RD8250 User Manual - OMEGA Engineering
Contents
1. TABLE OF CONTENTS 10 2 2 1 8 Using the screwdriver tighten both screws so that the Recorder is held firmly in place Do not over tighten to avoid stripping the threads D DC Power Connector a ee Relay Outputs Digital Input ce Analog Inputs Locking Bar 2 Temperature BC Retaining Screw 2 Compensator Figure 2 2 Rear View Installation 2 3 CONNECTION 2 3 1 Power Connections WARNING NOTE The Recorder is designed to be panel mounted and power should be considered to be permanently connected Disconnection from the supply must be possible via a customer supplied switch or circuit breaker This disconnection device must be included in the panel installation and should be clearly marked in close proximity to the Recorder and easily accessible to the operator THE RECORDER IS DESIGNED TO OPERATE ON 9 Vdc DO NOT CONNECT AC POWER DIRECTLY TO THE UNIT AT ANY TIME The power connector is located on the rear panel in the top left corner There are two voltage options available for the recorder the standard is 9Vdc which is used with an external universal AC Mains power supply The external wall power supply is a high efficiency switcher that will work from 100 to 240 Volts AC 50 60 Hz The other power option is an isolated 12 to 24Vdc input for use with an external DC power supply The power supply option is marked with a dot in a square on a label above the power
2. The following is a list of the characters are available any place text can be entered The list will start with the A character underlined and the UP and DOWN arrows move through the list in order left to right The characters in shadow are NOT legal for file names N w D a Ei s NAN Aru cz2m lt z so0 o 7 2 CG ao lt 53 soal vs o xvr vo lt a ovp A N Nso NG D APPENDIX B ERROR AND INFORMATION MESSAGES The following messages appear on the Graphics screen as a result of the following suggested solutions appear in italics ACCESS DENIED An incorrect password was entered while attempting to gain access to a password protected function Find someone who has the right password BAD FILENAME The filename entered does not meet the DOS requirement Use A to Z and 0 to 9 without spaces 8 characters max Re enter the name CARD ABSENT Failed attempt to read from viewing or write to recording a memory card which is not present nsert a card CARD ACCESS ERROR Failed attempt to read or write a memory card due to file data corruption Format and erase card data will be lost CARD FULL Failed attempt to write to a memory card which is filled to capacity Exchange card with a new one that has spare capacity ENTER CURRENT PASSWORD You have attempted to access a password protected function and must enter the password to continue Enter current password ENTRIES MISMATCH This time password did not match
3. 5 1 BATTERY BACKUP OPTION 5 2 ETHERNET OPTION 5 3 CALIBRATION 5 3 1 Basic Calibration 5 3 2 Examples 5 4 SPECIFICATIONS APPENDICES APPENDIX A UNITS LABEL CHARACTERS APPENDIX B ERROR AND INFORMATION MESSAGES APPENDIX C MASTER RESET APPENDIX D RE PROGRAMMING FIRMWARE APPENDIX E TOTALIZER COUNTER FUNCTIONS APPENDIX F ALTERNATE LANGUAGE FILES SAFEGUARDS AND PRECAUTIONS Read and follow all instructions in this manual carefully and retain this manual for future reference Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated This instrument is not user serviceable For technical assistance contact the sales organization from which you purchased the product WEEE NOTICE In order to comply with EU Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This product may contain material which could be hazardous to human health and the environment DO NOT DISPOSE of this product as unsorted municipal waste This product needs to be RECYCLED in accordance with local regulations contact your local authorities for more information This product may be returnable to your distributor for recycling contact the distributor for details Para obedecer con EU Directiva 2002 96 EC en el Desecho el Equipo El ctrico y Electr nico Este producto puede contener la materia que podr a ser la salud humana pe
4. The instrument is intended to operate in the following environment Indoor Use Only Installation Category Il per IEC 664 Pollution Degree Level Il per EC61010 1 Temperature 10 C to 50 C operating per IEC61010 1 Humidity Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Recorder Power 9 0 0 5V dc 5VA unless indicated otherwise on the unit AC Power Requirement External adapter 100 240 Vac 50 60 Hz NOTE The recorder is designed to be panel mounted and as such should be considered as permanently connected Disconnection from the supply must be possible via a customer sup plied switch or circuit breaker This disconnection device must be included in the panel installation and should be clearly marked it must be in close proximity to the Recorder and eas ily accessible to the operator TABLE OF CONTENTS NOTE In order to fully comply with the CE EMC Directive 89 336 EEC connections to the recorder should not exceed 3m 9 8ft without adding additional filtering The Recorder fits in a standard Ya DIN panel cutout of 92 x 92 mm 3 62 x 3 62 in and requires 140mm 7 5 inches panel depth not including space for power and input source cable The thickness of the panel is immaterial but panels thicker than 125 inch will require that the locking bars be cut down Actual dimensions are shown below in Figure 2 1 0 41 D o B55 10 41 11
5. Frystatska 184 733 01 Karving Czech Republic Tel 420 0 59 6311899 FAX 420 0 59 6311114 Toll Free 0800 1 66342 e mail info omegashop cz 11 rue Jacques Cartier 78280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom Tel 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales omega co uk It is the policy of OMEGA to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications TABLE OF CONTENTS INTRODUCTION 1 0 2 0 3 0 a ech sch m m zl OO OO P Gab CHART SPEED TO SAMPLE SPEED REVIEWING DATA ZOOMING AND CONDITIONING DATA CUSTOMIZING TR
6. Should there be any changes in the menuing or other messages as a result of the new FIRMWARE only the still existing message strings will retain the alternate language equivalents English items removed will automatically omit the alternate language variation New English items will not already have an alternate language variation and will remain in English when displayed The user can check for this by reviewing all the menus manually An easier way is to use SAVE LANG to make a new file and then visually inspect that for TABLE OF CONTENTS 40 missing items to the right of the asterisks The missing items can be added or not as the user requires APPENDIX E TOTALIZER COUNTER FUNCTIONS To use the TOTALIZER FUNCTION go to MENU gt ADVANCED SETUP gt CH Aor B SETUP gt INPUT TYPE and set the input channel up as described in Section 4 1 From the MENU gt ADVANCED SETUP gt CH Aor B SETUP gt FILTER pane select Totalizer From this pane use the UP and Down Arrow keys to select your range and reset options Calculate the highest number your total will be without going over range and use the lowest possible full scale range for best resolution This will provide the best accuracy in your results The maximum number of counts is 8000 in any x1 range 800 000 in a xk range and 8 million in a xm range It is also helpful to reset the Totalizers as often as possible as any errors are accumulated over time There is less accumulated error in a mo
7. Up Arrow A or Down Arrow Y button to highlight CURSOR ID and then press the MENU button again The Menu will vanish revealing the Graphics screen and a single data cursor against the right edge of the display area Note The Cursor ID mode will not activate if the Trend is compressed The screen will be in the HOLD mode and the data window at the top of the screen and time date stamp at the lower right will show the values of the samples under the data cursor The status line will show the highlighted DI to indicate that the data and timestamp is that of the data under the cursor and not real time data Using the Left al or Right gt buttons the user can move the data cursor to the point of interest The data window at the bottom of the screen will show the time and date of the sample and the digital readings at the top of the screen A and B in dual channel units show the absolute value Note that at the extremities of the data the cursor hits an end point and then the data scrolls beneath it This method can be used to accurately identify unique points on the graphics display no matter how busy the traces appear To return to normal real time mode press the MENU button Note that entering the Cursor ID mode does not affect the real time acquisition of data 3 5 6 VIEW FILE The user can view data from files other than the one currently being recorded The View File option allows the user to view previously recorded data on the data
8. and forth at anytime Notes The language currently selected for use does not affect what s written to the file however the words in the menu mentioned above may appear onscreen as the alternate language equivalents There are no restrictions on actual case and how the style of the strings can vary but the menu strings have to be 14 characters or less Others have to fit the screen using a single line of text Leading spaces with the user entered text will appear in the messages and will generally waste space They should be avoided Note that depending on the editor being used and the length of the English text the asterisk may appear to fall in different positions from line to line Resist the temptation to line them up to avoid damaging the text to the left of that asterisk The user does not have to enter in an alternate phrase for every line in the file The English version will automatically be substituted for those omitted In fact an alternate English version could be substituted by only changing a few of the lines to suit a user s preferences It is recommended to keep backup copies of language LAN files More alternate languages can be created and saved in additional LAN files for use one at a time TABLE OF CONTENTS 42 WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s Warranty adds an
9. calibration value require an additional span calibration to correct for the internal current source each channel CURRENTS which are derived from the Hi Volts calibration value require an additional span calibration to correct for the external resistor Customer supplied each channel FREQ and SPEED requires only a time base calibration shared for both channels In general to calibrate an analog input first set the specific channel to an input type in the ADVANCED SETUP MENU CHANNEL SETUP INPUT TYPE see Section 4 1 Once an input type has been chosen select CALIBRATION see Section 4 1 Do not change the units from the default values set when that range is selected i e leave volts as volts and current as current Apply a zero value to the input and using the up A and down arrow buttons adjust the OFFSET until the onscreen indications shows zero Apply a high value to the same input and using the up A and down arrow buttons adjust the SPAN until the onscreen indication agrees with the input Note use an input value slightly less than the full scale value to prevent an overrange indication Repeat for all input types and channels to be used if not all of them 5 3 2 Examples Volts Should be done for the Lo Volts 250mV 1 25V 2 50V ranges and Hi Volts 5 00V 12 5V 25 0V ranges using the 250mV and 5 00 volt ranges respectively For each channel individually set the input for 250mV and go to C
10. connector as shown in Figure 2 3 Check the unit to ensure that the power and inputs are as expected 11 e 9Ude 12 24 Sie Figure 2 3 TABLE OF CONTENTS Before connecting any power or inputs to the unit ensure that all signal wires and power cables are at zero voltage The DC power is applied to the unit via a three way screw terminal connector The power supply is supplied with two tinned leads the positive lead is identified by the RED shroud over the wire The third connection is for system GROUND You will require a small flat head screwdriver Connect the power and signal wires accordingly noting carefully all polarities Ensure that the unit is properly grounded to a suitable ground within the cabinet Loosen the screws on the terminal block and insert the exposed conductor cable from the power supply below the screws under the metal plate Ensure that the insulation is flush with the terminal block If it is too long remove the cable trim and reinsert Tighten the screw to firmly hold the cable Ensure the ground wire is connected and properly grounded at the other end If you are not using the supplied wall power supply follow the same procedure carefully identifying the positive supply line The unit is protected against reverse polarity but not against substantial over voltage 2 3 2 Input Signal Connections The maximum input on any input channel is 25 Volts DC Voltages higher than this may permanently damage the
