1. 10 1 2 UPS UPS UPS PARLE gt SAAR FRAR 12 OH UPS UPS UPS UPS wipe
2. RARA A Smart App Online UPS renee n AC 120V 8 4A MAX 50 60Hz 1000VA 900W AC 120V 6 10 12 5A MAX 50 60Hz ii AC 120V 12 5A MAX 50 60Hz 1500VA 1350W AC 120V 6 10 18 4A MAX 50 60Hz AC 120V 18 4A MAX 50 60Hz 2200VA 1800W AC 120V 6 10 25 0A MAX 50 60Hz OL3000RTXL2U Aih AC 120V 25 0A MAX 50 60Hz 3000VA 2700W OL1500RTXL2U OL2200RTXL2U 1 UPS TH LH PHELAN Ri Br fa 2 3 a A B C D u E
3. 5 6 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate the UPS CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to power drain this equipment turn off and unplug the unit CAUTION The battery can power hazardous components inside the unit even when the AC input power is disconnected CAUTION The UPS should be placed near the connected equipment and easily accessible CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range
4. CAUTION No User Serviceable Parts Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Non Isolated Battery Supply Risk of electric shock battery circuit is not isolated from AC power source hazardous voltage may exist between battery terminals and ground Test before touching CAUTION To reduce the risk of fire connect the UPS to a branch circuit with 12 amperes OL1000 15 amperes OL1500 20 amperes OL2200 30 amperes OL3000 maximum over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION The AC outlet where the UPS is connected should be close to the unit and easily accessible CAUTION Please use only UL marked mains cable e g the mains cable of your equipment to connect the UPS to the AC outlet CAUTION Please use only UL marked power cables to connect any equipment to the UPS CAUTION When installing the equipment ensure that the sum of the leakage current of the UPS and the connected equipment does not exceed 3 5mA CAUTION The OL1000 OL1500 OL2200 OL3000 models may only be installed by qualified maintenance personnel CAUTION Do not unplug the unit from AC Power during operation as this will invalidate the protective ground insulation CAUTION To avoid electric shock turn off and unplug the unit before installing the input output power cord with a ground wire Con
5. berPower Reliability Quality Value Cy User s Manual OL1000RTXL2U OL1500RTXL2U OL2200RTXL2U OL3000RTXL2U CyberPower Systems Inc www cpsww com K01 0000232 01 i w T e 0 0 0 0 0 o o o o o o e es gt UPS yt o i ER Th R AT HF 40 Bl A conden BOR UPS UPS UPS De Th AR SY EO IA PRE Be EA gt E PATIRE UPS resem Hm RAE i UPS UPS
6. A a a WON Press the A and W buttons to scroll to the language that you want to select You may be prompted to save the selection if so press the ENTER button to save the setting 7 Press the ESC button to cancel or return to previous LCD menu LCD SETTINGS CONFIGURATION There are 21 UPS settings that can be configured by the user 1 Press the ENTER button to activate the MAIN MENU 2 Press the A and W buttons to scroll to the Configure option 3 Press the ENTER button to select the Configure submenu 4 Press the A and W buttons to scroll to the Configure submenu in the following table 5 Press the ENTER button to select the setting you want to configure The first configuration parameter will be displayed on the second column of LCD screen 6 Press the A and W buttons to scroll through the different parameters 7 Press the ENTER button to select the parameter you want to change You may be prompted to save the selection if so press the ENTER button to save the setting Some options are saved and started automatically See the following table for additional details 8 Press the ESC button to cancel or return to the previous LCD menu Copyright 2012 CyberPower Systems Inc LCD SETUP FUNCTIONS Configure Submenu Available Settings Default Setting Output Voltage 100V 110V 115V 120V
7. UPS has no bypass when Converter Mode is enabled This function can only be set before the UPS is on SILENCING AUDIBLE ALARMS 1 Press any of four function buttons on the LCD module Note the alarm can not be turned off for a Battery Low condition This condition will still result in an audible alarm 2 Change the Audible Alarms option to Disabled in the LCD screen and it will no long give an audible alarm for any malfunction MANUAL BATTERY TEST Select Active in the Battery Test portion of the LCD screen and the unit will perform a manual battery test Copyright 2012 CyberPower Systems Inc LCD MODULE REMOTE CONTROL and WALL MOUNTING INSTRUCTIONS REMOTE CONTROL WALL MOUNTING INSTRUCTIONS Step 1 Remove the Multifunction LCD Module Step 1 Remove the Multifunction LCD Module Unscrew the right panel of the UPS Separate the right panel from the Unscrew the right panel of the UPS Separate the right panel from the UPS Gently lift the LCD module out Reinstall the right panel UPS Gently lift the LCD module out Reinstall the right panel Step 2 Connect the DB26 Cable Step 2 Rotate the DB26 Connector of LCD Module Connect the DB26 cable from LCD module to the Remote Control Step 3 Connect the DB26 Cable Port on the front panel as shown in the following figure Connect the DB26 cable from LCD module to the Remote Control Port on the front panel as shown in the following figure Step 4 Mount LCD M
