Home
GFK-2964, RSTi-EP Slice Profibus Network Adapter
Contents
1. GS NIVEN WPaty amp lar ia 74 V OC IN kjai ngi es TEH GMO N n LEHON i daa 24 v OC OUT at 24 V OC OUT Door for Micro iy ri out USB Port prz nja F GWD OUT o Vv EPXPBS001 Connection Block Diagrams va Internal from the control card 24V 10A Input 24 W10 A Output I EPXPBSO01 For public disclosure 6 RSTi EP Slice I O Profibus Network Adapter GFK 2964 Addressing The network adapter on the PROFIBUS DP is addressed via the two rotary switches Note A maximum of 125 addresses 1 to 125 can be assigned Each address may be assigned only once in the overall bus structure Addresses 1 and 2 are generally used by the control systems Bus addresses 000 plus 126 and higher may not be used The most significant digit is set with rotary switch H the least significant digit with rotary switch L The switches are labelled in the hexadecimal numbering system 0 to 9 A 10 B 11 C 12 F 15 A hexadecimal to decimal conversion table is provided in the annex Coding Address H 16 L Addressing examples 15 112 44 Examples for Addressing the EPXPBSOO1 PROFIBUS address 15 H 0 L F PROFIBUS address 112 H 7 L 0 PROFIBUS address 44 H 2 L C For public disclosure RSTi EP Slice I O Profibus Network Adapter 7 GFK 2964 Installation in Hazardous Areas EQUIPMENT LABELED WITH REFERENCE TO CLASS GROUPS A B C amp D DIV 2 HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS D
2. 34 Oom o a aaO ara For public disclosure 4 RSTi EP Slice I O Profibus Network Adapter GFK 2964 Field Wiring The connection frame has one connector and two 24 V DC wires can be connected to each connector along with two ground connections Those four connectors are used as shown in the following figure The Spring style technology allows either finely stranded or solid wire with crimped wire end ferrules or ultrasonically welded wires each with a maximum cross section of 1 5 mm 16 guage to be inserted easily through the opening in the clamping terminal without having to use tools To insert fine stranded wires without wire end ferrules the pusher must be pressed in with a screwdriver and released to latch the wire Connector Block Connector Specifications e conductor cross section 0 14 to 1 5 mm 26 16 guage e max ampacity 10 A e 4 pole The modules do not have a fused sensor activator power supply All cables to the connected sensors actuators must be fused corresponding to their conductor cross sections as per Standard DIN EN 60204 1 section 12 Refer to the RSTI EP Slice I O User Manual GFK 2958 for additional information For technical assistance go to http support ge ip com For public disclosure RSTi EP Slice I O Profibus Network Adapter 5 GFK 2964 Connection Diagrams n n Pat ar r Tan i a i Shi 1 JA waa 2 6lfo9ji 2 a bee A H oF owo s i2
3. Air humidity operation transport 5 to 95 noncondensing as per DIN EN 61131 2 Width 52 mm 2 05 in 7em 2 99 120 mm 72 223 q 1787 od Configuration The GSD file is available on the Support website http support ge ip com for download and import into Proficy Machine Edition The GSD supporting a firmware release is part of the firmware upgrade kit available on the Support website Storage temperature For public disclosure RSTi EP Slice I O Profibus Network Adapter 3 GFK 2964 LEDs LED Status Indicators LED State Description PWA eow LED Green Supply voltage connected Lan Ma ama Red Configuration error or error in the network adapter or error in a module or there is a new diagnostic report Red flashing Station in Force mode Bus fault Red No connection to the fieldbus Red flashing Configuration error no connection to the control unit or error in the parameter set or slave address error or firmware update is running Maintenance Required Yellow Error on the system bus or fieldbus LED Indicators EPXPBSO01 Power Green Supply voltage gt 18 V DC Supply Red At least one current path lt 18 V Green Input current path supply voltage gt 18 V DC Red Input current path supply voltage lt 18 V DC Red Internal fuse defective Green Output current path supply voltage gt 18 V DC Red Output current path supply voltage lt 18 V DC Red Internal fuse defective c U gt 31 MES
4. Digital Output 4 Points Positive Negative Logic 24VDC 2 0A 2 3 or 4 Wire EP 2218 Digital Output 8 Points Positive Logic 24VDC 0 5A 2 Wire EPS225F Digital Input 16 Points Positive Logic 24VDC 0 5A 1 Wire Digital Relay Output Modules EP 2714 Digital Relay Output 4 Points Positive Logic 24 220 VDC VAC 6A 2 Wire EP 2814 Solid state Relay Output Module For public disclosure 8 RSTi EP Slice I O Profibus Network Adapter GFK 2964 EP 3164 EP 3264 EP 3124 EP 3368 EP 3468 EP 3704 EP 3804 EP 4164 EP 4264 EP 5111 EP 5112 EP 5212 EP 5422 EP 5442 EP 7631 Power Feed Modules for Output Current Path Safe Feed input Modules EP 1901 1 Safe Feed Input 24 VDC EP 1902 2 Safe Feed Inputs 24 VDC Programmable Delay EPeigec 2 Safe Feed Inputs 24 VDC Potential Distribution Modules EP ILF Power Module 16 Channels 24VDC Potential Distribution 24 VDC from Input Current Path EP 751F Power Module 16 Channels 24VDC Potential Distribution 24 VDC from Output Current Path EP 00F Power Module 16 Channels 24VDC Potential Distribution Functional Earth EP 10F Power Module 16 Channels 24VDC Potential Distribution OVDC from Input Current Path EP 750F Power Module 16 Channels 24VDC Potential Distribution OVDC from Output Current Path Release History Version EPXPBSOO1 01 00 Nov 2015 Initial Release For public disclosure RSTi EP Slice I O Profibus Network Adapter 9 GFK 2964 Important Product Informatio
