Catella PACS 5.0 Viewer User Manual
Contents
1. Specify the left X and top Y positions width and height of the measurement line and then select the line color and line style Finally click OK 4 1 22 Area Measurements The Area Measurement Functionality of the CATELLA Software helps you to measure the area perimeter mean min max and standard deviation of the required Rectangular Elliptical Region Of Interest ROI To do this click Z or w button in the Image Review Window and drag the mouse to define a square or rectangle of the required size You will notice a rectangle or an ellipse with all angular measurement values like area perimeter ROI mean etc displayed on the image as shown below Please note he ROI details will be displayed on the image only if the Display ROI Information for Areas Option in the General I Settings Dialog is enabled Refer to General Settings to enable this option The measurement details will appear in the default color and font Refer Annotation settings in 144 to set the default measurement settings 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 36 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T To change the default line and fill color settings and the location of the measurement Area double click the measurement rectangle A Set Properties dialog as shown below will open Set Properties Location and Size Width Height 91 Line Settings Line Color Line
2. Report Status Modality LIER C TYR L CR UNM lowe Lict O us O MG RRR OMR sC Search Local Archive Query EDGEPACS v If you would like to query the study details from a remote DICOM Node click on the button and select the desired DICOM server Please note all the remote nodes that you have added using the DICOM Settings will be listed here Else if you wish to query the study details from the local archive click on this Search Local Archive button Note Clicking on the Search Key Images button retrieves the key images matching the search criteria The nearest match retrieved from the default DICOM Server will be displayed in the Study Details Display Region as shown below Double clicking the desired study detail will enable you to view the corresponding images and to perform various image review operations 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 9 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ai DR S K NIZAMU M 12 16 CT 5377 CHEST 5377 049Y 0 bytes PRECISION Search Custom Search To query the study details based on predefined filters You will notice that all the filters that you have defined using the Filter Settings will be listed as shown in the figure given below Refer to the Filter Settings to define edit or delete a search filter Now click on the desired filter name All the study details matching the selected fi
3. F E s ARCHIVE IMAGE VIEWER PRINT COMPOSER j CD WRITER Ji IMAGE ACQUISITION Preferences al Help Losd Files sex sty uon aces sty study age image stu rte Oeparme Pertornin Rening P Reterra Operator GICOM Directory TENG CT S377 CHEST 3977 0Y 13 gamp Qpem Study INIA TEESE CT i2 6 0 ME 1 2 241 He 10 Write te CD Pic Remote Hode Split Series Write to CD DVD Acquire Image Custom Search Export selected series to disk cT Ma 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 17 paeran A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ A Split Series Dialog opens displaying the list of all the images corresponding to the selected series ff Exam Details Patient ID DR S K RAJAN Patient Name NIZAMUDEEN D A MR Modality Study Desc CHEST Study Date 12 16 2004 Images Count h3 Series Details Series Series Description Series Series UID 2 He 10 mm 1 5 12 16 12 30 CT 1 2 840 113619 2 81 290 26072 Current Series Image List New Series Image List Image Volume Path File Name l Image Volume Path File Name l 2 C Program 30092009 1 1 5 C Program 30092009 1 1 1 C Program 30092009 1 1 3 C Program 30092009 1 1 4 C Program 30092009 1 1 h_ 7 C Program 30092009 1 1 6 C Program 30092009 1 1
4. 8 3 Modality Settings This functionality enables you to set the image layout zoom interpolation image attribute display condition list of overlays to be displayed and window leveling presets for each of the modalities like CR CT MR etc and also allows you to customize the annotation toolbar for a specific modality On clicking the Modality Settings Tab in the CATELLA PACS 5 0 Viewer Application Settings Dialog a Modality Settings Dialog opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 80 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Application Settings Select User Change Preference Password Administrator Annotations Filters Reporting Distribution Acquisition GD vn Cow os se J Cw Cee Cer Cox Cor Cor Image Layout Zoom Interpolation Default l l l l l l Mo Lens Size 120 units l l l l l l l al Lens Zoom Level C 200 300 C 400 Start in WL mode s Customize Toolbar Display Overlays Display in Search Image ordering Ascending Define Overlay List WINDOW LEVELLING PRESETS Edit J Delete oo 0 Abdomen Al Bone 480 Brain B 40 Chest l 40 Head Neck 90 Lung 600 The primary elements in the Modality Settings Dialog are listed below Fields modality modality review window for the modality selected image review window for the chosen modality the image is loaded in the Image Viewer Window Display in Sea
5. Fields Descriptions Portrays the original image Result Portrays the resultant image after image rotation or image flipping process To flip the image horizontally To flip the image vertically To apply customized settings to the image To quit the Preview Dialog without saving the entered details 7 9 1 b Resize Resample Image Lock To lock Preview option If the option is enabled then you will be able Preview to see changes in the Result area as you rotate flip the image This option allows you to resize resample the images To do this 1 Click Ss button and select Resample option from the Drop Down List Or 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 65 ne A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual a Right click the image select Process option from the Pop Up and then select Resample option from the Submenu as shown below Annotate gt Mode gt Process Invert gt Rotate Left 90 Rotate Right 90 Flip Horizontally Flip Vertically Rotate Custom gt 2 A Resize Resample Image Dialog opens as shown below Set the required height and width of the image and click OK Button Current Size 53 x 151 New Size 53 x 151 i Set new size oo t Set new size as percentage of original Width 100 Height 100 Preserve aspect ratio M sampling Filter The fields in the Resize Resample Image Dialog are described
6. AMD Technologies Inc 218 Bronwood Avenue Los Angeles CA 90049 3104 T 310 470 8900 T 800 423 3535 F 310 471 8900 W digitalams com W ams4illuminators com E catella_support digitalams com Catella PACS 5 0 Viewer User Manual Revision History Revision Description Verified by es S LS 7 1 2010 Initial Draft A D A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Contents Chapter 1 Introduction beket e EE a i E E N E E E vile E E E R A 5 2 We LOJI e ee E EEE a epoca eee ae ss eee ee a 6 2 2 Getting familar With Te Main SGre iieri eee TE E diia TEE EE ele 6 3 1 Query from the DICOM Server or Local Archive ccccccceeceeeeeeaaeeeseeeeeeeeeeeeeeeeeeaaaaaseaedeeeeeeeeeeeeeeeaaaaaaageeeeeeeeeeeseeseeaaaaaaaeeess 9 s2 ote 1 1 FIE ee E E E E E T S A nee eer 11 SISO HEE OMDR ae A E N E A neta eseeeemenenes 11 wA Edt Paen and NS UIN sosi EE A a E E E 12 Lo OE OV e E E E E E E O A 13 So Pal 21 0 cacy E a ne ee ene E E ee eee 15 OM OTS acts r eee getenace pane yaawvane ence ances seam ane E E EA E E E AEE AA E A OR 17 FRS IS E E EE E N E E E E A E E A E E AE E E E decane E E 19 iS eo Bowo d UNE searre EEE EEEE 20 3 10 Expor Selected Study Seres to DISK cides cesncncscces snes cticadatatdeaGonsuaeadasssdundnte dic EEN EESE ENESE ESERSE EEEE 21 TE De U r E E E E E A O E A O E E E T 21 chani Tra TOE V EWE eeen e E E a eee 22 AT Mie VONE NEON a e N E IE E T E E O E E O E ETE 22 4 1 1 Deselec
7. The table listed below gives a quick overview of various annotation tools available on the Annotation Screen Click To p gt ee Gimme See Set m poeroen ONC TE Type text on the image lo Change the brightness of the image lon Change the contrast of the image om Crop the desired portion of the image ic a Invert the image To rotate the image left or right and to flip the image horizontally or i vertically DO Deskew the scanned image and report Save the annotations made on the image as Return to the Import Screen Refer to other sections to set the properties of the line rectangle circle polygon and the text included in the image 7 9 1 How to mark annotations on the image The table listed below describes the procedure of making various annotations on the image Deselect the Click button selected annotation Or tools Right click the image and select Annotation gt Deselect from the Pop Up Pan the image wh Click button Or Right click the image and select Mode gt Pan from the Pop Up Left Click and drag the mouse pointer on the image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 60 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee Draw line on the image Draw arrow on the image Draw rectangle on the image Draw circle or ellipse on the image Type text on the image Change the brightness of the image Change the co
8. 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 95 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Note When the job spans more than a disc the job will be written onto multiple discs depending on how you have chosen to split the job based on the study series or image level CD Label Settings Next to add edit delete a CD Label file click the CD Labels button in the PRIMERA Setup Dialog which pops up a Media CD Labels Dialog Note The CD Label file has a file extension of btw The CD Label has to be designed using a CD Designer Application that comes with the PRIMERA Installer Media CD Labels Label File List Field List Del Group Edit C General The Default CD Label will be displayed in the Label File List Double clicking the Default Label name enables you to edit the CD Label in the CD Designer Application To add a new CD Label File 1 Click the Add button A Label File dialog opens as shown below Re ee A Description Filename C Users Sangeetha Desktop sangi c btw 2 Specify the Description of the CD Label file Then click I button and locate the CD Label file using the Open Dialog 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 96 es A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T 3 Then select the General and click on the Add button in the Fields List Panel of the Media CD Labels dialog A Label dialog opens Caption Pat
9. Default label for anonymized job Label 1 Define Labels I AiE Select the available storage media either as CD or DVD Enabling Use DVD if jobsize exceeds CD capacity option helps you to write the selected job onto a DVD if the job size exceeds the CD capacity Note This option is enabled only when you select the Available Media as DVD Select the Job Split Level either as a study level or a series level or an image level Then select the default CD Label for Single Study Job Multiple Study Job and Anonymized Job Note When the job spans more than a disc the job will be written onto multiple discs depending on how you have chose to split the job based on the study series or image level CD Label Settings Next to add edit delete a CD Label file click the Define Labels in the DUET Setup Dialog which pops up a Media CD Labels Dialog Note The CD Label file has a file extension of cdl The CD Label has to be designed using a CD Designer Application that comes with the Catella Workstation Installer You can fin the CD Label application DuetLabelDesigner exe at C Program Files AMD Technologies Inc Catella Workstation which is the installed location 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 99 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Media CD Labels Label File List C Documents and Settings Sangi Desktop Labelt cdl Field List Del Group J Add H Edit Bal
10. To do this 1 Click on the Customize Hot Heys button under General Settings 2 Adialog showing default shortcut keys for various function of the application opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 79 ay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual aaa Customize Hot Keys Lock Application Shift Ctrl L Global Preference Ctrl P Global Send Image Viewer to Next F3 Global Toggle Full Screen Fii Image Viewer Pan and Zoom Mode Image Viewer Lens Mode Image Viewer Hounsfield Mode Image Viewer Line Drawing Mode Image Viewer Arrow Mode Image Viewer Rectangle Mode Image Viewer Ellipse Mode Image Viewer Text Mode Image Viewer Window Level Mode Image Viewer Pan Right Mouse Button Image Viewer Zoom Left Mouse Button Image Viewer Invert l Image Viewer Reset Level and Orientation F2 Image Viewer Send To Print Composer F5 Image Viewer Rotate Left Ctrl Right Image Viewer Rotate Right Ctrl Left Image Viewer Flip Horizontal Shift Right Image Viewer Alternate Flip Horizontal Shift Lett Image Viewer Flip Vertical Shift Up Image Viewer Alternate Flip Vertical Shift Down Etl Shit L Set Save Save Cancel Select the function whose keyboard shortcut you wish to change Then press the required keys simultaneously and click on the Set Button Similarly repeat the procedure for all the functions whose hot keys you wish to change and finally click on the Save button
11. outside the defined cropping region To crop the image 1 Click im button Or Right click the image and select Mode gt Crop from the Pop Up Process gt IN Brightness i Zeem Ecntrast 3 Select an area to crop by drawing a frame around the area that you want to retain as shown below Move the selection rectangle with the mouse if necessary or change the size of the selection rectangle using one of the grab tabs around the edge To deselect the selected area click outside the selection rectangle Press Enter key in the keyboard 4 The area outside the drawn rectangle is cropped or discarded as shown below Click Save button to save the cropped image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 63 a A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual CO 7 9 4 Invert Rotate and Flip Image You can use the Rotate amp Flip options to flip or mirror the entire image and to rotate the image according to the number of degrees specified You can also view the negatives of the image using the Invert option The table listed below gives a quick overview of the procedure to invert rotate and flip the images Click button and select Rotate Left 90 option from the Drop Down List Or Right click the image and select Process gt Rotate Left 90 from the Pop Up Rotate Image to Left by 90 Degrees Click button and select Rotate Right 90 option from the Drop Rotate Image to Right Dow
12. when you click on window level button Pressing Shift Key in the keyboard and the window level button simultaneously helps you to apply the appropriate operation only to the selected image After adjusting the window level of the image right click and select Save Presets to save it as new window level presets for the particular modality to which the image corresponds 4 1 6 View Hounsfield of image To view the Hounsfield of the image 1 Click button Or Right click the Image Review Region select Mode gt Hounsfield option from the Pop Up Or Click the H key in the keyboard 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 27 Bees A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ___ 2 Left click and drag the mouse pointer over the image to view the hounsfield of that image portion 4 1 7 How to Draw This section describes the procedure to draw a line arrow rectangle or ellipse on the image Draw a line on the image 1 Click button Ofr Right click the Image Review Region and select Mode gt Line from the Pop Up Or Press the L key in the keyboard 2 Left click and drag the mouse to draw a line on the image Draw an arrow on the image g 1 Click button Or Right click the Image Review Region and select Mode gt Arrow from the Pop Up Or Press the A key in the keyboard 2 Left click and drag the mouse to draw an arrow on the image Draw a rectang
13. 0 PACS Viewer User Manual A D AMD Technologies Inc Write the selected studies onto the CD CD WRITER Print the selected images using the DICOM Printer or any other network printer i Convert the secondary captured non DICOM images to IMAGE ACQUISITION DICOM images Carry out various functionality settings like Password Modality Specific Settings Annotation DICOM Nodes Image Acquisition and Filter Settings 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 8 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 3 Query and Load DICOM Files CATELLA PACS 5 0 Viewer offers you the functionality to query and retrieve the Study details that you want from the default DICOM server and the local archive You need to set the default DICOM node before the query process Refer to preferences DICOM settings 3 1 Query from the DICOM Server or Local Archive To query Study Details using the advanced search option 1 Click on button A Custom Search Dialog as shown below opens Specify any one or a combination of the search criteria like patient name ID sex modality study date accession etc in the corresponding fields Custom Search e Patient Name Study Description Patient ID Accession No Patient Sex Oat OMOFOO Referring Physician Study Date From To Institution Name Date Filter 9 30 2009 a 9 30 2009 v
14. 1x1 X Default Store Server Default Query Server Default DICOM Printer Display Thumbnails Display Scout Lines Burn viewer to CD Reset mode after annotating Display ROI Information for areas Retain hounsfield labels on mouseup Y Add Imported Files To Archive v Auto logoff interval o W minutes Select 0 to disable Change Password Customize Hotkeys The fields in the General Settings Dialog and their descriptions are listed below PIO JE potion Series Layout Select the series layout for Image Review windows Select the default Store Server Default Store Server Please note all the DICOM nodes that the administrator has added using the DICOM Server Settings will be listed here Select the default Query Server Default Query Server Please note all the DICOM nodes that the administrator has added using the DICOM Server Settings will be listed here Select the default DICOM Printer Default DICOM Printer Please note all the DICOM Printer that the administrator has added using the DICOM Server Settings will be listed here Select this option to view the thumbnails of image series loaded in the Image Viewer Screen the images onto the CD DVD annotating immediately after the annotation process Display ROI information Check this to view the information like perimeter area for areas mean etc of the Region of Interest ROI Add import
15. CSS GE GNM e Seas A Worklist l Clear All ma a DESELECT ALL oq P meor DELETE SELECTED 6x6 Write DICOMDIR To add new patient information follow the procedure mentioned below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 51 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual 1 Inthe Patient Data Frame the patient ID is generated automatically You can change the patient ID if required Then specify the Name Sex Age or Date of Birth Phone number and Address of the patient 2 Inthe Study Data Frame specify the Study time Study date Study Description Accession Number and Study ID Note The system date and time will be displayed as the study series date and time by default If you wish you can change the study series date and time 3 Next select the Modality like US CT MR NM OT and SC and specify the series description Note The default Modality is SC secondary captured The Patient Name and Patient ID are mandatory fields 4 Now click on the import button or capture button to import or capture the images to the patient record Note Right clicking and Choosing Add New Studies helps you to add a new study for the selected patient To add a new series for the patient right click and choose Add New Series 7 3 Query From DICOM Server This option allows querying studies from any DICOM server or the local archive using any or a combination of the search criteria like na
