueDepth If the number of outstanding I Os per device is expected to exceed 32 increase this parameter to a value greater than the number of expected I Os pe
27. erl6 06 txt Note Both the report location and file name must be specified Setting Up an Installation Without Utilities You can set up the unattended installation to install the driver without installing the utilities package The default for this setting is false which means that the utilities are automatically installed with an unattended installation To set up an installation without utilities remove the semicolon before SkipUtilityInstall FALSE Change this parameter to true SkipUtilityInstall TRUE Preventing Software First Installations AutoPilot Installer defaults to automatically installing the driver whether or not any HBAs are discovered Setting this parameter to true allows AutoPilot Installer to run on every server in your SAN but only update the ones that actually have HBAs To prevent software first installations remove the semicolon before NoSoftwareFirstInstalls False Change this parameter to true NoSoftwareFirstInstalls TRUE Setting Up Existing Driver Parameters Retention or Override The ForceRegUpdate driver parameter setting determines if existing driver parameters are retained or changed when you update the driver This parameter defaults to false and means all existing driver parameter settings are retained Setting the ForceRegUpdate parameter to true causes removal of all existing driver parameters from the registry and replaces them with the parameters specified i
28. est to bring the adapter offline This may occur when running HBAnyware SEVERITY Warning LOG LOG INIT verbose ACTION None required lpfc_mes0463 0463 Adapter firmware error hostStatus x x Info1 OxA8 x x Info2 OxAC X X DESCRIPTION The firmware has interrupted the host with a firmware trap error SEVERITY Error LOG LOG_INIT verbose ACTION Review HBAnyware diagnostic dump information FCP Log Messages 0701 0749 lpfc_mes0701 0701 Issue Abort Task Set to Pathld x x Targetld x x Lun x x DESCRIPTION The driver has issued a task management command for the indicated SCSI device address SEVERITY Warning LOG LOG_INIT verbose ACTION Review system configuration lpfc_mes0703 0703 Issue LUN reset to Pathld x x Targetld x x Lun x x Did x x DESCRIPTION Storport is requesting a reset of the indicated LUN SEVERITY Warning LOG LOG_INIT verbose ACTION Review system configuration Possible side effect of cluster operations Ipfc mes0713 0713 Issued Target Reset to Pathld d Targetld d Did x x DESCRIPTION Storport detected that it needs to abort all I O to a specific target This results in login reset to the target in question SEVERITY Warning LOG LOG FCP verbose ACTION Review system configuration Possible side effect of cluster operations SEE ALSO Ipfc mes0714 lpfc mes0714 0714 Issued Bus Reset for Pathld d DESCRIPTION Storport is requesting the driver to reset al
29. g the Storport Miniport Driver 21 Manually Installing the Driver Utilities rarrrrrrrnrrrrrrvrnrrrvrrvvrrvrrnrnnnnrrsrererenr 22 Uninstalling the Utility Package rrrrnnnnnnnnnnnnnnvnvnrvnrrvrrrrrrererrerererrrrrrerererrrreee 22 Uninstalling HBAnyware Web Launch rrrnnnnnrrnnnnvvrvvrrvvrrvvnvnvnvrrrrnrnnnnnrsrsrerenr 23 Uninstalling the Emulex DNvVErS sesarcrcsrsansisisis iina 23 Gontiguration u vur mmene mu bankene de a ea 24 Introduction cece eeeeeeeeeeeeeeaaeeeeeeeeeeeeeaaaaaeaeeeeeeeesaaaaaaeeeeeeeeseaaaaadeeeeeeeesaaaaeees 24 Storport Miniport Driver User Manual Page iii 9 Table of Contents gt gt EMULEX Server Performance rrnnnnnnnnnnnnnnrrnnnnnnnnnnnnnnnrnnnnnnnnnnnnnnnrrnnnenssnennnnnrrnnneessnnnnnnnrrnnene 24 1 0 Ode ETL oa 0 000 ee cece eeeeteteee cece eee eeecceee tees eee tteeeeeee sete eet edecaaaeeeeeeeeegeecaaeeeseneeeaaea 24 Performance Testing ccecceceeeeceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeas 25 Troubleshooting esee a 26 INtPOCUCTION nn nn nnn nn ANNANN 26 Event Tracing Windows Server 2003 SP1 and later only iseenesesse 26 Event Trace Messages mmmmnnnnnnnnnnnnnnnnnnnnnnnnrsnnnnnnnnnnnnnnnnnnnnnnnnnnenennnnenenenennnnnnnn 27 ELS Log Messages 0100 0130 rrrrrnnnnnnnnnnnnnrrrnnnnnnnnrnnnnnrrrnnnennerrrrrnnnne 27 Discovery Log Messages 0202 0262 unnnnnnnnnnnnnnnnnnnnnrnrrrrrrrrrrrrrrrrrrerrenn 29 Mailbox Log Messages 031
30. hanged to true AutoPilot Installer will cause silent installations to update or install the current driver on each HBA in the system without any regard to the current driver type For example you would want this option left on or set to true to silently install the Storport Miniport driver on any HBAs currently running SCSlport Miniport or FC Port drivers Remove the semicolon from this line ForceDriverTypeChange FALSE Change this parameter to true ForceDriverTypeChange TRUE Setting Up Management Mode for Attended and Unattended Installations There are three parameters that control management mode ManagementMode ManagmentModeChangable and HideManagementModeGUI ManagementMode Full the utility manages the HBAs on this host and other hosts that allow it Management of HBAs on this host from other hosts is also allowed LocalOnly the utility manages only the HBA on this host and no remote management of HBAs is allowed e LocalPlus The utility manages only the HBAs on this host however management of HBAs on this host from other hosts is allowed Storport Miniport Driver User Manual Page 15 S EMULEX To change this parameter Remove the semicolon from this line ManagementMode FULL Change this parameter value Example ManagementMode LOCALONLY ManagementModeChangable True allows you to change the ManagementMode from the HBAnyware Utility Management Mode window If this parameter is
31. ified or confirmed and may apply to another product such as hardware No known issues at this time New in This Release e Supports FC Security Protocol Diffie Hellman Challenge Handshake Authentication Protocol FC SP DHCHAP e Supports dynamic LUN masking with the HBAnyware utility e Supports Microsoft System Center Virtual Machine Manager for Microsoft Virtual Server Storport Miniport Driver User Manual Page 3 X EMULEX Files Included in this AutoPilot Installer The Distribution File copies the AutoPilot Installer Files to your system By default these files are copied to c Program Files Emulex AutoPilot Installer Table 1 AutoPilot Installer Files Folder Description AutoPilot Installer This folder contains files necessary to run the AutoPilot Installer APInstall exe Executable file for the AutoPilot Installer e APInstall cfg Configuration file for the AutoPilot Installer FriendlyName exe Provides display names for installed HBAs Apinstaller 1A64 Folder Apinstaller x64 Folder Apinstaller x86 Folder These folders contain files necessary to run the AutoPilot Installer e APinstall exe Executable file for the AutoPilot Installer e APInstall cfg Configuration file for the AutoPilot Installer e SilentApinstalllExampleText txt Information and example script for silent installations Drivers Folder This folder contains the Storport Miniport folder and files necessar
