1. This should not be displayed during normal business hours SKOPE B600 2 B600G 2 Temperature The chiller temperature setpoint is factory set at 1 C If necessary the Setpoint standard setting can be adjusted between 0 C and 4 0 C SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time To adjust the setpoint 1 Push and hold the set button PAS Set Up appears on the display Release the set button Push the set button four times Push the up button once Push the down button twice Push the defrost button twice Push the down button to nagivate to the parameter menu PS will show on the display 8 Push the set button to enter the parameter menu ZEE IESU N 9 Push and hold the set button to scroll through the parameter menu 10 Release the set button when SPC appears on the display 11 Push the up and down button to change the value 12 Once the desired mode setting is flashing on the display leave the controller for 20 30 seconds to save the setting Perishable The chiller has the ability to operate in either perishable mode or non Mode perishable mode When in perishable mode the symbol on the EMS controller faceplate is lit red when in non perishable mode the symbol is not lit Perishable mode is for use with perishable products such as dairy or food products When in perishable mode the chiller temperature is k
2. Cabinet Periodically wipe the inside and outside of the cabinet with a damp cloth taking care to keep moisture away from electrical parts As with any maintenance ensure the cabinet is isolated from the power supply before cleaning Condenser To ensure trouble free performance we strongly urge monthly cleaning with Coil a soft brush to remove dust and fluff A more thorough cleaning is recommended every six months by qualified service personnel The condenser coil must be kept clean for efficient and reliable operation WARNING Isolate the cabinet from the power supply before cleaning the condenser coil To clean the condenser coil 1 Remove the front panel and isolate the chiller from the mains power supply see above 2 Clean the condenser coil with a soft brush 3 Reconnect the chiller to the power supply and refit the front panel Servicing User Manual 12 SKOPE B600 2 B600G 2 Lighting This chiller is designed for use with LED tubes and is not compatible with fluorescent tubes IMPORTANT DO NOT use fluorescent tubes Interior Light The cabinet interior is lit by one 19 Watt T8 LED tube 226mm x 1200mm which can be replaced without moving shelves or removing product To replace the cabinet interior light 1 Remove the front panel and isolate the chiller from the mains power supply see previous page 2 Remove the diffuser by squeezing it until it is released from the aluminium housing and
3. 0 00000 ccc RR RR 5 VENUIAUON saara ban ed wee ee hee eee og 5 aos wad ee 5 Before Operating 0 0c ce eee 5 Fower COT M r 5 ed IRE TETTE EIE TRITT TIT OD 6 Bottom Shelf lille RII 6 Wire Shelves 4 53 uad aded aed Y o x Codd wed dedo RR CR ae aa 6 2 Operation Automatic Start Up aa aaa 7 Loading Prod C 6 i4 ichawn cho ee he wes Ghee ted nw soba teen mows T EMS Controller Operations a na anaa aana ee eee 8 IDIFOdUCHOD sarr exar eert wx SENEE TENORAR NENEA 88 8 Self Learning 0 0 0 cee eee eee 8 Motion Sensor amp Door Switch 0 0 0 0 cee eee 8 Faceplate aa gure a Gen we Reo Hee eal owas ban eee oes 9 Temperature Setpoint 0 0 0 0 ce ee 10 Perishable Mode 0 00 ccc eee 10 Messages and Alarms 0 0 00 cee ee eee 11 3 Servicing Isolating Electrics llli 12 erc MEMT 12 Cabinet 12 Condenser Coll s s ace exem ALSO EORR EG Ed Ear AR GS wes 12 LONN NETTE RO T ITTETOTOITT OIL 13 Interior Light 0 2 0 ccc I 13 vli RM PRC L 14 Troubleshooting 2 0 0 0 eee eee 15 SKOPE B600 2 B600G 2 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference When the appliance is used by or near yo
4. then push the diffuser out of the way 3 Rotate the LED tube until LED Tube Pins Lamp Holder the pins on the ends ofthe partially removed tube align with the slots then slide it out 4 Fita new LED tube Note the pointer at each end of the tube should be set to the 0 position 5 Refit the diffuser by slipping the back section into the housing then squeezing and snapping the front section of the diffuser into place as you work down the length of the light Servicing 13 User Manual SKOPE B600 2 B600G 2 14 Sign Light B600G 2 only The sign unit is lit by one 11 Watt T8 LED tube 226mm x 600mm which can be replaced by removing the front sign panel To replace the sign light 1 Remove the front panel and isolate the chiller from the mains power supply see page 12 Remove the sign assembly Lift the assembly up and off the sign sides and unplug it from the cabinet Screw driver Remove the sign top cover by undoing the fixing screws from the top of the sign assembly Sign Assembly Slide the clear front panel and artwork if present up and out of the sign assembly Screw driver Undo the two inner lampholder fixing screws from the rear of the sign assembly Outer screw loosen Inner screw remove Loosen the two outside screws vertical slot screws and slide the lampholder brackets and LED tube to the bottom of the vertical slots Vertical s
