Home
COUVERTURE SOPRO 717 First multilingue:Mise en page 1.qxd
Contents
1. The intra oral camera does not need any maintenance if it is used according to the manufacturer s use and cleaning instructions Before first using it it is imperative to follow the complete disinfecting procedure Any intra oral camera returning from servicing or maintenance should be completely disinfected before being used WARNING Do not use products containing Ammoniac trichloroethylene e Dichloroethylene Ammonium hydrochlorid Chlorinated and aromatic hydrocarbon Ethylene dichloride Methylene chloride Ketones Using products containing these chemicals risk deterioration of plastic parts WARNING Do not directly spray disinfecting products on SOPRO products WARNING Infection control procedures must be observed when handling the camera or using accessories such as dental barriers in order to prevent cross contamination risk from one patient to another 2010 03 26 User s manual Sopro 717First 17 ENGLISH 9 1 HANDPIECE OR CONNECTION BOX MAINTENANCE DESCRIPTION RECOMMENDATIONS USE INSTRUCTIONS AND PRECAUTIONS V Take the wipe remove excess X Do not scrub Disinfecting Surface cleaning and moisture and then wipe the Do not rinse disinfecting wipes e g equipment until visible X Do not immerse in a Septol Wipes from cleanliness is obtained disinfecting liquid Pierre Rolland v Allow to dry in the open ai
2. Connect the USB cable to one of the computer USB ports Connect the connecting cable to the handpiece 7 5 SOPRO IMAGING SOFTWARE INSTALLATION elnsert the SOPRO Imaging CD ROM into the driver It will be executed automatically WARNING If the CD ROM does not execute automatically or if the operating system is prior to Windows XP SP1 follow the following instructions Go to the Start menu gt Execute Type D setup exe replace D by the letter of the CD ROM driver And then click on OK The file instantly executes Then follow the steps from the below point A dialog box opens it is the main menu window allowing the installation of a certain number of programs related to SOPRO Imaging application NOTE Clicking on the key Browse this CD ROM accesses a Windows browse window from which it is possible to consult the whole content of the CD ROM At the CD ROM root there are the files allowing an automatic launch and or a manual setup Located in the directory Document and its subdirectories are all the documents about the Sopro Imaging software digital x ray systems intra oral cameras and SOPROLIFE system These documents are in PDF format Be sure to correctly install Acrobat Reader in case of reading difficulties The Drivers directories contain the drivers necessary for the use of hardware accepted by SOPRO Imaging Sopix system SOPRO cameras in USB 1 and USB 2 Hasp protection
3. SOPRO 71 USER MANUAL y ACTEON Imaging cooocoooocooOo ENGLISH CONTENT FOREWORD sea e RD e va er eR T der eue Oe eee Ue Dues gae 2 DENTAL CAMERA INTRODUCTII N 5535323 3 SAFETY INSTRUCTIONS 55s 5255 ext een at e reae a 4 REGULATORY REQUIREMENT S is 5556255675 a EX tne 5 INSTALLATION porre rn ento 10 CONNECTING TO A VIDEO SCREEN eee eere tttm 11 CONNECTING TO A COMPUTER Fine a 12 DESCRIPTION OF THE CONNECTION BOXES 15 MAINTENANCE eee vt nee ae uen es 17 AFTER SALES SERVICE RI aD TU OH 19 TECHNICAL FEATURES araura eo PENES EXE DUE SE EXE EE Ye 22 2010 03 26 User s manual Sopro 717First ENGLISH FOREWORD Congratulations on your purchase of SOPROLIFE To optimize the use of this device whilst taking all the necessary precautions we recommended you read carefully and follow the owner s manual Please carefully consider the messages CAUTION WARNING and NOTE when using the system CAUTION the term CAUTION describes potential incidents likely to jeopardize safety Ay WARNING the term WARNING refers to the incidents likely to disturb the smooth running of the imaging system NOTE the term NOTE high