32. ile DONE Deleting HBAnyware WebLaunch directory DONE Uninstallation conplete Press any key to continue Figure 5 HBAnyware Web Launch Uninstallation dialog screen 2 HBAnyware Web Launch is removed Press any key to continue Uninstalling the Emulex Drivers The Emulex Storport Miniport and PLUS ElxPlus drivers are uninstalled using the Device Manager The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive To uninstall the Emulex Storport Miniport driver Select Start gt All Programs gt Administrative Tools gt Computer Management 2 Click Device Manager 3 Double click the HBA from which you want to remove the Storport Miniport driver A device specific console window is displayed Select the Driver tab 4 Click Uninstall and click OK to uninstall To uninstall the ElxPlus driver uninstall the ElxPlus driver only if all HBAs and installations of Emulex miniport drivers are uninstalled After running Device Manager steps 1 and 2 above 1 Click the plus sign next to the Emulex PLUS driver class 2 Right click the Emulex driver and click Uninstall 3 Click OK in the Confirm Device Removal Window To uninstall or update an earlier version of the Storport Miniport driver prior to version 1 20 you must remove the registry settings for the adjunct driver prior to manually installing a new driver To remove the adjunct
33. installation then complete the installation using AutoPilot Installer AutoPilot Installer allows you to install a driver by any of the following methods Hardware first installation The host bus adapter HBA has already been installed before you download the Emulex drivers and utilities Software first installation This installation method allows you to download drivers and utilities from the Emulex Web site and to install them using AutoPilot Installer prior to the installation of any HBAs You do not need to specify the model of the HBA you plan to install The appropriate drivers and utilities automatically load when you install HBAs at a later time Unattended installation This installation method allows you to set up AutoPilot Installer to run unattended from customized scripts Unattended installation works for both hardware first and software first installations An unattended installation e Enables you to set up one location that contains the distribution executable file All of the servers install or update the driver and utilities from that location e Operates from the command line e Operates in silent mode e Creates an extensive report file Reports any errors Replicated installation This installation method allows you to preload drivers and utilities on a system Possible applications include installing a driver and utilities in advance on a system before adding HBAs and performing system installations that execute
34. installation directory 2 Click on Programs gt Emulex gt HBAnyware WebLaunch Update URL 3 Type the URL address that you want HBAnyware Web Launch to use 54 HBAnyware WebLaunch Update URL 00 ee ee ee ee ee ee ee EE OE EE OM MMMM MMM MMMM MMMM MM i Mm EMULEX HBANYWARE WEBLAUNCH JNLP UPDATE ELLER EEE EEE EEE Emulex HBAanyware WebLaunch has found the following IP address 138 239 87 66 Do you want to configure this IP address for HBAnyware WebLaunch Type y yes to use this IP address or Type n no to provide your own IP address or Type q to quit configuring IP address User input Figure 4 HBAnyware Web Launch Update URL dialog screen Unattended Installation To invoke an unattended installation the Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive Unattended installation is invoked from the command line The apinstall command uses installation and driver settings stored ina configuration file APInstall cfg The default APInstall cfg file is located in the AutoPilot Installer folder in the Emulex folder in the Program Files directory Make a copy of the APInstall cfg file before you make modifications The APInstall cfg file should be used as a starting point for scripting an unattended installation Mandatory configuration file changes e Enabling silent mode e Setting up allowable driver types e Setting up driver locations Optiona
35. ion file In the following example the configuration file has been renamed and relocated Example ApInstall g autopilot mysetup cs apinstall cfg Batch File Example Modifying the configuration file enables you to script the installation of a system s driver The following example batch file assumes that you have made mandatory changes to the APInstall cfg file as well as any desired optional changes If your systems have been set up with a service that supports remote execution then you can create a batch file to remotely update drivers for all of the systems on the storage net If Microsoft s RCMD service was installed for example a batch file similar to the following would run remote execution remd serverl g autopilot ApInstall g autopilot mysetup apinstall cfg if errorlevel 1 goto serverlok echo AutoPilot reported an error upgrading Server 1 if not errorlevel 2147483650 goto unsupported echo Configuration file missing goto serverlok unsupported if not errorlevel 2147483649 goto older echo Unsupported operating system detected older if not errorlevel 2001 goto none echo The driver found is the same or older than the existing driver goto serverlok none if not errorlevel 1248 goto noreport echo No HBA found goto serverlok noreport if not errorlevel 110 goto nocfg echo Could not open installation report file goto serverlok Storport Miniport Driver User Manual Page 18 XEMULEX nocfg if not errorlevel 87
36. is error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support lpfc mes0442 0442 Adapter failed to init CONFIG PORT mbxStatus x x DESCRIPTION Adapter initialization failed when issuing CONFIG_PORT mailbox command SEVERITY Error LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support lpfc_mes0446 0446 Adapter failed to init CONFIG RING mbxStatus x x DESCRIPTION Adapter initialization failed when issuing CFG_RING mailbox command SEVERITY LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support lpfc_mes0454 0454 Adapter failed to init INIT LINK mbxStatus x x DESCRIPTION Adapter initialization failed when issuing INIT_LINK mailbox command SEVERITY Error LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc mes0458 0458 Bring Adapter online DESCRIPTION The FC driver has received a request to bring the adapter online This may occur when running HBAnyware SEVERITY Warning LOG LOG_INIT verbose ACTION None required Storport Miniport Driver User Manual Page 32 S EMULEX lpfc_mes0460 0460 Bring Adapter offline DESCRIPTION The FC driver has received a requ
