Home

Atlas Gold Series Diesel Locomotive User Manual

image

Contents

1. While the locomotive is moving flip the direction switch to turn on the horn Flip the direction switch back to shut off the horn If your locomotive has ditch lights these ditch lights will flash alternately for as long as the horn is blowing and will continue this alternate flashing for a short time afterwards The locomotive will not change direction when you blow the horn Note If you flip the direction switch too slowly from one position to the other you can momentarily lose track power when the switch is being moved through its center position e Ringing the Bell on DC You can turn the bell on and leave it on while you operate other functions on the locomotive Turn the bell on with a Quick flip and back operation of the direction switch Turn the bell off with a second Quick flip and back operation of the direction switch The bell will stay on until you do another Quick flip and back operation of the direction switch to turn it off or if you interrupt the track power Note When you turn the bell off it will continue ringing briefly with less and less volume as the pneumatic clapper slows down just like the prototype 1 See Locomotive Inertia Effects on page 9 for further description of this feature The inertial effects that occur with Regulated Throttle Control RTC can be eliminated by programming your locomotive to use Standard Throttle Control STC Atlas Gold Series Quantum Titan Diesel Locomo
2. Set the direction switch to run your locomotive forward Turn the throttle up slowly until you hear the Quantum System come on You will have to turn the throttle to a higher setting than you would to start a non sound locomotive You will hear Start Up sounds and the front and rear headlights will come on in their dim states Continue to turn up the throttle voltage until the locomotive starts to move in forward The directional front headlight will turn from dim to bright and if so equipped the ditch lights will come on or the Mars Light will start pulsing The locomotive will start out slowly due to special Quantum inertia effects that resist rapid increases or decreases in speed As you slow the locomotive down by gradually reducing the throttle squealing brake sounds will occur while the locomotive comes to a stop e Reversing the Locomotive on DC This simple operation is done in exactly the same manner as with standard locomotives Bring the locomotive to a stop and turn the power all the way off Flip the direction switch and reapply power to go in the opposite direction The rear headlight turns from dim to bright The front headlight will switch from bright to dim f so equipped the front ditch lights will turn off or the Mars light will stop pulsing and switch to dim e Blowing the Horn on DC Blow the authentic diesel locomotive horn for short or long blasts you control the duration
3. A 2 3 Table of Contents Introductio esne e e a a e aaa a e aaa Lie aE 7 New Features Available with the Quantum Titan Sound DeCOdE ccceceeeeeeeneeeeneeeeeeeeeeeeeeeeeeseaeeeeneeseaeeteneees 8 Anado FOAUULOS Saa E E sasabe dh adhd iedeegain gs teangeetvah ata 9 3 1 Starting the LOCOMOUVE sssr anisa inaona arena adenina sain aAa aaa aAa Aena SAATE AA ara Aaa aaen Ia EARRA SEa 9 3 2 DopplerEneCt stn n T sates ita tee a T E N T a a A 10 3 3 Special Horn Ending Sound Optional feature not present in all IOCOMOTIVES ccccceesteeeeesteeeeeeeteeeeees 10 3 4 Operation ini Neutrals ai iene es Ree AN Aachen nbn eee eae Dei 10 3 5 Changing the Locomotive s Direction without Turning off the SOUNG c cccccssceeesesneeeesssneeeesenteeeesseeeeeess 11 3 6 Standard Throttle Control STC and Regulated Throttle Control RTO eccceeseeeseeeeeeeeeeeeeeeeees 11 3 7 ENG ING OaG scoterct tice voetnah eects times Sette tah Att see dh tee T Gath te tte eee death eck tet ie 12 3 8 Sound OF Power Mie eerste aei e aaee aeae eaa telah ra a eaae balers aa ara aaa aae eaa aariaa adra eaea 12 3 9 Helpers ni a a op dads A a a eevee da A a ee eee 12 3 10 Normal and Reversed Direction 0 c cece eeeneeeeeeeneeeeeeeaeeeeeeeaeeeeeeeaeeeeeeeaeeeesecaeeeeeeaaeeeeeeaeeeesseeeeeeeeneeeeeeaas 12 3 11 Fuel Loading Water Loading and Maintenance Scenarios cccccccccsseceessneeeeeseneeeeeseneeeesseneeeeessnseeeessaes 1
4. Table 3 Directional Lighting Operation in DCC and Analog w o Ditch or Mars Light Option Light Forward Neutral from Forward Reverse Neutral from Reverse Front Headlight On Dim Dim Dim Rear Headlight Dim Dim On Dim Table 4 Directional Lighting Operation in DCC and Analog with Ditch or Mars Light Option Light Forward Neutral from Forward Reverse Neutral from Reverse Front Headlight On Dim Dim Dim Rear Headlight Dim Dim On Dim Mars Light Pulsing Dim Dim Dim Ditch Lights On or flashing Off Off Off 4 1 2 Bell F1 Key Pressing the F1 key and releasing it will cause the bell to come on and stay on until you press F1 again There is no difference in operation between the bell button and its corresponding Function Key F1 4 1 3 Horn F2 Key Some DCC throttles have separate horn and bell buttons along with the normal Function Keys assigned to Horn F2 and Bell F1 operation The horn is usually assigned to Function F2 The F2 key behaves differently from the horn button e Pressing the F2 key and releasing it will cause the horn to come on and stay on until you press F2 again e Pressing the horn button will blow the horn only as long as you are holding the button down 4 1 4 Coupler and Coupler Crash Sounds F3 Key There are two ways to use the F3 key As your locomotive is about to couple up to a string of cars press the F3 key to trigger the crashing sound of loc
5. double press F9 F10 Status Report speed in SMPH Status Report Loco DCC address etc F11 Alternate Horn Selection Titan only or Alternate Horn Selection Titan only or Number Board or Marker Lights On Off Number Board or Marker Lights On Off F12 Automatic Cab Lights On Off Automatic Cab Lights On Off F13 System Volume Decrease Titan only System Volume Decrease Titan only F14 System Volume Increase Titan only System Volume Increase Titan only F15 Grade Crossing Titan only F26 Fuel Loading Scenario Titan only F27 Maintenance Scenario Titan only F28 Water Loading Scenario Titan only i Depending on the DCC system the FL Key may be labeled in various ways such as F0 Headlights Lights or Directional Lighting 2 EL f and FL r activate deactivate the automatic behavior of the Headlight Reverse Light and Hazard Directional Lighting regardless of which direction the train is moving Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 18 39 18 June 2012 4 1 1 Directional Lighting Operation F0 FL or Headlight Key The FL or FO or Headlight DCC function key turns on or off the directional front headlight rear headlight and the optional Ditch Lights or the Mars Light The defaults for the front headlight rear headlight and the Ditch or Mars Directional Lights are off When toggled on the Directional Lights come on according to the tables below
6. Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 20 39 18 June 2012 4 1 10 Squealing Brake and Flange Sounds F7 Key Quantum provides automatic brake squeal as a locomotive slows to a stop The operator can also control squealing sounds for continuous and variable brake sounds for protracted stops or to simulate the sounds of squealing wheel flanges on curved track Squealing Brakes come on automatically when the speed is reduced from high speed travel over 40 smph to a speed less than 20 smph Pressing the F7 key when the locomotive is moving at any speed will manually activate Squealing Brake sounds and repeated pressings while the Squealing Brake sounds are occurring will continue the sounds uninterrupted Note If you slow the locomotive too quickly the brake sounds will terminate abruptly when the locomotive stops and enters neutral Note f you lower your throttle to speed step 0 on a moving locomotive the F7 key will apply Air Brakes as long as the locomotive continues moving See the next section 4 1 11 Air Brakes F7 Key Quantum provides automatic brake squeal as a locomotive slows to a stop If you have selected any non zero deceleration inertia or momentum value in CV4 and or CV24 the F7 key can be used to apply brakes to stop the locomotive more quickly than it would normally stop from the inertia settings To use Air Brakes e Turn the throttle down to speed step 0 on a moving locomotive this enables the F7 k
7. sufficient power to the program track to program sound equipped locomotives This comment applies not just to Atlas Gold Series locomotives with QSI sound decoders but also to almost all sound equipped locomotives with any manufacturer s sound decoder However since there are a few DCC systems that do provide enough power to the program track to program sound equipped locomotives in Service Mode Atlas recommends that you first try to program your Gold Series locomotive in Service mode If it works you don t need to do anything If it does not you have three choices e Check with the manufacturer of your DCC system some companies will give you a free upgrade e Install a program track booster NOT the same as a standard DCC system booster between the program track output of your DCC system and your program track See Section 6 3 Program Track Operation e Program on the main line in Operations Mode Ops Mode This third choice is often the best one especially because of the verbal announcement features of QSI sound decoders See Sections 4 2 9 and 4 2 10 4 2 1 Changing the System Volume Electronically CV51 0 You can change the volume either manually as described in Section 6 1 2 Special Operation and Troubleshooting or electronically using QSI CV51 0 in DCC To change the volume in Service or Operations Mode do the following e Set CV49 to 0 e Enter the desired System Volume in CV51 The System Volume can be set to any value bet
8. QSI is a registered trademark of QSindustries Inc Quantum Quantum System Sound of Power Scale Sound Regulated Throttle Control QARC are trademarks of QSindustries Inc MRC is a trademark of Model Rectifier Corporation All other trademarks are the property of their respective holders QSI makes no representations or warranties with respect to this publication In no event shall QSindustries Inc be liable for any damages direct or incidental arising out of or related to the use of this publication Issued 6 2012 Atlas Model Railroad Company Inc 378 Florence Ave Hillside NJ 07205 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 39 39 18 June 2012
9. behaviors As of this writing the current version of this document is Version 5 0 2 You can download the document from the QSI Solutions webpage http www qsisolutions com by first selecting DOWNLOADS amp MANUALS Then go ALMOST to the bottom of the list of downloadable programs and manuals Under the heading General double click on Full DCC Reference Manual for All QSI Decoders Road Map to the Rest of this Document Section 2 is optional It describes the new features available with the Quantum Titan sound decoder If your Gold Series locomotive is running on conventional DC power you should read Section 3 Analog Features of this manual If your Gold Series locomotive is running on DCC you should read Section 4 DCC Features of this manual Section 5 Quantum System Sounds is optional but useful for both DC users and DCC users Finally Section 6 Special Operation and Troubleshooting should be read by both DC users and DCC users 4 A Configuration Variable CV is a memory location in the sound decoder whose value can be changed in order to alter the behavior of the locomotive Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 7 39 18 June 2012 2 New Features Available with the Quantum Titan Sound Decoder Congratulations on purchasing an Atlas Gold Series sound equipped locomotive that is equipped with the QSI Quantum Titan sound decoder the most feature packed and technologically advanced sound decode
10. by clicking on DOWNLOADS AND MANUALS going to the bottom of the webpage and double clicking on the first bullet item under the General heading On the webpage the document is under the heading Full DCC Reference Manual for All QSI Decoders 5 Quantum System Sounds Air Brakes When prototype train brakes are applied air is released from the brake lines to reduce the pressure The more the pressure is reduced the greater the braking You will hear a continual air release sound from the model locomotive as braking is continually increased The longer the air is released the quicker the model locomotive will slow down Once all the pressure is released the locomotive will continue at maximum braking which can still result in along stopping distance depending on your momentum load settings DCC and QARC Only Air Pumps When a locomotive is sitting still the pumps come on in a steady beat to replace the air lost from the brake air release or any other air operated appliances Once the pressure is up the pumps run only occasionally to maintain the pressure Diesel Air Pumps are operated directly from the engine and are quite noticeable when turned on in a non moving locomotive In Forward you will hear the air pumps come on soon after the horn is operated to maintain the air pressure Appliance Air Release Compressed air is used on locomotives for operating various appliances You will hear either a short air release or lo
11. called the Program Track In DCC terminology programming locomotives on the Program Track is called Service Mode Programming e Anywhere on your layout trackage In DCC terminology programming a locomotive on your layout is called either Programming on the Main POM or Operations Mode Ops Mode Programming Many DCC systems cannot supply enough power to the program track to read and write the CVs of sound equipped locomotives This problem may normally be solved by installing a Program Track Booster between the program track output of your DCC system and the program track See Section 6 3 However Atlas recommends that you use Operations Mode Ops Mode programming to change the address of your Gold Series locomotive provided that your DCC system allows you to program 4 digit addresses on the main line most DCC systems do The following table shows some DCC systems commonly sold in North America that do and do not support direct 4 digit address programming on the main line For those relatively few DCC systems that do NOT support Ops Mode address programming a reference is given to one of three alternate programming procedures defined later in this section For all other DCC systems use the programming procedure in Section 4 2 8 1 43 STC and RTC operate in a similar fashion in Analog and in DCC 44 Consult the Quantum Titan DCC Reference Manual Version 5 0 2 to learn how to reset different groups of CV s 45 413 is QSI s Ma
12. can be programmed using a standard variable DC power pack After entering programming described below the various features are selected and operated by using the direction switch e Use a Quantum Engineer controller connected between your variable DC power pack and your layout The Quantum Engineer considerably simplifies the programming process The table on the next page lists the available analog programming options The sections that follow 3 13 1 to 3 13 4 explain the basics of analog programming using the reversing switch on a DC power pack Some specific examples are included after Section 3 13 4 For further information on using the Quantum Engineer controller for analog programming see the Quantum Engineer Operating Manual Ver 2 0 on the QSI web site at htto www qsindustries com Important Because of the higher current draw of O scale locomotives you MUST add a Quantum Engineer Booster available from Tony s Train Exchange and other retailers between your O scale variable DC power pack and your 2 rail O scale layout Be sure to wire the Quantum Engineer and Quantum Engineer Booster exactly as shown in the instructions that come with the Quantum Engineer Booster Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 14 39 18 June 2012 Table 1 Analog Programming Options Program Option Name Message when Option Descr
13. moving in forward or in reverse After you have selected a locomotive on your DCC system simply press any of the function keys listed below to produce the sound or other effects described in the table below Those features marked Titan only are available only in Atlas locomotives that are equipped with QSI Titan sound decoders All other features are available in Atlas locomotives with either Titan or earlier QS sound decoders Table 2 DCC Function Keys Function Key Forward or Reverse FWD or REV Neutral either NFF or NFR FL Headlight Rear Headlight and Hazard Headlight Rear Headlight and Hazard Light Light directional lighting On or Off directional lighting On or Off FL n Headlight Rear Headlight and Hazard Headlight Rear Headlight and Hazard Light Light directional lighting On or Off directional lighting On or Off F1 Bell on off Bell on off F2 Horn or horn with Doppler Effect see Horn Section 4 1 8 F3 Coupler Crash Coupler Fire Coupler Arm Enable or Coupler Fire F4 Diesel Fans and Louvers Diesel Fans and Louvers F5 Dynamic Brake function On Off Dynamic Brake function On Off in Disconnect only F6 Doppler Shift Locomotive Start Up double press F6 F7 Squealing Brakes Flanges and Air Brakes Diesel Long Air Let off F8 Audio Mute Audio Mute F9 Heavy Load On Off Change Shut Down State Disconnect Standby Total Shut Down
