1. Empty Weight 495 lbs 224 5 kg Loaded Weight 995lbs 451 3 kg Premix Tank 60US Gallons 227 Finished Foam Capacity 1800 US Gallons 6814 Foam Discharge Distance Up to 95 Feet 29 m Air Cylinders 90 cu ft 2200 psi 151 6 bar Recharge Time 3 5 minutes 2 4 Transporting The Enforcer 60 should be secured when transporting in trailers or vehicles Enforcer One LLC Copyright 2012 Page 6 Chapter 3 Operating Instructions 3 1 Initial Setup The Enforcer 60 comes fully assembled The 60 gallon Premix Tank and Compressed Air e 7 broduct should be selected Cylinder must be filled prior to use The proper FireAd based on operational ambient temperatures and type of anticipated fires before putting the unit into service 2000 e 3 2 Firead Products 2000 e a Enforcer 60 should only be used with Firead products mixed at a 3 or 6 solution 2000 b Itis recommended that a Fireade Freeze Protected Product be used when positioning the unit outside during extended subfreezing weather 3 3 System Depressurization A Ensure the system is depressurized before conducting maintenance a Close the Air Cylinder Valves b Open nozzle until all air is deployed and working pressure gauge reads zero c Open Pressure Relief Valve 3 4 Preventative Maintenance Checks amp Services PMCS a It is recommended that the PMCS CHECKLIST be completed every month b Personnel
2. Operation and Maintenance Manual Enforcer One LLC Copyright 2012 Page 1 Table of Contents Chapter 1 Page Product Introduction 3 Product Warranty 3 4 Safe Operating Procedures 4 5 Chapter 2 Page System Description 6 System Specifications 6 Chapter 3 Page Operating Instructions 7 9 Recommended Foam 7 Preventative Maintenance Checks and Services 7 8 Chapter 4 Page Training 10 Chapter 5 Page Maintenance 11 Servicing and Maintenance Activities 12 16 Troubleshooting 16 17 OCE Enforcer One LLC Copyright 2012 Page 2 Chapter 1 Introduction 1 1 Manufacturer a The Enforcer 60 is Manufactured by Enforcer One LLC 180 Etowah Trace Suite B Fayetteville GA 30214 United States of America Phone 678 788 8413 Fax 6787 788 8415 E mail Info enforcerone com Website www enforcerone com b EnforcerOne is committed to the satisfaction of our owners and operators of the Enforcer 60 If you have any problems questions or concerns please contact EnforcerOne via phone Fax or E mail 1 2 Warranty Limited Warranty CAUTION User should read and follow all Safety Rules and Operating Instructions BEFORE first use of this product Enforcer One LLC warrants to the original owner user that Enforcer One LLC products will be free from failures due to defects in workmanship for a period of one year from the date of original purchase During the warranty period Enforcer One LLC at its sole
3. freezing There is a blockage in the Premix Tank a The Enforcer 60 does not have any special storage requirements if stored inside b A protective cover is recommended and should be used if the equipment is stored outside as this will reduce sun damage to hoses and gauges Enforcer One LLC Copyright 2012 Page 17
4. conducting the PMCS should be thoroughly familiar with the Enforcer 60 system and the information contained in this manual E Enforcer One LLC Copyright 2012 Page 7 Form E3PMCS Preventative Maintenance Checks and Services PMCS ws Checklist Date Completed Name y Signature 1 Conduct a visual inspection of the system for chaffing or loose hose s dirt corrosion or damage 2 Check the Air Cylinder for normal operating pressure 1800 2200 psi Ensure System is depressurized Disconnect Air Cylinders and pull out of unit Connect Air Cylinder Pressure Check Gauge Open Air Cylinder and check for normal operating pressure 1800 2200psi e Close Air Cylinder and slowly disconnect Pressure Check Gauge allowing for pressure bleed off f Ifthe Air Cylinder pressure is below 1500 psi remove recharge and anov replace the Air Cylinder The Air Cylinder should normally be left in the closed position 3 Check the Premix Tank Level a Disconnect fill tower Cap check liquid level b Fill up the Premix Tank if low 4 Check the tire condition Note any other Problems NE ee Enforcer One LLC Copyright 2012 Page 8 3 5 Operating Instructions Warning Always refer to the product MSDS for proper precautions and treatment s if foam is accidently ingested or sprayed in eyes mouth or nose a Extend hose ensure the Foam Discharge Nozzle is in the closed position Charge the system by turning t
