Home

ENH710EXT User Manual - EnGenius Technologies, Inc.

image

Contents

1. Connect one end of the Ethernet cable into the main LAN port PoE of the Access Point and the other end to the AP Ethernet port on the PoE injector Connect the Power Adapter to the DC IN port of the PoE injector and plug the other end in to an electrical outlet Connect the second Ethernet cable into the LAN port of the PoE injector and the other end to the Ethernet port on the computer Screw on the provided antennas to the device Once both connections are secure verify the following a Ensure that the POWER light is on it will be green b Ensure that the 2 4 GHz 5 GHz WLAN light is on it will be green for both 5 GHz and 2 4 GHz c Ensure that the LAN Computer ENH710OEXT Connection light is on it will be green d Once all three lights are on proceed to set up the Access Point using the computer 15 This diagram depicts the hardware configuration em quami p PoE Injector PoE Swtich Ethernet Power Outlet Note The Access Point supports both IEEE 802 3at PoE Power over Ethernet or the included power injector You may use either one as the power source Do NOT use both at the same time Mounting the ENH 10EXT Using the provided hardware the ENH710OEXT can be attached to a wall or a pole 1 Wall Mount Kit 260x180x7 mm 2 Pole Mount Kit 140x112x33 mm 10 2 x 7 09 x 0 28 5 51 x 441 x 1 30 3 Pipe 63 5 D x 12 7 mm 4 Tool 20 D x 6 mm 5 Screws 6 5 D
2. Auth Key Specifies the authentication key Priv Protocol Selects the privacy protocol type DES Priv Key Specifies the privacy key for privacy Engine ID Specifies the engine ID for SNMPv3 Apply Save Click Apply Save to apply the changes CLI Settings CLI Setting CLI Enable SSH Setting SSH Disable HTTPS Setting Enable Disable HTTPS HTTPS forward CLI The Command Line Interface CLI allows you to type commands instead of choosing them from a menu or selecting an icon SSH Enable Secure Shell SSH to make secure encrypted connections in the network Secure Shell is a network protocol that allows data to be exchanged using a secure channel between two network devices HTTPS Enable HTTPS to transfer and display web content securely The Hypertext Transfer Protocol over SSL Secure Socket Layer is a TCP IP protocol used by web servers to transfer and display web content securely 5 Email Alert You can use the Email Alert feature to send messages to the configured email address when particular system events occur Note Do NOT use your personal email address as it can unnecessarily expose your personal email login credentials Use a separate email account made for this feature instead Email Alert Status 4 Enable From To Subject Email Alert ENH900EXT 00 02 6F FF FF FF Config Email Account Username Password SMTP Server Se
3. 5 GHza n frequencies Guest Network Settings SSID EnGenius 2 4GHz GuestNe EnGenius 5GHz GuestNetw Manual IP Settings IP Address Subnet Mask Automatic DHCP Server Settings Starting IP Address Ending IP Address WINS Server IP Enable Edit Security Suppressed SSID Station Separation Edit None d Edit None 7 192 168 200 100 192 168 200 200 0 0 0 0 SSID Specifies the SSID for the current profile Suppressed SSID Check this option to hide the SSID from clients If checked the SSID will not appear in the site survey Station Separation Click the appropriate radio button to allow or prevent communication between client devices IP Address The IP Address of this device Subnet Mask The IP Subnet mask of this device Starting IP Address The first IP Address in the range of the addresses by the DHCP server 47 Ending IP Address The last IP Address in the range of addresses assigned by the DHCP server Fast Handover Fast Handover O Enable Disable 70 Status RSSI dBm Range 60dBm 100dBm Fast Handover Enable the Fast Handover feature by ensuring that each client is served by at least one Access Point at any time Access Points continuously monitor the connectivity quality of any client in their range and efficiently share this information with other Access Points in the vincinity of that client to coordinate which of them should serve the client best RSSI Enter t
4. DHCP Client Disable Spanning Tree Protocol STP Disable e The Wireless LAN Information 2 4 GHz 5 GHz section shows wireless information such as Operating Mode Frequency and Channel Since the ENH710OEXT supports multiple SSIDs information about each SSID the ESSID and security settings are displayed Note Profile Settings are only applicable in Access Point and WDS AP modes Wireless LAN Information 2 4GHz Wireless LAN Information 5GHz Operation Mode AP Wireless Mode 802 11 A N Channel Bandwidth 40 MHz Channel 5 66 GHz Channel 132 Distance 1000 M Profile SSID Security 802 1Q H1 EnGenius063C97 1 5GHz None Disable 2 EnGenius063C97 2 5GHz None Disable H3 EnGenius063C97 3 5GHz None Disable 4 EnGenius063C97 4 5GHz None Disable H5 EnGenius063C97 5 5GHz None Disable 26 EnGenius063C97 6 5GHz None Disable 7 EnGenius063C97 7 5GHz None Disable 8 EnGenius063C97 8 5GHz None Disable Operation Mode AP Wireless Mode 802 11 B G N Channel Bandwidth 20 40 MHz Channel 2 437 GHz Channel 6 Distance 1000 M Profile SSID Security 802 1Q H1 EnGenius063C96 1 2 4GHz None Disable 2 EnGenius063C96 2 2 4GHz None Disable 3 EnGenius063C96 3 2 4GHz None Disable 4 EnGenius063C96 4 2 4GHz None Disable 5 EnGenius063C96 5 2 4GHz None Disable 26 EnGenius063C96 6 2 4GHz None Disable e The Statistics section shows Mac information such as 30 Connection 2 4 GHz 5 GHz Connection List 2 4 GHz 5 GHz WDS Link List Click th
5. automatically change from 802 1 1n to 802 118 Fast Roaming Enable Fast Roaming to serve mobile client devices that roam from Access Point to Access Point Some applications running on Client devices require fast re association when they roam to a different Access Point Voice application WDS Link Settings Using the WDS Wireless Distribution System feature will allow a network administrator or installer to connect to Access Points wirelessly Doing so will extend the wired infrastructure to locations where cabling is not possible or inefficient to implement Note Compatibility between different brands and models of Access Points is not guaranteed It is recommended that the WDS network be created using the same models for maximum compatibility Also note All Access Points in the WDS network need to use the same Channel and Security settings To create a WDS network please enter the MAC addresses of the Access Points that you want included in the WDS There can be a maximum of four Access Points Note Only applicable in WDS AP and WDS Bridge modes 45 2 4 GH2 5 GHz WDS Link Settings WDS Link Settings 2 4GHz Security None AES Passphrase om 8 63 ASCII characters or 64 hexadecimal digits ID MAC Address 1 2 3 4 WDS Link Settings 5GHz Security None AES Passphrase 8 63 ASCII characters or 64 hexadecimal digits Mode Disable
6. specify how often you wish to reboot the ENH710EXT Auto Reboot Setting Auto Reboot Status Disable D sunday Monday Tuesday Wednesday 0 10 Timer Auto Reboot Setting Enables or disables the Auto Reboot function Frequency of Auto Reboot Specifies how often you wish to reboot the ENH 10EXT by Min Hour Day or Week Timer Select the day and enter the time you would like to reboot automatically Save Click Save to apply the changes 54 Thursday Friday saturday Wi Fi Scheduler The Wi Fi Scheduler can be created for use in enforcing rules For example if you wish to restrict web access to Mon Fri from 3pm to 8pm you could create a schedule selecting Mon Tue Wed Thu and Fri while entering a Start time of 3pm and End Time of 8pm to limit access to these times Wi Fi Scheduler Enable NOTE Please assure that the Time Zone Settings is synced with your local time when enabling the Wi Fi Scheduler Wireless Radio 2 4GHZ y SSID Selection EnGenius063C96_1 2 4GHZy Schedule Templates Status Choose a template y Day Availability Duration Sunday available 00 00 24 00 Monday available 00 00 24 00 Shahi Tila Tuesday available 00 00 24 00 Wednesday available 00 00 24 00 Thursday available 00 00 24 00 Friday available 00 00 24 00 Saturday available 00 00 24 00 Status Enables or disab