4. OPERATION OF SOPROTOUCH IMAGE FREEZE ON SOPRO 717 FIRST When powering on the camera automatically selects the single image mode e switch to four image mode press SoproTouch for more than three seconds until a black flash appears on the screen or if you have chosen to use a footswitch press it for more than three seconds Perform the same procedure to switch back to single image mode In single image mode you just have to slightly touch SoproTouch or briefly press the footswitch once as soon as the desired image appears on the monitor The image is automatically stored in the camera and displayed on the screen If you want to return to direct mode you just have to slightly touch SoproTouch lt once more or press the footswitch Another little gentle touch on SoproTouch or press on the footswitch will freeze another image by deleting the previous one In four image mode the image is stored in one of the quarters of the screen when you slightly touch SoproTouch or press the footswitch and remains displayed on the screen Another little slight touch on SoproTouch x or press of the footswitch will return the image to direct mode A third little slight touch or pressof the footswitch will store a second image in another quarter of the screen and so on until four images are obtained 2010 03 26 User s manual Sopro 717First 11 ENGLISH CONNECTING COMPUTER 7 1 REQUIRED CON
5. Respect the standards relative to waste disposal in force in the installation country For more details about the 2010 03 26 User s manual Sopro 717First 5 ENGLISH device treatment recuperation and recycling please contact your dental device distributor or failing that the group ACTEON site so that you can be informed of the procedure 4 5 ELECTROMAGNETIC COMPTABILITY Guide and declaration of the manufacturer electromagnetic emissions SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment SOPRO device only uses radio energy for its internal functions Therefore its RF emissions are very low and are unlikely to cause interference with nearby electronic devices RF emissions Class B CISPR 11 SOPRO device may be used in all domestic TEN environments including the ones directly Harmonic emissions EN 61000 3 2 Not applicable connected to the public low voltage powe distribution network used to supply household Voltage fluctuations Flicker Li buildings EN 61000 3 3 Pp 6 Sopro 717First User s manual 2010 03 26 ENGLISH Guide and declaration of the manufacturer electromagnetic immunity SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment Pe CEI 60601 Electromagnetic environment Immunity trial Compliance
6. correctly positioned on the camera head With a computer No image displays on the Defective power Verifier que l alimentation secteur est screen and the camera LEDs supply connect e au r seau et au boitier de connexion are not on connection problem 2 V rifier que le cable de liaison est bien connect la pi ce main et au boitier de connexion Configuration Check the camera is correctly set up in Sopro image displays on the screen Imaging please refer to Sopro Imaging user s manual Driver Check the camera is correctly detected in the device driver correct installation of its driver Connection problem 3 Check the USB cable coming from the DOCK is correctly connected to the HUB An image displays on the eck the camera configuration in the Sopro Imaging screen but the quality is not configuration software brightness contrast saturation etc satisfactory Please refer to Sopro Imaging user s manual An image displays but it is not Rotating ring Check the rotating ring is correctly positioned really clear blurry Extra oral amp Intra oral macro 5 e Hygienic protector 12 Check the hygienic protector is correctly positioned on the camera head 20 Sopro 717First User s manual 2010 03 26 ENGLISH The dental camera should be sent to us in its totality connection box handpiece cables Please enclose your packing list with a brief explanatory note relative to the
7. key The directory SOPRO Imaging contains the SOPRO Imaging installation program The directory Tools contains e Click on Install SOPRO Imaging A window displays select the desired language during the installation process A dialog box opens it displays the software license to be entirely read to continue the installation Once the terms are read click on Next By default the SOPRO Imaging software will automatically install in the directory C Program Files SOPRO Imaging To start installing the software click on Next Once the installation is completed a dialog box displays Click on Finish 2010 03 26 User s manual Sopro 717First 13 ENGLISH WARNING To obtain the best performance possible when using the SOPRO Imaging software it is recommended to install DirectX 9 0c In order to do this click on the key Install DirectX 9 0c and then follow the displayed instructions DirectX 9 0c is a Microsoft product In case of difficulties when installing this product consult the information provided by this editor In order to ensure maximal compatibility with all the installed systems computers Windows and word processing version it was decided to provide the documents available on the CD ROM in PDF format This format developed by ADOBE Company can be read with the Acrobat Reader service program If Acrobat Reader is not installed on the computer or the version is not rec