5. discretion will repair or replace at no charge the product that in its sole opinion is defective The purchaser is responsible for packing the product for shipment and for charges to ship the product to the location specified by Enforcer One LLC including at the purchasers sole discretion insurance on the shipment Enforcer One LLC will return the product pre paid to the purchaser If the product has been altered modified or repaired in any way or if the failure is the result of misuse abuse or misapplication without the prior consent of Enforcer One LLC this warranty Shall be void and Enforcer One LLC shall have no obligation to repair or replace the failed The use of any foam product other than FireAde products will void the warranty Enforcer One LLC Copyright 2012 Page 3 Warranty continued When used in conjunction with sound fire management practices and strictly as per the manufacturer s instructions the products may provide protection against anticipated fires and may accelerate the extinguishing of existing fires CAUTION The unpredictable nature of fires the techniques used to apply product s as well as the knowledge understanding and judgment of the individual s attempting to extinguish or control them will affect the performance of Enforcer One LLC product s THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY FOR Enforcer One LLC PRODUCT S AND DISCLAIMS AND EXCLUDES ANY AND ALL IM
6. Maintenance for specific activities Maintenance Date Performed By Activit Completed Notes Comments TT Enforcer One LLC Copyright 2012 Page 12 Scheduled Maintenance Form EGOPMCS Maintenance Recommended Date Due DENKS Performed By Activity Interval Completed Air Cylinder Every 6 months Pressure Check Air Cylinder Annually Visual Inspection Air Cylinder Every 5 Years Hydrostatic Test Premix Cylinder Every 5 Years and Discharge Hose Hydrostatic Test Air Regulator Every 2 years Inspection ammm Enforcer One LLC Copyright 2012 Page 13 Unscheduled Maintenance Maintenance Activity DEK Performed Comments Notes Completed By Enforcer One LLC Copyright 2012 Page 14 5 7 Servicing Under Normal Conditions a System Pressure Check 1 Make sure that the Fill Tower Cap is secure and the Foam Discharge Valve is closed 2 Open the Air Cylinder Valve and check the air pressure on the High Pressure Gauge for normal operating pressure of 1800 2200psi Check the Working Pressure Gauge is in the normal operating position 150psi 4 Conduct a leak check if the High Pressure Gauge reads below 1500 psi or if the Working Pressure Gauge reads below 150 psi a Spray a soap solution on all airlines fittings b Tighten leaking fittings replace O rings or replace defective components 5 Bleed of any stored pressure through Pressure Relief Valve a b Changing and Servicing Air Cylinder Ens
7. PLIED WARRANTIES REGARDING THE PRODUCT S INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No person or entity is authorized to bind Enforcer One LLC to any other warranty obligation or liability to distributer purchaser or any third party for any loss of profits economic loss indirect incidental punitive special or consequential damages whatsoever and howsoever caused Operation or use of this or any Enforcer One LLC product for which this warranty is issued shall constitute acceptance of the terms hereof CAUTION Prior to attempting to operate this or any Enforcer One LLC product you MUST read and understand all directions and instructions in this user manual Until you have read and understand all CAUTIONS Warnings Requirements Instructions for Set up amp Testing Operation and Maintenance NO ATTEMPT should be made to operate this or any Enforcer One LLC product In order to assure that your Enforcer One LLC product s are ready when needed they must be regularly maintained as outlined FAILURE TO COMPLY WITH ALL CAUTIONS WARNINGS REQUIREMENTS INSTRUCTIONS PROCEDURES AND MAINTENANCE WILL VOID THIS WARRANTY amp MAY RESULT IN SERIOUS INJURY OR DEATH amp OR DAMAGE TO OR LOSS OF PROPERTY SAFE OPERATING REQUIREMENTS 1 DO NOT attempt to use this or any Enforcer One LLC product s if they appear damaged and or broken Missing or damaged co