7. the changes Logout Click Logout in Management menu to logout EnGenius ENH710EXT Overview Device Status Connections Network Basic Wireless Management Advanced Time Zone WiFi Scheduler Tools System Manager Account Firmware Log Device Information Device Name MAC Address LAN Wireless LAN 2 4GHz Wireless LAN 5GHz Country Current Local Time Firmware Version Management VLAN ID LAN Information IPv4 IP Address Subnet Mask Gateway Primary DNS Secondary DNS ENH710EXT 88 DC 96 06 3C 94 88 DC 96 06 3C 96 88 DC 96 06 3C 97 Default Wed Sep 25 08 30 55 UTC 2013 2 0 0 4096 192 168 1 1 255 255 255 0 192 168 1 1 0 0 0 0 0 0 0 0 Are you sure you want to logout 62 Reset In some circumstances it may be required to force the device to reboot Click on Reset to reboot the ENH710EXT EnGenius ENH710EXT 6 Overview Device Status Connections lt Network Basic Wireless ELT Advanced Time Zone WiFi Scheduler Tools Reset Device Information Device Name MAC Address LAN Wireless LAN 2 4GHz Wireless LAN 5GHz Country Current Local Time Firmware Version Management VLAN ID ENH710EXT 88 DC 96 06 3C 94 88 DC 96 06 3C 96 88 DC 96 06 3C 97 Default Wed Sep 25 08 30 55 UTC 2013 2 0 0 4096 The System Settings section allows you to reboot the device or restore the device to the factory default settings Restori
8. x 9 95 mm i 2 5 D x 0 5 0 79 D x 0 24 0 2 6 D x 0 39 MA ia gan To attach the ENH710EXT to a wall using wall mounting kit 1 Mark the four locations of the mounting holes on the flat mounting surface 2 Drill a 37 mm deep 8 mm hole in the markings and hammer the bolts into the openings e D ennen ae s Q ML aaa oS erg e D m d oe s 0 3 Place the lock and flat washers on the four hex cap screws and drive the screws to attach the bracket to the back of the Access Point 4 Tighten the flat washers to secure the bracket to the mounting surface To attach the ENH710EXT to a pole using the provided pole mounting kit 1 Place the lock and flat washers on the four hex cap screws tabs on the Pole Mount Bracket and drive the screws to attach the bracket to the back of 4 Lock and tighten the Pole Strap to secure the Pole Mount the Access Point Bracket to the pole 2 Drive the four round head screws to attach the Pole Mount Bracket to the bracket Note See diagram below for vertical and horizonal placements 3 Thread the open end of the Pole Strap through the two y ES KS ES QS E se 5 gt 0 KB ei vertical placement To install the ground cable on the ENH710EXT 1 Use the attached screws to pass the ground cable as 2 Assemble the ground cable on the device shown in the fi
9. 05600 Cesky Czech Jm no v robce t mto prohla uje Ze tento typ za zen je ve shod se z kladn mi po adavky a dal mi p slu n mi ustanoven mi sm rnice 1999 5 ES Dansk Danish Undertegnede fabrikantens navn erkl rer herved at f lgende udstyr udstyrets typebetegnelse overholder de v sentlige krav og vrige relevante krav i direktiv 1999 5 EF Deutsch German Hiermit erkl rt Name des Herstellers dass sich das Ger t Ger tetyp in Ubereinstimmung mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen der Richtlinie 1999 5 EG befindet Eesti Estonian K esolevaga kinnitab tootja nimi name of manufacturer seadme seadme t p type of equipment vastavust direktiivi 1999 5 EU p hin uetele ja nimetatud direktiivist tulenevatele teistele asjakohastele s tetele English Hereby name of manufacturer declares that this type of equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Espa ol Spanish Por medio de la presente nombre del fabricante declara que el clase de equipo cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE EAAnvikr Greek ME THN MAPOY2A name of manufacturer AHAONEI OTI type of equipment ZYMMOPQOONETAI MPO2 TI OY2IOAEI ANAITH2EIX KAITIZ AOIFTEX 2XETIKED AIATA EIX TH OAHTIA gt 1999 5 EK 66 Suomi Finnish
10. AC address table on this page Your choices are Disabled Deny MAC in the list or Allow MAC in the list MAC Address Enter the MAC address of the wireless client Add Click Add to add the MAC address to the MAC address table Delete Delete the selected entries Save Click Save to apply the changes Wireless Advanced Wireless Traffic Shaping Traffic shaping regulates the flow of packets leaving an interface to deliver improved Quality of Service Wireless Traffic Shaping Enable Traffic Shaping Disable 100 Mbps 1 999 100 Mbps 1 999 Download Limit Upload Limit Enable Traffic Shaping Check this option to enable Wireless Traffic Shaping Download Limit Specifies the wireless transmission speed used for downloading Upload Limit Specifies the wireless transmission speed used for uploading Save Click Save to confirm the changes 43 WPA PSK WPA Pre Shared Key Encryption Wireless Security 2 4G security Mode Encryption WPA2 PSK Both TKIP AES Passphrase Group Key Update Interval 3600 Encryption Select the WPA encryption type you would like Please ensure that your wireless clients use the same settings Passphrase Wireless clients must use the same Key to associate the device If using ASCII format the Key must be from 8 to 63 characters in length If using HEX format the Key must be 64 HEX characters in length Group Key Update Interval Specifies how of
11. Disable y Disable x Disable y ID MAC Address 4 2 3 4 Security Select None or AES from the drop down list AES Passphrase Enter the Key Values you wish to use Other Access Points must use the same Key to establish a WDS link MAC Address Enter the Access Points MAC address to where you want to extend the wireless area Mode Select to disable or enable from the drop down list Save Click Save to confirm the changes Client Bridge Setting Wireless Settings 2 4GHz i MM a A Security Mode Select the correct security mode and AP SSID AP SSID Edi None insert the correct encryption type Please refer the wireless security section in page 42 No Display the setting value Save Click Save to accept the changes SSID You can implement the AP detection to select the c proper SSID Edit Click it to implement the advanced settings Wireless Setting 2 4GHz Frefered BSSID SSID AP SSID Wireless Security 2 4GHz security Mode Save Prefer BSSID You can insert the prefer BSSID or enter the specific SSID to be associated with the Access Point SSID You can implement the AP detection to select the proper SSID 46 Guest Network Settings Adding a guest network allows visitors to use the Internet without giving out your office or company wireless security key You can add a guest network to each wireless network in the 2 4 GHzb g n and
