Home

89+E UPro PROGRAMMER

image

Contents

1. eSof Enriching Life through Knowledge 89 UPro 89 E UPro programmer woo A ie cie d O e o p Here is 89 UPro USB Programmer for 89 Series Microcontroller for Serial SST ATMEL EEPROM With on board ZIF Socket for easy insertion amp removing of ICs WINBOND Flash Programming Tool Enriching Life Knowledge XEIeSof Development System TO OUR VALUED CUSTOMERS I want to express my thanks to you for being interested in our products amp having confidence in EleSof Technologies It is our intention to provide you with the best quality products Furthermore we will continue to improve our product performance to better suit your needs EleSof Technologies The ATMEL name and logo the ATMEL logo AVR AVR Logo AVR Freaks AVR Freaks Logo AVR Studio IDIC megaAVR megaAVR Logo picoPower tiny AVR are trademarks of ATMEI Corporation All other trademarks mentioned herein are property of their respective companies and are only used for the purpose of identification or explanation amp to the owner s benefit with no intent to infringe www elesof com www projectsmaker com TABLE OF CONTENTS Introduction ccc cece cece ccc RR memes 4 FCA m P 4 DPC CHC ALOU ost edet EE EE EUREN ROME OP
2. If you want to learn more about our products please visit our website at www elesof com amp www projectsmaker com If you have any questions comments or business proposals do not hesitate to contact us If you are experiencing some problems with any of our products or just need additional information please place write mail or call to us at contact elesof com amp info elesof com 91 9911 7095 92 amp 91 9044 1359 01 www elesof com www projectsmaker com
3. 1 Connect Programmer to USB port amp Start Software Connect programmer to USB port RED LED permanent become ON and GREEN LED will blink once and become off It is normal indication of everything is ok and it is ready to use Step 2 Install USB Driver Insert the CDROM provided with programmer There will be a folder called USB Driver It contains a file UsbDriver exe clicks on that to install Step 3 Install Flashing Software Install Flashing software by running its setup 89 UPro exe from CDROM in folder Flashing Sof tware and follow onscreen instructions After setup is done it will install icon on desktop SIH UPro PROGIRAMIMIEIR Step 4 Run Flashing Software Run Flashing Software 89 E UPro exe Software should connect and show ONLINE icon green color at bottom Your programmer is ready to use ER Note Flashing Software 89 E UPro exe is only for Windows XP amp Windows 7 Enriching Life through Knowledge USER SOTQUT OT AUT OLIPO MANUAL o SEleSof 894E UPro IGS page Troubleshooting Failed to Connect in Software If you get Failed to connect error in software It is possible that virtual com port is not between COMY1 9 Change the COM port on your system from Device Manager Also you can try Reinstalling USB driver Below are the steps to change COM port on your system for 89 E UPro programmer hm Control Panel Sys Manage Map netwo
4. 4 E E T a E EE orate nism aad 4 SU PO ie IC 5 Getting Started First Time Use suse 5 e Step 1 Connect Programmer to USB port amp Start Software e Step 2 Install USB Driver e Step 3 Install Flashing Software e Step 4 Run Flashing Software Troubleshooting Failed to Connect in Software 6 7 WS 8 Flashing Steps 8 9 e Step 1 Connect 89 E UPro amp Run Flashing Software 89 E UPro e Step 2 Select Device e Step 3 Load file e Step 4 Auto Program Other Special Function 10 Other software options ccc cece cece cece eee eee een 11 Visit www elesof com www projectsmaker com USER 1 7 1 1 IS3FleSof 89 UPro IGS page Introduction lwww elesof com EE 89 UPro this programmer is for 89 series microcontroller devices in 20 amp 40 pin packages and supports various 8 pin serial EEPROM ICs socket enables easy insertion removal of devices for programming Programming is very fast since it is USB based No external power required since it is powered from USB port itself Features Simple and Easy to use e Auto Erase Lock Verify e Auto Identify connected programmer e Error checking and verification in built e Led s for Programming amp Power ON status e Supports 89 series amp seri
5. ATMEL Device AT83551 Vendor ATMEL Size 4K Bytes Adapter None Failure owes _ Success Step 3 Load file PC software takes HEX or BIN file for programming Load gt Select HEX file amp click OK To select recently used files you can click on down arrow amp select you will see following dialog when you load a HEX extension file You can keep all setting as default and click OK to select this file File Edit Device Operate Hardware Load Edt 8 Device Y Contig 85 Settings 7 Shortcut Operate Programmer Model 89 E UPro Devie Mode ATMEL 89 51 Q ou Bink us 0 diee Hit GFi 4 Protect Intel Hex A Erase ioe lore OtfsetHEX xa 4 Bytes Adapter None Failure b p Qi Online Mode SIH UPro PROGIRAMIMILEIR Step 4 Auto Program Click on Auto button to start programming process File Edit Device Operate Hardware e Load Ld Save Edit lt Device v 22 Config s Info 525 Settings A U T Shortcut Operate Programmer Model 89 UPro Device Model ATMEL 89551 Q auto lt Blank Enriching Life through Knowledge B USER CELULITA LITT MANUAL o SEleSof 894E UPro IGS 5 Other Special Function Locking Device to prevent c