11. last time password when setting up Try it again only more slowly ENTRY ERROR An illegal number of keystrokes were entered while entering the password Try it again only more slowly TABLE OF CONTENTS 39 FILE NOT FOUND Failed attempt to read a data file or configuration file due to the fact that no such file exists on the memory card Get the correct card FORMAT CARD Card is incompatible or unformatted Requires formatting OVERWRITE CONFIG FILE A config file already exists on the memory card Writing to the card will overwrite this existing file The unit is checking user intent Press the UP ARROW key to overwrite the existing file any other key to exit STOP RECORDING FIRST The function you are trying to perform cannot be done while the unit is in record mode Stop recording and try again TEST FAIL The card has errors on it and did not pass the card test Try reformatting the card or swap the card APPENDIX C MASTER RESET The master reset is used to restore all factory defaults to the unit It is used in the unlikely event of the unit losing or corrupting the contents of its nonvolatile memory All user configurations will be lost To reset the unit to the factory defaults hold the two outer keypad buttons down simultaneously The DOWN and LEFT arrows while powering up the unit Wait two to three seconds and then release APPENDIX D RE PROGRAMMING FIRMWARE The operating firmware in the unit is programmed int
12. low lt 1 0Vde high gt 3 0Vdce lt 12Vdc Pulse width 10usec minimum gt 100k up to 100 samples sec per channel y mx b average hi peak lo peak TABLE OF CONTENTS 37 Media Display Display Modes User Interface Clock Relay Output Opto isolated Input Audible Dimensions Environmental Certification Compact Flash to 2 GB LCD Graphics 160 x 80 pixels black FSTN with White LED backlight User controlled Backlight level and Contrast adjust electronic Trending Horizontal Large Dual Digital Readout Mixed Mode 5 buttons keypad with 2 Function operation Internal battery backed clock with auto leap year and daylight savings Two alarm outputs 30V 0 5A Form A relays One input 5 to 12Vdc operation 10mA typical Internal buzzer tones Front panel 96mm x 96mm 1 4 DIN x 152mm 3 78 x 3 78 x 6 inches Indoor Use Only Installation Category II per IEC 664 Pollution Degree Level Il per EC61010 1 Altitude up to 2 000 m Temperature 10 C to 50 C operating per IEC61010 1 Humidity Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C CE EN61326 EMI EMC ENG61010 1 Safety UL and cUL Power Supply Optional Communications USB Ethernet Front panel USB 2 0 slave port for data transfer and configuration 10 100 Ethernet This space intentionally left blank TABLE OF CONTENTS 38 APPENDIX A UNITS LABEL CHARACTERS
13. not disrupt the recording procedure provided that the file you are viewing is on the same memory card as the one you are recording on OR you do not exceed the buffer storage time on the recorder if you are using another memory card 3 8 ENTERING DATA When adjusting or entering values you have to use the V A gt a button keys Alphanumeric Values The b gt key moves the cursor to the right to select the character to be edited It will wrap around from right to left The W A change the character as shown in Appendix A The MENU button accepts the data and exits and the lt key escapes Numeric Values work a little differently the value increments and decrements according to the up A or W down keys Single presses increment or decrement the value by 1 If the button is pressed and held down the value will increment or decrement in steps of 10 If the MENU button is held down and the A or WV button is pressed and held down the value increments or decrements by 100 The MENU button accepts the data and exits and the 4 key escapes This space intentionally left blank TABLE OF CONTENTS 24 3 9 TOP LEVEL MENU OVERVIEW Top Level bevet Function EXIT Exits from Menu ALARM Resets any Alarms Note if Alarm is still RESET active it will set again Auto exits menu RESET TOTAL Reset Totalizers CHAN A Reset Channel A Totalizer CHAN B Reset Channel B Totalizer BOTH Reset Channel A and B Accumulators Enter Password if set
14. scale value disappears x1 mode TABLE OF CONTENTS 19 3 5 MENU MODE At any time when in normal view mode pressing the MENU button will UT Lat bring up the user menu as shown to the right Note that the menu pops up over the graphics display The unit continues to record and EXIT will not lose data There is also a time out option that will return a ALARM RESET menu display back to a graphic display after a period of inactivity RESET TOTAL Refer to Advanced Setup DISPLAY MENU TIMEOUT Ge SEH When the menu is active the Left Arrow lt and Right Arrow ee cine gt buttons act as ESCAPE keys to return to a previous level INFO without activating any function SAMPLE RATE The user moves about the menu using the Up Arrow A and Down Ge Arrow buttons The current selection is always highlighted in DISPLAY ADJ reverse To select a function simply move to it with the A and RW buttons and then press the MENU button once To go back a level without activating any function simply press the lt or gt buttons Note that the menu has more options than can be displayed at once on the screen When a selection gets to the top or bottom of the menu list the list will scroll until the last entry is reached then wrap around Pressing and holding the A and V buttons will activate an Auto Repeat function and cause the highlight bar to scroll automatically The menu has multiple levels An option with a secon
15. the name entered in the recorder with LAN suffixed The contents of the file will appear in the following format EXIT ENTER ALARM RESET FALSE ALARM RESET TOTAL RESET ALL RECORD MODE CURSOR ID VIEW FILE All of the modifiable message strings will appear in the file The general format of each string is STRING tab tab asterisk newline 41 If there are already any alternate language strings present in the recorder they will appear farther to the right on the line after the asterisk on the same line as the English language phrase it s associated with The user will optionally enter more or modify existing text to the right of the asterisk The asterisk has to remain present along with all of the text and tab characters to the left of that asterisk for the new text to be registered properly with the recorder When the user has made the desired changes he then loads the newly edited LAN file into the recorder using the LOAD LANG menu command This causes the alternate language to be loaded into the recorder and saved in the Flash memory Wait for the transient message DONE to appear This process may take up to a minute to complete Occasional blinking of the Red LED will signify accesses to the card as it proceeds Finally the user will select which of the 2 languages will be made to appear onscreen This selection will normally be remembered through power interruptions however the user can change the selection back
16. the name for recorded files up to 8 Characters Use V AP keys 4 key to escape Use MENU key to Save and Exit SAVE CONFIG Save Configuration Enter Config File Name up to 8 Characters Use V AP keys 4 key to escape Press MENU to save and exit LOAD CONFIG Load Configuration Unit will show list of files Use A to select lt key to escape MENU to select and load Unit will restart on successful load TEST CARD This is a non destructive test to check the card ERASE CARD Erase File Unit will show list of files on card Use YA to select lt key to escape MENU to select and erase This will FORMAT the card for use in the recorder ALL DATA WILL BE DESTROYED FORMAT CARD TABLE OF CONTENTS 29 4 6 CLOCK This option allows the user to set the time and date and determine what is displayed for time on the bottom right of the display Use the Up Arrow 4 or Down Arrow buttons to scroll and highlight CLOCK and press the MENU button The menu options are shown below TIME OF DAY Select Time Display as Real Time Clock 24 HR Select Time Display as 24 hour or 12 hour AM PM AUTO DST Select to enable Daylight Saving Time adjust TIME ZONE Allow for international time correction Actual time recorded is GMT This corrects for current local time so data is global MM DD YY Select date format as Month Day Year DD MM YY Select Date format as Day Month Year SAMPLE TIME Show time of actual last sample DE
17. the standard language to annotate the menus and other interactive messages It also supports an optionally user entered second language This second language can be entered into a file using a common text editor such as Windows Notepad That file is subsequently loaded in from a CF card and becomes available along with the still available original English See Appendix F for detail The ALTernate LANGuage menu option allows the user to select the Alternate Language The user can toggle between the languages selecting English or Other Language Use the Up Arrow A or Down Arrow buttons to scroll and highlight ALT LANG and press the MENU button The menu options are shown below The Menuing functions as follows 4 12 UNIT TAG The unit tag is used to identify the recorder It is saved to the data file when recording and can be read back by the analyzing software It is also displayed on the top of the main menu when the MENU button is pressed for the first time It can be a maximum of 15 characters Select this option then use the VW AP keys to adjust and the lt key to escape or the MENU key to Save and Exit See Entering Data above for details 4 13 COMMS This option allows the user to set the IP Address Subnet Mask and Default Gateway for the Ethernet Option See below Use the lt keys to select the digit to change Indicated by 123 and WA to change it Use the MENU to accept or to escape The menu options are shown belo
18. then press MENU OFF Stop Recording ON Start Recording RECORD MODE TRIGGERED NAME FILE SAVE CONFIG LOAD CONFIG CURSOR ID VIEW FILE SAMPLE RATE 100 S sec to 10 sec S PASSWORD ADV SETUP DISPLAY ADJ Arm Triggered Recording An External Event will start and stop recording as programmed Enter the name for recorded files up to 8 Characters Use V AP keys lt key to escape clear or list directory Use MENU key to Save and Exit Save Configuration Enter Config File Name up to 8 Characters Use V AP keys 4 key to escape clear or list directory Press MENU to save and exit Load Configuration Enter Config File Name up to 8 Characters Use V AP keys lt key to escape clear or list directory Press MENU to save and exit Unit will restart on successful load Puts chart in HOLD mode and places cursor on screen Use lt gt keys to move cursor and read trend values at top Press MENU key to exit this mode Select an existing file on the CARD to browse Enter File Name up to 8 Characters Use V AP keys lt key to escape clear or list directory Press MENU to browse Pops up window show memory card status Includes capacity full time remaining Select again to remove window Displays Firmware Revision and MAC Address on Trend Window Use A key to return to trend Enter Password if set then press MENU Select sample rate from 100 Samples sec to 10 min Sample Use YA keys to navigate lt k
19. unit Ensure the unit is powered down before connecting any inputs There are two universal analog inputs Channel A and Channel B Each is programmed independently of the other Inputs can be voltage or current 50mA max using an external shunt thermocouples RTDs or TTL compatible pulse inputs Isolation is provided between inputs and the rest of the system The channels are not isolated from each other Connection detail for the various inputs is shown in Figure 2 4 Ext Voltage Current RPM Sensor VO I IN IN VO I IN IN VO I IN IN Blue Black R Brown Oo V Thermocouple RTD 3 Wire VO I IN IN VO I IN IN J RTD Figure 2 4 Connection Detail When connecting the signal wires keep polarities correct The screw terminals are marked on the rear panel there are four connections per channel The high or positive TABLE OF CONTENTS 12 signal marked IN and a low or common signal marked IN The terminal marked Vo is the Auxiliary voltage output used to drive external sensors at 5Vde and a maximum of 50mA The terminal marked I is the 1mA current required for RTDs or resistors Any screen or shield often the braided wire should connect directly to the system ground