12. E ow e 24 WDS AP Mode The ENH710EXT also supports WDS AP mode This operating mode allows wireless connections to the ENH710OEXT using WDS technology In this mode configure the MAC addresses in both Access Points to enlarge the wireless area by enabling WDS Link settings WDS supports up to four 4 AP MAC addresses WDS Bridge Mode In WDS Bridge Mode the ENH710EXT can wirelessly connect different LANs by configuring the MAC address and security settings of each ENH710EXT device Use this mode when two wired LANs located a small distance apart want to communicate with each other The best solution is to use the ENH710EXT to wirelessly connect two wired LANs as shown in the following diagram WDS Bridge Mode can establish up to four WDS links creating a star like network Note WDS Bridge Mode does not act as an Access Point Access Points linked by WDS are using the same frequency channel More Access Points connected together may lower throughput This configuration can be susceptible to generate endless network loops in your network so it is recommended to enable the Spanning Tree function to prevent this from happening R7 7 n 26 WDS Station Mode Station mode expands the WDS by receiving a wireless signal service and sharing it through the Ethernet port E J R7 I lI Chapter 5 ea Main Status Save Changes This page lets you save and apply the settings shown under Unsav
13. EnGenius Business Solutions User Manual em ENH710EXT version 1 0 Dual Band Long Range Wireless NOOO Outdoor Access Point IMPORTANT To Install this Access Point please refer to the Quick Installation Guide included in the product packaging Table of Contents Chapter 1 Product Overview enne 4 Key Features Introduction ns 5 System REGUIFCMENTUS sentada acia 6 Package Comte MiS iaa Technical Specifications nnn 8 lech ele iman riada 10 Chapter 2 Before You Begin eere 11 Computer le nana 12 Hardware Installation ss 15 Mounting the ENH TOEXTN enn 16 Chapter 3 Configuring Your Access Point 20 Default Settings Web Configuration 21 Chapter 4 Building a Wireless Network 22 ACCESS PONT MO ran 23 Client Bridge Modes area 24 WDS AP Mod anda ana cd rtr 25 WDS Bridee Modan 26 W DS STATION MOG EE 21 Chapter 5 E TEE 28 Mal Stata aora 29 COMEN ais OT 31 Chapter 6 Network nnnm 33 Basic IP Serisi a 34 Spanning Tree Protocol Setting 35 Chapter 7 2 4 GHz 5 GHz Wireless 36 WIFeleSSSQPEIPBS riada 3 2 4 GH2 5 GHz Wireless Network e 38 LARZ GHZ SSID PLOMB usa 40 Wireless Sec Ub ee Eeer 41 Wireless MAC ett 42 Wireless Advanced eene 43 WPS Mixed Enterprise AP WDS AP Mode nn 44 WDS UNK SEINES mats ridi oti ac 45 Client Bridge Settings nnne 46 Guest Ne
14. Genius063C97 1 5GHz EnGenius063C97 2 5GHz EnGenius063C97 3 5GHz EnGenius063C97 4 5GHz EnGenius063C97 5 5GHz EnGenius063C97 6 5GHz EnGenius063C97 5GHz EnGenius063C97 8 5GHz D C On A N a Suppressed Station SSID Separation Suppressed Station SSID Separation Isolation VID Isolation oO N C Cn A N 40 Current Profile You can configure up to sixteen 16 different SSIDs eight 8 per band If multiple client devices will be accessing the network you can arrange the devices into SSID groups Click Edit to configure the profile and check whether you want to enable extra SSID SSID Specifies the SSID for the current profile Suppressed SSID Check this option to hide the SSID from clients If checked the SSID will not appear in the site survey Station Separation Click the appropriate radio button to allow or prevent communication between client devices VID Specifies the VLAN tag for each profile If your netowrk includes VLANs you can specify a VLAN ID for packets pass through the Access Point with a tag Wireless Security See the Wireless Security section Isolation Restrict clients communicating with different VIDs by selecting the radio button Save Click Save to accept the changes Wireless Security The Wireless Security section lets you configure the ENH710EXT s security modes WEP WPA PSK WPA2 PSK WPA PSK Mixed WPA WPA2 and WPA Mixed It is strongly reco
15. Par la pr sente nom du fabricant d clare que l appareil type d appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Con la presente nome del costruttore dichiara che questo tipo di apparecchio conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Ar o name of manufacturer izgatavotaja nosaukums deklare ka type of equipment iekartas tips atbilst Direktivas 1999 5 EK b tiskaj m pras b m un citiem ar to saist tajiem noteikumiem Siuo manufacturer name deklaruoja kad Sis equipment type atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas Hierbij verklaart naam van de fabrikant dat het toestel type van toestel in overeenstemming is met de essenti le eisen en de andere relevante bepalingen van richtlijn 1999 5 EG Hawnhekk isem tal manifattur jiddikjara li dan il mudeltal prodott jikkonforma mal htidijietessenzjaliu ma provvedimenti ohrajn relevanti li hemm fid Dirrettiva 1999 5 EC Alul rott gy rt neve nyilatkozom hogy a tious megfelel a vonatkoz alapvet k vetelm nyeknek s az 1999 5 EC ir nyelv egy b el r sainak Niniejszym nazwa producenta o wiadcza ze nazwa wyrobu jest zgodny z zasadniczymi wymogami oraz pozostalymi stosownymi postanowieniami Dyrektywy 1999 5 EC Nome do fabricante declara que este tipo de equipamento est conforme c
16. affic shaping The ENH710EXT also supports wireless encryption including Wi Fi Protected Access WPA PSK WPA2 PSK Encryption and IEEE 802 1X with RADIUS System Requirements The following are the Minimum System Requirements in order to configure the device e Computer with an Ethernet interface or wireless network capability e Windows OS XP Vista 7 8 MacOS or Linux based operating systems e Web Browsing Application i e Internet Explorer Firefox Safari or another similar browser application Package Contents The ENH710EXT package contains the following items e ENH710EXT Access Point e 2 detachable 5 dBi 2 4 GHz Omni directional Antenna e 2 detachable 7 dBi 5 GHz Omni directional Antenna e Power Adapter e PoE Injector EPE 48GR e Grounding Cable e Pole Mount Bracket e Wall Mount Base e Mounting Screw Set e Quick Installation Guide all ttems must be in package to issue a refund Technical Specifications Standard IEEE802 11a n on 5 GHz IEEE802 1 1b g n on 2 4 GHz IEEES02 3at Antenna 4 External N type Antennas 2 x detachable 5dBi 2 4GHz Omni directional Antennas 2 X detachable 7dBi 5GHz Omni directional Antennas Physical Interface 2 x 10 100 1000 Gigabit Ethernet Port with PoE support LAN1 Port supports IEEE802 3at PoE Input LED Indicator Power LAN 1 LAN 2 2 4 GHz 5 GHz Power Requirements External Power Adapter DC IN 48V 0 5A IEEE802 3at support Operation Modes Access P
17. ariety of outdoor environments Its high powered long range characteristics make it a cost effective alternative to ordinary Access Points that don t have the range and reach to connect to a growing number of wireless users who wish to connect to a business network The ENH710EXT supports the 2 4 GHz frequency band under 802 11 b g n mode while at the same time providing the 5 GHz band for communicating to and from other 5 GHz capable computers tablets or smart phones or transferring files Several ENH710EXTs can be deployed in a campus setting using the 5 GHz band as Maximum data rates are based on IEEE 802 11 standards Actual throughput and range may vary depending on many factors including environmental conditions distance between devices radio interference in the operating environment and mix of devices in the network Features and specifications subject to change without notice Trademarks and registered trademarks are the property of their respective owners For United States of America Copyright O 2014 EnGenius Technologies Inc All rights reserved a backhaul to provide multiple 2 4 GHz wireless cells for computers or mobile devices in common outdoor areas The ENH710EXT Is easy to install in virtually any location with its included PoE Power over Ethernet injector for quick outdoor installation The ENH710EXT enables network administrators to control its transmit power and features settings for selecting narrow bandwidth and tr
