Contents

1. 13 E t PON PI WTO RO czw Am TUE WED THU FRI weekdays parameters Editing If the user wants to edit programs 7 9 it is possible to edit the settings for each day separately Press MENU in order to select a day PON parameters for Monday 7 Editing Step 3 assign comfort temperature or economical temperature to particular hours An hour which is being edited is displayed on the controller screen In order to assign comfort temperature press N In order to select economical temperature press V The controller automatically moves on to editing the next hour PON MON Edited hour mint The parameters of the weekly program are displayed at the bottom of the screen hours to which comfort temperature has been assigned are displayed whereas hours to which economical temperature has been assigned are not displayed Example The following screenshot presents daily settings of program no 7 for Monday 2400 0159 economical temperature 0200 0659 comfort temperature 0700 1459 economical temperature 1500 2159 comfort temperature 2200 0059 economical temperature WEEK 02 03 O4 OS OG 15 16 17 18 19 20 21 When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is selected as the current program PON MON l rl 14 ST 292 Users manual V c 7 Pre set comfort tempe
2. Tel 48 33 8759380 48 33 3300018 48 33 8751920 48 33 8704700 Fax 48 33 8454547 serwisQtechsterowniki pl Monday Friday 7 00 16 00 Saturday 9 00 12 00
3. EIER eee eee SS 12 ST 292 Users manual changes When the desired number appears on the screen press MENU the controller returns to the main screen view and the selected program number is set Weekly program number e How to configure particular weekly programs Weekly program allows the user to define the time when comfort temperature and economical temperature will apply Depending on the program number the user may set daily temperature values for all days of the week programs 1 3 for weekdays and the weekend separately programs 4 6 and for each day of the week separately programs 7 9 In order to edit weekly program press MENU until weekly program setting panel appears on the screen 00 01 02 03 04 OS OG 077 08 09 10 Nie 13 415 16 7 18 1920 A ee 23 STEP 1 choose the program to be edited By pressing and holding MENU button the user opens the program editing panel Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters Weekly program number Step 2 Select days of the week If the user wants to edit programs 1 3 there is no possibility of selecting particular days of the week as the setting applies to each day If the user wants to edit programs 4 6 it is possible to edit the settings for weekdays and the weekend separately Press MENU in order to select
4. devices using radio communication the user needs to select a different channel T re VII How to use the controller V a Principle of operation The main task of ST 292 room regulator is to maintain the pre set temperature of the room by sending a signal to the heating device contact opening when the desired temperature is reached In such a situation the heating device is switched off if the regulator is connected to the CH boiler controller the CH boiler enters sustain mode V b Operation modes The regulator offers the following modes of operation e Day night mode In this mode the pre set temperature value depends on the current time of the day The user may set different temperature values for the daytime and nighttime comfort temperature and economical temperature as well as define the exact time of entering day mode and night mode In order to activate this mode press EXIT button until day night mode icon appears on the main screen PON MON a e IM day night Li v7 Becct j mode icon I IT M BY E DUD e Weekly control This mode enables the user to define the time when the pre set comfort temperature and the pre set economical temperature will apply The user may set 9 different programs divided into three groups programs 1 3 daily temperature values are set for all days of the week programs 4 6 daily temperature values are set separately for the weekdays Monday Friday and for the weekend Sa
5. the product must not be thrown out to ordinary waste bins By segregating waste intended for recycling we help protect the natural environment It is the user s responsibility to transfer waste electrical and electronic equipment to the selected collection point for KE recycling of waste generated from electronic and electrical equipment 16 ST 292 Users manual Contents I SE EEE ATE 2 II Description of the device ren EYE 3 Ui CORANOLEFIMEKEANGLUON GER AF n i a a Ti 3 Hika Connection didgralnS wad Ed paii i a a ea 4 IV Receiver for wireless controller s sessssssssssnsunsnssnnnrnnnnennsunnnnunsnrnnnnnnneunenennn 6 V External temperature senSOr uuuunneenenonnnnnnnnnnnnnnnnnn nenn nennen nn aaa PPR Rak RR RR EEEE nun 6 ME FIISESTAM UP PRO asec spatacesaret Go a Ep aiSE ooo GOO EEE EEE 7 VII How to use the controller uaaaa aaa aaa aaa aaa aaa aaa kkk kkk kaka zakk aaa aaa kak kkk SSE EERE 8 V a Principle of operatio ee er SEO 8 V b Operation modes ein cd WEAR EEE RETTET 8 V b Main screen view and description aaa aaa aaa aaa kaka kaka aaa aaa aa aaa aaa kk kkk RAR nn nun 10 MIC Controller UNCUON S ac ai iGO O A EA en EGO io Adio G RKA 11 V c 1 Block diagram of the main menu uuaaaa aaa aaa aaa kaka kaka nn nenn aaa aaa zakk R nenn 11 V c 2 Day OF the weekK ocala OG a r ad Go i Ai r GA 12 VCS MMESEUINO Soa saaeaccesetcandararassaassiaseessertaiiaas testers wadenessscacdarupiaeieeridac