14. on in Analog without the need for blocks You can place locomotives on sidings and shut them off without having to switch power off in that track section You can make up consists by bringing up each locomotive one at a time After you couple each locomotive to the consist shut it down with the Magnetic Wand When all locomotives are in place select each locomotive in turn with the Magnetic Wand until all locomotives are running You can now operate the consist as a single unit When you break up the consist you first deselect all locomotives one at time and then select each one in turn as you disconnect and pull away from the consist 6 2 High Voltage Circuit Breaker Analog and DCC Your locomotive is designed to operate on the normal DC track voltage supplied by most variable DC power packs and DCC systems If the track voltage exceeds 21 5 volts peak the motor drive circuit will automatically shut down and the locomotive will coast to a stop The Quantum System alerts you to the problem through a continuous series of horn hoots This built in safety feature protects both the Quantum electronics and the motor from excessive voltage To restart your locomotive reduce the track voltage until the hooting stops and the motors re engage 52 The wand does not need to touch the body It can be held a reasonable distance from the top of the locomotive to prevent possible marring of the painted surface 53 The high voltage circuit breaker will
15. the Main Line for CVP Products EasyDCC System 31 4 2 9 Disable Enable Verbal Announcements CV62 cccccccccseeeeeeeeeeneeeeeeeeseaeeseaeeeseaeeseeaeeseaeeseaeeeteaeeseneeeeeaeens 32 4 2 10 CV Inquiry with Verbal Feedback in Ops Mode CV64 cceecceeeeeeeeeeeeeeeeeeeaeeeeeeeeseaeeseaeeeseaeeseneeeteaeess 32 4 2 11 Selecting a Value for CV2 9i e cine odes ines eave a ee ede eae i ia 32 Quantum System SOUNAS cceccceccceseceseeeseeeeeeceeecececaeceaeseaeecaeecacecaaeeaeceaeseaeecaeeseeesaeseaeeeaeseaeeseeesieeseaeeeaeeeaeeseeeas 33 Special Operation and Troubleshooting cccccecececeeeeeeeeeeeeeeeceeeeeceeeeseaeeseaeeesaeeseaeeesaeeseeeeseaeescaeeeseaeeseueeeseeeeeaas 34 6 1 Reed Switch Operation with the Magnetic Wand Analog and DCC 0 cccecceseeeeeeeeeeeeeeseeeeeeaeeseueeeseneesaas 34 6 1 1 Resetting your Locomotive to Factory Default Values Using the Magnetic Wand resets all Analog and all DGCiparameters ve csccve eae ees esate ee ease oie eee alee ee ie es tee ot ne Cee ote cea 35 6 1 2 Manual Volume Adjustment Analog and DCC ecccecccceceeeeeeneeeseaeeeeseeeeneeseaeeeeaeeseaeeseaeeeseaeeseeaeeseaeesaas 36 6 1 3 Turn your Locomotive Off or On using the Magnetic Wand Analog Only c ccceeeeeeeeeeeeeeeeeteeeeeeetens 36 6 2 High Voltage Circuit Breaker Analog And DCC ccccscecesceeeeeeeeeeeeeeeeeceaeeeeaeeeseaeeseaeeeseaeeseaeeeseaeeseueeeseaeesaas 36 6 3 Program Track Operati
16. the word reset spoken from the locomotive 7 Caution if you don t hear the word reset spoken your locomotive has NOT been reset 8 Pull the Magnetic Wand straight up away from the locomotive immediately after you hear reset so that the manual volume adjustment procedure is not activated This procedure works ONLY with those QSI equipped locomotives that have a magnetic reed switch Although all Gold Series Atlas HO and Gold Series Atlas O 2 rail locomotives have a magnetic reed switch some QSl equipped locomotives from other manufacturers have a jumper wire instead of a reed switch If your locomotive has a jumper wire to trigger reset refer to the manual included with your locomotive for reset instructions Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 35 39 18 June 2012 6 1 2 Manual Volume Adjustment Analog and DCC Locate the reed relay area on the top of the locomotive as shown in the photograph on page 3 of the 4 page locomotive information booklet that is included with your model 2 Power up the locomotive and leave it in Neutral Make sure that the bell is not turned on 3 Place the silver part of the enclosed magnetic wand over the reed switch area on the top of the locomotive parallel to the ties and perpendicular to the rails and wait as you hear the volume increase or decrease in incremental amounts as the horn hoots about every second Move the wand away and again place it over the r
17. your DCC system has only an F2 button this button may be set at the factory for either latching or momentary operation depending on the DCC system Some DCC systems allow the user to choose between latching or momentary operation of a function key If your locomotive has ditch lights these ditch lights will flash alternately for as long as the horn is blowing and will continue this alternate flashing for a short time afterwards 2 Not all Atlas sound equipped locomotive models have the Ditch Lights or Mars Light feature 3 Neutral sounds also include cooling fans with vents opening and closing that turn on and off randomly Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 3 39 18 June 2012 e Ringing the Bell on DCC You can turn the bell on and leave it on while you operate other functions on the locomotive Turn the bell on by pressing the Bell or F1 key on your DCC throttle The bell will stay on until you do another press of the Bell or F1 key on your DCC throttle or if you interrupt the track power Turn the bell off with a second press of the Bell or F1 key on your DCC throttle Note When you turn the bell off it will continue ringing briefly with less and less volume as the pneumatic clapper slows down just like the prototype Programming a New DCC Address for Your Locomotive The decoder in an Atlas Gold Series locomotive comes from the factory set to use the short address 3 However in order to con
18. 15 Status F10 Key The Quantum Titan system installed in Atlas sound equipped locomotives provides verbal information about the locomotive s current operating state when the locomotive is in neutral or about the locomotive s current speed in scale miles per hour when the locomotive is moving If you press the F10 key in Neutral the locomotive will verbally report first its currently enabled long or short DCC address followed by its consist ID if it has one followed by its shut down state Disconnect Standby or Shut Down if any Press the F10 key in Forward or Reverse the locomotive will verbally report the locomotive s speed in scale miles per hour Note When Status Report is activated the locomotive s sounds will reduce to one half their current volume settings during the verbal report and then return to normal volume when the report has ended 4 1 16 Alternate Horn Selection F11 Key Some prototype diesel locomotives had two different air horns The first horn worked best in areas where it was necessary for the sound to carry a long way while the other horn was more useful in the city or fogy areas where it was easier to tell the location of the locomotive by its higher pitched sound The Alternate Horn Selection key allows you to choose between two different Horn sounds To use this feature e Press the Alternate Horn Selection key F11 to select between the alternate Horn and the primary Horn Hear a short hoot to indicate whi
19. 2 3 11 1 Triggering the Scenarios in DC Operation cccscceceeceeeceeeeeeeeeeeeeeeeeeceneeseaeeseaaeescaeeseeeeseeeeneneeseaeeeas 13 3 11 2 Timing Of Horn BIASAE eiee e Ea a e ES 13 3 12 Additional Analog Operation Features Available with Quantum Engineer Controller ccccccceseeeeeeees 14 3 13 Analog Programming soroan eccc cele ee idane e iea i eden EHN Eri E LAANE E EEA ce La ENORA EEA EO TAAA OERO E TAE A ARE RE aR 14 3 13 1 Entering Analog Programming eesis E EEE ETA 16 3 13 2 Scrolling through the Program Options ccccceceseeeeeeeeeeeeseeeeeeaeeseeeeeaeeseaeeeseaeeseaeeeeaeeeseaeeeeeeeeesaeeseas 16 3 13 3 Entering a Program Option and Making Changes cccccccccceseeeeeseeeeeeeeeeeneeeeeaeeseeeesseaeeseaeeeseaeeseneeseaees 16 3 13 4 Moving on to Other Program Options or Leaving Programming seessseesseessressressresirsrirnsrnnsrrnsrensrensne 16 DCO Features mosie e iie eie aed E iaaa A R a a a a ia iii a a i a a i eiie i 18 4 1 ROSE EBA EA L E E E A EE E A E E T 18 4 1 1 Directional Lighting Operation FO FL or Headlight Key cccccccscceeeeeeeeeeeeeeeeeeeneeeeeeeeeeaeeseeeeseeeeeeaeess 19 AT Bel CR REY ioraa n AA E ar saa fetet O edad i AA oes Ea age eee See eee 19 41 3 ROMPAK en enn eae Ate aes ha elas leis ere 19 4 1 4 Coupler and Coupler Crash Sounds F3 Key cccseececeeeeeeeeeeceeeeeeeeeceaeeseaeeeseaeeseeeeeeaeeseaeeeseaeeeeneeeeeaeess 19 4 1 5 Diesel Fans and Louvers F
20. 4 Key cccesccceeeeeeeeeeeeeneeeeeeneeeeeeeaaeeeeeeaaeeeeseaaeeeeeeaaeeeessaaeeeeeseaeeeeseneeeesesaees 19 AlV65 SOUMG Ol POW I EEEE E AE A A aloes iatiesda E E let vensteaganetas 20 A17 Dynamic Brakes Fa KEVF nroa nan a AAAA TAAA AAIR Aaa A ATERA AAA ASRANG EARN 20 4 1 8 Doppler Effect Operation single press F6 Key ccccccesceceseeeeeeeeceneeeeeeeeeeaeeseeeeeseaeeeeeeeseaeeetsaeeseneeeeeaeess 20 41 9 Start Up double press F6 KEY cissctiviteceee cestetieteebetetovetentysepeoreveetats ceuedebeiritattvateverssieectivinchibelaeinrenacties 20 4 1 10 Squealing Brake and Flange Sounds F7 Key ccccsceceeeeeeeeeeeneeeeeeeeseaeeeeeeeseaeeseeeeseaeeeseaeeseneeeeeaeess 21 4 1 11 Air Brakes F7 Key Vue a aA AT ER aa AA Aon eee adits 21 4 1 12 MUE FE KOV nea O O T ATTAR 21 4 1 13 Heavy Load single press F9 key ccccceeessceeeeeeneeeeeeeneeeeeeeaeeeeeeeaeeeesesaeeeeeeaeeeessaeeeessaeeeeeesaeeeesenaeeeeeeaas 21 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 5 39 18 June 2012 4 1 14 Three Stages of Diesel Locomotive Shut Down 1 Disconnect 2 Standby 3 Total Shut Down double press FI Key si c ecce seed ce ektenetaet at eelccns chistes a a E E a E g cuthee 22 AAAS Status FTO KEY arseenia aae raei aer aaa aa aana ara Oe aa aa ra aa E aa a Aar Ea AEO dapeeuiyseattanas 23 4 1 16 Alternate Horn Selection F11 Key cc cccccsceceeeeeeeeeseeeeeeeeeceeeeceaeeesaeeseaeeseaeeeseaeese
21. Blasts A short horn blast is one of length greater than or equal to 0 2 second but less than 1 8 seconds This is the time you hold the horn button down not necessarily the length of time you hear the horn sound play e Minimum and Maximum Lengths in msec of Long Horn Blasts A long horn blast is one greater or equal to 1 8 seconds but less than 10 0 seconds This is the time you hold the horn button down not necessarily the length of time you hear the horn sound play e Minimum and Maximum Separations in Time in msec between Different Horn Blasts There is no minimum time The maximum time between the start of one horn blast and the start of the next horn blast in a coded horn sequence is 2 1 seconds Also there must be 2 5 seconds of horn off time before the start of a coded horn sequence 14 See Section 3 12 for information on the Quantum Engineer Controller See Section 4 1 14 for an explanation of the Standby state The three Shut Down states Disconnect Standby and Shut Down behave the same way in both DC and DCC Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 13 39 18 June 2012 3 12 Additional Analog Operation Features Available with Quantum Engineer Controller Your Atlas sound equipped diesel locomotive is equipped with QSI s QARC Quantum Analog Remote Control Technology QARC Technology uses special remote control signals to operate different Quantum features on a conventional DC layout With QARC Technolo
22. F9 commands sent within two seconds Note that the F9 key may sometimes have to be pressed three times due to the command station and locomotive having different initial states for F9 Function keys will only produce a short air let off Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 22 39 18 June 2012 fans shutting off the louvers closing the diesel engine shutting down and finally the Cab Lights shutting off A few seconds later you will hear the engineer s door open and then shut In Total Shut Down the locomotive will not respond to the throttle or to the Function keys The two exceptions are the F6 Start Up Function Key described below and the F10 Status Key described below If DCC track power is turned off at any stage of Shut Down Disconnect Standby or Total Shut Down or during a Shut Down procedure the locomotive will remember the last Shut Down stage in which it was prior to power going off and the locomotive will power up in the same stage of Shut Down If Start Up is initiated during any of the above Shut Down procedures Shut Down will be aborted and the locomotive will return to normal operation Note Total Shut Down allows the operator to take the locomotive off line turn off sounds lights ignore throttle settings and function key commands independent of the operating session that is the locomotive will still be off line when power is reapplied for the next operating session 4 1
23. The level of labored sounds is proportional to the values for these four CV s and to how much the DCC throttle is increased or decreased Diesel Engine RPM Quantum has all eight of the diesel engine throttle notches that are found on prototype locomotives As you increase the throttle you will hear the RPM s increase for every increase in ten speed steps at the 128 speed step setting Idle is considered Notch 1 and occurs for speed step 0 Notch 2 ranges from 1 to 10 Notch 3 from 11 to 20 Notch 4 from 21 to 30 etc If your DCC system has an option to increment or decrement your throttle setting by ten speed steps it is very easy and predicable to set your notch value 4 1 7 Dynamic Brakes F5 Key A prototype diesel locomotive usually has Dynamic Brakes that cause the train to slow down by using the traction motors in generator rather than the normal motor mode This technique helps dissipate the energy of a moving train by converting it to electrical power which is then applied to a large air cooled resistor load in the locomotive e Pressing the F5 key in Forward or Reverse will set the locomotive diesel engine sounds to idle at the lowest Sound of Power setting and turn on the powerful Dynamic Brake Cooling Fans e Pressing the F5 key in neutral will turn on the Dynamic Brake Fans while diesel engine sounds remain at idle The Dynamic Brake function automatically turns off when entering or leaving neutral the speed of the locom
24. Throttle Mode Selects between Standard Throttle Control STC and Regulated Throttle Control RTC equals X RTC 11 Programming Reset Warning about to After next Quick or Slow Operation three bell rings followed by a spoken Reset to reset indicate locomotive returned to factory default parameter values 12 About Model number Each Quick or Slow Operation provides progressive information about Quantum software model number software version and software release date 13 Horn Volume Volume equals X Customizes Horn Volume 16 levels Max is 15 14 Bell Volume Volume equals X Customizes Bell Volume 16 levels Max is 15 15 Engine Volume Volume equals X Customizes diesel Engine Volume 16 levels Max is 15 16 Vents and Cooling Fan Volume equals X Customizes Vents and Cooling Fans Volume 16 levels Max is 15 Volume 17 Turbo Volume Volume equals X Customizes Turbo Volume 16 levels Max is 15 17 19 Reserved Reserved 20 Air Brakes Volume Volume equals X Customizes Air Brake Air Release Volume 16 levels Max is 15 21 25 Reserved Reserved 26 Pump Volume Volume equals X Customizes Air Pump Volume 16 levels Max is 15 27 Air Let off Volume Volume equals X Customizes Long Air Release Volume 16 levels Max is 15 28 Short Air Let off Volume Volume equals X Customizes Short Air Let off Volume 16 levels Max is 15 29 Reserved Reserved 30 Flange Volume Vo
25. USER S MANUAL Atlas Gold Series Diesel Locomotive User Manual For Atlas Diesel Locomotives Equipped with a QSI Quantum Titan Sound Decoder 18 June 2012 Atlas Manual Version 6 0 For Quantum Firmware Version 8 Atlas Gold Series Quantum Titan Diesel Locomotive User Manua 1 39 18 June 2012 Quick Start Guide to Atlas Gold Series Locomotives Congratulations on purchasing an Atlas HO scale or 2 rail O scale Gold Series sound equipped locomotive that is equipped with the QSI Quantum Titan system the most feature packed and technologically advanced sound decoder available today The information in this section is designed to get you running your new Gold Series Titan locomotive as quickly as possible whether you are using conventional DC or DCC Atlas recommends that you get used to operating and having fun with your new Atlas sound equipped diesel locomotive before exploring its more advanced features and programming options The following two sections describe how to operate your locomotive on a DC powered and on a DCC powered layout respectively Regardless of whether you are using DC or DCC you will be up and running with your new locomotive in fewer than five minutes Analog DC Operation Quick Start Read through this section and be up and running with your new locomotive on a DC layout in fewer than five minutes e Running the Locomotive on DC Use a variable DC power pack with a standard direction switch