16. Det General The Default CD Label will be displayed in the Label File List Double clicking the Default Label name enables you to edit the CD Label in the DUET Label Designer Application To add a new CD Label File 1 Click the Add button A Label File dialog opens as shown below Label File Description Label 3 Filename C Documents and Settings SangiiDesktop ihe em f Cancel 2 Specify the Description of the CD Label file Then click base button and locate the CD Label file using the Open Dialog 3 Then select the General and click on the Add button in the Fields List Panel of the Media CD Labels dialog A Label dialog opens a Eee 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 100 ay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ Note General Text in the Fields List Panel represents the First Study 4 In the Caption Edit box enter the merge field name say for example Patient Name that you have specified in the CD label file Select the corresponding value and click OK button This enables the application to print the value corresponding to the specified Merge Field Name onto the CD 5 Repeat 3rd and 4th steps to assign a value to all the required merge fields in the CD Label File for a single study 6 To include multiple study details click button in the CD Labels dialog A Label dialog pops up Enter the merge field name say for example Pa
17. Doc 340 3 503 Rev 01 Page 38 Catella 5 0 PACS Viewer User Manual Right click the image and select appropriate preset name from the Pop up You will notice that the window width and level of the image being adjusted based on the selected preset You can also apply a Window level and save the preset by clicking on the image and selecting Preset gt Save Preset and giving a name Please note that all the presets corresponding to the modality will be listed in the Popup Refer to Modality Settings for adding or editing the presets 4 1 26 Stitch Images CATELLA PACS 5 0 Viewer Application allows you to join two or more images of the selected series of a study into a single image To do this choose the images that you wish to join from the Image Review Window and right click and select Stitch Selected Images Reset Level and orientation F2 Select all images Cirit A Delete Presentation state Customize hot keys Send to remote node Send to composer Quick print Export images to powerpoint Create AVI file from series Hanging Protocol Hanging Protocol List Stitch selected images ce B An Image Stitching Dialog displaying the chosen images opens as shown below n Image Stitching 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 39 pay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T Select the image and make required annotations using variou
18. Hepatic vems are enhancing after the contrast administration Both ureter are normally visualised Stomach Ascending colon transverse colon Caecum and Descending colon are normal Small and large bowel coils are normal No evidence of any para aortic or iliac lymphadenopathy z Enter the Template name Then select the modality and category to which report applies If you want the report template to be visible to all users check the Public checkbox Then type in the necessary report details and change the font settings of the text using the Formatting Toolbar if required Once you are done with the report preparation click on the OK button to save the report Template To Edit the report Template Select the Report Template name and Click on the Edit button in the Reporting Dialog Make the required changes in the report template Then click on the ok button to save the changes 9 3 How to design a new Report Header To design a new report header Click on the Header Designer button in the Reporting Dialog A CATELLA PACS 5 0 Viewer Report Designer Window as shown below will open 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 109 Te A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ___ ee AipReport Header Designer Center Information Patient Information _ Letterhead SS0SS0006E8ESEER0EE AMD Technologies Inc 218 Bronwood Avenue Los Angeles CA 90049 USA
19. Printer Settings cccssssssssseeeeeeeeeeeeeeeeaneeessseeeeeeeeeeeeeseeeaaaeasaseeeeeeeeeseeesseaaaaggaseess 71 Sg ASS IE TCSII a E ccmmer ep sc abet occinncn ap scatien se ccmmanen seaman cacencmen sanden sc ucmmoren sequen oacennmen saetenntacianeneosasites 73 8 1 9 Backup Seting essri e E ES nS ee mr EEE E E NESA 75 015 aimp coniguraton SENGS aera eee eee enc mn E rere eee errr ee oreo 76 8 1 5 b Expor Configuration SUING S sossen EENE E AR ATENa ENAA RR A 76 BOG OU See Sp Ge II ss jensskden aauledioanedaletiencucnde R E T E E T 76 A ee SUIS eean RERA EREEREER ENERE 77 e IPOE O GY a E E O E E EE E E A E OT 79 eRe A os NEY E E E EE A E E A E E E A E EE A E E E E E A E 80 8 3 1 HowtoAdd Edit Delete PIeS lS 7 trc ssevncecsvisssissaureesvsrmsantenai reissue ten arene eee eee 82 8 0 25 OMS IOMMIZe AmMolalon WOOD AN toca xtc 2c ces cee cesta T AT T 82 8 3 3 Define OverlayS act ase acs sce accra AEREA A AREARE AAE cance aaciensaaieanessantacisseeasciesaceaaanaeaaeseaaeeaese ade oesaaenmeeasesacessetaua 86 tome ie ee ali 01 6 ene eee E eR Ree E eee ee eee ener eee ee errr 87 SES FIET E 6 een nee ee meet ea eve no ee rr en eget ec eae ree ere eee ee 88 8 6 CD DYD DistipUton SEWING eeeeeepenee te ketene nen meet E ene tn te ener erie wane nene ener fee errr oer tener weer 90 8 6 1 Configure Local CD Burner Gaummmenn eters mene mentees Santen tenet ttl Mears arse tre fer ner iat ne ene erent oe ere er ee een eee ee eee 91 8 6 2 Con
20. Right click on the Image Review Region and select Mode gt Pan Zoom from the Pop Up Left click and drag the mouse over the image to zoom in or out the image To pan the image right click and drag the mouse Please note you can use the scroll button if available in your mouse to zoom the image in or out To zoom a specific region of an image Right click the Image Review Region and select Mode gt Pan Zoom Left click and drag the mouse over the image Refer to Modality Settings to set the zoom window size and zoom percentage All images in the current page of the Image Viewer will be zoomed when you click on zoom button Pressing Shift Key in the keyboard and the zoom button simultaneously helps you to apply the appropriate operation only to the selected image 4 1 3 Rotate Flip and Invert Image The table listed below gives a quick overview of the procedure to invert rotate and flip the images Click button Or Right click the Image Review Region and select Processing gt Rotate Left option from the Pop Up Or Click Cirl lt keys in the keyboard Click Button Rotate Image to Right by or 90 Degrees or clockwise Right click the Image Review Region and select direction Processing gt Rotate Right option from the Pop Up Or Rotate Image to Left by 90 Degrees or anticlockwise direction Click Ctrl gt keys in the keyboard Click Button Or Flip Image Horizontally Right click the Image Review Reg
21. To Archive mee BR ce 6 DESELECT ALL 3x3 IMPORT DELETE SELECTED 5x5 pels O iescriptions O O i Option to input Patient Name Patient ID Address Sex Age or Patient Details l Date of Birth and phone number Study Details Option to enter Study Date Study Time Accession Number study description and study ID Series Details sda to specify Series Date Series Time Modality and escription 2x2 Save To Disk 6x6 Write DICOMDIR To query patient details from a DICOM server based on the search criteria like name study date ID accession modality or sex of the patient To get patient details from the modality worklist server based on search criteria such as name scheduled date ID modality sex and accession number 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 50 aaa A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Raa Clear All Clears all the data and images corresponding to patient IMPORT To import the Non DICOM image files to a current patient record Option to scan and associate old patient reports or any other documents like Driving license insurance details etc with the current record of the patient Option to capture single frame images or cine loops for the patient To scan the films like X ray films ex using Vidar scanner 7 2 Add Patient Information M CES
22. User Manual w 3 5 Split Study This option of the CATELLA PACS 5 0 Viewer Application helps you to split a study with multiple series into two different studies This feature is applicable only for the images queried from the local archive To do this select a required study from the Archival Screen of the Application and right click and choose Split Study F o E ma I PT mpi ay IMAGE VIEWER Jf PRINT COMPOSER i CD WRITER jf IMAGE ACQUISITION Load Files DICOM Directory Open Study Write to CD View Report elect Remote Node Search Custom Search You would notice a Split Study Dialog listing out all the available series of the selected study on your screen 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 13 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Split Study Exam Details Patient 1D ASAN Patient Name _ NIZAMUDEEN D A MR Modality Study Desc CHEST Study Date 12 16 2004 images Count Current Series List New Series List Series Series Desc Series Series Series Series Desc Series Series AP Scout 12 16 12 30 He 10 mm 1 5 12 16 12 30 il b Now select the series that you wish to include in the new study from the Current Series List Frame Note Use the Ctrl Key in the keyboard to choose multiple series Button Click To Move
23. below Fields DESCRIPTIONS __ _ _ _ _ _ _ _ Enabling this option helps you to set new width and height of the image Set New Size Note This option is disabled when the Set new size as percentage of original option is enabled Enabling this option allows you to set the new size of the image as percentage of current size of the image The height percentage will change relative to the width percentage while vice versa is not possible Note This option is disabled when the Set New Size option is enabled Preserve Aspect Enabling this option helps you to adjust the height and width relative to Set new size as percentage of original 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 66 CEN A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Ratio each other automatically for Set New Size option and to adjust only the height with respect to width for Set new size as Percentage of Original option __ ee Describes the sampling filter of the image Sampling Filter Note Filter is used to maintain the quality of the image while enlarging the image To apply current settings To quit the Resize Resample dialog without saving the entered details 7 9 3 Zoom You can change the magnification zoom percentage of the image to make the image more readable on the screen To magnify the image right click the image and select Zoom option from the Pop Up The
24. click Edit button in the Media CD Labels dialog Make the required changes in the Label Dialog and click OK button 8 Todelete the merge field name select the required merge field name and click Delete button in the Media CD Labels dialog as shown above 9 Todelete the Study select the appropriate study say for example Study1 from the Fields List Panel and click on the Delete Group button To edit or change the CD Label File List Select the Label name from the displayed list and click the Edit button in the Label File List Panel A Label File Dialog opens Make the required changes in the description and filename and click OK button Note The default label s description cannot be edited To delete the CD Label File from the List Select the Label name from the displayed list and click Delete button A Confirm Dialog as shown below will open Click Yes to continue RIMAGE Interface Settings Click button to start the Interface service between the CATELLA application and the RIMAGE Setup To stop the RIMAGE Interface Service click D button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 94 paeran l A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Clicking button refreshes the RIMAGE Interface Service Click View Current Log button to view the operation log of the PRIMERA Interface Service 8 6 3 Configure PRIMERA for CD DVD writing To configure the Primera Check the PRIMERA check b
25. dots per inch Select the color Acquire Frame inch To define the frame size of the scanned document Negotiate Parameter To negotiate default parameters To acquire the scanned images to the CATELLA software Click Acquire button to acquire the scanned image reports Once scanning is completed the scanned image report appears on the Import Screen Double click the scanned image report and mark the annotations on the scanned image report using the various annotation tools available in the Annotation Screen 7 8 Film Scan This option helps you to scan a film like X ray using any film scanner like Vidar Scanner and associate it with the current study If you wish to use this functionality click on the FILMSCAN button in the CATELLA You will notice a Vidar Interface Dialog as shown below pops up on your screen 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 56 ees A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual CON The table given below gives a quick overview of all the fields available in the above dialog Fields _ Descriptions Start Scan Starts the film scanning operation The default staging mode of the scan operation is MANUAL The default mode can be changed by setting the ScanStageMode property Ejects the medium from the film scanner Calibrate Calibrates the scanner with respect to the default settings of the CATELLA software 7 8 1 Set Film Scan
26. image resolution in pixels per inch Scan Stage Mode The ScanStageMode property sets the operation of the film scanner in either manual or automatic mode In the manual mode only one film can be scanned for each scan request In the auto mode it is possible to scan more than one film Translation Table Sets the current translation table Dark Enhance Turns the dark enhancement feature on or off The dark enhancement feature lightens of increases that contrast in dark areas of an image Image Height The film scanners cannot detect the height of a film prior to a scan so we set the height to a maximum default value of 17 inches The maximum height of a film that can be scanned can be changed using the MaxlmageHeightInInches property The value of the ImageHeight property before a scan will give the maximum height of the film that can be digitized Image Width Gets the image width of the film scanned Scanner ID Gets the film scanner type currently in use Scanner Serial Gets the film digitizer serial number Scanner Firmware Version Gets the film scanner firmware version Scanner HW Version Gets the film scanner hardware version number Scanner RAM Size Gets the film scanners RAM size in 16K blocks SCSI ID Gets the SCSI ID of the film digitizer SCSI Version Gets the SCSI version 7 8 2 How to scan a film Toscan a film Click on the Film Scan button in the CATELLA Screen which will be followed by a Scanner Interface Di
27. images are of the same size 2 The file size and quality of the avi depends on the compression selected The Microsoft MPEG 4 Video Codec is the recommended compression type 4 1 18 Quick Print Image This functionality helps you to print the selected images using a Windows printer To print the selected image 1 Right click the Image Review Region and select the Quick Print option from the Pop Up A Quick Print dialog will appear Images 1 per page f Images 2 per page f Images 9 per page f mages 4 per page C mages 12 per page Display Border Print Cancel 2 Choose the number of images to be printed per page This option allows images to extend to multiple pages Note The Preview option is not available for the same Ensure that you have selected the right images 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 34 CER A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Se 3 Next click on the Print button 4 1 19 Send Images to Remote Node This option enables you to send all the selected images to the selected remote DICOM node To do this right click and choose Send to Remote Node and then select the desired remote node Please note 1 This option is enabled only for the images queried from the local archive 2 To select a sequence of images press the shift key in the keyboard and use the mouse to select the images 3 If you wish to select random image
28. name and enter the volume label Then click on the Write to CD button If you were set up to use the RIMAGE or PRIMERA for CD DVD writing then all the queued jobs would be automatically written to the CD DVD Note The Write to CD button is enabled only when you had set the Writing Preference as Local CD burner Right clicking and selecting Purge Job removes the selected job from the CD DVD Writing queue To resubmit the job that has been deleted or the job whose writing is abandoned due to some errors as when RIMAGE or PRIMERA runs out of CD DVD s right click and select Resubmit Job 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 49 meee A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 7 Image Acquisition CATELLA PACS 5 0 Viewer enables you to convert secondary captured non DICOM images into DICOM images and transfers converted images to a DICOM server It also has the functionality to associate the scanned images or reports with the patient study data 7 1 Getting Familiar with the Image Acquisition Module This section gives you a quick overview of the primary elements in the Image Acquisition Screen When IMAGE ACQUISITION a you double click the button in the CATELLA PACS 5 0 Viewer Application a screen similar to the one shown below will appear ama CEA IMAGE ACQUISITION mi Clear All Study Date 4 2 2008 v Study Time 9 07 55 AM n ion Save
29. of the Elliptical Region of Measurement Interest ROI of the image Rectangular Area Read the area of the Rectangular Region of Measurement Interest ROI of the image Angle formed between a line drawn parallel to the superior endplate of one vertebra Cobb Angle above the fracture and a line drawn parallel to the inferior endplate of the vertebra one level below the fracture Line with Midpoint Draws a line with the mid point highlighted 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 24 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual D Creates an arc and indicates the arc degrees and the leght of line between the start and stop point Single line will be made like a line but when user releases at the end point the line Horizon Angle displays across the entire film The dangle that is displayed is the degrees of this line to a horizontal line Start with using the same process as a hortizon line User picks a point in the line and pulls up or down from this point to create a perpendicular line Both the horizon angle and length of the perpendicular line are displayed Holding the end of the perpendicular line will allow the T to be moved or rotated Horizon Orthogonical Angle Bi Pleses L and R labels on the Phi ior naa First p aa ntact Phi ior naa is L and second label is R Press the down area next to this button to display the choices Cervical C1 C7 Thora
30. on your Image Viewer Window CEN wace viewer wa Dgan pcpongacpo oguggaon B GH OF S088 SES CHEST 12 16 2004 Please note that the Thumbnail Window will be displayed only if you enabled the Display Thumbnails Option in the General Settings 3 4 Edit Patient and Study details This Application gives you the option to edit the demography and examination details of the studies that are queried from the local archive To access the functionality Right click on the study that you wish to edit and select Edit Patient Study Details from the Pop Up A Dialog as shown below pops up on your screen Make the required changes in the patient and study details and click on the Update button Please note that the changes you have made will be updated in the local database and will be reflected in all the image series corresponding to the study A Edit Patient Study Details gt Patient Details Patient ID DR S K RAJAN Race Alternate ID Street Patient Name NIZAMUDEEN D A MR State Patient Age 049Y Country Patient Sex OmMOFOO Phone Patient Alias Religion Examination Date 12 16 2004 Accession Time 12 35 13 PM ID Description CHEST Advanced Status 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 12 A I AMD Technologies Inc Catella 5 0 PACS Viewer