5. User Manual MAN10530 Rev 2 5 Dec 2015 B600 2 B600G 2 oKOPE Single Door Vertical Chiller B600 2 no sign G60EV X5990 B600G 2 lit sign G60EV B600G 2 Ses EE ELD Refrigeration e SKOPE Warranty Protection Register now for peace of mind It s quick and simple Take a few minutes to register your SKOPE product and enjoy more efficient support plus other warranty benefits When registering make sure you have your cabinet serial number at hand To register online Visit our website at www skope com warrantyprotection then complete and submit the online registration form Or freephone 1800 121 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service amp Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative maintenance guidelines Helpful information is available on our website www skope com serviceandsupport Thank you for purchasing a SKOPE refrigeration product SKOPE B600 2 B600G 2 User Manual CONTENTS 1 Installation Safety FINS sms mem emnes dense Gudea nee are 4 Positioning the Cabinet lille 5 Chiller Location 0
6. able mode Perishable mode 12 Once the desired mode setting is flashing on the display leave the controller for 20 30 seconds to save the setting Messages and The following table explains messages that the EMS Advanced controller Alarms displays and related alarms Alarms signal unexpected operational changes in the chiller and stop when you disconnect the chiller from the power supply at the isolating switch Display Description When the chiller is in stand by mode the EMS Advanced controller displays three bars This should not be displayed during normal business hours When the chiller becomes operational the display changes to the temperature Defrost cycle in progress Door Open The EMS Advanced controller detects an open door through a door switch in the door and has found one open If it stays open over two minutes an alarm sounds but stops when the door closes again If the door remains open five minutes such as when loading product then the alarm stops and the EMS Advanced controller turns off the compressor The compressor starts again when the door closes High Temperature The refrigeration system has overheated and an alarm sounds The EMS Advanced controller turns off the system to avoid damage Contact a service agent Probe Failure A temperature sensor in the cabinet or condenser has failed and an alarm sounds Contact a service agent Refrigeration System Failure There is a refrigeration system failur
7. cing User Manual Possible Cause Suggestions e Check mains power supply Check isolating switch see page 12 Replace LED tube see page 13 e Movement in front of the motion sensor will reactivate it Contact an authorised service agent to replace it Clean the condenser coil see page 12 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 Ensure the cabinet is in a cool spot Ensure doors are closed more often Ensure product is not blocking airflow slots Ensure there is space around individual product pieces e Movement in front of the motion sensor will reactivate it e Change the controller to perishable mode see page 10 Clean the condenser coil see page 12 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 15 SKOPE Contacts SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to th
8. e and the EMS Advanced controller turns it off to avoid damage An alarm sounds when the system does not reach the preset temperature within 72 hours Contact a service agent Supply High The voltage from the main supply is too high and an alarm sounds The controller turns off the electrical motors continuously monitors the voltage level and restores power as soon as the voltage returns to a safe level Freeze up protection The cabinet temperature is too low The compressor stops running and the evaporator fans run continuously until the cabinet temperature reaches an acceptable level Supply Low The voltage from the main supply is too low and an alarm sounds The controller turns off the electrical motors continuously monitors the voltage level and restores power as soon as the voltage returns to an appropriate level Operation 11 User Manual SKOPE B600 2 B600G 2 3 Servicing Isolating Electrics You should isolate the cabinet from the power supply before attempting any maintenance Use the isolating switch to turn off electrics to the cabinet and refrigeration unit without unplugging the cabinet from the wall The isolating switch is located on the right hand side of the refrigeration unit compartment To isolate the power supply 1 Fully open the cabinet door and unscrew the front panel 2 Remove the front panel from the cabinet 3 Turn off the power to the cabinet 0 at the isolating switch Cleaning
9. e product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer Future owners of the product B600 2 B600G 2 SKOPE Single Door Vertical Chiller Type G60EV X5990 G6O0EV User Manual MAN10530 Rev 2 5 Dec 2015 2012 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SKOPE is a registered trademark of SKOPE Industries Limited