37. l configuration file changes e Changing the utility installation location e Setting up an automatic system restart during an unattended Installation e Setting up the installation report title and location e Setting up an installation without utilities e Preventing software first installations e Setting up the existing driver parameter values to be retained or overwritten Storport Miniport Driver User Manual Page 11 X EMULEX e Setting up the re installation of an existing driver version e Setting up management mode for attended and unattended installation e Setting up re installation of an existing driver version AutoPilot Configuration File Format The APInstall cfg file is organized into commented sections grouped according to related commands e Lines that begin with a semicolon are comments To enable sample comment lines remove the semicolon There are five main sections Three are required and two are optional Driver parameters must be set up in the STORPORT PARAMS section Each section begins with a heading e AUTOPILOT ID This required section contains revision and label information e AUTOPILOT CONFIG This required section contains settings that control and configure the AutoPilot Installer s operation e STORPORT CONFIGURATION This optional section may contain questions that must be answered during the installation process This section applies to attended installations only STORPORT PARAMS This
38. l targets on this HBA SEVERITY Warning LOG LOG FCP verbose ACTION Review system configuration Possible side effect of cluster operations SEE ALSO Ipfc_mes0713 Storport Miniport Driver User Manual Page 33 X EMULEX lofc_mes0716 0716 FCP Read Underrun expected d residual d DESCRIPTION FCP device provided less data than was requested SEVERITY Supplement Information LOG LOG_FCP verbose ACTION No action needed informational SEE ALSO lpfc_mes0730 lpfc_mes0729 0729 FCP command error ulpStatus x x ulpWord 4 x x XRI x x ulpWord 7 x x DESCRIPTION The specified device failed an I O FCP command SEVERITY Warning LOG LOG FCP verbose ACTION Check the state of the target in question REMARKS Ipfc mes0730 is also recorded if it is a FCP Rsp error Ipfc mes0730 0730 FCP response error Flags x x SCSI status x x Residual d DESCRIPTION The FCP command failed with a response error SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question remark Ipfc mes0716 lpfc_mes0734 Ipfc mes0736 or lpfc_mes0737 is also recorded for more details if the corresponding SEVERITY level is set SEE ALSO Ipfc_mes0729 Ipfc mes0734 0734 Read Check fcp_parm x x Residual x x DESCRIPTION The issued FCP command returned a Read Check Error SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question SEE ALSO Ipfc_mes0730 lpfc_mes0737
39. ly User chose to stop installation because a recommended QFE or Service Pack was not installed 2399141899 0x8F00000B Silent mode installation did not find any drivers of the type specified in the config file 2399141900 0x8F00000C A silent reboot was attempted but according to the operating system a reboot is not possible 2399141901 0x8F00000D GUI Mode only A driver package download was cancelled 2399141902 0x8F00000E Non Enterprise No HBAs were found in the system Note To stop this error and perform a software first installation be sure that the line enableEnterpriseMode True is in the configuration file 2399141903 0x8F00000F A required QFE or Service Pack was not detected on the system 2399141836 0x8F000030 AutoPilot Installer was not invoked from an account with Administrator level privileges 2399141952 0x8F000040 AutoPilot Installer has detected unsupported HBAs on the system Storport Miniport Driver User Manual Page 17 X EMULEX Invoking AutoPilot Installer If the configuration file has been modified and saved with its original name APInstall cfg and you want to invoke the AutoPilot Installer at the command line type apinstall If the configuration file has been modified and saved with a different name and or the configuration file location has changed you must specify the entire path location using the standard drive directory path filename format and the entire name of the configurat
40. mes0112 lpfc mes0115 0115 Unknown ELS command x x received from NPortld x x n DESCRIPTION Received an unsupported ELS command from a remote NPORT SEVERITY Error LOG LOG_ELS verbose ACTION Check remote NPORT for potential problem SEE ALSO Ipfc_mes0112 lpfc mes0128 0128 Accepted ELS command OpCode x x DESCRIPTION Accepted ELS command from a remote NPORT SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0129 0129 Rejected ELS command OpCode x x DESCRIPTION Rejected ELS command from a remote NPORT SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc mes0130 0130 ELS command error ulpStatus x x ulpWord 4 x x DESCRIPTION ELS command failure SEVERITY Error LOG LOG_ELS verbose ACTION Check remote NPORT for potential problem Storport Miniport Driver User Manual Page 28 X EMULEX Discovery Log Messages 0202 0262 Ipfc mes0202 0202 Start Discovery Link Down Timeout x x initial PLOGICount d DESCRIPTION Device discovery rediscovery after FLOGI FAN or RSCN has started TMO is the current value of the soft link time It is used for link discovery against the LinkDownTime set in parameters DISC CNT is number of nodes being discovered for link discovery RSCN CNT is number of nodes being discovered for RSCN discovery There will be value in either DISC CNT or RSCN CNT depending which discovery is being pe
