Home
        Absolute Manometer by OMEGA® HHP360
         Contents
1.     3  Press the PRGM key  Bottom line shows serial  number     4  Press the up arrow key Top line reads    HEADER   five times  NAME    and bottom line  reads    text     The cursor  flashes at bottom left    5  If header is correct press Top line reads    PROGRAM   backspace key  If editing is   MODE    and bottom line   desired proceed to step 7  reads    USER INFO    SELECT        6  Press the left arrow key  Returns to Measure Mode     7  Press the up or down Displays a number between 0  arrow keys to set the and 9  a letter from A to Z       correct alpha numeric or a blank space   value     8  Press the right arrow key   Cursor advances one space to  to accept entry  right     9  Repeat steps 8 and 9   until the desired Header is   shown    10  If an error is made press   the back arrow key until the   cursor is over the incorrect   value  Follow step 8 to   correct  Press the right   arrow key to advance the   cursor without changing   values    11  When the Header is Top line reads    PROGRAM  complete press the PRGM   MODE    and bottom line  key until header accepted  reads    UNITS SELECT        12  Press the left arrow Returns to Measure Mode   key        21 of 32    Contrast Select    The Contrast Select register allows the user to adjust the character  contrast of the LCD display to provide the best visibility for the  ambient light conditions     To adjust the contrast  follow these steps     Keystroke Display    1  From the Measure Mode Top line reads    PROG
2.     The bottom line reads    UNITS SELECT     Press the A or  W arrow keys to scroll through the Program Mode to the desired  register  The configurable registers found in the Program Mode  are Units Select  Damp Rate Select  User Info Select  Contrast  Select  Sea Level Select  Data Logging  Leak Test and Exit   Press the PRGM key to select any of these configurable registers   The manometer can be put into Program Mode at any time during  Measure Mode operation by pressing the PRGM key  If Lockout  is set  the correct code must be entered when prompted  see the  User Info   Lockout section of this manual for more information on  Lockout      10 of 32    Units Select    The standard engineering units available on the HHP360 Precision    Absolute Manometer are     inches of Mercury at 0   C  in Hg   0   C   millimeters of Mercury at 0   C  mm Hg   0   C     PSI   milliBars  mBar    Bars   kPa   Torr   Feet  Altitude displays   Meters  Altitude displays     To change the engineering units the manometer should be    ON     and in Measure Mode  Then follow these steps     Keystroke    1  Press the PRGM key     2  Press the PRGM key       Press the Aor Warrow  key until desired engineer   ing unit is displayed    4  Press the PRGM key to  select the engineering unit     5  Press the W arrow key     6  Press the PRGM key     Top line reads    PROGRAM  MODE    and bottom line reads     UNITS SELECT       Top line reads    UNITS  SELECT    and bottom line  shows current engineering 
3.   Turns the manometer on and enters the unit into the Measure  Mode  Pressing the key while in the Measure Mode turns the unit  off  It also serves as a backspace key when editing in the Program  Mode  The q key takes the user out of a programmable register  without changing the previous setting  Pressing this key repeatedly  will return the user to the Measure Mode and then shut off the  manometer     MIN MAX  amp  UP A KEY    In the Measure Mode activates the Min Max function of the  manometer  When activated the minimum value is displayed on the  upper left of the display and the maximum value on the upper  right  This key also deactivates and resets this function  The A key  is used to scroll through the programmable registers when the unit  is in the Program Mode  Once a programmable register is selected  thew key can be used to edit that register           TARE  amp  DOWN VW KEY   In the Measure Mode toggles on off the Tare function  The Tare  function is designed to set the display value to    0     With Tare  activated  the letter    T    appears in the lower left of the display   The W key is used to scroll through programmable registers with  the unit in the Program Mode  Once a programmable register is  selected the W key can be used to edit that register        PRGM  amp  ENTER KEY   Puts the manometer into the Program Mode from the Measure  Mode  When in the Program Mode  pressing this key selects the  programmable register to be edited  with prompt for password 
4.  66342 TEL   420 59 6311899  FAX   420 59 6311114 e mail  info omegashop cz  Managed by the United Kingdom Office   Toll Free  0800 466 342 TEL   33  0  161 37 29 00  FAX   33  0  130 57 54 27 e mail  sales omega fr    Daimlerstrasse 26  D 75392 Deckenpfronn  Germany    Toll Free  0800 6397678 TEL   49  0  7056 9398 0  FAX   49  0  7056 9398 29 e mail  info omega de  OMEGA Engineering Ltd     One Omega Drive  River Bend Technology Centre  Northbank  Irlam  Manchester M44 5BD United Kingdom   Toll Free  0800 488 488 TEL   44  0  161 777 6611  FAX   44  0  161 777 6622 e mail  sales omega co uk    It is the policy of OMEGA Engineering  Inc  to comply with all worldwide safety and EMC EMI  regulations that apply  OMEGA is constantly pursuing certification of its products to the European New  Approach Directives  OMEGA will add the CE mark to every appropriate device upon certification    The information contained in this document is believed to be correct  but OMEGA accepts no liability for any  errors it contains  and reserves the right to alter specifications without notice    WARNING  These products are not designed for use in  and should not be used for  human applications     USER MANUAL    PRECISION ABSOLUTE MANOMETER    The Precision Absolute Manometer is a microprocessor based  pressure sensing device used to directly measure pressure  relative to absolute zero  Model HHP360 A measures pressure  from 0     17 403 PSIA and model HHP360 B measures  pressure from 0     38 6
