Home

User Manual - H and R Healthcare

image

Contents

1. Incorrect battery replacement may result in risk of explosion Replace only with same or equivalent battery type recommended by the manufacturer 6 If the equipment needs maintenance contact H amp R Healthcare as soon as possible For equipment that is no longer functional make sure to follow national and or state requirements for disposal of the unit 7 Ensure that any disposal of the unit accessories waste products residues etc complies with national and local law 8 The power plug serves to disconnect the device and should not be positioned in a way that makes it difficult to disconnect 9 No modification of this equipment is allowed 10 To avoid the risk of electric shock this equipment must be connected to a supply mains with protective earth 11 To shut down the unit press the power button CAUTION ENSURE THAT THERE ARE NO PROTRUDING OBJ ECTS SHARP POINTS OR BED SPRINGS UNDER THE MATTRESS AS THESE COULD PUNCTURE THE AIR CELLS 4 0 System Package Power Unit Package e Power Unit x 1 e Power Cord x 1 e Operational Manual x 1 Mattress Package e Mattress replacement unit with coverlet x 1 SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 5 0 Features i i 7 static 395 0000 cal 250 aan ff K 200 Fe A mode S 150 _ 7 ee a k r 5 100 weighit Ibs a Se 5 alternating a Se mn J a Do o S Fi hia o o i
2. Ses e j o d SIGNA RELIEF Healthcare 800 8501 5537 Control Panel Features Power Mute The green power LED will light when the main power rocker switch on the right side panel is turned on Weight Ibs Simply press weight button to adj ust patient weight from 100 Ibs to 325 Ibs according to patient weight The scale is only an approximation Please adjust the weight setting if the mattress is too soft or firm to suit each patient s needs Caregivers should always perform a hand check by placing their hands underneath patient s pelvis area to check if there is sufficient air LIS power mute A support to ensure the patient is not bottoming out Alert LED 1 This alert notifies medical staff the mattress has insufficient pressure Audible alarm will sound for 15 seconds at each cycle and the indicator will stay on until the problem has been solved Pressure monitoring LED Power unit features an integrated pressure sensor which monitors the mattress internal pressure to ensure maximum pressure relief LED indicates that the system is monitoring the mattress internal pressure while the compressor is inflating Alternating Static Press Mode to change between alternating and static mode Alternating mode will have a cycle time of 10 minutes SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 6 Right Side Panel Features a if F p f A F n AL i EE
3. 5 Patient s wounds are not responding to pressure relief reddening of skin 13 0 Returns for Service Service and repair must be performed by an H amp R Healthcare authorized technician or representative Please contact H amp R Healthcare at 800 801 5533 14 0 Warranty H amp R Healthcare warrants this product against manufacturer defects for one year from the date of placement Please inspect this product upon purchase and notify H amp R Healthcare if there is any damage or missing parts Warranty coverage will not be extended to any product on which the production lot number has been removed or defaced on which repair has been attempted by any person or agency not authorized by H amp R Healthcare or if in the sole Please contact H amp R Healthcare for assistance Contact your physician and or nursing service immediately opinion of H amp R Healthcare the system shows evidence of tampering abnormal or unreasonable abuse negligence accident or operation without regard for the restrictions specified in the instructions which accompany the system This warranty does not cover routine maintenance such as cleaning adjustment lubrications and updating of equipment or parts If inthe sole opinion of H amp R Healthcare the damage is not covered under this warranty the purchaser will be responsible for labor and parts costs The warranty stated above is the only warranty made and
4. I i a A i P i Pa Th 2 5 a f Z Rocker Switch 1 Power unit s main power switch Couplers 2 Quick release female couplers are used to secure mattress air hoses to power unit Power Receptacle 3 Insert power cord firmly into receptacle Rear Panel Features Convenient Handle 1 The handle provides additional gripping surface for user to carry the power unit Hanging Hooks 2 Hanging hooks are designed to hang the power unit on almost any foot board Fuse 3 Fuse Holder Air Filter and Cap 4 H amp R Healthcare recommends that the filter be kept clean to ensure optimal performance of the power unit 6 0 Mattress and Power Unit Installations 1 Remove existing mattress from bed frame 2 Place H amp R Healthcare mattress replacement on the bed frame with the logo at foot end Secure the mattress at each side using anchor straps Ensure that the anchor straps do not interfere with any moving parts of the bed frame before proceeding to the next step 3 Secure the power unit onto the foot board using hanging hooks 4 Ensure that the mattress CPR latch is firmly inserted and the CPR tag is in place SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS re 7 Press the power mute button to Caregivers should always Firmly connect the air hose 3 IMPORTANT TUCKING THE couplers to the couplers on the SHEET IN TOO TIGHTLY REDU