20. 0mV for the same channel as described above Then switch to RTD range Select NOMINAL to copy the volts calibration to RTD range The recorder is now calibrated for ideal sensors and internal current source Refine the calibration by applying an accurately known resistance for a given temperature you may need resistance to RTD tables Adjust the SPAN until the correct temperature is displayed this corrects for the internal current source Frequency RPM or Hz Apply a calibrated frequency input near the high end of the selected input range of either channel Adjust SPAN until the indicated value is correct There is no applicable OFFSET adjustment to be made Recommended procedure for full initial calibration in this order Calibrate 250 mV range both channels using a calibrated source Calibrate 5 00 V range both channels using a calibrated source Calibrate any T C range both channels using the NOMINAL method Calibrate any RTD range both channels using NOMINAL method Calibrate any current range both channels using NOMINAL method Calibrate any Tach range either channel using a calibrated signal source NOTES As with other numeric editing the rate that a calibration value is adjusted accelerates with the length of time the button is pressed Calibrating either channel for tachometry calibrates both channels and does not have to be repeated for each channel as they use the same base counter Additionally there
21. 32 46 3 78 96 00 jy 3 78 _ 0 15 96 00 3 81 4 07 103 38 Figure 2 1 Recorder Dimensions WARNING Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated 2 2 1 Panel Mounting The Recorder should be mounted in a vertical panel to ensure proper operation Ensure you have the proper clearances and proceed as follows 2 2 1 1 Cut a panel opening 92 mm x 92 mm 3 62 x 3 62 in 2 2 1 2 Remove any packaging material from the Recorder Always handle the unit carefully to avoid damaging the LCD display or scratching the display surface 2 2 1 3 Remove the locking bars from the Recorder enclosure by removing the captivating screws 2 2 1 4 Insert the Recorder rear end first through to front of the panel opening 2 2 1 5 With the Recorder held firmly in place against the panel install one of the locking bar assemblies from the rear by sliding the locking bar tongue into the groove on the side of the Recorder enclosure as shown in Figure 2 2 2 2 1 6 Insert the retaining screw into the rear of the groove Using a Phillips screwdriver tighten the screw until the locking bar is just pressing against the panel 2 2 1 7 Install the other locking bar assembly into the groove on the opposite side of the Recorder enclosure and tighten as before
22. Down Arrow button to make a selection and then press the MENU button The active selection is indicated by a V to the left of the option If you are using the alarms or external input to control the recording select TRIGGERED for triggered operation OFF and ON will always stop or start a recording irrespective of the state of any of the record triggers Refer to Event Triggering TABLE OF CONTENTS 20 The RECORD MODE menu option may be password protected Before selecting ON or TRIGGERED to begin a recording ensure that a Memory Card is in place and that there is sufficient space available to contain your new data Refer to CARD STATUS below 4 4 To return to the graphic screen press either the Left 4 or Right kl Arrow button For further details on other options under RECORD MODE refer to ADV SETUP DATA CARD Note While recording the recorder automatically switches to OFF when a card is removed or if it is not present when power is applied This will require a manual restart of the recording when a new card is inserted If the card remains in the slot while power is removed the recorder restores the recording state it was in when the power was interrupted 3 5 5 CURSOR ID The Cursor ID mode enables the user to accurately pinpoint the time and amplitude of any sample in the graphics window The unit has to be in the full graphic mode for this option to work To enable this function press the MENU button use the
23. E STAMP NONE No imprint of TIME or DATE on TREND display TIME ONLY TIME amp DATE TIME imprints on TREND display TIME and DATE imprint on TREND display TOP Set location of Time amp Date imprint to TOP of TREND MIDDLE Set location of Time amp Date imprint to MIDDLE of TREND BOTTOM NEVER Set location of Time amp Date imprint to BOTTOM of TREND MENU will never Collape and revert to display mode 30 SEC to Choose MENU TIMEOUT from 30 seconds to 30 Minutes Menu will revert back to normal display 30 MINUTES LIGHT TIMEOUT NEVER BackLight will never shut off 30 SEC to 30 MINUTES Choose time to backlight shut off from 30 seconds to 30 Minutes after inactivity Select to turn back light off in battery mode to save Es power battery is optional Set CHAN A TREND line to SOLID __ DOT Set TREND line to a series of DOTS DASH Set TREND line to a series of DASHES DOT DASH Set TREND line to a series of DOTS and DASHES Set CHAN B TREND lines as above Same as Top Level Menu option see above DISPLAY ADJ 4 5 DATACARD This option contains duplicate menu items to those found in the RECORD MODE menu In addition it enables the user to test the card and format it for use recommended Use the Up Arrow A or Down Arrow buttons to scroll and highlight DATA CARD and press the MENU button The menu options are shown below NAME FILE Enter
24. FAULT Select default setup Time of Day 12 hour format DST on Date format is MM DD YY 4 7 BEEPER This option allows the user to have various events sound the beeper Alarms message boxes and key presses The tone of the beeper may also be programmed Use the Up Arrow 4 or Down Arrow buttons to scroll and highlight BEEPER and press the MENU button The menu options are shown below OFF BEEP on ALARMS turned off if checked ALARM 1 Beep on Alarm 1 ALARM 2 Beep on Alarm 2 ALARM 3 Beep on Alarm 3 ALARM 4 Beep on Alarm 4 EXT INPUT Beep on External Input ted is a continu Select Alarm TONE A add warbling effect Select Alarm TONE B add short silence between tones Select Alarm TONE C add longer silence between tones Select Alarm TONE D add long silence between tones TABLE OF CONTENTS 30 4 8 SAMPLE TRIGGER This option allows the user to program what will trigger a change of sample rate in the displayed or recorded data Use the Up Arrow 4 or Down Arrow buttons to scroll and highlight SAMPLE TRIG and press the MENU button The menu options are shown below g Note that if an event is selected to change the sample rate when exiting the menu the sample rate menu will be displayed Use the Up Arrow A or Down Arrow buttons to scroll and highlight the new sample speed and press the MENU button to select and the Left Arrow 4 button to exit OFF No Sample Rate change if c
25. G DATA TREND VIEWING In order to view data trends it is often necessary to pack more data onto the screen than is normally visible in real time To compress the data press and hold the MENU 2nd Function key and then press the COMPRESS b key Each time this key is pressed the amount of data on the screen will double up to a maximum of 32 times equivalent to 5 TABLE OF CONTENTS 18 sequential key presses Once compressed data can be rewound and fast forwarded as described in the previous section The data can be expanded back after being compressed by pressing and holding the MENU key and then pressing the EXPAND 40 button Note that compression displays peak values both high and low Thus even though data is compressed all amplitude information is present on the display At compressions of 16 times or greater the redraw time of data on the screen slows down due to the large amounts of data that must be manipulated At any stage during the compression or expansion process the screen can be restored to current or real time display by pressing the MENU button SE When the data on screen is compressed a appears on the status line to indicate that the compress mode is active 3 4 ZOOMING DATA AMPLIFICATION As a result of the small display area available it is not always possible to see small changes in amplitude of the recorded signals even though the resolution of the internal converters can measure it To overcome this p
26. G RELAY CONTACTS The relay contacts are rated for AC or DC operation Maximum recommended voltage 30 Volts Each relay has a set of potential free contacts There is no polarity to the terminals it is a normally open contact that closes in alarm condition These contacts are internally suppressed for EMI RFI and High Voltage transients resulting from inductive loads The relays may be programmed as fail safe which means they are energized in the off condition This way if the power should fail the relays will open into the alarm condition See note below 2 3 4 Digital Input The digital input is optically isolated and is activated by an external dc supply of 5 to 12Vdc at 20mA The input is via the DIGITAL INPUT and terminals The connection is the COMMON for the external input while the is the input for the positive voltage The digital input may be used as an External Trigger to stop or start recording or may be used to change the sampling speed Thus the unit can be set to record only when a conveyor is running for example The External Trigger may also be linked internally to the optional Relay Output This could be used as a remote record active indicator Refer to Sections on Relay setup and External Input setup Note In order to fully comply with the CE EMC Directive 89 336 EEC cables to the relay output and digital input should be looped through a ferrite Type Steward 28R2025 0R0 or similar close to the ter
27. IGGERING THE GRAPHICS LCD DISPLAY OTHER GRAPHIC MODES INSTALLATION AND SETUP 2 1 2 2 2 3 2 4 2 6 UNPACKING 2 1 1 Initial Inspection 2 1 2 Unpacking Procedure 2 1 3 Detected Damage 2 1 4 Equipment Return 2 1 5 Storage INSTALLATION 2 2 1 Panel Mounting CONNECTION 2 3 1 Power Connections 2 3 2 Input Signal Connections 2 3 3 Relay Output Connections 2 3 4 Digital Input 2 3 5 USB Port Option 2 3 6 Ethernet Port Option 2 3 7 Isolated DC input Option 2 3 8 Cleaning INPUT SCALING ALARMS 2 5 1 Alarm Types 2 5 2 Setting Alarms 2 5 3 Alarm Indication MEMORY CARDS 2 6 1 Care of the Data Cards 2 6 2 Card Storage Capacity and Data Type BASIC OPERATING INSTRUCTIONS BASIC MODE OF OPERATION VIEWING HISTORIC DATA COMPRESSING AND EXPANDING DATA TREND VIEWING ZOOMING DATA AMPLIFICATION MENU MODE 3 5 1 EXIT 3 5 2 ALARM RESET 3 5 3 RESET TOTAL 3 5 4 RECORD MODE 3 5 5 CURSOR ID 3 5 6 VIEW FILE 3 5 7 CARD STATUS 3 5 8 INFO 3 5 9 SAMPLE RATE 3 5 10 PASSWORD PROTECTION 3 5 11 ADV SETUP ADVANCED SETUP See below 3 5 12 DISPLAY ADJ ADJUST 3 6 EVENT TRIGGERING 3 7 STATUS LINE INDICATORS 3 8 ENTERING VALUES 3 9 TOP LEVEL MENU 4 0 ADVANCED SETUP 41 CHANNEL SETUP 4 2 ALARMS 4 3 RELAYS 4 4 DISPLAY 4 5 DATA CARD 4 6 CLOCK 4 7 BEEPER 4 8 SAMPLE TRIGGER 4 9 RECORD TRIGGER 4 10 EXTERNAL INPUT 4 11 ALT LANGUAGE 4 12 UNIT TAG 4 13 COMMS 5 0 MISCELLANEOUS
28. LO PEAK min values over last sample interval TOTALIZER FAST FILT averages last 10 samples continuously CALIBRATION CAL ZERO If applicable Input zero and adjust V Afor zero MENU to accept CAL SPAN Input Max Span value and adjust Y Afor correct value MENU accepts CAL NOMIN Copies default calibration value CAL ALL 4 2 ALARMS This option is used to program the alarms There are four alarms and each is programmed independently Each alarm may be turned on or off and may be assigned to either channel Use the Up Arrow A or Down Arrow buttons to scroll and highlight ALARMS and press the MENU button The menu options are shown expanded below ALARM n N 1 2 3 4 ENABLE Turn Alarm 1 on or off M ENABLED is on HIGH Select if ALARM is HIGH LOW Same as HIGH Select if ALARM is LOW TABLE OF CONTENTS 27 HOLD OFF Use YA keys to enter time in seconds from Alarm till relays pull RESET DELAY Use V A keys to enter time in Se from RESET till relays drop LATCHING Toggle using PERUSE alarm latching LOCK OUT DEFAULT 4 3 RELAYS This option is used to program the physical relay outputs There are two relays and each is programmed independently The relays can be assigned to one or more ALARM events or the EXTernal INPUT Use the Up Arrow A or Down Arrow buttons to scroll and highlight RELAYS and press the MENU button The menu options are shown below OFF