8. epartment 4 2 Training Program of Instructions a Operators and Maintenance Personnel 1 PMCS 2 Normal and Cold Weather Operating Instructions 3 Emergency Procedures 4 Operation in live fire scenario b Maintenance Personnel 1 General Maintenance Instructions and Technical Assistance Foam Product Maintenance Log Servicing Under Normal and Cold Conditions Scheduled Maintenance Unscheduled Maintenance Troubleshooting Procedures Ses a eS S Storage and Protection ee EEE ee Enforcer One LLC Copyright 2012 Page 10 Chapter 5 Maintenance 5 1 General Instructions a It is recommended that the preventative and maintenance PMCS be conducted monthly b It is recommended that qualified personnel be assigned the responsibility to service and maintain the system c All maintenance activity should be documented and should include copies of the completed PMCS Checklist Premix Tank Filling Calendar type ratio of product used component changes and any other problems encountered A MSDS should be maintained for the type of foam being used 5 2 Technical Assistance Maintenance personnel should contact EnforcerOne whenever any problem arises that cannot be solved using the information in this manual or when unusual situations are encountered or expected a Enforcer One LLC Copyright 2012 Page 11 Form E60PMCS Enforcer 60 Maintenance Log Preventative Maintenance Checks and Services PMCS Refer to Chapter 5
9. he Air Cylinder Valves counter clockwise c Open the Foam Discharge Valve slowly to the full open position for model with Foam Charge Valve Grasp the nozzle with hand Aim the nozzle at the base of the fire and open valve to discharge foam 3 6 Cold Weather Operations a It is recommended that FireAde Climate Control Premix foam is used when freezing is anticipated 3 7 Emergency Procedures a Loose Hose 1 Go to the unit and close the Foam Discharge Valve 2 Go to the Nozzle and close the valve b No Foam Discharge 1 Check to see if Air Cylinder is full 2 Verify the Air Cylinder Valve is turned completely on 3 Ensure Air Pressure Hose is attached properly 4 Check for obstruction in discharge hose c Shut Down Procedures 1 Close the Nozzle Valve 2 Close the Air Cylinder Valve 3 Open Nozzle valve to depressurize the system 4 Secure discharge hose NT SSS Enforcer One LLC Copyright 2012 Page 9 Chapter 4 Training 4 1 Training Program a Training on the Enforcer 60 should be conducted or reviewed annually for all operators b Maintenance personnel should complete initial training and refresher training as required c Trainers should be thoroughly familiar with the system fire behavior hazard identification and basic firefighting techniques d Operator training should be accomplished in live fire scenarios Live fire training can often be accomplished through coordination with a local fire d
10. hreat ADDITIONAL INFORMATION http www usfa fema gov safety sheets htm htto www nfpa org education index html htto www ilpi com safety extinguishers html http www Enforcer One LLC com Manual Changes 1 EnforcerOne will provide equipment update changes to this manual on an as need basis This manual and associated updates will be posted on the EnforcerOne web site This manual supersedes all previous Operating Instructions for the Enforcer 60 system Enforcer is a registered trademark of EnforcerOne LLC FireAde is a registered trademark of Fire Service Plus Inc Enforcer One LLC Copyright 2012 Page 5 Chapter 2 System Description 2 1 General Information The Enforcer 60 Pressure Foam System utilizes compressed air to propel firefighting foam Enforcer 60 produces air aspirated foam providing a thick vapor sealing blanket that will inhibit re ignition The Enforcer 60 will produce up to 1800 gallons of finished foam with discharge duration of up to 4 5 minutes The system can be easily recharged by the end user 2 2 Model Configuration The Enforcer 60 consists of a Premix Tank which holds 60 gallons of pre mixed Fireade Two 2200 psi Nitrogen tanks are attached to the Premix Tank through a 150 psi regulator and hose assembly One 50 section of lay flat hose and one pistol grip style Nozzle 2 3 Specifications Height 38 5 97 79 cm Length 54 5 138 34 cm Depth 42 106 68 cm
