1 Installation 1.1 Operating System SCO UNIX System V
Contents
1. Which eiad SCSI host adapter supports this device Select 0 1 or q to quit 0 lt RETURN gt What is the Target ID for this device Select 0 7 or h for help or q to quit 3 lt RETURN gt What is the LUN of this device Press RETURN to use the default 0 Select 0 7 or h for help or q to quit 0 lt RETURN gt You will be warned that the contents or components thereof will be erased during the installation During installation you may choose to overwrite all or part of the present contents of your hard disk Do you wish to continue y n Continue with y E y lt RETURN gt The partitioning program etc fdisk is invoked atthis point Ifyou terminate it with q then the installation procedure for the MOD is continued Enter lt DEL gt if you wish to abort the complete MOD installation The hard disk installation program will now invoke etc fdisk Entering q at the following menu will exit etc fdisk and the hard disk installation will continue If you wish to exit the entire installation at this menu press the lt Del gt key The fdisk menu appears Display Partition Table Use Entire Disk for UNIX Use Rest of Disk for UNIX Create UNIX Partition Activate Partition Delete Partition Aaa E 9 16 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Enter your choice or q to quit Enter 2 to utilize the complete MOD as a UNIX partition E 2 lt RETURN gt Curr
2. install lt RETURN gt The installation menu is displayed Invokei nit The copy is subsequently ready for operation 9 54 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation The printer settings are transferred during the copying process Ifyou have configured your printer before copying is started then itis also set for the copy of the STRUC G master Invoke the item pri nt in the installation menu to alter the STRUC G printer set up 1 5 2 3 Print Configure Printer STRUC G transfers its print jobs to the operating system You must declare the printer installed in the operating system to STRUC G and specify the type of printer STRUC G can generate function drawings in postscriptand CGM format A postscript test file can be printed on the operating system level to test a postscript printer Dl ipr o raw simadyn struc 423 1 nk_par test ps simadyn struc 42 is the workbench file of the STRUC machine installation The following printout is generated STRUC G Postscript Test File Diagram 1 7 Schematic Representation of the Postscript Test Printout Enter print in the installation menu to start the STRUC G printer configuration E print lt RETURN gt You will be subsequently prompted as to whether you want to transfer the printer configuration of another STRUC G system WORKBENCH DIRECTORY is Simadyn struc 423 Do you want to transfer the printer configuration of
3. D Display Hardware Configuration In order to display which drivers are present in the operating system kernel for various hardware components The steps described in this section are only necessary when you D wish to completely install the PC yourself D wish to re install the operating system D wish to install additional hardware or D wish to install additional drivers The following descriptions are intended as examples only It will depend upon the specific configuration of your computer as to whether differences are apparent If in doubt refer to the SCO operating system documentation SCO Open Systems Software Hardware Configuration Guide SCO Hardware Compatibility Handbook SCO Open Desktop SCO Open Server Installation and Upgrade Guide SCO Open Desktop SCO Open Server System Administrator s Guide Operating System Networking and DOS Services SCO Open Systems Software International Supplement You will require the root password and the addresses of the serial and parallel interfaces in order to successfully install the drivers the printer and adapt the operating system parameters Several of the steps to be implemented in the following will alter the operating system kernel The system must then be shut down and subsequently restarted after generating the new kernel in order to activate these modifications All system users should log off the system before operating system changes are made Sie
4. NOT USED no 4 NOT USED no 5 NOT USED no 6 d1157al l WHOLE DISK no 7 0 122863 t te eee eee t Se t 121855 blocks for divisions 1008 1K blocks reserved for the system 9 18 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation n ame Name or rename a division c reate Create a new file system on this division t ype Select or change file system type on new file systems pl revent Prevent a new file system from being created on this division s tart Start a division on a different block e nd End a division on a different block r estore Restore the original division table Enter your choice or q to quit Enterc to create a file system on the MOD E c lt RETURN gt which division 0 through 6 Enter 0 E 0 lt RETURN gt Enterq to exitthe next menu to be displayed You then have the choice to either create the file system as entered on the MOD to alter the set up or terminate the program without creating the file system Enteri ifnstall Install the division set up shown r eturn Return to the previous menu e xit Exit without installing a division table Please enter your choice i lt RETURN gt The file system is created It will take several minutes Making file systems Hard disk initialization procedure completed The MOD driver is then installed and an MOD can be loaded with a file system This type of MOD can be moun
5. Select Enable Enterps struc into the first entry panel and acknowledge with lt RETURN gt as often as it is necessary to complete the screen Press any key to return to the menu line Select Accept Enter ps struc into the first entry panel and acknowledge with lt RETURN gt as often as is necessary until the screen is completed Press any key to return to the menu line Press lt ESC gt as many times as is required to return to the menu line originally displayed when you started the program Select Quit gt Yes to exit the program A postscript test file can be printed out after the successful installation of STRUC G to testa postscript printer at the operating system level Bl ipr o raw struc Ink_par test ps struc is the root directory of your STRUC machine installation The following printout is generated STRUC G Postscript Test File Diagram 1 3 Schematic Representation of a Postscript Test Printout 1 1 8 Install a Driver for the SINEC CP1411 Board The installation of the software for the SINEC CP1411 board on SCO UNIX systems is described in the product information SOFTNET H1 TF UNIX for SCO 1 1 9 Adapting the Operating System Kernel Parameters Log in as root and bring the system into single user mode 9 22 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation H init 1 lt RETURN gt The parameters NPROC MAXUP and NREGION are to be modified Utilize the
6. Switch to this folder with a double click on the icon System Administration and start the tool Hardware Kernel Manager Click onthe location Serial Port inorderto enter the window for the installation ofthe serial interface Proceed in this window as follows Serial Board Initialization The following cards are currently configured 1 BM COM1 1 port card i o address 3f8 interrupt COMI i nstall a new serial board r emove an existing board q uit Please enter your choice i r q gt 9 32 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Enter i to install a further interface E i lt RETURN gt You would like to install a 1 1 port card 2 2 port card 3 4 port card 4 5 port card 5 8 port card 6 16 port card Enter your choice or q to quit Enter 1 to add one interface E 1 lt RETURN gt The card is configured as 1 COMI 2 COM2 3 COM3 4 COM4 Enter your choice or q to quit Enter 2 to select the second interface E 2 lt RETURN gt Which card do you have the following are supported 1 Quadram base address 0x288 2 BM COM2 base address 0x2f8 Enter your choice or q to quit Enter 2 for an IBM compatible interface E 2 lt RETURN gt Please enter the baud rate to be used on the modem devices In addition to the normal driver for a serial interface a driver is automatically generated via which a modem can be controlled The baud rate
7. add configure the high sierra file system y n In order to mount a CD ROM with file system you must reply with y at this point E y lt RETURN gt High Sierra 1809660 file system Configuration Program 1 Add High Sierra 1809660 file systemto system configuration 2 Remove High Sierra 1 09660 file system from system confi guration Select an option or enter q to quit D1 lt RETURN gt System configuration files have been successfully modified CD ROM Configuration Program 1 Install a CD ROM Drive 2 Remove a CD ROM Drive 3 Install a CD ROM TAPE Driver 4 Remove a CD ROM TAPE Driver Select an option or enter q to quit The name of the generated driver is dependent upon the number of the installed CD ROM drives The first drive is called dev cd0 the second dev cd1 etc Terminate the configuration with q E q lt RETURN gt You must create a new kernel to effect the driver change you specified Do you wish to create a new kernel now y n In order to activate these modifications re link the operating system kernel shut down and subsequently restart the operating system Link the kernel by entering y here and for all further prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y Backing up unix to unix old In
8. from Disks As opposed to other data carriers diskettes can represent a whole series of data carriers The diskettes are sequentially numbered Start loading with the first diskette When a diskette has completed loading then the following message will appear on the screen tar please insert new volume then press RETURN Insert the next disk and acknowledge with lt RETURN gt Loading then continues from the new diskette Ifa message does notappear after loading has completed from any particular diskette but rather the entry prompt then insert the next disk and repeat the t ar command For example E tar xvf dev rfd0135ds18 lt RETURN gt Continue this procedure until all the diskettes have been loaded During the loading procedure the loaded file names are displayed on the screen Loading the complete packet will take some time struc 423 conf STRUC_G obj d2 obj scr struc 423 conf picture px You have now completed loading the STRUC G packet All further installation steps are menu driven with an instal lation program A further directory is now located in the start directory si madyn and contains all the STRUC G data This directory can be reviewed with the command s E is lt RETURN gt struc 423 The directoryst ruc 423 is the rootdirectory of your machine installation It s complete path name in ourexample is Si madyn struc 42 3 This directory is known in the following as Workbench We will
9. may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y lt RETURN gt The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment The operating system kernel has been re linked Activate by shutting down and subsequently restarting the operating system H init 6 lt RETURN gt 9 10 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation 1 1 5 Installing a Driver fora CD ROM Drive This example assumes that the CD ROM drive has not yetbeen installed and thatit possesses an SCSI interface The system has an SCSI controller host adapter for which the operating system utilizes the abbreviation eiad this abbreviation is fixed by the operating system It is dependent upon the type of the SCSI controller A table containing these abbreviations can be found in the SCO Open Systems Software Hardware Configuration Guide contained in the chapter Introduction Configuring Devices atinstallation or boot time SC SI host adapter configuration on page 7 The SCSI controller is already installed The identification number of the CD ROM drive at the SCSI bus is 5 this value is already set or must be set on the drive itself A CD ROM can contain a file system These types of CD ROM s can be linked into the system as a hard disk read only In order to supportthis the following example
10. name ps_ struc The program sysadmsh is utilized to install the printer E sysadmsh lt RETURN gt This program displays a menu name in the upper right hand corner a menu line and the remainder of the display below this name is normally a screen for entering data Selecta menu item using the cursor keys and lt RETURN gt orenter the first letter of the menu item A selected menu item is highlighted A brief comment regarding this menu item appears below the menu line A screen is usually completed and your data processed by entering data in the last input panel and acknowledging with lt RETURN gt Allinputpanels in a screen mustnormally be processed in sequence Press lt ESC gt to abortthe screen and return to the next menu level After invoking s ys admsh and selecting the menu item pri nt ers the screen is as follows 9 20 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation SysAdmSh System Backups Accounts MEE Media Jobs Dirs Files File Systems User Quit Administer the print System Select the menu sequence Printers gt Configure gt Add to inserta new printer i e by entering the three characters p c and a Hpca Please make the following entries in the subsequently displayed screen Printer Name in the Panel Printer name E ps struc lt RETURN gt Circumvent Comment and Class name by pressing lt RETURN gt twice Printer Type in th
