1.                                                                                                                                               8 99 Drive Depth without Optional Switches  745          Drive Depth with Optional Switches        i i  S  DOS    10 85  275  11 65  295     Y     8 25    210    9 15 4  232    Drive Is Shown with Optional Power On Off Switch  Forward Stop Reverse Switch  and Main Speed Potentiometer     RECONDITIONING THE BUS CAPACITORS   It is recommended that the bus capacitors be reconditioned if this product has been  in storage for over one year  To recondition the capacitors  apply the AC line  with  the drive in the Stop Mode  for a minimum of one hour     TERMINAL BLOCKS     1               WIRING INSTRUCTIONS   Power Connections        3 WARNING  Read Safety FIGURE 2A   PKG  A and PKG  C     Warming  ch page     before TERMINAL BLOCK TM1 LAYOUT          using this drive  Disconnect the main power L1 L nmn Te    when making connections to the drive  OTIO    For Terminal Block TM1 wiring                   information  see Table 4 on       page 17  FIGURE 2B   PKG  B TERMINAL BLOCK  TM1 LAYOUT   IMPORTANT   APPLICATION NOTES       12 L3N  P T2 B    1  To Avoid False Tripping         ela      Do not bundle motor wires   from multiple drives in the   same conduit  Do FIGURE 2C   PKG  Ci TERMINAL BLOCKS  not bundle the AC TM1 and TM3 LAYOUT   line with motor  wires   Note  AC  power to multiple  drives can be run in  the same conduit    Be sure at l
2.                                              425      108    e    18  6     gt   D                 Q                     6 77  Drive Depth is ETE    MOUNTING INSTRUCTIONS   It is recommended that the drive be mounted vertically on a flat surface with ade   quate ventilation  Leave enough room below the drive to allow for AC line  motor  connections  and any other wiring  Care should be taken to avoid extreme haz   ardous locations where physical damage can occur  When mounting the drive in an  enclosure  the enclosure must be large enough to allow for proper heat dissipation  so that the ambient temperature does not exceed 50   C  See Figures 1A  1B  1C   and 1D  on pages 12   15     Note  NEMA 4  IP 65 models are for indoor use only  They are not for use in  explosion proof applications     CAUTION  To avoid overheating  do not mount the optional brake resistor under  the drive     18             Sec  Il   Mounting Inst   Cont         FIGURE 1C     MECHANICAL SPECIFICATIONS  Inches mm   for Models KBE2 1125 4  1150 4  1101 4  2101 4  Pkg  C                                                                                6 69    Drive Depth is          Sec  11   Mounting Inst   Cont      FIGURE 1D   MECHANICAL SPECIFICATIONS  Inches mm   for Models KBE2 2202 4  2203 4  4301 4  4302 4  4303 4  Pkg  C1                                                                                                                                                                                     
3.                           aur  JV  Un uel        2   09 06        SHOA                1nduj aur                                        7 6020  0487     ON                                       payey             10    Sec        Introduction  Cont         TABLE 2   GENERAL PERFORMANCE SPECIFICATIONS                                                                               Factory  Description Parameter   Range Setting  AC Line Input Voltage  VAC  icm em       Input Line Frequency Range  Hz  48   62      Output Waveform Sine Coded PWM     Frequency Range  Hz  0 1   200 60  Switching Frequency Range  kHz  4 16 8  Frequency Resolution  Hz Increments  10      aoe  Hz     Acceleration Deceleration Range  Seconds  0 1   999 5 0  Overvoltage Trip Point   230 VAC    460 VAC  VAC  290  580      Undervoltage Trip Point   230           460                 140  280    Overload Rating    for 1 Minute  150      Minimum Frequency Range  Hz  0 0   200 0 0  Maximum Frequency Range  Hz  1 0   200 60 0  Braking Torque without Braking Resistor      20 20  Braking Torque with Braking Resistor      20   1304 20  Operating Temperature Range    C   10 to 50      Humidity  Relative  Non Condensing   96  0 95      Maximum Vibration  G  1      Output Relay Contact Rating 1    at DC       External Analog Signal Input 0  AR 0   10 VDC  Remote Speed Potentiometer  Q  5k or 10k      Analog Output Voltage  Volts        0 10           Built In EMC Filter Sp    ecification     F    Suffix Models        Cla
4.                         16  IV  Terminal Block TM1 Wiring Instructions  Power Connections                16  V  Terminal Block TM2 Wiring Instructions  Signal Connections                19  A  External Start Stop Forward Reverse Connection                      20  B  External Frequency                                                  20  C  Multifunction Output Relay Connection                              24  D  Analog Output Voltage Connection                                  24      SAGENS FUSING                  br ice bd            TU ord Tb e tod aU 24        Recommended High Voltage Dielectric Withstand Testing  Hi Pot            26  MIL  Drive  Operation          na ee et Ree      26  A  Digital Keypad Description                                      26  B  Digital Keypad Operation                                        28  C 3Programmirng     333 igni                                 UAE Er  30  D  Programmable Functions  Summary List                             36  IX  Programmable Functions  Detailed                                   39  X Optina Accessoris coe es ese ew ERE Y P ODE               51          limited  Warranty    sc mt tton e So sb        dU          56  Tables  1    iBlectricaliRalings   s e xu      SERE ARR dels 9  10  2  General Performance Specifications                                  11  3  Model Number Identification  2 004                                           12  4  Terminal Blocks TM1               Wiring Information                   
5.                    14                                    3010 21u0129 3 814   Sy 08 002 00               sng                      uonoefu              Jaquinn            Jaquinn           Moped   po9     uey                101101959 uoyoun4 uonoung                                   15 AYYNNNS SNOLLONNA 3 18VIAWVHOOHd   91 318  1    38          PROGRAMMABLE FUNCTIONS  Detailed   The KBE2 Series drive contains programmable functions which are described  below  See Section VIII A  on page 26  for keypad instructions  See Table 15  on  pages 37 and 38     F01   Acceleration Time       Factory Setting     5 00     5 0 Seconds      F01 is used to set the acceleration time   FO1 is factory set to    05 0    for 5 second acceleration  The acceleration time is  based on the time it takes for the drive output to reach 60 Hz     If the Set Frequency is greater than 60 Hz  the acceleration time will be proportion   ally increased  If the drive is set to less than 60 Hz  the acceleration time will be  proportionally decreased     When accelerating high inertial loads  the acceleration time may be extended and  the current limit circuit may activate due to the Stall Prevention Circuitry     Programmable Range  0 1   999 Seconds    F02   Deceleration Time       Factory Setting     5 00     5 0 Seconds          2 is used to set the deceleration time   202 is factory set to    05 0    for 5 second deceleration  The deceleration time is  based on the time it takes for the drive output to reach
6.                 Drive Mounted on RFI Filter    RFI Filter    AC Line  Input             Internal  Connection           RFI Filter Mounted on Metal Frame Motor Mounted on Metal Frame     Cable shield should be grounded on drive side only     C  Remote Speed Potentiometer Kit  Part No  9831    Provides remote mount   ing of the speed potentiometer to control motor speed  Kit includes a linear 5kQ    5 Watt wire wound potentiometer  mounting hardware  and panel insulator     D  Brake Resistor     Provides rapid stopping with high inertial loads  See Table  20  This option is only available for Models KBE2 2202  2203  4301  4302   and 4303     TABLE 20   BRAKE RESISTOR SELECTION CHART                            3 Braking Brake Resistor  pave                   Dimensions  W x H x L   Model No     HP   kW       PartNo       w      Inches mm   KBE2 2202 2   1 5  120 14180 100 150 1 57 x 0 79 x 8 46 40 x 20 x 215  KBE2 2203 3   2 2  115 14190 70 200 2 36 x 1 18 x 6 49 60x 30 x 165  KBE2 4301 1   0 75  125 14230 750 60 1 57 x 0 79 x 4 53 40 x 20x 115  KBE2 4302 2   1 5  120 14240 400 150 1 57 x 0 79 x 8 46 40 x 20 x 215  KBE2 4303 3   2 2  130 14250 250 200 2 36 x 1 18 x 6 49 60x 30 x 165                                     ncludes all   P  and   4  suffix models   52    Sec         Optional Accessories  Cont             DownLoad Module     DLM   Part No  14145      Uploads and downloads drive  programs  Requires KBE2 to DLM Communication Cable  Part No  14147    See Figure 20     FIG
7.                cq              paje1                        ue        eoejday 2916 00           jeruau         7  UoneJojo2op                          1ndui      Oy 34  1981105                             1ndui      oY 10 paads jos      abeyonsang    0  0                      euin                        ay  952912          00  195 SI AWW UOIeJaja2aq  uonesipu              341284102 asneg                                    fejdsiq                                SNOLLOV 3ALLO3HHOO ANY 63000 NINYI   21 318vL    50       TABLE 18     STATUS INDICATORS WHEN THE DRIVE IS IN  EXTERNAL START STOP MODE  F10   001                    Display a  Indication   Description  spo The drive has been set to Zero Frequency using the keypad or external frequency  command   The drive is in Stop Mode due to an interruption and resumption of the AC power   SP1 To restart the drive  open and close the Start Stop contact   Note  F28 is set to    001     Disable Automatic AC Line Start   factory setting    SP2 The RUN STOP key is pressed while the drive is in the Run Mode              F29     CPU Program Version  Factory Setting  Current Software Version     229 is used to display the software  version of the drive        F30   Logs Last 3 Faults that Occurred    F30 logs the last three faults that occurred  in chronological order  Press the key  to scroll through the three faults that occurred  The decimal point in the display  indicates the chronological occurrence of the fault     x xx    indicates 
8.               pedA  y   000   114    pajogjas 51                  paads 195914  Dunes AouenbeJj              0  1453      10 V esf 10 100   114                 13539    10 W            55814  5 0           100             224     1  010 0              000  01 704   9 100   p04            00  lt 203                 pay90  UOR2011p      901  74000  01 224             7100   224 ueuw                                        0  jduieny            ayy 19891 01    uonelado 95892   E  Ael 3638           IM          aug                                                 0015 0145809 44  198109                  Ue sn 10 A9 13                               si              4015      91  9 ay  UIYM     sdo s 1010        Jaye              Y  19591 0  453  USEI      Aejdsip au    4045 pue                             4   yoe U09  euJejxe ue asn 10 Ady 1ISJY A      55814                                  Indu                       3y  S picky 83                            si              4015 jeuje1xe      Udy    eJnjejaduia  jueiquie 99npai 0                     9AoJduJ  uiu 00  s                        quaiquiy     paads 195 1e                                                                                                        ue uy eoejday    Bunel                         JUNI peo                                                ue ui aoejdey    Dunes                   paads 195 ye                   E                yndur           aui 1981109 ALIP 1981109U  10 MOJ 00  5               aui  2v  
9.              Function    de       Number Function Description Code Value Description of Code Value  223 Auto Restart After    Fault 000 Enable Auto Restart After a  Has Cleared  Factory Setting  Fault Has Cleared  Number of Auto Restart 005     224 Attempts  Factory Setting is  000   Five Auto Restart attempts  F28   Automatic AC Line Start oon Disable Automatic AC Line Start   Factory Setting                 33    Sec  VIII     Drive Operation  Cont             Automatic Restart for All Faults Including AC Power Loss    If the  application requires that the drive automatically restart after a fault has  cleared  including an AC power loss  Function F28 must be set as fol   lows  See Table 14     To change the setting of F28 from  001  to  000     1  The drive must be in Stop Mode  press the RUN STOP key    2  Press the DSP FUN key to display function number    3  Press the    or W RESET key until  F28  is displayed    4      Press the DATA ENT key  The function code will be displayed   Factory setting is    O01     Disable Automatic AC Line Start      Press the A or W RESET key until code  000  is displayed     6  Press DSP FUN key to return to the frequency display or press the  A or W RESET key to change to another function number            Note  For Automatic Restart  Function F10 must be set to     001     External Contacts  and a jumper must be installed  between Terminals 3 and 5 of Terminal Block TM2     TABLE 14     FUNCTIONS F23  F24  F28 SET FOR AUTOMATIC RESTART 
