Contents
1. sccssscsssssssscsssssssccsscssccsssccssscssscsscsssasssssssscsssssssssssssscsssees 1 2 TECHNICAL DATA SUMMARY sss0sssoseenssesosesnssenssennssenssensennssennsesnsssnssensnensnesnsssnnsessnessssenee 1 2 1 TRIMMER POSITION TOP VIEW s lt s0s dscevcsevecetscssicevectsseesieovscetssseavsosccevsvutdseseadssetveodsacdssedvasseseteseve 1 3 OPERATING INSTRUCTIONS visssssssscssssssnsssscssoscsnscsstsssnsseassenssenssoessoesscencossccsssassssessensseassoseses 2 31s GEOBALZ OPERATIONS ne raten RURHNENIS TTR 2 3 2 FAN OPERATIONS amp csssessssvsxsoscasssvesasesesetecevssesseveasossetevausdsetesetssoracsvudeceverddbesceedesdtcsebatacseulevsssdudstes 3 3 3 POWER SUPPLY MONITORING AND CONTROL OPERATIONS sssscseesseeeesseeeeesseeeesseeeesseeeeeseeeees 3 3 4 CAN BUS INTERFACE OPERATION cccssssccesssccesseeecesseccesseecsseeceesseceesseecesseeesesseeeesseeeesseeeesseeeens 4 3 5 ERROR MESSAGE LIST neresini aai a a i i i aai e 6 ZL Run timeerror Messages enna kirah ia AREETA S 7 4 PINASSIGNM EN eeaeee renee arera Sr eo e rE e EErEE ES TE E EAEE E 8 4 1 DCOUTPUT CONNECTOR 75 PIN cscccssssccessscceesscccesscecesseecessecsesseccesaescesaeeceesseceesseseseseeesenaees 8 4 2 FAN CONNECTOR EXT 15 PIN eeeesneesnesssnesnnessnnsnnnesnnensnnssnnsnnnnsnnennnnssnnssnnessnnssnnssnnessnnsssnsssnennn 8 4 3 MONITOR CONNECTOR 36 PIN ov eccesccccssssccessecceesscecesceecessecscseecsesseceesseecseseecsesseeessaeecseseeeeenaees 8 4 4 CANBU
2. 3300 m 20 kbit s low speed 10 kbit s Skbit s To adjust the net speed for a given net length select the bit rate according to this table and set on the crates 1 Select display channel SPEED with MODE SELECT switch 2 Switch up or down the ADDR switch to select the required rate 3 5 Error message list Both W IE NE R power supplies and fan trays are equipped with micro processor based monitoring and control units Thus any fan or power module failure will be detected and on the alphanumeric display an error message is shown This is a useful information for trouble shooting January 13 6 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH 3 5 1 Error messages during self test after switching on Unit failures CHKS CONF Configuration check sum error CHKS UCAL Check sum error of calibration voltage CHKS ICAL Check sum error of calibration current PROM CONN internal CPU error CHKS ADDR Check sum error of netware address CHKS STAT Check sum error of previous mains on off status CHKS FAN Fan tray check sum error 3 5 1 Run time error messages FANOFF Fan failure TEMP OFF Temperature of power supply too high AC FAIL Failure of ac power line January 13 7 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH 4 Pin assignment 4 1 DC output connector 75 pin U0 6V 32A Sense U1 3 3 V 32A Sense U2 3 3 V 8A Sense U3 6V 8A Sense G
3. 3V 8A U3 6V 8A 2 1 Trimmer position top view vo v ul u January 13 1 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH 3 Operating Instructions 3 1 Global operations POWER ON OFF switch up on green POWER LED lights switch down off SYSRESET not used MODE SELECT switch up next mode switch down previous mode On the alphanumeric display in the centre of the front panel the values of fan speed temperatures voltages and currents as well as the adjusted voltage and current limits will be shown To choose between the available modes push the MODE SELECT switch The following table gives a look about all available modes and shows examples for the displayed values reserved reserved 3V 12V channel 6V 12V channel 6V 12V channel 3V 12V channel FANS Fan Speed PS TEMP power supply temp AIR TEMP fan air inlet temp POWER total output power CAENET opt CAENET interface addr CANBUS opt CAN interface addr SPEED CAN serial link speed GENERAL CALL CAN general call address January 13 2 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH 3 2 Fan operations FAN SPEED switch up step wise increase of fan speed switch down step wise decrease of fan speed AUTO OFF switch up auto off enabled a fan failure will set off the crate switch down auto off disabled a fan failure will not set off the crate only local and r