41. mpletion command code 0x33 TfInvalidlinkstte S 0x36 Initialization command failed status in bits 8 31 0x3B Discovery error due to lack of resources insufficient RPIs Ox3E Unable to create discovered node object Ox3F Failed to issue ELS process login PRLI command 0x45 Retries exhausted to ELS FLOGI 0x47 Failed to issue UNREG_VPI 0x48 No exchange available for extended link service request ELS command 0x4C Exhaustedretrieson ELS PLOG O 0x53 WWPN mismatch on ADISC response 0x54 WWNN mismatch on ADISC response Storport Miniport Driver User Manual Page 41 Table 7 Malfunction Errors Continued XEMULEX Bits 0 7 Interpretation 0x55 Exhausted retries on ELS ADISC 0X59 Exhausted retries on ELS LOGO 0X5B Attempted ELS PRLI non existent node 0x5D Exhausted retries on ELS PRLI 0x63 Attempt to issue command to fabric without a valid fabric login 0x65 Error issuing fabric command status in bits 8 31 0x66 Invalid fabric command type Ox6A Invalid fabric command sub type Ox6C Name server response error status in bits 8 31 0x6D Name server response error status in bits 8 31 Ox6F SCN registration failed 0x71 Received unsupported ELS command type in bits 8 31 0x76 Invalid format for received PRLI 0x83 Node object allocation failure 0x9A SCSI command error SCSI status in bits 8 31 OxA2 Generalized command context allocation failure O
42. n the APInstall cfg file The ForceRegUpdate parameter does not affect any existing persistent bindings Storport Miniport Driver User Manual Page 14 X EMULEX To set up an installation to remove the existing driver parameters from the registry and replace them with parameters specified in the APInstall cfg file remove the semicolon before ForceRegUpdate FALSE Note You can also use this setting for attended installations with the AutoPilot Installer wizard if you modify the APInstall cfg file in the AutoPilot Installer folder Change this parameter to true ForceRegUpdate TRUE Setting Up Re Installation of an Existing Driver Version By default AutoPilot Installer will only update a driver if the new driver version is different from the installed driver version If necessary you can use the ForceDriverUpdate setting to re install the same driver version To force a re installation of the same driver type and version remove the semicolon from this line ForceDriverUpdate FALSE Change this parameter to true ForceDriverUpdate TRUE Note This setting can only be used for unattended installations Setting Up a Driver Type to Force By default the ForceDriverTypeChange parameter is set to false When set to false AutoPilot Installer will only install drivers on HBAs that have no other driver installed or whose current driver type matches that of the driver being installed If this parameter is c
43. nnnnrrrnnnnnnnrrnnnnrrrnnnnnnnnrrnnnrrrnnneesnnrrrnnnnn 1 AutoPilot Installer Terminates with Legacy HBAs Installed eects 2 Updating the Storport Miniport Driver Using AutoPilot Installer rrwrrrrrnnnrnrn 2 BEAT EE EE EE ere eee reer rere ere 2 Storport Miniport Driver Information eeavavrnnnnrrrrnnnnnnnrnnnnnrrnnnnnnnnrrnnnnrrrnnnnnessrrnnnnnn 3 KNOWN ISSUS AN 3 New im TMS JREICAS O eriin arrei aroa CE A E E AET CAA 3 Files Included in this AutoPilot Installer 0 0 cece rere eeeeeeeeeeteeeeetees 4 Distribution Executable File Overview rrrnnnnnnnnnnnnnrrrrnnnnnnnrnnnnnrrnnnnnnnnrrnnnnrrrnnnessnnnn 5 Running the Distribution Executable File eee eee cece eee eeeeeeeeeeeeeeeeeeeeeeeees 5 AutoPilot matale aa 6 Introd cion mrene E A E AR 6 AutoPilot Installer Features 00 0 0 i i iii 6 Configuration Questions rrnvrrnnnnnnnvrrnrrrnnnnnnnrnnnnnrrnnrrnnenennsrrnnnnnrrnnnsernnnnnn 6 Installation Planning sennie ARAARA 7 AutoPilot Installation Procedures sxcsinsssnsneseasnnnaraancsassnanasmensaansannsananntanannsshasmadbiadnedts 7 Hardware First Installation eeeccecrrrrrnnnnrnnrrnnnrrnnrvrrrrrrrrerrrrerrrrererrerrrrrrrerereren 7 If the Installation Fall Greses AAAA 9 Software First Installation eesooronnnnrrrrnnnnnnnnrrrrnnnnnnnnnnnnrnnnnnrrnnnnennnrrnnnnnnnennnnn 9 Installing the HBAnyware Security Configurator eurrrrrnornnnnrrrrnnnnnnnrnnnnrrrnnnnnnnenn 10 Installing the HBAnyware U
44. notice Emulex Corporation assumes no responsibility for its use nor for any infringements of patents or other rights of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex Corporation disclaims any undertaking to give notice of such changes DH CHAP Notice License Copyright c 1998 2006 The OpenSSL Project All rights reserved This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org SSLeay License Copyright C 1995 1998 Eric Young eay cryptsoft com All rights reserved This product includes cryptographic software written by Eric Young eay cryptsoft com This product includes software written by Tim Hudson tjh cryptsoft com Windows DH CHAP Notice Derived from the RSA Data Security Inc MD5 Message Digest Algorithm Copyright C 1991 2 RSA Data Security Inc Created 1991 All rights reserved Storport Miniport Driver User Manual Page ii 9 Table of Contents gt gt EMULEX MVS ea TNO ek Pees wats escent manners nana ets a nae es eee ea cea eee ote 1 Medellin ar 1 Important Considerations rnrrrrnnnnnnnnnnnnrrrnnnnnnnnnnnnnnrrnnnnnnnnrnnnnnrrnnnnensnrnnnnnrrrnnnnsenenn 1 Changing Driver Types rrrnnnnnnnnnnnnrnnnnnrrnnnnnrnnnnrrnnnnnnnnnrnnnennnnnrrnnnnnssnnnnnnnnnnennsen 1 Microsoft Storport Driver Update rrannvrn
45. omplete now off line 0x22 Port shutdown complete 0x23 Port re initialization complete now on line OxA5 Data under run residual in bits 8 31 0xDO NPIV Virtual Port creation success Virtual Port Did in bits 8 31 0xD1 NPIV Virtual Port creation failed Virtual Port Index inbits8 31 0xD2 NPIV Virtual Port FDISC failed Virtual Port index in bits 8 31 0xD3 NPIV Virtual Port memory allocation failed Virtual Port index in bits 8 31 0xD4 Exceeded maximum Virtual Port supported Virtual Port index in bits 8 31 0xD5 NPIV Virtual Port removal Virtual Port Did in bits 8 31 0xE0 Authenticated successfully remote Did in bits 8 31 0xE1 Failed to authenticate remote Did in bits 8 31 0xE2 Authentication not supported remote Did in bits 8 31 OxE3 Authenticated ELS command timeout remote Did in bits8 31 0xE4 Authentication transaction timeout remote Did in bits 8 31 0xE5 LS_RJT other than Logical Busy received for Authentication transaction remote Did in bits 8 31 OxE6 LS RJT Logical Busy received for Authentication transaction remote Did in bits 8 31 OxE7 Received Authentication Reject other than Restart remote Did in bits 8 31 OxE8 Received Authentication Reject Restart remote Did in bits 8 31 OxE9 Received Authentication Negotiate remote Did in bits 8 31 OxEA Authenticating spurious traffic remote Did in bits 8 31 OxEB Authentication policy has been changed remote Did in bits 8 31