11. or q to quit Our MOD drive has the number 3 E 3 lt RETURN gt What is the LUN of this device Press lt Return gt to use the default 0 Select 0 7 or h for help or q to quit Usually the MOD controller and MOD drive are one constructive unit Therefore select 0 That is also the default E lt RETURN gt During installation you may choose to overwrite all or part of the present contents of your hard disk Do you which to continue y n Proceed at this point by entering y E y lt RETURN gt Invoke the partitioning program etc fdisk at this point If you terminate it with q then the installation procedure for the MOD is continued If you wish to abort the complete MOD installation then enter lt DEL gt The hard disk installation program will now invoke etc fdisk Entering gq at the following menu will exit etc fdisk and the hard disk installation will continue If you wish to exit the entire installation at this menu press the lt Del gt key Siemens AG 465 981 7101 23 Edition 02 96 9 39 SIMADYN D STRUC G User manual 9 Installation The fdisk menu now appears Display Partition Table Use Entire Disk for UNIX Use Rest of Disk for UNIX Create UNIX Partition Activate Partition Delete Partition Create Partition ieee eae Enter your choice or q to quit Enter 3 in order to utilize the complete MOD as an UNIX partition E 3 lt RETURN gt Warning Your UNIX partition is not on
12. shows how a directory is created in which the file system ofa CD ROM is Mounted the data on the CD ROM appears in this directory after mounting and the High Sierra File System is configured Log in as root and bring the system into single user mode E init 1 lt RETURN gt Create the directory for mounting a CD ROM H mkdir cdrom lt RETURN gt chmod 755 cdrom lt RETURN gt Install the CD ROM driver by invoking the program mkdev cdrom E mkdev cdrom CD ROM Configuration Program Install a CD ROM Drive Remove a CD ROM Drive Install a CD ROM TAPE Driver Remove a CD ROM TAPE Driver Wr Pe Select an option or enter q to quit Select 1 to add the drive D1 lt RETURN gt Updating system configuration System files have been successfully updated The CD ROM Driver must be configured before use Do you wish to configure the CD ROM Driver now y n Enter y E y lt RETURN gt Enter the prefix of the SCSI host adapter that supports this device or press lt Return gt for the default eiad Enter h for a list of host adapters or enter q to quit Siemens AG 465 981 7101 23 Edition 02 96 9 11 SIMADYN D STRUC G User manual 9 Installation We will use the default E lt RETURN gt Which eiad SCSI host adapter supports this device Select 0 1 or enter q to quit There is only one SCSI controller It possesses the number 0 the SCSI controllers present in the system are numbered s
13. system to single user mode E init 1 lt RETURN gt Utilize the program mkdev serial E mkdev serial Serial Board Initialization The following cards are currently configured 1 BM COM1 1 port card i o address 3f8 interrupt COMI i nstall a new serial board r emove an existing board q uit Please enter your choice i r q gt Enter i to install a further interface 9 8 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation E i lt RETURN gt You would like to install a 1 1 port card 2 2 port card 3 4 port card 4 5 port card 5 8 port card 6 16 port card Enter your choice or q to quit Enter 1 to add one interface E 1 lt RETURN gt The card is configured as 1 COMI 2 COM2 3 COM3 4 COM4 Enter your choice or q to quit Enter 2 to select the second interface E 2 lt RETURN gt Which card do you have the following are supported 1 Quadram base address 0x288 2 BM COM2 base address 0x2f 8 Enter your choice or q to quit Select 2 for an IBM compatible interface D2 lt RETURN gt Please enter the baud rate to be used on the modem devices In addition to the normal driver for a serial interface a driver is automatically generated through which a modem can be triggered via this interface Select the baud rate for this driver Therefore enter for example 9600 E 9600 lt RETURN gt The following etc gettydefs F entries support 960
14. vector 4 etc hwceonfig h does not interrogate the hardware in your PC You cannot obtain information regarding the hardware for which no driver has yet been installed Siemens AG 465 981 7101 23 Edition 02 96 9 47 SIMADYN D STRUC G User manual 9 Installation 1 5 Installation of the STRUC G Master This chapter describes the installation of the STRUC G packet on your PC The following text contains the terms STRUC G Master Master Installation and Machine Installation as synonyms They designate the loaded STRUC G packet On the other hand terms such as User Installation User Initialization are also utilized They designate the file structures created in a separate installation step by the user or the installation stage itself STRUC G is installed in several steps 1 Loading the packet from the data carrier 2 Machine initialization global set up The STRUC G packet is thereby installed on your computer The user must create the necessary user file directory structures in a further step before he can work with STRUC G 3 User initialization see chapter 9 3 Steps two and three utilize the installation program in STRUC G The machine initialization can be repeated at any time point The renewed machine initialization is necessary when for example a new printer is to be created in the STRUC G master installation or when errors have occurred during the first run To install log in as root Warning Iti
15. 0 baud lines 9600 console 9600H 0 6 m Sc_m oo UT SS W PF Choose one of the above entries or g to quit Siemens AG 465 981 7101 23 Edition 02 96 9 9 SIMADYN D STRUC G User manual 9 Installation Enter 1 for example E 1 lt RETURN gt Configuration files are altered You will be informed that two drivers are to be generated dev tty2a and dev tty2A dev tty2A can trigger modems Subsequently it will be necessary to re link the operating system kernel The operating system musttherefore be shutdown and subsequently restarted in order to activate these changes Modifying system files No terminals needed adding to the Terminal Control data base System files successfully updated The following standard serial device s have been installed tty2a The following device s access the same physical port as their lower case counterpart but have modem control properties tty2A You must create a new kernel to effect the driver change you specified Do you wish to create a new kernel now y n Reply with y to all further prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y lt RETURN gt Backing up unix to unix old Installing new unix The kernel environment includes device node files and etc inittab The new kernel
16. 9 Installation 1 installation This chapter describes the installation of the necessary drivers the installation of printers the adaptation of several parameters in the operating system kernel as well as the configuration of the keyboard with the German keyboard layout Italso explains how you can display the drivers installed in the operating system Whereby the SCO operating system versions SCO UNIX System V 386 Release 3 2 and Open Server TM Release 5 are also considered 1 1 Operating System SCO UNIX System V 386 Release 3 2 You require the items described in this chapter for the following reasons D Driver for A parallel interface For the connection of a printer with a parallel interface A serial interface For the connection of a SIMADYN D rack in COM G graphics commissioning service with the function drawing editor A CD ROM Drive When you possess a CD ROM drive and STRUC G is supplied on a CD An MOD Drive f When you possess an MOD drive and STRUC G is supplied on an MOD Magneto Optical Disk D Printer Installation In order to access the printer from the operating system STRUC G transmits all print jobs to the operating system D Operating System Kernel Parameters To raise the number of simultaneously running tasks to a level required by STRUC G D Configure the Keyboard To setthe operating system to a keyboard with German layout of course only when you possess such a keyboard
17. DYN D STRUC G User manual 9 Installation fee eee eee tee eee eee ee te i tee eee eee ee Name Type New FS First Block Last Block fe e eee eee tees eee eee te i tee eee ee eee d1150 NOT USED no 0 0 121854 NOT USED no 1 NOT USED no 2 NOT USED no 3 NOT USED no 4 NOT USED no 5 NOT USED no 6 d1157al WHOLE DISK no 7 0 122863 fe eee ee ee f eee eee te i eenen tee eee ee eee 121855 blocks for divisions 1008 1K blocks reserved for the system n ame Name or rename a division c reate Create a new file system on this division tl ype Select or change file systemtype on new file systems p revent Prevent a new file system from being created on this division s tart Start a division on a different block e nd End a division on a different block r estore Restore the original division table Enter your choice or q to quit Enter n to define a name E n lt RETURN gt which division 0 through 7 Enter 0 E 0 lt RETURN gt what do you want to call it Enter mod for example E mod lt RETURN gt A table reappears Current Hard Disk Drive dev rdsk 1s50 to te cree eee t t o Hecron te 2 2 e Name Type New FS First Block Last Block t o t 55 t t fee eee eee te 22 22 eee d1150 NOT USED no 0 0 121854 NOT USED no 1 NOT USED no 2 NOT USED no 3
18. G is supplied on MOD D Printer Installation In order to access a printer via the operating system STRUC G transmits all print jobs to the operating system D Operating System Kernel Parameter In order to increase the number of simultaneously running processes to a level required by STRUCG D Configure Keyboard In order to set the operating system to a keyboard with German layout of course only when you possess this type of keyboard D Display Hardware Configuration In order to display which drivers are available in the operating system kernel for diverse hardware components The steps described in this chapter are only necessary when you D wish to completely install the PC yourself D wish to re install the operating system D wish to install additional hardware or D wish to install additional drivers The following descriptions are intended as examples only Any differences you may encounter depend upon your particular computer configuration If in doubt review the documentation of the SCO Operating System You will require the root password and the addresses of theirserial and parallel interfaces to successfully install the driver the printer and to adapt the operating system parameters Several of the steps to be implemented in the following will modify the operating system kernel The system after generation of a new kernel must be shut down and subsequently restarted in order to activate these modifications All users mus
19. IMADYN D STRUC G User manual
20. Ink_awd The data in Ink_awd is structured in projects and the projects are structured in master programs A particular project or master program has it s specific data ina directory that carries the name of the project master program Temporary files are located in the directory Ink_tmp the user can hold his own internal graphics libraries in Ink_igr configuration files for the COM G graphical commissioning service with the function drawing editor are located in Ink_onl and ver contains the block libraries and other system files A practice example project pjv400 master program handmp is located in Ink_awd after the installation is completed 1 6 1 Initializing the User Data Invoke the installation program in order to create the user structure described above Log in as user Switch to the sub directory i nst al ofthe machine installation workbench directory i e simadyn struc 42 install Ecd simadyn struc 42 install lt RETURN gt Invoke the installation program EQ install lt RETURN gt The user name and group are displayed init_user ush Initialization of the user working area for STRUC G gt gt USER bern lt lt gt gt GROUP struc lt lt 9 66 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation gt gt HOME scousr00 bern lt lt Initialization for the user bern group struc Working area Scousr00 bern Do you wish to continue y yes default n n
21. Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y Backing up unix to unix old Installing new unix The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment After the Systemis rebooted with the new kernel reinvoke mkdev hd to initialize the new SCSI hard disk The operating system kernel is re linked Activate by shutting down and subsequently restarting the operating system H init 6 lt RETURN gt Siemens AG 465 981 7101 23 Edition 02 96 9 15 SIMADYN D STRUC G User manual 9 Installation mkdev hd must now be invoked for the second time Insert the MOD into the drive E mkdev hd lt RETURN gt Your root disk is attached to a SCSI controller The only available choice is to add another SCSI disk Do you want to add another SCSI disk Acknowledge with y E y lt RETURN gt You will now be prompted to re enter the SCSI Controller Type Controller Target ID and LUN Utilize the same values as above Enter the prefix of the SCSI host adapter that supports this device or press lt RETURN gt for the default eiad Enter h for a list of host adapters or enter q to quit eiad lt RETURN gt
22. a cylinder boundary You may want to place it on a cylinder boundary to accommodate other systems Starting at track 64 and using a size of 7552 tracks will place your partition on a cylinder boundary Current Hard Disk Drive dev rdsk 1s50 tose rere ee tees e eee teers H Partition Status Type Start End Size teers cress tees ee eeee teers a e t 1 Inaktive UNIX 1 7679 7679 frie snore we prin es ens pire partes pees pense Total disk size 7744 tracks 65 reserved for masterboot and diagnostics Press lt Return gt to continue The MOD can be accessed via dev rdsk 1s0 the first line above the table In your particular case another name could appear This is dependent upon the number of previously installed hard disks Note the name The STRUC software which could possibly be supplied ona MOD is therefore loaded via this name Enter lt RETURN gt to continue E lt RETURN gt The fdisk menu now appears Display Partition Table Use Entire Disk for UNIX Use Rest of Disk for UNIX Create UNIX Partition Activate Partition Delete Partition Create Partition meee E Enter your choice or q to quit Now enter 5 in order to activate the created partition D5 lt Return gt You will now be prompted to define which partition is to be active Enter the number of your partition 9 40 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation The fdisk
23. a previously installed STRUC G system y yes default n no Siemens AG 465 981 7101 23 Edition 02 96 9 55 SIMADYN D STRUC G User manual 9 Installation Entern to configure the printerand y or lt RETURN gt to transfer the configuration even when you transfer the printer configuration it can be immediately expanded or modified Attention For the first installation of STRUC G with SCO UNIX 5 0 you can t transfer the printer configura tion of SCO UNIX 3 2 Create Printer Configuration init_print ush Initialization of the printer plotter for STRUC G In order for STRUC G users to utilize the available plotters it is necessary to generate a list containing specific information regarding these printers plotters The printer menu is created fromthis information An example list is popped on to screen to clarify Remarks prerequisites Each panel must be assigned Further information can be obtained fromthe Installation Guide Continue with lt RETURN gt get _print ush gt Acknowledge with lt RETURN gt You will then receive an overview of the information to be specified for each printer You must specify a printer number a printer name a comment and a printer type for every printer The printer number is utilized for the internal management ofthe printerin STRUC G The printer name is the name received by the printer during the printer initialization at the operating system level in section 8 1 7 the printer ps_struc
24. allation type install gt You have therefore completed the printer configuration Save Printer Configuration Attention For the first installation of STRUC G with SCO UNIX 5 0 you can t transfer the printer configura tion of SCO UNIX 3 2 If the reply is yes to the prompt of whether the printer configuration of a previously installed system should be transferred then you will be initially prompted for the complete path name of the system from which itis to be transferred Please enter the complete path name of the STRUC G system from which you want to utilize the configuration Enter the path i e simadyn struc 42 o0ld E simadyn struc 42 old lt RETURN gt You will be displayed the list of the printers configured at this location and prompted as to whether you wish to transfer this configuration Printer Printer Comment Printer Number Name Type Siemens AG 465 981 7101 23 Edition 02 96 9 59 SIMADYN D STRUC G User manual 9 Installation 0 DEC2150 DEC Laser at B36 PSA4P 9 wdv CGM printer at A34 CGM Do you want to accept this configuration y yes default n no Enterno to discard this configuration Acknowledge with lt RETURN gt to transfer E lt RETURN gt You will then be prompted as to whether you wish to expand this configuration A reply with no terminates the printer configuration Continue in section 9 2 2 3 Create Printer Configuration if the reply is yes Do you want to expand the printe
25. an be Mounted the CD ROM s data appears in this directory after mounting and the High Sierra File System can be configured Log in as root and open a UNIX window with a double click on the UNIX icon Switch the computer into single user mode H init 1 lt RETURN gt Create the directory for mounting a CD ROM H mkdir cdrom lt RETURN gt chmod 755 cdrom lt RETURN gt Switch to this folder with a double click on the icon System Administration and start the tool Hardware Kernel Manager Click on the location CD ROM and WORM in order to enter the window for the installation of the CD ROM drives Proceed in this window as follows CD ROM Configuration Program 1 Install a CD ROM Drive 2 Remove a CD ROM Drive 3 Install a CD ROM TAPE Driver 4 Remove a CD ROM TAPE Driver Select an option or enter q to quit Add a drive by selecting 1 E 1 lt RETURN gt The CD ROM Driver must be configured before use Do you wish to configure the CD ROM Driver now y n Enter y E y lt RETURN gt Enter the prefix of the SCSI host adapter that supports this device or press lt Return gt for the default eiad Enter h for a list of host adapters or enter q to quit Siemens AG 465 981 7101 23 Edition 02 96 9 35 SIMADYN D STRUC G User manual 9 Installation We will utilize the default E lt RETURN gt Which eiad SCSI host adapter supports this device Select 0 1 or enter q to quit Only one SCSI
26. an option or enter q to quit D1 lt RETURN gt System configuration files have been successfully modified CD ROM Configuration Program 1 Install a CD ROM Drive 2 Remove a CD ROM Drive 3 Install a CD ROM TAPE Driver 4 Remove a CD ROM TAPE Driver Select an option or enter q to quit The name of the generated driver is dependent upon the number of installed CD ROM drives The first drive is known as dev cd0 the second dev cd1 etc Terminate configuring with q E q lt RETURN gt You must create a new kernel to effect the driver change you specified Do you wish to create a new kernel now y n In order to activate any alterations the operating system kernel must be re linked and the operating system shut down and subsequently restarted Link the kernel by entering y here and for all further prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y Backing up unix to unix old Installing new unix The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Siem
27. ation Now double click on the icon International Settings Manager Select the entry ps i bm ger in the column keyboard Also selectGerman_Germany in the anguage column The modifications become active when the operating system is shut down and subsequently restarted H init 6 lt RETURN gt Siemens AG 465 981 7101 23 Edition 02 96 9 45 SIMADYN D STRUC G User manual 9 Installation 1 3 STRUC G on Notebooks If STRUC G is installed in a SCO PC which is not configured in the Ethernet interface or also does not exist physically with Auto Detection Mode no Ethernet interface or no cable slotted by networks cards with Auto Detection Mode i e 3 COM Ether Link III then the function IBS G cannot be used Network cards with Auto Detection Mode must be installed without this mode to permit the utilization of IBS G with and without slotted cable The problem of using IBS G with or without slotted cable can be avoided by invoking the STRUC G scripts eth_on_off This scriptremoves the Ethernetinterface with the firstinvocation from the SCO configuration file The Ethernet interface will be inserted at the second invocation This problem mostly refers to STRUC G notebooks which are used in an office and on site as Stand Alone only In this case the scriptmustbe invoked before you remove notebooks from the docking station to prepare forstand alone operation At the end of stand alone operation the script must be invoked again to prepare
28. ault simadyn struc install gt Enter the complete path of the workbench as the destination for the STRUC G master an example is the path simadyn struc neu E simadyn struc neu lt RETURN gt Siemens AG 465 981 7101 23 Edition 02 96 9 53 SIMADYN D STRUC G User manual 9 Installation MAKE DIR Simadyn struc neu conf MAKE DIR sSimadyn struc neu conf STRUC G obj MAKE DIR Simadyn struc neu fonts MAKE DIR Simadyn struc neu xdef COPY FILE simadyn struc neu conf struc 42 G obj d2 objscr COPY FILE simadyn struc neu conf STRUC_G obj picture px COPY FILE simadyn struc neu xdef STRUC_G SW Copy the printer plotter menu files A machine initialization must be implemented for the destination workbench after the copy is made STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt Prior to the display of the installation menu you will be informed thatthe newly created STRUC G master requires the implementation of a machine installation Therefore switch to the workbench directory of the copy si madyn struc neu as shown above and invoke the installation program H cd simadyn struc neu lt RETURN gt cd install lt RETURN gt
29. been used then rename the directory i e to struc We will assume in the following that the root directory of your old version is called struc the complete path name is simadyn struc Switch to the directory si madyn Youcan now load the packet with the command tar see following section E cd simadyn lt RETURN gt Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation The STRUC G packet is loaded into the directory simadyn struc 42 During the installation you will be prompted for whether you wish to retain the printer set up froma previously installed STRUC G system You can transfer the set up from simadyn struc and then the older version ofs t ruc can be erased after completion of the installation of your new master Em rf simadyn struc lt RETURN gt When you have loaded a new STRUC G version then every user must implement a user initialization in order to update certain data from the machine installation 1 5 1 Loading from the Data Carrier In order to load the STRUC G packet you must have access to one of the following drives 3 5 inch disk drive Streamer tape drive CD ROM drive MOD drive Create the directory into which the STRUC G files are to be loaded We recommend that you create a separate directory in the root directory of your PC for all SIMADYN D related data The name of the root directory must correspond to DOS conventions maximum eight
30. ch the computer into single user mode H init 1 lt RETURN gt The parameters NPROC and NREGION are to be modified Use the program etc conf bin idtune to modify the operating system parameters The parameter NPROC is processed first It defines the maximum number of processes This parameter mustbe increased from 50 to 300 E etc conf bin idtune NPROC 300 lt RETURN gt Now modify the parameter NREGION number of regions allocated This is implemented in the same manner as with NPROC The value is increased from 300 to 945 E etc conf bin idtune NREGI ON 945 lt RETURN gt A new operating system kernel must now be linked in order to activate your modifications and to set this as the current operating system kernel Switch to this folder with a double click on the iconSystem Administration and click on the iconHardware Kernel Manager A window will be opened Click on the Rel ink Kernel in this window A new kernel is then linked Reply with y to all prompts The operating system must be shut down and subsequently restarted in order to activate the new kernel see Chapter LEERER MERKER H init 6 lt RETURN gt 1 2 10 Configure German Keyboard The configuration of a PS2 keyboard with German key layout is described here Log in as root and open an UNIX window with a double click on the UNIX icon Switch the computer into single user mode H init 1 lt RETURN gt Log in as root and double click on the icon System Administr