10. efrigeration unit compartment with the faceplate visible behind the front panel The EMS controller detects variable business hours and switches the chiller to active mode approximately two hours prior to opening and then changes to stand by mode at close of business While in the economical stand by mode the temperature inside the chiller is moderated and the cabinet lights turn off CAUTION The EMS controller must only be adjusted by an authorised service agent After initial start up the EMS controller goes into learning mode for 24 hours to establish the density of shopper traffic and the business s opening closing pattern It s always gathering data about shopping activity and updating itself A service agent is not required if the store hours change or you disconnect the power to move the chiller The EMS controller continuously collects data from two sources n motion sensor o door switch IMPORTANT Disconnecting the refrigeration unit from the power supply does not reset the self learning module Only an authorised service agent can adjust the program The motion sensor detects activity in front of the chiller and feeds data to the EMS controller The motion sensor is located on the faceplate of the EMS controller visible on the front panel The chiller is fitted with a door switch below the door The door switch tells the EMS controller how often the door is opened A small magnet in the door frame activates t
11. ept constantly cool at all times During standby periods the lights switch off and the fans cycle on and off Perishable mode must be used when perishable product is being stored inside the chiller IMPORTANT Ensure perishable mode is used when perishable product is being stored inside the chiller Non perishable mode is for use with non perishable products such as carbonated drinks and water When in non perishable mode the chiller temperature is moderated the lights switch off and the fans cycle on and off during standby periods resulting in maximum energy savings Follow the steps below to change between perishable and non perishable mode To change between perishable and non perishable mode 1 Push and hold the set button PAS Set Up appears on the display 2 Release the set button 3 Push the set button four times 4 Push the up button once Heelstat 5 Push the down button twice 6 Push the defrost button twice udo BOW Continued over page 10 Operation User Manual SKOPE B600 2 B600G 2 7 Push the down button to nagivate to the parameter menu PS will show on the display 8 Push the set button to enter the parameter menu 9 Push and hold the set button to scroll through the parameter menu 10 Release the set button when PEr appears on the display 11 Push the down button to change between perishable and non perishable mode 0 Non perishable mode 1 Perishable mode Non perish
12. er supply and current draw Installation User Manual SKOPE B600 2 B600G 2 Positioning the Cabinet Chiller The location of the chiller may be the single most important decision that will Location extend its life and ensure economical high performance We recommend that you put the chiller in the coolest place possible because it will use less power and last longer Allow adequate space for doors to open and close properly Self closing doors have internal torsion bars pretensioned at the factory and must be unobstructed Ensure the cabinet sits on a level surface so that the doors shut and correctly seal Level footing also prevents the condensate tray from overflowing Ventilation Ensure there is always at least a 50mm gap around the back top and underside of the cabinet Keep the ventilation slots in the front panel clear at all times never store cardboard cartons or other objects in front of the chiller CAUTION To prevent over heating and conserve energy ensure air flows freely all around the chiller including front back top and underside minimum 50mm gap Before Ensure both rear spacers are rotated outwards and fully tightened This will Back of Chiller Power Cord Power Cord The chiller has a flexible power cord fitted with a 3 pin plug which exits the rear of the cabinet at floor level Pull the power cord around so that it s not trapped before you position the cabinet Installation 5 User Ma
13. he switch Door Switch i Front Panel EMS Controller Motion Sensor Operation User Manual SKOPE B600 2 B600G 2 Faceplate Because the EMS controller plays such an important role it s helpful to know No Item B OO cls 000 10 Operation User Manual the parts of the faceplate you will use X elstat Description DEFROST button Manually activates an additional defrost cycle and used to program the controller The first automatic defrost occurs six hours after the first off cycle SET button Used to program the controller Eye of the infrared motion sensor It detects activity within five metres around the front of the chiller and feeds the data to the EMS controller LED for the compressor light green when on LED for the evaporator fan green when on LED indicating perishable mode red when on See page 10 for more information LED linked to the motion sensor and flashes red when there is activity around the chiller but otherwise off UP button Used to program the controller DOWN button Used to program the controller Digital display of cabinet temperature or messages see next page for details The temperature is what the sensor inside the chiller detects and not necessarily the product temperature However they may be very close depending on how the controller is set to sense temperature When the chiller is in stand by mode the controller displays three bars