6. Controllers add LL JG TEeSe Em t BE I Safety Before using the device for the first time the user should read the following regulations carefully Not obeying the rules included in this manual may lead to personal injuries or controller damage The user s manual should be stored in a safe place for further reference In order to avoid accidents and errors it should be ensured that every person using the device has familiarized themselves with the principle of operation as well as security functions of the controller If the device is to be sold or put in a different place make sure that the user s manual is there with the device so that any potential user has access to essential information about the device The manufacturer does not accept responsibility for any injuries or damage resulting from negligence therefore users are obliged to take the necessary safety measures listed in this manual to protect their lives and property A WARNING e The device should be installed by a qualified electrician e The regulator should not be operated by children A WARNING e Any use other than specified by the manufacturer is forbidden e Before and during the heating season the controller should be checked for condition of its cables The user should also check if the controller is properly mounted and clean it if dusty or dirty ST 292 Users manual II Description of the device ST 292 room regulator is intended fo
7. caenes 12 NACE NIONE KRONE GE AA OGAE OAI 12 VE DEY MOE asa ae 12 VCO WECKIY Progra Mi en deen E E aaa 12 V c 7 Pre set comfort temperature sssssssssssssrsnenrsnrsnsnrnnrnneneunnnrsnsnrnnennrnrnns 15 V c 8 Pre set economical temperature uusssssnnnnnnnnnnnnnnnnnn nun nun nnnnn une 15 V c 9 Pre set temperature hystereSiS uuaaaa aaa aaa nana aaa kina aaa anna aaa ka nennen nenn 15 V c 10 Selecting wireless communication channel ST 292V2 aaaaaaaasii1111 15 VIII Technical data aaa aaa aaa aan nana aaa aaa nun nn paka kkk n nn nun nenn nnnnn nennen nenn nn nn 16 17 fa Declaration of conformity no 123 2013 Hereby we declare under our sole responsibility that ST 292 230V 50Hz controller manufactured by TECH headquartered in Wieprz 1047A 34 122 Wieprz is compliant with the Regulation by the Ministry of Economy Journal of Laws 155 Item 1089 of August 21 2007 implementing provisions of the Low Voltage Directive LVD 2006 95 EC of January 16 2007 ST 292 controller has been tested for electromagnetic compatibility EMC with optimal loads applied For compliance assessment harmonized standards were used PN EN 60730 2 9 2011 PN EN 60730 1 2012 Date of CE marking 05 2013 ZW Inu w 4 i ra cya a FL PAWEL JURA ANUSZ MASTER W A CICIELE TECH SP 18 ST 292 Users manual 19 wert gt Controllers SERWIS 32 652 Bulowice Skotnica 120
8. ht on the sensor flashes the process of channel change has been initiated Hold the button and wait until the light starts flashing again The number of flashes corresponds to the first digit of the desired channel number Release the button after the desired number of flashes and press it again to set the second digit of the channel number the control light flashes quickly twice Hold the button and wait until the light flashes the desired number of times When the button is released the control light flashes twice the new communication channel has been set NOTE In case of a one digit channel number channels 0 9 set O as the first digit Example 1 28 is the desired communication channel In order to select this channel set the first digit 2 and the second digit 8 Press and hold the channel change button the control light flashes quickly once the process of channel change has been initiated Hold the button and wait until the light flashes two more times the first digit of the channel number 28 Release the button and press it again the control light flashes quickly twice the process of setting the second digit has been initiated Hold the button and wait until the light flashes 8 times When the button is released the control light flashes quickly twice the new communication channel has been successfully set Example 2 7 is the desired communication channel In order to select this channel set the f
9. ion goes on during channel change e red indicates receiver operation e green 2 goes on when the room temperature fails to reach the pre set temperature the heating device is switched on How to change the communication channel Channel 35 is the default communication channel in the room regulator The channel may be easily changed if the current channel is used by other devices To change the channel press and hold the channel change button for about 10 seconds until the green control light 1 goes on Next change the communication channel in the room regulator following the procedure described in part V c 10 The green light on the receiver should go off V External temperature sensor ST 292v2 room regulator may optionally be equipped with an external temperature sensor The sensor should be mounted in a shaded place so that it is not affected by the weather conditions The current temperature value will be sent to the room regulator every few minutes and it will be displayed on the main screen The external sensor communicates with the room regulator via radio signal Both the room regulator and the external sensor are pre configured to operate on channel 35 but the user may easily change the channel if the current channel is used by other devices How to change communication channel ST 292 Users manual In order to change the channel press and hold the channel change button After the control lig