26. able below do the following steps e Set CV49 to the Primary Index for the individual sound whose volume you wish to change from the table below e Enter the desired Volume level in CV52 as follows 0 No sound 1 15 sets volume from the lowest level at 1 to the highest at 15 with the volume levels changing in 2 dB increments Note Normally the default volume level for each type of sound is 11 Table 6 Using an Indexed CV to Change the Volume of an Individual Sound Horn Volume o 0 15 52 0 0 Minimum Volume 15 Maximum Volume Bell Volume 8 0 15 52 8 0 Minimum Volume 15 Maximum Volume Diesel engine Volume 10 0 15 52 10 0 Minimum Volume 15 Maximum Volume Diesel engine 2 Volume 11 0 15 52 11 0 Minimum Volume 15 Maximum Volume Turbocharger Volume 14 0 15 52 14 0 Minimum Volume 15 Maximum Volume Air Pump Volume 16 0 15 52 16 0 Minimum Volume 15 Maximum Volume Cooling Fans Volume 19 0 15 52 19 0 Minimum Volume 15 Maximum Volume Long Air Let off Volume 21 0 15 52 21 0 Minimum Volume 15 Maximum Volume Short Air Let off Volume 22 0 15 52 22 0 Minimum Volume 15 Maximum Volume Squealing Brakes Volume 24 0 15 52 24 0 Minimum Volume 15 Maximum Volume Generator Volume 26 0 15 52 26 0 Minimum Volume 15 Maximum Volume Dynamic Brakes Fan Volume 28 0 15 52 28 0 Minimum Volume 15 Maximum Volume Splitter Valv
27. about three seconds later These sounds will be followed by air pumps and other background sounds In addition to the pumps in neutral cooling fans and vents will switch on and off at random time intervals After ten seconds the cooling fans shut off if they were on when you entered neutral Cab Lights come on 10 seconds after entering neutral If the diesel locomotive is left in Neutral From Reverse a special Low Idle State which is marked by subdued throbbing engine sounds will automatically come on after 30 seconds See description of Low Idle in Section 5 Quantum System Sounds The diesel locomotive will return to normal diesel sounds when the throttle is turned up After the pumps start you can use the direction switch to blow the horn or turn on or off the bell If you cannot enter neutral or have difficulties with any of these operations you may need to program your locomotive for optimal use with your particular power pack See Analog Programming Section 3 13 If Regulated Throttle Control is enabled see below it is important to wait until the locomotive stops on its own The engine s electronic inertia will keep it moving even though you have reduced the throttle far enough below V Start to stop the locomotive In your attempt to stop the locomotive do not try to reduce the throttle so far that all sounds go off In neutral the bell has a distinctive turn on effect as the pneumatic clapper gains full motion to strike th
28. ackground sounds The directional front headlight will go dim If your Atlas sound equipped locomotive has ditch lights the ditch lights will turn off in neutral Similarly if your Atlas locomotive has a Mars Light this Mars light will stop pulsing and go dim and the front headlight will go dim e Reversing the Locomotive on DCC This simple operation is done in exactly the same manner as it is with standard locomotives The direction of your locomotive will change when you press the direction button on your DCC throttle The directional headlights behave as follows e When the locomotive is moving forward the front headlight will be bright when the locomotive is stopped or moving backwards the front headlight will be dim e When the locomotive is moving backwards the rear headlight will be bright when the locomotive is stopped or moving forward the rear headlight will be dim e Blowing the Horn on DCC Blow the authentic diesel locomotive horn for short or long blasts you control the duration The operation of the horn depends on how your DCC system was designed and configured If your DCC system has separate Horn and F2 buttons e Pressing the Horn button will blow the horn only for as long as you are holding the button down This behavior is called momentary operation e Pressing the F2 button and releasing it will cause the horn to come on and stay on until you press F2 again This behavior is called atching operation If
29. aeeeseaeeseaeeeseaeeseaeesas 23 4 1 17 System Volume Decrease F13 Key and Increase F14 Key ccccccsceeeeeeeeeeeeceeeeeeeeeeseaeeeeeeeeeeaeetas 23 4 1 18 Grade Crossing F15 Key in Forward or Reverse cccccceeeeeeeeeeeeeeeeeeeaeeeeeeeseaeeseeeeseaeeseneeeseeeeeeneess 23 4 1 19 Fuel Loading Scenario F26 Key in Neutral cceccceeeeeeeeeeeeeeeeeeeeeeceeeeeeaeeeseaeeseeeeseaeeseaeeeseaeeseneeseaees 24 4 1 20 Maintenance Scenario F27 Key in Neutral ccccscceeeeeeeeeeeseeeeeeeeeeceaeeeeaeeeseaeeseeeeseaeessaeeeseaeeseieeseaees 24 4 1 21 Water Loading Scenario F28 Key in Neutral cccccceceeceeeeeeeeeneeeeeeeeceeeeseaeeseaeeeseaeescaeeeseaeeeseaeessaeensas 24 4 1 22 Function Key Operation in Neutral cccccccceeeceseeeseneeeeeeeeeeeeeseaeeeseaeeseaeeseaeeeseaeesseesseaeeseaeeeseaeessaeeseaees 24 4 1 23 Automatic Features with Take Control Operation cccccececceeeeeeeeeeeeeeeeeeeeeseaeeseeeeeeeaeeeseaeeseeeeeeeaeess 24 4 2 DGG PrOQramimliag s a a T a tuto eee ape aad tote a a a eden hea te aE Lace 25 4 2 1 Changing the System Volume Electronically CV51 0 0 c cececeseeeeeeeeeeeeeeeeeeeeeeeeseaeeeeeeeeeeaeeseeeeseeeeeeaeess 25 4 2 2 Changing the Mute Volume Electronically CV51 1 cccccecesceseneeeeeeeeeeaeeeeeeeseaeeeeeeeseaeeseaeeeseaeeseneeeteaeess 25 4 2 3 Enable Disable Horn Triggered Doppler Shift CV51 2 ceccceceseceseeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeseaeeese
30. aeeseneeeneaeees 25 4 2 4 Enable Disable Automatic Horn Warning Signals CV51 20 c ccecececeeeeeeneeeeneeeseeeseeeeeeeaeeseeeeeeeeseeees 26 4 2 5 Changing Individual Sound Volumes CV52 X cesccceeeeeeeeeeeneeeeeeeeeeaeeeeeeeeseaeeseeeeeseaeeseeesseaeeeseaeeeeneeeeeeeess 27 4 2 6 Selecting Standard Throttle Control or Regulated Throttle Control CV56 4 c cceseeeeeeeteeeeeees 28 4 2 7 Reset All CV s to their Factory Default Values CV56 128 255 cccccecceeeeeeeeeeeeseeeeeeeeeeeeaeeteneeeteteeeeeaeess 28 4 2 8 Programming a New DCC Address for Your Locomotive cc cceeeeeeeeeeeeeeeeeeeeeeseaeeeeeeeeseaeeeteaeeseeeeeteatess 28 4 2 8 1 Special Procedure for Long 4 Digit Address Programming of Gold Series Locomotives on Main Line works with most DCC SySteMS cccsceceneeeeeeeeeeeeeeeaeeeeeaeeeeaeeseaeeeseaeeseaeeeceaeeseaeeesaeeseaeeseeeeseaeeseneeeeeaeess 29 4 2 8 2 Special Procedure for Long 4 Digit Address Programming on Main Line with Digitrax Zephyr or Zephyr xtraiD CG SVStOms eee cosa ctescesavcececaas dh cea vgs oxthacarae nasi esceeael eauict anu t eaten satease av secnesaarcensecastessastavrnnaenetaaet 30 4 2 8 3 Special Procedures for Short or Long Address Programming for Lenz and Other DCC Systems that Do Not Normally Permit Address Programming on Main Line CV56 129 ceeececeeeeeeneeeeeeeeeeeeeseaeeeeeaeeseaeeeeas 31 4 2 8 4 Special Procedures for Long Address Programming on
31. ake to resolve a problem should always be to reset the Quantum Titan sound decoder There are two ways to reset the sound decoder parameters 1 the DCC only reset described in Section 4 2 7 that resets only the DCC CVs and 2 the magnetic wand reset described here that resets both DCC CVs and analog parameters Since a number of parameters e g sound volumes are shared between DC and DCC operation the magnetic wand reset does a better job of resetting the decoder to its original factory configuration Hence Atlas recommends resetting using the magnetic wand whether your locomotive is normally operated on DC or on DCC The following items are needed in order to do a magnetic wand reset ITEMS REQIRED FOR MAGNETIC WAND RESET 1 The Gold Series locomotive that you wish to reset 2 The magnetic wand packed with your locomotive 3 The 4 page locomotive information booklet packed with your locomotive that shows in a photo at the top of page 3 where to place the magnetic wand on the top of your locomotive A section of track longer than your locomotive A power pack with a Variable DC output Wires to connect the power pack to the track Sous Please note that it is essential to use conventional DC track power for this magnetic wand reset procedure to work properly This procedure applies to all Atlas Gold Series locomotives both HO and Two Rail O scale 1 Turn off all track power to your layout 2 Place your Atlas Gold Series so
32. as Gold Series locomotive is currently using a Short 2 digit address or vice versa the following special procedure must be followed with most DCC systems In particular you must use this procedure for address programming on the main line if you have a Digitrax except for Zephyr and Zephyr xtra an MRC Prodigy Advance Advance Wireless or Express or an NCE DCC system Proceed as follows to program a new 4 digit address on the main line 1 Operate the locomotive on the main line using its current DCC address 2 If you cannot determine the DCC address that will run the locomotive transfer the locomotive to a DC powered Track and reset the Quantum System decoder using the magnetic wand Follow the magnetic wand reset procedure described in Section 6 1 1 When doing this reset be sure to increase gradually the DC track voltage from 0 to about 8 volts HO scale or from 0 to about 10 volts O scale After the reset make sure that the locomotive can be operated using the default DCC address 3 3 Disable verbal announcements by using Operations Mode programming to set CV62 0 Consult your DCC system manual for an explanation of how to program CVs Since you have just disabled verbal announcements you will not hear any verbal confirmation of the value of 0 that you wrote into CV62 4 Follow the procedure in your DCC system manual for programming a new address using Operations Mode programming on the main line Since you are pr
33. ce a long air let off Directional Lighting will turn on if previously on the diesel engine sound will change from the special Low Idle to regular Idle and the locomotive will enter normal operation e Start Up from Total Shut Down If you double press the F6 key in Total Shut Down the diesel locomotive will produce a long air let off you will hear the engineer s door opening and closing Cab Lights will come on if available and loco is Normal or Lead Helper Number Boards will come on if available and loco is Normal or Lead Helper Directional Lighting will turn on if it was previously off These actions are followed by sounds of the vents opening the diesel engine starting up the pumps starting up and the locomotive entering normal operation During the Start Up procedure none of the function keys are active If the throttle is turned up from zero during any of the above Start Up procedures the Start Up procedure will abort and the locomotive will enter normal operation Note Whenever a Start Up command is sent regardless of whether the locomotive is in Shut Down or operating normally the Quantum System will automatically restore all Automatic Operations 3 Dynamic Brakes on prototype locomotives are less effective and seldom used at low speeds it you do not turn on either the horn or bell the Doppler shift will still occur but will be less dramatic 32 If the bell was on it will shut off prior to sounds returning to normal
34. ch as http ruppweb dyndns org xray comp decoder htm or else by following the instructions for calculating the values of CV17 and CV18 in the NMRA DCC Reference Manual for QSI Quantum FX Q2 and Q1 Equipped Locomotives Version 5 0 2 or later 2 Make sure that verbal announcements of CV values are turned on CV62 1 3 Using Operations Mode Programming program CV17 to the value that you determined in Step 1 Listen to the value of CV17 that is spoken out by your locomotive If it is correct go to Step 4 if it is incorrect repeat Step 3 4 Using Operations Mode Programming program CV18 to the value that you determined in Step 1 Listen to the value of CV18 that is spoken out by your locomotive If it is correct go to Step 5 if it is incorrect repeat Step 4 5 Using Operations Mode Programming program CV29 to the value 38 Listen to the value of CV18 that is spoken out by your locomotive If it is correct go to Step 6 if it is incorrect repeat Step 5 6 Verify that the address of your locomotive has been changed successfully changed by running it on the main line 46 Entering 38 leaves the other configuration settings in CV29 at factory default values but changes the ID to extended type 47 if you wish to make any other changes to CV29 see Section 4 2 11 for a list of the possible options for CV29 do not do so until you have verified that the address has been changed successfully Atlas Gold Series Quantum Titan D
35. ch horn has been selected e Operate the selected Horn with the F2 key Note The feedback hoots can be disabled or enabled by using CV51 2 See Version 5 0 2 or later of the QSI DCC Reference Manual Note Setting F11 to 1 selects the primary Horn Setting F11 to 0 selects the alternate Horn Note This F11 Alternate Horn Selection feature is currently available only with Quantum Titan sound decoders 4 1 17 System Volume Decrease F13 Key and Increase F14 Key You can decrease the System Volume by 2 dB by pressing the F13 key You can increase the System Volume by 2 dB by pressing the F14 key Each time you press the F13 or F14 key you will hear a horn hoot at the new system volume If the system volume is already at the maximum when you press the F14 key the volume will not increase and the locomotive will speak the word Max Both F13 and F14 are inactive when the locomotive is in shutdown Pressing F13 F14 decreases increases the value of CV51 0 System Volume Note These F13 F14 features are currently available only with Quantum Titan sound decoders 4 1 18 Grade Crossing F15 Key in Forward or Reverse Prototype railroads use horn or whistle codes of long and short blasts for communication or warning signals One of the most common is the code of two longs a short and a long horn signal to warn that the train is approaching a grade crossing Although you can perform these signals with the Horn button the Quantum T
36. ctivate the horn and activating the F6 Doppler Key while this button is held down will cause the horn to shut off instead of causing a Doppler shift effect We have experienced intermittent and independent horn signal interruption with certain DCC systems causing unexpected Doppler shifts If this happens frequently you may want to disable the Horn Triggered Doppler shift CV51 2 see Section 4 2 3 6 1 Reed Switch Operation with the Magnetic Wand Analog and DCC Your Atlas sound equipped locomotive is equipped with a special reed switch located directly underneath the top of the plastic diesel locomotive shell This switch can be activated by the Magnetic Wand enclosed without having to disassemble the locomotive The reed switch can be used either to reset the locomotive parameters to factory defaults or to change the overall volume of your sound system Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 34 39 18 June 2012 6 1 1 Resetting your Locomotive to Factory Default Values Using the Magnetic Wand resets all Analog and all DCC parameters Resetting the firmware in the Titan sound decoder to its factory built configuration can resolve many problems that sometimes occur with firmware controlled electronics In fact at Atlas we have found that at least 20 to 25 percent of the problems with Gold Series locomotives that we receive for repair can be resolved simply by resetting the sound decoder Hence the very first step you t
37. dicating the correct value is being calculated If you chose a very low setting for V start be patient If you do not get a setting within a minute return to the beginning of this option or start over completely this time chose a slightly higher throttle value e Atthe end of the process the locomotive will move slightly and stop The horn will hoot signifying the end of the operation and you will hear the message V Start X where X is the new setting Note The final value of V Start will decrease from the original voltage reading because resistance in the power pack or pickups will drop the voltage slightly during this calibration procedure Note Sometimes it is difficult to see the locomotive move unless you are watching carefully To leave programming turn the throttle off and then power up for normal locomotive operation Alternatively continue to V Max by moving the direction switch and waiting for the next programming option to be announced Example 3 Setting V Max Analog Option 9 V Max is set in the same manner as V Start except after entering this Program Option you will hear Set throttle to V Max which is the position where you want the full track voltage to be applied to the motor usually about 80 of full throttle Then do a Quick or Slow operation to set V Max Note At end of V Max setting the locomotive will not move as it does under V Start Note When double heading your Quantum equipped l