10.          au  49949  Duipeo  juarsuei                   Ajejeridogdde ue uy aoejday    Bunea          5                      10704      60   Dunes            2   5  0                                            2   540   290027                         Duunp jua11naJ8AQ  V20      104  Buras aum uomeJo a22e aui                      00  Bunjas auum                                     10           ayy               8A 994  p S               JO SISUEJ                                        SEH      EJOS SOJIM 1010                                         oj jua uno                dnueis                   aug   520     yojow              punoJ8 0j oseud 10 aseyd oj aseyd                                       payed                        ue uy aoejday                    spaaoxe peo                  IAU    210      60   Dunes            ZH SYOA                                         ZH SHOA 1291020  1010                                     ue uy eoe day                                     peo      604      195            2   540                                           ZH SHO A 1990090                 1030     110      814  Dumes kI      9508100         00  195 51 UOI29 0Jd                           2049913     wedau 10           ayy uunjag                   si                uonoejeg  epoui dojs     1               eju                90     edad 10           ayy uunjag  eN129Jap S                 uonoejeg            dojs ui si               ajuw  duiguaAQ HO                        ju
11.       C  Programming   All drive functions have been factory programmed  as shown in  Table 15  on pages 37 and 38     Application Notes  1  The KBE2 drive has been factory programmed for 60 Hz  motors for use in constant torque applications  FO5 is factory set to  004   60  Hz Constant Torque   To convert to 50 Hz motors used on general purpose  applications  set   05 to  001   50 Hz Constant Torque   as shown in Table 11   Also see Section IX  on page 39  for details on programming Function     5  olts Hz Pattern   2  To reset to factory settings use F25  as described       Section IX  on page 48     TABLE 11   REPROGRAMMING THE DRIVE FOR 50 Hz MOTOR OPERATION          Function Factory Code Setting New Code Setting  to Change for 60 Hz Motors for for 50 Hz Motors for  Motor Frequency Constant Torque Applications Constant Torque Applications  F05 004 001                   1  F18  Motor Overload Protection  I t     Motor Overload Protection is used  to set the maximum motor current as a percent of the full load rating of the    Sec           Drive Operation  Cont         drive  as described in Section IX  on page 45  F18 is factory set to    100      100  Full Load Rating of the Drive      Note  It is highly recommended that this function be programmed     a  The drive must be in stop mode  press the RUN STOP key   The set  frequency will flash on the display     b  Press the DSP FUN key to display function number       Press the    or W RESET key until    F18    is displayed
12.       INSTALLATION AND OPERATION MANUAL    KBE2 DIGITAL AC  ADJUSTABLE SPEED DRIVES    for use with 1 4   3 HP 3 Phase Induction Motors  115  208 230 or 380   460 Volts  50 60 Hz  1  amp  3 Phase AC Line Input        GENESIS           KBE2 2101 P    P N 11040  230VAC Input     1HP  0 75 kW     N10980    LISTED 16KJ             GS          cod    177007  RUN DSP    STOP   Gan  ISO  9002       Note  This drive has  been programmed  to operate 60 Hz  motors  For 50 Hz  0009909990900  motor operation   see Section VIII C  and Table 11 on  page 30                                   This Manual Covers    Panel Mount IP 20  KBE2 1125 P  1150 P  1101 P  2125 P  2150 P  2101 P  2202 P  2203 P  4301 P  4302 P  4303 P    NEMA 4  IP 65        2 1125 4  1150 4  1101 4  2101 4  2202 4  2203 4  4301 4  4302 4  4303 4       4 A See Safety Warning on page 6                    The information contained in this manual is intended to be accurate  However  the  manufacturer retains the right to make changes in design which may not be included herein     Automation and Control     2003 KB Electronics  Inc    See back cover           TABLE OF CONTENTS          Section Page  i  Simplified    Instructions az q     omes qub ba Icd hEGU OG CTRde REG ST RIEN 5  li               Warming       dcc bad ve x de ease          S RR ROUES PL 6      PUOOUCUON                    6           Mounting  INStFUCTIONS                   a    ee ee bec    eit o m Dec 13  Ill  Reconditioning the Bus Capacitors           
13.       s               1ndjno                ay                HOA 611104    abeyor indu            ay                 s   eDejjoA 14400                                    HOA 09  pue 062 104     V L0LC C383       V LOLL 389       V 06LL 2385       99    V ScLL 0389     0  y c383       9v     e0  v c383       9       LO  v c385       0 91  025     2020  2487       01L 0 6L     6006  2487   1012  2387        0912 2387        6016 63           10  2387          4 05 11 381        aseug sduy SNY   juan  peo  11400  Snonuimuo                                        suon                                            ov                             eur  JV                           2H 09 06   2 SHOA                         aur  JY                  SONILVY 1VOIHLIO3 3                                 3 9211 2387     ON                                       parey               Introduction  Cont                     2                                     34           nop oj            5  eDejjoA 1ndjno                ay                     611104                        auly 2   94                  si eDejjoA 14410                       Sjepoul OA 09  PUL 062 104        49    b    0   b 24 ay       9v    V c0  v c383       94       10                   091 072       2022  0487        aseug sduy SNY            peo  11400                                               9v son                   yndyng                                                  TVOIHIO3T3     318  1          01L 0 6L     ov   
14.      17  5  Terminal Block TM2 Wiring Information                               19  6  External Start Stop Control Using Function                                20  7  Signal Input  F11         SW1           0                                  21  8  Programmable Functions for F19 and   20                             22  9  Selecting Preset Output Frequency with  Multifunction Input Terminals 6 and 7                                  23  10  Recommended Fuse or Circuit Breaker Rating                          24  11  Reprogramming the Drive for 50 Hz Motor Operation                     30    TABLE OF CONTENTS  Continued              Tables Page  12  Function 223  F24  F28 Code Settings                                32  13  Functions 223  224  F28 Set for Automatic Restart for   All Faults Except      Power LOSS        cese          rac ean ed or o 33  14  Functions F23  F24  F28 Set for Automatic Restart for   All Faults Including AC Power Loss                                   34  15  Programmable Functions Summary List                            37  38  16  Multifunction Output Relay Operating                                        47  17  Fault Codes and Corrective Actions                                49  50  18  Status Indicators when the Drive is in External Start Stop Mode             51  19  Class B Residential Standard RFI Filters                               51  20  Brake Resistor Selection Chait                    pend wanda dd pase ae                   52  25 AG L
15.      Overvoltage and Undervoltage Protection     Shuts down the drive if the AC line  voltage goes above or below the operating range     Regeneration Protection     Eliminates tripping due to bus overvoltage caused by  rapid deceleration of high inertial loads     Stall Protection   Prevents the motor from stalling during startup of high inertial  loads     Short Circuit Protection     Shuts down the drive if a short circuit occurs at the motor   phase to phase or phase to ground      Electronic Motor Overload Protection          Prevents motor burnout and elimi   nates nuisance tripping due to overload     Overtemperature Protection     Shuts down the drive if the temperature exceeds  safe limits     OPTIONAL ACCESSORIES  See Section X  on page 51      Class B Residential Standard RFI Filter     Provides noise suppression for Class B  Residential Standard requirements  CE Directive 89 336 EEC      Note  All models are available with a built in Class A Industrial Standard RFI  Filter  Contact Sales Department     Brake Resistor Kit     Provides rapid stopping of the drive  Available for Models  KBE2 2202  2203  4301  4302  4303     DIN Rail Mounting Kit  DownLoad Module     DLM      Uploads and downloads drive programs     Drive Link    Software     Provides PC communications to facilitate programming   Uses Windows   95 98 2000 ME XP NT     Sec        Introduction  Cont            01                penunuoo   ejqer                   ynduy                84     nop          
16.      d  Press the DATA ENT key  The function value will be displayed  Factory  setting is    100     100  Full Load Rating of the Drive          Press the    or W RESET key until the desired value is displayed   Maintaining pressure on the    or W RESET key will cause the display to  change rapidly  The programmable range for F18 is 0 1   200         Example  If a 3 3 Amp motor is used with Model KBE2 2101  rated 4 2  Amps   F18 should be set according to the following formula      Current Rating of Motor   Current Rating of Drive  x 100   3 3 Amps   4 2 Amps  x 100   79   therefore  enter the function value     079    into F18           f  Press the DATAVENT key to save the new setting     F18    will be displayed     g  Press DSP FUN key to return to the frequency display or press the A or  W RESET key to change to another function number       205  Volts Hz Pattern      Volts Hz Pattern is used to set the drive for the  application in which it will be used  as described in Section IX  on page 40          is factory set to    004    for 60 Hz Constant Torque applications     a  The drive must be in stop mode  press the RUN STOP key      Press the DSP FUN key to display function number      Press the A or W RESET key until  FO5  is displayed      Press the DATA ENT key     004   will be displayed       Press the A or W RESET key until the desired setting is displayed  The  programmable codes for     5 are as follows     b                  05   001  50 Hz Constant Torque Appl
17.     he DSP FUN key       display function number     he A or W RESET key until  F20  is displayed     he DATA ENT key   is    005     Reset       The function setting will be displayed  factory    he A or W RESET key until code  006   Preset Speed  2  is dis        he DSP FUN key       return to the frequency display or press the    A or W RESET key to change to another function number     Note  F20 can be used to set the following functions  Jog   001     Preset Speed  1   002    Rapid Stop   003    Coast to Stop   004     Reset   005    factory setting   and Preset Speed  2   006       D  Programmable Functions  Summary List      All functions have been factory  set  as shown in Table 15  on pages 37 and 38  See Section IX  on page 39   for a detailed description of each function     36    Sec  VIII     Drive Operation  Cont                          uo penunuoo                                                                                         Sy 9  001 01  ZH  Aouanba4 Hejs exeig                    914  vy 90 5652 00          295        exe1g   04281              4015 01 15200   100      000             uonoelu               dojs oj uoneJeje  eq perjouuo   000            doS              00 001 00      15008 enboj                              ZH SHOA      H  ZHJ G1    600 2    01 900 ZHY 9  200  ev 500              800 2918  900 287 9  200            Aouanber4                  214  ZH 91  010 7HN2L 400     ZPLZ Z v00 2897  100                 200     4  or 000         
18.    0    ADL   0                         100 ped  oy  000               04002                             000 s 92 u09 doys uny                 100                  ped  ey  000    04 995   000 0015 1015 Old  iW 09 002 071  zH                        604  iW 001  002 071  ZH  Kouenba4   peads 195814 804  m 09 002 00  zH         490               11410    404  Or 009 002 01  2       add                    11400    904   QWAH               ejqeueA zH09  900  WAH  enbioj                ZHOS  200  0t 700                                2109  G00     anbuoy Hues u6rH 2609  200            ZH SHOA 504               1081500 zH09 2700              1uejsuo  2609  100  U0R29JI                   100  p 000                pJe J04  000 uonoelq                       51                 0  0015         100     6    000 doygasianay doig piemio4  000  014 999   041002 assanay do S psemso4               204       07  666 0                                                004  6   05 666   10  spuooes       uoneJeje2ov      104     hier                     uornoun uonduossag                              1611 AYVINWINS SNOILONNA 3 18VININVHDO8d   SI 318  1    37    Sec  VIII     Drive Operation  Cont          apoui        Y     SI          eui ejiuw                eq ULI 704 pue     904    05 204  104 10 sbuijjas  19449004                                10 Z pue 9 5           81 1             pue    900  01024    200  01 614 18S    EF paeds 195814 101 Z     ZH 09     090  01 904 pue   ZH 09      00  01