10. irst digit 0 and the second digit 7 Press and hold the channel change button the control light flashes quickly once the process of channel change has been initiated As the first digit is O release the button before the control light flashes again Press the button again the control light flashes quickly twice the process of setting the second digit has been initiated Hold the button and wait until the light flashes 7 times the second digit of the desired number When the button is released the control light flashes quickly twice the new communication channel has been successfully set In case of errors in the channel change process the control light goes on for ca 2 seconds In such a case the channel will not be changed VI First start up In order for the controller to operate correctly the following steps must be followed when starting the device for the first time 1 Insert the batteries WARNING While inserting new batteries the user must not press the touch buttons 2 Connect the regulator with the heating device via a two core cable In the case of ST 292v2 version the two core cable should be plugged into appropriate sockets in the receiver 3 In the case of using a wireless room regulator it is necessary to check if the current communication channel selected in the regulator is the same as in the receiver 35 is the default communication channel in all devices If there is a conflict with other
11. ng V A EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited parameter is flashing whereas the remaining parameters are not displayed Use V A to change the parameter settings Press MENU to confirm the changes and move on to edit the next parameter or press and EXIT to confirm the changes and return to the main screen view Weekly program selection Comfort temperature Economical temperature Hysteresis Channel selection V c 1 Block diagram of the main menu Main Mannu Day of the week Time settings Night from Day from Weekly control Pre set comfort temperature Pre set economical temperature Hysteresis Channel selection 11 fa V c 2 Day of the week After entering the main menu all icons which are not connected with the parameter which is being edited are not displayed The first parameter is day of the week Press V or N until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view PON MON V c 3 Time settings In order to set current time press MENU until time setting panel is displayed on the screen By pressing V or N set the hour and minutes Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen vie
12. ommunication channel ST 292v2 ST 292v2 regulator communicates with the heating device orthe CH boiler controller using radio waves via the receiver In order to ensure effective communication the same channel needs to be selected in both the controller and the receiver in the case of using an external sensor it is necessary to set the same communication channel in this device as well 35 is the default channel in all devices The channel must be changed only ifthere is a conflict with other devices using radio communication cr Y 15 I gE E i Et In order to change the channel press MENU until the communication channel change panel appears on the screen Use V or to set the desired channel Press MENU and hold it for ca 3 seconds to confirm and return to the main screen view or press EXIT to confirm and return to the main screen view VIII Technical data Range of room temperature setting 50 556 Supply voltage Batteries 2xAA 1 5V Contact load 1A 230V 50Hz Operating temperature 5 C 50 C Dimensions 120x94x24 mm Care for the natural environment is our priority Being aware of the fact that we manufacture electronic devices obligates us to dispose of used elements and electronic equipment in a manner which is safe for nature As a result the company has received a registry number assigned by the Main Inspector of Environmental Protection The symbol of a crossed out rubbish bin on a product means that
13. r controlling the heating device e g gas oil or electric furnace or the boiler controller Its main task is to maintain the pre set temperature in the flat by sending a signal to the heating device contact opening when the desired temperature is reached Advanced software enables the regulator to fulfil a wide range of functions e maintaining the pre set room temperature e manual mode e day night program e weekly control Controller equipment e touch buttons e front panel made of 3mm glass e built in temperature sensor e batteries Controller versions e vi wired without backlight e v2 wireless with temporary backlight It may be optionally equipped with a wireless external sensor This controller version cooperates with an additional Signal receiver installed near the heating device e v3 wired with temporary backlight III Controller installation The controller should be installed by a qualified person ST 292 controller may be installed as a panel mountable on the wall u TE E k E III a Connection diagrams The room regulator should be connected to the heating device via a two core cable as naaa MM Urz dzenie grzewcze 1 Diagram ST 292 regulator connected directly to the heating device Sterownik kot a CO 2 Diagram ST 292 regulator connected to the CH boiler controller zagyac Urz dzenie grzewcze max 1A 3 Diagram ST 293 reg
14. rature Pre set comfort temperature is used in weekly control mode and day night mode Press MENU button until the comfort temperature change panel appears on the screen Press V or N to set the desired temperature Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view p Z EL V c 8 Pre set economical temperature Pre set economical temperature is used in weekly control mode and day night mode Press MENU button until the economical temperature change panel appears on the screen Press V or N to set the desired temperature Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to je the main screen view m ET V c 9 Pre set temperature hysteresis Room temperature hysteresis defines the pre set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C Example Pre set temperature 23 C Hysteresis 1 C The room regulator reports that the temperature is too low only when the room temperature drops to 22 C In order to set the hysteresis press MENU until the hysteresis setting appears on the screen Use V or N to set the desired hysteresis value Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to 1 the main screen view Coc C gt V c 10 Selecting wireless c