29. MADE IN ol YEAR USA WARRANTY Ce e Shop online at omega con ZCSOMEGR omega com e mail info omega com ALS DSSS For latest product manuals omegamanual info 18509001 1509002 CERTIFIED IDSYRPM 4 sooo H CERTIFIED RI CORPORATE QUALITY CORPORATE QUALITY STAMFORD CT MANCHESTER UK RD8250 Recorder omega conY CEOMEGA OMEGAnet Online Service Internet e mail www omega com info omega com USA ISO 9001 Certified Canada Servicing North America One Omega Drive Box 4047 Stamford CT 06907 0047 Tel 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada Tel 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance USA and Canada Mexico Benelux Czech Republic France Germany Austria United Kingdom ISO 9002 Certified Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info omega com mx Servicing Europe Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 0 20 3472121 FAX 31 0 20 6434643 Toll Free in Benelux 0800 0993344 e mail sales omegaeng nl
30. RELAY is OFF ALARM 1 RELAY is tied to ALARM 1 ALARM 2 RELAY is tied to ALARM 2 ALARM 3 RELAY is tied to ALARM 3 ALARM 4 RELAY is tied to ALARM 4 EXT INPUT Relay is tied to EXTernal INPUT RELAY 2 same as RELAY 1 FAILSAFE Relays are energized in the non alarm condition NEITHER Select Neither relay as failsafe RELAY1 Select RELAY 1 as failsafe RELAY2 Select RELAY 2 as failsafe BOTH Select both relays as fail safe 4 4 DISPLAY This option is used to set up the display The Window Configuration allows the user to choose how to display data either as a trend or as digital values or as a combination of both The time stamp that appears on the trend can be customized the menu can be set to disappear and have the display revert back to normal and the backlight can be set to go off after a period of inactivity The backlight will restore on any event Use the Up Arrow A or Down Arrow buttons to scroll and highlight DISPLAY and press the MENU button The menu options are shown below Set display to full screen TREND both Channels DUAL DIGITAL Set display to DUAL DIGITAL readouts BOTTOM Set display to TREND in top half DIGITAL in TREND DIGITAL lower half CH B Set DIGITAL display to WHITE characters on DARK background ALARM BLINK DIGITAL value will blink when in alarm DIGITAL lt gt SWAP the position of dual digital windows INV DIGITAL TABLE OF CONTENTS 28 TIM
31. active when the input is less than the setpoint A latching alarm will remain set once activated and must be reset by the operator Note that the alarm condition should be removed before resetting the alarm or the alarm will activate and latch again A non latching alarm will set on alarm condition and automatically reset once the alarm condition is removed A differential known as hysteresis or deadband can be introduced so that once an alarm is set at the setpoint the input must go beyond the deadband before the alarm resets This prevents the output relays from chattering in borderline conditions The deadband is set in absolute units and adds to the setpoint in a low alarm or subtracts from the setpoint in a high alarm By way of example if the setpoint is 100 the hysteresis deadband is set to 5 and the alarm is a high type and non latching then the alarm will activate when the input exceeds 100 and will remain active until the input drops below 95 100 minus 5 Alternatively the user can set a reset delay from 1 to 255 seconds This delay must time out once an alarm condition has been removed before the alarm will reset to normal Lockout prevents an alarm from activating until the setpoint has been traversed in the opposite sense by the input For example if we were measuring pressure and had a low alarm set at 100 we may not wish the alarm to be active on start up when the pressure may be low or zero We really wish to monitor a low pr
32. additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibra tion improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components which wear are not warranted including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants onl
33. alibration Short the input and adjust the OFFSET until 0 is indicated Then apply a near full scale input so as to not over range the input say 240 mV on the 250 mV range and adjust the SPAN TABLE OF CONTENTS 35 Thermocouples preferred method First calibrate lo VOLTS range 250mV for the same channel as described above Then switch to Thermocouple range Select NOMINAL to copy the volts calibration to thermocouple range The recorder is now calibrated for ideal sensors Refine the calibration by either shorting the input you need to know the ambient temperature or attaching a thermocouple sensor or calibrator of the correct type for the selected range and then if necessary adjust the OFFSET until the correct temperature is displayed this corrects the ambient temperature sensor If there s a known high temperature source handy use that to fine tune the SPAN value Currents preferred method First calibrate Hi VOLTS range 5 00V for the same channel as described above Then switch to any CURRENT range Select NOMINAL to copy the volts calibration to the current range The recorder is now calibrated for ideal resistor 250 ohm Refine calibration for resistor and sensor current tolerances by attaching a 250 ohm 0 1 resistor and input sensor matching the selected range Apply low value inputs to adjust the OFFSET value and high value inputs to adjust the SPAN value RTDs preferred method First calibrate lo VOLTS range 25
34. and is used to shield the low level input signals from induced noise pick up Connect the signal wires to the terminal block in the manner described above Use wire of adequate gauge to carry the signal The mA input requires the use of an external 250 ohm shunt Check with supplier Thermocouples should be connected with thermocouple wire of the same type as the input the terminal block is the reference junction Connect any sheath or braid to the GROUND connection RTDs have an additional wire the current source which is connected to the terminal marked I See Figure 2 4 WARNING Unused inputs must have IN and IN commoned together CAUTION Never run signal and power or control wiring together in the same conduit This practice will prevent possible recording error due to induced signals between lines Route signal wires away from power wires at the rear panel NOTE Ground cable shields at one end only to eliminate the possibility of interference due to ground loop currents When grounded transducers are used the shield should be grounded at the sensor end only 2 3 3 Relay Output Connections WARNING To prevent the possibility of electrical shock use extreme caution when wiring contact output connections Hazardous potentials may exist on contact output terminals that are floating with respect to instrument ground WIRES FROM REMOTE SOURCES MAY CONTAIN DANGEROUS POTENTIALS ENSURE ALL POWER SOURCES ARE DISCONNECTED BEFORE WIRIN
35. card from the very first file through to the current data The display HAS TO BE IN THE FULL GRAPHIC MODE for this to work To view a file on the memory card press the MENU button use the Up Arrow A or Down Arrow button to highlight VIEW FILE and then press the MENU button again The current filename will be displayed To view historic data from this file simply press the MENU button To choose a different file on the memory card press the Left Arrow lt button twice to display a directory listing of all files on the card Then use the Up Arrow A or Down Arrow button to highlight the desired file and press the MENU button twice to select it When viewing from a file the status line will show a highlighted D to indicate that the data being viewed is from a File on the memory card All View Compress and Zoom functions work on the prerecorded file Use the Left lt or Right b buttons to move through the file Data will be presented as oldest samples first TABLE OF CONTENTS 21 To return to the current real time trend press the MENU button View File will automatically abort if the data card is removed 3 5 7 CARD STATUS To display the status of the memory card press the MENU button use the Up Arrow A or Down Arrow button to highlight CARD STATUS and then press the MENU button again A pop up window will be displayed showing information about the memory card including the size of the card the amount of spac
36. cked in a custom cardboard box to prevent damage during normal transit If damage to the shipping carton is evident ask the carrier s representative to be present when the instrument is unpacked 2 1 2 Unpacking Procedure To unpack your Recorder first remove the cardboard retainer and instrument from the shipping carton Check the box for the following contents The Recorder two locking bars two 6 32 x Yo screws AC power supply wall unit unless the unit is the isolated DC model and this manual 2 1 3 Detected Damage Remove the instrument from the plastic bag and check for damage if any Also check that the unit is as ordered If damage is detected after unpacking the instrument immediately report any damage to the shipping agent and re pack the instrument for return it to the factory as described in the following section 2 1 4 Equipment Return Before returning a damaged or malfunctioning instrument to the factory for repair contact the sales organization from which you purchased the instrument A Return Merchandise Authorization RMA number must be obtained from the factory before returning an instrument for any reason 2 1 5 Storage For prolonged storage before installation re pack the Recorder in the shipping container and store in a cool dry area We do not recommend storage of the Recorder for more than one year If longer storage time is required contact the factory for additional storage information INSTALLATION
37. dary level is indicated by after the name Access to the various levels can be controlled by a password Refer below 3 5 1 EXIT When the menu is displayed it defaults to the EXIT selection At this point pressing the MENU button will return to the graphic display 3 5 2 ALARM RESET Pressing the MENU button after selecting ALARM RESET will reset any alarm that is active and latched and then exit the Menu Mode When the alarm is not latched but is still in alarm selecting this option will briefly reset the alarm which will then activate again 3 5 3 RESET TOTAL To reset any channel programmed as Totalizer Refer to XXXX press the MENU button use the Up Arrow A or Down Arrow button to highlight RESET TOTAL and then press the MENU button again A sub menu will appear with choices to select CHAN A CHAN B and BOTH Use the Up Arrow A or Down Arrow button to highlight the Channel to reset or choose BOTH to reset both channels synchronously and press the MENU button Press the Left lt Arrow button to exit 3 5 4 RECORD MODE To begin or end recording in the data card press the MENU button use the Up Arrow A or Down Arrow button to highlight RECORD MODE and then press the MENU button again Several options appear in a sub window OFF ON and TRIGGERED To exit at this stage without changing the current setting press either the Left lt or Right gt Arrow button Otherwise use the Up Arrow 4 or
38. e There are a number of custom conversions available in the unit to take care of special inputs such as thermocouples and RTDs which need special scaling and linearization These are preset in the unit and require no modification There is also the capability to customize any input variable that has a linear relationship to the measured variable The relationship between the required variable and the input variable must satisfy the equation for a straight line y mx b where y is the output value to be displayed and recorded x is the input variable typically volts or milliamps DC m is the scale factor slope of the line which defines the relationship between the input and the displayed variable and is a constant linear relationship and the factor b known as the y intercept is a constant offset variable that may be positive or negative This facility to scale the input is found in the ADVANCED SETUP menu and is available to each channel independently Here the user can easily scale the input and set the displayed units using three alphanumeric characters The scaling is achieved in the unit in the CHANnel X SETUP option X A or B in the ADVanced SETUP menu First set the displayed LO SCALE which may be positive negative or zero Then set the displayed HI SCALE for the full scale input The unit will then automatically compute the scale factor and offset TABLE OF CONTENTS 14 Setting the engineering units is done in the sa