31. characters an optional dot a further three optional characters only use lower case characters do not use any of the characters or _ in the directory names ai mkdir sSimadyn lt RETURN gt chown root simadyn lt RETURN gt chmod 775 simadyn lt RETURN gt cd simadyn lt RETURN gt Insert the data carrier into the drive Load the data using the command t ar as follows E tar xvf lt dev gt lt RETURN gt lt dev gt is the name of the drive or its driver Examples for drive names dev rct0 Streamer tape dev rfd0135ds18 3 5 inch diskette 1 44 MB dev cd0 CD ROM dev rdsk 1s0 MOD The names of the drivers for the specified drives are dependentupon the number of available drives per type The example shows the drivers for the first 3 5 inch disk drive the first CD ROM drive and the first streamer tape drive the driver for a second 3 5 inch disk drive and a second CD ROM drive would be named dev rf d0135ds18 and dev cdl The magneto optical drive are handled as hard drives and therefore the MOD driver name is dependent upon the number of hard drives installed in frontofthe MOD drive The example shows that the MOD was the second Hard Drive with SCSI interface The name of the MOD driver is specified during the installation of the MOD drive see chapter 9 1 6 Siemens AG 465 981 7101 23 Edition 02 96 9 49 SIMADYN D STRUC G User manual 9 Installation Remarks for Loading
32. clicking the icon UNI X opens a window forthe entry of commands as shown in the lower right hand corner of diagram 2 2 Siemens AG 465 981 7101 23 Edition 02 96 9 5 SIMADYN D STRUC G User manual 9 Installation File Edit View Root s Directory ccessori Applications Diagram 1 2 The Graphics Console after Logging in as root The following display appears on an alpha numeric console the system name set during the operating system installation appears instead ofscosysv SCOSYySV Welcome to SCO Open Desktop Release 3 0 scosysv login You will be prompted for the entry of the password after entering the user name r oot Password Several operating system messages will appear after entering the password Last successful login for root Last unsuccessful login for root SCO UNIX System V 386 Release 3 2 Copyright C 1976 1990 Unix System Laboratories Inc Copyright C 1980 1989 Microsoft Corporation Copyright C 1983 1993 The Santa Cruz Operation Inc All Rights Reserved SCOSYSV Welcome to SCO Open Desktop Release 3 0 From The Santa Cruz Operation Inc 9 6 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manua 9 Installation The system is ready for commands when the appears 1 1 3 Ins
33. controller is available It possesses the number 0 the SCSI controllers available in the system are numbered in sequence beginning with 0 E 0 lt RETURN gt The Host Adapter parameters will be automatically configured What SCSI bus is this device attached to Press lt Return gt to use the default 0 Select O n or h for help or q to quit We will utilize the default E lt RETURN gt What is the Target ID for this device Select 0 15 or h for help or q to quit The drive has the number 5 E 5 lt RETURN gt What is the LUN for this device Press lt Return gt to use the default 0 Select 0 7 or h for help or q to quit Usually the controller forthe CD ROM and the CD ROM drive are one constructive unit Select 0 in this case This is also the default setting We will utilize the default E lt RETURN gt you are about to add the following SCSI device Host Adapter Adapter Type Device Number D LUN BUS eiad Srom 0 5 0 0 Update SCSI configuration y n Acknowledge with E y lt RETURN gt The SCSI configuration file has been updated Do you want to configure a CD ROM TAPE installation device y n Entering y causes the installation of the SCO software from CD to be supported You do not have to enter y to utilize the CD ROM drive Therefore enter either y orn E n lt RETURN gt 9 36 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Do you want to
34. e E settings Control All three switches must be switched on These switches must be switched off in order to suppress the output of a banner sheet at each printout E Settings Advanced Banners Enter 0 at this point for no banner If this printer is to be utilized as the standard default printer then this must be made known to the system Select the new default printer by using the mouse and implementing the following actions E Printer Set to Default 1 2 7 3 Test Printon a Postscript Printer A postscripttestfile can be printed outon the postscript printer as a test after successfully installing STRUC G Log into the system Open a UNIX window with a double click on the UNIX icon Then enter the following command line into this window H ipr d ps_struc o raw struc Ink_par test ps I struc is the root directory of your STRUC machine installation The following printout is generated STRUC G Postscript Test File Diagram 1 6 Schematic Representation of a Postscript Test Printout 9 44 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation 1 2 8 Install a Driver for the SINEC CP1411 Board The installation of the software for the SINEC CP1411 board on SCO UNIX systems is described in the product information SOFTNET H1 TF UNIX for SCO 1 2 9 Adapting the Operating System Kernel Parameters Log in as root and open an UNIX window with a double click on the UNIX icon Swit
35. e Panels Use Printer Interface Name of Interface SelectExi sting and acknowledge with lt RETURN gt Enterpostscript lt RETURN gt in the name of interface How the Printer is Connected in the Panels Connection Device Name Device SelectConnection Direct Enter dev lp0 lt RETURN gt inDevice Name SelectHardwi red in Device Generating a Banner Page in the Panel Require Banner Since each sheetofa function drawing is handled as an individual printjob itis notpracticalto generate banner pages Select No Entering lt RETURN gt completes the screen and the printer is installed The completed screen has the following appearance Printer name ps struc Comment Class name Use printer interface Existing Copy New Name of interface postscript Connection Direct Call up Device name dev 1p0 Device Hardwired Login Require banner Yes No Press any key to continue when requested to return to the menu To set the standard printer select the menu item default H a Enterdesti nation ps_struc lt RETURN gt inthe displayed screen Destination ps_struc Siemens AG 465 981 7101 23 Edition 02 96 9 21 SIMADYN D STRUC G User manual 9 Installation Press any key to return to the menu Press lt ESC gt to return to the Printers Menu SelectSchedule gt Begin SelectProceed and acknowledge with lt RETURN gt in the displayed screen Press any key to return you to the Printers Menu
36. ens AG 465 981 7101 23 Edition 02 96 9 13 SIMADYN D STRUC G User manual 9 Installation The operating system kernel is then re linked Activate by shutting down and then restarting the operating system DQ init 6 lt RETURN gt 1 1 6 Installing a Driver for an MOD Drive This example describes the installation of an MOD drive with SCSI interface The SCSI controller is already installed The operating system utilizes the designation eiad for the SCSI controller The installation of a magneto optical disk is implemented in principle the same way as the installation of a hard disk The program mkdev hd is utilized Therefore the outputs from mk dev hd will often carry the terms har d disk hard disk installation etc The identification number Target ID of the MOD drive at the SCSI bus is 3 The mkdev hd must be invoked twice for the installation of an MOD with SCSI interface The operating system kernel must be re linked the operating system shut down and then restarted subsequent to the first invocation The second mkdev hd holds an MOD ready for operation whose data can be erased Log in as root and bring the system into single user mode E init 1 lt RETURN gt E mkdev hd Your root disk is attached to a SCSI controller The only available choice is to add another SCSI disk Do you want to add another SCSI disk Reply with y E y lt RETURN gt Enter the prefix of the SCSI host adapter that supports thi
37. ent Hard Disk Drive dev rdsk 1s50 toss e eee t t t t t Partition Status Type Start End Size eessen t t ee t 1 Active UNIX 1 7679 7679 frst r eres Hersens t fesse teo t Total disk size 7744 tracks 65 reserved for master boot and diagnostics Press Return to continue The MOD can be accessed via dev rdsk 150 first line above the table A different name may also appear in your dialog Itis dependent upon the number of previously installed hard disks Please make a note of the name The STRUC software which could possibly be supplied on the MOD is therefore loaded via this name Enter lt RETURN gt to continue E lt RETURN gt You will be prompted for the number of file systems to be created on the partition There are 121855 blocks in the Unix area Please enter the number of file systems you want this area to be divided into or press lt RETURN gt to get the default of 1 file system s Enter lt RETURN gt for the default of 1 E lt RETURN gt The layout of the file systems and swap area is now prepared Do you wish to make any manual adjustments to the size or names of the file systems or swap area before they are created on the hard disk y n Enter y E y lt RETURN gt A table appears displaying the MOD distribution and a menu Current Hard Disk Drive dev rdsk 1s50 Siemens AG 465 981 7101 23 Edition 02 96 9 17 SIMA
38. entering root lt RETURN gt the password and lt RETURN gt The following display appears on an alpha numeric console the system name set during the operating system installation appears on screen instead ofs cos ys v the currentconsole name here console 3 appears instead of tty03 SCO Open Server TM Release 5 scosysv tty03 login You will be prompted to enter the password after entering the usernamer oot Password Several messages from the operating system will appear after entering the password SCO Open Server TM Release 5 1983 1993 The Santa Cruz Operation Inc 1980 1989 Microsoft Corporation 1976 1990 Unix System Laboratories Inc 1983 1993 The Santa Cruz Operation Inc All Rights reserved CECCI The system is ready to receive commands when the symbol appears The graphical path is described in the following 9 30 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation 1 2 3 Installing a Driver for a Parallel Interface This example assumes that the parallel interface utilizes the address range 278 27a and that no driver for a parallel interface was previously installed on the computer Log in as root and open a UNIX window with a double click on the UNIX icon Switch the computer into single user mode init 1 Switch to this folder with a double click on the System Administration icon and start the tool Hardware Kernel Manager Click on the locat
39. equentially beginning with 0 E 0 lt RETURN gt What is the Target ID for this device Select 0 7 or h for help or q to quit The drive has the number 5 E 5 lt RETURN gt What is the LUN for this device Press lt Return gt to use the default 0 Select 0 7 or h for help or q to quit The CD ROM controller and the CD ROM drive are normally one single constructive unit Select 0 when this is the case This is also the default Utilize the default E lt RETURN gt You are about to add the following SCSI device Host Adapter Adapter Type Device Number D LUN eiad Srom 0 5 0 Update SCSI configuration y n Acknowledge E y lt RETURN gt The SCSI configuration file has been updated Do you want to configure a CD ROM TAPE installation device y n The installation of SCO software willbe supported by the CD if y is selected In orderto utilize the CD ROM drive itis not necessary to enter y here Enter either y orn E n lt RETURN gt Do you want to add configure the high sierra file system y n In order to mount CD ROM s with a file system a y must be acknowledged here E y lt RETURN gt 9 12 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation High Sierra 1809660 file system Configuration Program 1 Add High Sierra 1509660 file systemto system configuration 2 Remove High Sierra 1509660 file system from system confi guration Select
40. eted Press lt Enter gt to continue The MOD driver is now installed and an MOD has had a file system created on it This type of MOD can be mounted for example in the directory mnt by the super user using mount dev mod mnt Siemens AG 465 981 7101 23 Edition 02 96 9 41 SIMADYN D STRUC G User manual 9 Installation 1 2 7 Installing a Printer 1 2 7 1 Listing Installed Printers Proceed as follows in order to check whether printers have already been installed on your system Log inasroot and open an UNIX window with a double click on the UNIX icon The operating system must now be in the Multi User Mode see Chapter 2 2 Use the program pi nstal l to list the installed printers Ei pinstall lt RETURN gt Merge Printer Installation Program 1 Install a Printer 2 Remove a Printer 3 List Printers Enter Option Enter 3 to list the printers E 3 lt RETURN gt You will receive a similar reply Number of Printers Installed 2 ps_struc wdv Press ENTER to continue Enter lt RETURN gt and then q in order to exit this program 9 42 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Merge Printer Installation Program 1 Install a Printer 2 Remove a Printer 3 List Printers q Quit Enter Option q lt RETURN gt The command pstat p printer name will give you further information regarding the printer E ipstat p wdv lt RETURN gt prin