19.    FO  is used to set the output frequency lower  limit to the motor and is factory set to  00 0   which will operate the motor at a  minimum frequency of 0 0 Hz     Programmable Range  0   200 Hz  Note  F07 setting cannot exceed   06 setting     Motor Voltage        Sec  IX     Programmable Functions  Detailed   Cont         FIGURE 16     VOLTS Hz PATTERN  100                                                 pA    90  80  70  Constant Torque Application  High Starting Torque Application  60       Variable Torque  HVAC  Application                                                                                              0 10 20 30 40 50 60 70 80 90 100             Motor Frequency     Output Frequency Upper Limit  F06       F08    Preset Speed  1           Factory Setting     10 0     10 0 Hz          8 is used to set the frequency of Preset  Speed  1 and is factory set to    10 0     which will run the motor at 10 0 Hz if  Terminal    6    is selected  as described in Section V B 5  on page 22     Programmable Range  1   200 Hz    209     Jog Frequency   Factory Setting     06 0     6 0 Hz             is used to set the jog frequency         is  factory set to    06 0    which will run the motor at 6 0 Hz  To program the drive for  Jog operation  Multifunction Input Terminals    6    or    7    must be used  See F19 on  page 45 and F20 on page 46     Programmable Range  1   200 Hz  41    42    Sec  IX     Programmable Functions  Detailed   Cont         F10     Start Stop Co
20.    FOR ALL FAULTS INCLUDING AC POWER LOSS                                     Function   EET an  Number Function Description Code Value Description of Code Value  223 Auto Restart After    Fault 000 Enable Auto Restart After a  Has Cleared  Factory Setting  Fault Has Cleared  Number of Auto Restart 005     224 Attempts  Factory Setting is    000     Five Auto Restart Attempts       000         28 Automatic AC Line Start  Factory Setting is  001   Enable Automatic AC Line Start  001 External Contacts         Start Stop Control  Factory Setting is    000        Jumper Terms  3  amp  5 of TM2   4  F11  Frequency Control Method    Frequency Control Method is used to  set the drive for either keypad  potentiometer  voltage following  or current    34       following frequency control  as described in Section IX  on page 42  F11 is  factory set to    000     Keypad  to control output frequency with the keypad     Note  1  SW1 must also be set to the proper setting for voltage or current  signal input  as described in Section V B 1  on page 21     To change the setting of F11 from  000   Keypad  to    O01      External Contacts      a  The drive must be in Stop Mode  Press the RUN STOP key      Sec  VIII     Drive Operation  Cont         b  Press the DSP FUN key to display function number        Press the    or W RESET key until    F11    is displayed    d  Press the DATA ENT key  The function code will be displayed  factory  setting is    000     Keypad       e  Press the A or W RE
21.    to obtain Preset Speed  3  Terminals 6 and 7 must be programmed for  Preset Speeds  1 and  2  as described above  Use Function F27 to set  the frequency of Preset Speed  3     23    VI     24    d  Fourth Speed   To select a fourth speed  open connections to Terminals  6 and 7  of Terminal Block TM2  as shown in Figures 10A and 10B  on  page 23  This allows the fourth speed to be the speed set by the key   pad  remote potentiometer  or external signal input  depending on the  Frequency control Method  F1 1         C  Multifunction Output FIGURE 11   MULTIFUNCTION OUTPUT RELAY AND  Relay Connection     ANALOG OUTPUT VOLTAGE CONNECTIONS  Terminals 1 and 2 of  Terminal Block TM2 con  RELAY PWD REV  12 SPI RESET  10V VN OV     tain a normally open  NO  12342520678 9 10 11    relay contact  This con   tact changes state  depending on the drive TM2  operation and the setting  of Function F21  See   Section IX  on page 46    F21 is factory set to    O03     which sets the relay to operate as a Fault Relay   See Figure 11  In the Fault Mode  the relay will change state when any of the  following faults occur  OL1  OL2  OCS  OCA  OCC  OCd  OCb  OUC  LUC  and  OHC  The Output Relay can be programmed using Function F21 to operate as  a Run Relay  F21      000     or as a Frequency Reached Relay  F21      002         Note  The Output Relay contact is rated 1 Amp at 30 Volts DC or 250 Volts AC                                0 10 VDC             D  Analog Output Voltage Connection     A
22.   04 195 Ayeonewojne         ZH 09     020  01624 Dunes        06     050  01 904 pue  ZH 06     100  01 904 195                              ZH OS     010  01624               s810N                                                                               iG                    180             6 1527 5001   064   iG                                              623  pas      3v                  21485101  100   8b 100        aur  9v                          900        u                       824        voe 002   0 0 2 2    Aouanbaly gy peads 195814 123        002 002 00  zu  Aouanba4 2  peads 195814 924  uoneJedo 1043014              00400  ZH 09 10  BALI 19594  020   8r 000 uoneJado 4030Jy              1815007  ZH 06 40  BALI 19594 2010 1501198 fuot      enug 1959   Sed   Ly 0 5 0 sjdwany                            jequinN          lb 000 uejseg      9148510  L00 HeISeY ojny ejqeu3  000                                  e 19  uejseg ONY   24   lv 000 uny 9             9147510   00 ung 9519       814003  000 9 qesiq e qeu3 9519       224   9r   00           200                Aouanbar4  200 uny 2100        L                   Aejay dyno uonounjniniy 123  2            195944  900 dois pidey  200        500 19596 500 L4       0 195914  200 z 1 1           ynduj uonounyninyy   02     015 01 15209    00         100  24 09905 195814  900 dois pidey  200   Gb 200 19596  g00   peedg 195914  200 z 9 leutway        uonounynIN   614    015 01 15209    00         100   Gp 001 002      
23.   2  F01  Acceleration  Time      Used to set  the acceleration time  of the drive  The  acceleration time  can be changed  while the drive is in  the Stop Mode or  Run Mode  See  Figure 15     Example  Figure  15 illustrates the  sequence to  program FO1 for a  10 0 second accel   eration time     a  Press the  DSP FUN key to  display function  number     b  Press the    key unti    FIGURE 14     FLOW CHART TO CHANGE  SET FREQUENCY  DRIVE IN STOP MODE                                                           V   V          050              Iei A  PowerOn Set Frequency Press to Change New Set Frequency  Flashes Set Frequency is Displayed         Tu b      3 2     Press to Run the Drive Set Frequency  at the New is Displayed  Set Frequency          Note  In Run Mode  use the Up and Down keys to set the desired  frequency     FIGURE 15     FLOW CHART TO PROGRAM F01                                                                    ACCELERATION TIME   N      258     GD     F88           Power On Set Frequency Press to Function Number  Flashes Change Display is Displayed  0 Function Number              E p       A     Press 1 Time Acceleration Time Press to Display  0 Change Function Number Acceleration Time  Function Number is Displayed Setting  n n mn ___  050               100  Acceleration Time Press to Set New Acceleration Time  Setting is Displayed Acceleration Time Setting is Displayed                                              m    End     FU      Press to Enter Momenta
24.   34 35 0 63  40 45 0 49                     NOTES      55       XI  LIMITED WARRANTY   For a period of 18 months from the date of original purchase  KB Electronics  Inc   will repair or replace  without charge  devices which our examination proves to be  defective in material or workmanship  This warranty is valid if the unit has not been  tampered with by unauthorized persons  misused  abused  or improperly installed  and has been used in accordance with the instructions and or ratings supplied  The  foregoing is in lieu of any other warranty or guarantee  expressed or implied  KB  Electronics  Inc  is not responsible for any expense  including installation and  removal  inconvenience  or consequential damage  including injury to any person   caused by items of our manufacture or sale  Some states do not allow certain exclu   Sions or limitations found in this warranty and therefore they may not apply to you   In any event  the total liability of KB Electronics  Inc   under any circumstance  shall  not exceed the full purchase price of this product   rev 2 2000           COPYRIGHT    2003 by KB ELECTRONICS  INC     All rights reserved  In accordance with the United States Copyright Act of 1976  no part  of this publication may be reproduced in any form or by any means without permission in  writing from KB Electronics  Inc   8 22 02               KB  and  GENESIS  are registered trademarks of KB Electronics  Inc           KB Electronics  Inc          12095 NW 39th Street  C
25.   command is  given     b b     will flash on the display  To restart the drive  press the RUN STOP key  if F10 15  set to    000     Keypad Operation   or open and close the direction contact  if F10 is set to    001      External Run Stop Contacts       F19   005  Reset  Used to reset the drive after a fault has cleared     F19   006  Preset Speed  2  See F26  Preset Speed  2 Frequency  and F27  Preset Speed  3  Frequency      F20   Multifunction Input Terminal 7   Factory Setting     005     Reset      220 is used to set the function of Terminal 7 of  Terminal Block TM2  F20 is factory set to  005   which is used to reset the drive   after a fault has cleared  when Terminal 7 is connected to Terminal 5  Set F20 to  the desired function code as follows  See Section V B 5  on page 22        F20   001  Jog  See F09  Jog Frequency     F20   002  Preset Speed  1  See   08  Preset Speed  1 Frequency     F20   003  Rapid Stop  The drive will decelerate to stop when a momentary  Stop  command  is given   E S   will flash on the display  To restart the drive  press the RUN STOP key  if F10 is  set to  000   Keypad Operation   or open and close the direction contact  if F10 is set to 001    External Run Stop Contacts      F20   004  Coast to Stop  The drive will coast to stop when a momentary  Stop  command is  given   b b   will flash on the display  To restart the drive  press the RUN STOP key  if F10 is  set to  000   Keypad Operation   or open and close the direction contact  if
26.  00 5     which will apply the DC injection brake  for 0 5 seconds  The brake time should not exceed the actual time to stop the  load since it may cause overheating of the motor  See Figure 18        Programmable Range  0   25 5 seconds    Sec  IX     Programmable Functions  Detailed   Cont            F16     DC Injection Brake Start Frequency   Factory Setting     01 5     1 5 Hz      F16 is used to set the frequency at which DC  injection braking begins  F16 is factory set to    01 5     which will start applying the  DC injection brake at 1 5 Hz  See Figure 18  on page 44     Programmable Range  1   10 Hz    F17     DC Injection Brake Level    Factory Setting     08 0     8       F17 is used to set the DC injection brake level  as  a percent of bus voltage  F17 is factory set to    08 0     which will apply a DC  Injection Brake voltage of 8  of the bus voltage to the motor  See Figure 18  on  page 44        Programmable Range  0   20     Note  Do not increase the DC Injection Brake Level beyond what is necessary to  stop the motor since motor overheating may occur     F18     Electronic Motor Overload Protection  120        Factory Setting     100     100       F18 is used to set the maximum motor current   as a percent of the full load rating of the drive  F18 is factory set to    100     which  will allow loading the motor up to 100  of the full load rating of the drive  14 pro   vides motor overload protection which prevents motor burnout and eliminates nui   sance tr