8. Voltage Range Input Frequency Range Inout Power Factor Cold Start lt es Output Waveform Sine wave Output Voltage 120Vac 2 Output Frequenc 50 60Hz Auto Sensing or Configurable 0 25Hz Transfer Time Typically Oms Rated Power Factor oB 09 Harmonic Distortion THD lt 3 at Linear Load lt 5 at Non linear Load Crest Factor 3 1 ECO Mode Voltage Regulation 10 15 Configurable i 6 NEMA 5 20R 6 NEMA 5 20R UPS Outlets 8 NEMA 5 15R 1 L5 20R 1 L5 30R Protection Surge Protection lIEc et000 45Level3 Phone Network Protection RJ11 RJ45 One In One Out Overload Protection Line Mode 105 125 Load for 1 min 126 150 Load for 10 sec Battery Mode 105 130 Load for 10 sec 131 150 Load for 2 sec Short Circuit Protection UPS Output Cut off Immediately or Input Fuse Circuit Breaker Protection Battery Specifications GyveAH lveAhH Recharge Time Typically 44nous Sealed Maintenance Free eS Hot Swappable fe Status Indicators Multi Function LCD Readout that Supports Multi Language Interface 19 Types of Read Out 21 Types of Function Setting 3 Event Logs LED Indicators Power On White Line Mode Green Battery Mode Yellow Bypass Mode Yellow Fault Red Replace Battery Red Audible Alarms 6 Audible Alarms Environment Operating Temperature 32Fto104F 0Cto40C Operating Relative Humidity 0 t
9. button to turn on UPS Over Charge Charger Failure High O P V Low O P V Bus Fault Battery is overcharged Charger has failed Output voltage is too high Output voltage is too low Internal DC bus voltage is too high or too low 1 Remove battery connector and check charger voltage 2 Contact CyberPower for repair 1 Shut down UPS and turn off input breaker 2 Contact CyberPower for repair CyberPower Systems Inc www cpsww com Entire contents copyright 2012 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel Business Edition and PowerPanel Personal Edition are trademarks of CyberPower Systems Inc Copyright 2012 CyberPower Systems Inc
10. tools with insulated handles Do not lay tools or metal parts on top of the UPS or battery terminals Replacement Batteries Please refer to the front side of the UPS for the model number of the correct replacement batteries For battery procurement log onto www CPSww com or contact your local dealer Battery Disposal Batteries are considered hazardous waste and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries Do not dispose of batteries in fire Step 1 Remove the front panels the cover itself Step 2 Remove the retaining screws from the cable protection cover and then remove Step 3 Unscrew the connectors fixed plates on the battery retaining cover Step 4 Pull the battery tray out slowly and then put the new battery tray back into the compartment Copyright 2012 CyberPower Systems Inc Step 5 Fasten back the connectors on the battery retaining cover Then insert the battery connectors and tighten the screws of battery retaining cover Step 6 Install the front panels TECHNICAL SPECIFICATIONS Modell OL1000RTXL2U OL1500RTXL2U OL2200RTXL2U OL3000RTXL2U Configuration Capacity vA 1000VA 1500VA 2200VA 3000VA Capacity Watts 900w 1350W 18ow 2z7roow __ FormFactor J Rackmount Tower Energy saving Technology Ces ECO Mode Efficiency gt 93 o 120Vac 50 60Hz Input
11. 127V 120V Range 1 2 3 4 5 Sync Freq Window 5 6 7 8 9 10 Range 10 10 10 15 10 20 Bypass V Window 10 15 1 5 1 0 1 5 1 5 1 5 20 Bypass Condition Check Freq Volt Check Volt Only No Bypass Check Freg Volt Disable Enable Disable ECO Mode V Range 15 V Range 10 V Range 10 Manual Bypass Disable Enable Disable Battery Test Activate None Audible Alarms Disable Enable Enable EBM Number 0 1 2 3 4 5 6 7 8 9 10 0 Wiring Fault Disable Enable Disable NCL Control Outlet On Outlet Off Outlet On Language English Espafiol Spanish Frangais French Deutsch German English Generator Mode Disable Enable Disable Communication Disable Enable Enable I P Power Fail Battery Low Summary Alarm Dry Relay Set I P Power Fail UPS On Bypass UPS Fail Converter Mode Converter Off O P Freq 50Hz O P Freq 60Hz Converter OFF Screen Saver Disable 1 Minutes 5 Minutes 5 minutes Clear Event Log Activate None Button OFF LOCK Disable Enable Disable Charger Function SBM Constant SBM Signal Inputs Disable EPO ROO Disable 100V are derated by 20 110 V are derated by 10 This function can t be set when Manual Bypass Generator Mode or Converter Mode is enabled UPS has no bypass when Generator Mode is enabled