41. for operation in the docking station The change in the configuration file is activated with the next restart of the operating system D Invoking eth_on_off Log in root cd simadyn struc 423 install lt RETURN gt in root directory simadyn eth_on_off lt RETURN gt 9 46 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation 1 4 Displaying the Hardware Configuration You can display the drivers linked to the operating system by using the program etc hwconfig h It describes the status of the operating system at the previous start up If you have altered the operating system kernel and not carried out a warm start i ni t 6 then the program will not display the current information E etc hweonfig h device address vec dma comment f pu 139 Cr type 80387 serial Ox3f8 Ox3ff 4 unit 0 type Standard nports l floppy Ox3f2 0x3f7 6 2 unit 0 type 135ds18 floppy unit 1 type 96ds15 console unit vga type 0 12 screens 68k tape 0x300 0x304 5 type wangtek eisarom eisa 1 3 0 hped 0x2c00 Ox2cff 11 3 type HP EISA 32 addr 08 00 09 35 04 ee disk 0x1f0 0x1f7 14 type W0 unit 0 cyls 659 hds 16 secs 63 disk type W0 unit 1 cyls 659 hds 16 secs 63 Each line describes a driver The contents of the line is dependent upon the type of driver The line starting with serial describes for example a driver for a serial interface with address range 3f8 3ff and interrupt
42. ins the generated driver for the parallel interface Reply with y to the following prompts Siemens AG 465 981 7101 23 Edition 02 96 9 31 SIMADYN D STRUC G User manual 9 Installation E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y lt RETURN gt Backing up unix to unix old Installing new unix on the boot file system The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y lt RETURN gt The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Press lt ENTER gt to continue lt RETURN gt Activate the new kernel by shutting down and subsequently restarting the operating system H init 6 lt RETURN gt 1 2 4 Install a Driver for a Serial Interface This examples assumes that your PC contains atleast two Serial interfaces compatible with the IBM PC standard and that one Serial interface has already been installed A driver for the second interface is then to be installed It utilizes the address 2f8 Log in as root and open a UNIX window with a double click on the UNIX icon Switch the computer into single user mode H init 1 lt RETURN gt
43. ion parallel port in order to enter the window for the installation of the parallel interface Proceed in this window as follows There are no parallel ports configured Do you wish to 1 Add a parallel port 2 Remove a parallel port 3 Show configuration 4 Help Select an option or enter q to quit Enter 1 to add a parallel interface E 1 lt RETURN gt Please select the I O address for the adapter 1 Parallel Adapter at address 378 37f 2 Parallel Adapter at address 3bc 3be 3 Parallel Adapter at address 278 27a 4 Other configuration Select an option or enter q to quit Enter 3 to select the address range 278 27a E 3 lt RETURN gt Should this port use interrupt default 7 You will be prompted for the utilized interrupt request number If there is no reason to discard the suggested number enter and acknowledge this value A possible reason to enter another value would be a conflict with another board utilized in the device E 7 lt RETURN gt You will be informed about the generated driver dev p0 you require this information for the printinstallation and you will be prompted as to whether you wish to re link the operating system kernel The device node is dev I p0 You must create a new kernel to effect the driver change you specified Do you wish to create a new kernel now y n The operating system kernel must be re linked in order to activate your set up The new kernel then conta
44. ledge all further prompts with lt RETURN gt permit the program to alter the file CONFIG SYS and AUTOEXEC BAT and exit the program with y Remove the disk from the drive 1 5 3 3 Testing the Prommer Attention For SCO UNIX ODT 5 0 select directory d instead of c The access to the prommer can be tested subsequent to the machine installation with the item bur n and the installation of the prommer device driver 9 64 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Invoke the DOS emulation as follows E dos tamcrd340 lt RETURN gt Switch in the DOS emulation to the directory in which the driver software is located i e C si madyn par prom H c lt RETURN gt cd simadyn parprom lt RETURN gt Invoke the program mel copy E mel copy lt RETURN gt Selectthe menu itemTools gt Drive Status inthis program The status of the drive is displayed on screen when the installation has been correctly implemented No drive errors should be displayed Siemens AG 465 981 7101 23 Edition 02 96 9 65 SIMADYN D STRUC G User manual 9 Installation 1 6 Initializing the STRUC G User The user data must be initialized after loading and configuring the STRUG G packet The STRUC file directory structure is thereby created by the user Directories in the User Specific Working Homedirectory Diagram 1 8 User Data Layout The data created by the user is located in the directory
45. ledge with lt RETURN gt E lt RETURN gt You will be prompted to specify your prommer WORKBENCH DIRECTORY is simadyn struc 42 Enter the programming device in the system files par External parallel programmer int Internal parallel programmer me MEL PC drive cancel Do not enter a device get prom ush gt Select the corresponding device This example will utilize the internal parallel programmer E int lt RETURN gt You will be prompted for the device s address range and interrupt request number Acknowledge the default set up Changing the default set up should only be undertaken after reviewing the prommer documentation This also applies to the MEL drive If you are utilizing the external parallel programmer then you must specify the address of your parallel interface and its interrupt vector Change the defaultifnecessary Thepromptport address requires an address group of three addresses inthe formStart address End address three characters for the start address hyphen three characters for the end address The three standard addresses for the parallel port are the groups 9 62 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation 278 274 378 37a 3bc 3be Parallel Programmer intern Port address Default 278 27a lt RETURN gt Interrupt number Default 5 lt RETURN gt The data is saved after acknowledging with lt RETURN gt subsequently the in
46. lt RETURN gt Backing up unix to unix old Installing new unix on the boot file system The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y lt RETURN gt The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Press lt ENTER gt to continue 9 34 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation The operating system kernel is then re linked Activate these alterations by shutting down and subsequently restarting the operating system H init 6 lt RETURN gt 1 2 5 Install a Driver fora CD ROM Drive This example assumes that the CD ROM drive has not yetbeen installed and itpossesses an SCSI interface The system has an SCSI controller host adapter for which the operating system utilizes the abbreviation eiad this abbreviation is fixed by the operating system Itdepends upon the type of SCSI controller The SCSI controller is already installed The identification number of the CD ROM drive atthe SCSI bus is 5 this value is setoris to be set on the drive itself A CD ROM can contain a file system This type of CD ROM can be installed into the system as a hard disk read only To support this a directory is created in the following example in which the file system ofa CD ROM c
47. mens AG 465 981 7101 23 Edition 02 96 9 3 SIMADYN D STRUC G User manual 9 Installation 1 1 1 Shutting Down and Restarting the System The operating system must be shut down and subsequently restarted in order to implementthe steps described in the following sections You mustlog in as the root see section LEERER MERKER and reconfigure the system to single user mode also System Maintenance Mode in order to alter the operating system kernel The following overview shows the commands required for shutting down and restarting the operating system Transition to the single user mode all users must be logged off the system H init 1 lt RETURN gt This procedure requires a lengthy period of time The system outputs a series of messages The exact contentis dependent upon your system configuration INIT New run level 1 The System is coming down Please wait System services are now being stopped cron aborted SIGTERM ISI GTERM NFS Shut down Print services stopped TCP Shut down Stopping TCP IP daemons slink exiting SIGTERM TCP Shut down Compl ete Stopping scologin done The System is down INIT New run level INIT SINGLE USER MODE Type CONTROL d to proceed with normal startup or give root password for system maintenance Enter lt CTRL gt d at this point to restart the system in multi user mode Enter the super user password in order to switch to single user mode Warm
48. menu now appears Display Partition Table Use Entire Disk for UNIX Use Rest of Disk for UNIX Create UNIX Partition Activate Partition Delete Partition Create Partition ee ee iB Enter your choice or q to quit Enter q in order to exit the fdisk menu E q lt Return gt You will now enter a menu which permits processing modes for your partition Exit this menu by entering q once again E q lt Return gt Other outputs can also appear dependent upon whether you have inserted an empty MOD or an MOD with file system The following assumes that you have inserted an empty MOD 0 Bad blocks have been found Enter the number of bad blocks to allocate space for or press lt Return gt to use the existing value of 511 WARNING Changing the value will remove all file systems in this partition Use the default value at this point and acknowledge with lt Return gt E lt Return gt There are 121856 blocks in the Unix area Please enter the number of file systems you want this area to be divided into or press lt RETURN gt to get the default of 1 file system s Enter lt RETURN gt for the default of 1 E lt RETURN gt The layout of the file systems and swap area is now prepared Do you wish to make any manual adjustments to the size or names of the file systems or swap area before they are created on the hard disk y n Enter y E y lt RETURN gt Making file systems Hard Disk initialization procedure compl
49. must be specified for this driver Therefore enter for example 9600 E 9600 lt RETURN gt Siemens AG 465 981 7101 23 Edition 02 96 9 33 SIMADYN D STRUC G User manual 9 Installation The following etc gettydefs F entries support 9600 baud lines 1 9600 console 9600H 0 6 m sc m san Ww amp S Ww MN Choose one of the above entries or q to quit Enter for example 1 E 1 lt RETURN gt Configuration files are then modified You will be informed that two drivers have been generated dev tty2a and dev tty2A dev tty2A can control modems It is subsequently necessary to re link the operating system kernel and to shut down and subsequently restart the operating system in order to activate these modifications Modifying system files No terminals needed adding to the Terminal Control database System files successfully updated The following standard serial device s have been installed tty2a The following device s access the same physical port as their lower case counterpart but have modem control properties tty2A You must create a new kernel to effect the driver change you specified Do you wish to create a new kernel now y n Reply with y to all subsequent prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y
50. new kernel to effect the driver change you specified Do you wish to create a new kernel now y n Siemens AG 465 981 7101 23 Edition 02 96 9 7 SIMADYN D STRUC G User manual 9 Installation The operating system kernel must be re linked in order to activate the new set up The new kernel then contains the driver for the parallel interface that you have generated Reply with y to all further prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y lt RETURN gt Backing up unix to unix old Installing new unix The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y lt RETURN gt The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Activate the new kernel by shutting down and restarting the operating system E init 6 lt RETURN gt 1 1 4 Installing a Driver for a Serial Interface This example assumes that your PC contains atleast two IBM _PC standard serial interfaces and that one serial interface has been previously installed The driver is installed for the second interface It is assigned the address 218 Log inasroot and bring the