5. ToS EOI srie ERIEK EE EOE Eaa 9 Ronne Mainen ante setina enoi A NEAN trea eaeoedeananceaeny EEEE 9 Touple DOO prene E E EE A 10 Remtrns Tor oe VIOO serriroige etsii ENEA ERE E EERE 11 W a o E 11 Product o pecine ano N eonia ERE EESE EESE E aden 12 SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS a MEDICAL EQUIPMENT Aj IPX0 1 0 Indications Please read enclosed document thoroughly Declaration of Conformity to Medical Device Directive With respect to electrical shock fire and mechanical hazards only in accordance with ANSI AAMI ES60601 1 2005 3 ed and CAN CSA C22 2 No 60601 1 2008 International Electronics Approval Do not immerse power unit in liquid or spray liquids directly on power unit Type BF Equipment Indications This alternating pressure system with low air loss is designed to treat and prevent wounds by facilitating blood circulation and decreasing pressure of each tissue s contact area Always consult a physician or health professional before using this mattress system Contraindications This device is not indicated for treatment of certain patient conditions such as fracture of unstable vertebrae and illness of unstable vertebrae Always consult a physician or health professional before using this device The use of this system does not replace the regular repositioning monitoring and nursing of the patient 2 0 Safety Precautions 1 To ensure proper
6. and coverlet are completely dry before letting the patient lie on the surface again Do not use electric or tumble dryers Do not iron WARNING Always unplug the power unit before cleaning Routine cleaning of power unit can be done by wiping down with damp cloth using disinfectant or mild detergent Never spray liquids directly on the unit itself 11 0 Routine Maintenance Remove air filter from the rear panel of the power unit by opening up the filter cap Inspect the filter for dirt or dust and clean it with mild soap and water Reinsert the dried air filter after cleaning and ensure that the cap Is secure If replacement is needed contact H amp R Healthcare Only disinfected and dry systems should be stored Disconnect the air hoses from the power unit Roll up the mattress starting from the head end and working down toward the foot end Use the straps to secure It SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 12 0 Troubleshooting Check if power cord is Secure power cord into firmly plugged into both control unit and or 1 Power unit is not working the control unit and the electrical outlet electrical outlet Check if the power switch Turn power switch to ON is in the ON position position Check if power surge has A power surge may shut down the power overload the circuitry unit temporarily Turn the unit off and check the fuse for damage Turn the unit on again wi
7. is in lieu of all other warranties whether expressed or implied H amp R Healthcare nor any of its agents shall be held liable for consequential or incidental damages of any kind SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS Make sure all air cells are 15 0 Product Specifications Mattress Dimension 80 84 x 37 x 7 Number of Air Cells 20 Air Cells Power Control Unit Dimension SR366 11 5 x 8 5 x 4 5 Integrated Foam 2 Material Power Unit ABS fire retardant UL Mattress Cell 100 nylon with TPU lamination Coverlet 100 nylon quilted backing Power Input AC100 120V 60Hz 0 5A Power Consumption Normal Operation Max 15W Power Control Unit Weight 5 5 lbs Fuse Rating T1A 250 V Operating amp Transportation amp Storage Conditions Temperature 41 F 104 F Humidity 15 60 Electrical Classification Class Type BF Applied part is mattress IPXO do not immerse power unit in any liquid or spray any liquids directly on the power unit This system is not AP APG Protected Continuous operation Agency Approval ANSI AAMI ES60601 1 and CAN CSA C22 2 NO 60601 1 08 Electromagnetic Compatibility IEC60601 1 2 Maximum Weight Capacity 325 lbs H amp R Healthcare reserves the right to change prices or design parameters and specifications without incurring any liability in connection with such modifications SIG
8. operation please inspect and verify that all parts are set up properly and are anchored securely Do not place anything on top of the power unit Make sure power cord is underneath bed frame and does not pose a hazard 2 It is recommended to limit bed linens to a single layer in order to allow moisture to escape efficiently through the coverlet Breathable incontinent pads are recommended for use with this mattress system 3 Avoid using this device near open flames lighters or cigarettes Flammability hazard exists This device draws air from the surrounding environment Thus cigarette smoking may damage internal components 4 This system should be disinfected thoroughly between patients to avoid cross contamination 5 Verify that patient weight does not exceed the weight capacity of the bed frame bed rails or this mattress system SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 3 0 Warnings 1 Use this mattress with proper side rails to ensure that the gap between the side rail and the top of the mattress is not large enough to pose risk of head or neck entrapment Failure to do so could result in serious patient injury 2 DO NOT disassemble the power unit if you are not a qualified technician Please contact H amp R Healthcare for all service 3 This product is NOT AP APG protected 4 It is recommended that the patient be repositioned periodically while using this mattress 5