5.  correction  set   DISABLED on the 2    line   and skip ahead to step 12     7  To change the value press Top line reads    VALUE     the A key to toggle the 00000000     Bottom line   display to    YES     reads    CHANGE    YES           15 of 32    8  Press the PRGM key  Top line reads    SEA Top  line reads    SEA  LEVEL METERS     Bottom  line reads    000000007    9  Press the Aor Warrow Top line reads    SEA   keys to set the correct value LEVEL METERS     Bottom   in the first digit  line reads    70000000        10  When the value is correct   Cursor moves over to the  press the PRGM key  next digit     11  Repeat steps 9 and 10 Top line reads    SEA  above until the correct LEVEL METERS     Bottom  elevation is entered  line reads    700 0000        12  Press the PRGM key to Top line reads    PROGRAM  continue moving the cursor MODE     Bottom line reads    to the right  When the last    UNITS SELECT      digit is entered the unit will   leave the sea level select   mode and return to the   Program Mode     13  Press the 4 key  The Display reads    display will return to the    S 803 1 TORR     Measure Mode  When the   Correction to Sea Level is   ENABLED  the display will   have the letter    S    at the   beginning of the 2    line        16 of 32    Damp Rate Select   Adjustable exponential type damping is available to steady the  display when measuring pulsating pressures  The HHP360 has a  range of damping rates  0 1  0 2  0 5  1  2  5  10  or 25 seconds   Damp
6.  defaults     NO       5  Press the PRGM key at Top line reads    RE CAL      YES to restore the Factory Bottom line reads  Default Calibration data or    RESTORE DEFAULTS     at NO to exit without A  f Factory defaults have been  restoring   restored     6  Press the left arrow key  Returns to Measure Mode        29 of 32    Specifications       Type  Range and Display Resolution   HHP360 A  0   17 403 psia  0   900 00 mmHg   HHP360 B  0   38 674 psia  0   2000 0 mmHg        Accuracy   HHP360 A  0017   0 02   F S   F S    900 mm Hg   HHP360 B  0038   0 015   F S   from 0 1000 mm Hg   0 025  F S   from 1000 2000 mm Hg   F S    2000 mm Hg Absolute  Includes the combined effects of temperature  linearity   repeatability  hysteresis and resolution     Warm up time   5 minutes        Temperature   Storage    40  C to  60  C   40  F to  140  F   Operating    20  C to  50  C   4  F to  122  F        Media Compatibility   AI  Absolute pressure sensors for use with gases and liquids  compatible with 316L SS       Pressure Limits   AI units  77 PSIA  4000 mm Hg Abs        Connection   1 8    female NPT  316L SS  P1 is the pressure connection   P2 is not accessible  factory plugged with metal disc        User must use a wrench on the pressure manifold when  installing user   s 1 8    NPT fitting  Do not tighten the  fitting without using a wrench on the pressure  manifold  Failure to use a wrench on the manifold will  damage the plastic enclosure and void warranty No  torque should be 
7.  method allows the user to enter  any pressure value when a known reference is applied  for  example  the local barometer   The manometer will compare  its actual measured value with the entered value  and calculate  a new zero reference based on the offset     1  To zero the manometer using Referenced to Absolute    Zero  start with the unit turned OFF and use the following  keystroke sequence     5 of 32    1  Press ON OF button     2  Connect the HHP360  to a vacuum source  capable of a vacuum of  100 microns absolute  pressure or less     3  Pull a full vacuum     4  Press MIN MAX and  TARE keys at the same  time   See figure 1  below      5  Press the PRGM key     The display briefly shows  the header name and full  scale range of the unit in the  last engineering units  selected  The manometer  then goes into the Measure  Mode where the applied  pressure and engineering  unit of measure are  displayed     Display should read close to  zero   See note on next  page     Top line of display reads     ZEROING SOURCE      Bottom line of display reads     REF TO ABS ZERO       Top line of display reads     ZERO IN PROGRESS     while bottom line counts  down from 9  Zeroing is  complete when unit returns  to Measure Mode        Figure 1    6 of 32    2  To zero the manometer using Factory Zero  start with the    unit turn ON and in Measure Mode and use the following  keystroke sequence     Press MIN MAX and   Top line of display reads   TARE keys at the    ZEROING SOURCE      
8.  must first restore the re calibration data to  the factory defaults     25 of 32    RE CALIBRATION     1 Point EDIT and START       To perform a 1 point re calibration  apply a pressure between 50   and 100  of Full Scale and then follow these steps     Keystroke Display  1  With unit OFF  press and Top line reads    RE CAL        hold the MIN MAX key  Bottom line reads    EDIT      turn the unit on by pressing    the ON OFF key  then  release MIN MAX     2  Press the up arrow key Top line reads    RE CAL      until    START    is displayed Bottom line reads    START      on the bottom line     3  Press the PRGM key  Top line reads    RE CAL  START      Bottom line reads    1   POINT        4  Press the PRGM key  Top line reads    CAL  POINT    and bottom line  displays the cal point value     5  Press the up down arrow Bottom line displays the cal   keys to edit the selected point value  The cursor   digit  Use the left right arrow   flashes at the first position   keys to change the cursor while the value is changed    position  Value entered must     be 50 100  of FS  then moves to the right  position when the right  arrow key is pressed    6  Press the right arrow key Top line reads    APPLY       while on the right most digit Bottom line displays the   to proceed     CAL POINT    value    7  Apply the input pressure Top line reads    RE CAL       indicated using an Bottom line reads    START        appropriate reference M ter has b  standard  press PRGM key  i rated ape
9.  same time   See Bottom line of display   figure 1 above   reads    REF TO ABS  ZERO       Press Aor Warrow Bottom line of display   key until desired zero   reads    FACTORY ZERO     function is shown on   the bottom line     Press the PRGM key  Zeroing is complete when    unit returns to Measure  Mode        NOTE  The HHP360 can be zeroed only if the new applied  zero is within   1  FS of the original factory calibration zero   If outside this limit a    ZERO RANGE ERROR    message  appears and the manometer will not zero  Contact the factory  for support in this case     3  To zero the manometer using User Adjusted Zero  start  with the unit turn ON and in Measure Mode and use the  following keystroke sequence     7 of 32    Apply a known   accurate pressure  source  This may be  true atmospheric  pressure  with known  reference defined by a  local barometer     Press MIN MAX and  TARE keys at the  same time   See  figure 1 above      Press A or Warrow  key until desired zero  function is shown on  the bottom line     Press the PRGM key     Press any of Aor Y  arrow key or the  PRGM key to begin  editing     Example  set current  pressure value to 29 5  In Hg   0  C     Top line of display reads     ZEROING SOURCE        Bottom line of display  reads    REF TO ABS  ZERO       Bottom line of display  reads    USER ADJ   ZERO       Top line of display shows  the current non zero  compensated pressure  value  Bottom line of  display shows the same  value  along with the  engi