51. now simply assume that your workbench is si madyn struc 423 The installation of the STRUC G master is continued by invoking the installation program 1 5 2 The Installation Program Invoke the installation program in the sub directory i nstal ofthe workbench directory as follows H cd simadyn struc 42 install lt RETURN gt install lt RETURN gt If you are invoking the installation program for the first time you willbe prompted for the language thatSTRUC G is to utilize If STRUC G has been loaded from diskette then the files must first be uncompressed This will take a certain amount of time The following message appears Wel che Sprache soll STRUC G benutzen 9 50 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Bitte wahlen Sie eine Sprache aus und geben Sie die entsprechende Nummer ein Which language do you want STRUC G to use Please choose one of the following and enter the appropriate number 1 deutsch 2 english We will assume that you will select 2 for English E 2 lt RETURN gt This setting can be changed ata later time point in the menu item ang ofthe installation program This setting defines the language for the installation program and all STRUC G programs The installation menu is subsequently displayed on screen Installation 4 2 3 I NSTALLATI ON MENU STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master
52. nstallation Lang permits you to change the STRUC G system language This setting specifies the language of the installation program and all STRUC G programs E lang lt RETURN gt Wel che Sprache soll STRUC G benutzen Bitte Waehlen Sie eine Sprache aus und geben Sie die entsprechende Nummer ein Which language do you want STRUC G to use Please choose one of the following and enter the appropriate number 1 deutsch 2 english We will assume in this manual that you have selected 2 for English E 2 lt RETURN gt The installation menu is then displayed once again I NSTALLATI ON MENU STRUC G Installation Types Siemens AG 465 981 7101 23 Edition 02 96 SIMADYN D STRUC G User manual 9 Installation init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt 1 5 2 6 Burn Declaring the Prommer to the Operating System This step declares to the operating system the type of prommer you wish to utilize This step does notinstall the prommer driver software The prommer driver normally runs under the DOS emulation Please review the remarks in section 9 2 3 E burn lt RETURN gt Please enter the WORKBENCH DI RECTORY Default simadyn struc 423 install gt Acknow
53. nt causes the system to continue in the multi user mode Enter the super user password to switch to single user mode System warm start shut down and immediate re start Reboot E init 6 lt RETURN gt or E reboot lt RETURN gt Utilize the command r eboot only in the single user mode i nit 6 can also be utilized in the multi user mode Re start the system from the single user mode to the multi user mode E init 2 lt RETURN gt System shut down prior to power down E init 0 lt RETURN gt or E shut down g0 0 i0 y lt RETURN gt 1 2 2 Log in as Super user root Select an alpha numeric or the graphical console The operating system makes several Logical screens available that can be switched to the display unit This type of Logical screen is known in the following as console You can access the various consoles by entering the key combination lt CTRL gt lt ALT gt lt FX gt Simultaneously pressing the keys lt CTRL gt and lt ALT gt and one of the function keys lt F1 gt to lt F12 gt The graphical console is linked with the function key lt F2 gt all the others are usually an alpha numeric screen A window will appear on the graphical console for entering the user name and user password Siemens AG 465 981 7101 23 Edition 02 96 9 29 SIMADYN D STRUC G User manual 9 Installation sco login Password Diagram 1 4 Graphics Console The graphical shell is displayed after
54. nts are installed in usr lib X11 fonts misc Start the machine initialization E init lt RETURN gt The workbench directory is displayed Subsequently you will be requested to specify your promming unit in order to declare it to the operating system WORKBENCH DIRECTORY is simadyn struc 423 Enter the programming device in the system files par External parallel prommer int Parallel Programmer intern me MEL PC drive cancel Do not enter a device get prom ush gt Select the corresponding device Press cancel if you do not wish to implement this step at this time You can repeat this step ata later time point with burn Remarks Concerning the Prommer This step does notinstall the driver software for the prommer It only declares to the UNIX operating system which driver is to be utilized for promming The prommer driver normally runs under DOS emulation Please refer to the remark in section 9 2 3 This example will use the internal parallel prommer E int lt RETURN gt Prompting occurs for the device s address range and the interrupt request number Acknowledge the default setting Alterations with respect to the default should only be undertaken after referring to the prommer documentation This is also applies to the MEL drive If you are utilizing an external parallel prommer then you must specify the address of the your parallel interface and its interrupt vector Change the defaultsetting acco
55. o Acknowledge with lt RETURN gt when these specifications are correct The program is terminated if you enterno E lt RETURN gt The necessary directories and files are created Creating the STRUC G Structure MAKEDIR scousr00 bern struc Ink_ awd MAKEDIR scousr00 bern struc ver MAKEDIR scousr00 bern struc Ink_igr Setting the user protection rights in the STRUC G structure The necessary STRUC G structure has been created You have the possibility at this point to set corresponding protection rights for this structure The following protection rights are placed with the Supplied program 1 Each group member of the struc group is permitted to access the working area of other group members in that group 2 Persons not belonging to struc group have no rights to work with this groups data Further information can be obtained fromthe Installation Guide Do you want to protect the struc group area y yes Default Siemens AG 465 981 7101 23 Edition 02 96 9 67 SIMADYN D STRUC G User manual 9 Installation n no You have the opportunity at this point to define the access rights to your user data If you acknowledge you will receive the rights to read write and execute All other users receive the rights to read and execute Setting these rights requires a certain amount of time E lt RETURN gt acl _home ush setting the protection rights for the user working area You have now initialized user bern with the group struc to work
56. o activate your changes Configuration files updated To relink the kernel type link unix After the kernel successfully links reboot by typing fetc shut down and the new system will be invoked 9 24 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Press any key to continue Press any key to conti nue when requested to do so to re display the start screen To link the operation system kernel selectRebuild Relink kernel Acknowledge all further prompts with y Executing command sh c cd etc conf cf d exec etc conf cf d link_unix The UNIX Operating System will now be rebuilt This will take a few minutes Please wait Root for this system build is The UNIX Kernel has been rebuilt Do you want this kernel to boot by default y n y lt RETURN gt Backing up unix to unix old Installing new unix The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y lt RETURN gt The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Press any key to continue Press any key to return to the start screen Press the lt ESC gt as many times as is necessary to return to the menu line originally displayed during the program Start SelectQuit gt Yes to exit the program Acti
57. print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt You can now implement the various installation steps Enter one or several characters for the installation type i forinit c forcopy etc The first step implemented after loading the data should bei nit The machine installation is ready for operation after implementing i ni t In order to print your drawings you should implementthe step pri nt Setting the access rights item ac and defining the prommer item burn is automatically implemented with i nit You can abortthe installation program atany time by pressing lt DEL gt Previously implemented installation steps are not negated by this Aborting can however possibly leave currently processed files in an inconsistent state Therefore always terminate the installation program with end 1 5 2 1 Init Machine Initialization The following occurs in this step Siemens AG 465 981 7101 23 Edition 02 96 9 51 SIMADYN D STRUC G User manual 9 Installation A change of et c def ault 1 pd ensures that banner pages are not automatically printed The STRUC G icon is loaded into the directory usr lib X11 XDesktop3 applications The promming unit is declared to the operating system The accessing rights of the machine installation are set STRUC G host fo
58. programs ys admsh to alter the operating system parameters E sysadmsh lt RETURN gt The menu sequence System gt Configure gt Kernel is to be selected i e by entering the three characters s c and k Select the menu item Parameters Tune Kernel params in the display screen by entering p or selecting with the cursor keys and entering lt RETURN gt The following parameter overview is displayed Executing command sh c cd etc conf cf d exec etc conf cf d configure Disks and Buffers Character Buffers Files Inodes and File systems Processes Memory Management and Swapping Clock on S WwW Pe Fr 14 Security 15 Asynchronous 1 0 Select a parameter category to reconfigure by typing a number from 1 to 15 or q to quit Enter 4 to alter the parameters for processes memory management and swapping E 4 lt RETURN gt You will be informed that the name and value of each parameter is displayed and you have the opportunity of entering lt RETURN gt to retain the value enter anew value and lt RETURN gt to alter the parameter and enterq lt RETURN gt to terminate the processing The first parameter NPROC is displayed The name of each parameter in this category will be displayed along with its current value To retain the parameter value press lt Return gt To change the parameter value enter the new value and press lt Return gt To exit this category type
59. pt output Al and portrait PSAxP Postscript output Ax and portrait PSA6P Postscript output A6 and portrait Please enter the corresponding printer type h list of all permissible entries get _print ush gt E PSA4 lt RETURN gt Please enter a printer number 0 99 q terminate and save e terminate without saving 0 99 delete a printer entry get_print ush gt You can now configure a further printer terminate with or without saving the data or erase a previously configured printer Example for erasing an entry Dl 9 lt RETURN gt Enter q to save the printer configuration E q lt RETURN gt Generate the printer plotter user shell If print has not been implemented for the first time then you will be prompted to either generate the corresponding files gen orto skip this step s ki p An automatic generation is carried out during the firstpr i nt run Please enter gen to generate or skip to skip the generation struc _men gen ush gt E gen lt RETURN gt 9 58 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Initialization of the printer user shell completed STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Inst
60. q and press lt Return gt NPROC maximum number of processes system wide The current value is 100 New value is Enter the value 300 at this location E 300 lt RETURN gt The next parameter is displayed Siemens AG 465 981 7101 23 Edition 02 96 9 23 SIMADYN D STRUC G User manual 9 Installation MAXUP maximum number of processes available to user The current value is 25 New value is Enter 100 E 100 lt RETURN gt NREGI ON number of regions allocated The current value is 300 New value is Enter945 The value of NREGION should always be a little more than three times the value of NPROC If you have entered a value for NPROC not equal to 300 then NREGION should be adapted correspondingly E 945 lt RETURN gt Now enter lt RETURN gt as many times as required until the parameter overview appears again Disks and Buffers Character Buffers Files Inodes and File systems Processes Memory Management and Swapping Clock Oe wWwnNn ee 14 Security 15 Asynchronous 0 Select a parameter category to reconfigure by typing a number from 1 to 15 or q to quit Enter q and ay to the following prompt in order to exit the screen and save your alterations E q lt RETURN gt Would you like to update the system configuration files with your changes y n y lt RETURN gt You will be informed that the operating system kernel must be re linked the operating system shut down and restarted in order t
