1. CAPILLARY TUBE PUNCTURE OR BREAKAGE INDICATES THAT TEMPERATURE LIMITER FILLED WITH LIQUID LEAKS WHICH RESULTS IN rae ABNORMAL OPERATION OF THE GH10PA CONTROLLER IN CASE IF THE ABOVE MENTIONED DEFECT IS FOUND IT WILL BE NECESSARY TO DISCONNECT TEMPERATURE LIMITER FROM THE GH10PA CONTROLLER REMOVE IT AND REPLACE WITH A NEW DEVICE PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 9 CONNECTING DEVICES TO THE GH10PA CONTROLLER OUTPUTS INPUTS 14 L Fan P2 50 51 Boiler temperature T1 12 N Fan P2 52 53 Feeder temperature T2 11 L Burner feeder P1 54 55 Flame sensor C1 09 N Burner feeder P1 55 56 57 Fuel level sensor C2 06 L CH pump P4 05 N CH pump P4 08 L Container feeder P5 07 N Container feeder P5 04 L Heater P3 03 N Heater P3 02 N Power AC 230V 01 L Power AC 230V F 3 15A 250V Un 220 230 VAC PPUH GECO Sp z 0 0 Imax 10A E C oO 32 060 Liszki Cholerzyn 376 tel 48 12 6369811 fax 6362002 Container Feeder www geco pl e mail geco geco pl 11 Burner Feeder Fan STB Model MGH1 Boiler temperature Sn 0000 Prod Date 08 11 TS a Fiane dbnit 55 56 57 Fuel level sensor T Made in Poland 3 NTC NTC m 4 sel Connection LIC CH 52 53 55 58
2. MANUAL FOR CONTROLLER GH10PA Geco P To sicing FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS Program version 01 USER MANUAL We request that users carefully study applicable Instructions before connecting and starting up any of our products Should any doubts arise please contact our Company between 8 a m and 4 p m Attention At the bottom of each page you will find last document s update date Please always use the most recent version of the Instructions which is available free of charge and will be mailed to you if ordered GH10PA USER MANUAL PAGE 2 TABLE OF CONTENTS 1 INTRODUCTION cr sessacsesscdess 3 Dis IGRAPHICSVIMBOUS SU te de cte ium eui aeons he 3 1 2 KEYBOARD AND FUNCTION zes Et t EA te de e cedet vac ate aan 3 1 3 DEVICE OPERATION INDICATORS Goa eite agde e as Er Ee b ewes OOOO ea 4 2 c m5igisudilrm e M 4 3 TECHNICAL 55 3 esee eere xo oc cd ees ce veo ees ae eoru aue eoe WE Pady a P UNE emen 5 4 ELECTRICAL SYSTEM AND CONNECTION RULES 5 5 QUICKSTART t TE A T E T A E EE E AT 6 6 OPERATION OF THE GH 10PA PU st eese eo pane uere e ee PN EON Ve e Re ose sese Er Ve EP NUR 8 6 1 SYSTEM GONHGURANO E es mutat coma tak AAAA ZA M ZARA dane cd IVO aeq 8 6 2 AUT
3. PAGE 11 6 3 Manual operation mode Pressing causes the Controller to switch from automatic to manual mode and immediately deactivates the fan the feeder and the pump In this mode you can manually and independently activate and deactivate the fuel feeder and the fan To do this follow the scheme below STEP 1 STEP 2 gt A Controller Burner feeder Fan indicates water er 5 E Emperature Lower Ka key indicator lights Upper key indicator lights measured on the boiler up Press the key again to up Press the key again to deactivate the feeder and the deactivate the feeder and the indicator indicator In the manual operation mode you can also activate the CH pump and the container feeder To x activate the CH pump press the following keys simultaneously s The CH pump activation and operation are indicated by means of a vertical line on the left side of the display in the upper sign segment on the Controller main display screen gt section 1 3 page 4 5 ES s To activate the container feeder press the following keys simultaneously container feeder activation and operation are indicated by means of a horizontal line on the left side of the display the lower sign segment on the Controller main display screen section 1 3 page 4 6 4 Viewing temperatures After pressing the display shows water temperature at the boiler outlet Vie
4. screen will appear EB Geco oj SE PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 7 Press push button A The following screen will appear Geco O OPA IE and the controller will start automatic operation based on preset factory parameters Table 1 Factory settings chart User Factory Description a Se UO Boiler preset temperature Lo fa oe Fan speed PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 8 6 OPERATION OF THE GH10PA 6 1 System configuration CH cycle Water container Fig 1 Central Heating circuit INPUT OUTPUT T1 Boiler temperature P1 Burner feeder T2 Feeder temperature P2 Fan C1 Flame sensor P3 Heater C2 Fuel level sensor P4 CH pump P5 Container feeder PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 9 6 2 Automatic operation mode By pressing A you can enable the automatic operation mode the Controller lights up the upper indicator on W 6 2 1 Firing up This mode of operation is indicated by the blinking of the upper indicator on A Firing up consists in controlling the burner feeder the fan and the ignition heater so as to switch to the Automatic Operation Mode if F34 0 then the ignition heater cycle is skipped Control