10.  that the primary standard be 4 times more accurate than  the unit under test     The re calibration is not intended to replace the Factory Lab  Calibration Procedure  It is intended to correct the curve fit if the  actual sensor characteristics change slightly over time     For sensors up to 200 PSI  a  0 0015  of reading deadweight  tester is recommended     1 point  within upper 50  of Full Scale   5 point  nominal values  of 0   25   50   75   amp  100  of Full Scale   and restore factory  default re calibration options are offered  For the 5 Point re   calibration  points 2  3 and 4 can be adjusted within  1  of  reading around the nominal values  Point  5 can be adjusted within   1  of reading around nominal  Point  1 is fixed    For example  for a 2000 inH20 sensor  Point   2  25   can be  edited form 495 to 505 inH20  Point  5  100   can be edited  from 1980 to 2000 inH20     The unit can only be re calibrated if the calibration points are  within 5 times the accuracy of the original factory calibration  e g     0 05  accuracy  the point limit is  0 25  of Full Scale   If the  re calibration procedure generates a new value outside this limit  the procedure will fail  In this case the unit would need to be  returned to the factory for service     Once a re calibration has been performed  either 1 point or 5   point  the unit will continue to allow future re calibrations only  with that type of re calibration  In order to enable the other re   calibration type  the user
11.  the Measure Mode Top line reads    PROGRAM  MODE    and bottom line  reads    UNITS SELECT      Bottom line reads    LEAK  twice  TEST       3  Press the PRGM key  Top line reads    LEAK  TEST    and bottom line reads     CONFIGURE       4  Press the PRGM key  Top line reads    Leak Test  Period     amp  bottom    X X  MIN       5  Use the up  down  amp  right   Bottom line reads desired   keys to input test period period  Ex     20 0 MIN        6  Press the PRGM key  Top line reads    LEAK  TEST    and bottom line reads     CONFIGURE        7  Press the up arrow key Top line reads    LEAK   once  TEST    and bottom line reads     PRGM TO START       8  Press the PRGM key  Top line displays MIN MAX  pressure values at left right   Bottom line reads the current  pressure value and units     At end of test period  top line  displays the leak rate in units  per minute  Bottom line  shows the current pressure  reading     9  Press the PRGM key to Returns to Measure Mode  exit the Leak Test    The    Auto Shut Off    timer is disabled for Leak Test sessions  Be sure to end  the session to re enable the Auto Shut Off timer        24 of 32    Re Calibration    The HHP360 can be re calibrated in the field for zero  span  and  linearity  The proper primary standards must be available prior to  calibrating the unit  These standards should meet the accuracy  requirements for your company or industry  The factory follows  guidelines established by ANSI   NCSL Z540 1 1994 which  requires
12.  units     Engineering units on bottom  line of display change     Top line reads    PROGRAM  MODE    and bottom line reads     UNITS SELECT       Display returns to Measure  Mode in new engineering unit        11 of 32    Displaying Altitude  US Standard Atmosphere 1962        The model HHP360 is capable of displaying altitude in feet or  meters based on U S  Standard Atmosphere1962 tables  To set the  unit to read out referenced to this altitude standard use the  following steps     Keystroke Display    1  Press the PRGM key  Top line reads    PROGRAM  MODE    and bottom line reads     UNITS SELECT        2  Press the PRGM key  Top line reads    UNITS  SELECT    and bottom line  shows current engineering  unit      Press the Aor Warrow Top line reads    UNITS   key until    USER UNIT SELECT      SELECT    is displayed  Bottom line reads    FEET or  METERS        4  Press the PRGM key  Top line reads    ALTITUDE  SELECT     Bottom line reads     STANDARD       5  Press the PRGM key  Top line reads    PROGRAM  MODE    and bottom line reads     UNITS SELECT        6  Press the qkey  Manometer returns to Measure  Mode  Displays altitude  referenced to US Standard  Atmosphere 1962        Display User Defined Altitude    User Defined Altitude is useful in determining elevation change  from a map elevation reference or from a survey trig marker  elevation  To set up the HHP360 to display altitude based on user  entered information  use the following steps     Keystroke Display    
13. 1  Press the PRGM key  Top line reads    PROGRAM  MODE    and bottom line reads     UNITS SELECT           2  Press the PRGM key  Top line reads    UNITS  SELECT    and bottom line    shows current engineering  unit     3  Press the A or Warrow Top line reads    UNITS       12 of 32    key until    FEET    or     METERS     is displayed     4  Press the PRGM key     Press the Aarrow key  once     6  Press the PRGM key     7  If the value shown in  step 6 is the correct  altitude  press the PRGM  key to accept and the 4  key to return to Measure  Mode      OR     If the value shown in step  6 is not the correct  altitude  press the W key    8  Press the PRGM key     Example  set altitude to  685 feet above sea level     9  Press the Aor Wkeys to  set the first digit to    6        Using the Akey the  provides the character  sequence 0   9      negative  and     decimal  point  The       sign is used  if your location is below  sea level     10  When the digit is  correct press the PRGM  key     If an error is made use the  back space qkey to move  the cursor back to the  incorrect digit  Press the A  or Warrow keys to display  the correct value     SELECT      Bottom line reads    FEET or  METERS       Top line reads    ALTITUDE  SELECT     Bottom line reads     STANDARD       Top line reads    ALTITUDE  SELECT     Bottom line reads     REF  TO USER       Top line reads    VALUE    00000000     Bottom line reads     CHANGE   NO       Top line reads    PROGRAM  MODE    and bott