11. inimum annually Air Regulator e Check Operation every 2 years Premix Tank e Pressurize and check for leaks annually amp e Hydrostatic testing should be completed every 5 years Discharge Hose Foam Solution e Follow Foam Manufacturer quality testing recommendations 5 10 Unscheduled Maintenance Unscheduled maintenance will need to be performed as required 5 11 Trouble Shooting the System Users should contact Enforcer One if malfunctions cannot be corrected after employing good troubleshooting practices Use the matrix on page 17 for assistance eee Enforcer One LLC Copyright 2012 Page 16 Trouble Shooting Matrix Problem or Symptom No Pressure on Gauges Foam Does Not Discharge From Hose Air line Leak System is Not Fully Discharging 5 12 Storage and Protection Possible Solution Air Cylinder Valve is not turned on Air Cylinder is empty Pressure Gauge is inoperative Broken or blocked air hose Air Regulator has malfunctioned Premix Tank is empty Air Cylinder is empty Air Cylinder is not turned on Nozzle is in the off position Nozzle valve has malfunctioned Blockage on dispensing hose Foam solution is frozen Air hose fittings are loose or broken Air line is pinched cracked or broken There is insufficient volume of air in the Air Cylinder The Foam Discharge Nozzle is not fully opening The Foam Discharge Hose has a restriction The Air Regulator has a malfunction The Foam solution is frozen or near
12. mponents MUST be properly repaired or replaced as soon as possible Enforcer One LLC Copyright 2012 Page 4 Safe Operating Requirements continued 2 1 3 DO NOT attempt to use this or any Enforcer One LLC product s if you are tired injured or under the influence of drugs medication or alcohol DO keep children and bystanders away from the area where Enforcer One LLC product s are in use DO NOT attempt to use this or any Enforcer One LLC product s in the event that the fire represents a situation that is beyond the capabilities of the Operator and or the Equipment DO follow the proper Set up Testing and Maintenance amp Inspection Procedures to assure that your Enforcer One LLC product s is are ready for use when needed DO exit the area IMMEDIATELY if progress in fighting the fire is not being made and DO NOT return to the area DO comply with all local Laws amp Regulations related to the proper use installation maintenance training and inspection of Fire Fighting Equipment WARNING The act of fighting fire is both hot and dangerous work Smoke heat unseen fumes gases and flames can be easily underestimated In the absence of the proper training protective gear and clothing extreme caution should be exercised to avoid serious injury or death If ever in an attempt to extinguish a fire you are unsure that progress is being made contain the fire if possible and move quickly and safely away from the t
13. ure the system is depressurized before conducting any maintenance on the system Extreme care should be used when transporting the Air Cylinder s iF 2 3 4 5 6 Ensure Air Cylinder Valves are closed Depressurize the system Lift out the Air Cylinders Have the Air Cylinder filled to 2200 psi by a certified technician Replace the Air Cylinder in the holder Reconnect the Air Cylinders c Refilling the Premix Tank 1 Close the Air Cylinder Valve Ensure System is depressurized Remove Fill Tower Cap Add water until Premix Tank is full Ur e o S Add appropriate amount of foam using funnel allowing clear water to be displaced from top of Premix Tank 6 Replace Fill Tower Cap ensuring it is tightened properly A 7 Important Note The Fill Tower Cap should be tightened by hand E n Enforcer One LLC Copyright 2012 Page 15 Refilling the Premix Tank continued 5 8 Servicing In Cold or Freezing Conditions Fill the Premix Tank with Fireade Freeze Protected Foam solution whenever temperatures are below 32 degrees Fahrenheit Freeze Protected Foam should be used in the concentrate form in cold or freezing temperature conditions 5 9 Scheduled Maintenance Interval Recommendations Component Maintenance Activity and Recommended Interval Air Cylinder e Check pressure every 6 months e Visual inspection and certification annually e Hydrostatic testing every 5 years e Wash with soap and water m