31. overview of the primary elements in the main screen of the CATELLA PACS 5 0 Viewer 2 1 Login To log into the CATELLA PACS 5 0 Viewer before it has been configured you have to log in as the administrator The administrator is the default user with all rights to configure the application Refer Users to add new users and to change the administrator password Note This product is designed to run at a screen resolution of 1280 by 1024 pixels or higher To log into the application 1 Double click on the CATELLA PACS 5 0 Viewer Icon located on the Desktop or click Start gt All Programs gt AMD Technologies gt CATELLA gt CATELLA PACS 5 0 Viewer A Login dialog as shown below appears on your screen AD Catella Workstation Login E Remember 2 Select the user name and enter the password in the Password edit box Click the Login button Note 1 When you log into the software for the first time you can login into the software as Admin 2 The password for the Admin is admin 3 You can change the password if required Only the administrator has the rights to change the password Refer to Administrator settings for details 2 2 Getting familiar with the Main Screen This section gives you the overview of all the key elements available in the CATELLA PACS 5 0 Viewer Main Screen When you double click on the CATELLA PACS 5 0 Viewer icon a screen similar to the one shown below will appear 2010 AMD Tech
32. right clicking and selecting Delete studies 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 21 lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ Chapter 4 Image Viewer CATELLA PACS 5 0 Viewer enables you to perform various annotations markups on the image using the annotation tools and pop ups and to save the annotations made on the image This chapter describes the annotation tools and how to use them 4 1 Image Viewer Overview To annotate the image 1 Double click the desired study from the queried list of studies or select the desired study and click Open Study Button An Image Review Screen opens displaying the images in the default series layout Refer General Settings to set the default series layout 2 COUELLA DOCS Sera MAGE Viewer CMa Ga CUT m NIZAMUDEEN D A MA DR S K RAJAN CHEST 16 Dec 04 X X AP Scout CT He 10 mm 1 5 CT CHEST 12 16 2004 He 10 mm 1 5 Images 8 8 Thumbnails Show x 049Y DR S K RAJAN NIZAMUDEEN D AMR l Series layout BOBS Now to carry out various annotations on the image double click on the desired frame of the image series and make the annotations on the image Once you have marked the required annotations on the image click on the Save button to save the annotations marked on the image Please note The annotation tools of the Image Review Screen are enabled only on selecting an image Thumbnail Window will be di
33. the Media CD Labels dialog Make the required changes in the Label Dialog and click OK button 9 To delete the merge field name select the required merge field name and click Delete button in the Media CD Labels dialog shown above 10 To delete the Study select the appropriate study say for example Study1 from the Fields List Panel and click on the Delete Group button 10 To edit or change the CD Label File List 11 Select the Label name from the displayed list and click the Edit button in the Label File List Panel A PRIMERA Label File Dialog opens Make the required changes in the description and filename and click OK button Note The default label s description cannot be edited 12 To delete the CD Label File from the List 13 Select the Label name from the displayed list and click Delete button A Confirm Dialog as shown below will open Click Yes to continue 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 98 ease A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T 8 6 4 Configure DUET for CD DVD writing To configure the DUET Application Settings Select User Admin ii Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition LOCAL CD BURNER RIMAGE PRIMERA DUET l 650 MB 74 Mins E Default label for single study job Label 4 7 Default label for multiple study job Labeli
34. the User Details Dialog Note For a normal user the username is restricted from editing 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 74 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual In the case of the administrator and the default user both the user name and the role are restricted from editing To delete the user Select the desired user and click on the Delete button 8 1 5 Backup Settings This functionality of the CATELLA PACS 5 0 Viewer Application helps you to schedule the data backup services and to manage the data backup process of the application To access this feature click on the Administrator gt Backup Tab in the Application Settings Dialog A dialog similar to the one shown below opens Application Settings Select User Admin ad Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition DICOM Server Backup Storage Management Scheduler Service g View Current Log Housekeeping Service is stopped Backup Management Import Configuration Settings Export Configuration Settings Backup Database Now Backup and Restore Schedule Backup Click To Start the backup services Stop the backup services Refresh the backup service Carry out housekeeping settings like how frequently the running process needs to be refreshed View the operation log of the CA
35. the chosen series from current series list frame to new series list frame Move all the series from current series list frame to new series list frame 4 Move back the chosen series from new series list frame to current series list frame Move back all the series from new series list frame to current series list frame Finally click on the Split button You will find a new study with selected series displayed on the Archival Screen as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 14 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Preferences Feb A Load Files rag a column header here to group by that column i Image Study Institution Departme Performin Reading P Referral F Operator DICOM Directory n OST Oe E in A cl al el ca OE Search Custom Search 3 6 Merge Studies CATELLA PACS 5 0 Viewer Application offers you the functionality to merge two or more studies into a single study It is applicable only to studies queried from the local archive To do this choose the source study that you wish to merge from the Archival Screen and right click and select Merge Studies 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 15 i A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual A Merge Studies Dialog opens listing the studies matching the source study attributes Select the studies that you wish to merge with t
36. the image to a New Presentation file 4 To insert the image to an existing presentation click Insert to File option An Open dialog will be displayed Select the file and click Open button Note The option above will work only when Microsoft PowerPoint is installed in your system If you close CATELLA PACS 5 0 Viewer before saving the PowerPoint presentation then PowerPoint will be closed automatically 4 1 16 Select All Images This option is used to select all the images for the quick print option to add the images to the print composer window to create avi and to send the images to the remote DICOM node 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 33 ene A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Oo ERE O To select all the images displayed in your Image Review Window Right click on the image and choose Select All or press Ctrl A keys in the keyboard Note To select random images press Ctrl key and select desired images using the mouse 4 1 17 Create AVI file This option allows you to create an avi file by merging the selected image series To do this right click the image and select Create AVI File from Series option A Save As Dialog opens Enter the file name and click ok Then a Video Compression dialog as shown below will open Select the compression type and click OK i Compressor Full Frames Uncompressed fig E Note 1 The avi can be created only when the
37. the mouse over the image with the button being selected 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 45 lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual as You can change the window level of the selected image by clicking on this g button and left clicking and dragging the mouse over the image To print only a certain circular or rectangular area of the image click on these wa ANS Shutter buttons respectively and drag the mouse over the image You will notice only the image area that you have defined being displayed as shown below Note To remove the shutter i e to view the entire image right click the image and select Remove Shutter Click button to get the mouse pointer or to deselect selected button zoom and pan button window level button and shutter button Note The window leveling zoom and shutter options will be applied to all the images in the page when you click on the appropriate buttons Pressing Shift Key in the keyboard and the window level zoom shutter buttons simultaneously helps you to apply the appropriate operations only to the selected images Navigate Options Buttons Click To Moves to the first page El E Navigate to the next page B Navigates to the previous page Moves to the last page Clears the images in the current page Delete current page Deletes all pages Page Options Right clicking the image and selecting Page Options gt Cut cu
38. to select the CD DVD Writing Options either as Local CD Burner RIMAGE optional or PRIMERA optional for writing the queried study details from the local archive onto the CD DVD To do this Click on the Preference button in the CATELLA Screen and then choose the Distribution Tab in the Application Settings Dialog as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 90 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Application Settings Select User Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition LOCAL CD BURNER RIMAGE PRIMERA Host LOCALHOST Server ID PS01 Port 2 506 cD 650 MB 74 Mins Covo use DvD if size gt co plit job at Study Level Y Anonymization List Job Filter Settings 8 6 1 Configure Local CD Burner For writing the selected studies onto the CD DVD Check the Local CD Burner Option and click on the Save button 8 6 2 Configure RIMAGE for CD DVD writing Check the RIMAGE check box The Host Edit box will display your machine name or Internet protocol IP address by default as shown below You can change the default host name if required Application Settings Select User Admin bg Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquis
39. which the jobs of different status completed queued etc are sorted and displayed in the CD Writing Window A Job Display Options Dialog similar to the one shown below will appear on clicking button in the Application Settings Dialog 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 102 a A D AMD Technologies Inc ____ ee Assembling Queued In Progress Completed Error Deleted Cancelled lt S K x x J J r Job Display Options Group jobs by status Display jobs with status 0 displays all records Display jobs completed in past Display jobs in error in past Display jobs deleted in past Display jobs cancelled in past Save Cancel Catella 5 0 PACS Viewer User Manual The table below gives you a quick overview of all the fields available in the Application Settings Dialog p Fietds Description Group Jobs by Status Enabling this option helps you to group the jobs based on their status such as assembling queued completed etc Display jobs with status Assembling Check this option to display the jobs under assembling status in the Queue Status Window Enable this to display the queued jobs in the Queue Status Window Check this to view the jobs in progress Completed Check this to view the completed jobs Error Enable this option to display the jobs whose burning process is intervened because of some errors like deficiency of CD DVD in the RIMAGE uni
40. width z Line Style Solid Line Fill Settings Transparent Specify the left X and top Y positions width and height of the measurement rectangle Then select the line color line width and line style and also the fill color and fill style of the rectangle Check the Transparent Box if you wish the image to see through the background color of the measurement rectangle Finally click OK 4 1 23 Angular Measurements The Angular Measurement Functionality of the CATELLA Software helps you to measure the angle between between different points of the image Please note only the angle between 0 180 degrees can be measured To do this click button in the Image Review Window or right click on the image and select Mode gt Angular Measurement Drag the mouse on the image to define a base line and then click at the end of the base line and drag the mouse to a desired point You will notice the angle defined between the two lines being displayed on the image as shown below tii m 4 O E yo 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 37 A D 4 1 24 4 1 25 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Please note the measurement details will appear in the default color and font Refer to Annotation settings to set the default measurement settings Image Histogram This feature of the software helps you to view the image histogram which plots t
41. 0 PACS Viewer User Manual oOo SREE Downloads Patient ID Patient Name Study UID Image Count kkkname 1 2 826 0 1 3680043 6 1 192 168 0 11 3 KOCHIYA MADHA 1 3 12 2 1107 5 1 4 5487 192 168 0 11 MJEEYARATHINA 1 2 840 113619 2 55 1 1 192 168 0 11 Mr KRISHNAN 45 1 2 392 200036 9123 100 192 168 0 11 NEELA MEGHA M 1 2 840 113619 2 22 288 192 168 0 11 RSNA06_D54A009 NICOLAS NECK 1 2 528 1 1003 5 3 99 20 192 168 0 11 oooid oooname 1 2 826 0 1 3680043 6 3 192 168 0 11 Use the Move UP and Move Down buttons to increase or decrease the process priority of the selected study Clicking on the Pause button will pause the download process Click on the Hide button to hide the Download Window Right clicking the Study list Area of the Archival Screen and selecting View Downloads helps you to view the download window Note Right clicking and choosing View Downloads displays list of all the download process in progress 3 10 Export Selected Study Series to Disk Right clicking the desired study series and selecting Export Selected Study Series to Disk option exports the selected study series to the target drive Right clicking a study and choosing Export grid data to file option exports the selected data as an html xml Excel T ext file to the chosen destination 3 11 Delete studies You can delete a study multiple studies from the local archive by selecting the studies in the study data grid and
42. 310 471 8900 giesberg digitalams com To include center information click on the Center Information Tab If the letterhead is to be included in the Report select the Use Letterhead check box and enter the top margin value Notes The top margin value indicates the space between the top of the page and the patient information grid The top margin value is in pixels not in cm or inches If a logo is to be included in the report then click on the E and choose the necessary file Otherwise type in the required details You can change the format of the text such as font indent position alignment etc in the Reporting Region using the formatting toolbar Note 1 Pressing the Enter key in the keyboard will result in double line spacing between the text lines Use Shift Enter keys in the keyboard for single line spacing between the text lines 2 The font size available in the Report Master does not correspond to other window applications Here 1 8 pt 2 10 pt 3 12 pt 4 14 pt 5 18 pt 6 24 pt 7 36 pt To include the Patient information click the Patient Information button in the Report Header Designer Dialog and type the required details Then place the cursor in the required location of the Report Header area select the required fields from the Field drop down list and click on the Add button Say for example if you like to include the Patient ID in the Patient Information Grid of the Report click at the positi
43. 4 AP 12 16 12 35 CT 1 1 101 9 KE 3 8 Merge Series The merge series feature of the CATELLA PACS 5 0 Viewer Application helps you to merge two series of the selected study into a single series To do this select the study and right click the Series Display Frame of the Archival Screen and select Merge Series ESS sn ARCHIVE IMAGE VIEWER PRINT COMPOSER Co WRITER IMAGE ACOSTA Paves fF nex sey nob nce sds ec Jage mage j DRSC HITAN A Tees CT 13 4 AB 3377 OHEST 3377 Fr Open Study INTA 12255 2 OT it 12 16135 ADIGE 122355 Merge Series Write to CD DVD Write ta CD elect Remote Hode 1 2 AP Acquire Image Custom Search Export selected series to disk MB A Merge Series Dialog with all the available series for the selected study opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 19 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ai Exam Details Patient ID DR S K RAJAN Patient Name NIZAMUDEEN D A MR Modality Study Desc CHEST Study Date 12 16 2004 Images Count Series List Key Series Series Series Descr Series No 1 Series Desc AP Scout He 10 mm 1 5 127 16 12 30 Series Date 12 16 2004 Series UID 1 2 840 113619 Series Time 12 30 1895 Modality cT Merge Series Series Series Descr Series
44. 6 2 5 1 1 1 2 392 200036 9116 2 5 1 1 1 2 392 200036 9116 2 5 1 1 7 4 Query from Modality Worklist Server 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 52 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Ai This section explains the procedure of retrieving study details from the Modality Worklist Server based on one of the search criteria like name ID sex scheduled date accession number and modality To query from the Modality Worklist Server Click Worklist Button and a Worklist Screen opens Enter any or a combination of the search criteria and click Query button The nearest match retrieved from the Modality Worklist Server will be displayed as shown in the figure below DICOM Worklist Name ID Sex Scheduled Date Modality Accession Query stream 7 i0 Accession nos Modality Study UID Study Date prasad Reddy sai 123456 M 1 2 826 0 1 Swinflu 9 8 2009 krishna gopal 54564 M 1 2 826 0 1 abdomen 10 1 2009 rao hanumant 546 CR M 1 2 826 0 1 obesity Load To load any saved worklist details Save To save queried worklist details 7 5 Import Non DICOM Image Files This functionality enables you to import JPEG BMP AVI image files from any desired location to the current patient record To import Non DICOM image files 1 Click eee Look in ji sidhu J Ge ie Name Date taken Tags Size Rating ay Ji New F
45. 8 C Program 30092009 1 1 9 C Program 30092009 1 1 4 10 C Program 30092009 1 1 11 C Program 30092009 1 1 C Program 30092009 1 1 0 Now select the images that you wish to include in the new series from the Current Series Image List Frame Note Use the Ctrl Key in the keyboard to choose multiple series Click To Move the chosen images from current series image list frame to new series image list frame Move all the images from current series image list frame to new series image list frame 4 Move back the chosen images from new series image list frame to current series image list frame lt 4 Move back all the images from new series image list frame to current series image list frame Finally click on the Split button You will find a new series including selected images being displayed on the Archival Screen as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 18 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ARCHIVE IMAGE VIEWER PRINT COMPOSER CD WRITER IMAGE ACQUISITION Drag a column header here to group by that column MEI 3 Study Institution Departme Performin Reading P Referral F Operator E DR S K NIZAMU M 12 16 CT 5377 CHEST 5377 049Y 13 Series Series MOD Series Image Series 1 2 82 He 10 12 16 12 35 CT 3 4 2 0 MB 6 4 MB 1 2 84 He 10 12 16 12 35 CT 2 8 4 0 MB 1 2 8