14. 74 PSIA  Pressure can be displayed in a  variety of English and S I  engineering units  All HHP360s  include a Tare function  a Min Max function  selectable damp  rates and altitude displayed in feet or meters  The HHP360  can also display barometric pressure corrected to sea level        1 of 32    Table of Contents              User Interface        3  1  Keypad Functions    wo  ON OFF  amp  BACK A KEY  uo  MIN MAX  amp  UP A KEY   Leo  TARE  amp  DOWN WKEY    w3  PRGM  amp  ENTER P KEY     6000s000s00dn 089 dn 058 naas anaa nengarani 3  BACKLIGHT REY  easiest seison ra 9 Laa haaa anana 04 4  2  Zeroing the Manometer wI  3  Program Mode             10  Units Select ll  Displaying Altitude  US Standard Atmosphere 1962                 12  Display User Defined Altitude  sssrinin 12  Pressure Corrected to Sea Level AS  Damp Rate Select 0 0    7                User Info Select   18  Auto Shut Off sae  LOC KODES LECU aaa RA AARS 20  Header Name        21  Contrast Select    ae  Data Logging    23   Co a  ee arani aaa NANANG NANANG ANANGENG Aa 24  ReeC a DTAUON issassasaassaueveves A 25  RE CALIBRATION     1 Point EDIT and START   26  RE CALIBRATION     5 Point EDIT                  27  RE CALIBRATION     5 Point START             h 27    RE CALIBRATION     Restore Factory Defaults  Specifications         Certification Safety Warnings   Chanoine the Bates 5 5 agan aana EA GE KA GK AAN Ega a a aaa 31    2 of 32    User Interface       1  Keypad Functions    ON OFF  amp  BACK A KEY 
15. Bottom line reads    1   POINT       Top line reads    RE CAL  START       Bottom line reads    5   POINT       Top line reads    POINT 1    ZERO       Bottom line displays live  applied pressure    Unit takes new zero  Top line  reads    POINT 1   ZERO      Bottom line displays live  applied pressure  POINT 1  has been taken    Top line reads    POINT 2    APPLY        Bottom line displays the cal  point value to apply    Top line reads    POINT 3    APPLY        Bottom line displays the cal  point value to apply     Top line reads    POINT 4 5    APPLY      Bottom line displays the cal  point value    Top line reads    SAVE       Bottom line reads    NO    or     YES        Top line reads    RE CAL      Bottom line reads    START      Re cal is complete        12  Press the left arrow Returns to Measure Mode   key     28 of 32    RE CALIBRATION     Restore Factory Defaults       To restore the re calibration data to the factory defaults  follow  these steps     1  With unit OFF  press and Top line reads    RE CAL      hold the MIN MAX key  Bottom line reads    EDIT      turn the unit on using the  ON OFF key  then release   2  Press the up arrow key Top line reads    RE CAL      twice  Bottom line reads     RESTORE DEFAULTS      3  Press the PRGM key  Top line reads    RESTORE  DEFAULTS      Bottom reads    YES    or     NO      4  Use the up and down Top line reads    RESTORE  arrow keys to select YES or DEFAULTS        NO when asked to restore Bottom reads    YES    or   
16. It also allows  the user to edit the Auto Shut Off  Lockout and Start Up Header  Name features     To access the User Info Select registers  follow the steps below  To  configure a User Info Select register  follow the steps shown on the  following page     Keystroke Display  1  From the Measure Mode Top line reads    PROGRAM  press the PRGM key  MODE    and bottom line  reads    UNITS SELECT        2  Press the Aarrow k Bottom line changes to  number     ey  y   4  Press the A arrow key  Software version number  shown   ey     5  Press the Aarrow k Manufacture date shown   6  Press the Aarrow key  Top line reads    AUTO SHUT    See instructions to set OFF    and bottom line reads  AUTO SHUT OFF later in    ENTER TO SELECT        this manual   7  Press the Aarrow key  Top line reads    LOCKOUT  See instructions for using CODE    and bottom line reads    LOCKOUT later in this    ENTER TO SELECT      manual     8  Press the Aarrow key  Top line reads    HEADER   See instructions for editing NAME    and bottom line   the Header later in this reads    text     The cursor   manual  flashes at bottom left    9  Press the 4arrow key Top line reads    PROGRAM   to go back to    USER MODE     and bottom line   INFO SELECT    screen  reads    USER INFO  SELECT              18 of 32    Auto Shut Off    Enabling the Auto Shut Off feature allows the manometer to turn  itself off after a user selected period of keypad inactivity   Selectable options include DISABLED  10 Minutes  which is t
17. MADE IN    A YEAR         WARRANTY USA          User s Guide                Shop online at      omega con   Y    CEOMEGA       omega com  e mail  info omega com  For latest product manuals   omegamanual  info                         OMEGA  HHP SE 60 A       HHP360 Series    Precision Absolute Manometer       omega Com   CEOMEGA                OMEG Anet  Online Service Internet e mail  omega com info omega com             U S A    ISO 9001 Certified    Canada     Servicing North America     Omega Engineering  Inc   One Omega Drive  P O  Box 4047  Stamford  CT 06907 0047    Toll Free  1 800 826 6342 Tel   203  359 1660   FAX   203  359 7700 e mail  info omega com  976 Bergar   Laval  Quebec   H7L 5A1 Canada   Toll Free  1 800 826 6342 TEL   514  856 6928  FAX   514  856 6886 e mail  info omega ca    For immediate technical or application assistance     U S A  and Canada     Mexico  Latin America    Benelux     Czech Republic     France     Germany Austria     United Kingdom   ISO 9001 Certified    Sales Service  1 800 826 6342   1 800 TC OMEGA    Customer Service  1 800 622 2378  1 800 622 BEST    Engineering Service  1 800 872 9436  1 800 USA WHEN      En Espa  ol  001  203  359 7803 FAX  001  203  359 7807  info omega com mx e mail  espanol omega com    Servicing Europe     Managed by the United Kingdom Office  Toll Free  0800 099 3344 TEL   31 20 347 21 21  FAX   31 20 643 46 43 e mail  sales omegaeng nl    Frystatska 184  733 01 Karvin    Czech Republic    Toll Free  0800 1