12. NSTALLATION ELECTRICAL INSTALLATION After completing the hardware installation of the UPS you are now ready to plug in the UPS and connect your equipment SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conductive contaminants Do not install this UPS where excessive moisture or heat is present Please see specifications for acceptable temperature and humidity range CAUTION Never install a UPS or associated wiring or equipment during a lightning storm CAUTION Do not work alone under hazardous conditions CAUTION In case of the risk of electric shock do not remove the top cover CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected Copyright 2012 CyberPower Systems Inc INSTALLING YOUR UPS SYSTEM SYSTEM BLOCK DIAGRAM Input Line Mode ps Battery Mode z Bypass Mode HARDWARE INSTALLATION GUIDE 1 Battery charge loss may occur during shipping and storage Before using the UPS it s strongly recommended to charge batteries for four hours to ensure the batteries maximum charge capacity To recharge the batteries simply plug the UPS into an AC outlet 2 When using the included software connect either the serial or the USB cable between the computer and the corresponding port on the UPS Note If the USB port is used the serial port will be disabled They cann
13. can be configured by the user Event Log Displays the 3 most recent events by event count time day hour minute and event description LCD INFORMATION READOUT There are 19 types of UPS information available for display 1 Press the ENTER button to activate the MAIN MENU Press the A and W buttons to scroll to the Information option Press the ENTER button to select the Information submenu Press the A and W buttons to scroll through the Information submenu in the following table ot pi N Press the ESC button to return to UPS Status Information Submenu Description O P Volt XXX XV Displays the Output Voltage O P Freq XX XHz Displays the Output Frequency I P Volt XXX XV Displays the Input Voltage I P Freq XX XHz Displays the Input Frequency O P Load O P Amp O P Watt XXXXXW Displays the Output Wattage O P VA XXXXXVA Displays the Output VA BAT Volt XXX XV Displays the Battery Voltage XXX Displays the Output Load as a Percentage of Maximum load X XA Displays the Output Current BAT Cap XXX Displays the Estimated Percentage of Battery Capacity BAT Runtime XXXM Displays the Estimated Battery Runtime in Minutes EBM Number X Displays the External Battery Module Number Displays the Approximate inside Temperature in both C Celsius and F Fahrenheit for the UPS TEMP XX C XXX SBM XXXXX Displays the Stage of Smart Battery Managem
14. ent Rating XXK VA Displays the UPS Rating MCU Ver XXXX Displays the MCU Firmware Version Model Name Displays the UPS Model Name 298 a i Displays the present Date amp Time Next BAT Change XXX XXXX Displays the next Battery Change Date amp Time Copyright 2012 CyberPower Systems Inc LCD SETUP FUNCTIONS LCD EVENT LOG 3 Event Logs of UPS can be recorded 1 Press the ENTER button to activate the MAIN MENU 2 Press the and W buttons to scroll to the Event Log option 3 Press the ENTER button to select the Event Log submenu 4 Press the A and W buttons to scroll through the Event Log submenu in the following table 5 Press the ESC button to return to UPS Status Event Log Submenu Description XXDXXHXXM without PowerPanel Business or RMCARD302 X 1 with PowerPanel Business or RMCARD302 Event Content MULTI LANGUAGE INTERFACE Users can configure 1 of the 4 available languages for display English Espanol Spanish Francais French Deutsch German h Press the ENTER button to activate the MAIN MENU Press the A and W buttons to scroll to the Configure option Press the ENTER button to select the Configure submenu Press the A and W buttons to scroll through the Language options Press the ENTER button to select the Language submenu