27.  A Key   The A key is used to increase frequency  increase to the next high   er function number  or increase the function value or code setting  Pressing  the A key once will cause the display to increase by 1 unit  Maintaining pres   sure on the A key will cause the display units to increase rapidly     a  Ifthe drive is in Run Mode  press the A key to increase the run  frequenoy     27    Sec  VIII     Drive Operation  Cont         If the drive is in Stop Mode  press the A key to increase the set  frequency     If a function number is displayed  press the A key to increase the func   tion number to the next higher number     If a function value or code is displayed  press the A key to increase the  function value or code setting     5  W RESET Key   The    key is used to decrease frequency  decrease to  the next lower function number  decrease the function value or code set   ting  or reset the drive after a fault has occurred  Pressing the W RESET  key once will cause the display to decrease by 1 unit  Maintaining pressure  on the W RESET key will cause the display units to decrease rapidly     a     e     the drive is in Run Mode  press the W RESET key to decrease the  requency     the drive is in Stop Mode  press the W RESET key to decrease the  set frequency     a function number is displayed  press the W RESET key to decrease  he function number to the next lower number     a function value or code is displayed  press the W RESET key to  decrease the function value or
28.  F10 is set to    001      External Run Stop Contacts       F20   005  Reset  Used to reset the drive after a fault has cleared     F20   006  Preset Speed  2  See F26  Preset Speed 72 Frequency  and 227  Preset Speed 73  Frequency      Note  When using the Rapid Stop command  the stop method programmed by  F14  Stop Method  will be bypassed     F21   Multifunction Output Relay  Terminals 1 and 2     Factory Setting     003     Fault    F21 is used to set the function of the  Multifunction Output Relay  F21 is factory set to  003   Fault   which sets the relay  to function as a Fault Relay  and change state when a fault condition has  occurred  as shown in Table 16 on page 47  See Section V C  on page 24        F21   001  Run  002  Frequency Reached  003  Fault    Sec  IX     Programmable Functions  Detailed   Cont         TABLE 16     MULTIFUNCTION OUTPUT RELAY OPERATING MODES                      Output Relay Contacts  F21 Setting Power Drive In Drive In Frequency Fault  Off Stop Mode   Run Mode Reached  001  Run  Open Open Closed      002  Frequency Reached  Open Open   Closed     003  Fault  Open Open     Closed                      222     Reverse Enable Disable    Factory Setting     000     Enable Reverse Run      222 is used to enable or disable  the drive from operating in the reverse direction  F22 is factory set to    000      Enable Reverse Run  which will allow the drive to be operated in the reverse  direction        F22   000  Enable Reverse Run  001  Disable R
29.  Symbol   Failure to observe this warning could    result in electrical shock or electrocution              1 Operational Hazard Warning Symbol     Failure to observe this warning  could result in serious injury or death           v This product should be installed and serviced by a qualified technician  electri         V cian  or electrical maintenance person familiar with its operation and the haz   ards involved  Proper installation  which includes wiring  mounting in proper enclosure  fus   ing or other over current protection  and grounding can reduce the chance of electrical  shocks  fires  or explosion in this product or products used with this product  such as elec   ric motors  switches  coils  solenoids  and or relays  Eye protection must be worn and  insulated adjustment tools must be used when working with control under power  This  product is constructed of materials  plastics  metals  carbon  silicon  etc   which may be a  potential hazard  Proper shielding  grounding  and filtering of this product can reduce the  emission of radio frequency interference  RFI  which may adversely affect sensitive electron   ic equipment  lf further information is required on this product  contact the Sales  Department  It is the responsibility of the equipment manufacturer and individual installer  to supply this Safety Warning to the ultimate end user of this product   SW effective  11 1992                  This drive contains electronic Start Stop circuits that can be used to 
30.  as 1096 derating of the maximum output          rent  Reducing the switching frequency will provide increased motor torque   However  the audible noise will also increase      12   001  4 kHz 006  10 kHz  002  5 kHz 007  12 kHz  003  6 kHz 008  14 4 kHz  004  7 2 kHz 009  15 kHz  005  8 kHz 010  16 kHz    Motor Voltage        Sec  IX     Programmable Functions  Detailed   Cont         F13     Volts Hz Curve Modification  Torque Boost        Factory Setting     00 0     0 0        F13 is used to increase the percent of torque  boost that will be applied to the motor by modifying the Volts Hz patterns set by  205  as shown in Figure 17  F13 is factory set to    00 0     for 0 0  torque boost     Programmable Range  0   10 0     FIGURE 17     VOLTS Hz CURVE MODIFICATION  Torque Boost   100          90          80                         70          Constant Torque Application    Constant Torque Application with 10  Torque Boost     gt        60          50          40          30          2     0   10  Torque Boost    20                                                                               0 10 20 30 40 50 60 70 80 90 100    Motor Frequency  96  Output Frequency Upper Limit  F06          438    44    Sec  IX     Programmable Functions  Detailed   Cont         F14     Stop Method   Factory Setting     000     Controlled Deceleration to Stop   with DC Injection  Braking      F14 is used to select either controlled deceleration to stop or coast to   stop when a stop comman
31.  code setting     a fault has occurred  press the W RESET key to reset the drive     6  DATA ENT Key   The DATA ENT key is used to display or enter a func   tion s setting     a     the desired function number is displayed  press the DATA ENT key to  display the function value or code           the desired function value or code is displayed  press the DATA ENT  key to program the function to the new value or code   End  will be  momentarily displayed       Digital Keypad Operation   Examples of basic keypad operations are  described below     Note  When the DSP FUN key is pressed  the last function number will be dis   played  If the AC line is interrupted for more than 2 seconds  then    FOO    will  be displayed when the DSP FUN key is pressed     1  Setting Drive Output Frequency Using the Keypad   The drive is factory  set to run at 5 00 Hz when the drive is in the Run Mode   Press the  RUN STOP Key to start or stop the drive   See Figure 14 on page 29     a     To change the Set Frequency  drive in Stop Mode    1  Press the A or W key until the desired frequency is displayed     Sec  VIII     Drive Operation  Cont         2  Press the RUN STOP key to run the drive at the new Set Frequency     Note  Figure 14  is a flow chart  which illustrates  the sequence to  change and  program the Set  Frequency from  5 00 Hz to 32 1  Hz using the  keypad     b  To change the  Run Frequency   drive in Run  Mode   Press  the A or W key  until the desired  frequency is dis   played   
32.  direction using the keypad  F04 is factory set to    000    for forward  operation of the motor          04   000  Forward Direction  001  Reverse Direction    Note       order for the Reverse Function to operate  F22 must      set to    000      Enable Reverse Run   factory setting      205     Volts Hz Pattern   Factory Setting     004     60 Hz Constant Torque          5 is used to set the  Volts Hz pattern for 60 Hz and 50 Hz motors for constant torque  high starting  torque  or variable torque  HVAC  applications  as shown in Figure 16  on page 41          is factory set to    004    for 60 Hz motors used in constant torque applications   Also see the description for F13  Volts Hz Curve Modification  Torque Boost    on  page 43  which is used to modify a Volts Hz pattern for a specific application        F05   001  50 Hz Constant Torque  002  50 Hz High Starting Torque  003  50 Hz Variable Torque  HVAC   004  60 Hz Constant Torque  005  60 Hz High Starting Torque  006  60 Hz Variable Torque  HVAC     F06   Output Frequency Upper Limit       Factory Setting     60 0     60 0 Hz        06 is used to set the output frequency  upper limit to the motor and is factory set to  60 0   which will operate the motor  at a maximum frequency of 60 0 Hz     Programmable Range  1   200 Hz    Note  If the drive is set for 50 Hz motors  the Output Frequency Upper Limit will  automatically be set to 50 Hz        F07   Output Frequency Lower Limit    Factory Setting     00 0     0 0 Hz   
33.  ed with an AC line which will require the addition of a line reactor  multiple drives  on the same line  solenoids  power factor correction capacitors and machinery  switching    on    and  off   See Table 21 for the recommended AC Line Reactor     Sec  X   Optional Accessories  Cont                                                            AC Line Reactors can be purchased from ACME  MTE  and TCI   TABLE 21   RECOMMENDED AC LINE REACTOR SELECTIOIN CHART  5 AC Line AC Line Reactor Rating  Drive Model  rive Mode    Input Phase s  Volts      Amps AC mH  KBE2 2125 1 230 3 7        2 2150 1 230 5 2 4 2  KBE2 2101 1 230 94 21  1 230 19 1          2 2202  3  230 11 14  KBE2 2203 1 230 27 0 71  3  230 20 0 71  KBE2 4301 3  460 2 5 84  KBE2 4302 3  460 5 42  KBE2 4303 3  460 7 5 3 6   Note  For 3 phase AC line inputs  a 3 phase reactor or three 1 phase reactors must be used   H  AC Load Reactor   Eliminates false tripping when motor wires exceed 100    feet  30 m   See Table 22  for the recommended AC Load Reactor  AC Load          Reactors can be purchased from ACME  MTE  and TCI     Note  The voltage rating of the AC Load Reactor must be equal or greater than    the drive s nominal AC line input voltage rating     TABLE 22   RECOMMENDED 3 PHASE AC LOAD REACTOR SELECTION CHART                                              Motor Rating AC Load Reactor Rating    Nominal     Amps AC  Amps AC my  2 2 11  3 3 7 4  34 4 5 5  48 6 37  76 8 2 8  11 12 1 8  14 16 1 4  21 25 0 88  27 27 0 82
34.  ground the drive chassis using the green ground  Screw that is provided on the drive  as shown in Figures 3A and 3B  on page 18     Application Note     Do not    daisey chain  grounds to multiple drives and motors  Run  a separate ground wire from each motor and or drive to a central grounding point   17             Sec  IV   Term  Blocks     1 and        Wiring Inst   Cont      FIGURE          POWER CONNECTIONS for PKG  A and PKG      MODELS with 1   AC LINE INPUT                       4 112222          Ground 1p AC 3p AC   Earth  Line Input Induction Motor          FIGURE 3B     POWER CONNECTIONS for PKG  B  MODELS with 19 and 3p AC LINE INPUT              Optional    Ground 34 AC  Brake Resistor Induction Motor     Earth  Line Input          19 AC line input  use Terminals L1 L  and L3 N                 FIGURE 3C     POWER CONNECTIONS for PKG  C1  MODELS           4  with 1   and 3  AC LINE INPUT                    L1  L2 N   L2        L3  L3        230VAC Models  460VAC Models    Chassis  amp   amp  Chassis          AC Line Input  a d          1 AC Line Input  Sisi  use Terminals L1 L  and L2 N  Ground Optional   Earth   S0AC        prake Resistor  Induction Motor          C  Motor Connection     Wire the motor to Terminals T1 U   T2 V   T3 W  of  Terminal Block TM1  as shown in Figures 3A  3B  and 3C  on page 18  Motor  cable length should not exceed 100 feet  30 m      Application Notes     1  If wiring exceeds 100 feet  30 m   special Load  Reactors may be required  
35.  zero speed  from 60 Hz   after a stop or zero speed command is given     If the Set Frequency is greater than 60 Hz  the deceleration time will be proportion   ally increased  If the drive is set to less than 60 Hz  the deceleration time will be  proportionally decreased     When decelerating high inertial loads  the automatic regeneration protection circuit  may activate  This circuit will extend the deceleration time to prevent the drive  from tripping  due to overcharging the bus capacitors     Programmable Range  0 1   999 Seconds    203   External Forward Stop Reverse Control       Factory Setting     000     Forward Stop  Reverse Stop           is used to set the  drive for external forward stop reverse stop or run stop forward reverse control          is factory set to    000     Function F10 must      set to  001   External  Contacts   for external Start Stop operation  See Section V A  on page 20     F03   000  Forward Stop Reverse Stop  001  Run Stop Forward Reverse  Notes  1  If both the FWD and REV contacts are closed  the drive will be in Stop  Mode  2  If Reverse Operation does not function and  LOC  is displayed  change    F22  Reverse Enable Disable  to  000   Enable Reverse Run   If F22 is set to  001    Disable Reverse Run   the reverse command is disabled     39    40    Sec  IX     Programmable Functions  Detailed   Cont         204     Motor Direction   Factory Setting     000     Forward Direction      F04 is used to set either forward or  reverse motor