18. RAM  press the PRGM key  MODE    and bottom line  reads    UNITS SELECT        2  Press the A key three Bottom line reads  times     CONTRAST SELECT        3  Press the PRGM key  Top line reads    CONTRAST  SELECT     Bottom line shows  a numerical value    4  Press the Aor W keys to LCD lightens or darkens    increase or decrease the depending on the value set   contrast value  A low    number gives maximum   contrast and a high number   gives minimum contrast    5  Press the PRGM key  Top line reads    PROGRAM  MODE    and bottom line  reads    UNITS SELECT        6  Press the  lt  key  Returns to Measure Mode     If an error is made during the contrast adjustment  pressing the  key  returns the display to the previous contrast setting        22 of 32    Data Logging   Data Logging can be used to record pressure measurements  Two  record modes are supported  automatic and manual  In automatic  mode  a pressure value is captured every 5 seconds for 20 minutes   resulting in 240 stored values  In manual mode  a pressure value is  captured each time the PRGM key is pressed up to 240 values  The  data collected during a logging session can be viewed upon  completion     1  From the Measure Mode Top line reads    PROGRAM  press the PRGM key  MODE    and bottom line  reads    UNITS SELECT        2  Press the up arrow key Bottom line reads    DATA   five times  LOGGING       3  Press the PRGM key  Top line reads    DATA  LOGGING    and bottom line  reads    RECORD        4  Press 
19. Sea Level is reguired so that barometric  readings can be compared at different elevations  The correction to  sea level is done using a    hypsometric equation     This equation  simulates a    fictitious column of air    which extends downward  from the instruments location to sea level  This fictitious column is  assumed to be similar to the actual air column over nearby lower  elevations  Some properties are related to observed conditions  while others must be assumed  Barometric pressures given by the  National Weather Service and used at airports are always corrected  to sea level     To set the unit to display pressure corrected to sea level     1  Determine the elevation of   the instrument above sea   level  in meters  700 meters   will be used as an example    2  From Measure Mode press   Top line reads    PROGRAM   the PRGM key  MODE     Bottom line reads     UNITS SELECT        3  Press the Aor W key Top line reads    PROGRAM   until    SEA LEVEL MODE     Bottom line reads   SELECT    is displayed     SEA LEVEL SELECT       4  Press the PRGM key  Top line reads    SEA  LEVEL SELECT     Bottom  line reads either    ENABLE     or    DISABLED       5  Press the Aor W key to Bottom line toggles between   indicate the correction to    ENABLE    and   sea level status     DISABLED       6  To turn on the correction  Top line reads    VALUE     set ENABLED on the 2 00000000     Bottom line   line  amp  press the PRGM key  reads    CHANGE      OR  NO       To turn off the
20. applied to the manifold with respect  to plastic enclosure        Battery Operation    gt 100 hours continuous use    year shelf life  auto power off  programmable at Disabled  10  20  30  60 or 90 minutes       Enclosure   6 9  x 3 8  x 2 3   Polycarbonate  Permanently  Static Dissipative  ESD Protection  Enclosure with Boot   7 2  x 4 2  x 2 5               30 of 32    Certification Safety Warnings  The HHP360 is for general purpose use only   Note the following WARNINGS and requirements     e Substitution of components may impair operation     Do not use or service in the presence of explosive  atmospheres      Do not replace batteries in the presence of explosive  atmospheres    e User must use a wrench on the pressure manifold when  installing user   s 1 8    NPT fitting  Do not tighten the fitting  without using a wrench on the pressure manifold  Failure to  use a wrench on the manifold will damage the plastic  enclosure and void warranty No torque should be applied to  the to the plastic enclosure while installing 1 8    NPT fittings     Changing the Batteries    Adherence to the Specifications and Certification Safety Warnings  sections of this manual shall be enforced when changing batteries     The manometer is powered by four  1 5 volt AA size batteries   When the output of the batteries under load drops  the display will  alternate between    LOW POWER DETECT    and    REPLACE  BATTERY     Low power may affect performance  The unit should  not be used to measure p
21. e not  limited to contact points  fuses  and triacs     OMEGA is pleased to offer suggestions on the use of its various products  However   OMEGA neither assumes responsibility for any omissions or errors nor assumes  liability for any damages that result from the use of its products in accordance with  information provided by OMEGA  either verbal or written  OMEGA warrants only  that the parts manufactured by the company will be as specified and free of  defects  OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY  KIND WHATSOEVER  EXPRESSED OR IMPLIED  EXCEPT THAT OF TITLE  AND ALL  IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND  FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED  LIMITATION OF  LIABILITY  The remedies of purchaser set forth herein are exclusive  and the total  liability of OMEGA with respect to this order  whether based on contract  warranty   negligence  indemnification  strict liability or otherwise  shall not exceed the  purchase price of the component upon which liability is based  In no event shall  OMEGA be liable for consequential  incidental or special damages     CONDITIONS  Equipment sold by OMEGA is not intended to be used  nor shall it be used   1   as a    Basic Component    under 10 CFR 21  NRC   used in or with any nuclear installation or  activity  or  2  in medical applications or used on humans  Should any Product s  be used in or  with any nuclear installation or activity  medical application  used on humans  
22. eads    CAL POINT  2 3 4 5     Bottom line  displays the cal point value   Top line reads    RE CAL      Bottom line reads    EDIT        Top line reads    RE CAL      Bottom line     START      Continue with 5 Point Re   calibration procedure at step  3 on next page    OR   Returns to Measure Mode        RE CALIBRATION     5 Point START       To begin the 5 point re calibration procedure  turn the unit OFF    and follow the steps below     27 of 32    Keystroke Display  Top line reads    RE CAL      Bottom line reads    EDIT      Top line reads    RE CAL      Bottom line reads    START        1  Press and hold the  MIN MAX key  Turn unit  on using the ON OFF key   2  Press the up arrow key  until    START    is displayed  on the bottom line    3  Press the PRGM key     4  Press the up arrow key  until    5 POINT    is  displayed on the bottom  line     5  Press the PRGM key     6  Vent Pl and P2 ports to  atmosphere and  simultaneously press the  MIN MAX and HOLD  keys  then release     7  Press the right arrow key  while on the right most  digit to proceed     8  Apply the indicated  calibration point pressure  using external pressure  standards  After pressure is  stable  press the right arrow  key    9  Repeat step 8 for CAL  POINTS 4 and 5     10  Use up or down arrow  keys to select NO or YES  when asked    Save     the  Re Calibration data    11  Press the PRGM key at  YES to save the Re   Calibration data or at NO to  exit without saving     Top line reads    RE CAL  
