1. The controller display changes to the last card read while pressing this button in STANDARD MODE The controller will respond with 3 beeps immediately After releasing buttons S1 and S2 the controller display will light up displaying H 0 8 This indicates that the controller is in Master Tag learn mode and that the first tag to be presented to the reader head will become the new Master Tag The controller will respond with 3 beeps This indicates that it has learned the new Master Tag and exited Master Tag learning mode The controller is now ready for standard operation USER TAG PROGRAMMING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Teaching the controller a new USER TAG Present the Master Tag to the reader and keep it in the reader field Remove the Master Tag and present the new User Tag s to be learned one at a time to the reader After teaching the controller the new User Tag s present the Master Tag to the reader again to exit User Tag learn mode The controller responds with a single beep After a few seconds the controller responds with an additional 3 beeps indicating that it has entered User Tag learn mode H E 1 second after presenting a new User Tag the controller will respond with a single beep This indicates that the controller has learned the new User Tag Note Should the controller respond with 3 beeps instead it is indic
2. SOFTWARE Users 1000 max Code Size 64 bits Read Time lt 2 seconds SPECIAL FEATURES e Auto frequency tracking e Door sensor input e Auto exiting software e Auxiliary free exit timing as per e Master tag learn mode relay output time e Master tag voiding e Fire alarm input e Individual tag voiding e Programmable relay output time e Entire memory voiding 150ms 9 seconds e Last tag read display e Two reader head capability
3. a Single Door Access Control System E USER MANUAL DORTAG VI MIC 0302115 October 2005 Revision 01 INSTALLATION INSTRUCTIONS THE READER HEAD S The reader head comes pre wired with a 2m cable connected to it If the cable is to be replaced with a longer cable please note the following restriction Maximum cable lengths 5 meters unshielded cable 15 meters shielded cable Wiring from the reader is as follows BLUE Buzzer BUZ RED Supply 5V BLACK Ground 0V YELLOW Loop GREEN Loop Two screws and two wall plugs are supplied with the reader head for mounting onto a wall The following steps should be followed INSTALLING THE READER HEAD 1 Use the READER HEAD to mark off the holes to be drilled on the wall where the reader is to be mounted Note The holes should only be deep enough to accept the wall plugs 2 Once the holes have been drilled insert wall plugs 3 Mount the reader head and fasten the screws making sure that the cable is run correctly 4 Place reader head sticker onto the reader head and align the reader head sticker LED hole with the LED on the reader head Installing two reader heads It is possible to install two reader heads on this system Please note that this is a single door system and there is only one output relay The two heads will therefore be fitted to the ENTRY and EXIT points on a single door 6 The two reader heads will be wired in parallel in the controller as p
4. ating that the 1000 user limit has been exceeded and that the controller has exited User Tag learn mode The controller responds with 3 beeps indicating that it has left User Tag learn mode Note Should the user forget to exit User Tag learn mode the unit will automatically exit this mode after 30 seconds Note After completing this procedure present each tag to the reader press button S1 on the controller to display the tag number and record this number against the name of the user in a register Repeat this exercise for all the new tags entered into the system Note Should an invalid card or tag be presented to the reader the unit will NOT respond with a beep and no user number will appear on the controller USER TAG VOIDING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE USER TAG VOIDING Present the Master Tag to the reader and keep it in the reader field Press button S2 Press button S2 to scroll to the User Tag number that has to be voided from the system Note By holding button S2 in the scrolling speed will increase To void a User Tag from the system PRESS S1 button 5 To exit User Tag Voiding Mode leave the controller for 30 seconds The controller responds with a single beep After a few seconds the controller responds with an additional 3 beeps indicating that it has entered User Tag learn mode The controller responds with 3 be