15. ese installations give operators a single access point to immediately power off all equipment connected to the UPS during an emergency 11 To avoid electric shock turn the unit OFF and disconnect the unit from utility power before hardwiring the UPS in out power cord The in out power cord MUST be grounded Copyright 2012 CyberPower Systems Inc BASIC OPERATION POWER MODULE FRONT REAR PANEL DESCRIPTION 1 Power Button Power on Indicator Master ON OFF for the UPS Indicates that the UPS is on and supplying power 2 UPS Status Fault Replace Battery LED Indicator Indicates the status of the UPS displaying whether it is operating in Line Battery or Bypass Mode if it has an internal fault or if the battery needs to be replaced 3 Multifunction LCD Readout Shows UPS status information settings and events 4 Function Buttons Scroll up scroll down select and cancel LCD menu 5 Input Circuit Breaker Provides input overload and fault protection 6 Battery Backup amp Surge Protected Outlets Provides battery backup and surge protection They ensure power is provided to connected equipment over a period of time during a power failure Critical Noncritical Load Allows the creation of load priorities to ensure that battery 43 power reserves are transferred to specified outlets during a power outage The unit can be programmed to provide additional runtime for equ
16. f f i i BATTERY ww ce cre REPLACE ON LINE BATTERY Bypass FAULT REPLACE LED INDICATORS UPS STATUS LED Indicators Color UPS Status Description ON OFF White UPS power is on ON LINE Green UPS is operating in Line Mode BATTERY ON Yellow UPS is operating in Battery Mode BYPASS Yellow UPS is operating in Bypass Mode Manual Bypass or ECO Economy Mode FAULT Red UPS has an internal fault See Trouble Shooting for additional information REPLACE BATTERY Red Battery will soon need to be replaced due to insufficient runtime LCD SCREEN UPS STATUS LCD Screen UPS Status Description Line Mode UPS is operating in Line Mode Battery Mode UPS is operating in Battery Mode Bypass Mode UPS is operating in Bypass Mode Manual Bypass UPS is operating in Manual Bypass ECO Mode UPS is operating in ECO Economy Mode BUTTON OPERATION Button Operation Description ON OFF Press this button to turn on or turn off UPS A Press this button to scroll up in the LCD menu d Press this button to scroll down in the LCD menu ENTER Press this button to select an option ESC Press this button to cancel or return to previous LCD menu Copyright 2012 CyberPower Systems Inc LCD SETUP FUNCTIONS MULTI FUNCTION LCD MAIN MENU Press Enter button to activate MAIN MENU MAIN MENU submenu Function Description Information Displays the UPS information Configure Displays the UPS settings that
17. fer to the technical specifications Output S AC LCD Module DC Dope Control c lt gt USB amp DBO ca X Monitoring i SNMP Siot 6 This UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically charge even when the unit is switched off 7 To maintain an optimal battery charge leave the UPS plugged into an AC outlet at all times 8 Before storing the UPS for an extended period of time turn the unit OFF Then cover it and store it with the batteries fully charged Recharge the batteries every three months to ensure good battery capacity and long battery life Maintaining a good battery charge will help prevent possible damage to the unit from battery leakage 9 The UPS has one USB port default and one Serial port that allows connection and communication between the UPS and any attached computer running the PowerPanel Business Edition Agent software The UPS can control the computer s shutdown during a power outage through the connection while the computer can monitor the UPS and alter various programmable parameters Note Only one communication port can be used at a time The port not in use will automatically become disabled or the serial port will be disabled if both ports are attached 10 EPO Emergency Power Off Port EPO ports allow administrators the capability to connect the UPS unit to customer supplied EPO switches Th
18. he instructions below for the respective mounting methods SAFETY PRECAUTIONS CAUTION To prevent the risk of fire or electric shock only use the supplied hardware to attach the mounting brackets RACKMOUNT INSTALLATION Step 1 Rackmount ears installation Attach the two rackmount ears to the UPS using the provided screws M5X8L 8pcs Step 2 Rackmount rail Installation The rails adjust to mount in 48 cm 19 inch panel racks from 52 to 91 5cm 20 5 to 36 inches deep Select the proper holes in the rack for positioning the UPS in the rack The UPS takes up position 1 through position 6 position 3 position 8 position 6 position 5 position 2 position Step 3 Adjust rackmount rails to fit your rack Attach the rackmount rail to your rack with two M5X12L screws and two plastic washers at the front of the rack Located in position 1 amp position 6 Do not tighten the screws Adjust the rail size on the rail assembly of your rack Secure the rail to the rear of the rack with two M5X12L screws and two plastic washers Tighten all screws at the front and rear of the rail Once completed perform the same steps for assembling the other rackmount rail Place the UPS on a flat stable surface with the front of the unit facing toward you Secure the UPS to your rack with four M5X12L screws at the front of the rack Located in position 2 amp position 5 Copyright 2012 CyberPower Systems Inc HARDWARE I