23. he  factory shipped default   20 Minutes  30 Minutes  45 Minutes and  60 Minutes  Disabling this feature limits the manometer to being  turned off by using the ON OFF key only     To configure auto shut off follow these steps     Keystroke Display  1  Follow steps 1 6 inthe   Top line reads    AUTO SHUT   User Info Select table  OFF    and bottom line reads     ENTER TO SELECT      2  Press the PRGM key  Top line reads    AUTO SHUT   then the up or down OFF    and bottom line toggles to  arrow keys until the    DISABLED        10        20        desired shut off time is   30       45    and    60    minutes  shown  2 i    3  Press the PRGM key  Desired Auto Shut Off time is  selected  top line reads    AUTO  SHUT OFF    and bottom line  reads    ENTER TO SELECT        4  Press the left arrow Returns to Measure Mode   key three times        Note  The    Auto Shut Off    timer is suspended during Data  Logging and Leak Test sessions to prevent accidental loss of  information  Auto Shut Off is re instated after completion of Data   Logging or Leak Test sessions     19 of 32    Lockout Select    Enabling the Lockout feature prevents unauthorized users from  making changes to the configuration of the manometer  To enter  the Program Mode  the user must first enter the    password     two   digit Lockout Code  within approximately 40 seconds when  prompted  Failure to enter the correct two digit code within  approximately 40 seconds will return the unit to Measure Mode   Any two d
24. if  Lockout is set   After the register has been edited  pressing the       3 of 32    PRGM key enters the new setting into the manometer s non   volatile memory  This key also acts as a forward spacep key when    editing user input such as the header name and user units     BACKLIGHT KEY  The BACKLIGHT key  represented by the standard light bulb  symbol  toggles the display backlight between green and off     4 of 32    2  Zeroing the Manometer    The HHP360 is a stable and precise instrument  However  on  occasion the handheld should have a new zero taken  This is done  to remove zero drift that can occur since it was last zeroed  The  HHP360 can be zeroed only if the new applied zero is within   1   FS of the original factory calibration zero  This prevents  accidental zeroing at atmospheric pressure or other relatively high  pressures  If outside this limit a    ZERO RANGE ERROR     message appears and the manometer will not zero     The HHP360 provides three mechanisms for re zeroing     1  Referenced to Absolute Zero  This traditional and  preferred method takes a    snapshot    of the measured pressure  when a vacuum of less than 100 microns Absolute is applied  to the sensor     2  Factory Zero  This method restores the calibration curve to  the original zero taken at the factory  Note that this feature is  intended for comparison purposes  and should not be used for  real pressure measurement  as any zero drift will not be  compensated     3  User Adjusted Zero  This
25. igit numeric code can be programmed  The factory  Lockout Code of 00  which is the default as shipped from the  factory  disables the Lockout     To set the Lockout Code follow these steps     Keystroke Display  1  From the Measure Top line reads    PROGRAM  Mode press the PRGM MODE     and bottom line reads    key  If the Lockout is set     UNITS SELECT      enter the correct g       password    when  prompted     2  Press the up arrow key Bottom line reads    USER  twice  INFO SELECT        3  Press the right arrow Top line reads    LOCKOUT   key then the up arrow key   CODE    and bottom line reads   four times     ENTER TO SELECT       4  Press the right arrow Bottom line shows the old   key  then press the up or Lockout Code  The cursor   down arrow keys to flashes at the first position   Sie the first digit  while the value is changed  the   ress the right arrow key R   to proceed  cursor moves to the right  position once the right arrow  key is pressed    5  Press the right arrow Top line reads    LOCKOUT   key when the desired code   CODE    and bottom line reads    is set  Lockout is    ENTER TO SELECT     activated  i    6  Press the left arrow Returns to Measure Mode   key twice        20 of 32    Header Name  Follow the steps below to edit the Header Name     1  From the Measure Mode   Top line reads    PROGRAM  press the PRGM key  MODE    and bottom line  reads    UNITS SELECT        2  Press the up arrow key Bottom line changes to   twice     USER INFO SELECT   
26. ing is done by averaging new data from the pressure sensor  against previously collected data  The microprocessor collects data  from the sensor every 0 1 seconds  The display updates every 0 5  seconds  showing the current 0 1 second pressure reading  When set  at 25 seconds  the display updates every 0 5 seconds with the  average of the previous 25 seconds readings  Therefore  it takes up  to 25 seconds from the time pressure is applied until the manometer  displays the full scale applied pressure  Min Max display updates  every 0 1 seconds     To set the damp rate     1  Enter Program Mode by Top line reads    PROGRAM  pressing the PRGM key  MODE     Bottom line reads     UNITS SELECT        2  Press the A key  Bottom line reads    DAMP  RATE SELECT       3  Press the PRGM key  Top line reads    DAMP  RATE SELECT     Bottom    line shows current value     4  Press the AorW keys until Bottom line shows damp    the desire damp rate is rate settings in seconds   displayed on the bottom line     5  Press the PRGM key  Top line reads    PROGRAM  MODE     Bottom line reads     UNITS SELECT        6  Press the Wkey  Bottom line reads    EXIT        7  Press the PRGM key  Returns to Measure Mode        17 of 32    User Info Select    The User Info Select registers are designed to provide the user with  information on the hardware and software in the manometer  This  register provides read only information on the sensor   s serial  number  software version and date of manufacture  