46. A PACS 5 0 Viewer Application Then select the appropriate image that you would like to review and click on the button You will notice that the dark fluid image corresponding to the selected normal image being displayed on the image review window Note Choose the image series layout as 2x2 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 43 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 5 Print Composer CATELLA PACS 5 0 Viewer offers you the functionality to print all the selected images in the desired print layout using a DICOM printer 5 1 Print Composer Overview To print the selected images Click on the Print Composer tab in the main screen The images of the selected study that you have added using the Send to Print Composer option in the Image Review Screen will appear on the Print Composer Window in the default print layout as shown below iD COCELLA DACS i PRINT COMPOSER VoF ETRE er ee sat arvor detee CE S E B E ma i e s E m E E E Page Layout Select the print layout that indicates how many images to print on a single sheet For example selecting the I option allows you to print two images on one sheet of paper You can also design your own print layout by selecting the required number of rows and columns using the Rows Columns Option Right clicking and selecting Split Vertically Horizontally from Popup can split the selec
47. AGE VIEWER Gaiiuieeiiejag Kerhad Elite a lee Bie DESSS8 OOOO deacons E GH O80 S08s SGESo0n ba ay 12 16 2008 be 1 me 1 5 Preferences Hep P a Images 2 9 x C49 NIZAMU ULE MUA MIR Overlays Presets Processing Mode Display Delete all annotations Reset Level and orientation F2 Select all images Ctr A Delete Presentation state Customize hot keys Send to remote node Send to composer F5 Quick print Export images to powerpoint Create AVI file from series Image Attributes Save Hanging Protocol N Save As Hanging Protocol List Mark as key image Configure Window Delete Current Protocol D eimi Ml ogdgga Select the Image Series Layout for the Image Review Window Then drag and drop the required image series into the desired layout and right click and choose Hanging Protocol gt Configure Window as shown in the above diagram A Configure Hanging Protocol Dialog as shown below opens Study description Body part Series description __ Prior Window Level Rows Columns Invert CT CHEST Abdomen He 10 mm 1 5 Cancel Select the Modality and enter study description Select the Body Part for which the hanging protocol is applicable to and then enter the series description case sensitive of the required series Note Modality Study Description and Body part Series Description are mandator
48. COMDIR Button An Open Dialog as shown below will be displayed Select the storage location and click OK Button Browse for Folde em Select output directory MB Desktop ae Network gt Gl Sangeetha gt J Public a Ml Computer p Local Disk C gt a Local Disk D gt g Local Disk E b g Local Disk F gt CA DVD RW Drive G Sangeeeeeceeceecee gt a Removable Disk H 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 68 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 8 Preference Settings Once CATELLA PACS 5 0 Viewer is registered you have to carry out various functionality settings before you work with CATELLA PACS 5 0 Viewer application This chapter describes each of the settings in detail The administrator has the privilege to customize these settings for different users of the application Please note only the administrator has the rights to customize the settings for other users If you login into the application as administrator select the user for whom the settings have to be made 8 1 Administrator Settings Only the administrator has the right to access this functionality This feature of the software helps you to carry out DICOM server settings Data Backup Settings and Storage Management Settings It also helps to set Router Rules and to add and delete new users of the software To access this functionality click on the Administrator Tab in the Setting
49. D Technologies Inc Doc 340 3 503 Rev 01 Page 89 CEE A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual _____ ee The table below gives a quick overview of the fields in the Search Filter dialog Fieds Ci escriptions _ ___ _ Enumerates the filter description Patient Name Specify Patient Name Note To get the details of all patients leave the field blank or type in the field Patient ID Specify patient ID Note To get the details of all patients leave the field blank or type in the field Specify patient s sex Modalit Enumerates modality name Study date span Select study date span as today yesterday last week or last month Query Type Select the default query source for the Filter Note All the DICOM nodes with C Find and C Get C Move option enabled that you have added using the DICOM Server Settings will be listed here To edit Filter settings 1 Select the Filter to be deleted from the displayed list 2 Click ajja button in the Filter Settings Dialog 3 A Search Filter Dialog opens Make the necessary changes and click on the OK Button The Filter name is restricted from editing To delete Filter settings 1 Select the Filter to be deleted from the displayed list 2 Click on the button in the Filter Settings Dialog 3 A Confirm Dialog opens Click on the OK Button to continue 8 6 CD DVD Distribution Settings This feature helps you
50. E AE A EE E A A E A A 58 7 9 Annotation ScreeM sroine ne eee nen men iai ea nt one Tom er ESEE EEA EEE EEE EEE n ee eee ne ee EEEE cree ianiai 59 7 9 1 How to mark annotations on the image sccsaccsancxasesecenesindacnecstenaunsnndiapeedssveevendideiasaeussn nase ddadnadediGoaastadannacedageesntscnmaanidiaecancddns 60 D2 a S E E E sine este A E A E A V E E soc E A A E AEE E T A cocina 62 Pome E E E E E S 63 729 4 nVen Rotae ana FP IMAO erisa E Ea EE ONEEN Era ai 64 TOA a Cusomzed RoaUon S SUNOS eseis aar E E ERE EREN 65 FD Wee Resizo Resample IMAHE sersssseds orn sereia a AT aaersdad aca encana ss endaaceneneabacanueaseuees 65 TE EPEL i E E N EA A E EN E et oe E AEE N E een A E E V T E AAN ee E A E 67 TOA Delete FUG LAM OINS seissen a AT AE EEEE ER AR 67 7 10 Save selected image to disk output directory x sectss scnececemacecesdnsesccexaaneideedsannnecenassesivansencesanns selena nseasanePeudesssercctsnedeeledssnecanacevenbes 67 7 11 Write DICOMDIR for a selected IMAGG Acxcasssaccesnscnvssanseaceenaddannescncusasaandennedddeanseendianessosmabnnad isa RARE RROA TAAA RERAN A ANKE REKAAN TARRAA 68 8 1 Administrator Seting cyanea nee ee mete ee api aea AAN A REAA OS E ee eee rere 69 EDIC ON Er e 11 ge e E E E A E E eee nee eee eee 69 8 1 1 a Add Edit Delete DICOM Node ccccccccccccceeeeee eee e eee e eee e eee ee eee eee e eee e eee eee EE EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEES 70 8 1 1 b How to Add Edit Delete DICOM
51. He 10 mm 1 5 12 16 12 30 CT b Choose the key series with which you wish to merge the other series of the study from the Series List Frame Then select the series that you want to merge with key series from the Series List Frame and click the Merge button Note use the Ctrl key in the keyboard to choose multiple series You will notice that a new series including both the key series and the merge series being displayed in the Archival Screen as shown below ARCHIVE IMAGE VIEWER J PRINT COMPOSER J CD WRITER IMAGE ACQUISITION sn Drag a column header here to group by that column Patient Fit nfsex Study MOD acces study Stuy age image Study nstiztorDepartme Performin Reading Referral Operator 6 4 MB Load Files DICOM Directory Open Study E DR S K NIZAMU M 12 167 CT 5377 CHEST 5377 049Y 13 elect Remote Node Search Custom Search 3 9 Download Studies This option of the CATELLA PACS 5 0 Viewer helps you to download all the images corresponding to the selected studies in advance thereby reducing the time taken to load the images during the image review process To do this select the studies whose image you wish to download from the Archival Screen and right click and choose Download from the Pop up A Downloads Dialog opens as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 20 a A D AMD Technologies Inc Catella 5
52. Label for Single Study Job Multiple Study Job and Anonymized Job Note When the job spans more than a disc the job will be written onto multiple discs depending on how you have chosen to split the job based on the study series or image level CD Label Settings Next to add edit delete a CD Label file click the Define Labels button in the Distribution Dialog which pops up a Media CD Labels Dialog Media CD Labels Label File List Filename C Users Sangeetha Desktop s Feld List ms C as a General The Default CD Label will be displayed in the Label File List Double clicking the Default Label name enables you to edit the CD Label in the CD Designer Application To add a new CD Label File 1 Click the Add button A Label File dialog opens as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 92 ee A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee Label File Description Label 1 Filename C Users Sangeetha Desktop sangi c btw 2 Specify the Description of the CD Label file Then click Ej button and locate the CD Label file using the Open Dialog Note The CD Label file has a file extension of btw The CD Label File has to be designed using a CD Designer Application that comes with the RIMAGE Installer 3 Then select General and click the Add button in the Fields List Panel of the Media CD Labels dialog A Media Label dialog opens Ca
53. MD Technologies Inc Doc 340 3 503 Rev 01 Page 106 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 9 Report Designer The chapter gives you a detailed description on how to design a Report Header and Report Templates for various studies and how to prepare a report for the selected study 9 1 Categorize Report Templates This option of the CATELLA PACS 5 0 Viewer Application helps you to categorize the report templates To do this Click on the button in the CATELLA PACS 5 0 Viewer Screen and choose the Reporting Tab in the Application Settings dialog An Application Setting Dialog displaying all the predefined report templates opens Application Settings F Template Name MRI CERVICAL SPINE CERVICAL SPINE ABDOMEN SHOULDER Abdomen Male Early Pregnancy tst tmp 4 def Header Designer Category List Now to add a new report template category click on the Category List button in the Application Settings dialog A Category List Dialog as shown below opens ma Category List i Category Name General 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 107 Ai AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Click on the Add button in the Category List Dialog and enter the category name in the dialog shown below To edit the category name select the required name from the Category List Dialog and make the required changes in the catego
54. Patent s Name tst 5 Create New Template Edit Template Description Patient ID Patients Age Patients Name Window Width amp Level Click this to edit selected template name eat bet Patient 7 l Patient iD Sample Text 8 4 Annotation Settings This functionality enables you to set the properties of the annotation options like line arrow rectangle ellipse or circle and the text marked on the image On clicking the Annotation tab in the CATELLA PACS 5 0 Viewer Application Settings Dialog an Annotation Settings Dialog opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 87 EN A D AMD Technologies Inc __ _ Application Settings Change Preference Password Select User Admin Catella 5 0 PACS Viewer User Manual Line Settings Line Color Line Width Line Style solid Line gt Fill Settings Transparent Fill Color Fill Style Solid a Administrator General Modality Annotations Filters Reporting Distribution Acquisition Font Settings Measurement Font The primary elements of the Annotation Settings Dialog are listed below Fields Descriptions S O To select the default color of the line drawn on the image Line Width To select default width of line drawn on the image Range should be from 1 to 5 units Line S
55. TELLA PACS 5 0 VIEWER backup service Import predefined configuration settings to the application 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 75 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual A Export the current configuration Export Configuration Settings settings of the application Backup the application database Schedule the backup process Create a backup copy of your Backup and Restore database PAE a configuration data and helps you to restore them in the event of a hardware failure or accidental erasure Note The Backed up with delete studies will be displayed in red color in the study data grid and on double clicking the details of the stored volume will be displayed 8 1 5 a Import Configuration Settings For importing the configuration settings Click the Import Configuration settings button and choose the xml file containing the Configuration settings and select the desired settings and click Import button and click Yes button in the following message box The application will be closed and the imported settings will be applied on restarting the application 8 1 5 b Export Configuration Settings For exporting the configuration settings of the CATELLA PACS 5 0 Viewer Application click on the Export Configuration Settings button which will be followed by a dialog shown below Select the appropriate configuration settings that you wish to export and click o
56. Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee Chapter 1 Introduction CATELLA PACS 5 0 Viewer is the DICOM viewing Application and processing tool for Radiologists It can be easily configured in a PACS environment and also used to access studies from a remote location It has a wide range of visualization measurement study display and distribution features with an easy to use user interface It converts secondary captured non DICOM images into DICOM images and has the functionality to associate the scanned images or reports with the patient study data 1 1 Features User friendly Quick retrieval of Study Details Query Study Details from a local remote DICOM Server based on customizable filters Electronic distribution of patient records Prevent unauthorized access of patient records Carry out linear area and angular measurements easily Capture Single Frame AVI Cine Loop using a Standard Non Standard card amp send the images to a DICOM Server as a DICOM file or save it as DICOM images or DICOM DIR Import DICOM JPEG BMP AVI files e Supports Modality Worklist Server and DICOM Query Retrieve Patient Information e Support TWAIN based scanner for scanning old reports and images and convert them as DICOM images 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 5 SSS A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual _ ee Chapter 2 Getting Started This chapter gives you a general
57. ails anonymous in the DICOM images Refer to preferences for anonymize settings Click Delete button to remove the unwanted images from the job Once you have selected the appropriate studies click on the Write to CD button in the Job Details Dialog in the CD Writer Screen CD WRITER Then click on the CD WRITER button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 48 a A D AMD Technologies Inc ____ Catella 5 0 PACS Viewer User Manual A CD writer window appears displaying jobs of all status Such as queued completed deleted etc as shown below OMB 750 MB 1500 MB Select Drive G 2 0 0 HL DT ST DVDRAM GH22NSS0 TNOO v Job Status COMMENTS D amp Queued Queued Patient DR P V SUNDARAM 69 M Queued Patient DR P V SUNDARAM 69 M Queued Patient DR P V SUNDARAM 69 M Queued Patient NEELAMEGHAM Queued Patient UnKnown Queued Patient Priscilla Queued Patient NIZAMUDEEN D A MR 2250 MB Volume Label CREATED Admin Admin Admin Admin Admin Admin Peale GUNS ENE CD WRITER IMAGE ACQUISITION DVD R 3000 MB 3750 MB pans Write CO BY COPIES IMGs SIZE ANONYMIZE BURN VIEWER Create 1 61 8 3 MB 7 10 2 1 61 8 3 MB 710 21 4 20 27MB 7 10 21 1 312 156 5 MB 7 40 21 1 0 Obytes 8 27 21 4 4 291 1MB 9 17 21 1 113 6 4MB 9 30 21 Preferences If you were set up to use the local CD DVD burner for writing the studies onto the CD DVD select the Drive
58. alog Next click on the Properties button in the Interface Dialog and set the required film scanner property Refer Set Film Scanner Property for setting the film scanner properties Once you have set the properties click on the Start Scan button to start and the scanning operation and then click on the Stop Scan button to stop once required portion of the film is scanned 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 58 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ss You will notice that the scanned images will appear in the Interface Dialog as shown below You can double click the on the image and do the annotations like Window leveling Pan zoom and rotate the image using the annotation tool buttons like in the image viewer Click on the OK button to load the images current study iA AiD VIDAR Interface 7 9 Annotation Screen This section describes the annotation tools available in the Image Acquisition Screen Double clicking the imported captured scanned image displays the annotation tools in the Image Acquisition Screen ey 21Jun95 Tis 1 5 MIOS rar iia INCOR S P BRASIL MPT7 4 TEE 12 20 57 pm 35 Hz 12 0cm Clear All Map 3 DynRg 50dB Persist Low Fr Rate Med a MITRAL VALVE VEGETATIONS l 112 ee ee ee RPM 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 59 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T
59. cic 1 112 Lumbar L1 L7 Socral S1 S5 Select the label you wish to atart Labels with in any series and then click on the point you wish labeled The next click will place the next sequential label on the film For example select S2 for the first label and the next label will be S3 Copying and Moving Annotations To copy an annotation click on the annotation press Control C to copy To move an annotation click on the annotation move the pointer to the new location and then press Control V to move Please note You can place the annotation toolbar at any required position top bottom right or left of the Image Review window To add or remove the buttons from the annotation toolbar click on this and select Add or Remove buttons Then select the appropriate buttons that you would like to include or remove from the Annotation Toolbar You can customize the annotation toolbar for any specific study using the Modality Settings Option Please refer to Modality Settings for details 4 1 1 Deselect an Annotation Tool To deselect the selected annotation tool or to activate the mouse pointer Click button Or Right click on the Image Review Region and select Mode gt Select Or Press the Esc Key in the keyboard 4 1 2 Zoom and Pan Image To zoom and pan the whole image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 25 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Click button Or
60. e st Toolbars Commands Options Personalized Menus and Toolbars jw Show full menus after a short delay Reset my usage data Other Large icons Wo Show Toollips on toolbars W Show shortcut keys in ToolTips Menu animations None To show only basic and frequently used commands on the toolbar select the Menus show recently used commands first check box Clear the Menus show recently used commands first check box to show all the commands on the toolbar To show all the menu commands on the toolbar after a delay select the Show full menus after a short delay check box Clicking the Reset my usage data button resets the toolbar buttons shown on the built in toolbar if it is not wide enough to display all the buttons Checking the Large Icon checkbox increases the size of the toolbar so that it is easier to view Displays on screen descriptions of toolbar button when the pointer pauses on them when Show Tooltips on Toolbar checkbox is checked 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 85 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual To show keyboard shortcuts in the tooltips check the Show shortcut keys in the Tooltip Menu Animation changes the way menus display when you click on a button 8 3 3 Define Overlays This feature of the CATELLA PACS 5 0 Viewer helps you to define overlay templates for a Define Overlay List selected Modality To do this select the Modality a