8. level Severity level Guide 6 kV when in contact 8 kV in the air 2 kV for the feed cables 1 kV for the input output cables Differential mode 1 kV mode 2 kV for 10 ms lt 5 UT 10 ms for 100 ms 40 U 100 ms for 500 ms 70 U 500 ms for 5s lt 5 Ur 55 Magnetic field with Note is the power voltage nominal value applied during the trial he floor should be wooden concrete or tile If the floor is covered with synthetic material the relative humidity should be at least 30 he main power supply quality should be one of a traditional commercial o hospital environment he main power supply quality should be one of a traditional commercial o hospital environment he main power supply quality should be one of a traditional commercial o hospital environment If the user of SOPRO device requires it to continue to operate during main supply outages it 15 recommended SOPRO device is fed b inverter or a battery he magnetic field with the networ frequency should be at a characteristic level of a location in a traditional commercial or hospital environment 2010 03 26 User s manual Sopro 717First 7 ENGLISH Guide and declaration of the manufacturer electromagnetic immunity SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment 60601 Compliance Electr
9. noticed defect If some parts constituting the camera happen to break it is imperative to send in everything so that the defective parts can be replaced When your material is returned to you you should check its condition and note any reservations on the delivery slip if necessary You will then have 48 hours to confirm by registered letter sent to the carrier After 48 hours the carrier will be able to deny these reservations If any material we sent was damaged during transportation the repair charges will be billed either to the carrier if the reservations were made within the period or to the recipient Check as soon as possible that all material is correctly working 2010 03 26 User s manual Sopro 717First 21 ENGLISH TECHNICAL FEATURES SOPRO 717 FIRST e High sensitivity CCD 1 4 Resolution 752 x 582 PAL 768 x 494 NTSC Definition 470 lines Sensitivity 2 lux Lighting eight LEDs Adjustment three preset positions Extra oral Intra oral Macro Non inverted image Image freezing through SoproTouch or footswitch option Viewing angle 70 Cable length 2 5m e Handpiece dimensions L 200 W 28 24 mm Usable part dimensions W 13 x H 8 mm Handpiece weight 75 g DOCK M_USB2 Memory one and four images e Power supply 115 V 230 V 60 Hz 50 Hz 1 PAL or NTSC video output 1 PAL or NTSC S video output 1 digital USB o
10. stored image displays on the screen or the last four if you were in four image mode or the color bar pattern if no image was stored Except for the DOCK USB2 5 3 FOCUSING ADJUSTMENT On the handpiece there is a rotating ring used to focus from 0 to infinite To simplify handling we have preset three positions corresponding to the main dental camera uses Extra oral Portrait Intra Oral 1 to 5 teeth 2M Macro details that cannot be seen with naked eye 10 Sopro 717First User s manual 2010 03 26 ENGLISH CONNECTING TO A VIDEO SCREEN 6 1 CONNECTION OF DOCK M_USB2 e Connect the video cable preferably Y C S video between the connection box and the monitor video input Connect the connecting cable between the connection box and the handpiece f you prefer using a footswitch rather than SoproTouch to freeze the image you just have to connect the footswitch optional to the connection box With this configuration SoproTouch is inhibited Connect the power supply to the outlet and then to the connection box the green indicator light should be on Only use the power supply provided with the connection box 6 2 CONNECTION OF DOCK MU USB2 e Please refer to DOCK MU USB2 integration manual for its connections Connect the connecting cable to the handpiece e Connect the video cable preferably Y C S video between the connection box and the monitor video input 6 3