5. the Surface Mount Technology SMT It is designed to control the main Central Heating CH water circuit Control parameters can be adjusted to the current operating conditions and boiler type The Controller includes a system protecting it from power outages and various other disturbances The GH10PA Controller is fitted with e inputs 1 forboiler output water temperature measurement NTC sensor 2 for fuel feeder temperature measurement NTC sensor e adigital input 3 for connecting flame sensor 5 for connecting fuel level sensor It also contains five outputs allowing direct connection of 230 V AC devices i e the fan the burner feeder the container feeder the CH circulation pump and the ignition heater IT IS ABSOLUTELY NECESSARY TO DISCONNECT THE CONTROLLER FROM THE MAIN DURING STORMS PPUH GECO Sp z Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 5 3 TECHNICAL DATA Working voltage 230V AC 10 15 Resistance characteristics Working temperature from 5 C to 40 C for NTC sensors Humidity from 20 to 80 RH NEW M ae Fan and Feeder protection 3 15A 0 7174 89 Sensor type NTC 2 2kQ 10 4374 83 Temp sensor operating range 0 C 100 C 20 2747 10 30 1774 91 Maximum 40 1172 09 eure continuous load 50 795 08 CH pump 1A 250W 60 547 95 Container feeder 1A 250W 70 384 62 Burner feeder 1A 250W 80 2
6. 1 1 Graphic symbols Symbols intended to indicate and at the same time emphasize the importance of text containing information that warns against dangerous situation have the following graphic forms Warning This symbol is used when it is necessary in described instructions to follow the sequence of carried out operations The unit may be damaged or destroyed in case of any error or proceeding in discord with the description Important This symbol indicates information of particular importance Reference This symbol indicates occurrence of additional information in a chapter 1 2 Keyboard and function PROGRAM SIGNALING AUTOMATIC MODE AUTOMATIC MODE SIGNALING ON OFF MAINTAIN MODE FEEDER MANUAL SWITCHING DOWNWARD VALUE CHANGE FAN MANUAL SWITCHING UPWARD VALUE CHANGE MANUAL MODE PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 4 1 3 Device operation indicators The operation of particular devices is indicated by means of LED lights placed next to the keys gt section 1 2 page 3 and by the first segment of the display Individual lines on the display when lit up indicate the operation of the CH pump the heater and the container feeder see the figure below l CH pump operation heater operation e container feeder operation 2 GENERAL FEATURES The GH10PA Controller is a microprocessor based device manufactured using
7. 57 Fig 3 Diagram of connections between equipment sensors and the GH10PA controller ANY ADDITIONAL EQUIPMENT MAY BE CONNECTED TO THE GH10PA CONTROLLER ONLY BY PERSON LICENSED TO PERFORM ELECTRICAL INSTALLATION WORKS GH10PA USER MANUAL PAGE 17 10 INFORMATION ON LABELLING AND COLLECTION OF WORN OUT ELECTRICAL AND ELECTRONIC EQUIPMENT CAUTION This symbol placed on the product or its packaging indicates the need for selective collection of worn out electrical and electronic equipment It means that this product should not be disposed of with other household wastes Proper disposal of aged and worn out electrical and electronic equipment will help to avoid potentially adverse effects for environment and human health It is the user s responsibility to collect worn out equipment separately and to return it to an authorized disposal company PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 P P U H Geco Sp z o o Ltd Cholerzyn 376 32 060 Liszki Poland ph 48 12 636 98 11 636 12 90 fax 48 12 636 20 02 http www geco pl e mail geco geco pl