18. clients to the 5 GHz band where 802 11b g clients cannot go and leave 802 11b g clients in 2 4GHz to operate at their slower rates Band Steering works within the Access Point by directing 5 GHz capable clients to that band Save Click Save to confirm the changes 3 This page displays the current status of the Wireless settings of the ENH710EXT 2 4 GHz 5 GHz Wireless Network 2 4GHZ 9GHZ v Green w Access Point vw FE Green G 802 11 AN vw 40 MHz Operation Mode Client Bridge Wireless Mode 802 11 B G N vw Channel HT Mode Extension Channel Channel Auto Transmit Power Data Rate RTS CTS Threshold 1 2346 Client Limits Auto 2346 v Auto v 2346 O Enable Disable Enable Disable 32 Frames 50000 Bytes Max 0 6miles 1 Enable O Enable O Disable 32 50000 AP Detection Distance 1 30km 1 Disable Aggregation Bytes Max 0 6miles Operation Mode Select Operation Mode The ENH220EXT supports multi operation modes Access Point Client Bridge or WDS WDS AP WDS Bridge and WDS Station Wireless Mode Supports 802 11b g n mixed mode in 2 4 GHz and 802 11a n mixed mode in 5 GHz Channel HT Mode The default channel bandwidth is 20 MHz 40 MHz The larger the channel the greater the transmission quality and speed 38 Extension Channel Select the upper or lower channel Your selection may affect the Auto channel function Channel Select the approriate chann
19. curity Mode Send Test Mail From Enter the email address to show the sender of the emall To Enter the address that you wish to send emails to Subject Enter the text that you wish to appear in the email s subject line Username Enter the username for the email account that will be used to send emails Password Enter the password for the email account that will be used to send emails SMTP Server Enter the IP address or hostname of the outgoing SMTP server Port Enter the SMTP port number to use for outbound emalils 52 Time Zone Time Setting This page allows you to set the internal clock of the ENH710EXT Date and Time Settings Manually Set Date and Time Date 2013 09 25 Time 08 10 24 Hour Synchronize with PC Automatically Get Date and Time NTP Server 209 81 9 7 Time Zone Time Zone UTC 00 00 Gambia Liberia Morocco Enable Daylight Saving Start January Manually Set Date and Time Manually specify the date and time Automatically Get Date and Time Select and check whether you wish to enter the IP address of an NTP server or use the default NTP server to have the internal clock set automatically Enable Daylight Saving Check whether daylight savings applies to your area 53 Start Select the day month and time when daylight savings time starts End Select the day month and time when daylight sav ings times ends Auto Reboot Settings You can
20. d Settings SNMP Settings This page allows you to assign the Contact Details Location Community Name and Trap Settings for a Simple Network Management Protocol SNMP SNMP is a networking management protocol used to monitor network attached devices SNMP allows messages called protocol data units to be sent to various parts of the network Upon receiving these messages SNMP compatible devices called agents returns the data stored in their Management Information Bases SNMP Settings Status Community Name Read Only Community Name Read Write public private 162 public Enable admin MD5 12345678 DES y 12345678 1 31 Characters 8 32 Characters 8 32 Characters SNMP Enable Disable Enables or disables the SNMP feature Contact Specifies the contact details of the device 50 Location Specifies the location of the device Community Name Read Only Specifies the password for the SNMP community for read only access Community Name Read Write Specifies the password for the SNMP community with read write access Trap Destination Address Specifies the IP address of the computer that will receive the SNMP traps Trap Destination Community Name Specifies the password for the SNMP trap community SNMPv3 Enables or disables the SNMPv3 feature User Name Specifies the username for SNMPv3 Auth Protocol Selects the authentication protocol type MDS or SHA
21. d entry box Verify Password Re enter the new password in the Confirm Password entry box for confirmation Apply Click Apply to apply the changes 58 Firmware Firmware Upgrade This page allows you to upgrade the firmware of the ENH710OEXT Firmware Upgrade Current Firmware Version 2 0 0 Select the new firmware from your hard disk Browse No file selected Upload To Perform the Firmware Upgrade 1 Click the Choose File button and navigate the OS file system to the location of the upgrade file Select the upgrade file The name of the file will appear in the Upgrade File field Click the Upload button to commence the firmware upgrade Note The device is unavailable during the Firmware upgrade process and must restart when the upgrade is completed Any connections to or through the device will be lost Backup Restore Backup Restore Settings Factory Setting Backup Setting Export Restore New Setting Reset to Default User Setting Reset Back Up Setting as Default Backup Restore to User Default Restore Factory Setting The function allows you to export the current device configurations When you export your configurations you also can reload the saved configurations into the device through the Restore Saved Settings from a file section If extreme problems occur or if you have set the ENH710EXT incorrectly you can use the Reset button in the Revert to Facto
22. dars could cause interference and or damage to LE LAN devices Avertissement De plus les utilisateurs devraient aussi tre avis s que les utilisateurs de radars de haute puissance sont d sign s utilisateurs principaux c d qu ils ont la priorit pour les bandes 5250 5350 MHz et 5650 5850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL IMPORTANT NOTE Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body D claration d exposition aux radiations Cet quipement est conforme aux limites d exposition aux rayonnements IC tablies pour un environnement non contr l Cet quipement doit tre install et utilis avec un minimum de 20cm de distance entre la source de rayonnement et votre corps 68 Appendix D Professional Installation Instruction Installation Personal This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge The general user shall not attempt to install or change the setting Installation Location The product shall be installed at a location where the radiating antenna can be kept 20cm from nearby person in normal operation condition to meet regulatory RF exposure requirement Externa
23. e Access Point ensure you enter the correct IP Address vane Fema Version 200 Management VLAN ID 4096 New Tab LAN Information IPv4 IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Primary DNS 0 0 0 0 Secondary DNS 0 0 0 0 DHCP Client Disable 2 Chapter 4 Building a Wireless Network The ENH710EXT has the ability to operate in various modes This chapter describes the operating modes of the ENH710EXT Access Point Mode In Access Point Mode ENH710EXT behaves likes a central connection for stations or clients that support IEEE 802 1 1a b g n networks The stations and clients must be configured to use the same SSID Service Set Identifier and security password to associate with the ENH7 10EXT The ENH710OEXT supports up to eight 8 SSIDs per band at the same time for secure access w O AS CS CNN s 23 Client Bridge Mode The ENH710EXT essentially acts as a wireless adapter that connects to an access point to allow a system of wireless access to the network in the Client Bridge mode Since the computers are on the same subnet the ENH710EXT can broadcast to reach all end devices If you use the client bridge mode in the ENH710OEXT you can use the AP Detection feature to scan for Access Points within range When you find an Access Point configure the ENH710EXT to use the same SSID and Security Password as the Access Point to associate with it L2 EnGeniu E