6. al EEPROM devices e 40 pin ZIF socket for easy insertion amp removal e High speed writing 8kb flash file in 10 seconds e Powered from USB port No external power required e Informative window and access to latest programmed file e Lock of programs in chip supported to prevent program copying Specification SIH UPro PROGIRAMIMILEIR e Power 5V from USB Cable e Communication USB 2 0 compliant e Cable required USB A to B type for connecting PC or Laptop e Dimension 10x6 7 Cm Package Contain e Tested amp Ready to use USB Programmer e CDROM containing Flashing software USB Driver amp User Manual e USB Cable for connecting 89 E UPro to PC ov b Enriching Life through Knowledge B USER MANUAL 89 UPro jp IGS 5 O Q Supported ICs ICs supported by 89 E UPro are mentioned below Atmel Winbond SST Serial EEPROM Serial EEPROM AT89C51 W78E51 SST89C54 AT24C01 AT93C46 AT89C52 W78E52 55 189658 24 02 AT93C56 AT89S51 SST89C59 AT24C04 AT93C66 89552 SST89E54RD 24 08 AT89S53 SST89E58RD AT24C16 8958252 SST89E554RCO AT24C32 AT89C1051 AT24C64 AT89C2051 AT24C164 AT89C4051 Getting Started First Time Use Below steps are mentioned for using 89 E UPro programmer for programming supportive ICs and this is first time required if system change than again need to follow the same steps mentioned below to work o that system Step
7. are File Edit Device Operate Hardware gt Load 5 Save Edit BH Device 84 Contig lt p nto S Settings Shortcut Operate Programmer Model 89 UPro Devicee Modet ATMEL 89551 e Auto Blank Read db Program Verify SIH UPro PROGIRAMIMIEIR lt Erase evice AT88551 endor ATMEL 4K Bytes Y Note Select 89 E UPro if programmer auto not detected Enriching Life through Knowledge B USER MANUAL 89 UPro page Step 72 Select Device By clicking Device button to bring device selection dialog After selecting inserted device click OK To select recently used devices you can click on down arrow amp select File Edit Device Operate Ty DEVI C E i gt Load Save 5 Edit lt Device v a Config e Settings 9 Shortcut Operate Programmer Model 89 UPro Mode ATMEL 89551 e Auto lank dp Program vei Protect Hardware Search Type Device AT24C 01 exis AT24C G1 SO01C8 MCU MPU AT24C02 EEPROM FLASH NVRA RT24C828S01C8 M AT24C 64 AT24C G4 SO01C8 AT24C 68 AT24C 08 01 8 128616 EPROM PROM Serial EEPROM PLD GAL CPLD SRAM DRAM AT24C16 S01C8 AT240164 AT24C164 S01C8 725032 AT24C32 S01C8 AT24C64 AT24C64 S01C8 AT89C1651 AT89C1651 S01C26 AT89C2651 AT89C2651 S01C26 AT89C4651 S Erase
8. heck if loaded file content matches with device content d Program e Protect Program config options to device E e Erase Erase the device Verity lt gt Protect lt Erase ov Enriching Life through Knowledge Enriching Life through Knowledge HEleSof p Dany Development System ES US X DISCLAIMER This product is owned by the EleSof are protected by copyright law Therefore this manual is to be treated as any other copyright material No part of this manual including product amp software described herein may be reproduces store in a retrieval system translated or transmitted in any form or by any means without the prior written permission of EleSof The manual PDF edition can be printed for private or local use but not for distribution Any modification of this manual 1s prohibited EleSof provides this manual as 1s without warranty of any kind either expressed or implied including but not limited to the implied warranties or condition of merchantability or fitness for a particular purpose Elesof shall assume no responsibility or liability for any errors omissions amp inaccuracies that may appear in this manual In no event shall EleSof its directors officers employees or distributors be liable for any indirect specific incidental or consequential damages including damages for loss of business profits amp business information business interruption or any other pecuniary