61. ed files to Checking this will add all the DCIOM files thatyou imported archive to CATELLA PACS 5 0 Viewer s local Database Retain hounsfield labels l S l on mouseup Selecting this will display the hounsfield labels on the image Auto Log off interval Automatically logs off the application window when the application is ideal for n minutes you specify here 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 78 Display Thumbnails lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Sae Once you have selected deselected the appropriate options click on this button to save the settings To change the password of the currently logged in user Change Password Click the jn the General Settings dialog A Change Password Dialog as shown below will open Change password Old password New password Confirm password Now if you wish to change the old password enter the old password and the new password with confirmation Then click the OK button If you want to remove existing password don t want the password option to appear while opening the software type the current password in old password edit box and leave the new password and confirm password edit box blank And then click OK button Please note the password field is case sensitive 8 2 1 Customize Hot Keys This option helps you to customize the keyboard shortcuts for various functions of the CATELLA PACS 5 0 Viewer application
62. elect the image and press Delete Key in the keyboard Or Select the image and click n button Merge AVI T his option allows you to create an avi file from single frame images To merge multiple single frame images select the images and right click the Import Screen and then click Merge option from the Pop Up As a result of this operation the single frame images will be removed and an AVI file will be created from the selected single frame images Note Only the images having the same width and size can be merged 7 6 Capture Live Video Single Frame Image This functionality allows you to capture a live video or a single frame image using the video capture card On clicking CAPTURE button in the Import Screen a Video Capture Screen will appear as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 54 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual CSS COREE GE CE wace acquismon GERACE ao Patient Details DAVID RAJU 78 Y M Bn NF o CAPTURE FRAME a AE THUMBNAILS a STOP CAPTURE The fields in the Video Capture Screen and their descriptions are listed below Buttons Click To CAPTURE FRAME START CAPTURE To capture a single frame image Start cine loop or multiframe image capture Stop cine loop or multiframe image capture RETURN TO THUMBNAILS Return to thumbnail view Single Frame Image Capture To capture the single frame i
63. ert Reset Toolbar Customize 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 83 ease A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee To customize the toolbars select Add or Remove Buttons gt Customize A Customize Dialog opens listing the available toolbars To display a toolbar select the check box next to the name To hide a toolbar clear the check box W Annotate W Measure Button Click To New Create a new toolbar Change the name of the selected toolbar Remove the selected custom toolbar R Removes any changes you have made to the selected eset as toolbar and restores the original settings To create a custom toolbar Click on the New button An Add Toolbar Dialog opens In the Toolbar name box type the name you want and click the OK button Add Toolbar Toolbar name cance To add a button to the toolbar click the Commands tab in the Customize Dialog In the Categories box click a category and drag the command you want from the Commands box to the toolbar 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 84 ae A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual AD Customize Toolbars Commands Options Categories Commands Select Pan Zoom Il Rotate Left Rotate Right Flip Horz Flip Vert Description Switch between personalized menus and built in menus Click on the Options tab AiDCustomiz
64. he number of pixels in the image vertical axis with a particular brightness value horizontal axis To access this feature click on this ae button in the Image Review Screen of the software You would notice an image histogram dialog displaying the histogram of the selected image being displayed on your screen Image Histogram ij ij kJ in a ke mse mm o a co e rm om Patient NIZAMUDEEN D A MR DR S K RAJAN Study CHEST 12 16 2004 4 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000 9 000 10 000 Bins a To change the intervals of the X and Y axis move the Bin Size Slide bar to the right or left accordingly Selecting the 3D Check box will display the 3D view of the histogram Checking the Display Title check box will display the patient details including name age sex and ID and study details You can also copy the histogram as a bitmap or other type of image using the Copy Button Click on the Export button in case you wish to export the histogram to any specific folder or path An Open dialog pops up on your screen Choose the destination folder and click on the OK button Clicking on the Print button will print the histogram using the default printer configured on your machine Apply Window Level Presets This feature of the CATELLA PACS 5 0 Viewer Application helps you to apply predefined Window level presets to the selected image To do this 2010 AMD Technologies Inc
65. he source study from the Destination Study Frame and click on the Merge button Note Use the ctrl key in the keyboard to choose multiple studies gts a F RU aS Sl cg fa Source Study Patient ID DR S K RAJAN Patient Name NIZAMUDEEN D A MR Modality Study Desc Study Date 12 16 2004 Images Count 12 Destination Study Modality S Desc S Date Accession No Images Image Size S UID aa ee ee RETS 411546 TEBE Merge acces 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 16 ZD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual You would notice that a new study including the source study and the destination studies attributes being displayed on your screen as shown below RGN EE Cee Cs Ce BE Drag a column header here to group by that column Load Files DICOM Directory 2 Patient l First N Sex Study MOD Acces Study Study Age Image Study Institution Departme Performin Reading P Referral F Operator gt DR S K NIZAMU M 12 16 CT 5377 CHEST 5377 O49Y 13 6 4 MB belect Remote Node 3 7 Split Series The split series option of the Viewer Application helps you to split an image series of the selected study into two To do this select the desired study from the Archival Screen and choose a series that you wish to split from the Series list frame of the Archival screen Then right click and select Split Series
66. his option will automatically capture the images at the specified interval 8 7 5 Footswitch Settings Fields _ Descriptions To enable disable RTS To enable disable RTS S DTR Enable To enable disable DTR Polling Frequency Specify the time delay between the 1st and 2nd press of the footswitch 8 8 5 How to set Password for Preference Screen The set password functionality for the preference screen is an optional feature For security reasons you can set the password for the same 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 105 a A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee To set the login password for preference screen click Password button and a Password Dialog will be displayed as shown below Change password Old password Confirm password When you are setting the password for the first time leave the Old Password box blank and enter the new password with confirmation And then click on the Save button Now if you wish to change the old password enter the old password and the new password with confirmation Then click the Save button If you want to remove existing password don t want the password option to appear while opening the software type the current password in old password edit box and leave the new password and confirm password edit box blank And then click Save button Please note the password field is case sensitive 2010 A
67. how through the background color of the annotation ellipse rectangle and text box select the Fill Style option in the Set Properties dialog as Clear Refer setting the default properties of the line arrow rectangle and ellipse drawn on the image 4 1 8 Include text on the image To include text on the image 1 Click T button Or Right click the Image Review Region and select Mode gt Text option from the Pop Up Or Click the T key in the keyboard 2 Left click and drag the mouse from the desired point of start and end to define a text box of the desired size You can move the text box to a desired position with the mouse if necessary or you can change the size of the text box using one of grab tabs around the edge Type the text in the text box and click the Enter Key or click the mouse pointer anywhere outside the text box 3 You will notice that the text will appear in the default font settings To change the font settings of the text and the location and size of the text box double click on the text box Refer preferences to change the default font settings of the text tool 4 A Properties dialog as shown below will open Specify the new location and size of the text box 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 29 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Then click the Set Font Tab in the Properties dialog which will be followed b
68. ick button or double click the image in the Annotation Screen 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 61 TEREN l A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual P Note You can move the selected annotation with the mouse or you can change the size of the annotation using the grab tabs around its edge if necessary 7 9 2 Properties This option is used to set the properties of annotations like line arrow square circle polygon and text marked on the image To set the properties 1 Select the annotation and right click the image and select the Properties options from the Pop Up as shown below Annotate Mode b b Process b Zoom Delete Delete All Set Properties Line Settings Line Color Sa Line wieth 1 3 3 Change the required parameters like line colors line width line style fill color and fill style To change the font size of the text in the image use the Set Font option Click the OK button to save the settings 4 Notes To allow images to show through the background color of the annotation circle ellipse rectangle square and text box select the Fill Style option in the Set Properties dialog as Clear 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 62 A AMD Technologies Inc Catella 5 0 PACS Viewer User Manual 7 9 3 Image Cropping This option allows you to retain the desired area of the image by discarding the image region lying
69. ient Name Value PatientName Note General Text in the Fields List Panel represents the First Study 4 Inthe Caption Edit box enter the merge field name say for example Patient Name that you have specified in the CD label file Select the corresponding value and click OK button This enables the application to print the value corresponding to the specified Merge Field Name onto the CD 5 Repeat 3rd and 4th steps to assign a value to all the required merge fields in the CD Label File for a single study 6 To include multiple study details click button in the CD Labels dialog A Label dialog pops up Enter the merge field name say for example Patient Name that you have specified in the CD label file in the Caption Edit box Select the corresponding value and click OK button Caption Patient Name Value fPatientName hi 7 To add other merge fields select the Study1 label in the Fields List Panel in the Media CD Labels dialog and repeat the 3rd and 4th steps 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 97 eens l A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Media CD Labels Label File List Label Name Filename C Users Sangeetha Desktop s Patient Sex PatientSex Study 1 Patient Name PatientName Patient ID Patientid 8 To edit the merge field names and its value select the merge field name and click Edit button in
70. ings Institution Name AMD TECHNOLOGIES Institution Address 218 BRONWOOD LOS ANGELES CA Referral Physician DICOM Settings DICOM Query Server ATLSRVR 7 Filter Worklist for AET DICOM Worklist Server ATLSRVR X Force to Grayscale Preferred Transfer Syntax Implicit VR Little endiz Video Capture C Use non standard capture Auto Capture Device v Format I interval 1 s Compressor Microsoft MPEG 2 Video Encoder z B Footswitch Settings Activate Footswitch Comm Port DTR Enable _ Polling Freq ms RTS Enable Scanner Settings Default source TT 8 7 1 Default Institution Settings Fields Descriptions _ _ _ 8 7 2 How to Referral Physician To add a default Referral Physician click es A List of Referring Physicians dialog as shown below will be displayed List of referring physicians 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 104 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee To add a referral physician specify the physician s name in Physician Name edit box and click Add button To delete the desired Referral Physician select the physician s name from the displayed list of referring physicians and click Delete Button To update change Referral Physician name select the physician s name from the displayed list Make the necessary changes in the Name edit box a
71. ion and select Processing gt Flip Horizontally option from the Pop Up Or Click shift lt keys in the keyboard Click Or Right click the Image Review Region and select Processing gt Flip Vertically from the Pop Up Or Flip Image Vertically 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 26 Bees A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T Po Click shift gt keys in the keyboard Click E button Invert the RGB value of Or the image or view the Right click the Image Review Region and select negatives of the image Processing gt Invert Image from the Pop Up Or Click I key in the keyboard 4 1 4 Reset Level and Orientation of image This option is used to reset the level and orientation of the image after zooming rotating or flipping the image To reset the image ey sa Click on button or right click the image and select Reset Level and Orientation option or press the F2 Key in the keyboard 4 1 5 Change Window width and level To change the window width and level 1 Click button Or Right click the Image Review Region and select Mode gt Window Level option from the Pop Up Or Click the v key in the keyboard 2 Left click and drag the mouse pointer over the image The current window width and level will be displayed at the bottom right of the Image Review Region The window leveling will be applied to all the images in the page
72. ition LOCAL CD BURNER OF PRIMERA Host LOCALHOST Server ID PS01 Client ID comite Shared Folder an Media 7 cp 650 MB 74 mins Covo O use pvo if if size gt CD capaci If job spans multiple discs split job at Study Level Default label for single study job Default label for multiple study job Default label for anonymized job Define Labels D O e amp 2cr Service is stopped Anonymization List Job Filter Settings 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 91 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee The Server ID PS01 the default Port Number 2506 default Client ID and RIMAGE UNC folder i e the shared folder created by the RIMAGE Installer will be displayed in the appropriate edit boxes Note The default values can be changed as per the requirement but the changes needs to be updated in the RIMAGE Application Then enter the CD Title Select the available storage media either as CD or DVD Enabling Use DVD if jobsize exceeds CD capacity option helps you to write the selected job onto a DVD if the job size exceeds the CD capacity Note This option is enabled only when you select the Available Media as DVD Select the Job Split Level either as a study level or a series level or an image level Then select the default CD
73. k on the OK Button button in the Modality Settings Dialog The Preset Name is restricted from editing To delete Window level presets 1 Select the modality and then select preset to be deleted from the displayed list of preset names Sones f l 3 A Confirm Dialog opens Click on the OK Button to continue 4 8 3 2 Customize Annotation Toolbar button in the Modality Settings Dialog This feature of the CATELLA PACS Application helps you to customize which includes adding or removing the required tools in the image review window the annotation toolbar for each of the modalities like CT MR etc To access this functionality 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 82 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Select the modality for which you wish to customize the toolbar Then click on the button in the Modality Settings Dialog You will notice that a Toolbar Customization Dialog pops up on your screen as shown below o E E _ _ a E E Toolbar Customization ER gt To add remove a button to any toolbar click on the arrow in the left corner of the toolbar click Add or Remove Buttons and then select deselect the check box next to the button you want to add remove Toolbar Customization ER eee Add or Remove Buttons TS g La Select i Pan Zoom j Rotate Left v v v v li Rotate Right v Flip Horz v OW Flip V
74. le on the it image 9 1 Click button Ofr Right click the Image Review Region and select Mode gt Rectangle from the Pop Up Or Press the R key in the keyboard 2 Left click and drag the mouse to define a rectangle Draw a circle or ellipse on Oo the image 9 1 Click button Or Right click the Image Review Region and select Mode gt Ellipse from the Pop Up Or Press the E key in the keyboard 2 Left click and drag the mouse to define a circle or ellipse Draw a freehand line or shape f P 1 Click button 2 Left click and drag the mouse to define a freehand shape All the annotations line arrow circle and rectangle will appear in default line and fill settings To change the default line and fill settings and to change the location and size of the image double click the annotation A Properties Dialog as shown below will open 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 28 e A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ___ ee Location and Size j Left 4 Top 324 width 110 Height 84 Line Settings Line Color re Line Width EE Line Style Solid Line gt Fill Settings Transparent C Specify the new location and size of the annotation Then change the required parameters like line color line width line style fill color and fill style Click on the OK button to save the settings Notes To allow images to s
75. lter criteria will be displayed on your screen SOE Mc Ace viewer Jf rc conroser f co warren f mace AcQUSITEN co an Load Files Drag a column header here to group by that column Patient iret Nex study moD JAcces study study Age image study institut Departme Performin ReadingP Reteral Floperator DICOM Directory eo gt 290920 hjjh sc OO5Y 1 00 3 KE Open Study ay ORLS K NIZAMU M 12 16 CT 5377 CHEST 5377 049Y 0 bytes PRECISION Write to CD View Report felect Remote Node Search Custom Search cT MR Please note the queried studies can be sorted based on any of the attributes like patient id name etc by clicking on the appropriate tab 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 10 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee 3 2 Load DICOM File If you wish to review the image corresponding to a specific study you can load that DICOM File Load Files to the CATELLA PACS 5 0 Viewer Application by clicking on the button in your CATELLA Archival Screen Next an Open Dialog pops up on your screen Locate the DICOM file that you wish to load and click on the OK button aa Open Look in J Series 2_He 10mm 1 5 Name Date modif Type Size e Pls ee __ 1 2 840 113619 2 81 290 26072 5377 2 1 2 __ 1 2 840 113619 2 81 290 26072 5377 2 2 2 a __ 1 2 840 113619 2 81 290 26072 5377 2 3 2 Desk