11. FIGURATION FOR THE COMPUTER To use the Sopro 717 First system you must make sure the computer and its peripherals do not have any use limitation that could concern life safety It should also meet the following requirements USB ports 2 x USB2 0 Hi Speed ports 4 x UB 2 0 Hi Speed ports Graphic board with Nvidia chipset or exclusive video ATI Graphic board 32 MB of unshared Video board LN 256 MB of unshared video RAM compatible with DirectX 9 video RAM compatible with DirectX 9 or higher USB Chipset Intel ou NEC Intel ou NEC Screen resolution 1024 x 768 1024 x 768 or higher Standard 60950 IEC 60601 1 7 2 DOCK M_USB2 CONNECTION Connect the USB cable between the connection box and one of the computer USB ports Connect the connecting cable between the connection box and the handpiece e If you prefer using a footswitch rather than SoproTouch lt to freeze the image you just have to connect the footswitch optional to the connection box With this configuration SoproTouch is inhibited Connect the power supply to the outlet and then to the connection box the green indicator light should be on 7 3 DOCK MU USB2 CONNECTION Refer to DOCK MU USB 2 integration manual e Connect the connecting cable to the handpiece Connect the USB cable between the connection box and one of the computer USB ports 12 Sopro 717First User s manual 2010 03 26 ENGLISH 7 4 DOCK USB2 CONNECTION
12. Y PARTICULAR DAMAGE INDIRECT ACCIDENTAL OR CONSEQUENTIAL NOR FOR ANY DETERIORATION OR DATA LOSS ON A CONTRACTUAL NON CONTRACTUAL OR OTHER BASIS The liability exclusion or limitation for direct or indirect damages does not apply under the regulatory or legal rules in force in some countries and the present exclusion may not apply to a purchaser in those countries 2010 03 26 User s manual Sopro 717First 19 ENGLISH 10 2 IN CASE OF FAILURE PROBLEMS CAUSES SOLUTIONS With a video monitor No image displays on the Defective power Check the power supply is correctly connected to screen and camera LEDs supply the network and to the connection box not on connection problem 2 Check the connecting cable is correctly connected to the handpiece and to the connection box Camera switches on but no e Defective monitor 1 Check the video cable is correctly connected the image displays on the screen power supply monitor and to the connection box e Connection problem 2 Check the monitor is switched on An image displays on the Monitor configuration Check the video monitor configuration is correctly seti screen but the quality is not up brightness contrast saturation etc satisfactory An image displays but it is not e Rotating ring the rotating ring is correctly positioned really clear blurry Extra oral amp Intra oral macro e Hygienic protector 2 Check the hygienic protector is
13. atory agency there is no guarantee about interference likely to occur on a particular installation If the device generates interference with radio communication services which can be determined by switching it off and on the user is recommended to try to correct this phenomenon by taking whole or part of the following measures Change the receiving antenna orientation Reposition the product according to the receiver Take the computer away from the receiver The SOPRO 717 First camera is designed and tested to be used in a home environment class B Group 1 according to CISPR11 standard 4 3 MEDICAL DEVICE VIGILANCE As any medical device this device is subjected to the medical device vigilance dispositions any serious dysfunction should then be the subject of a description to the competent authorities and to the manufacturer as soon as possible and as precisely as possible 4 4 END OF LIFE This device bears the recycling symbol lt s according to the European directive 2002 96 EC about electric and electronic equipment waste DEEE or WEEE By correctly disposing of this device you will contribute to avoiding any damage to the environment and human health The symbol present on the device or on the accompanying documentation indicates this product cannot be in any case treated as household waste Therefore it should be transferred to a waste collection center that handles electric and electronic equipment recycling