8. 75 86 Fan 1A 250W 90 202 37 Heater 3A 750W 100 149 16 In case of connection controllers with contactor or intermediary relay User should apply dedicated to the outputs quencher CH construction for example varistor construction If this kind of protection will be omit This can cause incorrect working or damage outputs in controller 4 ELECTRICAL SYSTEM AND CONNECTION RULES Boiler room should be equipped with 230V 50Hz electrical system according to applicable regulations Electrical system regardless of its type should end with a plug in socket equipped with protective contact Using a socket without connected protective contact may result in electric shock The controller needs to be connected to a separate power supply line protected with a properly selected quick fuse and differential current switch anti electric shock It is forbidden to connect any other equipment to this line THE CONTROLLER IS POWERED FROM 230V 50HZ MAINS ANY REPAIRS MAY BE CARRIED OUT ONLY WITH POWER SUPPLY CUT OFF AT THE FUSE PPUH GECO Sp z Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 6 5 QUICK START Carry out the following operations in order to activate the GH10PA controller quickly 1 Connect the unit to the mains plug in power supply cable B B Geco Geco ae ZEER Tor AE Tor SE Switch on the controller using push button The following
9. During the waiting period the display shows time in seconds remaining until the end of the period together with indication of its condition before the power outage e blinking A for AUTO mode e blinking P for MAINTAIN mode e blinking r for MANUAL mode age Respective indicators AUTO wp or MAINTAIN are blinking together with the letters 6 7 Boiler burnout detection 6 7 1 No fuel If during automatic operation the boiler outlet water temperature remains below the F08 setting for period of time set in the F09 setting then the Controller considers the boiler as burned out and enters the AL13 alarm condition 6 7 2 Sudden Drop of Outlet Water Temperature If during automatic operation the boiler outlet water temperature drops by 10 C and during that dropping period the temperature does not rise by 4 C then the CH pump is switched off and the Controller goes into the burnout detection mode The Controller waits for the period of time during which it checks whether a rise of 4 C occurs If YES then the burnout detection condition is stopped and the CH pump if necessary is started If NOT this means that the furnace is burned out the Controller enters the AL13 alarm condition PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 13 6 8 Maximum feeder temperature detection The GH10PA Controller is equipped with an additional option protecting it from fuel
10. OMATIC OPERATION MDDE O A aede qa BER b et db tna RE a OPEM deo ad 9 6 32 MANUAL OPERATION MODE ums eoo paints ot hd clk d de ood ev sebo EV AO Roa DE oT e A 11 6 4 VIEWING TEMPERATURES n SOA EE OERE E EE ENER 11 6 5 ALARMS testi oi nt E ank aie Eh eee ee a eis 12 5 0 SPOWERTAIWRE EE E EE OAZA E A E 12 637 2 BOILEPBORNOUTDETECHON O o seat 12 6 8 MAXIMUM FEEDER TEMPERATURE DETECTION sccscsescssescssssesccnsesccaeseecnssaeseesaesecuesecaesercaesaesaeaeeeeeaseasneags 13 7 USER SETTINGS riseta eiet oasis arestes Enee M 14 7 1 BOILER PRESET TEMPERATURE UO ccsesccceessscececssscececssesececseseececsesesecsessecscsessecsesessecsesaeseesenessecsesseaeees 14 2 FEEDER WORKING TIME E ENES A PAS WIA AENA SE 14 7 3 EEEDER STOF TIME U2 rere rt A ESNEA E NRA NES A A 14 TA MANTAN TIME U3 e treten eee ea mese AAEE EEEE aE 15 7 54 EANISPEED rede coe ertet OE ED eis a RO PED eaten EE 15 8 TEMPERATURE LIMITER STB 40 54 5444 ne no Co n ro ann n na nn ec io ir aoo n gano daw ska ao goo vo n sa eaa aora 15 9 CONNECTING DEVICES TO THE GH10PA CONTROLLER 16 10 INFORMATION ON LABELLING AND COLLECTION OF WORN OUT ELECTRICAL AND ELECTRONIC EQUIPMENT o MO 17 PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 3 1 INTRODUCTION
11. e setting boiler manufacturer setting If during setting the new temperature E CZ none of the following keys EG P is pressed for 15 s the new temperature will not be saved and the Controller will exit the programming mode 7 2 Feeder working time U1 This setting informs the user about the time for which the fuel feeder will be activated in the AUTO mode Settings are within range of 2s to 250s You can change the setting using the following procedure STEP 1 STEP 2 STEP 3 STEP 4 o Go to U1 Save the new The display shows Set the new desired temperature UO parameter value od current setting setting 7 3 Feeder stop time U2 This is the period of time between two consecutive fuel feeds in the AUTO mode Settings are within the range from 5s to 250s You can modify this setting applying a procedure similar to the one described in section 7 2 PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 15 7 4 Maintain time U3 This is the period of time after which the Controller activates the feeder and fan for the period set by the manufacturer for the MAINTAIN mode to prevent burning out of the boiler Settings range is from 5 min to 250 min You can modify this setting in a manner similar to the one described in section 7 2 7 5 Fan speed U4 This set