38. e Volume 29 0 15 52 29 0 Minimum Volume 15 Maximum Volume Coupler Volume 34 0 15 52 34 0 Minimum Volume 15 Maximum Volume Air Brakes Volume 37 0 15 52 37 0 Minimum Volume 15 Maximum Volume Alternate Horn Volume 40 0 15 52 40 0 Minimum Volume 15 Maximum Volume User Sound Effect Volume 46 0 15 52 46 0 Minimum Volume 15 Maximum Volume Crew Talk Volume 52 0 15 52 52 0 Minimum Volume 15 Maximum Volume Water Loading Volume 53 0 15 52 53 0 Minimum Volume 15 Maximum Volume Fuel Loading Volume 55 0 15 52 55 0 Minimum Volume 15 Maximum Volume Maintenance Volume 56 0 15 52 56 0 Minimum Volume 15 Maximum Volume Diesel engine rod knock low RPM 62 0 15 52 62 0 Minimum Volume 15 Maximum Volume Diesel engine rod knock high RPM 65 0 15 52 65 0 Minimum Volume 15 Maximum Volume 4 X refers to the value in column 1 of the table i e the Primary Index number that will be entered into CV49 Setting any Individual Feature Volume in DCC will also apply to Analog and vice versa Future feature not currently available in Atlas Gold Series locomotives Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 27 39 18 June 2012 4 2 6 Selecting Standard Throttle Control or Regulated Throttle Control CV56 4 The differences between Standard Throttle Control STC and Regulated Throttle Control RTC are explained in Section 3 6 Follow the directions below to convert betwee
39. e bell Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 10 39 18 June 2012 3 5 Changing the Locomotive s Direction without Turning off the Sound You can use the power pack s direction switch while the locomotive is in neutral to change the locomotive s direction e Put the locomotive in neutral by bringing the throttle down below V start and wait for the locomotive to stop e Flip the direction switch after you hear the short air release but before you hear the longer air release and the pump sounds turn on During this short time 3 seconds the horn will not blow when you flip the direction switch e Turn up the throttle anytime thereafter to operate the locomotive in the opposite direction If you have waited until the pumps start in neutral and now wish to change direction you can either e Turn the power all the way off change the direction switch and turn the power back on e Flip the direction switch the horn will come on and then turn up the throttle When the locomotive starts to move in the opposite direction the horn will stop automatically and then hoot one more time if the direction is Forward for a total of two hoots Or if the direction is Reverse the horn will hoot two more times for a total of three hoots Note To prevent the first horn hoot from being too long do not delay in turning up the throttle after you have flipped the direction switch 3 6 Standard Throttle Control STC and Re
40. e mover and instead are connected to large resistor grids in the roof By increasing the resistive load on the traction motors the traction motors become harder to turn and act as brakes for the locomotive The electric power generated by turning the traction motors is dissipated as heat by the resistor grid These resistor arrays get quite hot and require cooling When dynamic brakes are turned on in a Quantum equipped diesel locomotive the diesel engine sound drops to notch 1 and the Dynamic Brake cooling fan sounds come on Since Dynamic Brakes are relatively ineffective a low speeds the Dynamic brakes will shut off automatically below 8 smph DCC and QARC Only Doppler Run by The engine sounds get louder as the train approaches then immediately drop to a much lower pitch and lower volume as the train passes by With a little practice you can change the pitch exactly when and where you want Doppler shift is based on the speed of the locomotive so the sounds change more dramatically when the locomotive is running faster After the Doppler shift has occurred and the horn is no longer being blown the bell shuts off automatically and locomotive sounds return to normal Coupler To give you the most authentic coupler sounds QSI has identified three distinct types of coupler activity The first is when the coupler is armed when you will hear the clanking sound of the coupler lift bar and coupler pin raising The next is the sound of the coupler openin
41. eater will be the Doppler shift However there is no Doppler shift below 15 smph 3 3 Special Horn Ending Sound Optional feature not present in all locomotives Prototype engineers would often play their horns by controlling the flow of compressed air In particular engineers often had a signature sound associated with how they ended their horn sequences Some Quantum sound sets have special horn endings that can be activated using the direction switch to produce a unique sound effect similar to playing the horn e Flip the direction switch to blow the horn for at least one second e The normal way to end the horn is to flip the direction switch back To do the special horn ending add an immediate Quick flip and back operation Note If you wait too long to do the Quick Flip and Back operation the bell might turn on instead Note Your Atlas sound equipped locomotive may or may not have the special horn ending sounds included in its feature set 3 4 Operation in Neutral In Neutral the locomotive will continue to make prototypical sounds appropriate to its resting state Enter neutral by turning the throttle down below V Start but not off and wait for locomotive to stop The front headlight or if so equipped the Mars light switches to a steady dim The rear headlight will dim if entering Neutral From Reverse NFR You will hear a short air release when the locomotive stops moving and enters neutral and a longer air release
42. ected by United States copyright laws and international treaty provisions Therefore neither you nor anyone else may copy the software Proprietary Rights and Obligations The structure and organization of the Software Firmware are the valuable properties of QSindustries Inc You will not make or have made or permit to be made any copies of the Hardware Software Firmware code or any portions thereof You are not to modify adapt translate reverse engineer de compile disassemble or create derivative works based on the Hardware or Software Firmware Trademarks shall be used in accordance with accepted trademark practice including identification of trademark owner s name The Quantum Hardware Software and Firmware are covered by U S Patent No 4 914 431 5 184 048 5 267 318 5 394 068 5 448 142 5 633 985 5 832 431 5 896 017 5 940 005 and US and Foreign patents pending No Other Rights QSindustries Inc retains ownership of the Quantum Hardware design and operating Software Firmware code Except as stated above this agreement does not grant you any rights to intellectual property rights to the Quantum Software Firmware or Hardware The use of any trademarks as herein authorized does not give you any rights of ownership in that trademark 2012 All rights reserved Information in this publication supersedes that in all previous published material The contents and the product it describes are subject to change without notice
43. eed switch area to change the direction louder or softer of the volume change Remove the wand when you reach the desired volume level Note Volume can also be adjusted digitally using the programming methods described in the Analog and DCC programming sections of this manual 6 1 3 Turn your Locomotive Off or On using the Magnetic Wand Analog Only Your locomotive can be selected turned on or deselected turned off using the Magnetic Wand When the locomotive is deselected it will remain unmoving and silent with lights off and will not respond to changes in track voltage or Analog horn or bell signals or programming commands 1 To Shut Off a Locomotive a Enter neutral and turn on the bell b Place the Magnetic Wand over the reed switch area The bell will shut off followed by the locomotive shutting down and all lights turning off Note You can turn off a locomotive in a consist even though it has been programmed as a Helper type with disabled bell and horn sound Simply send the bell signal command Even though the bell will not be heard the Magnetic Wand will shut the locomotive down 2 To Turn On a Locomotive a Make sure track power is applied Place the Magnetic Wand over the reed switch area on the locomotive The lights will come of followed by startup sounds The locomotive is now selected and will respond to track voltage and all bell and horn signals b Using the Magnetic Wand makes it easy to turn locomotives off or
44. el engine RPM will increase in fixed increments until the maximum RPM occurs at notch 8 Diesel Turbo On modern diesels turbo appliances are used to improve the engine s horsepower by pumping air into the intake manifold under pressure The power to operate the turbo comes from the diesel engine s exhaust pressure which causes the high pitched whine of the turbo to lag the revving of the engine Quantum systems use a 50 Not all features described here are included in every Atlas Gold Series locomotive Consult the 4 page locomotive information booklet that came with your locomotive for a list of the features and sounds that apply to your particular locomotive 51 QARC or Quantum Analog Remote Control uses special signals under Analog control to operate different Quantum features With QARC you can operate features that are otherwise available only in DCC The Quantum Titan sound decoder and the Quantum Engineer Section 3 12 communicate with each other using QARC messages Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 33 39 18 June 2012 separate sound record for the turbo to allow it to lag behind revving the engine up and to hang for a few seconds when the engine is revved down Dynamic Brakes Electric motors can act as motors or generators depending on whether they are using power or generating power When used as generators the traction motors are disconnected from taking power from the locomotive s prim
45. er off and then back on again Example 1 Setting Throttle Mode Analog Option 10 This option will determine whether your locomotive uses Regulated Throttle Control RTC or Standard Throttle Control STC Enter Programming after powering up your locomotive by turning the bell on then off and then on as described above After the Enter Programming followed by Option One System Volume announcement of the first Program Option flip the direction switch and leave it there You will hear the announcement Option 1 2 3 etc Stop when you hear 10 by moving the direction switch back You will then hear Throttle Mode Use a Slow or Quick operation of the direction switch to enter this option If the throttle mode is at its default value RTC you will hear Mode equals Regulated otherwise you will hear Mode equals Standard Use a Slow or Quick operation of the direction switch to change the throttle mode Repeated Slow or Quick operations will cause the throttle mode to alternate between its two possible values RTC STC RTC STC etc Once you have selected the throttle mode you wish to use turn the throttle off When you power up again your locomotive will be using the throttle mode that you have just selected 2 Setting any volume in Analog will also apply to DCC and vice versa Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 16 39 18 June 2012 Example 2 Setting V Start Ana
46. ermine the deceleration rate Applying the brakes increases the deceleration rate temporarily 34 If the brakes are set in neutral turning up the throttle automatically releases the brakes Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 21 39 18 June 2012 To turn Heavy Load on and off e Press F9 and hear one short hoot when Heavy Load is turned on e Press F9 again and hear two short hoots when Heavy Load is turned off Note You can apply Heavy Load as soon as you start moving or wait until you are up to speed Note Return the throttle to its initial setting where Heavy Load was turned on to avoid acceleration or deceleration when Heavy Load is turned off Note Heavy Load can only be turned on or off in Forward or Reverse If turned on it will remain on in Neutral If you want it off when you start out from Neutral immediately do so when the throttle is turned up Note Heavy Load is automatically turned off when track power is turned off Note Heavy Load represents a train that would take over ten minutes to accelerate to full speed or to bring toa complete stop It is independent of any inertia or momentum values set in CV3 CV4 CV23 or CV24 Note Under RTC and Heavy Load grades voltage changes tight curves or other real loading effects will have little effect on the speed of the train By contrast under STC and Heavy Load grades loading etc will affect the train speed as it moves around the layout 4 1 14 T
47. ey to act as a brake e Press the F7 key Hear a brief brake squeal sound and air being released from the brake lines continually The longer the air is released the greater the braking action e Press the F7 key again to stop the air release The train will continue to slow at the last braking value e If you want to apply more braking press the F7 key again to release more air When you reach the desired amount of braking press F7 again to stop the air release Note If you continue to release air for over 24 seconds total all the pressure will be released and the brakes will be on full you will hear no further air release sounds Turn up the throttle to any value above 0 to release the brakes this action returns the locomotive s deceleration to a value determined by the sum of CV4 and CV24 Note If the locomotive is in Neutral when the F7 key is pressed a long air release sound simulates setting the brakes However no braking effect is activated Note If the throttle is set to any speed step except 0 air brakes are not enabled instead the F7 key will now manually activate squealing brake flange sounds but will not affect the locomotive s deceleration 4 1 12 Mute F8 Key The Quantum System allows you to reduce the System Volume to a lower level or increase it back to its original setting using the F8 function key This capability is useful when you need to reduce the sound to engage ina conversation or to answer the phone If y
48. f the bell turning on turn the bell off with a second Quick flip and back operation e Within three seconds turn the bell back on again with a third Quick flip and back operation Note If you delay too long after power has been first applied the opportunity to enter programming will time out and you will need to start again by shutting off and reapplying track power Once you perform the three bell operations after applying power the bell will shut off automatically you will hear Enter Programming and the front and rear headlights will flash alternately off and on 3 13 2 Scrolling through the Program Options After entering programming you will hear an announcement of the first Program Option Option 1 System Volume To access other Program Options simply flip the direction switch to the opposite position and leave it there Listen as each option number is announced in order Flip the switch back and leave it there when you wish to stop at a particular option After you stop at an option you will hear the option number and name announced When you are scrolling through and stopping at Program Options you are not making any changes To make changes you must actually enter the Program Option Note If you accidentally go to a higher option number other than the one you wanted simply turn the power off re enter programming and start again Once you reach the last Program Option the Quantum Titan sound decoder will continue to ann
49. g along with the hiss of the air lines parting The third is when the locomotive couples up to its load of cars and you hear the crash as the cars bunch together from the impact DCC and QARC only Flanges When a train enters a curve the flanges on the wheels ride up on the inside of the rail and squeal Recreate this squealing effect by pressing and releasing the Brake Squeal Flanges button quickly and repeatedly as necessary DCC and QARC only Horn The Quantum System uses authentic locomotive sounds whenever possible All Quantum horns are engineered by our sound experts to give you the most authentic effects If you blow the horn briefly you will produce a realistic short horn sound or hoot Low Idle Low Idle is used on prototype locomotives to maintain a warm and ready locomotive with a minimum of fuel consumption The special Low Idle sound has a lower base throb and is less harsh than the normal idle 6 Special Operation and Troubleshooting For a full description see the Troubleshooting section in the latest Quantum DCC Reference Manual You can find this document on the QSI Solutions website http www gsisolutions com by clicking on DOWNLOADS AND MANUALS going to the bottom of the webpage and double clicking on the first bullet item under the General heading On the QSI Solutions webpage the document is called Full DCC Reference Manual for All QSI Decoders With some DCC systems using the horn button to a