9. loss arising out of the use of this manual or product even if EleSof has been advised of the possibility of such damages EleSof reserves the right to change information contained in this manual at any time without prior notice 1f necessary All the product tools amp corporate names appearing in this kit amp manual may or may not registered trademarks or copyright of their respective company amp are only used to identification or explanation amp to the owners benefit with no intent to infringe Visit www elesof com www projectsmaker com Enriching Life Knowledge Development System HIGH RISK ACTIVITIES The products of EleSof are not fault tolerant nor designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance such as the operation of nuclear facilities aircraft navigation or communication system air traffic control direct life support machines or weapons system which the failure of software could lead directly to death personal injury or severe physical or environment damage High Risk Activities EleSof amp its suppliers specifically disclaim any expressed or implied warranty of fitness for High Risk Activities Copyright 2010 2012 by EleSof T echnologies All right reserved www elesof com www projectsmaker com Enriching Life Knowledge 3EleSof f Development System
10. opying To set lock option for selected device click on config ModeO is no lock and other modes are other lock options You can see device datasheet as to which config lock bit will be suitable in your application Once you set a config for particular device it is stored and it is not required to set again Next time you program a particular device same config will be used to load in to device during Auto process File Edit Device Operate Hardware X load v L ave dj a2 Dovid 8 Config 1 85 Settings Shortcut Operate Programmer Model 89 UPro Device Mode ATMEL AT 89S51 amp Auto Program verity gy Protect Device 4189551 Vendor ATMEL Size 4K Bytes Adapter None Failure Online Mode Success Mode 1 No memory lock features enabled 181 0 LB2 U LB3 U Mode 2 MOVC disabled LB1 P LB2 U LB3 L Mode 3 same as mode 2 verify disabled LB1 P LB2 P LB3 U Mode 4 same as mode 3 extemal execution disabled LB1 P LE2 P LB3 P SIH UPro PROGRAMME R Note Before Selection Locking mode Protection Mode ensure your self ov Enriching Life through Knowledge B USER MANUAL 89 UPro IGS Copying from one device to another You may wish to copy content from one programmed IC to another For this process first select device and Insert Mas
11. rk drive Disconnect network drive Create shartcut Delete Rename Be Advanced system Properties daos COM amp LPT Update Driver Software 7 Po Ports COM amp LPT Disable zu EleSof USB to Serial Bridge COMM Uninstall as m Intel R Active Management Technol Li Processors GIHE UPro PROGIRAIMIMILEIR Scan for hardware changes Properties Enriching Life through Knowledge B USER MANUAL GrP SiEleSof 894E UPro p IGS page N Advanced Settings for COMI Use FIFO buffers requires 16550 compatible UART Select lower settings to comect connection problems Select higher settings for faster performance Receive Butter Low 1 Transmit Buffer Low 1 conte COM Port Number 797 Ports COM amp LPT 737 EleSof USB to Serial Bridge COMI S m Intel R Active Management Technol GIHE UPro PROGIRAMIMILEIR Enriching Life through Knowledge B USER CELULITA LITTA MANUAL o SiEleSof 89 UPro IGS page amp 9 ICs Placement Below images shows ICs placement over ZIF Socket of 89 E UPro for programming SST ATMEI WINBOND Flashing Steps TO flash ICs which supported by 89 E UPro follow the steps mentioned below Step 1 Connect 89 E UPro amp Run Flashing Software 89 E UPro Connect 89 E UPro with PC USB port through A B USB cable amp run Flashing Softw
12. ter IC from which you want to copy program then click on READ button It will read device memory to buffer If you wish to see what content was read you can click on EDIT button File Edit Device Operat Hardware H Save Edit E Device v 23 Config In ee Settings Shortcut Operate Programmer Model 89 UPro Mode ATMEL A4T89851 e Auto Blank Read i x CE verity pp Protect Erase Device 4189551 Vendor ATMEL Sie 4K Bytes Adapter None Failure File Online Mode Success To save this memory as HEX file you can click on SAVE button If your master IC is locked it will show memory as OxFF means its content cannot be read Once you have saved file from master you can use this file to load into new microcontrollers Other software options Normally you will use Auto method in repeated programming task Auto method will automatically do Erase Blank Check Program Verify amp Protect We have given other options like Blank Read Program Verify Protect amp Erase that can be used individually if you wish Shortcut Operate SIH UPro PROGIRAMIMIEIR Following are methods you can use eG l ura e Auto Automatically do all process below as required to load file into device lt e e Blank Check if device is blank a e Read Read content of inserted device into buffer 4 sis e Program Load the content of file into device e Verify C

Download Pdf Manuals

image

Related Search

Related Contents

Étiquette du produit ( PDF, 164 Ko)  Hercules Universal DJ manual PDF  Avaya IP Phone 2002 User Guide  GE EL Series Installation Guide  19 SEPTEMBRE 2014 - La destruction de l`economie  Hunter Engineering 6698-T Specification Sheet  Manual del usuario Beafon s33  IDEALARC® DC600 VRD  disposizioni sanitarie generali – ambiente  

Copyright © All rights reserved.
Failed to retrieve file