61. r configuration y yes default n no n lt RETURN gt STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt 1 5 2 4 Acl Set Access Rights This item permits the definition ofthe access rights to files and directories ofthe machine installation The rights are setas follows the super user root has rights to read write and execute invoke programs search in directories all other users have the right to read and execute The names of the implicated files and directories are displayed The installation menu is subsequently displayed and you can continue with further steps Start the access rights set up As usual you will be initially prompted for the workbench directory DB acl lt RETURN gt Tcont 9 60 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt 1 5 2 5 Lang Setting the Language 9 I
62. rding to yourspecific hardware set up The prompt port address requires an address group of three addresses in the form ofStart address End address three characters for the start address hyphen three characters for the end address The three standard addresses of the parallel port are therefore the groups 278 274 378 37a 3bc 3be Parallel Programmer intern Port address Default 278 27a lt RETURN gt Interrupt number Default 5 lt RETURN gt When lt RETURN gt is pressed the data is transferred and subsequently the access rights are set for the machine installation The name of each file concerned is displayed The installation menu is subsequently displayed and you can continue with other steps 9 52 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation cont STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt 1 5 2 2 Copy Copying the STRUC G Master This installation step permits a STRUC G master to be copied Select copy in the installation menu E copy lt RETURN gt WORKBENCH DIRECTORY is simadyn struc 42 Please enter the complete path name of the copy of the STRUC G system that you wish Def
63. rdware Kernel Manager Click on the location Hard Disk in order to enter the window for the installation of the hard disk Proceed in this window as follows Your root disk is attached to a SCSI controller Pick one of the choices below or you may quit and invoke mkdev hd u for a detailed usage massage 1 Add a hard disk to DE Controller 2 Add a hard disk to SCSI Controller 3 Add a hard disk to IDA Controller 1 Enter 1 2 3 or enter q to quit Entera2 atthis location forthe SCSI controller E 2 lt RETURN gt Enter the prefix of the SCSI host adapter that supports this device or press lt Return gt for the default eiad Enter h for a list of host adapters or enter q to quit Enter the abbreviation for your type of your SCSI controller In our example it is the default value eiad E lt RETURN gt 9 38 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Which eiad SCSI host adapter supports this device Select 0 1 or q to quit Our example contains exactly one SCSI controller in the system Therefore enter 0 E o lt RETURN gt The Host Adapter parameters will be automatically configured What SCSI Bus is this device attached to Press lt Return gt to use the default 0 Select 0 n or h for help or q to quit 0 In our example the default setting is to be accepted E lt RETURN gt What is the Target ID for this device Select 0 15 or h for help
64. responding keyboard type The table containing the corresponding number from which the keyboard type can be selected is located in the SCO Open Systems Software International Supplement in chapter 2 Installation Procedure on page 25 We will select the number 3 PS2 keyboard German Other possibilities for German keyboards are from the above mentioned table PS 2 style keyboards 3 German PC AT style keyboards 19 German PCHAT style keyboards on a system using ISO 8859 mapchan 25 German PSZ style keyboards using code page 850 35 German Siemens WX200 style keyboard 51 German 9 26 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Enter the option number for your keyboard type 1 54 or type q to quit 3 lt RETURN gt Several outputs will follow this Do you wish to configure automatic character set mapping y n Reply with n E n lt RETURN gt Enter lt ESC gt until the first screen is displayed again SelectQuit gt Yes atthis location and exit the program Invoke the programs ysadmsh E sysadmsh lt RETURN gt Select the menu nternational withSystem gt Configure gt International Select the menu item System Make the following entries in this screen InSelect one selectAdd Then make the following entries Specify language German Specify country region Germany Specify code set 8859 Pressing lt RETURN gt subsequent
65. room 439 PS 1 wdv_cgm A4 in room 425 CGM 6 qms 410 A3 in room 375 PSA4 7 qms 810 A3 in room 375 PSA3P 9 qms A3 in room 371 Bldg 28 PS Please enter a printer number 0 99 q terminate and save e terminate without saving 0 99 delete a printer entry get _print ush gt The following describes the configuration of an A4 postscript printer with the nameps_ struc Enter a number You can select a number anywhere between 0 and 99 E 0 lt RETURN gt Please enter the corresponding printer name get _print ush gt E ps_struc lt RETURN gt The following message is displayed if the entered printer cannot be accessed Warning printer ps_ struc is not set up The warning signifies either that an incorrect printer name has been specified or that the printer has not yet been installed Please enter the corresponding menu text get _print ush gt E Postscript A4 in room 15 lt RETURN gt Please enter the corresponding printer type h list of all permissible entries get _print ush gt Siemens AG 465 981 7101 23 Edition 02 96 9 57 SIMADYN D STRUC G User manual 9 Installation E h lt RETURN gt The following entries are permissible CGM CGM out put PS PSL PSA4 PSA4L Postscript output A4 and landscape PSAl PSAIL Postscript output Al and landscape PSAx PSAXL Postscript output Ax and landscape PSA6 PSA6L Postscript output A6 and landscape PSP PSA4P Postscript output A4 and portrait PSAIP Postscri
66. s device or press lt RETURN gt for the default eiad Enter h for a list of host adapters or enter q to quit Enter the abbreviation of your SCSI controller type Our example is the default eiad E lt RETURN gt Which eiad SCSI host adapter supports this device Select 0 1 or q to quit Our example has exactly one SCSI controller in the system Enter 0 E o lt RETURN gt What is the Target ID for this device Select 0 7 or h for help or q to quit Our MOD drive has the number 3 E 3 lt RETURN gt What is the LUN of this device Press RETURN to use the default 0 Select 0 7 or h for help or q to quit 9 14 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation The controller ofthe MOD and the MOD drive are normally one constructive unit Therefore select 0 This is also the default E lt RETURN gt You are about to add the following SCSI device Host Adapter Adapter Type Device Number D LUN eiad Sdsk 0 3 0 Update SCSI configuration y n Acknowledge E y lt RETURN gt The SCSI configuration file has been updated A new kernel must be built and rebooted before disk configuration can continue Would you like to relink at this time y n The operating system kernel mustbe re linked in order to detectthe MOD Entera y forthis and all further prompts E y lt RETURN gt The UNIX Operating System will now be rebuilt This will take a few minutes Please wait
67. s not practical to install STRUC G 4 2 3 Over a previously existing STRUC G machine installation in the same directory without previously erasing the data since the STRUC G master file structure has changed Installation Parallel to an Older STRUC G Version Assuming that your old version is located in si ma dyn struc ensure that the root directory of your old version does not have the name struc 42 If the namestruc 42 has been utilized then it must be renamed and all the users of the older version must be requested to repeat the user initialization We will assume that the root directory of your old version is called st ruc the complete path name is simadyn struc Switch to the directory si madyn Now you can continue loading the packet with the command t ar see following section cd simadyn lt RETURN gt The paket is thereby loaded into the directory simadyn struc423 9 48 Edition 02 96 Installation Instead of an Old STRUC G Version If you have an older STRUC G version already installed and this is no longer required then you can proceed as follows We recommend that your older version should be erased after the installation of the STRUC G 4 2 since the printer configuration of the older version can be transferred during the installation It is assumed that your old version is located in simadyn struc ensure that the root directory does not have the namestruc 42 Ifthe name struc 42 has
68. stallation menu is displayed once again and you can continue with further steps I NSTALLATI ON MENU STRUC G Installation Types init Machine initialization copy Copy the STRUC G Master print Define printer configuration acl Setting the protection rights for STRUC G lang Setting the language burn Declare prommer to system end Installation termination Please enter the Installation type install gt 1 5 2 7 End Exit Installation Selecting end in the installation menu terminates the installation E end lt RETURN gt Further information can be obtained fromthe installation instructions Exit with lt RETURN gt install gt Acknowledge with lt RETURN gt to exit the installation program E lt RETURN gt 1 5 3 Install the Prommer Software 1 5 3 1 Parallel Prommer A driver for the parallel prommer is supplied with the device The installation of the parallel prommer is described in the document Digital Control System SIMADYN D Parallel Prommer Siemens AG 465 981 7101 23 Edition 02 96 9 63 SIMADYN D STRUC G User manual 9 Installation Internal and External Device Item No 465 982 7002 20 The software is installed in the DOS emulation If your machine installation is located in si madyn struc 42 then selectthe destination directory for example as C si madyn parprom and not C si madyn in the installation program so that your prommer driver is installed in a separate sub director
69. stalling new unix on the boot file system Siemens AG 465 981 7101 23 Edition 02 96 9 37 SIMADYN D STRUC G User manual 9 Installation The kernel environment includes device node files and etc inittab The new kernel may require changes to etc inittab or device nodes Do you want the kernel environment rebuilt y n y The kernel has been successfully linked and installed To activate it reboot your system Setting up new kernel environment Press lt ENTER gt to continue lt RETURN gt The operating system kernel is now re linked Activate by shutting down and subsequently restarting the operating system H init 6 lt RETURN gt 1 2 6 Install a Driver for an MOD Drive This example describes the installation of an MOD drive with SCSI interface The SCSI controller is already installed The operating system utilizes the designation eiad for the SCSI controller The installation of a magneto optical disk is in principle exactly the same as the installation of a hard disk Insert therefore an empty MOD into the drive WARNING This MOD will be erased during the installation of the MOD drive The identification number Target ID of the MOD drive on the SCSI bus is 3 Log in as root and open an UNIX window by double clicking on the UNIX icon Switch the computer into single user mode H init 1 lt RETURN gt Switch to this folder with a double click on the icon System Administration and start the tool Ha
70. starting the system Shut down and immediate restart Reboot E init 6 lt RETURN gt or E reboot lt RETURN gt Only use the command rebootin the single user mode i nit 6 can also be utilized from the multi user mode Restarting the system from the single user into the multi user mode H init 2 lt RETURN gt 9 4 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Shutting down the system prior to powering down DQ init 0 lt RETURN gt or E shut down g0 0 i0 y lt RETURN gt 1 1 2 Login as Super User Root Select an alpha numeric or graphics console The operating system makes several Logical screens available that can be switched to the display unit This type of Logical screen is designated as console in the following You can prompt for the various consoles by entering the key combination lt CTRL gt lt ALT gt lt FX gt simultaneously pressing the keys lt CTRL gt and lt ALT gt and a function key lt F1 gt to lt F12 gt The graphics console is linked to the function key lt F2 gt All the others are usually linked to an alpha numerical console A window on the graphics console prompts for the entry of the user name and password OPEN SYSTEMS SOFTWARE sonon C oo pasma CO Diagram 1 1 Graphics Console The graphics shell diagram 2 2 is displayed after entering root lt RETURN gt the password and lt RETURN gt Double