27. model changes  whenever an improvement is possible   This affords our customers the latest in technology and engineering    OMEGA is a registered trademark of OMEGA ENGINEERING  INC       Copyright 2010 OMEGA ENGINEERING  INC  All rights reserved  This document may not be copied  photocopied   reproduced  translated  or reduced to any electronic medium or machine readable form  in whole or in part  without  the prior written consent of OMEGA ENGINEERING  INC     Where Do   Find Everything   Need for  Process Measurement and Control   OMEGA   Of Course    Shop online at omega com      TEMPERATURE    l4 Thermocouple  RTD  amp  Thermistor Probes  Connectors  Panels  amp  Assemblies  l4 Wire  Thermocouple  RTD  amp  Thermistor    4 Calibrators  amp  Ice Point References   lA Recorders  Controllers  amp  Process Monitors   LY Infrared Pyrometers    PRESSURE  STRAIN AND FORCE    MA Transducers  amp  Strain Gages  LF Load Cells  amp  Pressure Gages  MH Displacement Transducers    4 Instrumentation  amp  Accessories    FLOW LEVEL    MA Rotameters  Gas Mass Flowmeters  amp  Flow Computers  WY Air Velocity Indicators   Mi Turbine Paddlewheel Systems   LY Totalizers  amp  Batch Controllers    pH CONDUCTIVITY    LY pH Electrodes  Testers  amp  Accessories   MH Benchtop Laboratory Meters   MH Controllers  Calibrators  Simulators  amp  Pumps  LY Industrial pH  amp  Conductivity Equipment    DATA ACQUISITION    MH Data Acquisition  amp  Engineering Software   MH Communications Based Acquisi
28. must be visible and aligned in the  middle of the manometer case  To secure the cover  torque the  screws clockwise to 1 6 1 8 in lbs  Do not over tighten     32 of 32                WARRANTY DISCLAIMER    OMEGA ENGINEERING  INC  warrants this unit to be free of defects in materials and  workmanship for a period of 13 months from date of purchase  OMEGA   s WARRANTY adds  an additional one  1  month grace period to the normal one  1  year product warranty to  cover handling and shipping time  This ensures that OMEGA   s customers receive maximum  coverage on each product     If the unit malfunctions  it must be returned to the factory for evaluation  OMEGA   s Customer  Service Department will issue an Authorized Return  AR  number immediately upon phone or  written request  Upon examination by OMEGA  if the unit is found to be defective  it will be  repaired or replaced at no charge  OMEGA   s WARRANTY does not apply to defects resulting  from any action of the purchaser  including but not limited to mishandling  improper  interfacing  operation outside of design limits  improper repair  or unauthorized modification   This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows  evidence of having been damaged as a result of excessive corrosion  or current  heat  moisture  or vibration  improper specification  misapplication  misuse or other operating conditions  outside of OMEGA   s control  Components in which wear is not warranted  include but ar
29. n    8  Press the left arrow key  Returns to Measure Mode       26 of 32    RE CALIBRATION    5 Point EDIT       To edit the calibration points for a 5 Point re calibration follow the  steps below    NOTE  If the factory default values are acceptable  skip this  section and proceed to the re calibration 5 Point START  procedure     Keystroke Display    1  With unit OFF  press and  hold the MIN MAX key   turn the unit on using the  ON OFF key  then release  2  Press the PRGM key     3  Press the up down arrow  keys to edit the selected  digit  Use the left right  arrow keys to change the  cursor position  Note  For  0  go directly to step 4     4  Press the right arrow key  while on the right most digit  to proceed     5  Repeat steps 3 and 4 for  CAL POINTS 2  3  4 and 5     6  After editing CAL  POINT 5 press the right  arrow key while on the right  most digit to proceed    7  To perform the 5 point  re cal  press the up arrow  key until START is  displayed on the bottom  line    OR   To exit without  performing the 5 point re   cal press the left arrow key    Top line reads    RE CAL      Bottom line reads    EDIT        Top line reads    CAL POINT  1     Bottom line displays the  cal point value    Bottom line displays the cal  point value  The cursor  flashes at the first position  while the value is changed   then moves to the right  position when the right arrow  key is pressed    Top line reads    CAL POINT  2     Bottom line displays the  cal point value    Top line r
30. neering unit     Top line of display  continuously updates   Bottom line of display data  is ready for editing  the  first digit is blinking        8 of 32    Press the Aor Warrow  key to set the first  digit to 0     Using the UP arrow  key the character  sequence is 0   9       negative      decimal  point  The     sign is  used if your location  is below sea level     When the digit is  correct press the  PRGM key     If an error is made use  the back space t key  to move the cursor  back to the incorrect  digit  Press the UPA  or DOWN Warrow  keys to display the  correct value     Continue this process  until the display reads  as shown at right     Press the PRGM key  to enter the final  digit        Current  xxx xx  Oxx xx INHG    Cursor flashes to the right  of    0        Current  xxx xx  029 50 INHG    Zeroing is complete when  unit returns to Measure  Mode        Note that the User Adjusted Zero feature will not accept  entries in altitude units  FEET or METERS   When the current  engineering unit is FEET  the User Adjusted Zero function  will automatically prompt for an entry in Inches of Mercury    0   C  When the current engineering unit is METERS  the User  Adjusted Zero function will automatically prompt for an entry  in Millimeters of Mercury   0  C     9 of 32    3  Program Mode    The program mode is used to configure the manometer for  Measure Mode operation  After the PRGM key is pressed in  Measure Mode  the top line of the display reads    PROGRAM  MODE 