50. gulated Throttle Control RTC Atlas sound equipped locomotives have two types of throttle control available Standard and Regulated Both Standard Throttle Control STC and Regulated Throttle Control RTC will apply more power to the motor as track voltage increases beginning at the V Start setting RTC includes a motor speed control feature that prevents the locomotive from reacting quickly to changes in voltage or to minor impediments such as misaligned track joints tight curves rough switches etc A locomotive operating under STC may come to an unrealistic halt from a raised track joint or a drop in voltage while the same locomotive under RTC will continue at the same speed RTC operates your locomotive as though it has the mass and inertia of a prototype locomotive your locomotive will resist changes in speed once it is moving and will resist starting up quickly if at rest You will be able to operate your locomotive at very slow prototypical speeds without having to adjust your throttle continually to maintain speed While small obstacles will not affect the locomotives speed under RTC a continual force will slow your train down just as is the case with the prototype For instance if your diesel locomotive encounters a grade under RTC it will eventually slow down Providing more throttle will slowly accelerate it back to speed The same locomotive under STC would quickly slow down or stop when it encounters a grade The type of thro
51. guration Squeal 56 128 n Reset Load on off toggle 56 253 Version Build Information Fan on off toggle 62 Auto CV Verbal Feedback enabled Verbal Engine Status 64 CV Inquiry Verbal Readout Grade Crossing Signal 115 Feature to Port Mapping Audio Mute 116 Individual Sound Balance Control System Volume Control 117 QSI Individual Sound Selection Plus additional features 118 Individual Sound Pitch Shift 120 Ready to Move Scenario Settings in parentheses indicate factory default QARC Technology allows commands to be sent to locomotives under Analog control to operate different Quantum features With QARC technology you can operate features that are otherwise available only in DCC plus features that are not yet available in DCC The Quantum Engineer controllers are inexpensive accessories that employ the QARC system They can be added to your existing power pack to operate additional features on your Quantum equipped locomotive Quantum Analog Remote Control QARC Technology 58 Not all Quantum equipped locomotives contain QARC Technology Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 38 39 18 June 2012 QSindustries Inc Software License Agreement 1 Grant of License QSindustries Inc grants you the owner and the right to use the software that is included with your Quantum system only with the locomotive that you purchased 2 Copyright The software is owned by QSindustries Inc and is prot
52. gy you can operate features that are otherwise available only with Digital Command Control DCC In particular QARC will allow you to Turn on or off lights Shut down and start up locomotives Make up consists easily Simplify Analog programming Set System Volume or Mute while train is operating Trigger Coupler Crash sounds Operate prototype like Air Brakes Turn on Dynamic Brakes Activate verbal speedometer readout Operate many other features The QARC System makes Analog operation more fun and more prototypical Every button on a QARC controller does exactly what it is labeled to do The major difference between QARC and DCC is that with QARC you are unable to operate multiple trains running at different speeds independently on the same powered section of track at the same time The QARC controller called the Quantum Engineer can be added to your existing Analog power pack Wiring is simple two wires go to the variable DC output from the power pack and two wires go to the track All features on the power pack remain the same including throttle and reverse switch control For further information on the Quantum Engineer Controller see the Quantum Engineer Operating Manual Ver 2 0 on the QSI web site at http www qgsindustries com 3 13 Analog Programming An Atlas Sound Equipped Diesel Locomotive can be Programmed on a DC layout in either of two ways e Use a Standard Power Pack Almost all advanced analog operations
53. hanges in Direct Mode while the locomotive is on the program track Turn off Blast Mode programming by changing the setting of Option Switch 07 to off a Press the PROG key b Press the SWITCH key c Use the keyboard to enter 07 which is the number of the Option Switch that you need to turn off d Press the t key to turn Option Switch 07 off e Press the EXIT key when you are finished setting Option Switch 7 If your locomotive has a QSI sound decoder and you set CV62 0 in Step 2 put the locomotive back on the main line run it briefly at its new 4 digit address and configure the Zephyr or Zephyr Xtra for Operations Mode programming Now change CV62 back to its default value of CV62 1 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 30 39 18 June 2012 4 2 8 3 Special Procedures for Short or Long Address Programming for Lenz and Other DCC Systems that Do Not Normally Permit Address Programming on Main Line CV56 129 If you cannot program your Short or Long address in Service Mode and your Lenz or other DCC command station prevents you from setting either of these addresses in Ops Mode on the main line using CV1 or CV17 and CV18 use one of the following two alternative procedures to program your locomotive s address e Alternate Procedure for Programming Short Addresses in Ops Mode Set CV49 to 129 Set CV50 to 1 Set CV56 to your short address range 1 127 for most DCC system
54. hers The default value of CV29 is 6 The following table provides some of the more common values for CV29 and the features that these values support Table 8 Available Features for Various Values of CV29 If You Want this Set of Features Write this Decimal Pan Atomar Operates Locomotive Norma Value E A ESE p Uses 28 or 128 Direction into g eta ane On DC Speed Steps of Locomotive CV67 CV94 p p CV29 2 No No Yes Forward 2 2 No Yes Yes Forward 6 2 Yes No Yes Forward 18 2 Yes Yes Yes Forward 22 4 No No Yes Forward 34 4 No Yes Yes Forward 38 4 Yes No Yes Forward 50 4 Yes Yes Yes Forward 54 2 No No Yes Reversed 3 2 No Yes Yes Reversed 7 2 Yes No Yes Reversed 19 2 Yes Yes Yes Reversed 23 4 No No Yes Reversed 35 4 No Yes Yes Reversed 39 4 Yes No Yes Reversed 51 4 Yes Yes Yes Reversed 55 48 You will not hear CV62 0 This option is not affected by CV62 Disable Enable Verbal Announcements Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 32 39 18 June 2012 Two common values for CV29 that allow both DCC and DC operation are 6 2 digit address and 38 4 digit address For more information download the NMRA DCC Reference Manual for QS Quantum FX Q2 and Q1 Equipped Locomotives Version 5 0 2 or later You can find this document or a more recent version of it on the QSI Solutions website http www qsisolutions com
55. hree Stages of Diesel Locomotive Shut Down 1 Disconnect 2 Standby 3 Total Shut Down double press F9 Key Locomotive Shut Down has three distinct stages that you can control Each stage is entered by double pressing the F9 key Stage One Disconnect Double press the F9 key in neutral to enter Disconnect You will hear a long air let off To leave Disconnect either double press the F6 Start Up key as described in Start Up Section 4 1 9 or double press the F9 key again to reach the next stage of Shut Down Standby If you double press the F9 key in neutral the motor drive will be disconnected Once you hear the long air let off the DCC throttle can be moved up and down without the locomotive moving As the throttle is moved up or down you will hear the diesel engine in the locomotive rev up and down in proportion to the throttle setting Note You can also turn on the Dynamic Brakes see description of Dynamic Brakes in Section 4 1 7 to create Sound of Power as the throttle is moved up and down Engineers on prototype diesels use the Dynamic Brakes to load the diesel motor generator to test its output and efficiency while the locomotive remains stationary Stage Two Standby While in Disconnect quickly press the F9 key twice to enter Standby You will hear a long air let off followed by a special Low Idle sound The Directional Lighting system and optional ditch lights or Mars Light will shut down The engine will remai
56. ies to both steam and older diesel locomotives since diesel locomotives that supply steam to passenger cars need to have their water supply refreshed periodically For all locomotives you will hear sounds of water running into the locomotive s water tank Note The Water Loading Scenario is available only with Quantum Titan sound decoders 4 1 22 Function Key Operation in Neutral Some function keys used in Forward and Reverse will have different effects when used in Neutral Pressing F6 results in Doppler shift for a moving locomotive but activates Start Up in Neutral e The F7 key produces Squealing Brake Sounds or applies brakes for a moving locomotive but produces a Long Air Let off in Neutral in diesels Pressing F9 turns on off the Heavy Load feature in a moving locomotive but activates Shut Down in Neutral Pressing F15 triggers the grade crossing scenario but only in Forward or Reverse Pressing F26 triggers the fuel loading scenario but only in Neutral Pressing F27 triggers the maintenance scenario but only in Neutral Pressing F28 triggers the water loading scenario but only in Neutral 4 1 23 Automatic Features with Take Control Operation The Quantum System allows the operator to take control of certain automatic features by using their associated function key or keys Once you Take Control the features will no longer have automatic operation and you will control their operation and their state with functio
57. iesel Locomotive User Manual 31 39 18 June 2012 4 2 9 Disable Enable Verbal Announcements CV62 In Ops mode the Quantum System will automatically announce the value of the CV that you entered e To disable set CV62 to 0 e To enable set CV62 to 1 Default is enabled 4 2 10 CV Inquiry with Verbal Feedback in Ops Mode CV64 To inquire about the current value of any CV through Verbal Feedback in Ops Mode e Set CV64 to the number of the CV you wish to query e Hear the verbal message CV xX equals Y where X is the CV number and Y is the value If the CV has a Primary Index such as QSI CVnn mm where nn is the CV number and mm is the Primary Index e First set CV49 to mm e Then set CV64 to nn For example if you want to inquire about the Bell Volume which is CV52 8 see Section Error Reference source not found set CV49 to 8 and then set CV64 to 52 You will hear CV five two point eight equals Y where Y is the current volume setting Note If you enter either 17 or 18 into CV64 you will hear the full Long Address ID number spoken out 4 2 11 Selecting a Value for CV29 CV29 is the most important of all the Configuration Variables in DCC Each bit in CV29 controls some basic operational settings for DCC decoders such as Extended 4 digit Addressing user defined Speed Table enable Power Source Conversion operate on DC and DCC or only on DCC Locomotive Direction and ot
58. ing to a stop The availability of CV6 to adjust the mid range speed of a locomotive Using CV6 to set directly the mid range speed is an alternative to using CV25 to select a speed curve Gradual brightening and dimming of locomotive lights when they are turned on and off Lower minimum locomotive speeds Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 8 39 18 June 2012 3 Analog Features Most analog features can be accessed from any variable DC power pack that has a standard reversing switch However there are some features that can be accessed more easily from the Quantum Engineer or are only accessible from the Quantum Engineer See Section 3 12 for a discussion of the Quantum Engineer 3 1 Starting the Locomotive Most variable DC power packs with a standard reversing switch are suitable for analog operation of Atlas sound equipped locomotives Generally modern electronic type power packs will provide better performance When operated with a standard DC power pack your Atlas sound equipped diesel locomotives behaves quite differently from non sound equipped locomotives that you may have operated Unlike standard DC locomotives that start at very low track voltages Atlas sound equipped locomotives require a minimum amount of voltage to operate the electronics Also their response to the throttle is much slower and more like that of a prototype locomotive Turn the throttle up slowly until you hear the Quantum S
59. iption Option s Entering Option POP s16 1 System Volume Volume equals X Sets System volume 17 levels where level 16 is maximum volume and level 0 is off 16 Max 2 Load Load equals X Selects the starting and stopping momentum for both Regulated Throttle Control RTC 0 No Load and Standard Throttle Control STC Level 0 no load Level 1 15 increasing load with acceleration to full speed from 15 seconds to 210 seconds in RTC and from 3 seconds to 45 seconds in STC 3 Helper Helper equals Selects Normal Lead Mid End or Pusher Helper in consists Normal Normal Normal Locomotive has all sounds and lights enabled Lead Lead Locomotive has all sounds enabled and its rear headlight disabled Mid Mid Helper has horn bell and all lights disabled End End Helper has horn bell and all lights disabled Pusher Pusher has rear headlight on all the time as train warning light Horn bell and all lights except Number Boards are disabled 4 Direction Direction equals X Selects if the features associated with the locomotive s direction are normal or Normal reversed 5 7 Reserved Reserved 8 V Start 8 5v V Start equals X Sets track voltage where locomotive will leave neutral See the V Start Example below 9 V Max 12v V Max equals X Sets track voltage where full power is applied to motor See the V Max Example below 10 Throttle Mode
60. itan system has made this operation even more convenient When the locomotive is in FWD or REV press the F15 key once to trigger the grade crossing horn signal If you press the Horn key during the Grade Crossing scenario you will terminate this feature and take control of the Horn Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 23 39 18 June 2012 You can use CV55 154 SI to change the number of horn blasts and length of each horn blast in the grade crossing signal Note The Grade Crossing feature is currently assigned to F15 by default only with Quantum Titan sound decoders 4 1 19 Fuel Loading Scenario F26 Key in Neutral Press the F26 key when the locomotive is in NFF or NFR neutral from forward or neutral from reverse to trigger a fuel loading scenario For diesel locomotives you will hear sounds of diesel fuel being pumped into the locomotive s tank Note The Fuel Loading Scenario is available only with Quantum Titan sound decoders 4 1 20 Maintenance Scenario F27 Key in Neutral Press the F27 key when the locomotive is in NFF or NFR to trigger a maintenance scenario For diesel locomotives you will hear sounds of the diesel engine being revved up and down automatically Note The Maintenance Scenario is available only with Quantum Titan sound decoders 4 1 21 Water Loading Scenario F28 Key in Neutral Press the F28 key when the locomotive is in NFF or NFR to trigger a water loading scenario This scenario appl
61. las sound equipped locomotive may not have all lights described here depending on the particular locomotive you have 7 Itis not necessary to wait for the engine start up sounds to finish before entering forward If you turn up the throttle the startup sounds terminate and the diesel locomotive will immediately go into normal forward operation 3 V Start is set by default at 8 5 volts It is important to note where V Start is located on your throttle to know where you will enter and leave neutral see Operation in Neutral Section 3 4 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 9 39 18 June 2012 http www qsindustries com 3 2 Doppler Effect This sound effect changes the horn pitch and diesel engine sounds as your locomotive passes by you e While the locomotive is moving toward you flip the direction switch to turn on the horn e Wait at least one second while the horn is blowing e Flip the direction switch back and forth quickly so the horn does not shut off You will hear the horn and other diesel locomotive engine sounds shift in pitch as the locomotive passes by you e Either flip the direction switch back to shut off the horn or continue with long or short horn operations e When you are finished blowing the horn the locomotive sounds will automatically return to normal after a few seconds If the bell was on it will shut off just before the sounds return to normal Note The faster the locomotive is moving the gr
62. log Option 8 This option will determine the voltage and throttle position at which the locomotive will leave neutral and start moving To change V Start perform the following operations e Enter Programming after powering up your locomotive by turning the bell on then off and then on as described above e After the Enter Programming followed by Option One System Volume announcement of the first Program Option flip the direction switch and leave it there You hear the announcement Option 1 2 3 etc Stop when you hear the number 8 by moving the direction switch back You will hear V Start e Use a Slow or Quick operation of the direction switch to enter this option You will hear V Start equals X where X is the track voltage value currently set to leave neutral e Use a Slow or Quick operation of the direction switch to activate this option You will hear the message Set throttle to V Start When you hear this message move the throttle knob on your DC power pack to the new voltage you wish to use for V Start After three seconds the V Start track voltage will be announced If you move the throttle again another new value for the V Start track voltage will be announced a few seconds later e Once the throttle is set to the voltage you wish to use for V start use a Slow or Quick operation of the direction switch to begin the voltage setting procedure The bell will ring continually in
