1. Traceable Tie Timer Instructions SPECIFICATIONS Display high 6 digit LCD Range 24 hours to 1 second Resolution 1 second Accuracy 0 01 Alarm Audible Size 1 x 2 7116 Weight Less than 1 oz Features Clock Countdown Countup Stopwatch Memory CONTROLS INDICATORS Clock Sets time of day Count Up Stopwatch mode Timer Countdown from preset time HR Advances hour setting when in the clock mode MIN Advances minute setting when in the clock mode SEC Advances second setting when in the clock mode CLEAR Clears all time values memory settings and returns the display to zero MEMORY Sets time value for recall START STOP Starts and stops timing function in countup and timer modes Clear Memory Start Stop Clock Count Up Timer Battery Tie Clasp Compartment Panel OPERATION TIMING MODES The red switch located on the bottom of the unit will switch the timing between Clock Countup stopwatch and Timer mode SETTING TIME OF DAY 1 Slide the red switch to CLOCK position 2 Press and hold the CLEAR button for 3 seconds to toggle the display between 12 hour and 24 hour format 3 Press the HR MIN or SEC button to advance display to the desired time Press and hold the button for rapid advancement COUNT UP Slide CLOCK COUNT UP TIMER switch to COUNT UP position Press START to start counting up To temporarily st
2. alibration Laboratory by A2LA Traceable is a registered trademark of Control Company 2007 Control Company 92 5043 00r2 122707
3. n memory button is depressed 3 Press START Timer will start count ing down When the set time limit is reached the Alarm will sound the Time s Up indicator will flash and Timer will count up from 0 00 00 to indicate elapsed time since the alarm sounded 4 Press START STOP to stop count up 5 Press MEMORY to recall preset time 6 Press CLEAR to cancel preset time or press START STOP to begin countdown again ALL OPERATIONAL DIFFICULTIES If this unit does not function properly for any reason replace the battery with a new high quality battery see Battery Replacement section Low battery power can occasionally cause any number of apparent operational difficulties Replacing the battery with a new fresh battery will solve most difficulties BATTERY REPLACEMENT Erratic readings a faint display no display or a flashing display are all indicators that the battery must be replaced Slide the battery compartment panel located at the back of unit in the direction indicated Replace exhausted battery with a new battery and secure the battery compartment panel Replacement battery Cat No 1039 WARRANTY SERVICE OR RECALIBRATION For warranty service or recalibration contact CONTROL COMPANY 4455 Rex Road Friendswood Texas 7 546 USA Ph 281 482 1714 Fax 281 482 9448 E mail sales control3 com www control3 com Control Company is ISO 9001 Quality Certified by DNV and ISO 17025 accredited as a C
4. op timing press STOP Press START to restart If Count up is already counting press START STOP to stop count up Press CLEAR to reset digits to 0 00 00 oar wnr gt SETTING TIMER 1 Slide the CLOCK COUNT UP TIMER switch to TIMER 2 If Timer is already running press START STOP to stop and then CLEAR to clear entry 3 Press and hold each of the HR MIN or SEC buttons to set the desired time 4 Press START Timer will start counting down When the set time limit is reached the Alarm will sound the Time s Up indicator will flash and Timer will count up from 0 00 00 to indicate elapsed time since the alarm sounded The TIMER indicator will flash while in Clock or Count up mode to indicate the Timer is running 5 To completely or temporarily stop timing cycle press STOP To restart press START 6 To clear entry press CLEAR If Timer is running press STOP first 7 When in Clock mode or Count up mode stop the alarm by pressing STOP 8 To stop the alarm and stop and clear the TIME S UP count up select Timer mode and press STOP MEMORY 1 Select Timer mode Press memory to see if an entry is already stored in MEMORY press CLEAR to return display to 0 00 00 2 Ifthe timer is running press START STOP to stop Depress each of the HR MIN or SEC buttons to set the desired time and press MEMORY to enter the preset time The MEMORY indicator will only show on the display in Timer mode whe
Download Pdf Manuals
Related Search
Related Contents
【 ケンベアーBB インターネット接続 取扱説明書 】 備 品 に つ き 持 ち 出 DIE ZEIT 10/2011 - ElectronicsAndBooks Installation and operating instructions Automatic Control LAB. EngM513 Laboratory User`s manual Version I Symantec Norton Internet Security 2003 (10024885) for PC Flanging/Start Up Kit - GE Healthcare Life Sciences Hamilton Beach 44601 User's Manual MVH-350BT MVH-150UI GPS 搭載液晶表示 ソーラーレーダー 取扱説明書/保証書 目 次 Copyright © All rights reserved.
Failed to retrieve file