TB025 - Rain Master Control Systems

image

Contents

1. PCDX2 MY O40 fm NEUTRAL Ss UNE BLACKS GROUND IGREENI ORAN YGE rye lI eeawe j GROUND i LS SSS EV GROUIND ROD C CONNECT GROUND WIRE TO GROUND Y LUG INSIDE CONTROL CABINET AND OTHER END TO 5 8 x 8 COPPER CLAD gt GROUND ROD CONNECT USING PROFER z CONDUIT TG CODE nO E CONNECT 120V 50 40HZ SUPPLY LINE TO TRANSFORMER WARES WITHIN THE COMDULET PAIS Part No 500508 Rew A RAIN MASTER IRRIGATION SYSTEMS 2510 8 POYal AVENUE SPAI VALLEY Ca 03063 905 527 4499 Figure 2 500508 Revision A S Technical Bulletin 025 Sheet 6 of 7 RAIN IVIASTER 3910 B Royal Avenue Tel 805 527 4498 Simi Valley CA 93063 Fax 805 527 2813 ATTACHMENT C Intermatic AG2401C IND Secondary Surge Arrester The Intermatic AG2401C IND Secondary Surge Arrester protects electrical and electronic equipment from transient voltage surges which can enter via the main power supply line It is designed to be hardwired into power circuitry and mounts easily on the irrigation controller power box This is a UL listed device Figure 3 AG2401C IND End of Bulletin oy Technical Bulletin 025 Sheet 7 of 7 RAIN IVIASTER 3910 B Royal Avenue Tel 805 527 4498 Simi Valley CA 93063 Fax 805 527 2813
2. volts DC and a surge current rating of 20kA Next a series of inductors of 100 micro henries provides high impedance to the fast rise time pulses Finally a high speed solid state transient suppressor with a breakdown rating of 56 volts at 1000A absorbs the remaining transients Both of the suppressors are returned to earth ground through the circuit board mounting hardware The output triacs are rated at 400 volts and are protected against transient turn on with a resistor capacitor network For additional protection in the off season disconnect the interconnecting cables between the controller and the lightning protection boards Disconnecting the AC power will also help protect the transformer If the controller has a battery disconnect it to prevent damage due to complete discharge Record your watering programs for easy S eae rs Technical Bulletin 025 Sheet 3 of 7 Rain EVE STER 3910 B Royal Avenue Tel 805 527 4498 roe es Simi Valley CA 93063 Fax 805 527 2813 startup in the spring All Evolution and RME controllers are available with a heavy duty lightning and surge option This can be specified by appending a T transient to the controller part number Example A standard wall mount 24 station controller without heavy duty lightning and surge DX24 WM With heavy duty lightning and surge DX24 WMTT transient version All field wiring connections are made the same way regardless of the option specified Atta
3. 2 0 Technical Bulletin Bulletin No 025 RevcC Subject Transient Protection Page 1 of 7 Product Applicability All Rain Master Controllers Engineering Release R A Olson Engineering Release Date July 20 2006 Distribution APPROVED FOR GENERAL RELEASE INTRODUCTION This Technical Bulletin provides a procedure for the proper installation of the controller and a summary of the transient protection options available on Rain Master Irrigation controllers Lightning is a high voltage high current electrical discharge made up of a broad range of frequencies It follows the path of least impedance not the path of least resistance Fifty percent of all lightning strikes will have a first strike level of 18kA 18 000 Amps Subsequent strikes will be less about half Three strikes is the average per lightning strike Although theoretically possible it is economically unfeasible to protect a controller against a direct strike The cost of the protection would be prohibitive Lightning induced transients on the other hand are electrical impulses induced in a conductor by being in the vicinity of a lightning strike It is these potentially harmful voltages and currents that Rain Master has attempted to suppress The closer the strike to the equipment and the longer the attached conductors AC line and field wiring the larger the induced transient will be The voltage from a lightning strike rises very fast typically to its peak in a fe
4. chment A shows a typical output board with illustrated connections The Evolution system has a number of devices to protect the incoming 120 VAC line If additional protection is desired Rain Master can recommend a third party device which mounts inside the Evolution controller and can be purchased from Rain Master The device and mounting information is found in Attachment C 5 0 DOCUMENTS More information on earth grounding of electronic equipment is available from the American Society of Irrigation Consultants ASIC 5 1 For the latest revision of ASIC Guideline 100 2002 and the supplemental grounding specification drawings go to http www asic org design_guides htm ee EENET Technical Bulletin 025 Sheet 4 of 7 RAIN MAST ER 3910 B Royal Avenue Tel 805 527 4498 Simi Valley CA 93063 Fax 805 527 2813 ATTACHMENT A EVOLUTION DX2 MASTER VALVE AND STATION CONNECTIONS MASTER VALVE mea fl l PODX2 M PODX2 OT12 STATION 2 TO MASTER VALVE TO ZONE 2 VALVE RMIS Part No 500509 Rew A RAIN MASTER IRRIGATION SYSTEMS 39108 ROYaL AVENUE SIMI Wall EY Ca 99063 e 805 527 4498 Figure 1 500509 Revision A S MEENE Technical Bulletin 025 Sheet 5 of 7 RAIN IVIASTER 3910 B Royal Avenue Tel 805 527 4498 Simi Valley CA 93063 Fax 805 527 2813 ATTACHMENT B EVOLUTION DX2 AC WIRING DIAGRAM BOX SCHEMATIC SWIEH GROME TRANSFORMER uNE e BLUE f TAC NEUTRAL RUE GROUND