76. m free disk space in MB to be present in the active storage volume of your local archive And then select Delete Oldest Study Option or Delete Largest Study Option and specify the number of studies to be deleted Note If the free disk space on the active volume of your local archive becomes less than the value that you specified in the If Space Less Than Edit box the application will automatically delete n number of oldest largest studies from the local archive based on the appropriate option you selected Enable Delete logs based on log s age Option and specify the number of days after which you wish to delete the backup service log files 8 2 General Settings This functionality allows you to set various general settings like the series layout thumbnail display state of Image Viewer Window etc of CATELLA PACS 5 0 Viewer It also helps you to change the password of the current user of the software On clicking the Preference Button in the CATELLA PACS 5 0 Viewer Main Screen an Application Settings Dialog opens Then select the user for which the settings are applicable 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 77 lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ Application Settings Select User Admin Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition Series Layout
77. mage click button or click the footswitch The thumbnails of the captured image will appear Double click the image and make the necessary annotations Cineloop Multiframe Image Capture To start a cineloop or multiframe image capture click button or press the footswitch To stop a cineloop or multiframe image capture click A OP CAPTORE button or press the footswitch again The captured cineloop or multiframe image appears on the Video Capture Screen 7 7 Scan report This functionality allows you to scan old images reports pertaining to the patient and to link the scanned images reports with a certain study Clicking the a dialog similar to the one shown below Button will open 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 55 CEN A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ _ E Scanner dialog visible Scanner progress bar visible Real time image display Bultered transfer Use Auto Document Feeder DPI X 3 nabile Negotiate Parameters Acquire OK Cancel The table given below gives a quick overview of all the fields available in the dialog shown above Fields Descriptions Select the scanner type Check this box to display the scanner dialog Check this box to display the scanner progress dialog To enable real time display of scanned document To enable the auto document feeder Specify the image resolution in
78. me ID sex study date accession number and modality To query from the DICOM Server Click Query Button and a Query Retrieve Screen opens Enter any of the search criteria and click Query button The nearest match retrieved from the selected DICOM Server will be displayed in the Query Retrieve Screen as shown in the figure below Refer 95 for DICOM Server Settings DICOM Query Retrieve x Name ID Sex AIOM OF Description Modality Accession Study Date From To Institution Referring Physician C 107 1 2009 m 107 1 2009 Select Server 7 Search Local Archive Name m age sex study Date Description Accessi study Time stuyuin KER BEE LENG 21455392 10 14 2005 10 43 30 AM 1 2 840 113619 III FATIMAH BE BT THANI PUCH 0 4 4 2008 Breast 1 54 43 PM 1 2 392 200036 1 sdsdsf 210920 12 00 00 AM 1 2 826 0 1 368 CHEST LUNG TEST D 4 2 2007 12 00 00 AM 1 2 392 200036 RADHAKRISHNA A R 7 07 5310 5 14 2007 Bone Scan UNKNOWN 2 28 33PM 1 2 124 285 1 1 220920 12 00 00 AM 1 2 826 0 1 368 170620 12 00 00 AM 1 2 826 0 1 368 3 31 2008 MSCT BRAIN 1 2 392 200036 FATWA AKHBAR SIDDIQ PUCH O 4 1 2008 BRAIN amp NECK 11 27 50 AM 1 2 392 200036 71YRS RAMAKRISHNA 1101098 6 29 2006 CHEST PA 0 7 53 34 AM 1 2 840 113564 1 2 826 0 1 3680043 6 3229 7 9 2009 2 23 43 PM 1 2 392 200036 911
79. n select the appropriate zoom percentage from the Submenu as shown below Select Fit To Window option from the Submenu to fit the image to the entire window Annotate gt Mode b b Process 7 9 4 Delete Annotations To delete a specific annotation marked on the image select the annotation and right click the image and then click Delete option from the Pop Up To delete all the annotations marked on the image right click the image and then click Delete All option from the Pop Up 7 10 Save selected image to disk output directory You can save the selected image as a DICOM file in a storage disk or in a default output directory using this option To save the image Click SAVE TO DISK Button An Open Dialog as shown below will be displayed Select the storage location and click OK Button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 67 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Browse for Folder Select output directory Ri Desktop gt IY Network ks Sangeetha gt J Public a jE Computer b BL Local Disk C gt g Local Disk D gt g Local Disk E gt g Local Disk F p DVD RW Drive G Sang gt a Removable Disk H 7 11 Write DICOMDIR for a selected image This option allows you to create a DICOMDIR for a selected patient image in the default output directory or in any other desired location To write DICOMDIR for a selected image Click Write DI
80. n List by 90 Degrees Or Right click the image and select Process gt Rotate Right 90 from the Pop Up Click button and select Flip Horizontally option from the Drop Down List Or Right click the image and select Process gt Flip Horizontally from the Pop Up Flip Image Horizontally Click button and select Flip Vertically option from the Drop Down List Or Right click the image and select Process gt Flip Vertically from the Pop Up Flip Image Vertically 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 64 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Click on Si button __ ee Invert Image g Or Right click the image and select Process gt linvert from the Pop Up 7 9 4 a Customized Rotation Settings You can customize the rotation angle and preview the result of the image rotation and image flipping process using the Customize Rotation Settings option To do this 1 Click Or Right click the image select Process option from the Pop Up and then select Custom Rotate option from the Submenu 2 A Preview Dialog will appear Rotate flip the image as required and click the OK button A DPreview olx Original Result button and select Custom Rotate option from the Drop Down List Cancel Rotate SO Rotate fo EEEE EEEEEEEEEEET Flip F Horizontal M Vertical The fields in the Preview Dialog and their descriptions are listed below
81. n the ok button Export Configuration Settings Modules M Users MV Print Composer Layouts M Filters V CD Labels IM Modality Settings M Anonymize Tags i User Preferences M Volume Settings I Report Header M Storage Settings Report Templates Router Rules Dicom Devices Dicom Printers Dicom Server and Distribution Settings 8 1 5 d Housekeeping Settings Clicking on the button opens a Housekeeping Dialog as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 76 CEN A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T r Housekeeping mii M Te Housekeeping Frequency s H seconds Delete study based on Study Age Studies older than 1 H days Set to 0 to delete manually Delete studies based on free disk space on active volume If space less than MB Delete o H oldest studies C Delete o H largest studies Delete logs based on log s Age Logs older than o H days Set to 0 to delete manually Specify the housekeeping frequency i e how frequently the backup process has to be refreshed Enable Delete based on Study Age Option and specify the number of days after which the studies will be automatically deleted from the local archive To delete the studies based on the amount of free disk space available on the active volume of your local archive enable Delete Studies based on free disk on active volume option and specify the minimu
82. nd click the the Modality Settings Dialog button in An Overlay Labels Dialog opens Patient s Age Patient ID Patient s Name Create New Template Template Description Description Patient ID Patient s Age Patient s Name Window Width amp Level Patient z Patient ID 7 Sample Text Window Width amp Level O To create new overlay template Click on the Create New Template button An Overlay Template Dialog opens Enter the Template Name and choose Default Option to set this template as a default template for the selected modality Template Name cy Default Add Now to add overlay labels for the chosen template click on the a button and specify the Description of the overlay label and select the data type category and the DICOM attribute The hexa decimal equivalent of the Group Element Precision and Value corresponding to the selected DICOM Attribute will be displayed 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 86 A AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Enter the prefix and suffix that you want to include along with the value of the DICOM Attribute Use the Alignment and the Position Buttons to align and position the Overlay Label at the desired position on the DICOM image Then click on the Save button Ovni te Overlay Templates Patient s Age Patient ID Template fs
83. nd number of copies and click on the OK Button Note The Application Entity Title Hostname Port number and Film Size fields are mandatory The Default Layout Combo box will display default and user defined print layouts A c symbol indicates the user defined print layouts Once you have added a new DICOM printer click on the button to check whether the connection with that DICOM printer is successful or not To edit the DICOM Printer settings 1 Select the DICOM printer that you wish to edit from the list 2 Click on the button in the DICOM Printer Frame of the DICOM Settings Dialog 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 72 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual 3 The DICOM Printer Settings dialog opens Make the necessary changes and click on the OK Button Note The AE Title Name is restricted from editing To delete the DICOM Printer Select the DICOM printer to be deleted from the displayed list Click on the button in the DICOM Printers Frame A Confirm Dialog opens Click on the OK Button to continue 8 1 4 User Management This functionality of CATELLA PACS 5 0 Viewer helps you to add a new user for CATELLA PACS 5 0 Viewer Application and also to delete the selected user details To access this feature click the Preference button in the CATELLA PACS 5 0 Viewer Screen An Application Settings Dialog as shown below will open Click the Administrator Tab and then choose Use
84. nd then click Update Button 8 7 3 DICOM Settings Filter worklist for this AET Application Generates worklist only for the calling AET Entity Title DICOM Store Sever Select the desired DICOM Store Server DICOM Query Server Select the desired DICOM Query Server DICOM Worklist Server Select the desired DICOM Worklist Server Force to Gray Scale all this will store the images sent to the store server as gray scale Preferred Transfer Syntax Select preferred transfer syntax 8 7 4 Video Capture Settings Use non standard Capture Routine To enable non standard capture routine Note Device Name Input Standard Compression Format and Override Format fields are enabled only when the Use non standard capture routine field is deselected Device Name Select the desired capture card name Input Select the input video type such as SVideo Tuner and Composite Standard Select video input standard Note Video input Standard depends on the video output standard of the machine equipment Compression To select compression mode Note Compression affects the quality of Cine loops and also reduces the file size Microsoft MPEG 4 Videocodec Version 2 gives a better output Use the compression as per your requirement Format Select video format for the capture card Note Bigger the format the better will be the print quality Use the largest format supported by the card Recommend format 720 576 Auto Capture Enabling t
85. nding to the modality of the selected image being displayed in the right click option 4 1 11 Change Image per page To increase the number of images displayed per page Click button Right click the Image Review Region and select Display option from the Pop Up and then click the appropriate option like 1x1 in the Submenu Note Pressing the 1 2 3 keys in the keyboard will display appropriate number of images in the image review screen To decrease the number of images displayed per page Click button 4 1 12 Send the selected image to a print composer To send the selected image to a print composer 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 31 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual aaa Right click the Image Review Region and select Send to composer option from the Pop Up Or press the F5 key in the keyboard The Printer has to be configured before enabling this option 4 1 13 View DICOM Attributes To view the DICOM Attributes of the selected image Right click on the Image Review Region and select Image Attributes option from the Pop Up 2 A DICOM Attribute dialog opens as shown below Click the OK Button to continue Specific Character Set Multiple values ISO_IR 100 0008 Image Type Multiple values ORIGINAL 0016 SOP Class UID 1 2 840 10008 5 1 4 1 1 2 0018 SOP Instance UID 1 2 8640 113619 2 81 290 72 0020 Study Date 12 16 2004 0021 Series Da
86. ner Properties This option helps you to set and retrieve the film scanner properties To do this click on the Properties button in the Vidar Interface Dialog A Properties Dialog opens Average Count 7 Image Height 1020 Byte Order BO_INTEL v Image Width Bits Per Pixel 8 Scanner ID Max Film Height 25 Scanner Serial Line Time 20 Scanner Firmware Version 4 Resolution 60 v Scanner HW version Scan Stage Mode STAGE_MANUAL v Scanner RAM size Translation Table 0 v SCSI ID Dark Enhance SCSI Version Average Count Sets the line average count used for a scan Valid only for VXR 12 plus For all other film scanners this value is defaulted to 1 Byte Order Sets the byte order in 12 bit mode Valid only for VXR 12 plus film scanner 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 57 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee Bits Per Pixel Sets the bits per pixel value returned by the film scanner Maximum Film Height Sets the maximum height of a film that can be scanned in inches The maximum height of a film that can be scanned is set to a default value of 17 inches in the Control Line Time Sets the amount of time that light is collected into the film Scanner camera to determine a pixel s value Resolution Sets the
87. ng Protocol List displays the list of hanging protocols added for the study Press the Delete button to delete the chosen hanging protocol 4 1 28 Digital Subtraction Angiography DSA This option helps to apply mask for the Digital Subtraction Angiography DSA images DICOM Avi To do this right click on the DICOM Avi that you have loaded in the Image Review Window and choose DSA A DSA Dialog displaying the selected AVI opens as shown below b ook gt gt fl Apply Mask 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 42 EE A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Click To Play the DICOM avi Button _ aa View the previous frame of the avi b gt View the next frame of the avi Enable the Apply Mask Option and adjust the slide bar to get the display of the current frame subtract the selected frame in the DSA image 4 DESS mooy vas 4 1 29 Delete Presentation State Right clicking and choosing Delete Presentation State Option deletes all the annotations that you have marked on the image Note The changes are effective only when you reload the images 4 1 30 Sync Series This feature of the CATELLA PACS 5 0 Viewer Application helps you to review the normal image series and the dark fluid image series corresponding to a patient simultaneously To do this Load the desired normal image series of the selected study to the image viewer window of CATELL
88. nologies Inc Doc 340 3 503 Rev 01 Page 6 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual pene CSS CE CL CD ao Drag a column header here to group by that column Patient Il First N Sex Study MOD Acces Study Study Age Image Study Institution Departme Performin Reading P Referral F Operator Custom Search lt No data to display gt The primary elements in the main screen of the CATELLA PACS 5 0 VIEWER software and their descriptions are listed below Button _ Click To Load DICOM files to the CATELLA PACS 5 0 VIEWER Load Files 7 Load DICOMDIR to the CATELLA PACS 5 0 VIEWER Review all the Images and Reports corresponding to the selected studies Queue the selected studies for writing onto the CD DVD Write to CD Please note that this button is enabled only for the studies queried from the local archive To view the report corresponding to the selected study Please note that this button is enabled only for the studies queried from the local archive Query and Retrieve the required study details from the i oe selected DICOM Node local archive based on customizable search criteria C send to 7 i Send the selected study to the remote DICOM Node ARCHIVE Display the study details that are queried from the DICOM node or local archive Review the images for the selected study 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 7 Catella 5
89. ntrast of the image Invert the image Click button Or Right click the image in the Annotation Screen and select Annotation gt Line from the Pop Up Left click and drag the mouse to draw a line on the image Click USS button Or Right click the image and select Annotation gt Arrow from the Pop Up Left click and drag the mouse to draw an arrow on the image Click m button Or Right click the image and select Annotation gt Rectangle from the Pop Up Left click and drag the mouse to define a rectangle Click button Or Right click the image and select Annotation gt Ellipse from the Pop Up Left click and drag the mouse to define a circle or ellipse Click button Ofr Right click the image and select Annotation gt Text from the Pop Up Left click and drag the mouse to define a textbox of the desired size Type the text in the text box and click Enter Key or click the mouse anywhere outside the text box Note You can enter only a single text line 1 Click button Or Right click the image and select Mode gt Brightness from the Pop Up Left click and move the mouse pointer over the image Click Button Or Right click the image and select Mode gt Contrast from the Pop Up 2 Left click and move the mouse pointer over the image Click Eg button Or Right click the image and select Process gt lInvert from the Pop Up Return to the Previous Screen Cl
90. od specified here Click this button to run the DICOM service Clicking this button will stop the DICOM Service Click here to refresh the DICOM service y To view the operation log of the DICOM Service View Current Log DICOM node device Frame Displays the Hostname AE title Port and Description of all the remote DICOM nodes DICOM Printer Frame Displays Hostname AE title Port and Description of all DICOM printers Save Saves the settings 8 1 1 a Add Edit Delete DICOM Node To add a new DICOM Node 1 Click on button in the DICOM node Frame in the DICOM Settings Dialog 2 A DICOM Node Settings Dialog opens Dicom Node tsm Node Type Dicom Settings Alias Name CATELLA AE Title CATELLA Hostname 192 168 0 85 Port 5675 Description Supported DICOM Operations C ECHO C STORE C FIND C GET _ C MOVE Use Compression For Retrieval _ 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 70 J AMD Technologies Inc Catella 5 0 PACS Viewer User Manual 3 Specify the Application Entity AE Title Hostname Port Number and Description in the appropriate edit boxes 4 Select the DICOM operations supported by the specified DICOM Node 5 Select the Use Compression for retrieval check box to enable compression of the image during the retrieving process 6 Click on the OK Button Note Once you have added a new DICOM node click on the J bu