19. ipment connected to the 8 40 D 9 6 CRITICAL outlets while stopping the power supply to equipment connected to NONCRITICAL outlets after a designated period of time 7 Serial Port Serial port provides communication between the UPS and the computer The UPS can control the computer s shutdown during a power outage through the connection while the computer can monitor the UPS and alter its D 43 44 various programmable parameters 8 USB port _ _ _ _ 1 A 44 N KR fi This is a connectivity port which allows communication 40 UY X and control between the UPS and the connected computer It is recommended to install the PowerPanel Business Edition Agent software on the PC Server connected with the USB cord 9 Surge Protected Communication Ports RJ 45 RJ 11 These ports are used to protect standard RJ 45 RJ 11 based products ADSL LAN Phone Modem Lines and cabling systems from surges 10 Relay Output Connector Convert UPS signals into real potential free Dry Contacts 13 EPO Emergency Power Off Connector for industrial control Enables an emergency UPS Power Off from a remote location 11 SNMP HTTP Network slot 14 AC Input Inlet Slot to install the optional SNMP card for remote network Connect the AC Power cord to a properly wired and grounded outlet control and monitoring Copyright 2012 CyberPower Systems Inc OPERATION INSTRUCTIONS FOR LCD MODULE f 1
20. nect the ground wire prior to connecting the line wires CAUTION Do not use an improper size power cord as it may cause damage to your equipment and cause fire hazards CAUTION Wiring must be done by qualified personnel CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT Under no circumstances this unit should be used for medical applications involving life support equipment and or patient care CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out CAUTION Do not dispose of batteries in fire as the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles CAUTION The unit has a dangerous amount of voltage When the UPS indicators is on the units may continue to supply power thus the unit s outlets may have a dangerous amount of voltage even when it s not plugged in to the wall outlet CAUTION Make sure everything is turned off and disconnected completely before conducting any maintenance repairs or shipment CAUTION Connect the Protecti
21. o 90 Non Condensing Management On Device Features Self Test Auto Charge Auto Restart Auto Overload Recovery Connectivity Ports 1 Serial Port RS232 1 USB Port 1 Relay Out SNMP HTTP Capable 1 Expansion Port With optional SNMP card Ho Power Management Software PowerPanel Business Edition Physical LxWxH 16 9 x 17 x 3 5in Lx W xH 23 6 x 17 x 3 5in Dimensions 43 x 43 3 x 8 8cm 60 x 43 3 x 8 8cm Net Weight 39 6lbs 18Kg 68 2lbs 31Kg Safety D Conformance Approvals CE UL 100V are derated by 20 110 V 115V are derated by 10 Battery Mode Battery Low Overload UPS Fault Replace Battery Copyright 2012 CyberPower Systems Inc TROUBLE SHOOTING Problem Possible Cause Solution Warning O P Overload Load Over XXX Battery Mode Battery Low BAT Disconnected Battery Failure Replace Battery EPO OFF Wiring Fault Line Abnormal Output Short Over Temperature Coldstart Lock Autorestart Lock Your equipment requires more power than the UPS can provide If the UPS is in Line Mode then it will transfer to Bypass Mode if the UPS is in Battery Mode it will shutdown Your equipment requires more power than the setting in the Power Management Software PowerPanel Business will allow UPS is operating on battery power UPS is operating on battery power and will be shutting down soon due to extremely low battery voltage Mi