63. lume equals X Customizes Flange Squealing Brake Volume 16 levels Max is 15 31 Dynamic Brakes Volume Volume equals X Customizes Dynamic Brake Cooling Fan Volume 16 levels Max is 15 32 Coupler Volume Volume equals X Customizes All Coupler Sound Volumes 16 levels Max is 15 33 Reserved Reserved X is the current value of the Program Option Defaults are shown in parenthesis next to the option name 18 POP is short for Program Option 17 The verbal programming responses such as Enter Programming etc have a minimum volume setting to provide programming information even when the system volume is turned all the way off 18 You can set volume with the manual volume control with programming or with both The manual volume control will determine the range of volume available under programming that is if you turn the manual volume control down to say 50 you will not be able to increase the volume above the 50 value using programming 19 Some lights that are not controlled by the Quantum System may remain on Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 15 39 18 June 2012 3 13 1 Entering Analog Programming Use this sequence of actions to enter programming using the direction switch e Apply power and turn up the throttle to hear the sound system come on e Within five seconds of powering up turn on the bell with a Quick flip and back operation e Within three seconds o
64. n RTC and STC when using DCC e Set CV49 to 4 e Set CV56 to 0 for Standard Throttle Control or to 1 for Regulated Throttle Control Note The default is Regulated Throttle Control Note CV2 CV3 CV4 CV5 and speed tables apply to both Standard and Regulated Throttle Control 4 2 7 Reset All CV s to their Factory Default Values CV56 128 255 e Set CV49 to 128 e Set CV50 to 255 e Set CV56 to 113 In Ops Mode you will hear Reset when reset is completed Note This reset does not affect any Analog settings except for volumes Note Atlas strongly recommends that you reset your locomotive using the magnetic wand Section 6 1 1 rather than by this method 4 2 8 Programming a New DCC Address for Your Locomotive The decoders in DCC locomotives normally come from the factory set to use the short address 3 However in order to control independently multiple locomotives on the same track at the same time it is necessary that each of these locomotives have a different address Most model railroaders pick as an address the road number printed on the side of the locomotive s cab Quite frequently the road number on the side of the cab is a 3 or 4 digit number which is treated as a Long or 4 digit Address in DCC Most DCC systems allow you to change the short range is 1 127 for most DCC systems or the long address in either of two places e Ona special section of track that is not connected in any way to your layout and is
65. n disconnected while the Air Pumps automatic Cooling Fan Operation Number Board Lights if illuminated separately from the headlight and Cab Lights will continue to operate In Standby the locomotive will not respond to the throttle or to most of the function keys The three exceptions are the F6 Start Up Function Key Section 4 1 9 the F8 Mute Key Section 4 1 12 and the F10 Status Key Section 4 1 15 To leave Standby either double press the F6 Start Up key as described in the Start Up section or double press the F9 key again to reach the final stage of the Shut Down process which is called Total Shut Down Note Standby is ideal for leaving your locomotive running on a siding Besides hearing the low idle diesel engine sounds the locomotive will not respond if you accidentally change the throttle setting or press a function key Stage Three Total Shut Down If you double press the F9 key while you are in Standby you will enter Total Shut Down As the locomotive goes into Total Shut Down you will hear a long air let off To leave Total Shut Down double press the F6 key If you double press the F9 key while in Standby you will hear a long air let of after which the locomotive will advance to Total Shut Down The air pumps will turn off followed by the number boards turning off the sounds of the cooling ae Double pressing ensures that Shut Down stages are not entered or exited accidentally Double pressing is defined as two
66. n key commands Automatic and Take Control operations are explained in the table below Table 5 Diesel Locomotive Take Control Operation Automatic Operation Take Control Operation Feature Forward Reverse Neutral ER Operation Vents amp Non operating Non operating On and off at F4 Toggles Vents Fans operation Cooling Fans random times between on or off Cab Lights Off after 10 Off after 10 On after 10 F12 Toggles Cab Lights on or off if equipped seconds seconds seconds For example take Control of Automatic Fans by using the F4 key to stop automatic operation and control whether the Cooling Fans are on or off Regardless of the state of the automatic fans on or off if you press the F4 key the cooling fans will be set to on if the F4 key is 1 and to off if the F4 key is 0 and automatic operation will be disabled Thereafter the fans will respond only to the state of the F4 function key Automatic operation will be restored if the power is shut down and reapplied or if the F6 Start Up key is double pressed in neutral See the description of DCC Start Up in Section 4 1 9 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 18 June 2012 4 2 DCC Programming Although most DCC systems currently available are capable of programming non sound locomotives in either Service Mode on the program track or in Operations Mode on the main line many current DCC systems do not provide
67. n switch on your power pack to blow a short long horn code to trigger the maintenance scenario For maximum realism press once only the Disconnect Standby key on your Quantum Engineer Controller to put the locomotive into the Standby state Then use the throttle on your DC power pack to rev the diesel engine up and down without the locomotive moving When you wish to end the Maintenance Scenario press the Start Up key on your Quantum Engineer Controller to return to normal operation Note The Maintenance Scenario is available only with Quantum Titan sound decoders e Water Loading Scenario Horn Code is long short short short When the locomotive is in the NFF neutral from forward or the NFR neutral from reverse state use either the horn button on the Quantum Engineer or the direction switch on your power pack to blow a ong short short short horn code to trigger a water loading scenario For all locomotives you will hear sounds of water being run into the locomotive s water tank Older diesel locomotives that supply steam to passenger cars would need to have their water supply refreshed periodically Note The Water Loading Scenario is available only with Quantum Titan sound decoders 3 11 2 Timing of Horn Blasts It may take some practice to get the proper lengths of the horn blasts so that they will trigger the above scenarios The following information should help e Minimum and Maximum Lengths in msec of Short Horn
68. ng air release at various times Bell Diesels and Electric locomotives as well as larger steam locomotives usually have pneumatically operated mechanical bells Small steam locomotives often have hand pulled bells During turn on in neutral hear the pneumatic clapper gain greater throw with each stroke until it finally strikes the bell During shut down in neutral you will hear the bell fade out along with the short air release sound associated with turning this appliance off Brake Squeal You can hear the brakes squeal on prototype locomotives when the locomotive is moving slowly and this noise can become particularly loud when the wheels are just about to stop turning Listen at slow speeds for automatic brake squeal sounds and the final distinctive squealing sounds as the diesel locomotive slows to a stop Cooling Fans The enormous diesel engines and generators which are enclosed in the diesel locomotive body need ventilation in order to stay cool All diesel locomotives have powerful cooling fans on the roof to draw outside air through louvers on the sides of the locomotive The outside air is blown across large radiators You will also hear the sounds of louvers opening before the fans start When cooling fans shut down you will hear the louvers close Diesel Engine Rev Quantum allows the diesel engines to be operated with all eight notches corresponding to the throttle notches used on the prototype As the throttle is turned up the dies
69. ngs from level 1 to 15 Under acceleration the engine sounds will be more labored until the locomotive has achieved its final speed where it will then produce standard sounds appropriate to its throttle setting Under deceleration the diesel engine sounds are less labored until the locomotive achieves its final speed where it will again produce standard diesel engine sounds appropriate to its throttle setting 3 9 Helpers Prototype Helpers are locomotives that are used to provide extra power and or braking for a heavily loaded train These locomotives can be part of the head end consist or act as mid train helpers or as pushers at the end of the train Helper locomotives behave differently from the train s lead locomotive The horns and bells on helper locomotives are usually not operated and their lighting options are different or not used at all When you make up your train using more than one locomotive the Quantum System allows you to program easily how each locomotive will behave by selecting between a Lead locomotive Mid Helper End Helper or Pusher Each type of helper locomotive has different lighting and sound characteristics as described in the table on page 15 in Section 3 13 Analog Programming 3 10 Normal and Reversed Direction The Quantum Titan sound decoder also allows you to reverse the directional sense of your locomotive This is normally not an issue with DC two rail trains since all locomotives will go in the same direction
70. ns for Adjusting the volumes of various sounds Setting locomotive DCC addresses complete programming information Getting a verbal report of the value of a Configuration Variable CV when the loco is on the mainline Changing between Regulated Throttle Control RTC a variation on cruise control that uses back EMF to control the speed and Standard Throttle Control STC e Advanced Level Information You need advanced level documentation for the QSI Quantum Titan sound decoder if you wish to do more complex operations such as Speed matching the locomotives in a consist Programming the lights of the locomotives in a consist so that only the appropriate lights of each locomotive are illuminated Controlling lighting behavior dimming flashing directionality Adjusting various lighting parameters timeouts ramp up rates etc Advanced Level information about QSI Quantum Titan sound decoders is NOT included in this document If you want to know the details of how a particular feature works or you want to modify typically by reprogramming CVs the way a feature operates you will need to download the document NMRA DCC Reference Manual for QS Quantum FX Q2 and Q1 a Equipped Locomotives Version 5 0 2 or later This Reference Manual contains definitions of the CVs used in Quantum Titan sound decoders and includes examples of how to program various combinations of CVs to obtain particular locomotive
71. nufacturer s ID Number as assigned by the NMRA Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 28 39 18 June 2012 Table 7 Methods for Programming a 4 Digit Address on the Main Line for Various DCC Systems Support 4 Digit Recommended DCC System Model Address 4 digit Address Manufacturer Programming Programming in Ops Mode Procedure Bachman EZ Command No Not recommended for use with Atlas Gold Series locomotives Bachman Dynamis No Use procedure in Section 4 2 8 1 or use Program Track CVP Products EasyDCC No Use procedure in Section 4 2 8 4 or use Program Track Digitrax Zephyr or Zephyr xtra No Use procedure in Section 4 2 8 2 without a DT400 type throttle or use Program Track Digitrax Empire Builder Super Chief or Yes Use procedure in Section 4 2 8 1 Zephyr Zephyr xtra with a DT400 type throttle Lenz Compact or Atlas Commander No Not recommended for use with Atlas Gold Series locomotives Lenz All other Lenz DCC systems No Use procedure in Section 4 2 8 3 With Ver 3 0 or later software or use Program Track MRC Prodigy Express Yes Use procedure in Section 4 2 8 1 Prodigy Advance and Advance or Prodigy Wireless NCE PowerCab or PowerPro Yes Use procedure in Section 4 2 8 1 4 2 8 1 Special Procedure for Long 4 Digit Address Programming of Gold Series Locomotives on Main Line works with most DCC systems In order to program a Long 4 digit address in Ops Mode when your Atl
72. ocomotive on the main track and run it on DCC using address 3 or whatever other address you have programmed into the locomotive If you can t determine the address reset the locomotive with the magnetic wand on a DC POWERED track using the procedure described in Section 6 1 1 Then test run the locomotive on DCC using the main track and DCC address 3 Since your locomotive has a QSI sound decoder keep the locomotive on the main line and use Operations Mode programming to set CV62 0 This operation maximizes the probability that CV29 will be set to its typical 4 digit address value of CV29 38 in Step 8 below This step is not always needed but it is impossible to tell if the step is necessary without going through the entire programming sequence Turn Option Switch 7 on so that you can use Digitrax s Blast Mode programming feature a Press the PROG key on your Zephyr or Zephyr xtra DCC system b Press the SWITCH key c Use the keyboard to enter 07 which is the number of the Option Switch that you need to turn on d Press the c key to turn Option Switch 07 on e Press the EXIT key when you are finished setting Option Switch 7 If you took the locomotive to be programmed off the main track put it back on the track If DCC track power is off turn it back on using the POWER key on the Zephyr or Zephyr xtra Make sure that the locomotive to be programmed still runs on DCC using address 3 or whatever other address you have prog
73. ocomotives make sure that both locomotives have similar speed throttle characteristics by adjusting V Start and V Max to prevent them from fighting each other For additional information on analog programming download the Quantum Q1a Analog Reference Manual Ver 4 0 from http Awww qsindustries com 21 Quantum systems have a built in voltmeter that measures the track voltage and announces its value verbally Depending on the power pack this voltage may be slightly different than values measured by an external meter However since the Quantum voltmeter uses its own values for throttle levels it is the correct value for the system 22 See Section 3 13 4 Moving on to Other Program Options or Leaving Programming 23 V Max should not be set too low when using RTC For most MRC power packs the best choice for V Max is about 1 5 volts below the highest throttle setting as determined by the Quantum internal voltmeter 24 Do not double head Quantum engines with standard engines and then operate the horn or bell while engines are moving The standard engine will reverse direction and fight with the Quantum engine Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 17 39 18 June 2012 4 DCC Features 4 1 Function Keys The following table lists features that have been pre assigned to DCC function keys Operation of these function keys can be different in the neutral state locomotive stopped and the moving states locomotive
74. ogramming a long address make sure that your DCC system has activated this long address i e it has set CV29 to a value that supports 4 digit addresses see Section 4 2 11 In particular if you have a Digitrax DCC system that has a DT400 type walk around throttle be certain to press the Y key IMMEDIATELY after you see Ad4on y displayed on the throttle screen 5 Change your DCC system from its configuration for Operations Mode programming to its configuration for running a locomotive on the main line if your DCC system doesn t perform this reconfiguration automatically 6 Verify that the locomotive can operate on the main line using its new 4 digit address 7 Ifthe locomotive responds properly to the new address re enable verbal announcements by using Operations Mode programming again to set CV62 1 In this case you will hear verbal confirmation of the CV62 value of 1 that you just entered since you have just re enabled verbal announcements Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 29 39 18 June 2012 4 2 8 2 Special Procedure for Long 4 Digit Address Programming on Main Line with Digitrax 1 NO 11 12 Zephyr or Zephyr xtra DCC Systems If you have a DT400 DT402 throttle plugged into your Zephyr or Zephyr xtra DCC system you do not need to use the procedure described in this section Instead use the procedure described in the previous section Section 4 2 8 1 Put your l