91. older im 30052009024 jpg m 02122008002 jpg 30052009026 jpg im 03122008011 jpg 23122008015000 jpg m 05062009028 jpg i DSCO1052 JPG 12042009004 jpg DSCO1054 JPG 14062009030 jpg DSCO1100 JPG im 14062009031 jpg m DSCO1114 JPG m 14062009032 jpg mm DSCO1116 JPG Button An Open Dialog will be displayed lt 14062009033 jpg DSC01117 JPG 16062009034 jpg DSC01159 JPG 17052009008 jpg E DSC01172 JPG 23112008010 jpg DSC01173 JPG 23122008015 jpg DSC01230 JPG 28052009019 jpg sc01231 JPG 4 File name DSC01054 JPG z Files of type JPEG Image File jpg 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 53 a A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee 2 Select File name and file type from the corresponding combo boxes and click Open Button The selected file will be displayed as shown below Double click the image and make the necessary annotations Clear All PUCH 0000003941 LUI YOONG LAI Um Mr Mo ABDOMINAL ASCITES MULTIPLE LIVER MASSES Study Details Study Date 4 2 2008 X Study Time 9 07 55 AM Accession Series Date Modality Description M ores FILM SCAN CAPTURE cs Save To Archive DESELECT ALL Save To Disk SCA ini DELETE SELECTED Write DICOMDIR Delete Image To delete the selected image right click and then select Delete option from the context menu Or s
92. on where you want the patient ID to be displayed in the Report header and then select ID from the Field Drop Down box and click the Add button Note If you want to include a special note in the Report Header area create the same in the Microsoft Word or FrontPage and copy paste it in the Report 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 110 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee Click on the OK Button 9 4 Reporting Procedure This functionality of CATELLA PACS 5 0 Viewer enables you to create a Report for the selected study using preset report templates A Reporting Screen as shown below appears on clicking the Report option in the Study Information Display Region in the Image Viewer Screen Please note that the reporting functionality is available only for the studies in the local archive z WAGE VIEWER y ae Amarse uogose ALAN Series l New Report Template Page Setup Print Save Finalize oye Psy ofeyey TETEA The reporting screen comprises fields as listed below Description Description Select the image series for which a report has to be prepared Report Layout Select a report layout type Template Select a predefined template Name Print the report Save Report To save the report Finalize Report Click this button if do not want to make further changes in the report Page setup To se
93. oses this option they skip the reporting option Increase the number of images displayed per Increase Image per page page Decca e maoe Droad Decrease the number of images displayed ge per pag per page 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 23 4 G JJ t D3 joe es A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T Previous Page View the previous page Next Page View the next page Previous Series Move to the Previous Series Next Series Move to the Next Series Export Imaaes Export the selected images to a desired P storage location Display Hide Overlays Display hide the overlays on the image Resets the level and orientation of the image after zooming rotating or flipping the image To review the normal image series and the Sync Series dark fluid image series corresponding to a patient simultaneously Multiframe Playback Options Reset Image F2 iS Play a DICOM Avi Play the DICOM AVI Pause playing Avi Pause the playing AVI Previous Frame View the previous frame of the avi Next Frame View the next frame of the avi Play all the frames of the selected series in a Play Frames loop Measurement Options Carry out linear measurements on the Linear Measurement image Find angle between two different points on Angular Measurement the image Elliptical Area Read the area
94. ous functions of the Print Composer Window 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 47 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Chapter 6 CD Writing CATELLA PACS 5 0 Viewer offers the CD DVD writing option which helps distributing the patient studies in CD DVD format with auto viewer 6 1 Write Selected Studies onto a CD DVD Select the studies that you wish to write onto the CD DVD from the list of queried or loaded studies in the Archive Screen and click on the button or select the studies and right click and say Write to CD DVD Note Only the studies queried from the local archive can be written to the CD DVD A Job Details Dialog pops up on your screen Job Details Patient ID Name Imes Size Description eer DR S K RAJAN MIZAMUDEEM DA 13 6 4 MBE CHEST no __ ae Burn Viewer Anonymize Studies _ Copies 1 Note To include more studies in the job select the required studies from the queried list and click on the Write to CD button or right click and select Write to CD DVD Enter the Comments and CD DVD Label if any Check Burn Viewer Option to burn the Auto DICOM Viewer along with study so that you can review the corresponding images using the CATELLA Viewer Note CATELLA Viewer is an application for viewing and applying various annotations onto the image Check Anonymize Studies Option to make the selected study det
95. ox The Client ID and PRIMERA UNC folder i e the shared folder created by the PRIMERA Installer will be displayed in the appropriate edit boxes Note The default values can be changed as per the requirement but the changes needs to be updated in the PRIMERA Application Application Settings Select User Admin v Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition LOCAL CD BURNER RIMAGE PRIMERA DUET Client ID CD Title Shared Folder Media cD 650 MB 74 Mins pvp O If job spans multiple discs split job at Study Level Default label for single study job Label 1 Default label for multiple study job Label 1 Default label for anonymized job Label 1 Define Labels D Service is stopped Anonymization List Job Filter Settings Then enter the CD Title Select the available storage media either as CD or DVD Enabling Use DVD if jobsize exceeds CD capacity option helps you to write the selected job onto a DVD if the job size exceeds the CD capacity Note This option is enabled only when you select the Available Media as DVD Select the Job Split Level either as a study level or a series level or an image level Then select the default CD Label for Single Study Job Multiple Study Job and Anonymized Job
96. pinous process and Transverse processes inchiding Foramina Transversormm are normal No evidence of fracture of vertebrae seen No obvious abnormal contents seen within the spinal canal Reporting Notes ay The Predefined Report Templates corresponding to the selected study will be listed in the Template combo box Select the template category and appropriate report template name The contents corresponding to the selected template will be listed in the Reporting Area Make the required changes in the report using the formatting toolbar Enter any reporting notes if any in the Reporting Notes Area Note The font size available in the Reporting Region does not correspond to other windows applications Here 1 8 pt 2 10 pt 3 12 pt 4 14 pt 5 18 pt 6 24 pt 7 36 pt Refer Design Report Template for details The image series available for the selected patient will be listed in the Series combo box Select the required series The Thumbnails corresponding to the selected series will be displayed in the Thumbnail Display Region as shown below Double click on the image to add the image to the report Click the Save button to save the report If you do not want to make further changes in the report click on the Finalize Report button 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 112
97. ption Patient Name Value fPatientName g Cancel Note General Text in the Fields List Panel of the Media CD Labels dialog represents the First Study 4 Inthe Caption Edit box enter the merge field name say for example Patient Name that you have specified in the CD label file Select the corresponding value and click OK button This enables the application to print the value corresponding to the specified Merge Field Name onto the CD 5 Repeat the 3rd and 4th steps to assign a value to all the required merge fields in the CD Label File for a single study 6 To include multiple study details click button in the Media CD Labels dialog A Label dialog pops up Enter the merge field name say for example Patient Name that you have specified in the CD label file in the Caption Edit box Select the corresponding value and click OK button Caption Patient ID Value fPatientid 7 To add other merge fields select the Study 1 label in the Fields List Panel and repeat the 3 and 4 steps 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 93 A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ Media CD Labels Label File List _ Label Name Filename C Users Sangeetha Desktop s EI Patient Sex PatientSex Study 1 z Patient Name PatientName Patient ID Patientld 8 To edit the merge field names and its value select the merge field name and
98. r Manual ____ ee This option helps you to select the list of patient study information relationship group study schedule group and patient admission tags that needs to anonymized while writing the Anonymization List In corresponding study details onto a CD or DVD For doing this click the the Application Settings Dialog An Anonymization Setup dialog opens as shown below Anonymization Setup Patient Anonymized Value v Patient s Name Anon 7 Issuer of Patient ID Patient s Birth Date Patient s Birth Time Patient s Sex Other Patient IDs Other Patient Names Patient s Birth Name Patient s Age Patient s Size Patient s Weight Patient s Address Military Rank Branch of Service Medical Record Locator Country of Residence Region of Residence Patient s Telephone Numbers Ethnic Group ws Close E ee ee Now select the required tags that need to be anonymized If you want to replace the original value of a specific tag say for example patient name with an anonymize value double click the appropriate tag An Anonymize value dialog pops up on your screen as shown below Specify the anonymize value and click OK button Anonymize Value After selecting the required tags click the Save button in the Anonymize Setup Dialog to apply the anonymize settings 8 6 6 Job Display Option Settings This option of the CATELLA PACS 5 0 Viewer Application helps to set the job filters based on
99. rch Checking this will displays the modality in the Advance Search option in Archive Screen thus helping you to query the studies corresponding to the modality using the search option Image order This combo box will appear only for CT and MR Modalities Selecting ascending or descending order the images of the opened study will be arranged in the selected order in the image viewer Define Overlay List Helps you to customize the DICOM image attributes that you would like to display on the image 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 81 lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ To add window level presets for the selected modalit Edit To edit window level presets for the selected modality Delete To delete the window level presets for the selected modality To save the settings 8 3 1 How to Add Edit Delete Presets To add Window level presets 1 Select the modality for which the preset is applicable IC 4 button in the Modality Settings Dialog 3 A Presets Dialog opens xy Window 1000 Level 50 4 Specify the Preset Name in the Name edit box 5 Specify the Window width and Level 6 Click on the OK Button To edit Window level presets 1 Select the modality and then select preset to be edited from the displayed list of preset names 2 Click on the 3 The Presets Dialog opens 4 Change the Window width and Level and clic
100. rs Application Settings Select User Admin Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition DICOM Server Users Storage Management Username Role jemailaddress CS DefaultUser DefaultUser Admin Administrator rk Technician rk Now to add a new user Click on the Add button which will be followed by a User Details Dialog 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 73 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Password Confirm Password Role E Mail Filter Search Results Group Ele C Modality oo08 0060 C Institution Name 0008 0080 M Department Na 0008 1040 C Performing Phy 0008 1050 l Reading Phwcirian ANNA 1040 Save Cancel Enter the user name password with confirmation role i e either doctor or technician and email ID of the user Select Filter Search Results that the user is allowed to view For Example if you want the user to view only the studies performed by specific referral physician then check the Referral Physician Checkbox and specify the name of the referral physician whom the user is allowed to view Enter Value You can choose multiple filter options if required Then click the Save button Note The password field is case sensitive To edit the user details Click on the Edit button and make the required changes in
101. ry name CATELLA WORKSTATION Category Name Cancel Clicking on the Delete button deletes the selected category name from the list 9 2 Design Report Template To design a report Template Click on the button in the CATELLA PACS 5 0 Viewer Screen and choose the Reporting Tab in the Application Settings Dialog shown below A dialog displaying all the predefined report templates will be displayed as shown below Application Settings Select User Admin Change Preference Password Administrator General Modality Annotations Filters Distribution Acquisition p Template Name a MRI CERVICAL SPINE m CERVICAL SPINE ABDOMEN SHOULDER Abdomen Male Early Pregnancy r Header Designer Category List Click on the Add button in the Reporting Dialog shown in the previous page which will be followed by a screen as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 108 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual g x Report Templates SAMME Mh a a gt Template cT ABDOMEN Modality Category None Public COOOCOAOCHOCECCADA eee l CT ABDOMEN After a imi APT of abdomen was studied thr a series of axial sections of 10 mm thickness from high di to the level of i Arter AE Lopogram of abdomen was studied Senes mm Uuckness rom up to he level oF Portal vein and porta hepatis are normal Portal and
102. s use the control key in the keyboard 4 All the nodes that you have added using the DICOM Settings will be listed out here 4 1 20 Play Frames To play all the frames of the selected series in a loop click i button and a Cine dialog pops up Now select the playing speed as slow normal or fast And then click the Play button a To stop playing click the Stop button Slow Mormal Fast 4 1 21 Linear Measurement The Linear Measurement Functionality of the CATELLA PACS 5 0 Viewer Software helps you to measure the length of the desired part of the image in mm To do this click M7 button in the Image Review Window and drag the mouse to draw a line from the desired point of start and end on the image You will notice a line with its length displayed on the image as shown below 0i 49Y E DR S K RAJAN NIZAMUDEEN D AMR me 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 35 lt lt A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ ee Please note the measurement details will appear in the default color and font Refer toAnnotation settings to set the default measurement settings To change the default line color settings and the location of the measurement line double click the measurement line A Set Properties dialog as shown below will open Location and Size Left Top j width Height Line Settings Line Color O00000 Line Width Line Style Solid Line
103. s Dialog An Administrator Settings Dialog will open 8 1 1 DICOM Server Settings This option of the CATELLA PACS 5 0 Viewer Application helps you to carryout the DICOM Server Settings and also allows you to add edit delete the DICOM Nodes and DICOM Printers The DICOM settings have to be done before you start using the software On clicking the DICOM tab in the CATELLA PACS 5 0 Viewer Application Settings Dialog a DICOM Settings Dialog appears Application Settings x Select User Change Preference Password Administrator Annotations Reporting Distribution Acquisition DICOM Server Storage Management Router Rules Hospital Name AMD HOSPITAL AE Title ane Port Study Timeout 30 F secs L n B View Current Log Service is running oan ooe ATLSRVR DBELEZE 1111 192 168 DBLAZE 104 localhost tst 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 69 as A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual l The fields in the DICOM Settings Dialog and their descriptions are listed below Hospital Name Enter the name of the Hospital or the imaging center AE Title Specify Application entity AE title of the CATELLA PACS 5 0 Viewer DICOM Port Enter the DICOM Port Number Study Timeout Suspends the retrieval of the studies from the remote node when no data is received from the remote node for a specific time peri
104. s annotation tools available in the Image Stitching Window Once you have done the required processing click on the Stitch button You will notice that a new image is being added to the current image series Series layout MOH 4 1 26 Mark as key Image This option of the viewer helps you to mark the important images of the currently opened series as key image for future reference report preparation etc To do this select the required image in the Image Review Window and right click and choose Mark as Key Image Note 1 Clicking on the Open Key Image button in the Archival Screen lists all the key images that you marked in the Archival Screen 3 Right clicking the marked key image and choosing Unmark Key Images Options unmarks the selected key image 4 4 1 27 Hanging Protocol The Hanging Protocol indicates the set of rules defining the way you would like to arrange the different images series of a specific study type on your computer screen or monitor either one or more monitors Configure Hanging Protocol Double click the desired study in the Archival Screen or choose a study and click on the Open Study button or right click the required study and select open study You will notice that the selected study opens in the Image Review Window as shown below 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 40 A D ____ ee AMD Technologies Inc Catella 5 0 PACS Viewer User Manual aLL IM
105. saaseeeeeeeseangeeees 31 4 1 13 View DICOM Attributes To view the DICOM Attributes of the selected image s sssssnnnnnnnssssessssrrrrnnrrrrrrrreesssrnrrnnrrrnnene 32 4 1214 Export Image to desired storage OGAN ON cvisincssxecinaaexrapnanncecinasceanbnaesactnaascawbrasnsesinn aserincadaecinau Sidi earan Ek Tari renari i 32 4 1 15 Expor Images aS POWSIDOINN sesackcananntisantencncarenattioavtesntsarnattieaneentreuuenatieanqesnteavenntieanwer aren uenettemwnnnieauanttemnwennerreeatereentes 33 esas SOE FW INGA SS csc serene ep ace E tae sacede ap eeceeaeasa sada E E E E E E E 33 ARTA erea AY WMC era N E E lenmeneeetiaan 34 We CR O E E E eee 34 4 1 19 Send Images to Remote NOde ccccsssssssssssseceeeeececeeeneaeeesseeeeeeeeeeeeeeeeeaaeaasaqeeeeeeeeeeeeseeeeaaaasdeceeeeeeeeeeseseeenaaassseseeseeeees 35 EN Fay UNS ea SSR a 35 n E a e E E TE PEE A AEE A A EEE ee eee eer 35 Asses Areg INSASUNCIIICILS secerneren Ee AEAEE EAEra Ea Aaaa 36 A T23 Angular MGASUFEING INS esie oes E E E E eee 37 AoW MMA O FIN a E E A E E E 38 4 1 25 Apply Window Level PreSetS ssisrcsricncncisiinniesiis ere ier ern a eerie ene aE re eres ere eee eer ee eee 38 tle O ed NCTA E S E S E E E E E tears eceesanteatecen ao E EE EE E E oleae eee cee 39 A20 Mark d9 Koy IMA erea E ee ee eee ee eer Tr 40 Wed Fn POCI eses e eE R 40 4 1 28 Digital Subtraction Angiography DSA ccoscneeretssdckatiaesoretitiienketeedearetauideslebseeeouatlid extsicedearstaitlootessdeenatlciectec