15. turday Sunday programs 7 9 daily temperature values are set for each day of the week separately MON Weekly control Fran TEE Rt X lt w k N li i a icon i oO Sn gt p D I i L CEN lt a Les E Tiaa err s Dub Parameters of the current Number of the current weekly weekly control control program PASE program The display shows the hours when the comfort temperature applies In the remaining time period economical temperature applies ST 292 Users manual e Manual mode In this mode the pre set temperature is adjusted manually from the main screen view with the use of these buttons AA Manual mode is activated when one of these buttons is pressed When the manual mode is activated the previous operation mode enters sleep mode until the next pre programmed temperature change Manual mode may be deactivated by pressing EXIT button Example 1 manual mode activation in Day night mode When Day night mode is active the user changes the pre set temperature by pressing W AN which automatically activates manual mode The controller returns to Day night mode when daytime changes into nighttime or the other way round or when the user presses EXIT PON M ON zi Fr IN AI ILIBT Example 2 manual mode activation in weekly control mode When weekly control is active the user changes the pre set temperature by pressing M N which automatically acti
16. ulator connected to the heating device with load up to 1A ST 292 Users manual g 6 STYCZNIK LE Pr A I f j zum mE Kill T f ill 1 Urz dzenie N grzewcze 230V AC 4 Diagram ST 292 room regulator connected to the heating device with load above 1A STYCZNIK i Kg BEI LE EDA RE AN N 39 es ye H Fi Urzadzenie akg grzewcze 230V AC 5 Diagram ST 292 room regulator connected to a three phase heating device In the case of wireless connection the diagrams presented above should be used the two core communication cable should be connected to appropriate sockets in the receiver Urzadzenie ewcze lub sterownik z 7 kot a fa IV Receiver for wireless controller ST 292v2 regulator communicates with the heating device or the CH boiler controller via radio signal sent to the receiver The receiver is connected to the heating device or CH boiler controller via a two core cable whereas the communication with the room regulator is performed wirelessly via radio signal lampka kontrolna zielona 1 lampka kontrolna czerwona lampka kontrolna zielona 2 przycisk zmiany kana u The receiver has the following control lights e green 1 indicates data recept
17. vates manual mode The controller returns to weekly control mode when according to the weekly schedule economical temperature changes into comfort temperature or the other way round or when the user presses EXIT PON MON SEEN EEE e WI suk LIE LIG Ss CL ERN icon med a GW a EU E07 os 090 ne w 6 y 819 20 07 08 09 10 N le 13 4 15 16 17 18 19 20 fa V b Main screen view and description The user operates the device using touch buttons While one parameter is being edited the remaining icons are not displayed AWN CZW PI SOB IS THU FRI Current operation mode PRA 00 NI 0 a weekly b manual c day night Current temperature of the room Parameters icons Temperature information if this icon is displayed the pre set temperature has been reached If the icon is flashing the pre set temperature of the room has not been reached Day of the week External temperature available only when the wireless version of the controller ST 292v2 is used together with the external temperature sensor ST 291 Pre set temperature of the room Time Battery level Buttons for introducing changes 10 ST 292 User s manual Graphic icons Night from Day from Weekly control settings Z To Pre set economical temperature active EY of Kt Pre set comfort Ar temperature active V c Controller functions The user navigates the menu structure usi
18. w V c 4 Night from This function enables the user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appears on the screen By pressing V or N set the hour and minute of night mode activation Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view ru c co co V c 5 Day from This function enables the user to define the exact time of entering the day mode When Day night mode is active comfort temperature applies at daytime ey To configure this parameter press MENU until Day from setting appears on the screen By pressing V or N set the hour and minute of day mode activation Press MENU to confirm and move on to the next parameter or EXIT to confirm and return to the main screen view V c 6 Weekly program This function is used to change the current weekly control program and edit the weekly programs How to change the current weekly program number When weekly control is enabled see V b Operation modes the current program is activated In order to choose the program number press MENU until weekly program setting appears on the screen By pressing and holding MENU button the user opens the program selection panel Each time the user holds the MENU button the program number SEIFE

Download Pdf Manuals

image

Related Search

Related Contents

Dicota LadyAllure 15"  Betriebsanleitung  Dynamode HDMI-SP-2 video splitter  Miele KWT 1603 Vi Operating and Installation Instructions  NORVAL - Pietro Fiorentini  La Valeur Relationnelle Ajoutée Intégrale (V.R.A.I.    3 - Láminas y Aceros de Yucatán  優しい暮らしのヒーリングパートナー「ユメル」新発売!  Kit Manual - Alere Technologies GmbH  