71. t log off from the system before the modifications are made to the operating system 1 2 1 System Start Up and Shut Down The implementation of the steps described in the following chapters requires the operating system to be shut down and subsequently restarted Log in as the root in order to implement the operating system kernel alterations see Chapter LEERER MERKER and switch the system to single user mode also known as System Maintenance Mode The following overview indicates the commands required for shutting down and restarting the operating system Transfer to the single user mode all users must log off from the system H init 1 lt RETURN gt This procedure requires a lengthy period of time The system outputs a series of messages The exact content of these messages is dependent upon your system configuration INIT New run level 1 9 28 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation he Systemis coming down Please wait System services are now being stopped cron aborted SIGTERM ISI GTERM NFS Shut down Print services stopped TCP Shut down Stopping TCP IP daemons Slink exiting SIGTERM TCP Shut down Complete Stopping scologin done The System is down INIT New run level INIT SINGLE USER MODE Type CONTROL d to proceed with normal startup or give root password for system maintenance Entering lt CTRL gt d at this poi
72. talling a Driver for a Parallel Interface This example assumes that the parallel interface has been assigned the address range 378 37f and no driverhas been installed on this computer for the parallel interface Log inasroot and bring the computer into the single user mode Minit 1 Invoke the program mkdev parallel E mkdev parallel There are no parallel ports configured Do you wish to 1 Add a parallel port 2 Remove a parallel port 3 Show configuration 4 Help Select an option or enter q to quit Enter 1 to add a parallel interface E 1 lt RETURN gt Please select the I O address for the adapter l Serial Parallel adapter 1 address 378 37f 2 Parallel Monochrome adapter address 3bc 3be 3 Serial Parallel adapter 2 address 278 27a 4 Other configuration Select an option or enter q to quit Enter 1 to select the address range 378 37f E 1 lt RETURN gt You will be prompted for the interrupt requestnumber to be used Acknowledge when there is no apparentreason to discard the displayed value One possible reason to alter the value would be another board utilized in the device Should this port use interrupt default 7 E lt RETURN gt You will be informed of the generated driver dev p0 you require this specification for the printer installation and will be prompted as to whether you want to re link the operating system kernel The device node is dev I p0 You must create a
73. ted for example in the directory mnt by the super user with mount dev mod mnt 1 1 7 Installing a Printer Log in as root The operating system must now be in multi user mode see section 2 1 1 List the installed printers in order to check whether printers have been previously installed 1 1 7 1 Listing Installed Printers Utilize the program pi nstal to list all installed printers H i pinstall lt RETURN gt Merge Printer Installation Program 1 Install a Printer 2 Remove a Printer 3 List Printers Siemens AG 465 981 7101 23 Edition 02 96 9 19 SIMADYN D STRUC G User manual 9 Installation Enter Option Enter 3 to list all printers E 3 lt RETURN gt You will receive a similar reply Number of Printers Installed 2 ps_struc wdv Press ENTER to continue Enter lt RETURN gt and then q to exit the program Merge Printer Installation Program 1 Install a Printer 2 Remove a Printer 3 List Printers q Quit Enter Option q lt RETURN gt The command pstat p printer name permits you to display further information regarding a printer E ipstat p wdv lt RETURN gt printer wdv is idle enabled since Tue May 17 06 19 48 1994 available 1 1 7 2 Installing a Printer This example assumes that a postscript printer is to be installed Itis to utilize the parallel interface The driver for the parallel interface is dev p0 see section 2 1 3 The printer receives the
74. ter wdv is idle enabled since Tue Jan 01 06 19 48 1996 available 1 2 7 2 Install Printer This example assumes that you wish to installa postscript printer Itis to utilize the parallel interface The driver for the parallel interface is dev l p0 see Chapter LEERER MERKER The printer will receive the name os struc Log in as root and switch to this folder with a double click onthe iconSystem Administration Now switch using the same principle to the folder printer Double click onto the icon Printer Manager The printer manager window is then opened All printers are then listed with their names and designations dependent upon whether you have already installed printers see Chapter LEERER MERKER Proceed as follows E Printer Add Local A window is again popped onto screen in which the specific data of this printer is shown Our example will show the following Name Description Model possc F Device dev lp0 LPTO Md Diagram 1 5 Schematic Representation of the Add Local Printer Window with Entries for a Local Printer Siemens AG 465 981 7101 23 Edition 02 96 9 43 SIMADYN D STRUC G User manual 9 Installation The entries for the installed printer are now listed in the Printer Manager window for checking purposes Remark The settings and designations entered for this printer can also subsequently be altered in the menu item settings Set the following switches to permit the printer to operat
75. to the last entry will cause a return to the menu nternational Select the item Keyboard atthis point Enterps ibm ger into the screen If you possess another keyboard type then you can make the correct selection from a list appearing after entering F3 Enter lt ESC gt until the firstscreen appears once again SelectQui t gt Yes atthis location and exit the program Now make the following entries Bl cd Jusr lib X11 xsconfig lt RETURN gt xsconfig sh usr lib Xll csxmaps ibm usr lib keyboard ps ibm ger lt RETURN gt mv Xsco cfg lt RETURN gt The same name must be entered as was entered insysadmsh in the menu International in the item Keyboard this example ps ibm ger in the second line in front of lt RETURN gt The alterations become active when the operating system is shut down and restarted H init 6 lt RETURN gt Siemens AG 465 981 7101 23 Edition 02 96 9 27 SIMADYN D STRUC G User manual 9 Installation 1 2 Operating System SCO Open Server TM Release 5 You require the components described in this chapter for the following reasons D Driver for A parallel interface For connecting a printer with a parallel interface A serial interface For connecting to a SIMADYN D rack in IBS G graphical commissioning service with the function drawing editor A CD ROM Drive When you possess a CD ROM drive and STRUC G is supplied on CD An MOD Drive When you possess an MOD drive and STRUC
76. vate the new kernel by shutting down and restarting the operating system see section 2 1 1 E init 6 lt RETURN gt 1 1 10 Configure a German Keyboard The configuration of a PS2 keyboard with German key layout is described below You require the data carrier ofthe SCO operating system with the designation International Supplement and the manual with the title SCO Open Systems Software International Supplement for the configuration Switch the system to single user mode E init 1 lt RETURN gt Insert the diskette International Supplement and invoke the program Custom to install the International Supplement packet E custom lt RETURN gt Custom Siemens AG 465 981 7101 23 Edition 02 96 9 25 SIMADYN D STRUC G User manual 9 Installation Install Remove List Quit Install Software Select the menu sequence nstall gt A new Product gt Entire Product Installing custom data files When you are requested Insert System V 0 S International Supplement Floppy Vol 1 Acknowledge with lt RETURN gt the diskette is already in the drive Respond to the prompt Do you wish to change any of these y n Entern E n lt RETURN gt Reply with y to the prompt as to whether the keyboard table should be automatically loaded when the system is started up Do you wish to have a keyboard map automatically selected during system startup y n y lt RETURN gt You will be requested to enter the cor
77. was installed The commentis an unrestricted character string with a maximum length of 30 characters Itis utilized in the printer selection menu of the basic dialog and ofthe function drawing editor The printer type defines whether itis a post script or CGM printer Postscript printers also require the paper format in addition to the printer type The specification of CGM ora chain ofcharacters according to the pattern PS A1 A6 L P is also permitted as a printer type The section in are optional designates a range and an alternative If you do notspecify the format Al A6 then A4 is assumed If you do not specify the orientation P or L then L landscape is as sumed The screen output contains five examples of configured printers with the numbers 0 1 6 7 and 9 Parameter list for printers that STRUC G can use Column 1 is the printer id number 0 99 9 56 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 9 Installation Column 2 is the name which the operating system uses to access the printer The comment should not exceed 30 characters Permissible printer types are CGM and Postscript The printer types are encoded as follows PS A1 6 P L PS for Postscript Al to A6 the paper sheet format default A4 P L portrait or landscape orientation default L CGM CGM Printer Printer Comment Printer Number Name Type 0 lp A3 in
78. with STRUC G This user can now start STRUC G from his working area after logging in Please acknowledge with RETURN init user ush gt The user initialization is therefore completed Acknowledge with lt RETURN gt You can repeatthe user initialization This can be useful for example when a new STRUC G master was installed and a previously created user wishes to utilize the new installation Your user data will be retained All system specific files libraries programs etc will be newly loaded 1 6 2 Loading the STRUC G icon on to the User Desktop SCO UNIX Version 3 2 If STRUC G 4 2 3 P32 P 16 was installed the icon with the icon text STRUC G V4 2 3 is located in the template applications If STRUC G 4 2 3 PT was installed the icon with the icon text STRUC G V4 2 3_PT is located in the template a p plications Log in as user on the graphics console in order to fetch the icon into the user desktop Open the template applications with a double click Click on the STRUC G icon and pull itwith pressed mouse key to the desktop Release the mouse key over the desktop The STRUC G icon will remain sitting on the desktop Close the template applications via the file menu File gt Close SCO UNIX Version 5 0 The icon STRUC G 4 2 3 appears automatically on the user desktop With a double click on the icon STRUC G V4 2 3 respectively STRUC G V4 2 3 PT the version V4 2 3 is started 9 68 Edition 02 96 Siemens AG 465 981 7101 23 S
79. y of si madyn If you are using an external parallel programmer then you should have already installed your parallel interface Invoke the DOS emulation as follows dependent upon which address your parallel port possesses dos tal p0 When your port utilizes the address 378 dos talpl When your port utilizes the address 3bc dos tal p2 When your port utilizes the address 278 Subsequently select the port LPT1 LPT2 or LPT3 in the installation program at which the address of your parallel port is displayed 1 5 3 2 MEL Drive Attention For SCO UNIX ODT 5 0 select directory d instead of c A diskette with the necessary software is supplied with the MEL drive The software is installed in the DOS emulation A detailed description can be found in the product manuals supplied with the drive MEL Card Manager bzw MEL Card Slot Board Log in as root Invoke the DOS emulation E dos lt RETURN gt Insert the diskette MEL PCB Slot Board in the a drive and start the installation DQ a install lt RETURN gt MEL PCB Software Installation Enter the name of the directory into which the program files are to be copied for example C si madyn mel The directory C corresponds to the UNIX directory in the DOS emulation If you have already created the directory si madyn for your SIMADYN D software then C si madyn mel is a further sub directory of this E C simadyn mel lt RETURN gt Acknow