75. omatic Cooling Fans and Dynamic Brakes Doppler Shift locomotive Inertia Brake or Flange Squeal Helper Type Normal Programming Modes Supported Neutral Sounds Normal loco Lead Loco Address Mode Register Mode Service Long Air Release Mid Helper End Helper Mode Direct Mode Ops Mode Long Form amp Short Air Release Pusher Ops Mode Short Form Air Pumps Direction Normal Sound of Power Normal Reversed NMRA CV s supported Neutral State Idle Power Pack Programming 1 Primary Address Directional Lighting V Max 12v 2 V Start Bright Headlight V Start 8 5v 5 V High Reverse Light optional 6 V Mid Mars Light optional Shut Down amp Start Up 8 QSI MFG s ID Number 113 Number Board Lights optional with Magnetic Wand 3 4 7 11 17 25 29 66 95 Cab Lights optional QSI QARC Operation Fuel Loading Scenario with QS Quantum QSI CV s supported Water Loading Scenario Engineer Controller 49 Primary Index Maintenance Scenario Air Brakes 50 Secondary Index Flanges 51 Sound Control Dynamic Brakes 51 0 System Volume Manual Volume Control Engine ID s 51 1 Mute Volume with Magnetic Wand Consist ID s 51 2 Doppler Enable disable Reset to Factory Default Coupler Sounds 51 20 Ready to Move Scenario with Magnetic Wand Diesel Extended Shut Enable Disable Down 52 Individual Sound Volume Control Extended Start Up 53 Function Output Mapping Explicit Lighting Control 56 QSI Feature Configuration Controllable Flange 56 QSI Confi
76. omotive coupling Use the F3 key again as the locomotive moves out to trigger the same sound as the slack is taken up in the cars Use the F3 key in neutral to produce uncoupling sounds as you disconnect cars over uncoupling magnets Press the F3 key once to produce the sound of the lift bar and coupling pin being raised This also arms the uncoupling sound effect Press the F3 key again while moving or in neutral to trigger the sounds of the coupler knuckle opening and the air lines parting 4 1 5 Diesel Fans and Louvers F4 Key Pressing the F4 key and releasing it will cause the sounds of the Diesel Fans and Louvers to come on and stay on until you press the F4 key again ee Explicit lighting control features for the front headlight rear headlight and optional ditch lights or Mars Light can be assigned to DCC function outputs See the NMRA DCC Reference Manual for QS Quantum FX Q2 and Q1 Equipped Locomotives Ver 5 0 2 or later 28 Quantum uses constant voltage lighting that is independent of track voltage Since the prototype horn uses compressed air you may hear the air pump sounds turn on after the horn is operated Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 19 39 18 June 2012 4 1 6 Sound of Power Your diesel locomotive will produce labored diesel engine sounds under acceleration and lighter diesel engine sounds under deceleration but only if CV3 or CV23 and CV4 or CV24 are set to non zero positive values
77. on DCC ccccccceseeeseeeeceneeeeeeeeaeeceaeeesaeeseaeeseaaeeseaeeseaeessaeeseaeeeseaeeseaeeeseaeeseieeeseeeseas 37 6 4 Reasons Why Your Locomotive is Silent or Will Not Start Analog and DCC cccceceeeceeeeeeseeeeteteeteeetees 37 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 6 39 18 June 2012 1 Introduction Congratulations on purchasing an Atlas HO scale or 2 rail O scale Gold Series sound equipped locomotive that is equipped with the QSI Quantum Titan system the most feature packed and technologically advanced sound decoder available today The documentation for Gold Series locomotives with Quantum Titan sound decoders is divided into three parts e _Basic Level Information The information at this level is designed to get you running your new Gold Series Titan locomotive on either conventional DC or on DCC as quickly as possible This basic level information is contained in the Quick Start Guide to Atlas Gold Series Locomotives which is at the very beginning of this manual right after the cover page e Intermediate Level Information This Atlas Gold Series Diesel Locomotive User Manual explains how to use features in the Quantum Titan sound decoder such as controlling the various available sound effects such as Aijr Brakes Dynamic Brakes Shut Down and Start Up Heavy Load Grade crossing signaling Various maintenance scenarios Also included in this document are instructio
78. oo quickly if at rest and will resist changes in speed once moving See Section 3 6 Standard Throttle Control STC and Regulated Throttle Control RTC It takes a little practice to learn to move the throttle slowly and wait until the locomotive responds If you prefer that your locomotive respond almost immediately to throttle movements on your DC power pack it may be reprogrammed to use Standard Throttle Control STC Example 1 on page 16 in this User s Manual explains how to program your locomotive to use STC on a DC layout As you slow the locomotive down by gradually reducing the throttle to a little below V start the diesel engine s rev and labored sounds volume decreases while squealing brake sounds occur as the diesel locomotive comes to a slow stop If you need to turn your throttle up quite high to start your diesel locomotive V Start can be adjusted for operation with your particular DC power pack see Example 2 on page 17 in this User s Manual For a list of recommended power packs consult the Quantum Q1a Analog Reference Manual Ver 4 0 which may be downloaded from 5 Some electronic power packs do not have a reverse switch Instead they have a reverse button which does not cause a rapid change in track polarity to the track and is not suitable for Quantum operation See the list of suitable power packs in the Quantum Q1a Analog Reference Manual Version 4 at http www gsindustries com 6 Your At
79. otive drops below 7 smph or the throttle is turned up Dynamic Brakes cannot be turned on in Forward or Reverse unless the locomotive is traveling over 8 smph Note In contrast to Air Brakes F7 Dynamic Brakes do not increase the deceleration rate specified by CV4 and CV24 4 1 8 Doppler Effect Operation single press F6 Key With DCC you can trigger the Doppler Effect by quickly interrupting the horn signal in the same way described under Analog Operation Alternatively you may use the Function Key F6 dedicated to the Doppler Effect Start the horn and or bell by pressing and releasing their function keys Press F6 once to hear the Doppler shift A few seconds after the horn button is turned off with the F2 key the diesel engine sounds will return to normal 4 1 9 Start Up double press F6 Key If your Atlas sound equipped diesel locomotive is in any stage of Shut Down you can return your locomotive to normal operation by double pressing the F6 Key Start Up will be different for each stage of Shut Down but a locomotive in any stage of Shut Down will start up with a long air release and then will enter normal operation e Start Up from Disconnect If you double press the F6 key in Disconnect the diesel locomotive will produce a long air let off dynamic brakes will shut off if on and the locomotive will enter normal operation e Start Up from Standby If you double press the F6 key in Standby the diesel locomotive will produ
80. ou have many trains operating at once you can reduce the volume on all those that are running in the background of the layout and increase the volume of the closest locomotive The Mute feature changes the sound gradually over a second or two which allows the sound to increase or decrease realistically as the locomotive approaches or recedes from the observer Press the F8 key in Neutral or Forward Reverse to gradually decrease or increase the locomotive s volume Note Mute state is not maintained if power is turned off and back on the locomotive will return to full volume setting Note Mute volume can be programmed in CV51 1 4 1 13 Heavy Load single press F9 key If Heavy Load is applied while the train is moving it maintains the train at a steady speed while allowing you to have control over the sound effects of a working locomotive Under Heavy Load changing the throttle will have little effect on the locomotive s speed Instead you can use the throttle to control your locomotive s laboring Sound of Power sound effects When you approach a grade under Heavy Load increase the throttle and hear the locomotive work hard with heavy laboring sounds When the locomotive goes down a grade reduce the throttle to diminish the locomotive s laboring sounds You can control how hard the locomotive works by changing how much the throttle is increased or decreased from its initial position where Heavy Load was turned on 33 CV4 and CV24 det
81. ounce the last option number 3 13 3 Entering a Program Option and Making Changes After the verbal announcement of a Program Option you can enter that option by performing a Slow or Quick flip and back operation of the direction switch Upon entering a Program Option you will hear the current setting for that option For unused Program Options you will hear Reserved For any volume option you will hear Volume equals x where X is its current volume level setting After a moment you will hear the sound playing at its current volume Note Entering a Program Option does not change the settings for that option it only provides information about its current value After entering the Program Option additional Slow or Quick flip and back operations will program new settings as described in the table above For all level adjustments a Quick operation will decrease one level while a Slow operation will increase one level Note Since System Volume is the first Program Option you can use Quick or Slow operations immediately after entering programming to change the system volume 3 13 4 Moving on to Other Program Options or Leaving Programming Flip the direction switch at any time to the opposite position and leave it there Quantum will first return to and announce the current program option and will then automatically advance to onto higher numbered options Exit Programming anytime you want to do so by turning the pow
82. packs produce excessive voltage at max throttle and will activate the Quantum high voltage circuit breaker When this happens your engine will stop and emit a series of hoots until the power is reduced to a lower voltage see High Voltage Circuit Breaker Section 6 2 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 12 39 18 June 2012 3 11 1 Triggering the Scenarios in DC Operation The scenarios are available in both conventional DC operation and DCC operation With DC track power these scenarios are triggered by sequences of long and short blasts of the horn The locomotive must be in a neutral state either NFF neutral from forward or NFR neutral from reverse before you can trigger any of these scenarios e Fuel Loading Scenario Horn Code is short short long When the locomotive is in the NFF neutral from forward or the NFR neutral from reverse state use either the horn button on the Quantum Engineer or the direction switch on your power pack to blow a short short long horn code to trigger a fuel loading scenario For diesel locomotives you will hear sounds of diesel fuel being pumped into the locomotive s tank Note The Fuel Loading Scenario is available only with Quantum Titan sound decoders e Maintenance Scenario Horn Code is short long When the locomotive is in the NFF neutral from forward or the NFR neutral from reverse state use either the horn button on the Quantum Engineer or the directio
83. perate the secondary horn in the normal way DCC function F13 to decrease System Volume by 2 dB DCC function F14 to increase System Volume by 2 dB DCC function F15 to play the Grade Crossing horn sequence long long short long but only when the locomotive is moving DCC function F26 to start the Fuel Loading Scenario dialog and sounds appropriate to fueling with diesel oil but only when the locomotive is stopped DCC function F27 to start the Maintenance Scenario but only when the locomotive is stopped DCC function F28 to start the Water Loading Scenario but only when the locomotive is stopped For example this scenario might be used to generate dialog and sounds appropriate to adding water to the steam generator in a diesel passenger locomotive In order to use the above new features you need a DCC system that supports DCC functions FO and F1 F28 Most currently sold DCC systems do support FO and F1 F28 If your DCC system does not support the total range of these functions check with the manufacturer of your system to see if an upgrade is available Other New Features Other newly available features of Quantum Titan sound decoders include The availability of CV51 20 to set up or turn off automatic horn warning signals that will be generated by the sound decoder including Two short horn blasts when starting in FWD Three short horn blasts when starting in REV One short horn blast when com
84. r available today The Quantum Titan sound decoder includes all the features of the original QSI Quantum system used in previously released Atlas Gold Series locomotives plus many new features This section will discuss briefly these new features Quantum Titan Architecture The Quantum Titan sound decoder has a new architecture that gives it considerably more horsepower than earlier sound decoders from QSI and other manufacturers Some highlights of this new architecture are Higher speed processors A 64 Mbit memory This much memory allows the Titan system to store multiple diesel horns or other sounds that can be chosen by the user Initially one of two diesel horns can be selected by the user Up to 128 mono sound channels are available Ten selectable lighting outputs that are each programmable for any of eleven different lighting effects Note An individual Atlas locomotive will utilize only a subset of the above capabilities not all of them Additional DCC Functions Available with Quantum Titan The original QSI Quantum DCC and sound system used DCC functions FO and F1 F12 to control various sounds lights and other features The new Quantum Titan sound decoders use DCC functions F13 F28 in addition to FO and F1 F12 The new Titan system uses the functions F11 to F28 to trigger the following features DCC function F11 to toggle between the primary and the secondary horns After pressing F11 once F2 will o
85. rammed into it Keep pressing the PROG key until you see PAGE on the Zephyr s or Zephyr xtra s display Keep pressing the LOCO key until you see AD4 on the Zephyr s or Zephyr xtra s display Use the keyboard to enter the 4 digit address that you wish to program e g 1234 or any other address between 128 and 9983 When you have finished entering the 4 digit address write this new address into your locomotive by pressing the CV WR key Do not be surprised if the locomotive leaps forward when the programming takes place This movement doesn t always happen but it can To exit Blast Mode programming on the main line press the EXIT key on your Zephyr or Zephyr xtra To run the locomotive whose address you entered in Step 7 press the LOCO key re enter the address you entered in Step 7 by using the Zephyr or Zephyr xtra keyboard and press the LOCO key again Verify that the locomotive runs using its new address If the locomotive did not run in Step 11 when you used its new address a Turn off DCC track power and move the locomotive that you are trying to program from the main line to the program track b Using Direct Mode programming or whatever other type of programming your decoder requires read the values of CV29 and AD4 For 4 digit addresses the value of CV29 should be 38 and AD4 should be the address that you entered in Step 7 c If either or both of these values are not correct change it them You may make any necessary c
86. rottle a little more to remain below V Start 12 Standard prototype railroad signaling is two hoots before starting in forward and three hoots before starting in reverse Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 11 39 18 June 2012 3 7 Engine Load You can set your diesel locomotive to have any of 16 different loads also called inertia or momentum levels see Analog Programming Section 3 13 As you increase track voltage the motor in your locomotive is provided an increasing portion of that power which depending on the load setting will gradually accelerate the locomotive realistically until it reaches full speed Level O is the default which is no load Under STC the level 0 load setting will allow your locomotive to accelerate or stop as quickly as its internal flywheels will allow Under RTC level 0 will add no additional load to the built in inertia already provided by RTC For any load setting from 1 15 your diesel locomotive will take longer to change speed under either STC or RTC With RTC at level 1 it will take approximately 15 seconds more to achieve full speed at max throttle at level 15 it will take over 3 Ye minutes to achieve full speed In addition at higher load settings your locomotive will decelerate more slowly as you decrease your throttle 3 8 Sound of Power The diesel locomotive will produce Sound of Power labored diesel engine sound effects if you have selected any of the load setti