22. odule on the Wall Wall mounting hole D 10 D 5 13 8L SAFETY PRECAUTIONS CAUTION It must be done by qualified personnel CAUTION To avoid electric shock turn off and unplug the unit before installing REMOTE CONTROL or WALL MOUNTING INSTRUCTIONS Copyright 2012 CyberPower Systems Inc MAINTENANCE Storage To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery life Battery Replacement Please read and follow the Safety Instructions before servicing the battery Battery replacement should be performed by trained personnel who are familiar with the procedures and safety precautions Make a note of the replacement Battery tray number Safety Precautions CAUTION Only use replacement batteries which are certified by CyberPower Systems Use of incorrect battery type is an electrical hazard that could lead to explosion fire electric shock or short circuit CAUTION Batteries contain an electrical charge that can cause severe burns Before servicing batteries please remove any conductive materials such as jewelry chains wrist watches and rings Battery Installation CAUTION Do not open or mutilate the batteries Electrolyte fluid is harmful to the skin eyes and may be toxic CAUTION To avoid electric shock turn off and unplug the UPS from the wall receptacle before servicing the battery CAUTION Only use
23. on Earth PE safety conductor before any other cables are connected WARNING Fuses To reduce the risk of fire replace only with the same type and rating of fuse DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS OUTPUT SOCKETS SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY PERSONNEL KNOWLEDGE OF BATTERIES AND THE REQUIRED PRECAUTIONS KEEP UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES Copyright 2012 CyberPower Systems Inc UNPACKING SS Phone line Serial Interface Cable RS 232 yY Flat head screws M5X8L 8 Si rs N 7 Rigiste Cara Pan head screws M5X12L 12 O Plastic washers 8 Rackmount left rail Rackmount right rail D Optional I Screw hole dust covers 10 User s manual Register card CE 6 6 j 6 j Rackmount ears Stands 2 PowerPanel Business Edition software CD Copyright 2012 CyberPower Systems Inc HARDWARE INSTALLATION HARDWARE INSTALLATION These versatile UPS systems can be mounted in a rackmount or vertical tower orientation This versatility is especially important to growing organizations with changing needs that value having the option to position a UPS on a floor or in a rackmount system Please follow t
24. ot be used simultaneously After connecting to either the USB port or the Serial port on the UPS a computer with the PowerPanel Business Edition Agent software installed can control the operating schedule battery test outlets as well as obtain UPS status information However other computers with PowerPanel Business Edition Client software can only obtain UPS status information via LAN connection 3 Connect your computer monitor and any externally powered data Storage device Hard drive Tape drive etc into the outlets only when the UPS is off and unplugged DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax machine telephone modem line or network cable connect the telephone or network cable from the wall jack outlet to the jack marked IN on the UPS and connect a telephone cable or network cable from the jack marked OUT on the UPS to the modem computer telephone fax machine or network device 5 Press the ON OFF switch to turn the UPS on The Power On indicator light will display when activated If an overload is detected an audible alarm will sound and the UPS will continuously emit two beeps per second For resetting the unit unplug some equipment from the outlets Make sure your equipment carries a load current within the unit s safe range re
25. ssing battery power UPS has failed a Battery Test Battery will soon need to be replaced due to insufficient runtime Missing the EPO connection Line and neutral wires are reversed Missing ground wire No ground wire Wrong utility power backed up during UPS auto restart Output short circuit High ambient temperature UPS is locked to prevent consuming battery power during shipping Automatic Restore is disabled in Power Management Software PowerPanel Business Shut off non essential equipment If this solves the overload problem the UPS will transfer to normal operation Shut off the non essential equipment or increase the level in the Power Management Software Save your data and perform a controlled shutdown UPS will restart automatically when acceptable utility power returns Check battery connector and battery breaker 1 Checkbattery connector and battery breaker 2 Contact technical support to replace the battery Contact technical support to replace the battery Check the EPO connection Exchange line and neutral wires Connect ground wire Disable Wiring Fault alarm on LCD panel Check whether voltage or frequency of utility power is out of range Your attached equipment may have problems please remove them and check again Check the fan for operation and if the ventilation hole has been covered Plug into utility power for first time operation Press ON OFF