Home
EHS Series User Manual
Contents
1. the good at this time When display tAr O tarring automatically If the weighing is not stabilized display shows until stable then tarring automatically and the display shows zero the tare indication light be on c Clearance of tare weight In the Tare light ON state press Tare Zero key Tare weight is cleared and it displays gross weight the tare indication light be off PROVIDER OF LIFESTYLE amp INDUSTRIAL SCALES P O Box 40646 Plot No 613 1124 Ras Al Khor Industrial Area II Aweer Dubai U A E Tel 971 4 3337789 90 Fax 971 4 3336210 E mail info accuratemeezan com ACCURATE MEEZAN TRADING L L C Cagle www accuratemeezan com SINCE 3 159 71 8 SCALE UPSCALE PROVED APPROVED Sleeping mode When the weight is stable for zero about one minute the crane scale will auto enter the sleeping mode the display will be continuous light for segment of LED Help to save the energy When press the key or load weight the scale will auto exit the sleeping mode and return to general weighing state III Calibration and parameter setting 1 2 3 4 6 8 Enter calibration state under general weighing state press A C key about 3 seconds to enter calibration state if the calibration parameter is wrong will directly jump to step 3 Display CAL press A C key to enter weight calibration press Accu key to jump to setp 8 to set the parameter at this time pr
2. ACCURATE MEEZAN TRADING L L C Eagle www accuratemeezan com SINCE 1918 SCALE UPSCALE PROVED APPROVED Crane Scale EHS Series OPERATION MANUAL PROVIDER OF LIFESTYLE amp INDUSTRIAL SCALES P O Box 40646 Plot No 613 1124 Ras Al Khor Industrial Area II Aweer Dubai U A E Tel 971 4 3337789 90 Fax 971 4 3336210 E mail info accuratemeezan com WW ACCURATE MEEZAN TRADING L L C Cagle w accuratemeezan com SINCE 1918 SCALE UPSCALE PROVED APPROVED I Main Specification 1 5 digits LED display anti shaking and anti vibrating swing intellectual digital filter stabilizes reading with a stabilization time of less than 5 sec Adoption of low power consumption design extends service life of the battery Auto sleeping function With full charged battery LED display can continuously work for 100 hours It also has over discharge protection circuit which prevents battery from damage and shortening of service life due to over discharge It can automatically save energy and extends service life of battery With many parameter to be selected with wireless control simple operation functions of instant tarring delayed tarring suitable for operation in different place Safe over load 150 F S Damaging over load 200 F S Working environment 10 C 40 C 85 RH II Operation mode 1 2 Key function a Hold On Off press this key for about 3 seconds to power on off the scale Under g
3. cu key D key equal to A C key Note the controller can not power on the scale V Auto off function 1 When the crane scale be in state of sleeping for one hour it will be auto power off 2 When the power of the battery is not enough and the weight be zero it will display LB to clue the user to recharge the battery if the power is seriously not enough after LB flash for times the crane scale will auto off VI Cautions Make sure that the hoist is hung at the arc center of the electronic crane scale and the good is also hung at the center of the hoist Serious impact to the scale body is not allowed If not in use please keep the scale at a dry cool and ventilated place Please check regularly to see if there is any loose or missing screw Switch the scale on after being sure there is no problem Meet lightning in open air please switch off the scale temporarily In order to ensure the safety of the scale structure please push the good directly if it is needed to change the direction or position of the good when weighing Do not push the scale body directly Please do not excess the load range of the scale of hang good for a long time otherwise it will cause fatigue of the load cell and reduce the lifespan of the scale VII Shooting of simple troubles if can not power on or off the scale naturally please insert a small pin to the hole on the right down side of the overlay for 2 seconds a