14. ent enough click on the key Install Acrobat Reader and then follow the instructions Acrobat Reader is an ADOBE product In case of difficulties when installing this product consult the information provided by this editor 7 6 SOPRO IMAGING SOFTWARE CONFIGURATION WITH SOPRO 717 FIRST CAMERA Refer to the SOPRO Imaging owner s manual that is on the SOPRO Imaging CD ROM in the document directory 14 Sopro 717First User s manual 2010 03 26 ENGLISH DESCRIPTION OF THE CONNECTION BOXES 8 1 DOCK M_USB2 POWER SUPPLY The dental camera power supply is connected to the power outlet The other end of the cord is connected to the dock where the symbol 6 V is located PHIHONG PSA 10R 060 Model or FRIWO MPP15 FW 7555M 06 model The power supply automatically adapts to the electric networks 115 V 230 V 60 Hz 50 Hz 0 5 A The camera voltage is powered by 6V E of a continuous low voltage type 8 2 DOCK MU_USB2 POWER SUPPLY The electrical connection of this connection box should be performed by the installer The dental camera power supply is performed through the connection box that should be connected 24 V 50 Hz 60 Hz 10 VA 8 3 DOCK USB2 POWER SUPPLY The dental camera electrical supply is directly performed through the computer USB port The voltage powering the camera is of continuous 5 V low voltage type 0 5 A 8 4 VIDEO AND USB OUTPUTS This camera has two independent video outputs a compo
15. fore using the camera make sure it does not have any sharp edges The surface temperature in the light emission area can be just above 41 C after several minutes of using it so avoid maintaining this emission area in contact with the patient s mouth e The SOPRO 717 First camera is a product using class 11 LEDs according to IEC 60825 To avoid any ocular risks do not stare directly at the LED s 3 NOTE If the hygienic protection is torn while examining a patient or if the handpiece was infected while withdrawing the hygienic protector it is essential to totally disinfect the handpiece In order to do this please refer to the maintenance chapter 4 Sopro 717First User s manual 2010 03 26 ENGLISH Q REGULATORY REQUIREMENTS 4 1 COMPLIANCE WITH STANDARDS AND REGULATIONS This product was designed and manufactured by a company having an authorized quality system It meets the European directive 93 42 EEC requirements relative to medical devices Therefore it particularly meets electrical safety and electromagnetic compatibility standards IEC CEM 4 2 ELECTROMAGNETIC INTERFERENCE AND ELECTROSTATIC DISCHARGES Electromagnetic compatibility CEM is the ability of electronic device elements to correctly interact in an electronic environment Although this dental camera system was designed according to this compatibility and complies with the electromagnetic interference thresholds established by the regul
16. ion distance given in the higher frequency band applies Note 2 These recommendations may not apply in every situation The electromagnetic wave propagation i modified by absorption and reflection due to the structures objects and persons 2010 03 26 User s manual Sopro 717First 9 ENGLISH INSTALLATION 5 1 CONNECTING Fastening the handpiece holder 1 Choose a smooth area that can be easily accessible for use 2 Use the wipe provided to clean the surface on which you are going to fasten the holder 3 Remove the double sided adhesive tape protection that is on the support place it and then press it into place several times The maximum adhesive performance is obtained after two hours So avoid any stress on the holder during this two hour period WARNING This holder is equipped with magnets that can damage devices sensitive to magnetic fields Make sure you do not install this holder near these devices cathode ray tube video screen magnetic videotapes etc 5 2 FURTHER CONNECTION BOXES OPTIONAL You can install a connection box near each dental chair no limitation You will just have to transport the handpiece from one chair to the other The handpiece holder is intended to maintain the connecting cable connector when the cable is not linked to the handpiece When you disconnect the handpiece connecting cable to take it to another chair or when you put the handpiece on its holder the last
17. lights particular points in order to facilitate the system maintenance or to clarify important information Sopro 717First User s manual 2010 03 26 ENGLISH DENTAL CAMERA INTRODUCTION It is an extra and intra oral camera designed for dental applications It allows the user to see anatomical and pathological details that cannot be seen with the naked eye as well as pathology control and post treatment This camera is composed of a handpiece SOPRO 717 First a connection box DOCK M_USB2 DOCK USB2 or DOCK MU_USB2 and various accessories necessary for it to work SOPRO 717 First 1 handpiece integrating the camera electronics and lighting 1 handpiece holder 10 dental barriers Owner s manual Imaging software demo version DOCK M USB2 e Connection box with integrated image memory and USB2 digital output Power supply 2 5 metre cable to connect the handpiece to the connection box 5 metres and 7 metres optional e S Video Y C cable RCA video cable USB cable DOCK USB2 USB2 connection box with a 3 5 meters connecting cable DOCK MU USB2 Connection box with integrated image memory and USB2 digital output 2 5 metre cable to connect the handpiece to the connection box 5 metres and 7 metres optional e Installation manual This device was packaged in a custom carton This carton should be kept for possible transportation We provide a small quantity of compli