5. cteristics and therefore are better suited for protection of electronic equipment The ground system will consist of one or more properly installed ground rods or plates connected through appropriately sized wire to the controller This is described in detail in each Controller s User Manual The safety green wire ground from the electrical service is NOT suitable for a lightning ground The small wire size long length and questionable connections make it unsuitable for protection against transients The only acceptable grounding method for lightning protection is a properly installed and connected ground rod plate system 3 0 IMPLEMENTATION A single 8 foot copper clad ground rod properly installed is usually sufficient The rod must extend beyond the frost line if possible The rod should be driven in not installed in an augured hole You may core through a concrete pad or foundation It should be located as close as possible to the controller so that the AWG 6 ground wire is as short and direct as possible free of nicks and bends The ground clamp inside the controller should be used as the ground point Be sure to remove any oxide from the copper clad rod before attaching the ground clamp to the rod Be sure all connections are solid and secure Should the 8 foot grounding rod not penetrate completely into the soil it is acceptable to put it into the ground on a slight angle of not more than 45 relative to the vertical position It
6. is important that the rod be a full 8 feet into the ground with only enough of the rod showing to clamp the wire on Circuit impedance is critical to the effectiveness of the ground circuit and cannot be measured in the field in a practical way Proper installation is more important to assure quality results than this measurement Make sure to meet the minimum requirements of the NEC National Electric Code which are a A resistance reading of no more than 25 ohms b A two electrode ground grid For installations that require multiple equipment locations the resistance measurements of the ground circuits should be compared for consistent readings Large discrepancies in the readings allude to different soil conditions soils with different moisture content or improper installation aes Se Technical Bulletin 025 Sheet 2 of 7 Rain MAST ER 3910 B Royal Avenue Tel 805 527 4498 Simi Valley CA 93063 Fax 805 527 2813 NOTE Proper installation will show a ground resistance of no more than 25 Ohms A reading of 5 10 Ohms is desirable If the desired results are not obtained then replace the clamps with permanent welded connections Solder shall never be used to make these connections as it will melt during a lightning discharge 3 1 SOIL TYPES The conductivity of the soil varies greatly with soil type and moisture content Sand may have 100 times the resistance of clay Soil resistivity can be significantly reduced with proper s
7. oil anendments which are commonly referred to as Earth contact or Ground enhancement materials In low conductivity soil such as sand two or three interconnected ground rods should be used Spacing should be greater than the sum of their lengths apart Connection between the rods should be made with strap with a width of at least one percent of its length Example With two 8 foot rods spaced 20 feet apart the width of the strap should be about 2 1 2 inches The straps should be connected to the rods with approved clamps and buried in the soil Where extremely rocky soil prevents the proper installation of driven rods horizontal radials make an excellent lightning ground Using 10 gauge wires just buried install four or more in different directions for at least 50 feet each Proper grounding is essential for the surge suppression circuitry to work on any manufacturer s controller Please ground according to the grounding instructions in Attachment B The ground rod and clamp can be ordered from Rain Master Part Number EV GROUND ROD 4 0 RAIN MASTER CONTROLLERS The Rain Master RME and the Evolution DX2 with Transient Protection Option incorporate additional components to provide increased protection for lightning induced transients The Rain Master controllers have three stage protection Observed from the field wiring side where transients may enter the equipment there is a gas discharge tube suppressor with a breakdown voltage of 90
8. w millionths of asecond This energy must be returned to earth as quickly as possible through a low impedance path At this speed the impedance of the ground system is much more important than its DC resistance Impedance in the ground system is reduced by increasing the surface area of the conductors and decreasing their length The buildup of electrons on the ground system also must be dissipated to prevent dangerous voltages in the equipment The ground system must therefore be of sufficient size to absorb the energy TRANSIENT PROTECTION In order to be rendered harmless an induced transient must be returned to earth ground before harmful energy can enter the equipment The protection components incorporated in the Rain Master controllers rely completely on the external ground path provided during the installation of the controller Technical Bulletin 025 Sheet 1 of 7 Rain EVE ASTER 3910 B Royal Avenue Tel 805 527 4498 IGATION SYSTEMS Simi Valley CA 93063 Fax 805 527 2813 NOTE IT IS ABSOLUTELY IMPERATIVE THAT A GOOD GROUNDING SYSTEM BE INSTALLED Grounding circuits for Irrigation Systems consist of ground rods ground plates copper strips straps and solid copper wire With electro mechanical equipment ground rods provide adequate safety and protection Ground plates both alone or in conjunction with ground rods should be used to protect electronic equipment because ground plates exhibit low inductance impedance chara