39. e left as a percentage and the equivalent record time at the current settings To remove the Card Status pop up window select CARD STATUS again 3 5 8 INFO To display the System Information press the MENU button use the Up Arrow A or Down Arrow button to highlight INFO and then press the MENU button again This will show the Firmware revision and build as well as the MAC Address of the Ethernet option if fitted on the TREND screen If the TREND screen is not displayed this menu option will have no effect Press the Up Arrow A to remove the information from the TREND screen or leave it to scroll off the trend screen at the chart speed rate 3 5 9 SAMPLE RATE To adjust the sample rate the rate at which data is recorded and displayed press the MENU button use the Up Arrow A or Down Arrow button to highlight SAMPLE RATE and then press the MENU button again The SAMPLE RATE menu option may be password protected When entering the SAMPLE RATE menu the rate highlighted is the current sampling rate To exit at this stage without changing the current setting press either the Left lt 4 or Right b button In this manner the user can check the current sampling rate at any time without affecting the recording To change the sampling rate use the Up Arrow A or Down Arrow button to highlight the desired sample rate and then press the MENU button The sample rates vary from a high of 100 S sec Samples per second to
40. ed to sample at a rate of 70 samples per hour a little over once per minute however if this is now printed on a laser printer it will fill less than 1 3 of an inch It is the amount and quality of the data that counts Another advantage of the paperless recorder is that it can sample internally at 100 samples per second one every 0 01 seconds These samples can be averaged or peaks or valleys can be detected and then this data can be stored at the chosen sample rate Trial and experience will yield the best sample speeds for the application Start with a faster sampling rate than you think you will need you can always slow it down in the future As a rule of thumb one sample every 10 seconds should give the equivalent information that 1 inch per hour of chart paper would 4 TABLE OF CONTENTS 1 2 REVIEWING DATA One of the biggest features of this recorder is its ability to show historic data and trends The data on the graphics screen can be rewound like a tape recorder scrolling back in time displaying past data on the screen while still recording data in real time The data can also be compressed on screen showing a whole day or week s worth of recording on one screen enabling trends or irregularities to be spotted easily A data cursor can be moved around the screen to uniquely identify samples in both time and amplitude Refer to Section 3 for the specifics on reviewing data 1 3 ZOOMING AND CONDITIONING DATA The recorder acquir
41. es data with greater resolution than can be displayed on the screen The user has the ability to ZOOM in to amplify the data either 2 or 4 times equivalent to using a magnifying glass on the display These ZOOM windows can be scrolled up or down to cover the entire data spectrum The vertical scale automatically adjusts to the zoom level and position to enable resolution of minor changes in input signal More information The recorder also acquires data at a rate faster than what may be displayed on the screen The user can set the sampling rate from 100 samples per second down to 1 sample every 10 minutes When sampling slower than 100 samples per second the recorder can be programmed to record the average maximum or minimum values Thus if a sample rate of 1 sample per minute is chosen the recorder will still sample internally at 100 samples per second while computing the average or detect and store either the maximum peak value or minimum valley value depending on the mode programmed It will then store this value when the minute is up Unless required otherwise it is recommended that the average value be used for recording since this will tend to filter or smooth the data See Advanced Setup Menu for details 1 4 CUSTOMIZING There are many operating features and parameters that the user can program All settings are stored in nonvolatile memory and are recalled each time the unit is powered on The display can be scaled to read in enginee
42. essure situation once our target pressure has been reached say 150 The lockout prevents the alarm activating at startup The alarm remains deactivated until the input exceeds the setpoint Now the alarm arms and any future time that the input drops below the setpoint the alarm will activate 15 TABLE OF CONTENTS 2 5 2 Setting Alarms Setting and configuration is done in the Advanced Setup Menu The alarm setpoints are set in the same units as the input type and may be different for each channel When setting the actual setpoint value the value may be incremented in steps other than what is expected unit steps This is due to the fact that the input is converted into a digital value with a finite resolution It is not possible to set a setpoint value that cannot be resolved by the internal microprocessor Select the closest value to the exact value you require it will always be with 0 5 The same applies when setting the deadband Note that when configuring the alarms there is no correlation between inputs alarms and relay outputs These are user defined Each alarm can be assigned to only one input channel When setting up each alarm channel the user should DISABLE the alarm so that parameters may be changed WITHOUT AFFECTING THE RELAYS This is done in the ALARMS menu by selecting the ENABLE option so that no Y appears to the left of this option Once everything is set select ENABLE once more to activate the alarm indicated by the
43. ey to escape without change Use MENU key to select and exit Enter Password using V A lt gt then press MENU Repeat at prompt press MENU to select and exit Enter Password if set then press MENU See Section 4 Adjust Viewing angle VIEW ak and Back Light BKLT AW Press MENU to exit TABLE OF CONTENTS 25 4 0 ADVANCED SETUP The ADVANCED SETUP menu may be password protected This menu is used to program the various operating parameters of the recorder This includes analog inputs alarms display settings the clock and various trigger modes All items on this menu have one or more sub menus To locate the Advanced Setup menu press the MENU button from any normal view mode The Advanced Setup menu will not be visible when the menu first appears Use the Up Arrow A and Down Arrow buttons to scroll and highlight ADV SETUP and press the MENU button This will bring up the Advanced Setup menu shown on the left Current settings in sub menus are indicated by a v check mark along side the item or by the item being highlighted See above for details on entering data 4 1 CHANNEL SETUP CHAN A SETUP CHAN B SETUP ALARMS RELAYS DISPLAY DATA CARD CLOCK BEEPER SAMPLE TRIG REC TRIG EXT INPUT ALT LANG UNIT TAG COMMS This menu option enables the user to program the inputs of the recorder Each channel can be set up as an analog input volts currents thermocouple or RTDs or as digi
44. he ability to be triggered by certain events that are generated internally or optionally externally which will enable it to automatically change sampling speed or begin or end a recording session The trigger can be any alarm or the external input The user can thus set the unit to record at a slow sample speed until some alarm condition is triggered and then change to a higher sample rate to record the transient Another example is the use of the external event trigger to start and stop recording allowing the selective recording of specific events The event triggering is setup in the Advanced Setup Menu option The control of recording stopping and starting is set in the REC TRIG Record Trigger menu option Section 4 9 while the changing of sample speed is controlled via the SAMPLE TRIGger menu option where a second set of sample speeds will be presented for the triggered speed change Section 4 8 This rate may be slower or faster than the regular rate depending on application The external event may be used in the same manner as the internal alarms for triggering a change of speed or record status The external event trigger characteristics are set in the ADV SETUP EXT INPUT menu option If the recorder is triggered but not recording the red LED will blink at a 1 second interval 3 7 STATUS LINE INDICATORS The bottom line of the graphics LCD display is used to indicate the status of the display and of the recorder itself These sta
45. hecked ALARM 1 Sample Rate change on Alarm 1 ALARM 2 Sample Rate change on Alarm 2 ALARM 3 Sample Rate change on Alarm 3 ALARM 4 Sample Rate change on Alarm 4 EXT INPUT Sample Rate change on External Input 4 9 RECORD TRIGGER This option allows the user to choose an event to start the recording Use the Up Arrow A or Down Arrow buttons to scroll and highlight REC TRIG and press the MENU button Select either OFF ALARM 1 through 4 or EXTERNAL INPUT as the record trigger Ka Note that if an alarm reset delay is set see Section 4 2 the unit will continue to record for this time period AFTER the alarm has gone away 4 10 EXTERNAL INPUT This option allows the user to program the external digital input This needs to be programmed before it can be used for event triggering if programmed above Use the Up Arrow A or Down Arrow buttons to scroll and highlight EXT INPUT and press the MENU button The menu options are shown below RESET DELAY Time in seconds from EXT input absent till recognized LATCHING Once set will remain set till the RESET option is pressed LOCK OUT External Input requires a change of state in order to be recognized For a High condition on startup or reset if the input is high at that time it needs to go low first then high in order to be recognized DEFAULT Set Defaults Disabled High level all else set to zero TABLE OF CONTENTS 31 4 11 ALT LANG The DC1250 supports English as
46. ic and recorder chart speed slower chart speeds will result in faster updates over the Ethernet Note that the browser shows the recorder status in real time Navigator Software The Navigator software enables the user to fully interact with the recorder over the Ethernet You can alter settings stop and start recording download data in real time for plotting or archiving on the PC and you can download historic data files Refer to the Navigator Software manual for additional information 5 3 CALIBRATION Before leaving the factory the recorder is calibrated using NIST traceable sources The calibration values are stored in non volatile memory The unit is calibrated to meet specification but the user may wish to re calibrate the unit or calibrate specific input ranges for increased accuracy Calibration is the process of fine tuning each input for various differences that may arise due to manufacturing processes gain errors temperature offsets and other physical parameters Real analog to digital A D converter values are corrected by first adding an offset correction value nominally zero to the reading to correct for offsets from zero and then multiplying it by a span correction value that s nominally 1 to correct for gain errors Calibration setup can be found in the Channel x Setup Menu x A or B under the ADVANCED SETUP menu options Each channel needs to be calibrated independently There are four options on the calib
47. ils AJW 0423009 REV1 6 MLK 070609 REV1 61 3 TABLE OF CONTENTS 1 0 INTRODUCTION This instrument is a versatile Solid State Data Recorder Panel Indicator It has all the capability of a traditional paper recorder variable chart speeds the ability to review historic data see trends and more with a number of specific exceptions NO PAPER to jam no ink to smudge and no pens to clog or break The data is stored in a Compact Flash memory card which can be easily transported Of course it does all the regular functions a lot better and the data can be transferred directly into reports spreadsheets or analysis programs Data can be examined and archived on any Windows XP compatible machine and can be printed out in various formats as required This instrument has two universal inputs so it can measure voltage current thermocouples and RTDs by simply selecting them from the menu It also has two potential free alarm output contacts and an isolated digital input The display can be user configured to graphics digital or a combination Maximum data storage is 2 Gigabytes Communication options include USB and Ethernet ports Things are done a little differently in a paperless recorder and there are a few new concepts that you may need to become familiar with There are more features and functions in this unit than you will probably use It is recommended that you read this manual in its entirety before attempting to use the instrumen