18. mentary dental barriers necessary for the intra oral use of the camera For more details about purchasing these products please refer to our catalogue or contact our commercial service 3 NOTE The device was designed and developed with its accessories in order to guarantee maximum performance and safety to you The use of different origin accessories can represent a risk for you your patients and your device 2010 03 26 User s manual Sopro 717First 3 ENGLISH SAFETY INSTRUCTIONS Do not expose the dental camera to liquid spray and do not store it in a humid environment electrocution risk When handling camera always take the appropriate hygiene measures and precautions in order to prevent cross contamination risks Infection control procedures must be observed when using accessories such as dental barriers in order to prevent cross contamination risk from one patient to another Install the dental camera in a clean dry and well ventilated place Disconnect the camera from the power supply if you are not going to use it for several days Do not pull on the cable Never compress or nip the handpiece cable Never expose the product to high vibrations Do not drop the camera n no way should this camera should be immersed in any liquid nor should it be autoclaved For each new patient it is essential to use the dental barriers provided with the camera or provided as a compliment Be
19. nsmitters a site measurement should be performed If a field level measured in the use environment of SOPRO device exceeds the compliance levels above applicable the good operation of SOPRO device should be checked If abnormal operations are proved some further measures should be taken such as reorientation or relocation of the standard device b Above the 150 kHz to 80 MHz frequency band the field level should be lower than 3 V m Recommended separation distances between the portable and mobile RF communication devices and SOPRO device in an electromagnetic environment in which t are checked The user of SOPRO device can help to avoid electromagnetic interference by maintaining a minimal distance between the portable and mobile RF communication devices transmitters and the recommended SOPRO device such as recommended below depending on the maximum output power of the communication device Rated maximal output Separation distance depending on the transmitter frequency m power of the 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz transmitterW d 1 6 P d 1 6 d 2 33 P 0 116 0 116 0 233 For the transmitters whose maximal output is not listed above the recommended separation distance d in metres m can be determined by using the equation applicable to the transmitter frequency where P is the maximal output of the transmitter in watts W rated by the transmitter manufacturer Note 1 At 80 MHz and at 800 MHz the separat
20. omagnetic environment Immunity trial Severity level level Guide Portable and mobile RF communication devices should not be used at a distance from SOPRO device including the cables lower than the recommended separation distance calculated with the applicable formulas depending on the emitter frequency Recommended separation distance d 1 16 P d 1 16 P 80 MHz to 800 MHz 2 33 800 MHz to 2 5 GHz here P is the maximum rated output of the transmitter in watts W by the transmitter manufacturer and d the recommended separation distance in metres m he field levels emitted by the fixed transmitters determined by an electromagnetic measurement of the site should be lower than the compliance level in leach frequency band Interference may occur in the vicinity of the devices bearing the following symbol Note 1 At 80 MHz and 800 MHz the higher frequency band applies Note 2 These recommendations may not apply in every situation Electromagnetic wave propagation i modified by the absorption and reflection due to the structures objects and persons 8 Sopro 717First User s manual 2010 03 26 ENGLISH e fixed transmitter field levels such as the base stations of the radio telephones cellular wireless and terrestrial mobile radios domestic radio AM FM and TV radio communication cannot be theoretically assessed precisely To obtain the electromagnetic environment due to the fixed RF tra