24. e connection link under the Overview menu displays theconnectionlistof clients associated to the ENH710EXT s 2 4 GHz 5 GHz along with the MAC addresses and signal strength for each client Clicking Refresh updates the Click the connection link under the Overview menu This page displays the current status of the WDS link including WDS Link ID MAC Address Link Status and RSSI Note Only applicable in WDS AP and WDS Bridge modes client list Note Only applicable in Access Point and WDS AP modes Overview Connection List 2 4GHz SSID MAC Address TX RX RSSI Block Device Status SNWL EC 55 F9 4C D9 EA 227782Kb 59705Kb 57dBm Kick Connections SNWL 54 72 4F 66 89 42 323Kb 190Kb 43dBm Kick lt Network ep SNWL 60 FA CD 6E 93 0B 2556Kb 1209Kb 50dBm Kick asic me SNWL 60 36 DD 7F 3A 05 62466Kb 6127Kb A7dBm Kick Ireless TE SNWL 48 60 BC 5E 8C DF 1011Kb 191Kb 52dBm Kick 5 SNWL E8 2A EA 05 72 79 78334Kb 8725Kb 38dBm Kick een deiere SNWL 20 A2 E4 23 41 63 255Kb 76Kb 52dBm Kick oo EAP900H 2 4GHz 08 ED B9 E1 FD CF 159346Kb 19451Kb 61dBm Kick ee EAP900H 2 4GHz C8 6F 1D 1B F4 BE 3563Kb 582Kb 61dBm Kick WiFi Scheduler M EAP900H 2 4GHz 20 02 AF C5 6D 85 1731Kb 504Kb 46dBm Kick Tuo EAP900H 2 4GHz 54 26 96 CF F2 4D 152054Kb 5003Kb 50dBm Kick 2 System Manager Account Firmware Connection List 5GHz Log SSID MAC Address TX RX RSSI Block SNWL 5G 7C 7A 91 52 01 9D 216449Kb 47456Kb 49dBm Kick 3 Client Bridge Connection S
25. echniques Harmonized EN covering essential requirements under article 32 of the R amp TTE Directive e EN 301 893 Broadband Radio Access Networks BRAN 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3 2 of the R amp TTE Directive e EN 301 489 1 Electromagnetic compatibility and Radio Spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 1 Common technical requirements e EN 301 489 17 Electromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 17 Specific conditions for 2 4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment 65 This device is a 5GHz wideband transmission system transceiver intended for use in all EU member states and EFTA countries except in France and Italy where restrictive use applies In Italy the end user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and or for supplying public access to telecommunications and or network services This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 2483 5 MHz For detailed information the end user should contact the national spectrum authority in France C
26. ed changes list or cancel the unsaved changes and revert to the previous settings that were in effect Unsaved Unsaved changes list network lan dns 0 0 0 0 0 0 0 0 network lan ipaddr 192 168 1 2 network lan accept ra Apply Save 29 Device Status Clicking the Device Status link under the Overview menu shows the status information about the current operating mode e The Device Information section shows general system information such as Device Name MAC Address Current Time Firmware Version and Management VLAN ID Note VLAN ID information is only applicable in Access Point or WDS AP mode Device Information Device Name ENH710EXT MAC Address LAN 00 02 6F 22 0A 00 Wireless LAN 2 4GHz 00 02 6F 22 0A 01 Wireless LAN 5GHz 00 02 6F 22 0A 02 Country Default Current Local Time Fri Oct 3 08 01 39 UTC 2014 Firmware Version 2 0 7 Management VLAN ID Untagged e The LAN Information section shows the Local Area SSID MAC address RX and TX Network settings such as the LAN IP Address Subnet mask and DNS Address Statistics SSID MAC RX Packets TX Packets Ethernet 00 02 6F FF FF FF 75 57KB 856 PKts 455 926KB 399 PKts EnGenius063C96 1 24GHz 88 DC 96 06 3C 96 OKB 0 PKts 0 792KB 4 PKts EnGenius063C97 1 5GHz 88 DC 96 06 3C 97 OKB 0 PKts OKB 0 PKts LAN Information IPv4 IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Primary DNS 0 0 0 0 Secondary DNS 0 0 0 0
27. el and frequency Select Auto to enable auto channel selection Transmit Power Sets the power output of the wireless signal Data Rate Select a data rate from the drop down list The data rate affects throughput of data in the ENH710EXT Select the best balance for you and your network but note that the lower the data rate the lower the throughput though transmission distance is also lowered RTS CTS Threshold Specifies the threshold package size for RTC CTS A small number causes RTS CTS packets to be sent more often and consumes more bandwidth Client Limits Limits the total number of clients Aggregation Merges data packets into one packet This option reduces the number of packets but also increases packet sizes AP Detection AP Detection can select the best channel to use by scanning nearby areas for Access Points Distance Specifies the distance between Access Points and clients Note that longer distances may drop higher speed connections Save Click Save to confirm the changes or Cancel to cancel and return to previous settings 39 2 4 GHz 5 GHz SSID Profile Wireless Settings 2 4GHz No Enable SSID i Security d EnGenius063C96 1 2 4GHz EnGenius063C96 2 2 4GHz EnGenius063C96 3 2 4GHz EnGenius063C96 4 2 4GHz EnGenius063C96 5 2 4GHz EnGenius063C96 6 2 4GHz EnGenius063C96 7 2 4GHz EnGenius063C96 8 2 4GHz 1 2 3 4 5 6 T 8 Wireless Settings 5GHz No Enable SSID Security d En
28. gure below FAN gt amp LE e 2 nf o ru PH Q LE T 7 A mes mr A Hs Se ae AL i npe e P A AN E KH EH GER KH 3 E j E E C E Uk 532525222573 ew e 1 H A S e f Length 1 8m 5 9 Chapter 3 Configuring Your Access Point Configuring Your Access Point This section will show you how to configure the device 2 The default username and password are admin using the web based configuration interface Once you have entered the correct username and password click the Login button to open the web base Default Settings configuration page Please use your Ethernet port or wireless network adapter to connect the Access Point TT ESS 192 169 1 1 II IA ES OUR admin admin ENH 10EXT Web Configuration 1 Open a web browser Internet Explorer Firefox Safari 3 If successful you will be logged in and see the Chrome and enter the IP Address http 192 168 1 1 ENH710OEXT User Interface EnGenius ENH710EXT e 319216811 Device Information Device Name ENH710EXT MAC Address LAN 88 DC 96 06 3C 94 Wireless LAN 2 4GHz 88 DC 96 06 3C 96 a asic Wireless LAN 5GHz 88 DC 96 06 3C 97 Note If you have changed the default LAN IP Address of zA E Current Local Time Wed Sep 25 03 04 37 UTC 2013 th
29. he RSSI Received Signal Strength Index in order to determine the handover procedure which the current wireless link will terminate RSSI is an indication of the power level being received by the antenna Therefore the higher the RSSI number the stronger the signal Chapter 8 Management Management VLAN Settings This page allows you to assign a VLAN tag to packets sent over the network A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network LAN Computers on VLAN do not have to be physically located next to one another on the LAN Note Only applicable in Access Point and WDS AP modes Management VLAN Settings CAUTION If you reconfigure the Management VLAN ID you may lose connectivity to the access point Verify that the switch and DHCP server can support the reconfigured VLAN ID and then re connect to the new IP address Management VLAN Enable el 4096 49 Management VLAN If your network includes VLANs you can enable Management VLAN ID for packets passing through the Access Point with a tag Save Click Save to confirm the changes or Cancel to cancel and return to previous settings Note If you reconfigure the Management VLAN ID you may lose your connection to the ENH710EXT Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the ENH710EXT using the new IP address Advance
