Home

KEYTEC User`s Manual

image

Contents

1. may need to be mounted higher when using on flat panel displays as described in Hardware Installation Manual Virtual line between 2 receivers Maintain two lines Maintain two lines in parallel os in parallel oo oO gt main in 2cm away a i Projected Screen Projected Screen Must be placed inside of 2 receivers Must be placed inside of 2 receivers E USB cable connector USB cable connector Example for Whiteboard Example for Wall mounting 3 2 Calibration 3 2 1 Open MINT Control Double click Mint control to open the control panel For the first time calibration after the hardware setup click initial setup For recalibration in the future click screen calibration 3 2 2 Quick Setup In the next screen click Next to continue You will need to select Quick setup or Fine setup Quick setup is normally recommended If you experience difficulty of achieving the accuracy of touch you may run Fine setup 2 3 2 3 Verify the receivers locations ha Place PEN at low end point of blue light of Left receiver and Press it continuously till RECOGNIZED is displayed Note Always hold the pen perpendicular to the screen surface to click 3 2 4 Screen calibration Follow and touch the center of each circles appeared on the screen to complete the calibration process Check the accuracy of touch Recalibrate if necessary 3
2. 2 5 Fine setup If Fine setup is selected you will need to touch each X appeared on the top of the screen to complete calibration process x x x x x x x x x Click x mark indicated by arrow Once the Fine setup is completed successfully screen calibration starts automatically Click each circle as described in 3 2 4 lf you got Failed message click REINITIALIZE and repeat this step till you get success message If you fail to do fine setup continuously please check the hardware setup 4 Options for ACEeBoard setup 4 1 Information TAB Here you can choose your preferred language or update MINT software T informati T E FENonPFC v3 0 0 0000 Update W autocheck for updates Language Connected Device ACE eBoard Cancel 4 2 Option TAB You can use various options for your preference during MINT interactive session beehorcrrnaatiaet Option Fuig Viteng Anta Plarvuiil nics THe eee Pin Pmpety Pen touch Bruen Factor Enh Shape P mar l f Hrimh Biri os i ore J F abon hetal Med Hist SiH R idhy soh Shape CH Wia Cars M Gross Gair kai praia JR Lance End Pen Touch adjusting intensity of brush effect Brush Factor adjusting thickness at start and stop point for brush pen Brush Shape selecting brush shape or felt shape Pen Speed adjusting pen speed As bar goes toward left side pen speed is getting faster but writing quality
3. KEYTEC User s Manual ACEeBoard Software Installation 1 Preparation 2 Install new driver MINT Control amp ACEeBoard software MINT Interactive 3 Calibration 3 1 Preparation 3 1 1 Installation Location 3 1 2 Infrared Interference 3 1 3 Check Connection 3 1 4 Check Receivers Mounting 3 2 Calibration 3 2 1 Open Mint Control 3 2 2 Quick Setup 3 2 3 Verify the Receivers Locations 3 2 4 Screen Calibration 3 2 5 Fine Setup 4 Options for ACEeBoard set up 4 1 Information TAB 4 2 Option TAB Revision 110722 a0 220 0 EE 320 s 2D wis m 2 80 m 1 Preparation lf there is a previous version of MINT Interactive already installed on your computer please remove it before new installation Click Start gt Programs gt PNF gt MINT gt uninstall MINT 2 Install new driver MINT Control amp ACEeBoard software MINT interactive BA MINT ActiveLink Insert the installation CD into CD ROM Then Installation menu will pop up automatically You may Install MINT software on your computer recommended or Launch MINT interactive directly from the CD MINT Interactive If installation menu does not pop up automatically please execute POPStarter exe manually from the installation CD J When execution warning message is displayed on Windows Vista Windows 7 please ignore it a Click Install to start the installation After installation is completed cl
4. ick Launch Install finish Two icons will be added to the desktop ActiveLink ae ee yg MINT Interactive E at sobre rinse br cntnocd us wibout MMAR Bs a Shortcut E Shortcut Language e 3 KB 3 KB Ean E O See 3 Calibration Calibration is always necessary after initial hardware installation or repositioning the receivers or changing the size of projected image or whenever you want to fine tune the accuracy 3 1 Preparation 3 1 1 Installing location Do not install ACEeBoard too close to operating machinery which generates noise 3 1 2 Infrared interference ACEeBoard uses Infrared as a reference signal therefore external Infrared source might interfere with the functions of the ACEeBoard Itis better to turn off other infrared devices on your computer before using ACEeBoard For Windows PC you can temporarily disable infrared devices found in device manager such as IR data port IR touch screen etc 3 1 3 Check connection Double click and open the MINT Control Check if the ACEeBoard is connected Under information tab your should see eBoard as connected device If not try to connect the cable to another USB port If itis connected through a USB hub try connecting it to computer s USB port directly Exit MINT Control and restart it 3 1 4 Check receivers mounting The computer image must be projected within the two receivers The receivers should be mounted at least 1 2 5 cm above the projected image area They
5. is getting worse and vice versa Station Install Position Not applicable to ACEeBoard Shape of Mouse Cursor Not applicable to ACEeBoard Cursor position Not applicable to ACEeBoard

Download Pdf Manuals

image

Related Search

Related Contents

Boletim de manutenção  Canon H323 User's Manual  QUALITE DES INTRANTS AGRICOLES ET MISE EN  AKG Acoustics CGN321 STS User's Manual  Médicaments  Animation Tech LifeView TV Walker QQ User's Manual  dreamGEAR Quick Shot Pro for Wii  Samsung Belaidis garsiakalbis F60 Vartotojo vadovas  Samsung RSJ1KERS Manuel de l'utilisateur  

Copyright © All rights reserved.
Failed to retrieve file