21. ontractual document Ref 011353 A Copyright 2010 SOPRO All rights reserved No information or part of this document may be reproduced or transmitted in any form without the prior permission of SOPRO
22. r Carefully close the packaging box x In case of contact with blood or important soiling it is strongly recommended to follow a disinfecting process First of all clean the handpiece with disinfecting wipes then roll up several disinfecting wipes around the handpiece and leave on for 15 minutes 18 Sopro 717First User s manual 2010 03 26 ENGLISH AFTER SALES SERVICE 10 1 WARRANTIES SOPRO ensures its products to be free from material and manufacturing defects for a period of one 1 year coming into force at the purchase date This warranty does not apply to misused modified untended or accidentally damaged products or products subject to abnormal use and handling conditions The distributors other than ACTEON Group s subsidiaries are not authorized to apply a warranty more extended on behalf of SOPRO The entire liability of SOPRO is limited to its convenience when replacing or repairing free of charge the defective product if it has been sent to SOPRO After Sales Service This applies for the warranty period Outside of France access to the warranty is only possible if the product was bought in one of the points of sale authorized by SOPRO in the country where it will be used THIS WARRANTY CONSTITUTES THE ONLY AND UNIQUE REMEDY IT REPLACES ANY OTHER WARRANTY FOR EXAMPLE A WARRANTY OF ADEQUACY TO A PARTICULAR AIM SHOULD IT BE EXPLICIT OR IMPLICIT SOPRO SHALL NOT BE LIABLE FOR AN
23. site one and a Y C S Video one One of these two outputs should be connected to the monitor video input preferably Y C S Video According to the connection box used this camera has a digital USB 2 0 output that can be connected to a computer USB2 port Except for the DOCK USB2 8 5 FOOTSWITCH The footswitch should be connected here Pur if you have selected it to freeze the image Except for the DOCK USB2 2010 03 26 User s manual Sopro 717First 15 ENGLISH 8 6 IDENTIFICATION The indications born on the boxes identify the dental camera according to the international standards 601 1 and 417 Video output Handpiece connection Footswitch connection IN Continuous voltage USB2 output aE IPSE BF type camera Caution please consult the ACCOMPANYING DOCUMENTS Disposal of electric and electronic equipment marketed after 13 August 2005 This symbol indicates that the product cannot be treated as domestic waste For medical devices this symbol is associated to the manufacturing year expressed with four digits For medical devices this symbol is associated to the manufacturer name and address c ii Product compliance according to the European directive 93 42 EEC relative to medical devices Grounding The devices that connect to video or USB outputs should comply with IEC 60950 standard 16 Sopro 717First User s manual 2010 03 26 ENGLISH
24. utput 2 0 e Controller dimensions L 145 W 130 35 mm e Controller weight 245 g DOCK MU USB2 Memory one and four images Power supply 24 V 50 Hz 60 Hz Consumption 10 VA 1 PAL or NTSC video output 1 PAL or NTSC S video output 1 digital USB output 2 0 e Controller dimensions L 100 W 72 36 mm Dock weight 190 g 22 Sopro 717First User s manual 2010 03 26 ENGLISH DOCK USB2 Cable length 3 5 m 1 digital USB output 2 0 Controller dimensions L 100 46 20 mm Dock weight 165 g BF type applied part Operating temperature 10 C to 40 C Storage temperature 20 C 45 C Relative humidity 10 to 90 Atmospheric pressure 900 hPa to 1 060 hPa Continuous service Not protected against water chutes Not adapted to the use in presence of an anaesthetic mixture flammable with air oxygen or dinitrogen monoxide Complies with the European directive 93 42 EEC Complies with EC60601 1 standard Complies with IEC60601 2 18 standard Complies with UL 60601 1 et CSA 60601 1 standard 2010 03 26 User s manual Sopro 717First 23 y T 0459 ACTEON Imaging ZAC Ath lialV Avenue des Gen vriers 13705 LA CIOTAT cedex FRANCE T l 33 0 442 98 01 01 Fax 33 0 442 71 76 90 E mail info sopro acteongroup com www sopro acteongroup com Non c
Download Pdf Manuals
Related Search
Related Contents
TNT-2988MPEG2 FRE IM Bijoux en béton Samsung P2250W Manuel de l'utilisateur User Manual Région - Journal de la Région Alsace RVDF - AdMan - ENG.qxd:_ Copyright © All rights reserved.
Failed to retrieve file