48. in part without the prior written consent of OMEGA ENGINEERING INC Where Do Find Everything Need for Process Measurement and Control OMEGA Of Course Shop online at www omega com TEMPERATURE 4 Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies 4 Wire Thermocouple RTD amp Thermistor lA Calibrators amp Ice Point References lA Recorders Controllers amp Process Monitors LY Infrared Pyrometers PRESSURE STRAIN AND FORCE LY Transducers amp Strain Gages LF Load Cells amp Pressure Gages 4 Displacement Transducers LF Instrumentation amp Accessories FLOW LEVEL 4 Rotameters Gas Mass Flowmeters amp Flow Computers A Air Velocity Indicators A Turbine Paddlewheel Systems A Totalizers amp Batch Controllers pH CONDUCTIVITY LF pH Electrodes Testers amp Accessories 4 Benchtop Laboratory Meters G Controllers Calibrators Simulators amp Pumps 4 Industrial pH amp Conductivity Equipment DATA ACQUISITION 4 Data Acquisition amp Engineering Software 4 Communications Based Acquisition Systems IL Plug in Cards for Apple IBM amp Compatibles IP Datalogging Systems lA Recorders Printers amp Plotters HEATERS 4 Heating Cable 4 Cartridge amp Strip Heaters 4 Immersion amp Band Heaters IP Flexible Heaters 4 Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL 4 Metering amp Control Instrumentation lA Refractometers IL Pumps a
49. ly charge 5 2 ETHERNET OPTION Setting the IP Address The recorder needs to have the IP address set manually by the user The address should be set so it is compatible with the environment into which it connects To set the IP address Select MENU Using the A Y buttons select ADV SETUP then COMMS Select IP ADDRESS then use the A V gt lt keys to set an address ka selects which group of digits to adjust then A W changes the number To accept the address press the MENU button The IP address you set depends on how you plan to access the device If you have a local area network connection the IP address needs to match the subnet setting on your computer The address will be in the form 192 168 0 210 Check your computer s IP Address then set the recorder address so that the first three sets of numbers match that of your computer The last digit should be different and should be unique check with your IT department if you are unsure Select SUBNET MASK and set it to 255 255 255 0 which is typical or to whatever your system requires and then press the MENU key Use the lt key to exit the menu If you plan to access the recorder from outside your local area network then you need to set the Default Gateway IP address Again you can get this information from your own PC settings The Default Gateway is used by the recorder when an IP packet s destination address belongs to someplace outside the local subnet thus requiring mo
50. me menu location using the CHAN UNITS option to set the three alphanumeric characters Let us assume we have an input from a pressure transducer of 1 to 5 volts DC corresponding to real world units of zero to 250 PSI Pounds per Square Inch of pressure Assume we choose the 0 to 5 volt input The actual output span of the transducer is 4 volts with 1 volt 0 PSI and 5 volts 250 PSI This is equivalent to 62 5 PSI per volt The LO SCALE foi i which is the 0 volt value is equivalent to 62 5 PSI 0 125 and should be set to this value and the HI SCALE is PSI set to 250 The engineering units are set to PSI OFFSET The display will now show zero to 250 PSI for 1 to 5 Volts input The linear scaling is shown in Figure 2 5 Figure 2 5 2 5 ALARMS The Recorder has four programmable internal alarms with dual relay output The alarms can be associated with either analog input channel can be set as high or low latching or non latching with or without lockout capability Each relay has a set of potential free normally open contacts Form A SPNO that are accessible from the rear panel via screw terminal connections Alternatively the relays can be set to the failsafe mode normally closed Form B SPNC The relays can be assigned to any all or none of the alarms Refer to section on Alarms and Relays in Advanced Setup Menu 2 5 1 Alarm Types A high alarm is active when the input is greater than the setpoint A low alarm is
51. minals 13 TABLE OF CONTENTS 2 3 5 USB Port Option The USB Port is an option and will be installed only if specifically ordered It is a serial connection to a PC that allows the user to program the recorder remotely start or stop recording and download real time data 2 3 6 ETHERNET Port Option The Ethernet Port is an option and will be installed only if specifically ordered It allows the user to program the recorder remotely start or stop recording and download real time data The IP address is set in the Advanced SETUP Menu Refer to Section 5 2 for detailed instructions on the Ethernet interface option 2 3 7 Isolated DC input Option The unit may be powered by an external DC source with the isolated DC to DC option Connect the unit to the external DC source and observe the voltage and polarity of the inputs In order to fully comply with the CE EMC Directive 89 336 EEC the power cable should be looped through the ferrite bead provided close to the terminals 2 3 8 Cleaning The unit may be cleaned by wiping with a soft cloth The front panel and display keypad may be wiped with a slightly damp soft cloth containing soapy solution or a mild detergent Do not use any lemon based citric acid product to clean the display keypad NOTE THE UNIT IS NOT WATERTIGHT 2 4 INPUT SCALING The input to the recorder is often a standard process variable e g voltage rather than the actual units being measured e g pressur
52. mp Tubing lA Air Soil amp Water Monitors lA Industrial Water amp Wastewater Treatment A pH Conductivity amp Dissolved Oxygen Instruments M 4350 0709
53. mpressed values The display can function normally in compressed mode may be paused or the user can scroll back and forth using the left lt and right gt arrow buttons e The H indicates the display is in the HOLD condition While in HOLD the trends do not update The display enters the HOLD condition when the ID Cursor K is present or the user scrolls in the horizontal direction using the left lt and right gt arrow buttons Exit the HOLD mode by pressing the MENU button 6 DO NOT INSERT OR REMOVE THE COMPACT FLASH CARD 7 TABLE OF CONTENTS WHILE THE BUSY LED IS ON 1 7 OTHER GRAPHIC MODES In addition to the full screen trend mode shown section 1 6 there are two additional graphic display modes The Dual Digital mode as shown below enables both channels to be shown as Digital values similar to a digital panel meter The user has the option of showing the displays in normal or reverse video shown modes and the display can be set to blink on Alarm Condition E DUT Poi PUMP The other Graphic mode is a split screen with the trend in the top half and the digital display in the lower half as shown below When selecting this mode Channel B is the default digital value but can be switched in the Advanced Setup menu TABLE OF CONTENTS 2 0 2 1 2 2 INSTALLATION AND SETUP UNPACKING 2 1 1 Initial Inspection Exercise care when unpacking the instrument from the shipping carton The instrument is pa
54. n the card are in DOS standard format and can be managed on any Windows based machine with a CompactFlash reader internal or external The content of the files is in proprietary binary format and requires special software to read the data All units are supplied with the Navigator Lite Software which allows the data to be exported to Excel This space intentionally left blank 17 TABLE OF CONTENTS 3 0 BASIC OPERATING INSTRUCTIONS The Basic mode of operation encompasses those functions that would be done on a routine basis and relate primarily to viewing and reviewing data with some use of the menu system The advanced mode while technically still simple to operate involves setting up the unit and would typically need to be done only once 3 1 BASIC MODE OF OPERATION Basic operations are all done using the five buttons on the front panel shown below and the first level menu 4 EKPAND MENU a y 2nd FUNCTION ZOOM ZOOM gt COMPRESS Each arrow button has dual functions The second function is activated by pressing and holding the MENU 2nd Function button and then pressing any of the other buttons The 2nd function of each button is denoted by the text under the arrow symbol EXPAND COMPRESS ZOOM and ZOOM The unit need not be recording to the memory card in order to manipulate data The data available however is dependent on how long the unit has been operati
55. ng the sample rate and the buffer or memory card size 3 2 VIEWING HISTORIC DATA Any data that is not currently visible on the screen is historic data To view past data the left a and right gt arrow buttons are used to rewind al or fast forward b the data scrolling When rewinding data will be retrieved from the memory card or from the internal buffer and is available as far back as the start of recording When fast forwarding data is available up to real time The time and date stamp on the screen indicates the relative time of the samples being viewed Depending on the amount of data to process there may be delays before the screen reacts Historic viewing by scrolling is limited to the file or files created since recording was manually started via the RECORD MODE Menu ON If NOT recording scrolling back in time is limited to the content of the internal buffer The history buffered is dependent upon the sampling speed Data is presented as latest data first It is possible to view data from other files of previously recorded data or even data recorded on another machine using the View File menu At any stage during the rewind or fast forward process the screen can be restored to currentor real time display by pressing the MENU button Ka When the data on screen is not current an D appears on the status line to indicate that the rewind or compress mode is active and the data is on Hold 3 3 COMPRESSING AND EXPANDIN
56. nth than there would be in a year There will be less error in a week than in a month and so on When you reset the Totalizers the errors are reset as well FOR EXAMPLE To totalize a rate such as a 4 20 mA input set the channel as usual to the engineering units then go to the filter section and choose your rate from the list of selections from secx1k to dayx100 as described above To use the COUNTER FUNCTION go to MENU gt ADVANCED SETUP gt CH Aor B SETUP gt INPUT TYPE gt COUNTER From this pane select your reset and gating options as well as your full scale range The counter function can be used to totalize pulses accurately from flow meters This can provide more accurate totals than using the totalizer function on a sensor that provides a rate APPENDIX F ALTERNATE LANGUAGES The Following procedures are used to enter and activate a second language If necessary insert a CF card into the card drive slot Menu into the ALT LANG submenu found near the bottom of the ADV SETUP To obtain a copy of the language file for use as an initial template for another language or to make changes to a pre existing alternate language select SAVE LANG You will then be prompted to select a file name Use the standard editing or directory selection methods to name the file Wait for the transient message DONE to appear Use Note pad or other simple text editor to present the file for editing The full name of the language file is
57. o flash memory and can be updated in the field It is loaded from the compact flash card User s can upgrade their firmware by simply downloading the latest firmware from the Company website saving it onto the CompactFlash card inserting the CompactFlash card into the unit and following the steps below Before updating firmware save existing configurations and language files see below The upgrade file is named DC125XXX hex where XXX reflects the firmware revision number Once this file is on the CompactFlash card insert the card into the unit and turn the power off Press and hold the MENU button and Left Arrow lt simultaneously and power the unit back on The POWER LED will come on fully bright the other will blink as the card is accessed If the program is loaded successfully the two LEDs will alternate If the load failed the two LEDs will blink in unison It takes 10 to 15 seconds to load the program If the load should fail try it again If it still fails reload the file on the card Remove the power and re apply it The screen will show the latest firmware revision and build date Recommended handling of alternate languages during a firmware update procedure H If no backup file of the alternate language file exists then use SAVE LANG function to save it now before the firmware update is performed H Perform the FIRMWARE update described above H Use the LOAD LANG function to re install the alternate language