30. l Antenna Use only the antennas which have been approved by the applicant The non approved antenna s may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC IC limit and is prohibited Installation Procedure Please refer to user s manual for the detail Warning Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules The violation of the rule could lead to serious federal penalty 69 Appendix Instructions d installation professionnelle Installation CCe produit est destine a un usage specifique et doit etre installe par un personnel qualifie maitrisantles radiofrequences etles regles s y rapportant l installation et les reglages ne doivent pas etre modifies par l utilisateur final final Emplacement d installation En usage normal afin de respecter les exigences reglementaires concernant l exposition aux radiofrequences ce produit doit etre installe de facon a respecter une distance de 20cm entre l antenne emettrice et les personnes Antenn externe Utiliser uniiquement les antennes approuvees par le fabricant L utilisation d autres antennes peut conduire a un niveau de rayonnement essentiel ou non essentiel depassant les niveaux limites definis par FCC IC ce qui est interdit Procedure d installation Consulter le manuel d utilisation Avertissement Choisir avec soin
31. la position d installation et s assurer que la puissance de sortie ne depasse pas les limites en vigueur La violation de cette regle peut conduire a de serieuses penalites federales 0 Appendix f Detachable Antenna Usage This device has been designed to operate with an antenna having a maximum gain of 7 dB Antenna having a higher gain is strictly prohibited per regulations of Industry Canada The required antenna impedance is 50 ohms Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter IC 10103A ENH710EXT Model ENH710EXT has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Ce dispositif a t concu pour fonctionner avec une antenne ayant un gain maximal de dB 7 Une antenne a gain plus lev est strictement interdite par les r glements d Industrie Canada L imp dance d antenne req
32. les the Wi Fi scheduler function Wireless Radio Select 2 4 GHz or 5 GHz from the drop down list for the preferred band type SSID Selection Select a SSID from the drop down list Schedule Templates Select a schedule template from the 55 drop down list Day s Place a checkmark in the boxes for the desired days or select the All Week radio button to select all seven days of the week Duration The Start Time is entered in two fields The first box is for hours and the second box is for minutes The End Time is entered in the same format as the Start time Tools Ping Test Parameters This page allows you to analyze the connection quality of the ENH TOEXT and trace the routing table to a target in the network Ping Test Parameters Target IP Domain Name Ping Packet Size 64 Bytes Number of Pings Start Traceroute Test Parameters Target IP Domain Name Start Stop Target IP Enter the IP address you would like to search Ping Packet Size Enter the packet size of each ping Number of Pings Enter the number of times you wish to ping 56 Start Ping Click Start Ping to begin pinging the target device via IP Traceroute Target Enter the IP address or domain name you wish to trace Start Traceroute Click Start Traceroute to begin the trace route operation Speed Test Parameters LED Control This page allows you to control LED on off for Power LAN in
33. mmend that you use WPA2 PSK Wireless Security 2 4G Security Mode Auth Type Input Type WEP Open System y Hex 40 64 bit 10 hex digits or 5 ASCII char Iz Key Length Default Key Key1 Key2 Key3 Key4 41 Auth Type Select Open System or Shared Key Input Type ASCII Regular Text recommended Hexadecimal Numbers For advanced users Key Length Select the desired option and ensure that wireless clients use the same setting Your choices are 64 128 and 152 bit password lengths Default Key Select the Key you wish to be the default Transmitted data is ALWAYS encrypted using the Default Key the other Keys are for decryption only You must enter a Key Value for the Default Key Encryption Key Number Enter the Key Value or values you wish to use Only the Key selected as Default is required The others are optional Wireless MAC Filtering Wireless MAC Filtering is used to allow or deny network access to wireless clients computers tablet PCs NAS smartphones etc according to their MAC addresses You can manually add a MAC address to restrict permission to access the ENH710EXT The default setting is Disable Wireless MAC Filter Note Only applicable in Access Point and WDS AP modes Wireless MAC Filter ACL Mode Disabled MAC Address 42 ACL Mode Determines whether network access is granted or denied to clients whose MAC addresses appear in the M
34. n DNS server address automatically Use the following DNS server addresses Preferred DNS server Validate settings upon exit 13 Apple Mac OS X 1 Go to System Preferences Which can be opened in the Applications folder or selecting it in the Apple Menu 2 Select Network in the Internet amp Network section eo System Preferences 4 Show All Personal che m E Uu o Appearance Desktop amp Screen Saver Hardware Bluetooth CDs amp DVDs Internet amp Mert Network System 3 Highlight Ethernet Dock Displays QuickTime Expos amp International Securi Spaces Energy Keyboard amp Print amp Saver Mouse EOJ Sharing In Configure IPv4 select Manually Enteran IP address thatis different from the ENH710EXT and Subnet mask then press OK Note Ensure that the IP address and Subnet mask are on the same subnet as the device For example ENH710EXT IP address 192 168 1 1 PClPaddress 192 168 1 2 192 168 1 255 PC Subnet mask 255 255 255 0 Click Apply when done eoc a show all Location Automatic Network t atus Connected Ethernet is currently active and has the IP address 192 168 1 100 Configure IPv4 Manually IP Address 192 168 1 100 Subnet Mask 255 255 255 0 Router DNS Server Search Domains SG H id Click the lock to prevent further changes Hardware Installation
35. ng the unit to the factory default settings will erase all settings including any rules you have created System Commands Reboot the Device Restore to Factory Defaults Appendix 63 Appendix A Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help ay FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority
36. oint Client Bridge WDS WDS Detail WDS AP WDS Bridge WDS Station Optimal Performance Distance Control Ack Timeout Multicast Supported Band Steering Fast Roaming Auto Channel Selection BSSID Support Easily Management VLAN Tag VLAN Pass through Guest Network QoS Complaint with IEEE 802 1 1e WMM RADIUS Accounting Wireless STA Client connection list Traffic Shaping Per SSID Per user Intuitive Tools SNMP v1 v2c v3 support MIB I II Private MIB Save Configuration as Default CLI Support WiFi Scheduler Auto Reboot E mail Alert Reinforcement Security WEP Encryption 64 128 152 bit WPA WPA2 Enterprise WPA EAP using TKIP or AES Hide SSID in beacons MAC address filtering up to 32 MACS per SSID Https Support SSH QoS Quality of Service Complaint with IEEE 802 11e standard Physical Environment Conditions Operating Temperature 4 F to 158 F 20 C to 0 C Humidity non condensing 9096 or less Storage Temperature 22 F to 176 F 30 C to 80 C Humidity non condensing 9096 or less Physical Interface Dimensions and Weights Length 280 48mm 1 1 22 Width 217 65mm 8 58 Depth 55 50mm 2 1 Weight 1 88Kg 4 17 lbs em q 1 2 4 GHz Antennas Detachable 5 dBi 2 4 GHz Omni directional 2 5 GHz Antennas Detachable 7 dBi 5 GHz Omni directional 3 LAN Port 1 802 3at PoE Input Ethernet port for RJ 45 cable 4 LAN Port 2 Ethernet port for RJ 45 cable Chap