106. sedearecledeatectudeauts 42 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 2 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Ale Daa E P E lal aa A E E E AA E E 43 Ee E aE E E E E E E EE EE E E A N E E E E 43 TEPIC OTO F NEON A N E E a T SA 44 6 1 Write Selected Studies onto a CD DVD cccccccccccsscsscessssseeeeeeeeeeceseecesccassssseeseneeeeeessenseccoasssseeeeeeeeeeeseseesecosseseeeeneeeeesessesaes 48 7 1 Getting Familiar with the Image Acquisition Module ccccccseeeeeeeeeceeeeceeeeeeeceaaeaaeeeeeceaaaaaeeeeeseeaeaeeeeeeesaaaeeeeesessaageeeeessssaeees 50 7 2 Add Fatent aie faiicli o de een ee eee EEEa ETERNE Tee an eee en ee E aE 51 Po 8 1 FPO DICOM NVE a a E cman SE nn EA EEN AE OE A ovr eter fie O E aoe eT ee 52 Lar Query rom Modal Workisi SOTV GE aiceicteacacssieverctsanececsexeesdegasdeniesenecedsavnseecd dynes ARENE En SEEE EEES E 52 720 AMPOME Non DICOM Mage FCS aioin r EAN rE Eao EEE E E ea 53 7 6 Capture Live Video Single Frame IMagQe ccccccccccccccesseeeeeeeeeeeeeeeeeeeeeeeaaaeesceeeeeeeeeeeeeeeeeeaeaeaaaueeeeeeeeeeseeeeesaaaaaesaeeeeeeeeeeeseeensaas 54 AEE EE E EEEE E eer AA A A E N OIEA A NE E AOE E ee E N E E ET 55 E a EE i EEE AA A A AAE EEEN A EAE E EA E NE ET OE EEE EE ET 56 7 8 1 Set Film Scanner Properties ease casinesisncianesswciainswtoncaaneteanisalyts ENEA AERAR ARANE E AARNE AEAN E AEEA NERA EARRA HEARRE EAEAN AHHAA 57 PBZ HOW OR EE TMM AE E EE A A E
107. splayed only if you enabled the Display Thumbnails Option in the General Settings You can open the report by right clicking on a study in the tree view and selecting the View Report option The following table gives a quick overview of all the annotation tools available in CATELLA PACS 5 0 Viewer icon Option Click To Edit Options l Get the mouse pointer or to deselect the UE Selection Tool selected annotation tool 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 22 ease A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Rotate Left Rotate the image to the left Rotate Right Rotate the image to the right Flip Horizontally Flip the image horizontally i az Flip Vertically Flip the image vertically Display Options D Window Leveling View the window width and level of the image Bo o Hounsfield View Hounsfield value of the image Adustimade Adjust sharpness enhancement window l g width and level of the image Plots the number of pixels in the image Image Histogram vertical axis with a particular brightness value horizontal axis Annotation Options h Draw a line on the image Draw an arrow on the image Rectangle Draw a rectangle on the image Ellipse Draw an Ellipse on the image Free Hand Tool Draw free hand polygonal shape Save annotations that you have made on the ave image Navigation Options Removes the image from the pending Study Complete worklist If the user cho
108. t etc Deleted Enabling this shows the list of all deleted jobs Cancelled Display Jobs Completed in Past Days Edit box Display Jobs in Error in Past Days Edit box Display Jobs Deleted in Past Days Edit box Display Jobs Cancelled in Past Days Edit box days specified by you 8 6 7 Image Acquisition Settings Checking this displays the list of all jobs whose process is cancelled by administrator The application will display all the jobs that are completed in past n number of days that you have entered here Based on the number n entered here the list of all the jobs whose burning process is intervened in the past n number of days will be displayed in the Queue Status Window Displays all the jobs that are deleted in past n number of days specified in this edit box Displays all the jobs whose burning process is cancelled in past n number of This option of the application helps you to carry out various settings for the image acquisition module of the CATELLA PACS 5 0 Viewer To do this click on the Acquisition Tab in the Settings Dialog of the application 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 103 AMD Technologies Inc Catella 5 0 PACS Viewer User Manual aD Application Settings Select User Admin 7 Change Preference Password Administrator General Modality Annotations Filters Reporting Distribution Acquisition Default Institution Sett
109. t an Annotation WOON era siyacceacecactetarpncacesenacsnencersca cae nanena EEA EEE EEEE EARE 25 Ale ZOM and Pan IMAGO esse an SER icara ieS EAN a Erara na Eaa ii 25 4 1 3 Rotate Flip and Invert IMAG S cca ctinsecanseatioarsienenaaresinatsenetectnsareenatienveinnasennematieanqeenieonenatiennGienspensanatnensGronseeueentierGenmppawontnenGentte 26 4 1 4 Reset Level and Orientation of image ccccccccccccceceaneeseeeeeeeeeeeeeeeeeeeaaaaessdeeeeeeeeeeeeeeeeaaaaaaadeeeeeeceseeeeseeesaaaasegaeeeeseeees 27 4 1 5 Change Window width and level csicis siinccscoviusiveesintivosvivcssicesivcratedantisdevandsaondddtasoeusadasdetiattsosaatevestid esonvanduadedtssivesceadidesvidies 27 4 1 6 View Hounstield OF ACS ci cias tip ciontte rscathacerncasneuiecenatenscandoen sea ueamenoneessumanebinicendeatuae EEA a EEEE E 27 A RON ONAN geese ae eeepc let rae earth tet tari atl ta poesia A AON EE E 28 A T8 INCIUGES texton TAC IMAG E assena sissies ques ootedveseittnesdancsdvernctuausxaciiayixedd tauntessad EA eNe eai wee ARENE T on EA ESENS EENET 29 4 1 9 Adjust the Display Parameters of the image ccecceseceeeeeeeeeeceaeeeeeeaaaeeeeeaaaeeessaaaeeessaaaeeessaaaeeessaaaeeesseaaeeeseeaaeeeeeaaneeeens 30 4110 DICCON OVETIAYS rers eaae RR EEE EREEREER RERET 31 ATi Change Image per Daga eisai or E EAEE EA EE 31 4 1 12 Send the selected image to a Print COMPOSE cccccceeeeeeeeecceeeeseeeeeeeeaeasceeeeeeeaaeaaeeeeeeesaeaaeeeeeseesaaaeeeeees
110. t the page options for printing using the Page setup window To Prepare a Report 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 111 n A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Select the desired Report Layout from the New Report button The report layouts available are Report only Report with images at side and top and only images 1 2 4 6 per page The report layout including the predefined Report Header will be displayed in the Reporting Area as shown below CEDC N Ei Na IMAGE VIEWER KAULUS fen a8 ETO AP Scout Images At Side CT CERVICAL SPINE Page Setup Prin NIZA MUDEEN D A MRA DAS KRAJAN AP Fil He 10mm 1 SiCT iat Pe TN EAF WAF LAS l RNAI CEEE Md ll dd ll eee rr 5 1 AMD Technologies Inc 218 Bronwood Avenue Wa Los Angeles CA 90049 USA ms Road Alwarpet Chennai Patient Name NIZAMUDEEN D A MR sdfds fds f Patient ID DR S K RAJAN Study Date 16 Dec O4sdf sdf sdf sdf Study Description CHEST CT OF CERVICAL SPINE After a preliminary lateral Topogram Cervical spine was studied through a series of axial sections of mm thickness from the level of foramina magnum to C7 Findings Loss of normal cervical lordosis noted probably due to muscle spasm Foramina magnum Atlanto Axial Articulation and Aflanto occipital articulation are normal Cervical vertebral bodies them lamina pedicles s
111. te 12 16 2004 0022 Acquisition Date 12 16 2004 0023 Image Date 12 16 2004 0030 Study Time 12 35 13 PM 0031 Series Time 12 35 58 PM 0032 Acquisition Time 12 36 14 PM 0033 Image Time 12 36 19 PM 0050 Accession Number 5377 0060 Modality CT p070 Manufacturer GE MEDICAL SYSTEMS 0080 Institution Name PRECISION DIAGNOSTICS P 0090 Referring Physician s NULL 1010 Station Name CT 1030 Study Description CHEST 103E Series Description He 10 mm 1 5 4 1 14 Export Image to desired storage location To export the image to a desired storage location 1 Select the desired image in the Image Review Region 2 Click Fea Button 3 A Select Destination Dialog opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 32 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual oe EN gt Program Files 86 gt Ashva Technologies Pwt Ltd fq COViewer 4 Data Ca Dictonary C Images C License 4 Logs ae Target Drive c Output Format JPEG Files Cancel 4 Select the Target Drive and Output Format and Click on the OK Button 4 1 15 Export Images as Powerpoint To export the selected image to an existing Powerpoint presentation file or a new presentation file 1 Select the images right click and choose Export images as Powerpoint 2 A Presentation dialog will appear Presentations _ New Presentation Insert Into File 3 Click on New Presentation to export
112. ted cell accordingly 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 44 ey A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T To merge the adjacent cells right left upper and lower cells right click and select Merge with Right Left Upper Lower Cells from the Pop Up as shown below Clicking on the Save Layout button will save the user defined print layout as a new layout Please note selecting a new print layout will delete all the selected images from the Print Composer Window mea CEREA PRINT COMPOSER Ca iat pn Toer Navigate HAA Page 5 5 Import DICOM file Split cell horizontally Split cell vertically Orientation B Print Options Copies e Remove DICOM file Reset Level and Orientation Page Options Print Range Customize hot keys Oall current Page Page Number To You can import required DICOM images to empty cells of the print composer window by right clicking and selecting Import DICOM File A Browse For Folder Dialog will pop up on your screen Then locate the desired DICOM Files and click OK Right clicking and selecting Remove DICOM File will remove the DICOM image from the particular cell Tools If required you can zoom in or out the images in the desired cells of the Print Layout Window by ath clicking on this button and left clicking and dragging the mouse over the image To pan M C the zoomed image right click and drag
113. tient Name that you have specified in the CD label file in the Caption Edit box Select the corresponding value and click OK button 7 To add other merge fields select the Study1 label in the Fields List Panel in the Media CD Labels dialog and repeat the 3rd and 4th steps 8 To edit the merge field names and its value select the merge field name and click Edit button in the Media CD Labels dialog Make the required changes in the Label Dialog and click OK button 9 To delete the merge field name select the required merge field name and click Delete button in the Media CD Labels dialog shown above 10 To delete the Study select the appropriate study say for example Study1 from the Fields List Panel and click on the Delete Group button To edit or change the CD Label File List Select the Label name from the displayed list and click the Edit button in the Label File List Panel A DUET Label File Dialog opens Make the required changes in the description and filename and click OK button Note The default label s description cannot be edited To delete the CD Label File from the List Select the Label name from the displayed list and click Delete button A Confirm Dialog as shown below will open Click Yes to continue Catella Workstation Confirm delete Mo 8 6 5 Anonymization Settings 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 101 ease A D AMD Technologies Inc Catella 5 0 PACS Viewer Use
114. tigure RIMAGE Tor CD DV DWANG veretsricssocssceseecsswcanoceaveseedscuecuvancisentewicaqeaveuseleaveisein TAE a EEOSE 91 8 6 3 Config re PRIMERA for CD DVD Writing ic cctcccseeececcceeeteccesvetesaeeuteccedvctescceeedeueesuedesacteudcncedeqterccseedeueesvadesacteutenesdecdencceeedentys 95 8 6 4 Contig ure DUET for CD DVD UTM etc cietee Sense oee ieee ats Barge snschoteese coe oc eA ees ate EENE E EE EERE 99 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 3 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual B69 OMY il a GIG gt or E N A E E AEE EA AE 101 Bs OPIS lea Opon ei Ses wae oE E EEEE EEE EE E E EE 102 8 6 7 imaga ACQUISITION SEWN essiensa sira r ipa EE A RR SEE EP RD ERAR RO EPa a iea EER e ariera 103 B27 l Delault MSO SE UINGS sersa E a E E 104 om ey HOW O Relanmal PIY SiCIaAN serpan a e ee E 104 BT DICOM GONGSO E A E E E N 105 GA Vaod Capui a oN n S E E ee A 105 Ero FON e O a S S ee 105 8 8 5 HOW to set Password for Preference SCOGGIN cssirriccreniisreti s Ensen raei Eai NPE n EEEO ESOR N Orre EEEE Ei 105 21 Categorize Report T CMPIANSS serin E S A 107 92 DESA REPON TOMDA arain a e ai a tr Teer mer tere dara rr Tre 108 93 How 10 design anew Report Heador i scises ce ice svete rtecte cts Teee aeir SA sv VESE SENA naaa cies tenes sence ETEESI TaS 109 9 4 ROpOninNg PVOCCGUNS x ixcrcncxincasacacued n a a EEE EA E AAA AEE 111 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 4 aay A D AMD
115. top __ 1 2 840 113619 2 81 290 26072 5377 2 4 2 p _ 1 2 840 113619 2 81 290 26072 5377 2 5 2 1 2 840 113619 2 81 290 26072 5377 2 6 2 Sangesiha 1 2 840 113619 2 81 290 26072 5377 2 7 2 A _ 1 2 840 113619 2 81 290 26072 5377 2 8 2 Computer _ 1 2 840 113619 2 81 290 26072 5377 2 9 2 ax _ 1 2 840 113619 2 81 290 26072 5377 2 10 i _ 1 2 840 113619 2 81 290 26072 5377 2 11 Network _ 1 2 840 113619 2 81 290 26072 5377 2 12 _ 1 2 840 113619 2 81 290 26072 5377 2 13 File name 290 i ET Files of type DICOM Fies o o Cancel The selected file will open in the Image Viewer Window as shown below Double click on the image and carry out various annotations using the available annotation tools Refer image review section for details CEN ACE Viewer CIEI CIA E E BOS ESSER CGOOEO oazann e cS ol SDE NE HEORED SBABEEH A 572672010 Abdomen 10 B4is Imager 1 1 RT RT_Abdomen Adult KMIO BANGALORE RANGALAKSHMI 45Y F srna MILLI EES IEE 3 3 Load DICOMDIR To load a DICOMDIR to the CATELLA PACS 5 0 Viewer Application click on the DICOM Directory button and select the DICOMDIR File which you would like to load from an Open Dialog 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 11 CEN A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual __ You will notice that all the images corresponding to the selected DICOMDIR will be displayed
116. ts the selected image s from the page and puts in the clipboard To paste the image from the clipboard right click and choose Page Options gt Paste If you wish to clear the images in the clipboard right click and choose Clear Cached images Right clicking the image and choosing Page Option gt Reposition image repositions the images in all pages 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 46 aay A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual T Printer Options Now select the film size on which you want to print the images and then select the film orientation either as Portrait or Landscape The names of all the DICOM Printers or the Network printers connected to your machine will be listed out in the Select Printer combo box Select the appropriate printer name Select the number of copies you want to print and the print range After carrying out the required print settings click on the Print Button to print the images Note 1 Orientation indicates how the images are positioned on the page Portrait orients the print vertically while landscape orients the print horizontally 2 The displayed view is the Print Preview view insuring that you have selected the correct images before the printing operation You can use the Clear Button to clear all the images in the Print Composer Window 3 Right Clicking and selecting Customize Hot Keys enables you to customize the shortcut keys for the vari
117. tton to check whether the connection with that node is successful or not To edit the DICOM Node 1 Select the DICOM Node to be edited from the displayed list 2 Click the button in the Remote DICOM Server Frame of the DICOM Settings Dialog 3 The DICOM Node Settings dialog opens 4 Make the necessary changes and click on the OK Button The AE Title Name is restricted from editing To delete DICOM Node 1 Select the DICOM node to be deleted from the displayed list 2 Click on the button in the Remote DICOM Server Frame of the DICOM Settings Dialog 2 A Confirm Dialog opens Click on the OK Button to continue 8 1 1 b How to Add Edit Delete DICOM Printer Settings To add a new DICOM Printer 1 Click on the f button in the DICOM Printer Frame of the DICOM Settings Dialog 2 ADICOM Printer Settings Dialog opens 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 71 AD AMD Technologies Inc Catella 5 0 PACS Viewer User Manual AE Title Hostname Port Description Orientation LANDSCAPE Film Size SINK1OIN Destination BIN 1 Magnification Default Layout Priority Medium Save Cancel 3 Specify the Application Entity AE Title Hostname Port and Description of the DICOM Printer in the corresponding edit boxes 4 Then select the default orientation destination film size magnification and print layout for the DICOM Printer 5 Select the priority medium a
118. tyle To select the default line style To make the fill color transparent Fill color To set the default fill color for the rectangle and ellipse drawn on the image Fill Style To set the default fill style for the rectangle and ellipse drawn on the image Note To allow the images to see through the background of the annotation set the fill style as Clear To set the default font of the text included on the image Measurement To set the font for measurement option Font Apply To Save the settings 8 5 Filter Settings This feature enables to add edit delete search filters On clicking the Filter Tab in the CATELLA PACS 5 0 Viewer Application Settings Dialog the Application Settings Dialog with the options to add edit and delete filters will open 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 88 Sn A D AMD Technologies Inc _ m Application Settings Select User Admin To Add Search Filter Settings Catella 5 0 PACS Viewer User Manual On clicking the button in the Filter Settings Dialog a Search Filter Dialog as shown below opens Specify the filter name and other required details and click on the OK button Fiter Name Fiter Description Patient Name Patient ID DEX Study Date Span Modality cT soesson namer sd Study Desc Referring Physician nssusonneme OOOO Report Status QueryType Local Archive Set As Default a 2010 AM
119. y a Font Dialog as shown below Change the font name style size and color if required and click on the OK button Arial Rounded MT Bok O Arial Unicode MS Baskerville Old Face O Batang r Effects Strikeout Underline Color 4 1 9 Adjust the Display Parameters of the image This option of the CATELLA PACS 5 0 Viewer helps you to change the display parameters such as the sharpness window width and level and the enhancement values of the image T o do this click the a button in the Image Review window or right click and select Processing gt Adjust Image from the Pop Up An Adjust Image Dialog as shown below will pop up on your screen as shown below Next change the required parameters and click ok 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 30 ease A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual ____ ee Enhancement Lalit tt ttittttttittti Sa O O O a S O OS O O S J It Apply Window Level PAA ga 4 1 10 DICOM Overlays To display hide DICOM overlays like measurement scales values etc on the image Click D button Or Right click on the Image and select Processing gt Display Overlays from the Pop Up To apply preset DICOM Overlay Template to the image Right Click on the image and choose Overlays and then desired overlay template name Please note all the preset overlay templates correspo
120. y fields In case you want to display an image series corresponding to a study that was conducted prior to the currently loaded study in the layout enable the Prior checkbox and choose the prior number 2010 AMD Technologies Inc Doc 340 3 503 Rev 01 Page 41 ant A D AMD Technologies Inc Catella 5 0 PACS Viewer User Manual Note 1 For example if you choose prior as 2 then the image series corresponding to the study that is conducted two times earlier than the currently loaded study will be displayed in the selected layout 2 If you would like to load only the current study in the selected layout leave the Prior Checkbox unchecked Specify the window width and level in which you would like to display the images and choose the number of rows and columns for the series layout of the Image Review Window Select the Invert Option if you like to invert the images Finally click on the Save button Note The Modality type Study Description and Series Description are mandatory fields Then right click and choose Hanging Protocol gt Save to save the hanging protocol An Enter Caption Dialog opens Enter the Protocol Name and click OK button Enter Caption Cancel Repeat the above steps to configure the hanging protocol for other image series of the study Note Right clicking and selecting Hanging Protocol gt Save As saves the hanging protocol as a new protocol for the study Right clicking and choosing Hangi