4. S CONNECTORS gt ITEM 3 4 cccsscccsssscccessceeesseecessecseseeccesseecesseecssseeesesseccesseeceeseeeeeseees 8 January 13 ii UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH Description of UEP10M005 The W IE NE R UEP10M0O05 is a linear regulated Power Supply for a special application Output voltages and load currents accord to the specification of the customer Mechanical construction fits into a 19 cabinet The required height is 5 units plus unit for air flow All switches displays and fuses are located in the front of the unit The mains plug the dc output plug the external fan plug the monitor plug and the CANbus plugs are mounted on the rear Two fans are mounted inside the power supply to cool down the power transistors It is very important to provide a good airflow and to avoid any suppression of free air circulation The circuit is a classical one of a linear regulated power supply The bipolar power transistor are driven by a regulator circuit which contains the necessary elements such as references operational amplifiers small signal transistors and the required trimmers These components are accommodated on two similar boards each regulating one positive and one negative voltage An additional board provides control functions such as trip off overload and overtemperature The required dc voltages are supplied by a mains transformer via rectifiers and electrolytic capacitors An add
5. W Ie Ne R UEP10M005 Power Supply User s Manual UEP10M005 A0 General Remarks The only purpose of this manual is a description of the product It must not be interpreted a declaration of conformity for this product including the product and software W Ie Ne R revises this product and manual without notice Differences of the description in manual and product are possible W Ie Ne R excludes completely any liability for loss of profits loss of business loss of use or data interrupt of business or for indirect special incidental or consequential damages of any kind even if W Ie Ne R has been advises of the possibility of such damages arising from any defect or error in this manual or product Any use of the product which may influence health of human beings requires the express written permission of W Ie Ne R Products mentioned in this manual are mentioned for identification purposes only Product names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies No part of this product including the product and the software may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means with the express written permission of W Ie Ne R January 13 i UEP10M005 A0 dieses Dokuments Wann _ Kommentar vH1 Versionen 1 Table of contents 1 DESCRIPTION OF UEP10M005
6. crease 4 To accept the new value switch down POWER To change the other limits repeat step 1 4 5 Disconnect mains to end programming January 13 3 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH The following table represents possible values for the current resolution and the standard settings SmV A 6V 3 3V 10mV A 25mv A mn a 3 3V 6V 50mV A Further it is possible to define the unit behavior after AC on or AC failure It is possible to select either a general crate is off after connecting to AC or an automatic power on to allow the unit to switch automatically on after AC fail 1 Switch on fan tray and select channel POWER with MODE SELECT switch 2 Switch up both POWER and MODE SELECT switches together for about 5 sec Then the controlling mode menu including auto power on or no auto power on be shown on the display Change the value by pushing the MODE SELECT switch down or up 4 To accept the new value switch down POWER 3 4 CAN bus interface operation If equipped with the optional CAN bus interface the front panel is equipped with additional elements for network operation SWITCHES ADDR CAN bus crate address LOCAL not used LED INDICATORS LOCAL green large LED lights if CAN Net OK January 13 4 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH The 9 pin Sub D connector for CAN bus interfacing is prepare
7. d according to CiA DS 102 1 iT ine i Comment reserved by CiA 2 CAN_L CAN_L bus line dominant low GND Ground reserved by CiA 6 CAN_H bus line dominant high reserved by CiA failure signal To change the CAN bus address the ADDR switch has to be pressed The address can be selected within the range 1 127 The chosen net address is displayed on the fan tray display If the display has been showing another parameter voltage fan speed 9 before changing the net address it will return to the previous display To shut the crate for remote control the position CANBUS DISABLED has to be chosen Within the W IE NE R CAN bus protocol a broadcast call to all connected crates is possible see CAN BUS Interface report The address for this general call is factory prepared 127 however it can be changed by the following procedure 1 Select display channel GENERAL CALL with MODE SELECT switch 2 Switch up or down the ADDR switch to change the value If the crate has to be disabled for general call the position GENERAL CALL OFF has to be selected January 13 5 UEP10M005 A0 User s Manual UEP10M005 W Ie Ne R Plein amp Baus GmbH According to the CAN bus specification the data transfer speed is depending on the net length as given within the following table 10 m 1 6 Mbit s 40 m 1 0 Mbit s 130 m 500 kbit s high speed 250 Kin 125 kbit s 100 kbit s 1300 m 50 kbit s