31. om line reads     UNITS SELECT        Top line reads    VALUE    00000000     Bottom line reads     CHANGE   YES       Top line reads    USER MODE   FEET     Bottom line reads  00000000        Top line reads    USER MODE   FEET     Bottom line reads     60000000        Cursor flashes to the right of  the    6     Example     60000000           13 of 32    11  Continue the process Top line reads    USER MODE   until the display reads as FEET     Bottom line reads  shown at right     685 0000        12  Press the PRGM key Top line reads    PROGRAM  to enter the final value  MODE     Bottom line reads     UNITS SELECT        13  Press the 4 key to Top line reads    altitude  return to Measure Mode    referenced to 685     Bottom line  reads    U 685 FEET           To set the unit to read in meters  select METERS from the UNITS  SELECT menu  Then follow the same steps as outlined above     Because the local barometer varies with weather conditions  the  USER DEFINED ALTITUDE must be reentered each time the  HHP360 is to be used in this mode  To adjust the unit to the  current barometric pressure without changing the base altitude   select    NO    in step 6 in the table above by pressing the PRGM  key  The HHP360 will display the current altitude referenced to  prevailing local barometric pressure  To maximize accuracy the  local altitude should be reset whenever better altitude information  is available     14 of 32    Pressure Corrected to Sea Level       Pressure reduction to 
32. or misused in  any way  OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER  language  and  additionally  purchaser will indemnify OMEGA and hold OMEGA harmless from  any liability or damage whatsoever arising out of the use of the Product s  in such a manner     RETURN REQUESTS INQUIRIES   Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department   BEFORE RETURNING ANY PRODUCT S  TO OMEGA  PURCHASER MUST OBTAIN AN  AUTHORIZED RETURN  AR  NUMBER FROM OMEGA   S CUSTOMER SERVICE DEPARTMENT   IN ORDER TO AVOID PROCESSING DELAYS   The assigned AR number should then be  marked on the outside of the return package and on any correspondence    The purchaser is responsible for shipping charges  freight  insurance and proper packaging to  prevent breakage in transit           FOR WARRANTY RETURNS  please have FOR NON WARRANTY REPAIRS  consult  the following information available BEFORE OMEGA for current repair charges  Have the  contacting OMEGA  following information available BEFORE  1  Purchase Order number under which contacting OMEGA   the product was PURCHASED  1  Purchase Order number to cover the  2  Model and serial number of the product COST of the repair   under warranty  and 2  Model and serial number of theproduct  and  3  Repair instructions and or specific 3  Repair instructions and or specific problems  problems relative to the product  relative to the product     OMEGA s policy is to make running changes  not 
33. ressure in this condition  All four batteries  should be replaced     To replace the battery locate the battery compartment at the bottom  rear of the manometer  as shown here        Remove the two screws on either side of the battery cover by  turning them counterclockwise until the fully disengaged from the  manometer base  Lift the cover from the back of the unit     Remove the batteries by pulling the positive side first straight out    31 of 32    of the battery compartment  Note the positive     and negative      battery polarity markings at the bottom of the compartment  as  shown here        To install the four batteries  1  Make sure polarity of battery  matches the markings in the compartment  2  Ist place the     end  of the battery into the bottom of the battery slot  3  Then push in      end of the battery until it is seated in the bottom of the battery  slot  The battery compartment has stand offs molded into the side  of the compartment  When a battery is installed with the polarity  reversed  the stand offs prevent the negative battery terminal from  contacting the positive terminal in the battery compartment  The  unit will not power up when a battery is installed this way  Should  this happen  simply reverse the battery to align the polarity     With the batteries secured in the battery compartment  replace the  compartment cover  The cover has only one correct alignment   The    WARNING DO NOT OPEN IN EXPLOSIVE ATMOSPHERE     statement on the battery cover 
34. the PRGM key  Top line reads    RECORD   MODE     and bottom line   reads    AUTO    or      MANUAL       5  Press the PRGM key at Top line reads   AUTO to start automatic    RECORDING X    and   logging or at MANUAL to bottom line reads    XX XX   start manual logging mode  UNITS     AUTO records  value every 5 seconds   Manual records value each  time PRGM key is pressed    6  To stop recording values Top line reads    DATA   at any time  press the qkey    LOGGING    and bottom line  reads    RECORD        7  To access recorded Top line reads    DATA  values  press the A key  LOGGING    and bottom line  reads    VIEW        8  To view recorded values    Top line reads    DATA LOG    press the PRGM key  1    and bottom line displays  the value  Continue pressing  the Akey to view all values     9  Press the q key 3 times    Returns to Measure Mode     The    Auto Shut Off    timer is disabled for Data Logging sessions   Be sure to end the session to re enable the Auto Shut Off timer           23 of 32    Leak Test    The Leak Test feature allows the user to determine the leak rate in  the pneumatic system being monitored  Once configured  Leak  Test monitors the measured pressure over time and displays the  leak rate in the pressure units per minute at the conclusion of the  test  The maximum configurable leak test period is 1440 min  1  day   Pressing any key during the leak test will abort the test     To enable Leak Test follow these steps     Keystroke Display    1  From
35. tion Systems  WY Plug in Cards for Apple  IBM  amp  Compatibles  MH Data Logging Systems   lA Recorders  Printers  amp  Plotters    HEATERS    L7 Heating Cable   WY Cartridge  amp  Strip Heaters  MH Immersion  amp  Band Heaters  WY Flexible Heaters   MH Laboratory Heaters    ENVIRONMENTAL  MONITORING AND CONTROL    MH Metering  amp  Control Instrumentation   LY Refractometers   MH Pumps  amp  Tubing   lA Air  Soil  amp  Water Monitors   LY Industrial Water  amp  Wastewater Treatment   L7 pH  Conductivity  amp  Dissolved Oxygen Instruments          M4928 0610  Manual 9R68M IR EO 6816 Jun  2010    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
e Electro Industries/Gauge Tech Doc # E145703 V1.07 Q-1  Double Usage - Honda Canada    住宅用火災警報器を設置しましょう  訂正書    Nathalie Le Luel (Art moderne)  User Manual – NTP Software File Reporter v7.5_Sept2015_4395EF  Groupe de production SES – Orléans-Tours 1    Copyright © All rights reserved. 
   Failed to retrieve file