58. o various features of the unit and are described below Not shown are the MENUS which pop up over the display The menus are in the form of those shown in Sections 4 and 5 The numbers in parenthesis below refer to the section that covers the topic in detail A CompactFlash card slot Manually insert the card into the unit to store data and configuration information This card can also be used as a means of updating the firmware in the unit Cards up to 2 Gigabytes in size can be used Busy LED Red Is on when the unit is recording and blinks rapidly whenever the unit is accessing the CompactFlash card The LED blinks at 1 second rate if the unit is triggered but not recording Do not attempt to remove the card when this light is on Power LED Green Je on during normal operation If the optional internal battery pack is present this LED will blink during power failure to indicate the unit is running off internal batteries Optional USB interface enables connection to a Windows XP compatible PC Navigation buttons are used to set up and navigate around the display The buttons are all dual function the second function is initiated by holding down the MENU button while pressing one of the other buttons The second function is printed on each button Date and Time shows the actual time of day real time The time is displayed user 6 TABLE OF CONTENTS selectable in 12 or 24 hour format The user can also select E
59. presence of the v Refer to Section on Setting Alarms LS When setting up alarms you may get unexpected results from the relays if they are enabled Ensure there is nothing connected to the relays that could result in an accident due to random closing of the relays during setup and always DISABLE the alarm as described above Make the changes and then re enable the alarm There are many different ways the alarms can be set up All the alarms can be assigned to a single channel and may be of the same type giving for example a various degrees of high warning and ultimately a high shutdown indication Also the relays may be assigned to any combination of alarms This would allow a single relay output to indicate any alarm active The combinations are endless 2 5 3 Alarm Indication There are three indications of alarm condition the relay outputs visual icons on the display and audible alarm When an alarm is armed and functioning it is indicated by a small 1 2 3 or 4 in reverse video on the bottom left hand side of the graphic display These status indicators remain on as long as the alarm is enabled If an alarm is triggered in alarm condition the status indicator will blink and the internal beeper will sound The beeper can be permanently disabled from the Advanced Setup Menu BEEPER ALARMS OFF The relays close on an alarm condition assuming they have been set up correctly The relays can be set as fail safe by rever
60. ration menu CAL ZERO adjusts the offset correction above or below actual 0 zero in steps equal to the resolution of the A D converter itself SPAN adjust a span correction value above or below actual 1 also in small amounts CAL NOM Calibrate Nominal depending on the input range selected either resets the correction values to 0 and 1 or copies those values from the TABLE OF CONTENTS 34 range it s a derived from This usually affects only the input type category selected for the current channel CAL ALL Calibrate Nominal All will reset all correction values for all input types on both channels when selected from any input type and channel a sort of master reset This is the default in the event that calibration data is found to be corrupted in the non volatile memory 5 3 1 Basic Calibration All calibration values are derived from a couple of key calibration points Thereafter any fine tuning done to a specific input on a channel is saved for that channel and input range only The key calibration constants are for Lo Volts covering the 250mV 1 25V 2 50V ranges and should be done on the 250mV range each channel Hi Volts covering the 5 00V 12 5V 25 0V ranges and should be done on the 5 00V range each channel THERMOCOUPLES which are derived from the Lo Volts calibration value require an additional offset to compensate for the ambient temperature sensor each channel RTDs which are derived from Lo Volts
61. re than one hop of Ethernet communication The Default Gateway address is usually an interface belonging to the LAN s border router Connect the Ethernet cable to the recorder There are two LEDs on the connector one indicates connection the other indicates activity To connect the recorder directly to your computer you need to use a crossover cable You can connect using a hub or a switch using a patch cable TABLE OF CONTENTS 33 The connection can be tested by using the DOS Command Box and pinging the units At the DOS prompt type Ping 192 168 0 210 use the IP address you set If the connection is good you will see a series of replies from the recorder If you cannot connect try pinging the address with the recorder disconnected from the Ethernet If you get a reply there is another device with that IP address Change the IP address on the recorder There are two methods of connecting to the recorder over the Ethernet Browser connection and Navigator Software Browser connection Launch your browser Internet Explorer preferred V6 or later You need to ENABLE ACTIVE X and JAVASCRIPT From the browser toolbar select TOOLS then INTERNET OPTIONS then SECURITY Select CUSTOM LEVEL and choose MEDIUM LOW or adjust the settings manually Enter the Recorder IP address into your browser and click GO You should see a picture of the Recorder and the data should update at a 3 to 5 second update rate depending on Ethernet traff
62. ring units and the trace can be labeled accordingly with up to three alphanumeric characters Four alarms are fully user programmable and can be associated with either channel or the external input The Alarm levels can be set in the engineering units of the display the sense of the alarm the type and the deadband or hysteresis can be individually set for each alarm Optional relay outputs can be assigned independently to each alarm A reset delay feature is also available There are other features which may be programmed by the user including the time stamping mode either real time or elapsed time clock update rates file names beeper operation etc Refer to Advanced Setup 1 5 TRIGGERING The recorder has the ability to change sampling speeds and stop or start recording as a result of a triggered event This event may be tied to any of the four internal alarms or optionally to an external signal This enables the unit to monitor a process without recording or to record at a slow speed to conserve card space When an external event or internal alarm condition occurs the unit will begin recording or change to a higher sample rate for the data of interest More Information 5 TABLE OF CONTENTS 1 6 THE GRAPHICS LCD DISPLAY J M H 5 G F E D A Be Recorder Front View showing TREND Display The above diagram is a representation of the recorder in the TREND mode The alpha characters around the border point t
63. rjudicial para y el ambiente NO se DESHAGA de este producto el desecho municipal como no clasificado Estas necesidades del producto para SER RECICLADAS de acuerdo con las regulaciones locales contactan su administraci n local para m s informaci n Este producto puede ser retornable a su distribuidor para reciclar contacta el distribuidor para detalles Afin de respecter la directive europ enne 2002 96 EC sur l Equipement Electronique et les D chets Electriques Ce produit pourrait contenir des mati res qui peuvent tre dangereuses pour la sant de l homme et de l environnement Ne pas jetter ce produit dans un container municipal inappropri Ce produit doit tre recycl en accord avec les arr t s locaux contacter les autorit s locales pour plus de renseignements Ce produit peut tre renvoy au distributeur pour recyclage Contacter votre distributeur pour plus de details Um den Vorschriften der EU Direktive 2002 96 EC bezueglich elektrischer und elektronischer Abfallstoffe nachzukommen Dieses Produkt kann Materialien enthalten welche gesundheitsgefaehrdend und umweltschadlich sind Dieses Produkt DARF NICHT wie unsortierter Hausmuell entsorgt werden Dieses Produkt muss gemaess den oertlichen Bestimmungen recycled werden bitte kontaktieren Sie die lokalen Behoerden fuer weitere Informationen Sie koennen dieses Produkt zum Recycling an Ihren Haendler zurueckgeben bitte kontaktieren Sie den Haendler fuer weitere Deta
64. roblem you can ZOOM in on a portion of the graph and get increased resolution ZOOM applies to each channel independently The trace that will zoom is the one whose scale is shown to the right To adjust the other trace simply wait for its scale to appear To ZOOM in and amplify the graph press and hold the MENU key press the ZOOM A button and then release both buttons The display will zoom in by 2 Note that the scale units change to reflect the increased zoom level There are three zoom levels available x1 x2 and x4 To decrease the zoom level or zoom out press and hold the MENU key press the ZOOM button and then release both buttons While adjusting the zoom scale flipping is suspended Turning the other trace off will also suspend flipping Note that when zoomed in at any zoom level the A and e buttons will move the graph relative to the window enabling viewing of any part of the graph within the zoom window When zooming the trace expands or contracts about the centerline If zooming drives the trace off the screen it will automatically reposition itself at the top or bottom vertical edge of the chart Once in a zoom level all functions are operational on the zoomed display Ka When in a zoom mode the zoom level is indicated in the lower half of the scale for the associated channel X2 X4 etc No indication indicates normal scale X1 To exit the zoom mode zoom out MENU Y as far as possible until the
65. rvice Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have FOR NON WARRANTY REPAIRS consult the following information available BEFORE OMEGA for current repair charges Have the contacting OMEGA following information available BEFORE 1 Purchase Order number under which contacting OMEGA the product was PURCHASED 1 Purchase Order number to cover the 2 Model and serial number of the product COST of the repair under warranty and 2 Model and serial number of the 3 Repair instructions and or specific product and problems relative to the product 3 Repair instructions and or specific problems relative to the product OMEGA Ss policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2004 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or
66. s no OFFSET adjustment for these inputs Thermocouple and RTD linearization tables are very accurate usually calibrating the 250mV range for the same channel and then copying the calibration values using NOMINAL should be enough Remaining sources of error are the ambient sensor probably small for the thermocouple and the current source small for the RTD and the actual sensors themselves The ambient sensor can be calibrated by adjusting the OFFSET with the thermocouple at some known temperature such as ice water or a known room temperature with a wire short on the input The input sensor span adjustment would need a high temperature point to calibrate There can be interaction between the OFFSET and SPAN with the thermocouple input since it can t be easily determined when exactly 0 volts is applied in combination from TABLE OF CONTENTS 36 the ambient and input sensors This can happen with other input types where the input used for the OFFSET adjustment does not present 0 volts to the input Calibration values are copied to an EEPROM non volatile device when performing the calibration operations These values are copied from the EEPROM upon every power up of the recorder and tested for corruption If the values are found in error then nominal values are inserted in all categories 5 4 SPECIFICATIONS Input Power Battery Option Output No of Channels Universal DC Input DC Input Voltage Current Thermoco