87. s Hear the address spoken back f necessary set CV29 to 6 which is the factory default to enable your new short 2 digit address e Alternate Procedure for Programming Long Addresses in Ops Mode Determine the values of CV17 and CV18 that correspond to your locomotive s 3 or 4 digit ID number either by using one of the CV17 CV18 calculators available on the Internet such as http ruppweb dyndns org xray comp decoder htm or else by following the instructions for calculating the values of CV17 and CV18 in the NMRA DCC Reference Manual for QS Quantum FX Q2 and Q1 Equipped Locomotives Version 5 0 2 or later Set CV49 to 129 Set CV50 to 17 Set CV56 to the value for CV17 that you determined in Step 1 Set CV50 to 18 Set CV56 to the value for CV18 that you determined in Step 1 Set GV64 to 17 Hear the new full Long 3 or 4 digits Address spoken out Set CV29 to 38 to allow operation with your new Long Address 4 2 8 4 Special Procedures for Long Address Programming on the Main Line for CVP Products EasyDCC System The EasyDCC system from CVP Products allows you to program on the main line the two CVs that hold a 4 digit address CV17 and CV18 but it does not allow you to program the 4 digit address directly 1 Determine the values of CV17 and CV18 that correspond to your locomotive s 3 or 4 digit ID number either by using one of the CV17 CV18 calculators available on the internet su
88. s required of a prototype locomotive engineer when he starts and stops his locomotive e Two short horn blasts when the locomotive first starts to move in FWD e Three short horn blasts when the locomotive first starts to move in REV e One short horn blast when the locomotive comes to a stop To enable or disable these horn warning signals perform the following steps e Set CV49 to 20 e Set CV51 to 0 to disable all Horn Warning Signals or set CV51 to 17 to enable all three of the Horn Warning Signals listed above If you want to enable a different horn warning scenario from those specified above please refer to the definition of CV51 20 in the NMRA DCC Reference Manual for QS Quantum FX Q2 and Q1 Equipped Locomotives Ver 5 0 2 or later If you want to modify the timing duration and or number of horn blasts in a Horn Warning Signal scenario please refer to the definition of CV120 PI SI in this same reference manual Note This Automatic Horn Warning Signals feature is available only with Quantum Titan sound decoders 39 PI stands for Primary Index SI stands for Secondary Index Refer to Sections 5 1 to 5 3 in the QSI DCC Reference Manual pages 89 to 94 in Version 5 0 2 for an explanation of the Indexed CVs used in QSI sound decoders Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 26 39 18 June 2012 4 2 5 Changing Individual Sound Volumes CV52 X To change the volume of individual sounds listed in the t
89. silent after power up and turning the power off for 15 seconds does not return it to normal operation try the following suggestions to bring your locomotive back to normal sound operation Make sure the locomotive has not been Muted with the F8 Key Check to see if your manual volume using Magnetic Wand or digital volume has been turned all the way down You may have shut your locomotive down in DCC using the F9 key which remains in effect in Analog or it has been shut down using the Magnetic Wand in Analog Go back to DCC operation and start your locomotive with the F6 key Once started you can return to DC or DCC operation Or use the Magnetic Wand in Analog which selects and starts the locomotive if it has been shut down If the above methods do not start your locomotive reset your locomotive to factory default values using the magnetic wand as described in Section 6 1 1 54 It may take a couple of tries to get it started Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 37 39 18 June 2012 Quantum Titan Features Available in Analog DC and DCC Operation Sounds amp Features a H Common to Analog amp DCC Analog Features DCC Features Horn or hoot System Volume FO or FL light control Bell with shut down and turn on Programming F1 F28 Function Keys effects Individual Sound Volume 14 28 126 speed steps 28 Diesel Engine Control Coupler Sounds Diesel Turbo optional Regulated Throttle Control Air Brakes Aut
90. sometimes activate if the load inertia or momentum feature is used Most power packs have substantial series resistance which lowers the track voltage when the engine is drawing power However with a load setting the engine does not require much power when it first starts moving If the throttle is turned all the way up before the engine gains speed the track voltage will be unusually high and can trigger the high voltage circuit breaker Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 36 39 18 June 2012 6 3 Program Track Operation DCC This locomotive conforms to NMRA standards for program track operation However the Quantum sound system like almost all other sound decoders requires more current to operate than standard decoders and may not respond to the limited program track power available from many DCC systems If you cannot program your Atlas Gold Series locomotive on the program track you have two choices 6 4 Add a program track booster such as the PowerPax from DCC Specialties or the PTB100 from Soundtraxx between the program track output of your DCC system and the program track All CV s in your locomotive can be programmed on the main line in Ops Mode If you don t know the loco s current address you will have to reset it using the magnetic wand Section 6 1 1 and then program it as loco 3 Reasons Why Your Locomotive is Silent or Will Not Start Analog and DCC In case your locomotive remains
91. tive User Manual 2 39 18 June 2012 If you do a Slow flip and back operation you will get a short horn hoot instead of the bell If you try to do a very short horn blast using a Quick operation you will activate the bell instead If you have trouble doing the Quick flip and back operation try holding the power pack in place with your other hand to keep the pack from slipping DCC Operation Quick Start Read through this section and be up and running in fewer than five minutes with your new locomotive on a layout that uses any DCC system that is compatible with the NMRA DCC specifications e Running the Locomotive on DCC Select locomotive number 3 on your DCC system Set your DCC system to use either 128 preferable or 28 acceptable speed steps Start your locomotive immediately by pressing the F6 DCC function key to hear the diesel engine start up sounds The Directional Lighting front headlight rear headlight and optional Ditch Lights or Mars Light 2 will be off Use the FI or FO key to turn on Directional Lighting The cab lights if equipped and number board lights if equipped will be on The cab lights will shut off automatically after ten seconds When you reduce the DCC throttle to zero the locomotive will automatically enter the neutral state after the locomotive stops moving You will hear a short air release when the locomotive stops moving and a longer air release about one second later followed by air pumps and other b
92. trol independently several locomotives on the same track at the same time it is necessary that each locomotive have a different DCC address A convenient choice for the DCC address is the road number printed on the side of the locomotive s cab Frequently the number on the side of the cab is a 3 or 4 digit number which is treated in DCC as a Long or 4 digit Address Most DCC systems allow you to change the DCC address of a locomotive in either of two places On a special section of track that is not connected in any way to your layout and is called the Program Track In DCC terminology programming locomotives on the program track is called Service Mode Programming Anywhere on the regular track of your layout In DCC terminology programming a locomotive on the track of your layout is called either Programming on the Main POM or Operations Mode Ops Mode Programming If your DCC system allows you to program 4 digit addresses on the main line many DCC systems do Atlas recommends that you take advantage of this capability by programming the address of your Gold Series locomotive on the main line using Operations Mode Ops Mode programming The table in Section 4 2 8 shows for most of the DCC systems commonly sold in North America both those that do and those that do not directly support 4 digit address programming on the main line For those DCC systems that do NOT support Ops Mode address programming this table recommends that yo
93. ttle control also affects how your locomotive decelerates Under STC your locomotive will respond quickly to a reduction in track voltage Under RTC your locomotive will decelerate slowly as you bring the throttle down If you bring the throttle down below V Start the locomotive will slowly come to a stop You can however force a locomotive to slow down rapidly under RTC by bringing the throttle down quickly this action reduces the available power to the motor speed control circuit and forces the speed to decrease faster than RTC would normally allow Once the locomotive slows down and regains normal RTC operation it will continue to decelerate slowly according to its built in inertia For instance if your locomotive were running at top speed and you quickly reduce the track voltage to just below V Start where the locomotive would normally be stopped the locomotive will at first slow down rapidly since you have reduced the available power to the motor After this initial rapid slow down the locomotive will decelerate at a rate determined by the RTC inertia and will then finally coast to a stop STC and RTC are selected on a DC layout by using Analog Programming see Section 3 12 The factory default setting is RTC 1 On some power packs that have high internal resistance the track voltage may rise slightly as the locomotive slows down and requires less power to operate With these power packs as the engine slows you may need to reduce the th
94. u use one or several of the alternate main line address programming procedures that are described in Sections 4 2 8 2 through 4 2 8 4 For all other DCC systems use the Ops Mode programming procedure that is described in Section 4 2 8 1 Resetting your Locomotive to Factory Default Values Using the Magnetic Wand _ resets all Analog and DCC parameters Resetting the firmware in the Titan sound decoder to its factory built configuration can resolve many problems that sometimes occur with firmware controlled electronics In fact we have found that at least 20 to 25 percent of the problems with Gold Series locomotives that we receive for repair at Atlas can be resolved simply by resetting the sound decoder Hence the very first step you take to resolve a problem should be to reset the Quantum Titan sound decoder in your locomotive Every Atlas sound equipped locomotive has a magnetic reed switch located directly under the top of the plastic shell This switch can be activated by the Magnetic Wand the T shaped object packed with your locomotive without having to disassemble the locomotive Atlas recommends using the magnetic wand to reset whether your locomotive is normally operated on DC or on DCC Please note that it is essential to use conventional DC track power for this magnetic wand reset procedure to work properly The reset procedure is described in Section 6 1 1 Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 4 39 18 June 2012
95. und equipped locomotive on a section of track that is powered by conventional DC 3 Locate the reed switch area on the top of the locomotive The arrow in the photo of your Atlas Gold Series locomotive that appears on page 3 of the 4 page locomotive information booklet packed with the locomotive points to the location on the top of the locomotive under which the reed switch is located 4 Place the Magnetic Wand over the reed switch area on the top of the locomotive at the location determined in Step 3 and with the metal shiny silver part of the wand parallel to the ties of the track and on or just above the top of the locomotive The magnet the shiny silver cylinder should be horizontal with one circular end pointing towards one side side NOT end of the locomotive and the other end pointing towards the other side Keeping the wand in the small plastic bag in which it was shipped prevents possible marring or scratching of the locomotive 5 Slowly and gradually apply conventional DC power to your track until the track voltage increases from 0 to approximately 8 to 10 volts f the magnet is in the correct location along the length of the locomotive and with the silver part parallel to the ties the locomotive will not move and there will be no sound until you hear reset spoken in Step 6 below 6 While continuing to hold the magnetic wand on or just above the top of the locomotive keep increasing the track voltage slowly until you hear
96. ween 0 no sound and 127 maximum volume The default System Volume is 127 Note In Operations Mode when you change the System Volume you will immediately hear the new System Volume 4 2 2 Changing the Mute Volume Electronically CV51 1 To change the Mute Volume in Service or Ops Mode do the following e Set CV49 to 1 e Enter the desired Mute Volume in CV51 The Mute Volume can be set to any value between 0 no sound and 63 maximum volume The default Mute Volume is 0 Note In Ops Mode when the locomotive is muted and you change the Mute Volume you will immediately hear the new Mute Volume Note The Mute Volume level will be the smaller of either the Mute Volume setting or one half the current System Volume In other words the Mute Volume will never be more than one half the System Volume 4 2 3 Enable Disable Horn Triggered Doppler Shift CV51 2 e Set CV49 to 2 e Set CV51 to 0 to disable Horn Triggered Doppler set CV51 to 1 to enable Horn Triggered Doppler 37 System Volume changes in DCC also apply to Analog and vice versa 38 You will hear the value 0 you entered for CV49 spoken out Ops Mode Only Atlas Gold Series Quantum Titan Diesel Locomotive User Manual 25 39 18 June 2012 4 2 4 Enable Disable Automatic Horn Warning Signals CV51 20 You can use CV51 20 to enable or disable the following automatic horn warning signals that can be generated by the Quantum Titan sound decoder This scenario imitates the action
97. whether they are facing forwards or backwards However certain features like directional lighting or diesel Low Idle do depend on the directional sense For instance if you program your locomotive to be an End Helper its rear headlight operates when the locomotive is moving in Reverse and the front headlight is disabled This is ideal for providing a rear headlight for the train However if this diesel locomotive is facing backwards at the end of a consist its rear headlight will be facing forwards and will be lit when the consist is moving Forward furthermore there will be no rear headlight for the consist The Direction program feature will ensure that this End Helper s backward facing front headlight will come on only when the consist is backing up and the forward facing rear headlight will not light at all When making up a train with different Helper types it is recommended that you also change the directional sense of a Helper that is intended to be operated backwards within the consist See Option 4 Direction in Analog Programming Section 3 13 3 11 Fuel Loading Water Loading and Maintenance Scenarios HO scale and 2 rail O scale Atlas Gold Series locomotives that are equipped with the Quantum Titan sound decoder offer three different scenarios that cover the following situations e Loading fuel into the locomotive e Performing maintenance on the locomotive e Loading water into the locomotive 13 Some unloaded power
98. ystem come on with air let off sounds The number board lights and front headlights will turn on The front headlight will come on dim If your locomotive has operating ditch lights the front headlight will be dim and the ditch lights will be off If your locomotive has a Mars Light the Mars light will be dim and the front headlight will be off See the tables in Section 4 1 1 that summarize front headlight rear headlight operation You will hear the diesel engine in your locomotive start up followed by the air pumps If the prototype locomotive has two diesel engines you will hear both engines start one after the other Continue to turn up the throttle voltage until the locomotive starts to move in Forward this voltage is called V Start The diesel engine s sounds will rev up with labored sounds proportional to the locomotive s acceleration and loading see Sound of Power Section 3 8 and the locomotive will slowly start to move The Headlight will switch to bright and the optional Mars light will begin to pulse After 10 seconds in Forward the Cab Lights if installed in your locomotive will automatically shut off Locomotive Inertia Effects Your new locomotive is pre programmed at the factory to use Regulated Throttle Control RTC in Analog conventional DC powered operation RTC makes your locomotive operate as though it has the mass and inertia of a prototype locomotive As a result your locomotive will resist starting up t

Download Pdf Manuals

image

Related Search

Related Contents

Samsung E1270 1.77" 82.9g Black  EW-NA42 - Panasonic  User`s Manual Princeton HP-11 DIGITAL PIANO  MSI AC1900  "取扱説明書"  Graco 3A1696C User's Manual  Manual Bioself      ActiveFloor  

Copyright © All rights reserved.
Failed to retrieve file