9. CES power unit THE EFFECTIVENESS OF THE SYSTEM Plug the power unit into an electrical outlet and turn on the 8 0 Patient Transfer main power rocker switch on the right side of the power unit and Transport Transfer It is recommended to have the mattress system at maximum weight setting during transfer Make sure the bed is secured before proceeding inflate the mattress system Please wait for approximately 30 seconds until the power unit is ready before making any program adjustments Wait approximately 30 minutes for the mattress to inflate fully anspor In the event of a patient transport two options are available 0 Program Settings 1 Detach the mattress air hose couplers from the power unit s quick release couplers and connect the two air hose couplers together to retain air in the mattress The mattress will stay inflated for approximately 2 hours depending on the patient s weight Place the patient in the center of the mattress Adjust the mattress internal pressure according to the patient weight by using the weight button on the control panel of the power unit If the mattress is too soft or too firm increase or decrease the mattress internal pressure one increment at a time and wait for the system to stabilize before making another change Continue this process until comfort is achieved 2 Unplug the power unit s power cord from the wall outlet and the mattress should stay
10. NA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS U 2 2201 30511 V1 0
11. SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS Operation Manual H amp R Healthcare 1750 Oak Street Lakewood NJ 08701 Phone 800 801 5533 Fax 732 367 623 1 www handrhealthcare com Congratulations and thank you for purchasing this Signa Relief Alternating Pressure System with Low Air Loss PLEASE READ THIS OPERATION MANUAL CAREFULLY BEFORE SETTING UP AND USING THE DEVICE Pay special attention to the warnings and other safety information Use of genuine manufacturer components is essential for optimal performance If you do not fully understand all the instructions safety precautions and warnings do not use this device If you have any questions or concerns please contact H amp R Healthcare at 800 801 5533 SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 2 Section Description Page CANNONS T E AS A EN EEN A OEO O TIE A I NE EET E EI AL Gy eC AUN Siete rated aes tc nner eioee swab E E E east cx E TEE ES NYY ATO E cua T vette ust ately sae biases ti duaaimueeiaautennahueauun 5 Oe MI AG ee cs crcentinds E E E 5 BS OUT EEEE PI PEIA IA T EE AA E EE A tele desea tse NET 6 Mattress and Power Unit InstallationsS ssessssenessersseseseeresusenessenssercsssererecceeserssersss 7 EO NS COU Scacchi cn n a a EA 8 Patient Transfer and Frais 0006 iasascgexccnticeninadcamosndddacesaadtaadiaadinaddansabesasesesedeseacseanbavecees 8 et Oy CPR Delati Olsene eee E EEE EEEE EEEE 9 Clean e
12. inflated for approximately 40 50 minutes This mattress system also has a safety foam base underneath the air cells to support the patient for a short period of time in case of deflation To resume normal operation please follow 7 0 Program Settings perform a hand check by placing their hands underneath patient s pelvis area to check if there is sufficient air support to ensure the patient is not bottoming out SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 8 9 0 Emergency CPR Deflation In case of emergency pull hard to remove the mattress CPR latch for emergency deflation and turn off the power unit by pressing the power mute button on the control panel at the same time The mattress will deflate from the weight of the patient To resume normal operation simply reinsert the CPR latch securely press the power mute button again and reset the patient weight 10 0 Cleaning Instruction Air mattress and power unit must be cleaned thoroughly between patients to avoid cross contamination The following is a suggested guideline Be sure to follow local infection control policies Regular cleaning can be performed at bedside with disinfectant followed by drying with a clean dry cloth Use only mild detergents to clean the coverlet and the mattress Any appropriate NON PHENOLIC cleaning agent may be used for heavy soiling from urine blood or other bodily fluids Please ensure that air mattress
13. th normal procedure Make sure there is no power failure Power unit does not Please contact H amp R respond to possible Healthcare for assistance solutions 2 Low Pressure alert Possible control failure Please contact H amp R does not turn off after 30 Healthcare for assistance seconds after the system is turned on 3 Alarm LED is lit during Check if there is leakage Please contact H amp R operation in air tubes or air cells Healthcare for assistance 4 Power unit is working Verify that CPR latch is Insert CPR latch securely but mattress replacement properly inserted is not inflating Check if mattress air Secure air hose couplers and or hose couplers are firmly into place Bottoming out is properly connected to occurring power unit s quick release couplers and or Verify that patient weight Increase or decrease Patient leaves a deep setting is correct weight setting until indentation at the appropriate pressure is contact area which does reached not return back to its Inspect air filter for dust Clean or replace air original shape filter SIGNA RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 10 Lift mattress coverlet up to check if air cells are properly linked to air connected correctly supply Check and adjust air tubes positions Lift mattress coverlet up to check if air tubes are kinked or obstructed Check if air cells are cut or cracked