37. om os requisitos essenciais e outras disposi es da Directiva 1999 5 CE Ime proizvajalca izjavlja da je ta tip opreme v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo ili direktive 1999 SES Meno v robcu t mto vyhlasuje Ze typ zariadenia spl a z kladn po iadavky a v etky pr slu n ustanovenia Smernice IONES Valmistaja manufacturer vakuuttaa t ten ett type of equipment laitteen tyyppimerkinta tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen 6 Appendix C IC Interference Statement Industry Canada statement This device complies with RSS 210 of the Industry Canada Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Ce dispositif est conforme la norme CNR 210 d Industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivantes 1 le dispositif ne doit pas produire de brouillage pr judiciable et 2 ce dispositif doit accepter tout brouillage recu y compris un brouillage susceptible de provoquer un fonctionnement ind sirable IC Caution High power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these ra
38. rnet section then select Change adapter settings d E Choose homegroup and sharing options Control Panel Home Change adapter settings Change advanced sharing settings Network and Internet View network status and tasks 12 3 Rightclickon Local Area Connection andselectProperties 5 Select Use the following IP address and enter an IP address that is different from the ENH71OEXTand Subnet por mask then click OK Connection N Note Ensure that the IP address and Subnet mask are Repair on the same subnet as the device Bridge Connections For example ENH710EXT IP address 192 168 1 1 Create Shortcut uc PCIP address 192 168 1 2 192 168 1 255 Properties PC Subnet mask 255 255 255 0 4 Select Internet Protocol Version 4 TCP IPv4 and then select Properties Internet Protocol Version 4 TCP IPv4 Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings DE Client for Microsoft Networks M Blos Packet Scheduler M a File and Printer Sharing for Microsoft Networks M A Intemet Protocol Version 6 TCP IPv6 Obtain an IP address automatically IP address 192 168 1 10 Subnet mask 255 255 255 0 Default gateway wi A Link Layer Topology Discovery Mapper 1 0 Driver v 4 Link Layer Topology Discovery Responder Obtai
39. ry Default Settings section to restore all the configurations of the ENH710EXT to the original default settings r 59 Browse No file selected Backup Setting Click Export to save the current configured settings Restore New Setting To restore settings that have been previously backed up click Browse select the file and click Restore Restore to Default Click Reset button to restore the ENH710EXT to its factory default settings User Setting The function allows you to backup the current device configurations into the ENH710EXT as the default value If extreme problems occur or if you have set the ENH 10OEXT incorrectly you can push the Reset button to revert all the configurations of the ENH710EXT to the user default Back Up Setting as Default Click Backup to backup the user settings you would like to the device s memory for the default settings Restore to User Default Click Restore to restore user settings to the factory standard settings Note1 After setting the current settings as the default you should click the Restore to Default on the web interface for reverting the settings into the factory default instead of pushing the reset button Note2 Please write down your account and password before saving The user settings will now become the new default settings at the next successful login 60 Log System Log The ENH710EXT automatically logs records events of possible interest in Its in
40. tatus Click the connection link under the Overview menu This page displays the connection status between Access Point including associated SSID BSSID connection status wireless mode current channel security Tx Data Rate Mbps Current noise level and signal strength 32 Chapter 6 Network 33 Basic IP Settings IPv4 IPv6 Settings This page allows you to modify the device s IP settings IP Network Settings Select whether the device IP address will use a static IP address specified in the IP address field IPv Settings E or be obtained automatically when the device connects to IP Network Setting Static IP IP Address 192 168 1 1 a DHCP Server mar ONS 0000 IP Address The IP address of this device Secondary DNS 0 0 0 0 Subnet Mask The IP Subnet mask of this device IPv6 Settings d Link local Address as Gateway The Default Gateway of this device Leave it Gateway Primary DNS blank if you are unsure of this setting Primary Secondary DNS The primary secondary DNS address for this device Save Click Save to confirm the changes 34 Spanning Tree Protocol STP Settings This page allows you to modify the Spanning Tree settings Enabling the Spanning Tree protocol will prevent network loops in your LAN network Spanning Tree Protocol STP Settings Status Hello Time Disable y 2 seconds 1 10 seconds 6 40 seconds 4 30 0 65535 Max Age Forward Delay Priori
41. ten in seconds the Group Key changes WPA Mixed Enterprise Access Point WDS AP mode Wireless Security 2 4G Security Mode Encryption WPA Mixed Enterprisel Both TKIP AES Group Key Update Interval 3600 Radius Server Radius Port Radius Secret 1812 Radius Accounting Disable y Radius Accounting Server Radius Accounting Port 1813 Radius Accounting Secret Interim Accounting Interval Fast Roaming Enable Enable Enable Fast Roaming Advanced Search Encryption Select the WPA encryption type you would like Please ensure that your wireless clients use the same settings Radius Server Enter the IP address of the Radius server Radius Port Enter the port number used for connections to the Radius server Radius Secret Enter the secret required to connect to the Radius server 44 Group Key Update Interval Specifies how often in seconds the Group Key changes Radius Accounting Enable or disable accounting feature Radius Accounting Server Enter the IP address of the Radius accounting server Radius Accounting Port Enter the port number used for connections to the Radius accounting server Radius Accounting Secret Enter the secret required to connect to the Radius accounting server Interim Accounting Interval Specifies how often in seconds the accounting data sends Note 802 11n does not allow WEP WPA PSK TKIP WPA2 PSK TKIP security mode The connection mode will
42. ter 2 Before You Begin 11 Computer Settings Windows XP Windows 7 Windows 8 In order to use the ENH710EXT you must first configure the TCP IPv4 connection of your Windows OS computer system 1b Move your mouse to the lower right hot corner to display the Charms Bar and select the Control Panel in Windows 8 OS 1a Click the Start button and open the Control Panel Settings m Administrator Internet Internet Explorer Sy E mail Microsoft Office Outlook Internet Explorer Tera Term Pro Command Prompt A Notepad Network val Wireshark Documents ES My Documents I ut 4 My Recent Documents _ Se My Pictures Command Prompt w Microsoft Office Word 2003 e My Music 43 My Computer gt Control Panel IxChariot Console e Paint Connect To Control Panel Devices and Printers Thursday October 11 Notepad S CCleaner Run ES WordPad e Connect To ur 7 Zip File Manager e EnGenius Wireless Utility Y Help and Support a Search 3 Mozilla Firefox 7 Run all Programs P Log Off Turn OFF Camputer Windows XP Set Program Access and DeFaults xC IxChariot Console ca ln Windows XP click Network Connections e Tera Teri Pra Va Printers and Faxes a Microsoft Office Excel 2003 All Programs D Network Connections Windows 7 ch In Windows 7 Windows 8 click View Network Status and Tasks in the Network and Inte