4. eneral weighing state press this key to keep the present weight display the weight will not change and blink display at this time press other key is nullity press this key again to release the keeping state When calibrate and display the accumulated data the Hold key is nullity b Tare Zero press this key to tare or zero when calibrate and set the parameter this key can act as exit key under tare state the tare indication light will be on c Accu Under the state of accumulating the weight when the weight be zero press this key and do not release to check the accumulated information when calibrate the parameter it can act as select key Under state of accumulate the ACCU indication light will be on d A C press this key to clear the accumulated information when calibrate the parameter it can act as confirm key Zero and Tare operation a Instant tare Hanging the goods after the weighing is stable press Tare Zero key if the weight is less than the zero range set by user the function will be zero display zero and the tare indication light will be off if the weight is more than the tare start weight set by user the function will be tare display tare and the tare indication light be on b 9 seconds delayed automatic tarring press Tare Zero key and do not release 3 seconds late it will display tAr 9 release the key the display value reduces at a speed of minus 1 per second and shows tAr x Hang
5. ess Tare Zero key to exit calibration and back to weighing state Display dotzx means to select the decimal point press Accu key to transfer the selection the selectable decimal point will be O 1 2 press A C key to confirm enter the next step Display xxxxx means to set the full capacity the highest bit will start flash press Accu key to change the number of this bit press A C key to confirm and set the next number finish the setting of 5 number and enter the next step Display CAL 0 means to zero calibration After making sure empty scale and stable weighing press A C the display shows At the same time two indication light will flash means to catch the zero Display xxxxx one number is falshing means to set the calibration point weight the acquiesce is full scale calibration press A C and Accu key to set each number press A C to confirm Display and two indication light is flashing means wait the stable of the loading at this time please load the entered weight after the loading is stable the weight calibration is finished keep the weight parameter if the system parameter is wrong directly jump to step 9 Display SET P press A C key to enter parameter setting press Accu key to jump to step 2 for weight calibrate at this time press Tare Zero key to exit the calibration and exit to weighing state Display d x means to set the division p
6. nd press the power on key to reset the system If the battery can not be charged please check the charger or the battery if the charge is good after the battery finish charging the battery volt should be over 6 3V if the volt is below 5 8V it will need to change the battery PROVIDER OF LIFESTYLE amp INDUSTRIAL SCALES P O Box 40646 Plot No 613 1124 Ras Al Khor Industrial Area II Aweer Dubai U A E Tel 971 4 3337789 90 Fax 971 4 3336210 E mail info accuratemeezan com
7. ress Accu key to select the division there are 6 division for select 1 2 5 10 20 50 press A C key to confirm the select and enter next step Display JZ Xd means to set the zero tracing range to x times division press Accu key to transfer the selection 1d 2d 3d 4d 5d 6d 7d press A C key to confirm and enter the next step PROVIDER OF LIFESTYLE amp INDUSTRIAL SCALES P O Box 40646 Plot No 613 1124 Ras Al Khor Industrial Area II Aweer Dubai U A E Tel 971 4 3337789 90 Fax 971 4 3336210 E mail info accuratemeezan com ACCURATE MEEZAN TRADING L L C Cagle www accuratemeezan com SINCE 1918 SCALE UPSCALE PROVED APPROVED 11 Display TZ X means the set zero range be x the tare start weight press Accu key to select from 2 4 10 20 50 press A C key to confirm and enter the next step 12 Display SPd x means to set the display speed press Accu key to select there are three mode can be select from low to high 1 2 3 press A C key to confirm the parameter setting finished and keep the setting Note During calibrate press Tare Zero key to be back to last step or exit the calibration if exit before the last step then all the parameter will not change only when finish the step 7 or 12 the parameter will update and keep the change IV Wireless control key A key equal to Hold On Off key B key equal to Tare Zero key C key equal to Ac
Download Pdf Manuals
Related Search
Related Contents
DETERMINACiÓN DE LA EDAD DE SafeZone Scanner with a Configurable Safety Relay Web Submission - Staples Copy & Print R BETRIEBSANLEITUNG SINUS N - Santerno SERVICE MANUAL Electric wheelchair Harbor Freight Tools 1/2 in. Air Impact Wrench With Extended Anvil Product manual Samsung HT-TX725G Benutzerhandbuch Gas grill rotisserie Rożen gazowy Asador giratorio para Daikin ATXV50AB air conditioner Copyright © All rights reserved.