8. emote warning is given The maximum value of fan speed is up to 3120 rpm If the speed is lower than 3000 rpm the red SLOW SPEED LED lights Change of fan speed is possible independently from the displayed mode If another range of the display was set before pushing the FAN SPEED switch the display shows the speed for 5 sec and returns back to the previous range The display shows the nominal speed of the blowers and twinkles if it differs from the given real speed The yellow FAN FAILURE LED lights in the case of any fan failure 3 3 Power supply monitoring and control operations All present voltage and current values of the several voltage output lines as well as the temperature inside the power supply can be shown on the alphanumeric display of the fan tray To select between the display modes push the MODE SELECT switch as given in 2 2 In case of using the linear regulated power supplies UEP series it is possible to define the current resolution for each voltage These values which are stored within the fan tray unit can be programmed by the following switch algorithm 1 Switch on fan tray and select channel e g 12V with MODE SELECT switch 2 Switch up both POWER and MODE SELECT switches together for about 5 sec Then the controlling mode menu including selected channel and the current resolution will be shown on the display 3 Change the value by pushing the MODE SELECT switch down value will decrease or up value will in
9. itional auxiliary power supply drives the mains relay and soft start circuit A micro controller circuit is built in to achieve comfortable watching over the complete unit The display and switches in front the internal and external fans the status of power supply the air temperature and the CANbus are serviced and controlled by this processor circuit The top and bottom covers can be removed for access to internal components Only specially trained personal with the necessary equipment must maintain the power supply For access to the voltage trimmers the necessary holes in the top cover can be used Severe malfunction may result adjusting any other trimmer January 13 1 UEP10M005 A0 User s Manual W Ie Ne R Plein amp Baus GmbH UEP10M005 Technical data summary Input Fuses Noise and ripple Regulation Recovery time Output impedance Derating Temperature error Thermal protection Current characteristics Voltage range Crow bar DC outputs 115VAC 10 15 8A time lag 5x20mm fullload lt 0 6mV eff 3mVpp ImV at 80 rated power load 10 to 100 lt 0 05 line 10 lt 0 02 load change 10 to 100 lt 0 15ms static lt 0 2mOhm 48 63Hz no derating at SOdegrees Celsius lt 200ppm switches on heat sink and transformer current limit adjusted to 115 rated current short circuit current lt 3A adjustment range gt 5 attention tripoff at 2 5 7 3V U0 6V 32A Ul 3 3V 32A U2 3
10. round Common Sense PE chassis ground 4 2 Fan connector ext 15 pin Ufan lt 24V 1 9 Ufan Gnd 2 10 Pulse Fan 1 3 Pulse Fan 2 4 Pulse Fan 3 5 4 3 Monitor connector 36 pin Uo Monitor 3 U1 Monitor 4 U2 Monitor 2 U3 Monitor 5 Gnd analog 9 Rearming 35 Rearming 34 39 40 4 1 42 66 29 47 48 49 50 67 30 55 31 57 32 43 44 45 5 1 52 53 56 58 60 63 26 27 65 Statusbit 23 Statusbit 11 Disable 28 Inhibit 26 Power fail 12 Gnd digital 8 4 4 CANbus Connectors gt Item 3 4 January 13 8 UEP10M005 A0 Seite i 1 Kommentar vH1 Dr Lider von Horn Versionen dieses Dokuments Wann Was Wer 5 Juli 99 Manual erstellt L von Horn
Download Pdf Manuals
Related Search
W Ie wienerschnitzel w ieee standard c95.1-2345 wiesbaden wielerflits wienerberger wielkanoc 2025 wie ist meine ip wiener linien wien energie wien wetter wiesbadener volksbank wieistmeineip.de speedtest
Related Contents
Memorex miniMove Mix3 Holmes 13ESM1 User's Manual Instruction booklet AuditWizard v8 - Layton Technology, Inc. Samsung SM-T116 Инструкция по использованию User Manual - Chart Industries Mise en page 1 Wenger/SwissGear Roadster Configuring%Intel%Windows%8%Hardware% OM, Automower, Solar Hybrid, 2012 Copyright © All rights reserved.