36. 0002020200  Terminal Block TM2 to     2             control motor speed  IT       Connect the high side  of the potentiometer to                    Terminal 8  the wiper 21    22      Voltage Following      Current Following      Multifunction Input Terminals 6 and 7    Sec  V   Term  Block TM2 Wiring Inst   Cont         to Terminal 9  and the low side to Terminal 10  as shown in Figure 7  on page  21  Set F11  Frequency Control Method  to    001     Potentiometer  and be sure  SW1 is set to the  V  position  factory setting   See Section       on page 42     FIGURE 8   VOLTAGE FOLLOWING CONNECTION  Connection   A 0 10       Volt DC analog signal RELAY PWD REV  12 SPI RESET  10V VN OV FM  input can be connect  12  y Erb BA ee 00 11                                ed to Terminal Block      2 to control motor  speed  Connect the  signal voltage     to  Terminal 9 and the                common     to Terminal  10  as shown in Figure 8  Set F11  Frequency Control Method  to    001      0   10 V  and be sure SW1 is set to the  V  position  factory setting      Note  F11  Frequency Control Method  is factory set to  000   Keypad      FIGURE 9   CURRENT FOLLOWING CONNECTION  Connection        0 20  mA DC or 4   20 mA  DC analog signal input  can be connected to  Terminal Block TB2 to  control motor speed   Connect the signal  current     to Terminal  9 and the common      to Terminal 10  as shown in Figure 9  Set SW1 to the    I    position        RELAY        REV  12 SPI RESET  10V 
37. A ENT key  The function code will be displayed   Factory setting is    000     Enable Auto Restart      5  Press the A key until    001     Disable Auto Restart  is displayed     6  Press DSP FUN key to return to the frequency display or press the  A or W RESET key to change to another function number     b  Automatic Restart for      Faults Except AC Power Loss    If the appli     cation requires that the drive automatically restart after a faul  except for an AC power loss  Function F24 must be set as  Table 13   Note  F23 and F24 are both factory set to  000       The faults that are automatically reset are indicated by  codes  OCS  OCA  OCC  OCd  OCb  OUV  LUC  OHC    To change the setting of F24 from  000  to  005    1  The drive must be in Stop Mode  press the RUN STOP    2  Press  3  Press  4      Press    displayed  Factory setting is    000              Press    6  Press       he DSP FUN key to display function number   he A or W RESET key until    F24    is displayed   he DATA ENT key  The number of restart attempts will be    he A key until    005     5 restart attempts  is displayed     A or W RESET key to change to another function number       The drive will res  onds  F23 set       has cleared   follows  See    he following    DSP FUN key to return to the frequency display or press the    art with a momentary power loss of less than 2 sec         000       TABLE 13   FUNCTIONS F23  F24  F28 SET FOR AUTOMATIC RESTART  FOR ALL FAULTS EXCEPT AC POWER LOSS         
38. SET key until the desired setting is displayed  The  programmable codes for F11 are as follows     F11   000  Keypad  Factory Setting   001  Potentiometer  0   10 V  0   20 mA  002  4 20 mA    f  Press DSP FUN key to return to the frequency display or press the A or  W RESET key to change to another function number       F10  Start Stop Control    Start Stop Control is used to set the drive for  keypad  factory setting  or external Start Stop Control  as described in  Section IX  on page 42  F10 is factory set to  000   Keypad      WARNING  The Stop contact is never to be used as a Safety Disconnect  Since it is not fail safe  Use only the AC line for this purpose    To change the setting of F10 to External Contacts    a  The drive must be in Stop Mode  press the RUN STOP key     b  Press the DSP FUN key to display function number    c  Press the    or W RESET key until    F10    is displayed    d  Press the DATA ENT key  The function code setting will be displayed    factory setting is    000                      e  Press the A or W RESET key until code    001    is displayed     f  Press DSP FUN key to return to the frequency display or press the A or  W RESET key to change to another function number     Notes  1  In order for the reverse function to operate  Function F22  must be set to  000   Enable Reverse Run   factory setting   2  The  STOP key on the keypad is always operative  even if F10 is set to  001    External Contacts                External Forward Stop Revers
39. URE 20     DLM CONNECTIONS       DLM to Drive Connection PC to DLM Connection  DownLoad Module  DownLoad Module    Part No  14145  Adjustable Frequency Drive   Part No  14145                   m Drive Link    Software with             Serial Communication Cable   Part No  14165                                                           GIGIGIOI9                                                      For Drive Link    Software with  USB Communication Cable   Order Part No  14166                KBE2 to DLM Communication Cable  Part No  14147                 PC to DLM to Drive Connection    DownLoad Module      Part No  14145     Adjustable Frequency Drive                Drive Link    Software with  Serial Communication Cable   Part No  14165                                                                                For Drive Link    Software with  USB Communication Cable   Order Part No  14166                         KBE2 to DLM Communication Cable  Part No  14147               Drive Link    Software  Part No  14165      Provides PC communications to  facilitate programming  Uses Windows   95 98 2000 ME XP NT  Requires  DownLoad Module     DLM   Part No  14145  and KBE2 to DLM Serial  Communication Cable  Part No  14147   See Figure 20  For Drive Link     Software with USB cable  order Part No  14166        53    54    G  AC Line Reactor     Eliminates erratic operation or tripping due to    noisy or  unstable AC power source  The following are some typical problems associat  
40. VN OV FM  12 3 4 5 6 7 8 91011    00990000022                 For 4   20 mA DC analog signal input  set F11  Frequency Control  Method  to    001        b  For O   20 mA DC analog signal input  set F11  Frequency Control  Method  to    002           TABLE 8   PROGRAMMABLE    Connection     The Multifunction Input FUNCTIONS FOR   19 and F20          Terminals are factory programmed for 001         Preset Speed  1  Terminal    6    SP1  and 002 Preset Speed  1  Reset  Terminal    7    RST   Each terminal   008   Rapid Stop       004 _ Coast to Stop  can be programmed for six functions 005 Reset  using Function Numbers F19 for 006 Preset Speed  2    Terminal  6  and F20 for Terminal  7               See Table 8  Figures 10A  10B  and Table 9 on page 23     Sec         Term     Block TM2 Wiring Inst   Cont         Preset Speed  Operation  Many  applications require  preset speed opera        tion  The KBE2 is  capable of providing  3 preset fixed  speeds using  Terminals    6    and     7    plus a fourth set  speed  See Table 9        FIGURE 104 FIGURE 10B  MULTIFUNCTION MULTIFUNCTION INPUT  INPUT TERMINAL TERMINAL OPEN COL    CONNECTIONS LECTOR CONNECTIONS   12 91 RESET  12   lt            5 7 5 6 7                            PRESET SPEED  1    SPEED  1    RESET   PRESET  SPEED  2     RESET   PRESET  SPEED  2                 Terminal 6 has been       factory programmed to Preset Speed  1  FO8 programs the frequency    Terminal 7 has been factory programmed to reset the drive  T
41. also be used    1  Signal Input Type Selection  SW1      FIGURE 6A   SW1 Set for  SW1 selects the external signal type to Remote Speed Potentiometer or  be used to control motor speed  SW1 is Voltage Following Signal Input  factory set to the  V  position for 0   10 Volts DC  voltage following signal input or remote speed   U       potentiometer control  as shown in Figure 6A  For  0   20 mA or 4   20 mA DC current following sig   nal input  set SW1 to the  I  position  as shown in Swi  Figure 6B  Set F11  Frequency Control Method  to  the appropriate setting for the signal type being  used  as described in Section IX  on page 42                 FIGURE 6B     SW1 Set for       Location of SW1  Current Following Signal Input  a  To access SW1 on panel mount models    remove the small cover that is located on the     right side of the drive  above Terminal Block     TM2  by gently sliding it upwards  Replace the Y   cover after setting SW1 as described above  SW          b  To access SW1 on          4   IP 65 models   remove the four screws which secure the cover  SW1 is located near  the top right side of Terminal Block TM2  Replace the cover and the  four screws after setting SW1 as described above  Tighten but do not  over tighten these screws           FIGURE 7   REMOTE          2  Remote Speed SPEED POTENTIOMETER CONNECTION  Potentiometer  Connection        5kQ RELAY FWD REV  12        RESET  10V VN OV      or 10k  remote 2002           Y  380595 AO  can be connected to 02
42. and 230 VAC 14 E 12 M  are e B        HP 22D AG 12 33 16 19  Brake Resistor  P  R  1HP  2 HP  3 HP   460         AC Line  L1  L   L2       L3  thru 1 HP   115         Motor  T1  T2  T3     and 230 VAC a 2    14       p  eS C1 2 Hrs HE 29046 12 3 3 7 8  Brake Resistor          1 HP  2 HP  3 HP   460                                   Note  To access terminals on NEMA 4X models  remove the four screws which  secure the cover  Replace the cover and the four screws after wiring is complete   Tighten but do not over tighten these screws    AC Line Connection    Note  Be sure the drive rated AC line voltage  115  208 230  380 460 Volts AC   matches the actual AC line input voltage     1  Single phase only AC line input models  Pkg  A and Pkg  C   wire the AC line to  Terminals L1  L2  as shown in Figure 3A  on page 18     Note  If one of the AC line inputs is a neutral        wire it to Terminal L2     2  Dual phase  1   3   AC line input models  Pkg  B   wire the 1 AC line to  Terminals L1 L   L3 N   as shown in Figure 3B  on page 18     3  Dual phase  1   3   AC line input models  Pkg  C1   wire the 19 AC line to  Terminals L1 L   L2 N   as shown in Figure 3C  on page 18     4  Dual phase  1   3   AC line input models  Pkg  B   wire the 3  AC line to  Terminals L1  L2  L3  as shown in Figure 3B on page 18     5  3 Phase only AC line input models  Pkg  B and Pkg  C1   wire the AC line to  Terminals L1  L2  L3  as shown in Figure 3B  on page 18              Ground Connection   Earth
43. arquie 99npaJ                                                 00  1 aunqesadwua  juaiquiy     edad 10           ayy uunjag    anoajap si          uonoejeg         00  51              yndul            n                            128110          00  SI              aur    reda 10  9Aup      unge                    s                                                                             001 s                1ndur                                      BY  128105  UB 00  s               aur             10           au uunjag                   S   NOHd33 1049  N0ud33 ud3                eyeudojdde ppy                          95104 40118                349  uonsy 941291103 asneg 81124044 uondussag pui                   SNOILOV 3ALLO3HHOO        53  02 Linvs   21 3 18VL    o        Sec  IX     Programmable Functions  Detailed   Cont             Suras A401984  fine     200  01195 s          Inding uorounyniny  124 JI 8115                   Aejay 114400      asneo Im        syne                                                                    204 uey                                         904 195  aures ay         Dunjas                   04 pue 904 40118          Aouenba4 23            10               Buluuns si                    pabueyo  uoljoun                   uay  pue          aui dois      jouueo zey                 e                                195   101024       01519                     624              0  1                                     ped  ay            
44. cally restart after a fault has cleared   including an AC power loss     000    005  000 Note  Function F10 must be set to  001   External Contacts   and a jumper must be installed between Terminals 3 and 5 of  Terminal Block TM2                          Indicates factory setting    AC power loss of under 2 seconds     The faults that can be manually or automatically reset are indicated by the following codes   OCS  OCA  OCC  OCd  OCb  OUC  LUC  OHC  See Table 17  on pages 49 and 50     a  Manual Restart   The drive is factory programmed to be manually  restarted whenever a fault occurs  see Table 17  on pages 49 and 50    F23  Auto Restart After A Fault Has Cleared  is factory set to    000      Enable Auto Restart   In this mode  the drive must be restarted for      faults except for a momentary AC power loss  If amomentary AC power  loss  under 2 seconds  occurs  the drive will shut down causing the motor  to slow down or stop  depending on the load type  and then accelerate  to the set frequency  If the application requires that the drive shut down  even during a momentary AC power loss  set F23 to    001     Disable Auto  Restart      Sec  VIII     Drive Operation  Cont         To change the setting of F23 from    000  to  001      1  The drive must be in Stop Mode  press the RUN STOP key   The  set frequency will flash on the display     2  Press the DSP FUN key to display function number   3  Press the    or W RESET key until    F23    is displayed     4  Press the DAT