43. terface or 2 4 GHz 5 GHz WLAN interface Speed Test Parameters Target IP Domain Name Time Period 20 Sec Check Interval 5 Sec Start IPv4 Port 9001 IPv6 Port 5002 LED Control LED Control Power Enable LAN Enable WLAN 2 4GHz Enable WLAN 5GHz Enable y Apply Apply saved settings to take effect Power Enables or disables the Power LED indicator LAN Enables or disables the LAN LED indicator WLAN 2 4 GHz Enables or disables the WLAN 2 4 GHz LED 5 indicator WLAN 5 GHz Enables or disables the WLAN 5 GHz LED indicator Device Discovery This page allows you to discover devices from network for Operation Mode IP Address System MAC Address and Firmware version Device Discovery Device Name Operation Mode IP Address System MAC Address Firmware Versio Scan Account This page allows you to change the ENH710EXT username and password By default the username is admin and the password is admin The password can contain from O to 12 alphanumeric characters and is case sensitive Account Settings Account Settings Administrator Username Current Password New Password Verify Password Administrator Username Enter a new username for logging in to the New Name entry box Current Password Enter the old password for logging in to the Old Password entry box New Password Enter the new password for logging in to the New Passwor
44. ternal memory To view the logged information click the Log link under the System Manager menu If there is not enough internal memory to log all events older events are deleted from the log When powered down or rebooted the log will be cleared System Log Status Log type Refresh Clear Enable All y 8 26 01 ENH9OOEXT cron info cro 8 25 01 ENHSOOEXT u 8 25 01 ENHSOOEXT cron info cr 4 Grond USER root pid 3924 cmd 8S a root starting nt ond 2539 crond USER root pid 3909 cmd 8 24 01 ENH9OOEXT cron info crond 2539 crond USER root pi 90 8 22 01 ENHSOOEXT cron info crond 2539 crond USER root pi 89 8 20 01 ENHSOOEXT user notice root starting ntpd 8 20 01 ENHSOOEXT cron info crond 2539 crond USER root pi 8 8 20 01 ENHSOOEXT cron info crond 2539 crond USER roo i 8 8 18 01 ENHSOOEXT cron info crond 2539 crond USER roo i 8 16 01 ENHSOOEXT cron info crond 2539 crond USER root pi n nd 2539 25 0 25 Of 25 0 25 0 25 0 25 0 25 0 25 Of 25 0 25 0 Sep Sep Sep Sep Sep Sep Sep Sep Sep Sep 4 61 Remote Log This page allows you to setup the Remote Log functions for the ENH710EXT Disable 0 0 0 0 Remote Log Log Server IP Address Syslog Enables or disables the syslog function Log Server IP Address Enter the IP address of the log Server Remote Log Enable or disable the remote log service Apply Click Apply to apply
45. to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This transmitter must not be co located or operating in conjunction with any other antenna or transmitter IMPORTANT NOTE Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator amp your body 64 Appendix B CE Interference Statement Europe EU Declaration of Conformity This device complies with the essential requirements of the R amp TTE Directive 1999 5 EC The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R amp TTE Directive 1999 5 EC e EN60950 1 Safety of Information Technology Equipment e EN50385 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields 0 Hz 300 GHz e EN 300 328 Electromagnetic compatibility and Radio spectrum Matters ERM Wideband Transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using spread spectrum modulation t
46. twork Settings nnne 47 Chapter 8 Management sr 48 Management VLAN Settings nnne 49 Advanced Serna aa vara d cubi 50 CLI Settings Email Alerts 51 AO ZONG nante 53 Auto Reboot Settings eene 54 WiFi 55 TOO ado 56 ACCOUNUF TMW rasa 58 BACKUDIREOStO Sarai 59 ono 61 WO SOUT IRES Cl ida 62 ei OD teste et cet 63 FCC Interference Statement enne 64 CE Interference Statement enne 65 IC Interference Statement enne 68 Professional Installation Instruction css 69 Instructions d installation professionnelle 70 Detachable Antenna Ueage nee 1 Chapter 1 Product Overview Introduction Key Features Up to 27 dBm transmit power enabling long range connectivity Supports IEEE802 1 1a b g n wireless standards with up to 300 Mbps data rate on each band Two detachable 5 dBi 2 4 GHz Omni directional antennas Two detachable 7 dBi 5 GHz Omni directional antennas Can be used with included power adapter or via PoE with PoE 802 3at capable switches or injectors Band Steering shifts dual band clients to 5 GHz for better throughput performance Secured Guest Network option available Introduction The ENH710EXT is a high powered long range 2x2 Dual Band Wireless 802 11a b g n Outdoor Access Point with speeds up to 450 Mbps on both its high powered 2 4 GHz and 5 GHz radios It can be configured as an Access Point Client Bridge or WDS AP Station Bridge The ENH710OEXT is designed to operate in a v
47. ty 35 Spanning Tree Status Enables or disables the Spanning Tree function Hello Time Specifies Bridge Hello Time in seconds This value determines how often the device sends handshake packets to communicate information about the topology throughout the entire Bridged Local Area Network Max Age Specifies Bridge Max Age in seconds If another bridge in the spanning tree does not send a hello packet for a long period of time it is assumed to be inactive Forward Delay Specifies Bridge Forward Delay in seconds Forwarding delay time is the time spent in each of the Listening and Learning states before the Forwarding state is entered This delay is provided so that when a new bridge comes onto a busy network it analyzes data traffic before participating in the network Priority Specifies the Priority Number A smaller number has a greater priority than a larger number Save Click Save to confirm the changes Chapter 2 4 GHz amp 5 GHz Wireless Wireless Wireless Settings Wireless Settings Device Name ENH 10EXT Country Region United States Disable Band Steering NOTE In order for Band Steering function to work properly both 2 4GHz and 5GHz SSID and security settings must be the same Device Name Enter a name for the device The name you type appears in SNMP management This name is not the SSID and is not broadcast to other devices Band Steering Enable Band Steering to send 802 11n
48. uise est de 50 ohms Conform ment a la r glementation d Industrie Canada le pr sent metteur radio peutfonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pourl metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio lectriquea l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que lapuissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire al tablissement d une communication satisfaisante Le pr sent metteur radio IC 10103A ENH710EXT Model ENH710EXT a t approuv par Industrie Canada pour fonctionner avec les types d antenne num r s ci dessous et ayant un gain admissible maximal et l imp dance requise pour chaque type d antenne Les types d antenne non inclus dans cette liste ou dont le gain est sup rieur au gain maximal indiqu sont strictement interdits pour l exploitation de l metteur Approved Antenna s List Type Dipole Gain 5dBi for 2 4GHz 7dBi for 5GHz 71