46. ose ACTION No action needed informational SEE ALSO Ipfc_mes0110 lpfc_mes0103 0103 PRLI completes to NPortld x x TypeMask x x Fcp2Recovery x x DESCRIPTION The HBA performed a PRLI into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational SEE ALSO Ipfc_mes0110 Ipfc mes0104 0104 ADISC completes to NPortld x x DESCRIPTION The HBA performed an ADISC into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational SEE ALSO Ipfc mes0110 lpfc_mes0105 0105 LOGO completes to NPortld x x DESCRIPTION The HBA performed a LOGO into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 27 X EMULEX lofc_mes0112 0112 ELS command x x received from NPortld x x DESCRIPTION Received the specific ELS command from a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational REMARKS Ipfc_mes0114 and Ipfc mes0115 are also recorded for more details if the corresponding SEVERITY level is set You can use the XRI to match the messages lofc_mes0114 0114 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its FC service parameters match this HBA Request can be accepted SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational SEE ALSO Ipfc
47. r device up to a maximum of 254 The QueueDepth parameter defaults to 32 If 32 is set and not a high enough value performance degradation may occur due to Storport throttling its device queue NumFcpContext If the number of outstanding I Os per HBA is expected to exceed 512 increase this parameter to a value greater than the number of expected I Os per HBA Increase this value in stages from 128 to 256 to 512 to 1024 to a maximum of 2048i NumFcpContext limits the number of outstanding I Os per HBA regardless of how QueueDepth is set The NumFcpContext defaults to 512 If NumFcpContext is too small relative to the total number of outstanding I Os on all devices combined performance degradation may occur due to I O stream throttling CoalesceMsCnt CoalesceMsCnt defaults to zero If you are using a performance evaluation tool such as IOMETER and if you expect the I O activity will be greater than 8000 I Os per second set CoalesceMsCnt to 1 and re initialized with an HBA reset or system reboot CoalesceRspCnt CoalesceRspCnt defaults to 8 For all other values up to the maximum of 63 the HBA will not interrupt the host with a completion until either CoalesceMsCnt milliseconds has elapsed or CoalesceRspCnt responses are pending The value of these two driver parameters reduces the number of interrupts per second which improves overall CPU utilization However there is a point where the number of I Os per second is small relative to CoalesceM
48. rformed SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational lpfc_mes0204 0204 Discovered SCSI Target WWN word 0 x x WWN word 1 x x DID X X RPI x x DESCRIPTION Device discovery found SCSI target SEVERITY Information LOG LOG DISCOVERY verbose AGTION No action needed informational Ipfc mes0214 0214 RSCN received Word count d DESCRIPTION Received RSCN from fabric SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational lpfc_mes0215 0215 RSCN processed DID x x DESCRIPTION Processed RSCN from fabric SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc mes0225 0225 Device Discovery completes DESCRIPTION This indicates successful completion of device re discovery after a link up SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc mes0229 0229 Assign SCSIId x x to WWN word 0 x x WWN word 1 x x NPortld X X DESCRIPTION The driver assigned a SCSI ID to a discovered mapped FCP target BindType 0 DID 1 WWNN 2 WWPN SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 29 X EMULEX lpfc_mes0230 0230 Cannot assign SCSIId to WWN word 0 x x WWN word 1 x x NPortld X X DESCRIPTION SCSI ID assignment failed for discovered target SEVERITY
49. s of Installations Attended Installations Unattended Installations Condition Hardware First Installation Software First Installation Unattended Installation Replicated Installation No HBA in a single system X New HBA in a single system Existing HBAs and drivers installed updated driver available Multiple systems no HBAs installed Multiple systems new HBAs installed X AutoPilot Installation Procedures Hardware First Installation The Distribution Executable file must have been downloaded from the Emulex Web site and extracted to a directory on your local drive Note To update the Storport Miniport driver begin the following procedure at step 2 To perform a hardware first installation 1 Install a new Emulex HBA and power on the system If the Windows Found New Hardware wizard is displayed click Cancel to exit AutoPilot Installer performs this function Note If there are multiple HBAs in the system the Windows Found New Hardware wizard appears for each HBA Click Cancel to exit the wizard for each HBA 2 If you have already extracted the driver and utility files run the APInstaller exe file If you have not extracted the driver and utility files run the distribution executable file see Running the Distribution Executable File on page 5 and leave the Start AutoPilot Installer box selected Click Finish 3 Click Next
50. sCnt and this will slow down the completion process causing performance degradation Performance Testing Examples Test Scenario One You execute IOMETER with an I O depth of 1 I O per device in a small scale configuration 16 devices In this case the test does not exceed the HBA s performance limits and the number of I Os per second are in the low thousands Recommendation set CoalesceMsCnt to 0 or leave the default value Test Scenario Two You execute IOMETER with an I O depth of 48 per device in a small scale configuration 16 devices Recommendation set QueueDepth to be greater than 48 e g 64 and NumFcpContext to be greater than 512 e g 1024 Storport Miniport Driver User Manual Page 25 X EMULEX Troubleshooting Introduction There are several circumstances in which your system may operate in an unexpected manner The Troubleshooting section contains reference tables on event codes and error messages and provides information regarding unusual situations Event Tracing Windows Server 2003 SP1 and later only Trace messages are part of the Emulex Ipfc log messages Storage Event Tracing supports two types of events FFlInit 0x00000001 events that occurred at HwFindAdapter and Hwinitialize e FFlo 0x00000002 events that occurred during I O Storage Event Tracing supports four levels of events e DbgLvlErr 0x00000001 error level e DbGLvlWrn 0x00000002 warning level e DbgLvilnfo 0x00000004