45. contact our Sales Department  See Section X F   Table 22  on page 53  2  Be sure the motor rated voltage  208 230  380 460  Volts AC  matches the control output voltage     D  Optional Brake Resistor Connection   To improve braking  an optional brake  resistor can be connected to Terminals  P  and  R   as shown in Figure 3B  on  page 18  This optional brake resistor can provide maximum braking torque of  up to 13096  model dependent   This option is only available for Models KBE2   2202  2203  4301  4302  and 4303  See Section X D  on page 52     CAUTION  To avoid overheating  do not mount the optional brake resistor  under the drive        TERMINAL BLOCK TM2 FIGURE 4A   PKG  A   WIRING INSTRUCTIONS TERMINAL BLOCK TM2 LAYOUT   Signal Connections    The       2 contains 11 signal RELAY        REV  12 SPI RESET  10V VN OV FM    erminals which can be used 12 3 4 5 6 7 8 9 9 t    or various functions  For ooooooooooo    Terminal Block TM2 wiring  information  see Table 5              FIGURE 4B   PKG  B  PKG  C  PKG  C1          IMPORTANT  See TERMINAL BLOCK TM2 LAYOUT  Application Notes  in  Section IV  on page 16  RELAY FW RE 12V SP RS 10V V OV FM             200000000222    Notes  1  If external signal Q0 0 8 6 8 6 0 6 9           wiring is not used  proceed to  Section VI  on page 24                    2  Terminal  5  TABLE 5   TERMINAL BLOCK TM2     12V  is the supply WIRING INFORMATION   voltage for the      Start Stop circuit Supply Wire Range Recommended  andithe  Cu  Tigh
46. d is given  The controlled deceleration function uses a  combination of regeneration and DC injection braking to stop the motor  The facto   ry setting utilizes regeneration as the primary method of braking  When the output  frequency reaches 1 5 Hz  injection braking takes effect  For high inertial loads  the  optional Brake Resistor may be required  available for Models KBE2 2202  2203   4301  4302  4303 only   See Section X D  on page 52  If F14 is set to    000      Controlled Deceleration to Stop  and a stop command is given  the drive output will  decelerate to the braking frequency set by F16  DC Injection Brake Start Frequency    See Figure 18 and descriptions of F15  DC Injection Brake Time   F16  DC Injection  Brake Start Frequency   and F17  DC Injection Brake Level      F14   000  Controlled Deceleration to Stop  with DC Injection Braking   001  Coast to Stop    FIGURE 18   CONTROLLED DECELERATION TO STOP  WITH DC INJECTION BRAKING  F14 Set to    000                              Motor Running at Set Frequency  Stop Command           Frequency  Motor Slows by Regenerative Braking Until the  DC Injection Brake Start Frequency is Reached       o  5    DC Injection Brake     Start Frequency    16         15    a DC Injection  5 Brake Level    17      0     1 DC Injection  Time  Seconds  Brake Time    15              F15     DC Injection Brake Time    Factory Setting     00 5     0 5 Seconds      F15 is used to set the DC injection  brake Time  F15 is factory set to   
47. e Control      External Forward Stop   Reverse Control is used to set the drive for either Forward Stop   Reverse Stop  factory setting  or Run Stop Forward Reverse  as described  in Section IX  on page 39     35    Sec  VIII     Drive Operation  Cont         1 WARNING  The Stop contact is never to be used as a Safety Disconnect  since it is not fail safe  Use only the AC line for this purpose     To change the setting of FO3 to Run Stop Forward Reverse   The drive must be in Stop Mode  press the RUN STOP key      a   b            Press  Press    Press  setting    Press          Press    he DSP FUN key       display function number     he A or W RESET key until              is displayed     he DATAVENT key     The function code will be displayed  Factory    is    000     Forward Stop Reverse Stop    he A or W RESET key until code  001   Run Stop        Forward Reverse  is displayed        he DSP FUN key       return to the frequency display or press the    A or W RESET key to change to another function number     7  Setting F20 for Preset Speed  2   Multifunction Input Terminal 7 is used  to set various functions for operating the drive  F20 is factory set to    005      Reset  to reset the drive after a fault has cleared  See Preset Speed oper   ation in Section V B 5  on page 23        To change the setting of F20 to Preset Speed  2   The drive must be in Stop Mode  press the RUN STOP key      a   b     C     Press  Press    Press  setting    Press       played        Press
48. e the keypad with a screwdriver or other  sharp ended tool     A  Digital Keypad Description     The digital keypad has 5 keys and a display  which are used to program drive functions and control various features  as  described below  See Figure 18  on page 27     1  3 Digit LED Display     When power is applied to the drive  the LED  located  at the top left side of the digital display  will illuminate  The digital display will  flash the set frequency  factory setting is    05 0     When the drive is in Stop  Mode  the set frequency is displayed  When the drive is in the run mode  the  output frequency is displayed     2  RUN STOP Key   The RUN STOP key is used to run or stop the drive  a  If the drive is in Stop Mode  press the RUN STOP key to start the drive   b  If the drive is Run Mode  press the RUN STOP key to stop the drive     Sec  VIII     Drive Operation  Cont         3  DSP FUN Key     The DSP FUN key is used to change the display between  Display Mode and Function Mode     a  If DSP FUN is pressed while frequency is displayed  the display will indi   cate a function number     b  If DSP FUN is pressed while a function number is displayed  the display  will change to the output frequency setting     Note  When the DSP FUN key is pressed  the last function number will  be displayed  If the AC line is interrupted for more than 2 seconds  then     FOO    will be displayed when the DSP FUN key is pressed     FIGURE 13   DIGITAL  KEYPAD LAYOUT    Power On LED       4 
49. east  300V rated wiring is  used on 115 230 Volt  AC models and 600V  rated wiring is used  on 460 Volt AC models  Recommended insulation type is    XLPE     Do not use  type                 If motor wires exceed 100 feet  30      a Load Reactor may be  required   Do not use insulation type    THHN      See Section X H  Table 22  on  page 54  The 3 phase input voltage imbalance must be less than 3                          ru 2      230       Models   amp  460VAC Models                      2  To Avoid Erratic Operation   Do not bundle signal wires  start stop  frequen   cy control  etc   with AC line or motor wires  Use shielded cables on signal  wiring over 12   30 cm   The shield should be Earth grounded on the drive side  only  Wire the drive in accordance with the National Electrical Code and other  local codes that may apply  See Figures 3A  3B  and 3C  on page 18     Be sure to properly fuse each AC line conductor that is not at ground poten           Sec  IV     Term  Blocks TM1 and        Wiring Inst   Cont         tial  Do not fuse neutral or grounded conductors  A separate AC line switch  or contactor must be wired as a disconnect so that each ungrounded  conductor is opened  See Section VI  on page 24     TABLE 4     TERMINAL BLOCKS     1 AND        WIRING INFORMATION                      Maximum Recommended  Wire Size  Cu  Tightening Torque   Terminal Description Pkg  Horsepower AWG       in Ibs kg cm  AC Line  L1  L2  thru 1 HP   115         Motor  T1  T2  T3    
50. everse Run    Note  If F22 is set to    001     Disable Reverse Run   F04  Motor Direction  can only  be programmed to  000   Forward Direction      F23   Auto Restart After a Fault has Cleared    Factory Setting     000   Enable Auto Restart      F23 is used to enable or disable  automatically restarting the drive after a momentary power loss  not exceeding 2  seconds   F23 is factory set to    000     Enable Auto Restart   which will automati   cally restart the drive after a momentary power loss  To set the drive for manual  restart  after a momentary power loss  set F23 to  001   Disable Auto Restart         F23   000  Enable Auto Restart  see note below   001  Disable Auto Restart    Note   f the power loss time does not exceed 2 seconds  Auto Restart will occur   If the power loss time exceeds 2 seconds  Auto Restart will be attempted only if  F24  Number of Auto Restart Attempts  is set to  001     005      F24   Number of Auto Restart Attempts    Factory Setting     000   Zero Auto Restart Attempts      F24 is used to set the  number of Auto Restart Attempts that will be performed after a fault has cleared   224 is factory set to    000     Zero Auto Restart Attempts   which will not allow the  drive to automatically restart after a fault has cleared        Programmable Range  0   5 Auto Restart Attempts    47       48    Sec  IX     Programmable Functions  Detailed   Cont         F25     Reset Drive to Factory Settings       Factory Setting     020     60 Hz Operatio
51. fail safe  Use only the AC line for this purpose                                                           Note  Open collec  TABLE 6     EXTERNAL START STOP CONTROL  tors may be used in USING FUNCTION         lieu of contacts  See  Figure 5B  Function F03 Contact Status Drive  Code Setting   Term  3  FWD    Term  4  REV    Operation    External Frequency 000 ven Open Stop  Control     Terminals  Factory osed Open Forward  8  9  and 10 can be Setting  Open Closed Reverse  wired in a variety of Closed Closed Stop  ways to control the Open Open Stop  output frequency of 001 Closed Open Forward  the drive  as shown in Open Closed Stop  Figures 7  8 and 9  Closed Closed Reverse  on pages 21 and 22   See Table 7 on page 21  F11  Frequency Control Method  is used to program  the drive to control motor frequency with an external signal instead of the key           pad  as described in Section IX  on page 42  F11 is factory set to    000      Keypad   SW1 is used to set the drive for voltage or current input signal  as  described in Section V B 1  on page 21  SW1 is factory set to the  V  position   Keypad  Potentiometer  O   10 Volts DC      Sec         Term  Block TM2 Wiring Inst   Cont         TABLE 7     SIGNAL INPUT  F11  and SW1 SETTING                         Frequency Control Method F11 Code Setting SW1 Position  Keypad  Factory Setting  000  Factory Setting   5 kQ Potentiometer  001 oW anh  0   10 Volts DC 001  0   20 mA DC 001  4   20 mA DC 002                  10      may 
52. ication  002  50 Hz High Starting Torque Application  003  50 Hz Variable Torque  HVAC  Application  004  60 Hz Constant Torque Application  Factory Setting   005  60 Hz High Starting Torque Application  006  60 Hz Variable Torque  HVAC  Application 31       Sec  VIII     Drive Operation  Cont         f  Press DSP FUN key to return to the frequency display or press the A or  W RESET key to change to another function number     Notes  1  Programming     5 is related to the motor characteristics not  the AC line input frequency  50 60 Hz   2  Codes    003    and    006            used for variable torque loads such as fans  blowers  or centrifugal  pumps   3  F23  F24  F28 for Manual or Automatic Restart  After A Fault Has  Cleared      See Table 12  for    summary of manual and automatic restart  unction settings           WARNING  Do not set the drive for automatic restart  unless     automatic restart will not cause serious injury      death        TABLE 12     FUNCTION F23  F24  F28 CODE SETTINGS       Function Code Setting  F23 F24 F28   Description    The drive must be manually restarted after a fault has cleared   except for a momentary AC power loss             000      000    001        The drive must be manually restarted after    fault has cleared     001 000 001 including a momentary AC power loss          The drive will automatically restart after a fault has cleared but    000 005 001 must be manually restarted after an AC power loss        The drive will automati
53. indicated by the follow   ing codes  OCS  OCA  OCC          OCb  OUC  LUC  OHC   See Table 17  on  pages 49 and 50      Notes  1       order for the drive to automatically restart after a fault has cleared   including AC line restart  set F23 to  000   Enable Auto Restart   F24 to  005   Five  Auto Restart Attempts   and F28    000   2  F10 must be set to  001   External  Contacts  and a jumper must be wired to Terminals 8 and 5 of Terminal Block TM2     Programmable Functions  Detailed  is continued on page 51     Sec  IX     Programmable Functions  Detailed   Cont          05            uo penunuoo                          A101924            200  01195 51  Aejay ndino                       124 4  91215                   Aejay INdynQ ayy esnea      YIM syne4          21 4  18497 ayerg                                               00             jana  oxe1q uonoefur                                                                                                           914  Aouanbas4 ueis exe1g uonoefu    y                        AouanbaJ  11815 ayesg uoroefur 20 199409U                                                   920   G14        ayeig uonoefu                                                     euin exe1q uonoefur 90      004            euin                             9589120         00          5 aui                                                                                   990  11012891             150  Bins Jamod jusisuel   KouanbaJ 195 e JUBNDGAQ    990   