14. lot Rotate and remove the Lamp holder Lamp holder bracket failed LED tube Fit the new LED tube Slide the lampholder brackets and LED tube to the top of the vertical slots and tighten the outside screws vertical slots screws Screw the two inner screws back into the assembly to fix the lampholder brackets and LED tube in place Refit the clear front panel and artwork if present and screw the sign top cover back onto the top of the sign assembly Plug the sign assembly back into the cabinet and slot the assembly back onto the sign sides Servicing User Manual Troubleshooting SKOPE B600 2 B600G 2 For questions about the EMS controller see Messages and Alarms on page 11 For problems with the cabinet and refrigeration cassette use the following table Problem Loss of power supply Isolating switch turned off Failed LED tube Cabinet not operating No controller display e Interior light not on Controller is in stand by mode e Blown cabinet fuse Power consumption Unit operating too is higher than hot expected Cabinet doors are opened excessively Restricted airflow to cabinet e Product is too warm Controller is in stand by mode e Controller is in non perishable mode e Warm cabinet Blocked condenser temperatures Compressor operating for long periods more than 1 hour Poor ventilation around refrigeration unit Servi
15. nual SKOPE B600 2 B600G 2 Bottom Shelf Wire Shelves Shelves The chiller is supplied with four wire shelves and one solid bottom stainless steel shelf The solid bottom shelf is fixed into place on the floor of the chiller It is important that this shelf is always in place as it directs the interior air circulation IMPORTANT For correct chiller operation the solid bottom shelf must always be in the bottom of the chiller The wire shelves may be fitted at different heights to suit various products Each shelf is held in place with four shelf clips which engage in the shelf support strips The support strips are numbered for easy location of shelf clips To fit the wire shelves 1 Unpack the shelves and shelf clips from inside the cabinet 2 Establish the desired position for the shelves and securely engage a shelf clip in each of the shelf support strips 3 Sit the shelves onto the shelf support strips Installation User Manual 2 Operation SKOPE B600 2 B600G 2 Operation User Manual Automatic Start Up After the cabinet has been positioned in a suitable place plug it in and check the following activity Item Condenser Fan Lighting Electronic Controller Compressor Evaporator Fan Activity The condenser fan starts when the chiller is plugged in The lights that illuminate the cabinet interior and top sign top sign fitted to BG600G 2 only will come on when the chiller is t
16. ung children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration cassette Do not probe any opening Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Only use this appliance with the voltage specified on the cabinet rating label affixed to the refrigeration cassette Ensure the chiller has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensure all necessary safety precautions are observed during installation or removal of the refrigeration cassette This appliance is not designed to be stable while in motion Use extreme caution when moving or transporting the appliance WARNING Always isolate the chiller from the mains power supply before attempting any maintenance CAUTION Never overload the power supply which could damage the chiller and product See the rating label inside the cabinet for the safe pow
17. urned on An electronic controller runs the chiller and is visible behind the front panel The display panel first flashes start up messages before stabilising on the cabinet temperature The compressor starts about three minutes after the lights go on To verify listen for the compressor and check that the COMPRESSOR light is green on the EMS Advanced controller The compressor turns off when the product temperature reaches around 2 C and turns on again when it reaches about 4 C The evaporator fan starts about 30 seconds after the compressor To verify check that the FAN light is green on the EMS controller After initial start up the EMS electronic controller starts its self learning process and the cabinet will operate without any assistance Refer to Self Learning on page 8 for more information Loading Product Let the chiller run 30 minutes before loading it with product the first time When loading the chiller n Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum load of 20kg per shelf Remove some product if the shelves are flexing Do not let anything overhang the shelves because this might stop the doors from shutting or even break something SKOPE B600 2 B600G 2 Introduction Self Learning Motion Sensor amp Door Switch EMS Controller Operations The Energy Management System EMS controller is located inside the r

Download Pdf Manuals

image

Related Search

Related Contents

ZyXEL ZyWALL USG 1000  Samsung 19-inčni LED monitor sjajnog crnog dizajna Priručnik za korisnike  - Mobiletech Blog  Manhattan USB to ExpressCard Adapter  Dr. Rodríguez Vivas Roger Iván - Campus de Ciencias Biológicas y  Telex Car Speaker 1135-2907 User's Manual  SOBRE AUTONOMIAS DIRIGIDAS E VESTÍGIOS DO PASSADO  Mr. Coffee BMLD User's Manual  KA-004 Teste e Simulador de Sensores. Introdução: O KA  Samsung GT-S5250 Керівництво користувача  