67. sing the logic of the alarms Advanced Setup Menu RELAYS FAILSAFE TABLE OF CONTENTS 16 2 6 MEMORY CARDS The memory cards used are standard CompactFlash cards We recommend the use of Sandisk CompactFlash cards The cards are keyed and can only go into the recorder right side up The largest capacity card that can be accommodated is 2 Gigabytes 2 6 1 Care of the Data Cards Do not expose the cards to direct sunlight or extremes of temperature for any length of time Do not expose to moisture Do not bend or twist Avoid high static discharge When mailing card use a suitable package to avoid postal damage When transporting use an anti static bag or the plastic enclosure in which the card is supplied 2 6 2 Card Storage Capacity and Data Type Depending on what else is stored on the card e g configurations files other data files data storage capacity can be roughly calculated by the following formulas Number of samples is card size divided by 4 4 The time that it will take to fill a card is roughly the number of samples divided by the sample rate For example a 32MB card will hold roughly 32 000 000 divided by 4 4 7 272 727 samples At 5 samples per second this is 1 454 545 seconds or 404 hours or approximately 16 8 days If you show the Card Status window MENU CARD STATUS it will indicate how much time is left on the card It also displays the current Filename that is being used for recording The files o
68. t The balance of this introduction will attempt to introduce some of the more unique features of this paperless recorder 1 1 CHART SPEED TO SAMPLE SPEED A major difference between paper and paperless is SAMPLE SPEED which is analogous to CHART SPEED in the paper recorder There is an apparent chart speed the rate at which the samples appear to move across the Graphics Display but unlike paper recorders the display is made up of discrete data points each of which is a distinct sample of the data being measured The rate of movement across the screen is thus a direct function of the sample rate The major factor in deciding what sample rate to select is to know how much data is enough In a paper recorder a chart speed of 1 inch per hour is fine for a process that does not vary very quickly but would result in a thick blur if trying to record a 1Hz sine wave Unlike a paper recorder every point recorded by the paperless recorder is uniquely identifiable no matter how dense it appears on the screen It is always better to have too much data than to have too little The only consideration is the amount of space used in the memory card To relate chart speed to sample rate we need to consider how we plan to reproduce the data The graphic LCD display has a density of 70 pixels data points per inch a typical dot matrix printer has 180 pixels per inch and a laser printer 300 pixels per inch Thus to fill one inch of the display in one hour we ne
69. tal inputs from RPM or frequency measurements There is no need to swap out modules since the inputs are universal Filtering may be applied to each channel for stability of readings or to catch peak values if the display rate is slower than the sample rate The unit always samples at 100 samples per second per channel For increased accuracy each range may be calibrated independently Use the Up Arrow A and Down Arrow buttons to scroll and highlight CHAN n SETUP n A or B and press the MENU button The menu options are shown expanded below INPUT TYPE Note Menu will differ depending on Input Type selection Turns Channel OFF toggles Y OFF 26 TABLE OF CONTENTS LOW SCALE Default value is low end of range For Offset Use V AP keys to adjust lt key escapes MENU key to Save and Exit HIGH SCALE Default Value is top end of range For Full Scale Use V AP keys to adjust lt key escapes MENU key to Save and Exit CHAN TAG Enter a Channel Tag Identifier up to 5 Characters Use V A 4P keys Use MENU key to Save and Exit CHAN UNITS Default value is Range value Enter a Channel Units Some Ranges have defaults up to 3 Characters Use V A ak keys Use MENU key to Save and Exit FILTER Note Unit always samples at 100 samples sec internally NORMAL No filtering AVERAGE Display shows AVERAGE over last sample interval HI PEAK Display shows HI PEAK max values over last sample interval LO PEAK Display shows
70. the slowest 10 min S minutes per sample sec S is seconds per sample To return to the graphic screen press either the Left lt or Right gt button 3 5 10 PASSWORD PROTECTION To set reset or change a password press the MENU button use the Up Arrow A or Down Arrow button to highlight PASSWORD and then press the MENU button Ka This menu option may be password protected Follow the prompts Enter a 4 digit password using a combination of DP YA buttons The key presses are echoed in a pop up window and roll around first in first out Once you have entered your password press the MENU button If you are entering a new password you will be asked to repeat your password and then press the MENU button At this point the password is entered and the unit is protected To clear the password enter the current password and then simply press the MENU TABLE OF CONTENTS 22 button when prompted to enter the new password A null password is no password at all 3 5 11 ADV SETUP ADVANCED SETUP See Section 4 3 5 12 DISPLAY ADJ ADJUST To adjust the backlight brightness and viewing angle press the MENU button use the Up Arrow A or Down Arrow button to highlight DISPLAY ADJ and then press the MENU button again Adjust the Viewing Angle using the lt and gt keys and the Backlight Intensity using the A and Y keys Press the MENU button to accept the changes and exit 3 6 EVENT TRIGGERING The recorder has t
71. tus icons consist of reverse video characters or letters that appear according to operations performed and are intended to prevent data on the display from being misinterpreted and to indicate the status of the alarms 1234X gt lt HF From left to right these icons are as follows EE These icon symbols indicate that the alarms are enabled 1 is Alarm 1 etc Any number of them may be present depending on how the alarms have been set up If an alarm is enabled a solid block will be present If the alarm has exceeded the setpoint i e is in an alarm condition its symbol will be blinking i This symbol indicates that the external input is enabled If the external input is triggered this symbol will blink E This symbol indicates the display is in the COMPRESSED mode The amount of TABLE OF CONTENTS 23 compression can be determined from the time date stamps on the display To exit from the Compressed Mode simply press the MENU button DI This symbol indicates the display is in the HOLD mode The displayed data is no longer real time and will not be updated The Hold mode is entered by pressing either the LEFT or RIGHT arrow button entering the compressed mode or viewing any internally buffered data D This symbol indicates the data on the display is from a FILE on the MEMORY CARD and not current data To view data from a file use the MENU selection option VIEW FILE Note that if currently recording viewing a file does
72. uple RTD Frequency Input Hz Speed Input RPM Input Impedance Measurement Rate Math Function Recorder 9Vdc 0 5V 5VA depends on external loads External AC Universal adaptor 100 240Vac 50 60 Hz Optional isolated 12 24 Vdc input not compatible with Battery Backup Option Internal battery pack provides uninterrupted operation during black out 6Vdc 2400 mAH NiMH Backup Time Depends on external load Without Ethernet 6 hours typical With Ethernet 2 5 hours typical 2 outputs 5Vdc 50mA to power external sensors Isolation 300V DC AC to system ground chassis 2 Isolated input 300V AC DC to system ground chassis Inputs share a common ground connection Resolution 0 025 Ranges 0 to 250mV 1 25V 2 5V 5V 2 5V 25V Accuracy 0 1 Accuracy 0 1 excluding 250 ohm external shunt required Ranges 0 20mA 4 20mA 0 50mA 10 50mA Accuracy 0 3 Ambient temp sensor accuracy 1 5 100 to 760 C 2 C 100 to 1000 C 2 C 100 to 400 C 2 C 80 to 400 C 2 C 148 to 1400 F 3 F 148 to 1830 F 3 F 148 to 750 F 3 F F 112 to 750 F 3 marc 2 or 3 wire Resolution 0 1 C Accuracy 0 3 Internal current source 1mA 100 ohm Pt385 100 to 750 C 148 to 1380 F 100 ohm Pt 392 100 to 750 C 148 to 1380 F Range 0 10 000 Hz or 0 600 000 RPM Accuracy Freq 1Hz RPM 1 RPM to 9 999 RPM then 10RPM Input
73. uropean or American formats and auto daylight savings adjustment See Clock setup Zoom Scale Indicator shows the zoom scale for the channel indicated if gt x1 Separate scale for each channel See zooming The right hand edge of the graphics area in which the traces are displayed This is the vertical scale area designated by the scale values at the top center and bottom of the scale The most recent data that is displayed in digital form at the top of the display J is against the right edge of this scale and moves left with time the most recent data is to the right and the oldest data is to the extreme left New data appears against this margin and the oldest data disappears off the screen at the extreme left The graphic cursor K will start against this right edge Vertical Scale Identifier this display alternates between Channel A and Channel B It displays the Channel Tag and the Engineering units See Channel setup Digital Window the top of the screen displays the values for each Channel including the Channel identifier the current value and the engineering units Channel A is displayed on the left and Channel B on the right This window displays the absolute digital value of the instantaneous last reading for the channel and is the right most sample value on the trend display G unless the cursor is active In that case it shows the value at the point the cursor intersects the trend line Cursor is displayed
74. w This space intentionally left blank TABLE OF CONTENTS 32 5 0 MISCELLANEOUS 5 1 BATTERY BACKUP OPTION If the recorder contains the Battery Backup Option there is a toggle switch on the back panel below the terminal block The switch is marked ON and OFF In the OFF position the battery is disconnected from the load and the recorder is off The battery charges with the switch OFF when the recorder is plugged into AC power In the ON position with external power applied the unit runs normally and automatically switches to battery backup in the event of a power failure The recorder continues to run from the battery until power is restored If the battery voltage reaches a preset low voltage threshold the battery is automatically disconnected and the recorder shuts off When external power is restored the unit starts up normally and the batteries begin to recharge Likewise the unit can run off internal battery without external power by simply turning the unit ON The recorder switch should be turned OFF when not in use Additionally there is a procedure to turn the backlight off when the unit is running on battery See Section 4 4 This action extends the battery life and the unit continues to operate normally The green power LED on the front panel will blink when the recorder is being powered from the battery Run times vary from 8 to more than 12 hours depending on load conditions It takes 10 to 14 hours for the battery to ful
75. when activated in the cursor ID mode This cursor can be moved using the left lt and right gt arrow buttons The values in the digital window J are the values at the point the cursor intersect the trend line Date Time Axis Delimiter the dotted vertical lines placed at equal increments along the Horizontal axes Time The Date Time stamp beside the line indicates the exact position of the line Both date and time may be shut off or relocated vertically These lines move with the trace at a speed dependent on the sampling speed This is configurable in Display Setup Channel B Trace the trend line is the graphic representation of Time horizontal versus Amplitude vertical and is shown solid to distinguish it from the Channel A trace which is shown as a dotted trend line This is configurable in Display Setup Graphic TREND Window shows the channel traces which may be compressed expanded zoomed scrolled and halted Status Icons these icons appear at various times to indicate the status of the unit and the display From left to right they are D The numbers 1 2 3 and 4 are the ALARM indicators one for each alarm The numbers are present when the alarm is enabled and will blink if the alarm is in an alarm condition e The X indicates the status of the EXTERNAL INPUT and is present when the external input is present e The icon indicates the display is compressed The horizontal time stamps indicate the current co
76. y that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Se