12. feeder temperature rise above the permissible value to prevent backfires into the fuel feeder The detection is active in the automatic boiler operation mode AUTO MAINTAIN ALARM When the measured temperature exceeds the value set in the F14 service setting the fuel feeder activates for the period of time set in the F16 service setting to eject the ignited fuel from the feeder During the F16 period the fan remains inactive When the time set in F15 service setting elapses the Controller restores the maximum feeder temperature detection process When the feeder T exceeds 90 C the fan is deactivated the fuel feeder is activated for a period of 2xF16 and the display indicates the alarm condition AL11 Maximum feeder temperature exceeded section 6 5 page 12 The Controller remains in the alarm condition until user response IF F14 0 THEN FEEDER SENSOR OPERATION IS DISABLED AND THE CH MAXIMUM FEEDER TEMPERATURE DETECTION FUNCTION IS NOT ACTIVE PPUH GECO Sp z Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 14 7 USER SETTINGS 7 1 Boiler preset temperature UO You can change the boiler temperature setting applying the following procedure STEP 1 STEP 2 STEP 3 The green LED lights up Setthencew desired Save the new on the key MONZA ANA temperature setting The display shows Move the U1 range permitted by the current temperatur
13. ign segment on the Controller main display screen section 1 3 page 4 The Controller deactivates the pump when the water temperature drops to the activation temperature 3 C If the CH pump activation temperature is 40 C then the CH pump deactivation temperature is 37 C 6 2 5 Fan In the AUTO mode the fan operates continuously until the boiler temperature reaches the value set by the user in the UO setting During that period the fan operates at the speed set in the U4 setting Fan activation and operation are indicated by the upper indicator on ej 6 2 6 Maintain operation mode The Controller switches into this mode when the boiler temperature reaches the value set by the user in the UO setting This mode of boiler operation is indicated by the lower indicator on WW The fuel feeder and the fan remain inactive in this mode for the period set by the user in the U3 setting When the period ends the Controller activates the feeder and fan for the period set by the manufacturer in the F20 service setting The fan operates for a period appropriately longer than the feeder for the time set in the F18 service setting in order to fire up the added fuel The Controller exits the MAINTAIN mode and return to the AUTO mode if the boiler temperature drops to the value equal to UO F05 The CH pump operates in the same manner as in the AUTO mode PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL
14. ler without ignition heater support without the need to enable it manually The fan operates continuously providing the output indicated in the F36 service setting and the Controller additionally indicates whether it activates the feeder the fan or the heater The heater activation and operation are indicated by means of a horizontal line on the left side of the display in the lower sign segment on the Controller main display screen gt section 1 3 page 4 If the sensor detects fire during firing up sensitivity drops below the value indicated in the F39 service setting the firing up process is terminated and the Controller switches to automatic operation The firing up process follows the scheme below 1 FUEL Fuel container FEEDING t Fan 7 AUT p MATIC Flame detection p FIRING UP 4 Heater PHASE 1 Fan Ed Hame detection Ed 5 BEN UP Fan BEN 2 DO Flame detection AUTOMATIC MODE NO LEGEND G 1 Cycle 1 Cycle 2 GOING OUT ALARM 14 3 Fig 2 Diagram showing firing up process PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 10 6 2 2 Burner feeder In the AUTO mode entering the following values of the service settings F41 1 and F40 0 causes the burner to operate in a continuous manner if other parameters are entered for the service settings F40 and F41 the burner feeder operates according to the val