51. set to false you must reinstall HBAnyware to change the management mode To change this parameter Remove the semicolon from this line ManagementModeChangable TRUE Change this parameter value to false ManagementModeChangable FALSE HideManagementModeGUI By default this parameter is set to false False allows the AutoPilot Installer Utility Installation window to be displayed during utility installation If this parameter is set to true AutoPilot Installer reads the APInstall cfg parameters and installs them accordingly without the option to change how management mode is setup To change this parameter Remove the semicolon from this line HideManagementModeGUI FALSE Change this parameter value to true HideManagementModeGUI TRUE Setting Up Driver Parameters To change driver parameter modify this section of the APInstall cfg file Locate the STORPORT PARAMS section in the APInstall cfg file This section follows Optional Configuration File Changes Under the STORPORT PARAMS heading list the parameters and new values for the driver to use For example Driver Parameter LinkTimeout 45 See the HBAnyware Utility User Manual for a listing of driver parameters and their defaults and valid values Setting Up System Parameters To change the system parameters create a SYSTEM PARAMS section in the APInstall cfg file Create this section in the Optional Configuration File Changes heading in
52. soft Storport driver Compatibility e The Emulex Storport Miniport driver is compatible with the following FC HBAs e LPe11002 LPe11000 and LPe1150 minimum firmware version 2 50a6 version 2 70a5 is required for SLI 3 functionality e LP11002 LP11000 and LP1150 minimum firmware version 2 10a10 version 2 70a5 is required for SLI 3 functionality Note To run the driver using NPIV or SLI 3 optimization the firmware must be version 2 72a0 or later If an earlier version is used the driver will run in SLI 2 mode and will not support NPIV e _LP10000ExDC and LP1050Ex minimum firmware version 1 90a4 e _LP10000DC and LP10000 minimum firmware version 190a4 e LP1005DC CM2 minimum firmware 1 90a5 e LP1050 and LP1050DC minimum firmware version 1 90a4 e LP9802DC LP9802 and LP982 minimum firmware version 1 90a4 e LP9402DC LP9002DC LP9002L LP9000 amp LP952L minimum firmware version 3 92a2 e LP8000 LP8000DC and LP850 e x86 BootBIOS minimum x86 BootBIOS version 1 70a3 EFIBoot Version 3 11a4 or higher 64 bit only e This version of the driver is compatible with version 3 3 of the HBAnyware utility This is the version of HBAnyware that is included in the distribution executable file Version 3 3 of the HBAnyware utility is not compatible with earlier versions of the Emulex Storport Miniport driver Known Issues The following issues have been reported at the time of publication These issues may not yet have been ver
53. stem All ELXSTOR error log entries are found under the System branch and all ELXSTOR error log entries have the Event Viewer severity level of error A severe error code indicates that the driver firmware or host bus adapter HBA is behaving abnormally and user intervention is required to correct the problem A malfunction error code indicates that there is a problem with the system but user intervention is not required A command error code indicates that an event has transpired but does not require user intervention An event may be problem oriented such as an invalid fabric command sub type An event may not be problem oriented such as exhausted retries on PLOGI or PDISC Related Driver Parameter LogError The LogError driver parameter determines the minimum severity level to enable entry of a logged error into the system If set to 0 all errors regardless of severity are logged If set to 1 severe malfunction and command level errors are logged If set to 2 both severe and malfunction errors are logged If set to 3 only severe errors are logged Note See the Configuration Section for instructions on how to set driver parameters Storport Miniport Driver User Manual Page 38 Format of an Error Log Entry An error log entry will take the form of an event This event is described by Date date entry was logged e Source elxstor Time time entry was logged e Category none e T
54. tem If these problems persist report these errors to Technical Support Ipfc mes0326 0326 Reset HBA HostStatus x x DESCRIPTION The HBA has been reset SEVERITY Information LOG LOG MBOX verbose ACTION No action needed informational INIT Log Messages 0400 0463 lpfc mes0400 0400 Initializing discovery module OptionFlags x x DESCRIPTION Driver discovery process is being initialized with internal flags as shown SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0401 0401 Initializing SLI module Deviceld x x NumMSI d DESCRIPTION PCI function with device id and MSI count as shown is being initialized for service level interface SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 31 X EMULEX lpfc_mes0405 Service Level Interface SLI 2 selected n DESCRIPTION Service Level Interface level 2 is selected SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0406 0406 Service Level Interface SLI 3 selected n DESCRIPTION Service Level Interface level 3 is selected SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc mes0436 Adapter not ready hostStatus x x DESCRIPTION The adapter failed during powerup diagnostics after it was reset SEVERITY Error LOG LOG INIT verbose ACTION Th
55. the AUTOPILOT CONFIG section of the APInstall cfg file Storport Miniport Driver User Manual Page 16 X EMULEX AutoPilot Installer Error Codes Reference Table AutoPilot Installer sets an exit code to indicate whether an installation was successful or an error occurred These error codes allow AutoPilot Installer to be used in scripts with error handling AutoPilot Installer s silent mode specifically returns the following values Table 3 Unattended Installation Error Codes Error Code Hex Description 0 0x00000000 No errors 2399141889 0x8F000001 No appropriate driver found 2399141890 0x8F000002 The AutoPilot configuration file is not found 2399141891 0x8F000003 Disabled HBAs detected in the system 2399141892 0x8F000004 The selected driver is 64 bit and this system is 32 bit 2399141893 0x8F000005 The selected driver is 32 bit and this system is 64 bit 2399141894 0x8F000006 Other hardware installation activity is pending AutoPilot Installer cannot run until this is resolved 2399141895 0x8F000007 GUI Mode only User cancelled execution because user did not wish to perform a software first install 2399141896 0x8F000008 No drivers found 2399141897 0x8F000009 One or more HBAs failed diagnostics 2399141904 0x8F000010 GUI Mode only User chose to install drivers even though a recommended QFE or Service Pack was not installed 2399141920 0x8F000020 GUI Mode on