5. IVISION 2 GROUPS A B C DOR NON HAZARDOUS AREAS ONLY A WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 A WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS AREAS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES AND A WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS ATEX Marking gt 13 G Ex NA IIC T4 Gc Ta 20 C to 60 C 4 F to 140 F Thermal Derating The power supply is restricted according to the temperature The following values apply for the horizontal and vertical positioning of the RSTI EP station Temperature dependent Values for the Power Supply YT Rorcontat Vera 60 C 140 F 2x8A 55 C 131 F 2 x 6A 55 C 131 F 2 x 10 A 50 C 122 F 2 x8 A Power feed module power supply 60 C 140 F 1x 10A 55 C 131 F 1x8A Refer to the RSTI EP Slice I O Module User Manual GFK 2958 for additional information Network adapter power supply Supported Modules and Power Supplies The following modules can be used with this release of the RSTi EP Profibus Network Adaptor EP 1214 EP 1218 EP 1318 EP 125F EP 12F4 Digital Input 4 Points Positive Logic 24VDC 2 3 or 4 Wire Time stamp EP 2214 Digital Output 4 Points Positive Logic 24VDC 0 5A 2 3 or 4 Wire EP 2614 Digital Output 4 Points Positive Logic 24VDC 2 0A 2 3 or 4 Wire EP 2634
6. RSTI EP Slice I O GFK 2964 Profibus Network Adapter Module EPXPBS001 November 2015 The EPXPBSO01 network adapter is a PROFIBUS DP device certified by the PROFIBUS user organization The network adapter is the head module for the RSTi EP communication bus to which up to 64 active PWR SF BF RSTi EP modules can be connected The PROFIBUS DP network adapter Bus address dials ae Tees has a Sub D socket and supports all services in accordance with the DP V1 specification The network adapter can be accessed with a system independent web server application via the USB service interface Thus all information such as diagnostics status values and parameters can be read and alll connected modules can be simulated or forced The station s main power supply is integrated in the network adapter Power is supplied via two 4 pole connectors separated into the input and output current paths Caution the RSTI EP station is usually installed on a horizontally positioned DIN rail Installation on vertically positioned DIN rails is also possible However the heat dissipation is reduced such that the derating values change refer to the section Thermal Derating Modules should to be allowed to de energize for a minimum 10 seconds after power down prior to starting any maintenance activity The network adapter cannot be hot swapped Refer to the RSTI EP Slice I O User Manual GFK 2958 for additional information Refer to the RSTI EP Power Supply
7. Reference Guide a software utility available on PME V9 00 for detailed power feed requirements Module Features Supports up to 64 active RSTI EP modules Spring style technology for ease of wiring DIN rail mounted Door for Micro USB Port Double click installation for positive indication of correct Profibus Network Adapter installation Built in Web server for diagnostic information and firmware update through Ethernet and micro USB port 2015 General Electric Company All Rights Reserved Indicates a trademark of General Electric Company and or its subsidiaries All other trademarks are the property of their respective Owners 2 RSTi EP Slice I O Profibus Network Adapter GFK 2964 Ordering Information EPXPBSOO1 RSTI EP Slice I O Profibus Network Adapter Specifications TANNA EPXPBSOO1 Connection Fieldbus protocol a Number of modules Configuration interface Fieldbus RISLEP system bus 20 4V 28 8V 20 4V 28 8V 10 A 10 A Transfer rate Supply Supply voltage for system and inputs Supply voltage for outputs Max feed in current for input modules Max feed in current for output modules Current consumption from system 100 mA current path Isys Connection data Type of connection Spring style Conductor cross section Single wired fine wired 0 14 1 5 mm AWG 26 16 General data Operating temperature 20 C to 60 C 4 F to 140 F 40 C to 85 C 40 F to 185 F
8. n for this Release Updates Initial Release Funcional Compatibility Initial Release Problems Resolved by this Release None Initial Release New Features and Enhancements None Initial Release Known Restrictions and Open Issues None Operational Notes None Product Documentation RSTI EP Slice I O Module User Manual GFK 2958 RSTI EP Slice I O Functional Safety Module User Manual GFK 2956 1 800 433 2682 1 454 978 5100 www ge ip com GE Intelligent Platforms For public disclosure
Download Pdf Manuals
Related Search
Related Contents
MS Play Sport Video Support and Upload Directions iHome IH-M151OB User's Manual Abrir BEDIENUNGSANLEITUNG CO2-Messgerät mit Datenlogger Lenmar NVC250, Power Inverter 250W 主剤 夏型 - ダイキン工業 15 mines et travaux de chantier conductrices ClientPro 766Xi/Xe テレコンポーネントライブラリ(形式:TLCOM) 取扱説明書 - M 1Manuel utilisation PROZONE 25012012 Copyright © All rights reserved.
Failed to retrieve file