15. ting determines the fan rotation speed and thus the amount of air delivered It allows adjusting the fan speed according to the type and quality of the fuel used This setting can be set within the range of 1 10 where 1 denotes the minimum speed and 10 the maximum speed You can modify this setting in a manner similar to the one described in section 7 2 8 TEMPERATURE LIMITER STB The GH10PA Controller can be equipped with an additional independent temperature limiter STB via terminals 15 and 16 CE WHEN THE TEMPERATURE LIMITER IS NOT USED TERMINALS 15 AND 16 SHOULD BE SHORTED If due to boiler temperature rise the temperature limiter is activated and opens its terminals it will disable feeder and fan power supply in order to stop fuel and air delivery do the boiler After approximately 5s from limiter activation the Controller indicates the AL1 alarm Return to normal boiler operation is possible when the boiler temperature drops to a level enabling limiter reset temperature level depends on the limiter model used For safety reasons the Controller does not resume automatic operation on its own For the Controller to resume operation you have to after resetting the limiter press Fog pressing LQ for the first time cancels the alarm and disables the Controller pressing for the second time reactivates the Controller pressing causes the Controller to switch to automatic operation mode
16. ues set in the user settings U1 Feeder work time and U2 Feeder stop time Activation and operation of the burner feeder is indicated by the lower indicator on 6 2 3 Container feeder This feeder is activated by entering the setting F41 1 With the setting F40 1 the container is configured to cooperate with fuel level sensor in the burner feeder The container feeder operates only when the burner feeder is active and when the level sensor indicates lack of fuel but for a time not shorter than 5s If the burner feeder is active and there is no signal from the level sensor the container feeder remains inactive If the setting F40 0 is entered the container feeder operates on a cyclical basis according to the values of the user settings U1 Feeder working time and U2 Feeder stop time in the AUTO mode In the MAINTAIN mode the container feeder operates according to the value of the F20 setting The container feeder activation and operation are indicated by means of a vertical line on the left side of the display in the lower sign segment on the Controller main display screen section 1 3 page 4 6 2 4 CH pump In the AUTO mode the CH pump is activated when the temperature of the boiler water is higher or equal to the value set in the F06 service setting factory setting is 40 C The CH pump activation and operation are indicated by means of a vertical line on the left side of the display in the upper s
17. wing the feeder temperature and flame sensor measurement is available in the AUTO and MAINTAIN modes but only if the feeder sensor and or flame sensor are properly enabled B 7 Press 3 to view the feeder temperature Press the key again to exit the view You can also wait for automatic exit 10s from pressing the key Press to view the flame sensor measurement Press the key again to exit the view You can also wait for automatic exit 10s from pressing the key PPUH GECO Sp z o o Ltd Issue III SINCE JANUARY 2013 GH10PA USER MANUAL PAGE 12 6 5 Alarms The Controller uses 7 different alarms In each alarm condition the Controller displays the alarm number and activates the alarm sound output In case of several alarm conditions occurring simultaneously their numbers are displayed in sequence You can exit an alarm condition only by pressing except the AL12 alarm Alarms e AL1 STB activated or fuse blown e AL2 Boiler water outlet temperature sensor failure e AL3 Feeder temperature sensor failure e AL11 Maximum feeder temperature exceeded e AL12 Boiler overheating e AL13 Boiler burnout e AL14 Burnout when firing up 6 6 Power failure After power failure the Controller resumes operation according to the condition it was in before the power failure The Controller waits 1 minute for the mains power parameters to stabilise and then resumes operation with the previously entered settings