5. ed time setting is achieved 3 Leave the unit for 30 seconds to exit this MODE or press S1 Unit responds with 3 Beeps and BBE The display increments up to Hod 2 seconds up to Tinia 9 seconds Tiaia This is a special setting for a 150mS PULSE OUTPUT The unit responds with 3 Beeps and enters STANDARD MODE LAST TAG READ INSTRUCTION Looking for the LAST TAG READ 1 In STANDARD MODE press and hold S2 2 Release button S2 The number of the last tag read will be displayed TECHNICAL SPECIFICATIONS HARDWARE Operating Voltage Average Current Consumption Maximum Current Consumption Relay Output Rating Operating Frequency Read range Reader heads Read head feeder cable length Cable Mechanical dimensions Environmental Rating Mass Operating temperature Indications 12V AC DC 33mA 1 Reading Head 55mA 12V 24V 5A Change over contacts 125kHz 50Hz 4kHz modulation 6cm 10cm Dependant on tag type 1or2 2m Standard 5m max if unshielded 15m max if shielded 5 Core Controller 104mm L x 94mm W x 25mm D Reader head 75mm L x 39mm W x 15mm D Controller IP00 Reader head IP54 Controller 70g Reader head 70g 10 C to 60 C Visual Bi Colour LED Audible Buzzer The unit communicates with signals between 50Hz and 4kHz and should thus be installed away from any such signals
6. eps and after S2 is released HO is displayed This indicates that the controller has entered User Tag Voiding mode The number displayed on the display is the number of the User Tag that will be voided from the system when button S1 is pressed When voiding a User Tag the controller responds with a single beep and the display changes to HOG Note 1 The display shows the memory location acted on rather than whether there is a code or not If H OD is displayed that location has been voided If the display is incremented to that memory location again the location number will be displayed again Note 2 The Master Tag memory location can not be assessed unless the whole memory is voided See Master Tag PROGRAMMING INSTRUCTIONS The unit responds with 3 beeps and enters STANDARD MODE RELAY OUTPUT TIME PROGRAMMING INSTRUCTION PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Adjusting the door lock mechanism RELAY OUTPUT TIME This function is used to set the time for which the relay will provide an output to the door latch in the event of a card tag being introduced or the push and release of the free exit RTE push button The default time setting is t1 1 second Note When re setting the relay output time the door alarm settings will need to be reset at the same time 1 Press S2 and release 2 Continue pressing S2 to increment the timer until the requir
7. er the instructions overleaf 7 Jumper LOOP SELECT must be OPEN if one reader head is installed e Jumper LOOP SELECT must be FITTED if two reader heads are installed e e INSTALLING THE CONTROLLER Power AC DC 12V AC DC AC DC 12V AC DC Reader 5V Red from reader head OV Black from reader head Buzzer Blue from reader head Loop Yellow wire from reader head Loop Green wire from reader head Aux 0V Bridge between RTE or Fire RTE Request to exit input Fire Fire alarm input Normally open Relay N O Normally open relay contact Common Common relay contact N C Normally closed relay contact Warning Failure to follow the wiring instructions may result in permanent damage to the controller Single Door Access Control System Wiring Details O we common Magnetic Lock Fire alarm input Request to exit 4 Green Push to make contact RTE a ewe ik res 12v AC DC Power Supply 1 Amp lt Strike Lock Notes Jumper LOOP SELECT must be fitted for two reader head applications lis Normally open fire alarm contact opens door in the event of a fire Fire alarm input The fire alarm input is a facility whereby a fire alarm device such as an emergency glass break switch or fire alarm panel can close the circuit to open all doors immediately Please note the fire alarm input is non latch
8. ing and Fail safe locks should be used with this function PROGRAMMING INSTRUCTIONS Note The DorTag VI employs AUTO EXITING software for security reasons In any of the programming modes the controller will automatically revert back to standard operating mode if the user takes no action within 30 seconds Three different operating modes exist as indicated by the display dot position POSITION 1 z z z Standard operating mode POSITION 2 z z e z User tag Learn mode POSITION 3 H z z Voiding mode Master Tag Learn Mode POSITION 4 H z z g The USER ACTION indicates the steps the user must take to accomplish a certain PROGRAMMING FUNCTION The CONTROLLER RESPONSE indicates the response that the controller will have to a USER ACTION IT IS RECOMMENDED THAT THE USER READ THE USER ACTIONS AND CONTROLLER RESPONSES CAREFULLY BEFORE ATTEMPTING TO PROGRAM THE CONTROLLER MASTER TAG PROGRAMMING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Teaching the controller a new MASTER TAG PRESS amp HOLD button S1 The top button Note Teaching a new Master Tag can only be done in STANDARD MODE Warning On presenting a NEW MASTER TAG the entire memory will be voided and all user tags will have to be reprogrammed While still holding button S1 press button S2 The bottom button 3 Present the new tag to the reader This tag will become the new Master Tag