56. tility Web Launch Feature cccccecseeeeeeeeeeeeeeeee 10 Updating the HBAnyware Utility Web Launch URL eee eeeeeeeeeeeeteeeeeees 11 Unattended Installation siiras anaana EADAE AEAEE ADAADA 11 AutoPilot Configuration File Format arnnrrnnnnnnnnnonnnnvrrrnnnnnnnrnnnnnrrrrnnnnnnsrrrnnnnn 12 Mandatory Configuration File Changes arrnnnrrrnnnnnnnnnnnnnrrrnnnnnnnrnnnnrrrrnenerrnnnnn 12 Deleting Questions in the APInstall cfg File rrrrnnrrrrrnnrnnrrnnrnnnnnrrrrnnnnnnnnrrnnnn 13 Optional Configuration File Changes rrrnnnnnnnnnnnnvrrrnnnnnnnrnnnnnrrrnnnnnnnrnnnnnnrrnnnne 13 Setting Up Driver Parameters mmmrrrsvrrrrnnnnnnnnvrrrnnnnnnvnnnnrrnnnnrrrnnnnnnnrrnnnnrenennsnn 16 Setting Up System Parameters rrrnnnnrrrrnnnnnnvrnnnnvrrrnnnnnnnrnnnnnrrnnnnnnnnnrnnnnnrrnnene 16 AutoPilot Installer Error Codes Reference Table rrnnrnnnrnnnnnvrrnnnnnnnnnnnnnnrrnnnn 17 Invoking AutoPilot Installer cc ceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeas 18 Batch File Example teed teed tees teen teed theccecedececneacacecceecdeecdenceenciaaneencicadice 18 Manually Installing or Updating the Storport Miniport Driver n 20 ONE EA 00 nn 20 Removing the Adjunct Driver Registry Key rrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnvnnnnnnnnnr 20 Manually Installing the Emulex PLUS ElxPlus Driver for the First Time 20 Manually Updating the Emulex PLUS ElxPIus Driver 21 Manually Installing or Updatin
57. to stop the installation b Figure 3 AutoPilot Installer Warning Software First Installation 2 Click OK 3 A Welcome window appears 4 Click Next Installation automatically completes Storport Miniport Driver User Manual Page 9 X EMULEX 5 View the progress of the installation Once the installation is successful a congratulations window appears 6 View or print a report if desired View Installation Report your text editor typically Notepad displays a report with task results The text file is named in the following format report_MM DD YY txt MM month e DD day e YY year e report number Print Installation Report your default print window is displayed 7 Click Finish to close AutoPilot Installer If the system needs to reboot you are prompted to do so when you click Finish Installing the HBAnyware Security Configurator After the HBAnyware utility and remote server are installed on a group of systems the HBAnyware utility can remotely access and manage the HBAs on any systems in the group This may not be desirable because any system with remote access can perform actions such as resetting boards or downloading firmware The HBAnyware Security Configurator controls which HBAnyware systems can remotely access and manage HBAs on other systems in an FC network HBAnyware security is system based not user based As a result anyone who can access a system with HBAnyware client access to remote
58. to the location of driver s distribution kit If you have downloaded the Storport Miniport files to the default directory the path will be C Program Files Emulex AutoPilot Installer Drivers Storport x86 for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport x64 for the x64 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport lA64 for the Itanium 64 bit driver version 9 Click OK Select Emulex PLUS 10 Click Next to install the driver 11 Click Finish The ElxPlus driver update is complete Continue with manual installation of the Storport Miniport Driver Manually Installing or Updating the Storport Miniport Driver To update or install the Storport Miniport driver from the desktop 1 Select Start gt Control Panel gt System 2 Select the Hardware tab 3 Click Device Manager 4 Open the SCSI and RAID Controllers item 5 Double click the desired Emulex HBA Note The driver will affect only the selected HBA If there are other HBAs in the system you must repeat this process for each HBA All DC models will be displayed in Device Manager as two HBAs therefore each HBA must be updated 6 Select the Driver tab 7 Click Update Driver The Update Driver wizard starts Storport Miniport Driver User Manual Page 21 X EMULEX 8 Select No not this time Click Next on the Welcome to the Hardware Update Wizard window Select
59. u to select a new driver type Select the driver type from the drop down list and click Next If you are installing an older driver version the Available Drivers window is displayed Select the existing driver version from the drop down list and click Next If you are installing a vendor specific version of the Emulex driver installation program this program may include one or more windows with questions that you must answer before continuing the installation process In this case answer each question and click Next on each window to continue 7 View the progress of the installation Once the installation is successful a congratulations window appears 8 View or print a report if desired View Installation Report your text editor typically Notepad shows a report with current HBA inventory and configuration information and task results The text file is named in the following format report_MM DD YY txt MM month e DD day e YY year e report number Print Installation Report your default print window is displayed 9 Click Finish to close AutoPilot Installer If your system requires a reboot you are prompted to do so when you click Finish Storport Miniport Driver User Manual Page 8 X EMULEX If the Installation Fails If the installation fails the Diagnostics window appears To view the reason an HBA failed select the HBA row The reason and suggested corrective action are displayed below the list i
60. wo options Run AutoPilot Installer immediately Run AutoPilot Installer later Running the Distribution Executable File To run the distribution executable file 1 2 3 Download the distribution executable file from the Emulex Web site to your system Double click the distribution executable file A window is displayed with driver version information and Emulex contact information Click Next to access the Installation Folder window or click Cancel to close the window The default installation location is displayed Browse to a different location if desired Click Install to continue the installation The Progress window is displayed As each task completes the corresponding box is automatically selected After all tasks complete a confirmation window is displayed The Start AutoPilot Installer box is automatically selected To start AutoPilot Installer later clear this box Click Finish to close the distribution executable file Storport Miniport Driver User Manual Page 5 X EMULEX AutoPilot Installer Introduction The Emulex AutoPilot Installer wizard installs or updates Emulex drivers and utilities and configures HBAs drivers and utilities One of the following operating systems must be installed e Windows Server 2003 running on an x86 x64 or Itanium 64 bit platform See the Emulex Web site for required updates to the Microsoft Storport driver e Windows Vista running on an x86 or x64 platform Auto
