1. FCC Certifications C This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Mark Warning C This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protection requirement of Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility Company has an on going policy of upgrading its products and it may be possible that information in this document is not up to date Please check with your local distributors for the latest informa
2. UTP STP ____ RJ 45 100BA SE TX Category 5 UTP STP Cable Connections RJ 45 1000BA SE T Category 5 5e or enhanced UTP STP Fiber depend on Mini GBIC types Transmission 10 100M bps Full duplex Half duplex Standard ee Mode 1000MbpsFull duplex iSystem nee Power LED indications 6410 100M Link ACT 16 1000M Link ACT i8K MAC entries memory 340K bytes Buffer M emory Emission FCC CE VCCI Operating 0 400C 320 1040F Temperature i O perating f l Humidity 19 Anorconesnsing Power Supply ilnternal power supply 100 240V 50 60 Hz universal input 61NB G4170 200 C
3. e switch from slipping The recommend position has been square marked 2 Install the switch on a level surface that can support the weight of the unit and the relevant components 3 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation Rack mounting facilitate to an orderly installation when series of networking devices being installed The switch is supplied with rack mounting brackets and screws for rack mounting the unit Procedures to Rack Mount the Switch in the rack 1 Disconnect all the cables from the switch before continuing 2 Place the unit the right way up on a hard flat surface with the front facing you Locate a mounting bracket over the mounting holes on one side of the unit Insert the screws and fully tighten with a suitable screwdriver Repeat the two previous steps for the other side of the unit Insert the unit into the rack and secure with suitable screws optional Reconnect all the cables SNOW BW Network Cables Installation 1 Crossover or straight through cable All the ports on the switch support Auto M DI MDI X functionality Both straight through or crossover cables can be used to connect the switch with PCs as well as other devices like switches hubs or router 2 Category 3 4 5 or 5e UTP STP cable To make a valid connection and obtain the optimal performance Appropriate cables corresponding to different trans
4. mitting receiving speed is required To choose a suitable cable please refer to the following table Media Speed Wiring 10 100 1000M bps copper 10M bps Category 3 4 5 Utp STP 100M bps Category 5UTP STP 1000M bps Category 5 5e UTP STP 1000M bps Fiber 1000M bps The cable type differs from the mini GBIC Mini GBIC required you choose Please refer to the instruction came with your mini GBIC Port O peration The auto negotiation feature allows ports running at one of the following operation modes 10 100 1000M bps copper 10M bps Full Duplex Half Duplex 100M bps Full Duplex Half Duplex 1000M bps Full Duplex 1000M bps Fiber 1000M bps Full Duplex mini GBIC required Note For the last port when both the fiber and cooper interfaces are connected the system adapts the fiber interface and disables the relevant cooper port automatically Product Specifications IEEE802 3 10BA SE T IEEE802 3u 100BA SE TX IEEE802 3x full duplex flow control IEEE802 3z ab 1000BA SE T a epte a e e e e e e e e e e e e e e e e e e e e e e ae e e a e me e e m e me me me me e me e m me e me e m me e me e me m e m e m e m me e m e m m e me me e m m me me m e e me e m me e m e me ee e me e me e me m e me m m me e ee e me me me me e e ee m me m e e me e me me m i 16 10 100 1000 M bps auto MDI MDI X RJ 45 switching ports 1 Mini GBIC module sockets ee eh a RJ 45 10BA SE T Category 3 4 5
5. tion No part of this document can be copied or reproduced in any form without written consent from the company Trademarks All trade names and trademarks are the properties of their respective companies Copyright 2006 All Rights Reserved Unpacking Information Thank you for purchasing this product Before installation please verify that your package contains the following items 1 One 16 Port Gigabit Switch with SFP 2 One AC power cord 3 Rack mount brackets 4 User s M anual Introduction General Description Easily boost your networking throughput the product equips 16 Gigabit ports that lead you to a real Gigabit connection Users are now able to transfer large and high bandwidth needed files faster and hence get a real efficiency improvement In addition to the cooper ports one of the ports supports fiber connection with the equipped Mini GBIC ports for obtaining long distance communication This product offers users with fast and reliable network The store and forward architecture filters errors and forwards packets in a non blocking environment Flow control ensures the correctness of data transmitting The 802 3x and backpressure flow control mechanisms work respectively for full and half duplex modes The switch features with easy installation and maintenance It supports Nway auto negotiation protocol that detects the networking speed 10 100 1000 Mbps and the duplex modes Full Half automatically Au
6. to MDI MDI X function alleviates the effort to use crossover cables Also rich diagnostic LEDs are provided for users to get real time information of the connection status Key Features Complies with IEEE802 3 IEEE 802 3u IEEE 802 3ab and IEEE 802 3z standards 16 10 100 1000 M bps RJ 45 N way ports 1 Mini GBIC port for optional fiber optical communication Supports NWay protocol for speed 10 100 1000M bps and duplex mode Half Full auto detection Supports MDI MDI X auto crossover Supports full and half duplex operation on all copper ports Supports back pressure half duplex and flow control IEEE 802 3x Wire speed packet filtering and forwarding rate Store and forward architecture filters fragment amp CRC error packets Supports 9K bytes Jumbo frame Supports 8K bytes MAC address entries in whole system 1 340K bytes buffer Memory 6 Internal power adapter FCC VCCI CE Class A Meet ROHS The Front Panel The front panel consists of LED indicators For detailed LED definition please refer to the next paragraph LEDs Ddinition System LED Status Operation Steady Green The switch is powered on Off The switch is powered off Port LEDs LED Status O peration Steady Green Valid port connection at 1000 M bps E Valid port connection and there is data Blinking Green ue ay transmitting receiving Off Port disconnected or the port is connected at 10 Mbps or 100 Mbps 10 100M
7. transmitting receiving at 1000 M bps Attention The Mini GBIC slot shares the same LED indicators with Gigabit RJ 45 copper ports The Rear Panel 8 7 6 5 A 3 2 1 15 14 13 12 11 10 9 prc eeeeenee AC LINE 100 240 VAC 50 60Hz Power Receptacle To be compatible with the electric service standards around the world the switch is designed to afford the power supply in the range from 100 to 240VAC 50 60Hz Please make sure that your outlet standard to be within this range TO power on the switch plug the female end of the power cord firmly into the receptacle of the switch and the other end into an electric service outlet After the power cord installation please check if the power LED is illuminated for anormal power status Installation This switch can be placed on your desktop directly or mounted in a rack The installation IS a snap Users can use all the features of the switch with simply attaching the cables and turning the power on Before installing the switch we strongly recommend 1 Theswitch is placed with appropriate ventilation environment A minimum 25mm Space around the unit is recommended 2 Theswitch and the relevant components are away from sources of electrical noise such as radios transmitters and broadband amplifiers 3 The switch is away from environments beyond recommend moisture Desktop Installation 1 Attach the provided robber feet to the bottom of the switch to keep th