54. ine Reactor Selection  Ghart  sr esae          ei race      Ea         54  22       Load Reactor Selection                                             54  Figures        Mechanical Specifications for Models   KBE2 1125 P  1150     1101 P  2125     2150     2101 P  Pkg                12  1B  Mechanical Specifications for Models   KBE2 2202 P  2203 P  4301 P  4302 P  4303     Pkg  B                   13  1C  Mechanical Specifications for Models   KBE2 1125 4  1150 4  1101 4  2101 4  Pkg                             14  1D  Mechanical Specifications for Models         2 2202 4  2208 4  4301 4  4302 4  4303 4  Pkg  C1                  15  2A  Pkg  A and Pkg  C Terminal Block TM1 Layout                          16  2B  Pkg  B Terminal BlOGK        Layout ie cae coe p mee rab eg          16  2C  Pkg  C1 Terminal Blocks TM1 and        Layout                          16  3A  Power Connections for Pkg  A and Pkg  C Models   with  AG Line Input d  du ERR               SR               RIS NET 18  3B  Power Connections for Pkg  B Models   with Tar and 3s AC LING PU a se cU ee x ey edhe ee EO 18  3C  Power Connections for Pkg  C1 Models   wiht Tr and 3h AG Line InDUE                    Y                         18  4A  Pkg  A Terminal Block TM2 1                                            19  4B  Pkg  B  Pkg      and Pkg  C1 Terminal Block TM2 Layout                 19  5A  External Start Stop Forward Reverse Connections                       20    TABLE OF CONTENTS  Continued        Figu
55. ions include  3  pre   set speeds  analog output signal  0   10 Volts DC   and a programmable output relay     The KBE2 also contains the following protection features  undervoltage  overvoltage   overtemperature  ground fault  short circuit  and Pt motor overload protection  The  fault codes are shown in the digital display  All models are UL Listed  USA and  Canada   CE and C tick  N10980  approved and ISO 9002 certified     Optional features include a DIN Rail Mounting Kit and RFI filter  An external brake  resistor is available for 2 HP and 3 HP   230 Volt AC models and 1 HP  2 HP  and 3  HP   460 Volt AC models  The DownLoad Module    DLM  uploads and downloads  drive programs  Drive Link    software provides PC communications to facilitate  programming     STANDARD FEATURES    Keypad   Used for drive operation and programming     3 Digit LED Display     Provides indication of drive status and programming   Frequency  Functions  Fault Codes      Voltage Current Switch   Selects either voltage potentiometer or current  signal input     Regenerative and DC Injection Braking     Provides controlled rapid stopping     Short Circuit Protection     Shuts down the drive if a short occurs at the motor   phase to phase or phase to ground      Barrier Terminal Blocks   Separate terminal blocks are provided for power        line  motor  and external signal wiring  potentiometer  multifunction input and  output terminals  voltage and current following      2 Multifunction Control In
56. ips due to overload  The drive is factory set to trip at 150  of F18 setting  in 1 minute  To reset the drive  after it has tripped  press the W RESET key or  activate an external reset contact wired to Terminal 7 of Terminal Block TM2     Programmable Range  1   200     Example  If a 3 3 Amp motor is used with Model KBE2 2101  rated 4 2 Amps    F18 should be set according to the following formula      Current Rating of Motor   Current Rating of Drive  x 100   3 3 Amps   4 2 Amps  x 100   79   therefore  enter    O79    into F18     F19     Multifunction Input Terminal 6    Factory Setting     002    Preset Speed  1     F19 is used to set the function of  Terminal 6 of Terminal Block TM2  F19 is factory set to    002     which will run the  drive at the frequency set by   08  Preset Speed  1 Frequency  when Terminal 6 is  connected to Terminal 5  See Section V B 5  on page 22        F19   001  Jog  See F09  Jog Frequency    F19   002  Preset Speed  1  See F08  Preset Speed  1 Frequency      F19   003  Rapid Stop  The drive will decelerate to stop when a momentary    Stop    com   mand is given     E S     will flash on the display  To restart the drive  press the RUN STOP key   if   10 is set to    000     Keypad Operation   or open and close the direction contact  if F10 is  set to   001     External Run Stop Contacts       45    46    Sec  IX     Programmable Functions  Detailed   Cont         F19   004  Coast to Stop  The drive will coast to stop when a momentary    Stop  
57. n      F25 is used to reset the drive to fac   tory settings for both 50 Hz and 60 Hz motors     F25   010  Reset Drive for 50 Hz Constant Torque Motor Operation  020  Reset Drive for 60 Hz Constant Torque Motor Operation    Note  Setting F25 to    010     50 Hz  will automatically set FOS  Volts Hz Pattern  to     001     50 Hz  and FO6  Output Frequency Upper Limit  to    O50     50 Hz   Setting  F25 to  020   60 Hz  will automatically set FO5 to    004     60 Hz  and        to    060      60 Hz      F26   Preset Speed   2 Frequency    Factory Setting     20 0     20 0 Hz      F26 is used to set the Preset Speed  2 fre   quency  F26 is factory set to 20 0   which will run the motor at 20 0 Hz  See  Section V B 5  on page 22        Programmable Range  01 0   200 Hz    F27   Preset Speed   3 Frequency    Factory Setting     30 0     30 0 Hz      F27 is used to set the Preset Speed  3 fre   quency  F27 is factory set to 30 0   which will run the motor at 30 0 Hz  See  Section V B 5  on page 22        Programmable Range  01 0   200 Hz    F28   Automatic AC Line Start    Factory Setting  001  Disable Automatic AC Line Start      228 is used to enable  or disable automatic starting of the drive when the AC line is applied  F28 is facto   ry set to  001   which will disable automatic starting of the drive when the AC line  is applied        F28   000  Enable Automatic AC Line Start  001  Disable Automatic AC Line Start    The faults that can be manually or automatically reset are 
58. n analog output voltage  0 10 Volts DC   is provided at Terminals 10     and 11    of Terminal Block TM2  This voltage is  proportional to the Output Frequency Upper Limit set with FO6  See Figure 11     AC LINE FUSING   This drive does not contain AC line fuses  Most electrical codes require that each  ungrounded conductor contain circuit protection  It is recommended to install a fuse  or circuit breaker in series with each ungrounded conductor  Do not fuse neutral or  grounded conductors  See Table 10  Check all electrical codes that apply to the  application  Do not install a fuse or circuit breaker in series with motor leads     TABLE 10   RECOMMENDED FUSE OR CIRCUIT BREAKER RATING                                        Model Rating  Amps AC  Model Rating  Amps AC   KBE2 1125 15 KBE2 2202 20  15   KBE2 1150 15 KBE2 2203 30  15   KBE2 1101 30 KBE2 4301 15  KBE2 2125 15 KBE2 4302 15  KBE2 2150 15 KBE2 4303 15  KBE2 2101 20 f    Rating is for 19   3           FIGURE 12     HI POT SETUP    ewes                  40                                     OV  Iv 0   10d IH                                      JO1OIA                eAug Aouenbei4 ajqeisnipy     pe1oeuuoosiq Je og         0832                                     5  HAL      1                                                            OV           soon     12182 10d 1H               pueisuiM                              ubiH    25    Vil     Vill     26    RECOMMENDED HIGH VOLTAGE DIELECTRIC   WITHSTAND TESTING  Hi P
59. ntrol    Factory Setting     000     Keypad Operation      F10 is used to set either keypad  operation or external start stop control  F10 is factory set to    000     which pro   vides start stop control with the keypad   Also see F03         F10   000  Keypad Operation  001  External Run Stop Contacts    Note  If F10 is set to  001   External Run Stop Contacts   the Stop Function on  the keypad  RUN STOP key  remains operational     F11   Frequency Control Method       Factory Setting     000     Keypad Operation      F11 is used to set the drive for  either keypad control or external signal input control  speed potentiometer  O   10  V  O   20 mA DC  or 4   20 mA DC   F11 is factory set to    000     to operate the  drive using the keypad     F11   000  Keypad    001  Speed Potentiometer  0   10 V DC  0   20 mA DC  002  4   20 mA DC    Note  If a remote speed potentiometer or a      10 Volt DC signal is used  set SW1  to the  V  position  factory setting   If a O   20 mA DC or 4   20 mA DC signal is  used  set SW1 to the 4    position  See Section V B  starting on page 20     F12     Switching Frequency       Factory Setting     005   B kHz      F12 is used to set the switching frequency  F12  is factory set to    O05     for a switching frequency of 8 kHz  which provides low  motor noise and good motor torque  Increasing the switching frequency to the  maximum of 16 kHz will further reduce motor noise  However  increased radio fre   quency interference will result as well
60. o program  Terminal 7 to Preset Speed  2  use Function F20  Multifunction Terminal 7   set to    006     as described in Section           7  on page 36     TABLE 9     SELECTING PRESET OUTPUT FREQUENCY WITH  MULTIFUNCTION INPUT TERMINALS 6 AND 7                         Preset Speed Terminal 6   Terminal 7   Function       to Program Output Frequency  1 Closed Open   08  10 0 Hz    2 Open Closed F26  20 0 Hz    3 Closed Closed F27  30 0 Hz    Keypad   Factory Setting  Open Open Set by  amp  and W RESET Keys                  Indicates factory setting of preset speed frequency  Hz      Note    19 is used to program Term  6 to Preset Speed  1  220 is used to program  Term  7 to Preset Speed  2  Close both Terms  6 and 7 for Preset Speed  3  when  switching Terms  6 and 7 together  the operation must be within 10 mSeconds      a  Preset Speed  1     Connec  Figures 10A and 108  Note  F19 must be set to    002      factory setting   Set FO8 to    TM2  as shown in    b  Preset Speed  2  TM2  as shown in      Connec  Figures 10A and 108  Set F20 to    006     Preset Speed    Terminal 6 to Terminal 5  of Terminal Block    the desired output frequency     Terminal 7 to Terminal 5  of Terminal Block     2  and set F26 to the desired output frequency     c  Preset Speed  3                      Terminals 6 and 7  of Terminal Block TM2     to Terminal 5  as shown in Figures 10A and 10B  when switching Terms        6 and 7 together     he operation must be within 10 mSeconds   In order    
61. oral Springs  FL 33065 2516      954  346 4900 Fax  954  346 3377    Outside Florida Call TOLL FREE  800  221 6570     E mail     info kbelectronics com  www kbelectronics com     A98015      Rev  B1     8 2003    
62. ot    Testing agencies such as UL  CSA  etc   usually require that the equipment under   go a hi pot test  In order to prevent catastrophic damage to the drive  which has  been installed in the equipment  it is recommended that the following procedure be  followed  A typical hi pot test setup is shown in Figure 12  on page 25     Note  All equipment AC line inputs must be disconnected from the AC power     CAUTION  To avoid damage to the arive  do not connect any terminals of  Terminal Block       to the hi pot tester     A  Connect all equipment AC power input lines together and connect them to the  H V  lead of the hi pot tester  Connect the RETURN lead of the hi pot tester to  the frame on which the control and other auxiliary equipment are mounted     B  The hi pot tester must have an automatic ramp up to the test voltage and an  automatic ramp down to zero voltage     Note  If the hi pot tester does not have automatic ramping  then the hi pot out   put must be manually increased to the test voltage and then manually reduced  to zero  This procedure must be followed for each machine to be tested     sug   gested hi pot tester is Slaughter Model 2550     WARNING  Instantaneously applying the hi pot voltage will cause irre   versible damage to the drive     DRIVE OPERATION  Before operating the drive  read the following instructions on keypad use and pro   gramming functions  See Figure 13  on page 27  for the digital keypad layout     Note  To prevent damage  do not operat