61. xA8 Read check error parameter in bits 8 31 OxAA Node time out DID in bits 8 31 Table 8 Command Errors Bits 0 7 Interpretation 0x32 Insufficient context for attention handling 0x49 ELS command error status in bits 8 31 Ox4A ELS command failure 0x90 ELS FDISC completed NPort IDin bits 24 31 0x91 ELS LOGO completed NPort ID in bits 8 31 0x92 ELS LOGO received from fabric 0x93 ELS FLOGI completed NPort ID in bits 8 31 0x94 ELS PLOGI completed NPort ID in bits 8 31 0x95 Discovered SCSI target NPort ID in bits 8 31 0x96 ELS RSCN received count in bits 8 15 vpi in bits 24 31 0x97 Assigned SCSI address to discovered target address in bits 8 31 0x98 Name server response count in bits 8 31 0x9B SCSI check condition sense codes in bits 8 31 OxA3 Local error on FCP command completion status in bits 8 31 OxA6 Data over run OxA7 Non specific FCP error info in bits 8 31 OxA9 Local error status in bits 8 31 OxAB Pass through command error status in bits 8 31 Storport Miniport Driver User Manual Page 42 XEMULEX Table 8 Command Errors Continued Bits 0 7 Interpretation OxAC Local error on report LUN completion status in bits 8 31 Table 9 Event Indications Bits 0 7 Interpretation 0x21 Port re initialization c
62. y to install the driver Separate folders for each architecture x86 x64 and Itanium 64 bit contain these following files e Deladjct reg File removes registry entries for previous value add driver e elxplus inf Installation script for value add driver This driver supports HBAnyware persistent binding and LUN mapping and masking e elxplus sys Value add driver supporting persistent binding e elxstor pdb Symbol file for Storport Miniport driver e elxstor sys Storport Miniport driver FriendlyName exe Installation program from Windows friendly name entry e oemsetup inf Driver installation script for setup program e txtsetup oem Driver installation script for boot time setup program BootBIOS must be installed Utilities This folder contains files necessary to install HBAnyware and the driver utility The setup exe file installs utilities and related files which include HBAnyware HBAnyware Discovery Server Reports If the system generates reports this folder is generated and the reports are placed here Storport Miniport Driver User Manual Page 4 X EMULEX Distribution Executable File Overview The distribution executable file self extracts and copies the following onto your system AutoPilot Installer Storport Miniport driver ElxPlus driver HBAnyware utility HBAnyware Security Configurator After the distribution executable file runs and the files are extracted you have t
63. you update the Storport Miniport driver manually install the elxplus driver prior to updating the Storport Miniport driver See Manually Installing or Updating the Storport Miniport Driver on page 20 for more information Definitions Driver A host computer software component that controls the operation of peripheral controllers or HBAs attached to the host computer Drivers manage communication and data transfer between applications and I O devices using HBAs as agents The HBAnyware utility This utility allows you to perform installation and configuration tasks on remote and local HBAs See the HBAnyware Utility User Manual for more information The HBAnyware Security Configurator The HBAnyware security package allows you to control which HBAnyware systems can remotely access and manage HBAs on other systems in a Fibre Channel FC network See page 10 for the installation procedure See the HBAnyware Utility User Manual for more information Web Launch A feature that allows you to start the HBAnyware utility directly from your Web browser See the HBAnyware Utility User Manual for more information Storport Miniport Driver User Manual Page 2 X EMULEX Storport Miniport Driver Information Prerequisites One of the following operating systems e Windows Server 2003 running on an x86 x64 or Itanium 64 bit platform e Windows Vista running on an x86 or x64 platform e See the Emulex Web site for required updates to the Micro
64. ype error Event id 0 User N A Computer name of computer X EMULEX The relevant word from the elxstor point of view is at offset 0x10 Bits 0 7 of the word at offset 0x10 are the error code Error Codes Tables Table 6 Severe Errors Bits 0 7 Interpretation 0x00 Failed to allocate PCB 0x01 Failed to allocate command ring 0x02 Failed to allocate response ring 0x03 Failed to allocate mailbox context 0x04 Read revision failed 0x05 Invalid adapter type 0x06 Invalid adapter type 0x07 Write of non volatile parameters failed 0x08 Invalid link speed selection 0x09 Read configuration failed 0Ox0A Set variable failed 0x0B Configure port failed 0x0D Configure ring 0 failed Ox0E Configure ring 1 failed OxOF Configure ring 2 failed 0x10 Configure ring 3 failed 0x11 Initialize link failed 0x12 Port ready failed 0x13 Read revision failed 0x14 Invalid adapter type 0x15 Invalid adapter type 0x17 Set variable command failed 0x18 Configure port failed 0x19 Configure ring 0 failed Storport Miniport Driver User Manual Page 39 Table 6 Severe Errors Continued XEMULEX Bits 0 7 Interpretation Ox1A Configure ring 1 failed 0x1B Configure ring 2 failed Ox1C Configure ring 3 failed Ox1E Context pool initiali
65. zation failure Ox1F Context pool initialization failure 0x20 Context pool initialization failure 0x24 Firmware trap fatal adapter error 0x25 Non specific fatal adapter error bits 8 31 will indicate type 0x29 Recoverable adapter error device has been auto restarted Ox2A Mailbox command time out 0x2D Invalid Illegal response IOCB Ox2E Invalid response IOCB OX2F Invalid response IOCB 0x30 Mailbox context allocation failure 0x34 Mailbox context allocation failure 0x35 Mailbox context allocation failure 0x37 Mailbox context allocation failure 0x3D Mailbox context allocation failure 0x41 Mailbox context allocation failure 0x42 Mailbox context allocation failure 0x44 ELS FLOGI command context allocation failure 0x47 Mailbox context allocation failure 0x4D Mailbox context allocation failure 0x51 Request to ADISC a non existent node 0x52 ELS ADISC command context allocation failure 0x56 Mailbox context allocation failure 0x57 Mailbox context allocation failure 0x58 ELS LOGO command context allocation failure 0x5C ELS PRLI command context allocation failure Ox5E ELS RLIR command context allocation failure 0x64 Create XRI command context allocation failure 0x67 Name server command context allocation failure Ox6E Close XRI command context allocation failure Ox6F State change registration failure 0x70 ELS receive context allocation failure 0x72 ELS receive PLOGI context allocation failure 0x74 Mailbox context allocation failure