63. puts     Provides selection of Stop  Reset  Jog  and up to  3 Preset Speeds     External Forward Stop Reverse Control   Provides external control of motor direc   tion and run stop  Forward Stop  Reverse Stop or Run Stop  Forward Reverse      Isolated External Signal Inputs     Provides isolated terminals for an external signal  to control output frequency  potentiometer  5k 10k   O   10 VDC  0   20 mADC   4   20 mADC      Multifunction Output Relay     Provides normally open relay contacts for indication  of Run  Frequency Reached  or Fault     Output Frequency Upper Limit     Provides adjustment of output frequency upper  limit  1 0   200 Hz    7    Sec      Introduction  Cont         Output Frequency Lower Limit     Provides adjustment of output frequency lower  limit  0 0   200 Hz     Acceleration and Deceleration Time     Provides adjustment of acceleration and  deceleration time  0 1   999 seconds      Operates 60 Hz and 50 Hz Motors     Provides tailoring of the drive for 60 Hz or 50  Hz motors  factory set for 60 Hz motors      Analog Output Voltage     Provides connections for an analog voltage  0   10 V DC   proportional to the output frequency     Preset Volts Hz Curves with Program Modification     Used to tailor the drive for  constant torque  high starting torque  or variable torque  HVAC  applications     Approvals   UL Listed  USA and Canada   CE             N10980   ISO 9002     PROTECTION FEATURES  Fault Codes are Displayed   See Table 17  on pages 49 and 50
64. res Page  5B  External Start Stop Forward Reverse Open Collector Connections           20  6A  SW1 Set for Remote Speed Potentiometer or Voltage Following Signal Input   21  6B  SW1 Set for Current Following                                                    21  7  Remote Speed Potentiometer Connection                             21  8  Voltage Following Connection                                       22  9   Gurrent Following  CONNECHON  es esas ye                                   ER 22  10A  Multifunction Input Terminal Connections                               23  108  Multifunction Input Terminal Open Collector Connections                  23  11  Multifunction Output Relay and Analog Output Voltage Connections          24  T9 ROU SOUS Liu             wagen ug iore                        Oe RSS          25  13  Digital Keypad Layout                                               27  14  Flow Chart to Change Set Frequency  Drive in Stop Mode                  29  15  Flow Chart to Program F01  Acceleration Time                           29  165  VoltS Elz  Pattern  acd eite renes der eor EY                 41  17  Volts Hz Curve Modification  Torque Boost                              43  18  Controlled Deceleration to Stop with DC Injection Braking                 44  19  Recommended RFI Filter Connection                                 52  20   DLMOCOnFISeO B uacccesede Sp er i qae Way pete      ab er 53    SIMPLIFIED INSTRUCTIONS    WARNING  These instructions are to be 
65. rily Displayed Acceleration Time  the New Setting which Confirms Function Number  New Setting is Displayed  V H     Gr    050          Press to Display  Set Frequency    Set Frequency  Flashes                    1    is displayed   29    30    Sec  VIII     Drive Operation  Cont             Press the                 key     05 0     5 0 seconds  will be displayed   factory setting         Press the    or W RESET key until the desired acceleration time is dis   played  Maintaining pressure on the    or W RESET key will cause the  display units to change rapidly  The programmable range is 0 1   999  seconds     e  Press the DATA ENT key to set the new acceleration time     FO1    will be  displayed        f  Press the DSP FUN key to return to the frequency display or press the  A or W RESET key to change to another function number     3  204  Motor Direction      F04 is factory set to  000   Forward Direction      The motor direction can be changed while the drive is in the Stop  Mode or Run Mode     a  Press the DSP FUN key to display function number    Press the    or W RESET key until    F04    is displayed   Press the DATAVENT key     000  will be displayed    Press the    or W RESET key until code    001    is displayed            0    Press the DATA ENT key to      the drive for reverse motor direction      F04    will be displayed     f  Press the DSP FUN key to return to the frequency display or press the  A or W RESET key to change to another function number           
66. se only AC line input models  Pkg  B and Pkg  C1   wire the AC line     Terminals L1  L2  L3  as shown in Figures      and 3C  on page 18     B  Ground Connection   As shown in Figures             and       on page 18     C  AC Line Fusing   Install a fuse or circuit breaker in the AC line  Fuse each con   ductor that is not at ground  earth  potential  See Section VI  on page 24  for  recommended ratings     D  Motor Connection     Connect the motor to Terminals T1 U   T2  V   T3  W  of  Terminal Block TM1  as shown in Figures 3A  3B  and 3C  on page 18  and as  described in Section IV C  on page 19  Motor cable length should not exceed  100 feet  30m  or special Load Reactors may be required     contact the Sales  Department  See Section X F  Table 22  on page 53           Note  This drive has been programmed to operate 60 Hz motors  For 50 Hz  motor operation  see Section VIII C and Table 11 on page 30     E  Power Up and Basic Keypad Operation   When applying power to the drive   the LED  located at the top left of the digital display will illuminate  The digital  display will flash the set frequency  factory setting is    05 0      To increase the fre   quency  press the A key until the desired frequency is displayed  To decrease  frequency  press the W RESET key until the desired frequency is displayed   Press the RUN STOP key to start the drive  See Section VIII  on page 26  5    SAFETY WARNING  Definition of Safety Warning Symbols        wM 4 Electrical Hazard Warning
67. ss A Industrial             Notes  1  Models KBE2 1125 P  1150     2150    2101    do not contain a braking transistor  2  Models KBE2   2202  2203  4301  4302  and 4303 require optional brake resistor to achieve maximum braking  Maximum brak     ing torque varies with model  3  Proportional to the Output Frequency Upper Limit set with   06     11    TABLE 3     MODEL NUMBER IDENTIFICATION    Sec        Introduction  Cont                                                                     2 1 oi   P F 5     Series           Input Input lorsepower Enclosure RFI          Switch  Voltage Phase 25 025 HP Type Filter Option Option   1 115  1 19 50  0 5 HP P  Panel F  With Filter S  With On Off  amp   2  230V 2 10  amp  36 1  1 HP Mount    20 Blank  Without     Forward Reverse Switch  4  460V 3 36 2  2 HP 4           4   IP 65     Filter Blank  Without Switch  3  3 HP Indoor      Available for    for Models                     NEMA 4 IP 65 Models Only     FIGURE 1A   MECHANICAL SPECIFICATIONS  Inches mm   BE2 1125 P  1150 P  1101     2125     2150     2101 P  Pkg  A                                                                                                        7    i     ERN  4 56  116  5 20  132  22222222222 Drive Depth is  4 65       299919   amp    L    3 1  x  N 0 18  2 40 mE          A 3  0 45  2 83    72    FIGURE 1B     MECHANICAL SPECIFICATIONS  Inches mm   for Models KBE2 2202 P  2203 P  4301 P  4302 P  4303 P  Pkg  B                                                 
68. start and stop the  drive  However these circuits are never to be used as safety disconnects since they are  not fail safe  Use only the AC line for this purpose     Be sure to follow all instructions carefully  Fire and or electrocution can result due to  improper use of this product              This product complies with all CE directives pertinent at the time of manufac   ture  Contact the Sales Department for Declaration of Conformity        INTRODUCTION   Thank you for purchasing the GENESIS   KBE2 Series Inverter  KB Electronics  Inc   is committed to providing total customer satisfaction by providing quality products  that are easy to install and operate     The KBE2 is available in IP 20 Panel Mount and          4   IP 65  indoor  enclosures   They operate 3 phase AC induction motors thru 3 HP  Several models are available  with 115  208 230  and 380 460 Volts AC   50 60 Hz AC line input  They contain a  3 digit LED display with a digital keypad for simplified programming  Although very  compact  the KBE2 contains many user friendly features found in more costly drives           Sec        Introduction  Cont         These include regenerative and DC injection braking  auto manual restart  Volts Hz  curve selection  selectable switching frequency  adjustable acceleration and decel   eration  and 0   200 Hz operation     An isolated multifunction terminal block provides for external control of start stop   forward reverse  and analog input signal following  Other funct
69. tening Torque  Multifunction Input Terminal Description AWG mm  in lbs   kg cm       vera Une All Signal Inputs and Outputs  maximum allowable  Terminals 1   11  24 18   02 0 8 5 6    load current for  Terminal  5  is 20  mA DC  3  All terminals of Terminal Block       are isolated from the AC line and  motor wiring  This eliminates the need for an isolated input signal                          19    20    Sec         Term  Block TM2 Wiring Inst   Cont               A  External FIGURE 5A   EXTERNAL FIGURE 5B     EXTERNAL  Start Stop  START STOP FORWARD  START STOP FORWARD   REVERSE CONNECTIONS REVERSE OPEN COLLECTOR  plate ag a CONNECTIONS  onneton  S      REV 412  External control of 3 4 5 FWO REV  12    Start Stop and 3 4 5  Forward Reverse 5   is achieved by  wiring contacts to FWD  Terminals 3  4  and REV  5  as shown in  Figure 5A  To program the drive for external  Start Stop  set F10  Start Stop Control  to    O01     External Contacts   as described in Section IX  on page 42                       The drive is factory programmed to operate Forward Stop using Terminal 3 and  Reverse Stop using Terminal 4  To program the drive to operate Run Stop using  Terminal    and Forward Reverse using Terminal 4  set        to    001     Run Stop   Forward Reverse   The settings for external Start Stop control using         External Forward Stop Reverse Control  are shown in Table 6           WARNING  The Stop contact is never to be used as a Safety      Disconnect since it is not 
70. the latest fault  that occurred     xx x    indicates the previous fault that occurred     xxx     indicates  the first fault that occurred   Press the W RESET key to erase all three recorded  faults                         and          will be displayed when the key is pressed   See    Table 17  on pages 49 and 50        X  OPTIONAL ACCESSORIES  A  DIN Rail Mounting Kit  Part No  14000    Available for all models except  KBE2 1125 4  1150 4  1101 4  2101 4  2202 4  2203 4  4301 4  4302 4   4308 4     B  Class B Residential Standard RFI  EMI  Filters     Provides RFI noise suppres   sion and complies with CE Directive 89 336 EEC relating to the EMC Class B  Residential Standard  See Table 19 and Figure 19  on page 52  The recom   mended maximum wiring distance between drive and filter is 12   30 cm      TABLE 19   CLASS B RESIDENTIAL STANDARD RFI FILTERS    Dimensions       Part  No        Rating Drive Model ime  nches mm       14020   10 Amps   230 Volts AC    1     All 230 Volt AC thru 1       2 99  6 14  0 98  76x156x25       14012   20 Amps   230 Volts          1          230 Volt AC thru 3 HP 4 84x6 81x1 54  123x173x39  14015   10 Amps   460 Volts AC            All 380 460 Volt AC thru 3 HP   4 84x6 81x1 54  123x173x39                      Note  All models are available with a built in Class A Industrial Standard RFI Filter  Contact Sales Department   51       Sec  X     Optional Accessories  Cont         FIGURE 19   RECOMMENDED PFI FILTER CONNECTION         Cable Shield
71. used as a guide only after reading  the complete instructions contained herein     Important Application Information  It is recommended that this drive be used with  Inverter Duty or TENV motors which provide full rated torque over an extended  speed range without overheating  If external fan cooling is provided  open ventilat   ed motors can also achieve an extended speed range at full rated torque  A box fan  or blower with a minimum of 100 CFM is recommended  Mount the fan so that the  motor is surrounded by the airflow     Some motors have low speed characteristics which cause overheating and winding  failure under light or no load conditions  If the motor is operated in this manner for  an extended period of time  it is recommended that the unloaded motor current be  checked from 2   15 Hz  60   450 RPM  to ensure that the motor current does not  exceed the nameplate rating  Do not use motor if the motor current exceeds the  nameplate rating        ES      4 WARNING  Disconnect the main power when making connections         to the drive              Note  See Section         Reconditioning Bus Capacitors on page 15     A  AC Line Connection    1  For single phase only AC line input models  Pkg  A and Pkg  C   wire the AC  ine to Terminals L1  L2  as shown in Figure 3A  on page 18     2  For dual phase  1         AC line input models  Pkg     and Pkg  C1   wire the  1 according to Figures 3B and 3C  on page 18  Wire the 3p AC line to  Terminals L1  L2  L3     3  For 3 Pha
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
LevelOne WAP-6102 WLAN access point  MANUAL DEL USUARIO - Icon Heath & Fitness  UNO WEB Manual de Usuario V2  MANO872 VA1 User`s Manual  guia do produto  Hanns.G HX171 User's Manual  【写真入り】取扱説明書 営繕工事用  CM 210  ADEMCO LYNXR-IE Security Systems Installation and Setup Guide  инструкцию для Pioneer DEH    Copyright © All rights reserved. 